首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Intracloud (IC) and cloud-to-ground (CG) lightning flashes produce transient changes in the electric field (E) above a thundercloud which drive transient currents in the global electric circuit (GEC). Using in-cloud and above-cloud E data from balloons, ground-based E data, and Lightning Mapping Array data, the above-cloud charge transfers due to lightning transients are estimated for five IC and five CG flashes from four thunderstorms that occurred above the mountains in New Mexico, USA, in 1999. For the five CG flashes (which transferred − 4 to − 13 C to the ground), the transient currents moved + 1 to + 5 C of charge upward from cloudtop toward the ionosphere, with an average transient charge transfer of about 35% of the charge transferred to ground. For the five IC flashes (which neutralized 6 to 21 C inside the cloud), the transient currents moved − 0.7 to − 3 C upward, with an average transient charge transfer of about 12% of the lightning charge. Estimates for three thunderstorms indicate that the transient currents made only a small GEC contribution compared to the quasi-stationary Wilson currents because of the offsetting effects of IC and CG flashes in these storms. However, storms with extreme characteristics, such as high flash rates or predominance of one flash type, may make a significant GEC contribution via lightning transients.  相似文献   

2.
The global electrical circuit, which maintains a potential of about 280 kV between the earth and the ionosphere, is thought to be driven mainly by thunderstorms and lightning. However, very few in situ measurements of electrical current above thunderstorms have been successfully obtained. In this paper, we present dc to very low frequency electric fields and atmospheric conductivity measured in the stratosphere (30–35 km altitude) above an active thunderstorm in southeastern Brazil. From these measurements, we estimate the mean quasi-static conduction current during the storm period to be 2.5 ± 1.25 A. Additionally, we examine the transient conduction currents following a large positive cloud-to-ground (+ CG) lightning flash and typical − CG flashes. We find that the majority of the total current is attributed to the quasi-static thundercloud charge, rather than lightning, which supports the classical Wilson model for the global electrical circuit.  相似文献   

3.
This paper is focused on the study of rainfall yield characteristics of electrical storms observed over the Northern Iberian Peninsula during 1992–1996. To this aim Principal Components Analysis (PCA) and Self-Organizing Maps (SOM) method have been used. The SOM method is a group of artificial neural networks based on the topological properties of the human brain. Results clearly suggest that there exist three different meteorological patterns that are linked to the characteristics of electrical events found in the study area. In winter, most of the electrical events are formed under oceanic advection (NW air fluxes). On these cases, mean rainfall yield estimates reach values of 700 104 m3 per cloud to ground lightning flash (CG flash). During summer most frequent electrical storms are associated to local instability shooting by surface heating with advection of humidity coming from the Iberian Peninsula. Under these meteorological situations, rain is scarcer if compared with oceanic events but lightning CG counts reach the maximum values found in the area (about 10 CG counts per 20 × 20 km2 and day) giving this way the smallest rainfall yield with a mean value of 15 104 m3 per CG flash. Iberian air fluxes associated with cold air in upper parts of the atmosphere represent the third meteorological pattern found. This pattern is most common in spring and autumn but is not unusual in the rest of the seasons. In those cases mean rainfall yield in the area is about 150 104 m3 per CG flash. In all electrical episodes K instability index is greater than 15 °C but in the most lightning producing events, this index reaches in the area values greater than 24 °C. PCA results pointed out that there exists a relationship between rain and CG counts expressed by the first principal component computed from standardized data. However, we must notice that no event is solely linked to this axis, since a seasonal influence which decreases lightning production when rain increases is always present. Results found are of great interest for short term forecasting of flashfloods in mountainous areas like the Spanish Basque Country region.  相似文献   

