首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 185 毫秒
1.
The characteristics of cloud-to-ground (CG) lightning for ten hailstorms in Shandong Province of China were analyzed statistically. It is found that the hailstorms in this study present dominant positive CG flashes during periods of falling hail. One specific hailstorm on 16 June 2006 was studied in detail using the data from a CG lightning location network, Doppler radar and cloud images. Comparison between the brightness temperature of cloud-top and CG flash locations indicated that most flashes occurred in the region with temperatures lower than − 40 °C, while dense positive CG flashes occurred in the range between − 40 °C and − 50 °C. Negative CG flashes occurred mostly in the relative weak radar echo region, and positive CG flashes were distributed in the strong echo region especially with a large gradient of echo intensity. CG flashes tended to occur in the cloud region with reflectivity between 25 dBZ and 35 dBZ. Comparison between the wind field retrieved from Doppler radar and the location of CG flashes indicated that the flashes were located in the convergent region at lower to middle levels.  相似文献   

2.
Intracloud (IC) and cloud-to-ground (CG) lightning flashes produce transient changes in the electric field (E) above a thundercloud which drive transient currents in the global electric circuit (GEC). Using in-cloud and above-cloud E data from balloons, ground-based E data, and Lightning Mapping Array data, the above-cloud charge transfers due to lightning transients are estimated for five IC and five CG flashes from four thunderstorms that occurred above the mountains in New Mexico, USA, in 1999. For the five CG flashes (which transferred − 4 to − 13 C to the ground), the transient currents moved + 1 to + 5 C of charge upward from cloudtop toward the ionosphere, with an average transient charge transfer of about 35% of the charge transferred to ground. For the five IC flashes (which neutralized 6 to 21 C inside the cloud), the transient currents moved − 0.7 to − 3 C upward, with an average transient charge transfer of about 12% of the lightning charge. Estimates for three thunderstorms indicate that the transient currents made only a small GEC contribution compared to the quasi-stationary Wilson currents because of the offsetting effects of IC and CG flashes in these storms. However, storms with extreme characteristics, such as high flash rates or predominance of one flash type, may make a significant GEC contribution via lightning transients.  相似文献   

3.
The global electrical circuit, which maintains a potential of about 280 kV between the earth and the ionosphere, is thought to be driven mainly by thunderstorms and lightning. However, very few in situ measurements of electrical current above thunderstorms have been successfully obtained. In this paper, we present dc to very low frequency electric fields and atmospheric conductivity measured in the stratosphere (30–35 km altitude) above an active thunderstorm in southeastern Brazil. From these measurements, we estimate the mean quasi-static conduction current during the storm period to be 2.5 ± 1.25 A. Additionally, we examine the transient conduction currents following a large positive cloud-to-ground (+ CG) lightning flash and typical − CG flashes. We find that the majority of the total current is attributed to the quasi-static thundercloud charge, rather than lightning, which supports the classical Wilson model for the global electrical circuit.  相似文献   

4.
During the summers of 2003 to 2006 sprites were observed over thunderstorms in France by cameras on mountain tops in Southern France. The observations were part of a larger coordinated effort, the EuroSprite campaigns, with data collected simultaneously from other sources including the French radar network for precipitation structure, Meteosat with images of cloud top temperature and the Météorage network for detection of cloud-to-ground (CG) flash activity. In this paper two storms are analyzed, each producing 27 sprite events. Both storms were identified as Mesoscale Convective Systems (MCS) with a trailing stratiform configuration (ST) and reaching a maximum cloud area of ~ 120,000 km2. Most of the sprites were produced while the stratiform area was clearly developed and during periods of substantial increase of rainfall in regions with radar reflectivity between 30 and 40 dBZ. The sprite-producing periods followed a maximum in the CG lightning activity and were characterized by a low CG flash rate with a high proportion of + CG flashes, typically around 50%. All sprites were associated with + CGs except one which was observed after a − CG as detected by the Météorage network. This − CG was estimated to have − 800 C km charge moment change. The peak current of sprite-producing + CG (SP + CG) flashes was twice the average value of + CGs and close to 60 kA with little variation between the periods of sprite activity. The SP + CG flashes were further characterized by short time intervals before a subsequent CG flash (median value < 0.5 s) and with clusters of several CG flashes which suggest that SP + CG flashes often are part of multi-CG flash processes. One case of a lightning process associated with a sprite consisted of 7 CG flashes.  相似文献   