4.
Using a high-speed camera system and two electric field antenna systems, we have documented the initial processes of an altitude-triggered negative lightning (ATNL). The optical records clearly show that ATNL begins with the inception and propagation of an upward positive leader (UPL) and then a simultaneous propagation of UPL and downward negative leader (DNL), known as the bidirectional leader process, follows. Based on the optical records, it is inferred that (1) the triggering height is about 371 m; (2) the two-dimensional (2D) propagation speed of the UPL in its inception phase is about 3.8–5.5 × 104 m s− 1 during its propagation from about 393 to 452 m above the ground; (3) the grey levels of the DNL are about one order of magnitude higher than that of the UPL in their inception phase; (4) a discharge phenomenon propagating along the elevated triggering wire part of the lightning channel occurs after the mini-return stroke (MRS), with a 2D propagation speed of about 1.6–2.0 × 105 m s− 1. Combined with the simultaneous electric field change records, it is further inferred that (1) the UPL incepts about 932 μs earlier than the unstable DNL and about 4.1 ms earlier than the stable DNL; (2) the unstable DNL propagates downward intermittently three times with a time interval of about 1 ms, and each propagation contains a different number of steps with an average step length of about 7 m; (3) the stable DNL incepts at the tip of the unstable one, with a 2D propagation speed of about 1.9 × 105 m s− 1, an average step length of about 3 m, and a stepping time interval varying from 6 to 31 µs with a mean value of 15 µs.  相似文献   

5.
Using high-speed cameras, we have recorded the leaders contained in four natural negative cloud-to-ground (CG) lightning flashes in the summers of 2006 and 2007 at Conghua, Guangdong, China. It was found that the downward negative leaders preceding the first return stroke could propagate at quite different speeds. In one flash, the average speed of the downward negative stepped leader with no branches is about 2.2 × 106 m s− 1, while that of the other 3 flashes are all of the order of 105 m s− 1 with multilevel branches. The luminosity of the leaders shows an increasing tendency in propagating downward to the ground. For the leaders preceding the subsequent strokes, although all of them exhibit high speeds as reported previously. One subsequent leader exhibits an increasing speed from 5.2 × 105 m s− 1 to 1.7 × 106 m s− 1 during its propagation from about 1.26 to 0.36 km above the ground, and its luminosity also increased. The speed and luminosity of a leader between subsequent strokes of a natural lightning appear to decrease as it developed downward. Its speed ranges from 1.1 × 106 to 1.1 × 105 m s− 1, with a height between 1.15 and 0.81 km above the ground.  相似文献   

6.
Study of the total lightning activity in a hailstorm   总被引:1,自引:0,他引:1  
A thunderstorm that developed over northeastern Spain on 16 June 2006 is analyzed. This severe thunderstorm produced hailstones as large as 40 mm and had a lifetime of 3 h and 30 min. Radar cross-sections show strong vertical development with cloud echo tops reaching an altitude of 13 km. The specific characteristics of the lightning activity of this storm were: (i) a large amount (81%) of negative cloud-to-ground (−CG) flashes with very low peak currents (< 10 kA in absolute value), (ii) a very large proportion of intra-cloud (IC) flashes with an IC/CG ratio reaching about 400, (iii) a large number of “short” IC flashes (with only 1-VHF source according to SAFIR detection), (iv) a large increase of the −CG flash rate and of the CG proportion near the end of the storm. The rate of −CG flashes with a low peak current were observed to evolve similarly to the rates of IC flashes. Most of them have been assumed to be IC flashes misclassified by the Spanish Lightning Detection Network (SLDN). They have been filtered as it is usually done for misclassified +CG flashes. After this filtering, CG flash rates remained very low (< 1 min− 1) with +CG flashes sometimes dominant. All the particular lightning activity characteristics similar to those observed in the Severe Thunderstorm Electrification and Precipitation Study (STEPS) campaigns support the hypothesis that this thunderstorm could have had an inverted-polarity or complex charge structure. The maximum IC flash rate (67 min− 1) peaked 24 min before the presence of reflectivity higher than 60 dBZ. The IC activity abruptly decreased during the period when reflectivity was dramatically increasing. The time of maximum reflectivity observed by radar was consistent with the times of reported hail at the ground.  相似文献   

7.
In October 7–9, 2016, Hurricane Matthew moved along the southeastern coast of the U.S., causing major flooding and significant damage, even to locations farther north well away from the storm’s winds. Various observations, such as tide gauge data, cable measurements of the Florida Current (FC) transport, satellite altimeter data and high-frequency radar data, were analyzed to evaluate the impact of the storm. The data show a dramatic decline in the FC flow and increased coastal sea level along the U.S. coast. Weakening of the Gulf Stream (GS) downstream from the storm’s area contributed to high coastal sea levels farther north. Analyses of simulations of an operational hurricane-ocean coupled model reveal the disruption that the hurricane caused to the GS flow, including a decline in transport of ∼20 Sv (1 Sv = 106 m3 s−1). In comparison, the observed FC reached a maximum transport of ∼40 Sv before the storm on September 10 and a minimum of ∼20 Sv after the storm on October 12. The hurricane impacts both the geostrophic part of the GS and the wind-driven currents, generating inertial oscillations with velocities of up to ±1 m s−1. Analysis of the observed FC transport since 1982 indicated that the magnitude of the current weakening in October 2016 was quite rare (outside 3 standard deviations from the mean). Such a large FC weakening in the past occurred more often in October and November, but is extremely rare in June-August. Similar impacts on the FC from past tropical storms and hurricanes suggest that storms may contribute to seasonal and interannual variations in the FC. The results also demonstrated the extended range of coastal impacts that remote storms can cause through their influence on ocean currents.  相似文献   

8.
During the summers of 2003 to 2006 sprites were observed over thunderstorms in France by cameras on mountain tops in Southern France. The observations were part of a larger coordinated effort, the EuroSprite campaigns, with data collected simultaneously from other sources including the French radar network for precipitation structure, Meteosat with images of cloud top temperature and the Météorage network for detection of cloud-to-ground (CG) flash activity. In this paper two storms are analyzed, each producing 27 sprite events. Both storms were identified as Mesoscale Convective Systems (MCS) with a trailing stratiform configuration (ST) and reaching a maximum cloud area of ~ 120,000 km2. Most of the sprites were produced while the stratiform area was clearly developed and during periods of substantial increase of rainfall in regions with radar reflectivity between 30 and 40 dBZ. The sprite-producing periods followed a maximum in the CG lightning activity and were characterized by a low CG flash rate with a high proportion of + CG flashes, typically around 50%. All sprites were associated with + CGs except one which was observed after a − CG as detected by the Météorage network. This − CG was estimated to have − 800 C km charge moment change. The peak current of sprite-producing + CG (SP + CG) flashes was twice the average value of + CGs and close to 60 kA with little variation between the periods of sprite activity. The SP + CG flashes were further characterized by short time intervals before a subsequent CG flash (median value < 0.5 s) and with clusters of several CG flashes which suggest that SP + CG flashes often are part of multi-CG flash processes. One case of a lightning process associated with a sprite consisted of 7 CG flashes.  相似文献   

9.
To further investigate the influence of cloud base temperature, updraft velocity and precipitation particle constitution on cloud electrification, five thunderstorms in various regions of China were simulated by using the three-dimensional compressible hailstorm numerical model including inductive and non-inductive charging mechanisms. The results indicate that changes of cloud base temperature have an influence on the initial electrification. Comparison of the above cases shows that in the case of warm cloud base and moderate updraft velocity (< 20 m s−  1), active electrification occurred below the − 10 °C level before moving upward to the − 20 °C level. In contrast, when cloud base is cold and updraft velocity is intensive, the main charging region is at the − 20 °C or even higher level. In that case, the vertical extent of the main negative charge region becomes larger with the increase of cloud base temperature. Apart from the main dipolar or tripolar charge structure, some smaller charge regions with relatively high values of charge density may also appear. Frozen drops, originating mainly from supercooled raindrops, mainly get electrified through charging interactions with snow at or below the − 20 °C level. They are responsible for the negative charge region near the melting level at the initial stage of precipitation if there is a large supercooled raindrop content. Non-inductive charging during hail-snow collisions is rather weak, resulting in the charge density on hail of no more than − 0.01 nC m− 3.  相似文献   

10.
Based on electric parameters measured in actual storms and considering that charges distribute along anaxisymmetric cylinder, in this paper the changing rates of vertical electric vorticity with time in shear and anvil stormsare calculated respectively, The results indicate that the changing rate of vertical electric vorticity with time caused byelectric field force is about 10~(-8)—10~(-7) / s~2 in shear storms. For stronger electrified clouds, it can reach 10~(-6)—10~(-5) /s~2 inlocal area and be almost matched with the action of dynamics. The magnitude is larger at storm bottom and decreaseswith height. The electric energy concentrates mainly in middle and low layers of a storm. The results are same as in anvilstorms, but the magnitude is an order smaller. Meanwhile, the results also indicate that the convective motion of chargedhydrometeor particles due to electric field force can form horizontal vortex of air current. The electric circulation is animportant factor.  相似文献   