5.
Lightning and Doppler radar observations of a squall line system   总被引:2,自引:0,他引:2  
A typical squall line with damaging wind and hailstones occurred on 28 April 2006 in Shandong Province, middle eastern China, and caused great economic loss. The characteristics of cloud-to-ground lightning (CG) in the squall line were studied in detail by combining the data from the ground-based CG location network, two Doppler radars and the Lightning Imaging Sensor on the TRMM satellite. Results show that positive CG flashes accounted for 54.7% of the total CG flashes. During the initial developing stage, the CG flash rate was lower than 0.5fl min− 1 and most of the CG flashes were positive. It increased significantly, up to 4.5fl min− 1, along with the rapid development of the squall line, and the percentage of positive CG was more than 75% during this period. The CG flash rate began to decrease but the percentage of negative CG flash increased gradually and exceeded that of positive CG during the mature and dissipating stages. Positive CG flashes tended to occur on the right flank and negative ones on the left flank. Strong wind at the surface occurred in or near the regions with dense positive CG flashes. Almost all positive CG flashes occurred near the strong radar echo regions, in the front parts of the squall line. However, the negative CG flashes almost exclusively occurred in the regions with weak and uniform radar echoes. The total flash rate in the storm was very high, up to 136fl min− 1, and its ratio of intracloud flashes (IC) to CG flashes was 35:1. Dense positive CG flashes corresponded to updraft regions, they did not occur in the core of the updraft, but just behind and close to the main updraft instead. The rear inflow jet, between 3 and 6 km, played an important role in the formation of the bow echo and very strong wind at surface. The CG distribution features in the squall line were obviously different from that of an ordinary MCS. The charge structure could be roughly described as an inverted charge structure.  相似文献   

6.
GPS-synchronized measurements of electric (E) field changes induced by lightning flashes were recorded at six stations in the northeastern verge of the Tibetan Plateau. The height and magnitude of charge neutralized by 65 return strokes, including 16 negative cloud-to-ground (CG) flashes and 2 positive CG flashes, have been fitted with the nonlinear least-square method based on the E field changes of CG flashes observed in a typical thunderstorm with larger-than-usual lower positive charge center (LPCC). Results show that the height of the charge region neutralized by negative CG flashes ranges from 3 km to 5 km above the ground, corresponding to an ambient temperature between − 2 °C and − 15 °C. For the two positive CG flashes, the neutralized charge regions are located at a height of about 5.5 km and the ambient temperature is about − 18 °C, indicating the existence of upper positive charge in the thunderstorm.  相似文献   

7.
By using a high-speed video camera system (1000 frames s− 1) in correlation with fast and slow antenna systems, the negative cloud-to-ground (CG) flashes that struck the ground with more than one termination have been analyzed. This kind of stroke, named as multiple-ground terminations stroke (MGTS), was produced by different branches of the same stepped leader during quite a short time. Based on optical images, the 2D progression speed of leader branches was estimated to be in the range (0.9–2.0) × 105 m s− 1. The distance between adjacent striking points of MGTS was from 0.2 km to 1.9 km. The percentage of flashes with multiple-ground terminations occupied about 15% (9 out of 59) of the total negative CG flashes, with a range of 11%–20% in different areas in China. The time intervals between the two adjacent peaks ranged from 4 μs to 486 μs based on the E-field change caused by the MGTS. The flashes which had multiple striking points on the ground during quite a short time may be a common phenomenon in the lightning discharge process. It might produce more serious damage to facilities on the ground and should not be neglected in the design of lightning protection.  相似文献   