11.
Balloon-borne electric field soundings and lightning mapping data have been analyzed for three of the storms that occurred in the Severe Thunderstorm Electrification and Precipitation Study field program in 2000 to determine if the storms had inverted-polarity electrical structures. The polarities of all or some of the vertically stacked charge regions in such storms are opposite to the polarities observed at comparable heights in normal storms. Analyses compared the charge structures inferred from electric field soundings in the storms with charges inferred from three-dimensional lightning mapping data. Charge structures were inferred from electric field profiles by combining the one-dimensional approximation of Gauss's law with additional information from three-dimensional patterns in the electric field vectors. The three different ways of inferring the charge structure in the storms were found to complement each other and to be consistent overall. Charge deposition by lightning possibly occurred and increased the charge complexity of one of the storms.Many of the cloud flashes in each case were inverted-polarity flashes. Two storms produced ground flash activity comprised predominantly of positive ground flashes. One storm, which was an isolated thunderstorm, produced inverted-polarity cloud flashes, but no flashes to ground. The positive and negative thunderstorm charge regions were found at altitudes where, respectively, negative and positive charge would be found in normal-polarity storms. Thus, we conclude that these storms had anomalous and inverted-polarity electrical structures. Collectively, these three cases (along with the limited cases in the refereed literature) provide additional evidence that thunderstorms can have inverted-polarity electrical structures.  相似文献   

12.
GPS-synchronized measurements of electric (E) field changes induced by lightning flashes were recorded at six stations in the northeastern verge of the Tibetan Plateau. The height and magnitude of charge neutralized by 65 return strokes, including 16 negative cloud-to-ground (CG) flashes and 2 positive CG flashes, have been fitted with the nonlinear least-square method based on the E field changes of CG flashes observed in a typical thunderstorm with larger-than-usual lower positive charge center (LPCC). Results show that the height of the charge region neutralized by negative CG flashes ranges from 3 km to 5 km above the ground, corresponding to an ambient temperature between − 2 °C and − 15 °C. For the two positive CG flashes, the neutralized charge regions are located at a height of about 5.5 km and the ambient temperature is about − 18 °C, indicating the existence of upper positive charge in the thunderstorm.  相似文献   

13.
By using a high-speed video camera system (1000 frames s− 1) in correlation with fast and slow antenna systems, the negative cloud-to-ground (CG) flashes that struck the ground with more than one termination have been analyzed. This kind of stroke, named as multiple-ground terminations stroke (MGTS), was produced by different branches of the same stepped leader during quite a short time. Based on optical images, the 2D progression speed of leader branches was estimated to be in the range (0.9–2.0) × 105 m s− 1. The distance between adjacent striking points of MGTS was from 0.2 km to 1.9 km. The percentage of flashes with multiple-ground terminations occupied about 15% (9 out of 59) of the total negative CG flashes, with a range of 11%–20% in different areas in China. The time intervals between the two adjacent peaks ranged from 4 μs to 486 μs based on the E-field change caused by the MGTS. The flashes which had multiple striking points on the ground during quite a short time may be a common phenomenon in the lightning discharge process. It might produce more serious damage to facilities on the ground and should not be neglected in the design of lightning protection.  相似文献   