8.
A significant enhancement in the number of negative cloud-to-ground (CG) lightning and a decrease in the percentage of positive CG flashes are observed over the city of São Paulo, similar to observations in other large urban areas. Strong evidence indicates that this anomalous behavior results from several mechanisms related to the urban effect. In this paper, we investigated the importance of the air pollution using CG lightning data provided by the Brazilian lightning detection network (BrasilDAT) for a 6-year period (1999–2004). Due to the large variations in the CG lightning activity in response to different meteorological processes, it is not an easy task to infer the contribution of air pollution to the enhancement in the lightning activity. In order to overcome such difficulty, two approaches were considered: (1) the weekly variation of the number of days with lightning in comparison to the mean concentration of particulate matter (PM10), as well as other thermodynamical parameters; (2) the variation of the number of CG flashes and the maximum storm flash rate per individual thunderstorm for different levels of pollution. The results of both analyses suggest that: first, the enhancement in the CG lightning activity during the week days over São Paulo metropolitan region is related to the PM10 concentration (pollution); second, the PM10 concentration tends to increase the lifetime of the storms and, in consequence, the number of flashes per storm, and not the flash rate of the thunderstorm; and third, the effect of the pollution in the enhancement of the CG lightning activity is probably less significant compared to the effect of the urban heat island.  相似文献   

9.
Using high-speed cameras, we have recorded the leaders contained in four natural negative cloud-to-ground (CG) lightning flashes in the summers of 2006 and 2007 at Conghua, Guangdong, China. It was found that the downward negative leaders preceding the first return stroke could propagate at quite different speeds. In one flash, the average speed of the downward negative stepped leader with no branches is about 2.2 × 106 m s− 1, while that of the other 3 flashes are all of the order of 105 m s− 1 with multilevel branches. The luminosity of the leaders shows an increasing tendency in propagating downward to the ground. For the leaders preceding the subsequent strokes, although all of them exhibit high speeds as reported previously. One subsequent leader exhibits an increasing speed from 5.2 × 105 m s− 1 to 1.7 × 106 m s− 1 during its propagation from about 1.26 to 0.36 km above the ground, and its luminosity also increased. The speed and luminosity of a leader between subsequent strokes of a natural lightning appear to decrease as it developed downward. Its speed ranges from 1.1 × 106 to 1.1 × 105 m s− 1, with a height between 1.15 and 0.81 km above the ground.  相似文献   

10.
The intracloud (IC) discharge is closely related to the charge structure of thunderstorms. The location, charge moment and polarity of intracloud discharges have been analyzed by using the electric field changes from a 7-site network of slow antennas synchronized by GPS with 1 μs time resolution in the area of Zhongchuan in the Chinese Inland Plateau. Ten IC flashes, from a storm on August 20, 2004, have been fitted by using the non-linear least-square solution. The results show that five IC flashes occurred between the main negative charge region and the lower positive charge region and other five between the main negative charge region and the upper positive charge region during the mature stage of the thunderstorm. The centers of discharge were 3.2–5.6 km and 6.8–7.7 km above sea level. The neutralized moments were about 4.56–61.0 C km and 1.06–15.9 C km. It suggests that the charge structure related to the lightning discharge can be represented by a tripole but with a strong positive charge region in the lower part of the thunderstorm, with the lower positive charge region taking an active role in the discharge.  相似文献   