14.
In July 2005, a field campaign was conducted in the Central Great Plains to obtain 60-field/s video imagery of lightning in correlation with reports from the U.S. National Lightning Detection Network (NLDN) and broadband electric field waveforms from the Los Alamos Sferic Array (LASA). A total of 342 GPS time-stamped cloud-to-ground (CG) flashes were recorded in 17 different sessions, and 311 (91%) of these were correlated with reports from the NLDN. Only 6 of the 17 recording sessions were dominated by flashes that lowered negative charge to ground, and 11 were dominated by positive CG flashes. A total of 103 flashes recorded on video were correlated with at least one NLDN report of negative CG strokes, 204 video flashes were correlated with one or two positive stroke reports, and 4 had bipolar reports. In this paper, we will give distributions of the estimated peak current, Ip, as reported by the NLDN, of negative and positive first strokes that were recorded on video, the multiplicity of strokes that were recorded on video, and the number of ground contacts per flash that were resolved on video. 41 (40%) of the negative flashes produced just a single-stroke on video, and 62 (60%) showed two or more strokes. The observed multiplicity of negative flashes averaged 2.83, which becomes about 3.14 after correcting for the finite time-resolution of the video camera. 195 (96%) of the positive flashes produced just a single-stroke on video, and 9 (4%) showed two strokes; therefore, the observed multiplicity of positive flashes averaged 1.04. Five out of 9 (56%) of the positive subsequent strokes re-illuminated a previous channel, and 4 out of 9 (44%) created a new ground contact. Simultaneous video, LASA, and NLDN measurements also allowed us to examine the classification of NLDN reports during 3 single-cell storms (one negative and two positive). Based on the LASA waveforms, a total of 204 out of 376 (54%) NLDN reports of CG strokes were determined to be for cloud pulses. The misclassified negative reports had |Ip| values ranging from 3.8 kA to 29.7 kA, but only 58 (24%) of these had |Ip| > 10 kA, and only one misclassified positive report had Ip > 20 kA. Radar analyses showed that most of the negative and positive CG strokes that were recorded on video were produced within or near the convective cores of storms. The radar imagery also showed that single-cell storms tended to produce one polarity of CG flashes at a time, and that such storms could switch rapidly from negative to positive CG flashes when the reflectivity was near maximum. Multiple-cell storms produced both negative and positive flashes over a broad region, but each polarity tended to cluster near regions of high-reflectivity.  相似文献   

15.
The intracloud (IC) discharge is closely related to the charge structure of thunderstorms. The location, charge moment and polarity of intracloud discharges have been analyzed by using the electric field changes from a 7-site network of slow antennas synchronized by GPS with 1 μs time resolution in the area of Zhongchuan in the Chinese Inland Plateau. Ten IC flashes, from a storm on August 20, 2004, have been fitted by using the non-linear least-square solution. The results show that five IC flashes occurred between the main negative charge region and the lower positive charge region and other five between the main negative charge region and the upper positive charge region during the mature stage of the thunderstorm. The centers of discharge were 3.2–5.6 km and 6.8–7.7 km above sea level. The neutralized moments were about 4.56–61.0 C km and 1.06–15.9 C km. It suggests that the charge structure related to the lightning discharge can be represented by a tripole but with a strong positive charge region in the lower part of the thunderstorm, with the lower positive charge region taking an active role in the discharge.  相似文献   

16.
Past studies based on the NOAA/AVHRR and GOES I-M imager instruments have documented the link between certain storm top features referred to as the “cold-U/V” shape in the 10–12 μm IR band imagery and plumes of increased 3.7/3.9 μm band reflectivity. Later, similar features in the 3.7/3.9 μm band have been documented in the AVHRR/3 1.6 μm band imagery.The present work focuses on storm top observations utilizing the MODIS data. The MODIS instrument (available onboard NASA's EOS Terra and Aqua satellites) provides image data with significantly better geometrical resolution (in some of its bands) and broader range of spectral bands as compared to that from AVHRR/3 observations. One of the goals of this study is to evaluate the contribution of this new instrument to observations of convective storm tops. Besides the cloud top features linked to storm top microphysics and morphology, the paper also addresses the possibility of detection of lower stratospheric water vapor above cold convective storm tops. This issue is explored utilizing MODIS as well as GOES and MSG imagery.In addition, the paper discusses an alternative interpretation of the “cold-U/V” patterns at the top of intense storms by a mechanism of “plume masking” as suggested by some of the observations.  相似文献   