11.
In July 2005, a field campaign was conducted in the Central Great Plains to obtain 60-field/s video imagery of lightning in correlation with reports from the U.S. National Lightning Detection Network (NLDN) and broadband electric field waveforms from the Los Alamos Sferic Array (LASA). A total of 342 GPS time-stamped cloud-to-ground (CG) flashes were recorded in 17 different sessions, and 311 (91%) of these were correlated with reports from the NLDN. Only 6 of the 17 recording sessions were dominated by flashes that lowered negative charge to ground, and 11 were dominated by positive CG flashes. A total of 103 flashes recorded on video were correlated with at least one NLDN report of negative CG strokes, 204 video flashes were correlated with one or two positive stroke reports, and 4 had bipolar reports. In this paper, we will give distributions of the estimated peak current, Ip, as reported by the NLDN, of negative and positive first strokes that were recorded on video, the multiplicity of strokes that were recorded on video, and the number of ground contacts per flash that were resolved on video. 41 (40%) of the negative flashes produced just a single-stroke on video, and 62 (60%) showed two or more strokes. The observed multiplicity of negative flashes averaged 2.83, which becomes about 3.14 after correcting for the finite time-resolution of the video camera. 195 (96%) of the positive flashes produced just a single-stroke on video, and 9 (4%) showed two strokes; therefore, the observed multiplicity of positive flashes averaged 1.04. Five out of 9 (56%) of the positive subsequent strokes re-illuminated a previous channel, and 4 out of 9 (44%) created a new ground contact. Simultaneous video, LASA, and NLDN measurements also allowed us to examine the classification of NLDN reports during 3 single-cell storms (one negative and two positive). Based on the LASA waveforms, a total of 204 out of 376 (54%) NLDN reports of CG strokes were determined to be for cloud pulses. The misclassified negative reports had |Ip| values ranging from 3.8 kA to 29.7 kA, but only 58 (24%) of these had |Ip| > 10 kA, and only one misclassified positive report had Ip > 20 kA. Radar analyses showed that most of the negative and positive CG strokes that were recorded on video were produced within or near the convective cores of storms. The radar imagery also showed that single-cell storms tended to produce one polarity of CG flashes at a time, and that such storms could switch rapidly from negative to positive CG flashes when the reflectivity was near maximum. Multiple-cell storms produced both negative and positive flashes over a broad region, but each polarity tended to cluster near regions of high-reflectivity.  相似文献   

12.
从一般雷暴、灾害性雷暴和台风的闪电活动特征以及雷暴闪电尺度特征四个方面对相关研究进行梳理。一般雷暴通常具有正常极性电荷结构,云/地闪比例在3左右(中纬度地区),地闪中正地闪占比为10%左右,负地闪位置往往更集中于对流区。灾害性雷暴倾向具有活跃的云闪,低比例的地闪,易出现反极性电荷结构,正地闪比例偏高。闪电活动与灾害性天气现象之间存在关联性,部分雹暴过程具有两次闪电活跃阶段。台风中大部分闪电发生在外雨带,眼壁/外雨带闪电爆发很可能预示气旋强度的增强以及路径的改变。由闪电持续时间、通道空间扩展所表征的闪电尺度与雷暴对流强度相关。弱对流雷暴或雷暴的弱对流区域可能由水平扩展、垂直分层的电荷分布形态主导,闪电频次低,闪电空间尺度大;强对流雷暴或雷暴的强对流区域可能由交错分布的小电荷区主导,闪电频次高,闪电尺度小。   相似文献   

13.
孙哲  魏鸣 《大气科学学报》2016,39(2):260-269
利用NCEP再分析资料、探空资料、闪电定位资料和南京、常州多普勒雷达资料,通过对比分析南京2012年2月22日春季雷暴和2011年8月10日夏季雷暴两次过程,研究不同季节影响雷暴发生的大气结构以及强弱雷暴地闪特征的差异。结果表明:风矢位温(V-3θ)图揭示的大气动力热力水汽特征能够为雷暴的潜势预报提供先兆信息。两者相较而言,春季雷暴的动力抬升作用明显;夏季雷暴主要由热对流引起,对流层上层的动力抽吸作用不明显。春季弱雷暴正地闪在总地闪中所占比例较高。无论春季弱雷暴还是夏季强雷暴,地闪落点与辐合区对应关系明显,且地闪的落点也与雷达反射率因子有较好的对应关系:地闪主要分布在强回波区(大于40 d Bz)及其外围区域。但在较强雷暴云的发展阶段,地闪多发生在风暴体伸展方向的一侧,具有引导雷达回波移动的作用,夏季强雷暴地闪簇集在垂直风切变区域。  相似文献   