17.
The potential resources on the ion-stimulated syntheses effects of aerosol particles of lower troposphere in test sites in the arctic, mountain, arid and forest areas as the function of irradiation time and gas-precursor concentration were experimentally and theoretically evaluated. The dust-free outdoor air was irradiated with an ionization current of 10− 6 A by α-rays from isotope 239Pu. The total output of radiolytic aerosols (RA) with a diameter of 3–1000 nm was found to be 0.05–0.1 molecules per 1 eV of absorbed radiation, while the physical upper limit is 0.25–0.4 molecules/eV. In an interval of exposition time from 6 to 800 s (adsorbed energy is 3 · 1012–1014 eV/cm3) the RA mass concentration at different sites was increased from 1–10 to 50–500 μg/m3. According to the liquid chromatography data the major RA material is the H2O/HNO3 solution with acid concentration  25%. The used physical model presents new aerosols as a product from small and intermediate ion association through formation of neutral clusters and describes adequately some of the peculiarities in field experiment data. Introducing SO2, NH3, and also hydrochloric, nitric and sulphuric acid vapours with concentration 0.1–1 mg/m3 in the irradiated air stimulated an increase of mass aerosol concentration by a factor of 8–30. The mean size also decreased by a factor of 3–5. These facts allowed us to expect that the chemical composition of radiolytic aerosols generated in outdoor air would noticeably differ after addition of the gas-precursors.  相似文献   

18.
We suggest a quantitative one-dimensional model treating the formation of charge layers near the 0 °C isotherm in stratiform regions of mesoscale convective systems. A number of factors principal for the field generation have been taken into account: both non-inductive and inductive melting charging, light ions, a complicated profile of the vertical air velocity near the 0 °С isotherm, the boundary conditions proper for the horizontally extended systems in the global electric circuit. Non-inductive collisional charging near the 0 °C isotherm was not considered. It was found that both non-inductive and inductive melting mechanisms can contribute; the inductive melting charging of ice aggregates was found more preferable, while the contribution of non-inductive mechanisms might be significant depending on particular conditions. The role of light ions in the formation of the positive charge layer near the 0 °C isotherm may be important. If the advection from the convective region ensures charge inflow to the upper charged layers, the melting charging mechanisms are able to explain an observable electric field structure in the whole stratiform region. It is important that the mutual position of the zero point on the vertical air velocity profile and the point of maximum melting-charge-transfer determines the fine structure of the electric field in the vicinity of the 0 °C isotherm.  相似文献   

19.
Normal alkanes and PAHs in atmospheric PM10 aerosols collected during 2008 winter and spring in Baoji, a mid-scale inland city of China, were determined on a molecular level. Concentrations of n-alkanes ranged from 232 to 3583 ng/m3 with an average of 1733 ng/m3 in winter and from 124 to 1160 ng/m3 with an average of 449 ng/m3 in spring, while PAHs in the PM10 samples were 594 ± 405 and 128 ± 82 ng/m3 in the two seasons. Molecular compositions showed that CPI (odd/even) values of n-alkanes were close to unity for all the samples especially in winter, and diagnostic ratios of PAHs (e.g., Phe/(Phe + Ant), CPAH/ΣPAHs and IcdP/(IcdP + BghiP)) were found similar to those in coal burning smoke with a strong linear relationship (R2 ≥ 0.85) between PAHs and fossil fuel derived n-alkanes, demonstrating that coal burning is the main source of n-alkanes and PAHs in the city, especially in winter due to house heating. Concentrations of the determined compounds in Baoji are much higher than those in Chinese mega-cities, suggesting that air pollution in small cities in the country is more serious and need more attention.  相似文献   

20.
This paper describes the leeside wind storm of 25–26 March 1998, the most intense wind storm of the last decade in Northwestern Greece. This wind storm produced wind gusts of  30 m s− 1 that resulted in tree uprooting, roof damaging, electric power network disruption and flooding in the lake-side areas of Ioannina city in Northwestern Greece. With the aim to identify the role of Mountain Mitsikeli near the city of Ioannina on the windstorm and to investigate the physical mechanisms responsible for such orographically induced weather events, numerical simulations with MM5 model have been performed. The model results showed that a resolution of 2-km resolution is necessary in order to reproduce the localized character of the wind storm. The analysis revealed that a synergistic combination of the cross-barrier northeasterly flow, the stable layer above the mountain top and the presence of a critical level, led to the intensification of the lee side winds during the studied wind event. Sensitivity experiments with modified topography, further supported the important role of mountain Mitsikeli that stands as an isolated obstacle, on the modification of the wind field during the observed windstorm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号