14.
雷暴天气过程中降水结构与闪电活动特征个例研究   总被引:1,自引:0,他引:1  
为深入分析四川雷暴天气过程中降水和闪电活动特征,运用统计与对比方法,对四川东南部一次雷暴过程中闪电活动及降水结构之间的特征进行研究。结果表明,强降水易发生在低层辐合,高层辐散的流场中,局部地区最大降水强度发生在2~5km高度。降水开始1h后,地闪频数达到最高,地闪主要以负地闪为主,正地闪不活跃。对闪电活动与亮温分布关系知,闪电活动主要发生在低于220K降水云内,闪电活动发生的区域与降水落区一致。对总闪与地闪的分布知,负地闪主要分布在总闪的外围。通过对四川雷暴过程的研究,对雷暴预报有一定的指导意义。  相似文献   

15.
北京夏季强雷暴降水回波结构与闪电特征个例分析   总被引:3,自引:1,他引:2  
利用北京市气象局短时临近交互预报系统(VIPS)资料,对2008年奥运会期间两次强降水天气过程雷达回波结构及闪电时空特征进行了细致分析。结果表明,局地性强雷暴降雨天气中,降雨率峰值与闪电活动峰值关系有超前也有略滞后的情况;关于云闪和地闪出现时间,云闪一般要超前地闪5~15min;强降水回波单体中,总闪电次数的70%以上出现在大于40dBZ的强回波区,当最大回波强度大于60dBZ时,云闪出现在强回波区的概率接近90%,说明回波强度越强,云闪出现在强回波区的概率越大;对云闪与雷达回波垂直结构分析发现,强降水单体中云闪发生的高度主要在6km以上,且云闪发生频数峰值出现在8~11km高度。  相似文献   

16.
华北一次强对流天气系统的地闪时空演变特征分析   总被引:8,自引:3,他引:5  
利用地面雷电探测网,多普勒天气雷达和常规天气资料,分析了2005年8月1日发生在山东北部的一次具有前部对流线,后部大范围层状云降水(LLTS)的典型中尺度对流系统(MCS)的闪电活动演变特征。结果表明:整个过程中负地闪占主导地位,最高频数达到260次/5min;与负地闪比较,正地闪呈现不活跃状态。负地闪主要落在>40 dBz的强回波区内部及其边缘区域,而正地闪则分布在前部云砧和后部层状云降水区内。对地闪位置与回波强度的进一步对比分析发现,45~55 dBz的回波是最有利于地闪发生的区域,回波强度低于这一区域,随着回波强度的增大,地闪活动呈递增趋势,地闪频数在50~55 dBz的回波区域内达到峰值,>55 dBz的回波区域内地闪频数明显降低。  相似文献   

17.
The initial discharge stages of two flashes during the Shandong Artificially Triggering Lightning Experiment (SHATLE) are analyzed based on the synchronous data of the current and close electromagnetic field. For a lightning flash, named 0503, the wire was connected, not electrically, but via a 5 m length of nylon, with the lightning rod; while for another, named 0602, the wire was connected with the rod directly. Results show that the discharge processes of the initial stage (IS) in flash 0503 are quite different from that of the usual classical-triggered flash 0602 and altitude-triggered flashes. A large pulse with a current of about 720 A resulted from the breakdown of the 5 m air gap during flash 0503, and the corresponding electric field at 60 m from the lightning rod was 0.38 kV/m. The upward positive leaders (UPLs) propagated continuously from the tip of the rocket after this breakdown. The geometric mean (GM) of the UPL peak current was 23.0 A. Vaporization of the wire occurred during the initial continuous current (ICC) stage and the largest current pulse was about 400 A. Compared with triggered flash 0503, the discharge processes of IS in flash 0602 were simple, only two large pulses similar to each other occurred before dart leader/return stroke sequences. The peak current of the first pulse was 2.1 kA and its corresponding electric field and magnetic field at a distance of 60 m from the lightning rod were 0.98 kV/m and 7.03 μT, respectively. During the second pulse, the wire disintegrated. The current decreased to the background level at the moment of the wire disintegration. The current of the second pulse in triggered flash 0602 was 2.8 kA, and the corresponding electric field and magnetic field at 60 m from the lightning rod were 1.22 kV/m and 9.01 μT, respectively.  相似文献   

18.
This paper is focused on the study of rainfall yield characteristics of electrical storms observed over the Northern Iberian Peninsula during 1992–1996. To this aim Principal Components Analysis (PCA) and Self-Organizing Maps (SOM) method have been used. The SOM method is a group of artificial neural networks based on the topological properties of the human brain. Results clearly suggest that there exist three different meteorological patterns that are linked to the characteristics of electrical events found in the study area. In winter, most of the electrical events are formed under oceanic advection (NW air fluxes). On these cases, mean rainfall yield estimates reach values of 700 104 m3 per cloud to ground lightning flash (CG flash). During summer most frequent electrical storms are associated to local instability shooting by surface heating with advection of humidity coming from the Iberian Peninsula. Under these meteorological situations, rain is scarcer if compared with oceanic events but lightning CG counts reach the maximum values found in the area (about 10 CG counts per 20 × 20 km2 and day) giving this way the smallest rainfall yield with a mean value of 15 104 m3 per CG flash. Iberian air fluxes associated with cold air in upper parts of the atmosphere represent the third meteorological pattern found. This pattern is most common in spring and autumn but is not unusual in the rest of the seasons. In those cases mean rainfall yield in the area is about 150 104 m3 per CG flash. In all electrical episodes K instability index is greater than 15 °C but in the most lightning producing events, this index reaches in the area values greater than 24 °C. PCA results pointed out that there exists a relationship between rain and CG counts expressed by the first principal component computed from standardized data. However, we must notice that no event is solely linked to this axis, since a seasonal influence which decreases lightning production when rain increases is always present. Results found are of great interest for short term forecasting of flashfloods in mountainous areas like the Spanish Basque Country region.  相似文献   

19.
利用地面地闪定位资料、多普勒天气雷达和常规气象资料, 分析了一次具有前部对流线和后部大范围层状云降水(LLTS)的典型中尺度对流系统(MCS)的闪电活动演变特征。整个MCS生命史中负地闪占主导地位, 正地闪则表现不活跃。观测得到MCS消散阶段云闪与地闪的比例为2∶1, 地闪主要分布在地面相对位温和对流不稳定能量均达到高值的区域; 负地闪主要密集地分布在大于40 dBZ的回波范围内; 正地闪则稀疏地分布在30~40 dBZ的回波范围内。在低于-40℃的温度区域内地闪分布较多, 而密集的地闪分布在温度梯度大的区域内。结合单多普勒雷达的水平风场反演, 发现地闪集中出现在气流表现为气旋性切变或水平风呈现切变的区域。该区域与MCS的强回波区相对应, 并且地闪易发生在上升气流达到最大并开始出现下沉气流的阶段。  相似文献   

20.
The analyses of spatial and temporal characteristics of positive cloud-to-ground(CG) lightning for four mesoscale convective systems and two severe local convective systems in 1989 and 1990 show that positive CG flash rate usually has two peak values.The major peak occurs during the developing stage of the storm and most of the positive CG flashes originate at the lower part of the storm.The minor occurs during the dissipative stage of the storm and most of the positive CG flashes originate at the upper part of the storm,especially in the region of the wind divergence in the storm anvil.The positive CG flash rate is almost an order of magnitude larger in the developing stage than in the dissipative stage.The appearing time of the peak of negative CG flash rate is in accordance with that of the valley of positive CG flash rate.The higher the intensity of the radar echo,the higher the positive CG flash rate.Most of the positive CG flashes occur when the weak echo area is larger,and mostly originate in the region where the radar echo intensity is about 10dBz and in the back region of the moving storms.The spatial distribution of the positive CG flashes is much more dispersive than that of the negative.The mesoscale analysis reveals a bipolar lightning pattern.The mean bipole-length reaches its minimum during the mature stage of the storm and reaches the maximum during the developing stage of the storm.The vertical distribution of the charge density is calculated by a one-dimensional charging model.Then,we discuss the producing condition of the positive CG lightning and forming cause of charge structure mentioned above.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号