首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The isolation systems are usually made of rubber bearings that are sometimes coupled in hybrid combination with frictional devices; this is the case of an in-site experimental campaign, performed on a base isolated apartment building in Rapolla (south of Italy). Several dropout tests at initial displacements up to 17cm allowed to obtain in-site information on the true dynamic response of the isolation system (building and isolators). The tests carried out allow a comparison between the free vibration responses of a building, isolated by using a 28 HDRB isolation system only, or an HDRB-Friction Sliders Hybrid one. The paper highlights the main differences of the response in the superstructure (the structure over the isolation system) obtained by using only HDRB isolation system, or the Hybrid one (HDRB and Friction Sliders in parallel system). Analysis and comparisons of experimental data, show the influence of nonlinearities on structural higher modes amplification, especially observed by using the higher nonlinear Hybrid isolation system. Tests results confirm that, in the case of a regular superstructure, like the Rapolla building, the isolation system nonlinearities influence the structural response.  相似文献   

2.
In this paper, the effectiveness of the base isolation on steel storage tanks has been investigated through numerical models and then checked by shaking table tests on a reduced scale (1:14) model of a real steel tank, typically used in petrochemical plants. In the experimental campaign the floating roof has also been taken into account. The tests have been performed on the physical model both in fixed and isolated base configurations; in particular two alternative base isolation systems have been used: high‐damping rubber bearings devices and sliding isolators with elasto‐plastic dampers. Finally, a comparison between experimental and numerical results has also been performed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
村镇隔震砌体结构振动台试验方案设计研究   总被引:1,自引:1,他引:0  
为使铅芯橡胶支座隔震技术应用于村镇砌体结构,将隔震层设置于地坪以上,本文给出了隔震构造的具体做法。选取典型村镇2层未设构造柱的砖砌体结构房屋为试验原型,按1:2缩尺,设计有隔震层和无隔震层的振动台对比试验。首先采用反应谱分析方法,对隔震和非隔震结构分别选取三条地震波,然后通过数值分析,研究隔震和非隔震结构在输入不同地震波时的地震反应规律,根据数值模拟的分析结果设计结构振动台试验中的传感器布置和加载方案。本文设计的砌体隔震振动台试验方案已试验成功,可为振动台试验设计和研究提供参考。  相似文献   

4.
Base isolation is a well known technology that has been proven to reduce structural response to horizontal ground accelerations. However, vertical response still remains a topic of concern for base‐isolated buildings, perhaps more so than in fixed‐base buildings as isolation is often used when high performance is required. To investigate the effects of vertical response on building contents and nonstructural components, a series of full‐scale shaking table tests were conducted at the E‐Defense facility in Japan. A four‐story base‐isolated reinforced concrete building was outfitted as a medical facility with a wide variety of contents, and the behavior of the contents was observed. The rubber base isolation system was found to significantly amplify vertical accelerations in some cases. However, the damage caused by the vertical ground motions was not detrimental when peak vertical floor accelerations remained below 2 g with three exceptions: (1) small items placed on shelves slid or toppled; (2) objects jumped when placed on nonrigid furniture, which tended to increase the response; and (3) equipment with vertical eccentricities rocked and jumped. In these tests, all equipment and nonstructural components remained functional after shaking. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
An experimental test program on a full‐scale model representing a sub‐assemblage of the cloister facade of the Sao Vicente de Fora monastery, retrofitted through base isolation, has been recently carried out at the European Laboratory for Structural Assessment of the Joint Research Centre of the European Commission. In this paper an overview of the laboratory model and the experimental results is provided. In particular, firstly the test model is described, including the geometry and mechanical properties of the masonry specimen and the design of the isolation devices; then the testing method and the sub‐structuring of the isolation system are described and the seismic inputs adopted for the pseudo‐dynamic tests are defined. Finally, the experimental results are discussed and compared to the analogous results obtained on the ‘as is’, fixed‐base sub‐assemblage model. The implications of the test outcomes are emphasized and developments of this research line are presented. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

6.
During past strong earthquakes, highway bridges have sustained severe damage or even collapse due to excessive displacements and/or very large lateral forces. For commonly used isolation bearings with a pure friction sliding surface, seismic forces may be reduced but displacements are often unconstrained. In this paper, an alternative seismic bearing system, called the cable-sliding friction bearing system, is developed by integrating seismic isolation devices with displacement restrainers consisting of cables attached to the upper and lower plates of the bearing. Restoring forces are provided to limit the displacements of the sliding component. Design parameters including the length and stiffness of the cables, friction coefficient, strength of the shear bolt in a fixed-type bearing, and movements under earthquake excitations are discussed. Laboratory testing of a prototype bearing subjected to vertical loads and quasi-static cyclic lateral loads, and corresponding numerical finite element simulation analysis, were carried out. It is shown that the numerical simulation shows good agreement with the experimental force-displacement hysteretic response, indicating the viability of the new bearing system. In addition, practical application of this bearing system to a multi-span bridge in China and its design advantages are discussed.  相似文献   

7.
The rolling motion of mutually orthogonal rollers respectively sandwiched between two bearing plates in which one or both have V‐shaped sloping surfaces makes the sloped rolling‐type isolation device have an excellent in‐plane seismic isolation performance. In this study, the sloped rolling type isolation device in which a single roller moves between two V‐shaped sloping surfaces along each principle horizontal direction is refined by incorporating multi‐roller, built‐in damping, and pounding prevention mechanisms. The associated dynamic behavior is further clarified, and a simplified twin‐flag hysteretic model, which can be easily applied in most commercial computational tools is then proposed. Seismic simulation tests on the refined isolation devices (i.e. the sloped multi‐roller isolation devices) with different design parameters such as sloping angles of bearing plates and built‐in damping capabilities, together with a raised floor system by employing the sloped multi‐roller isolation devices, were conducted. Not only is the efficiency of the sloped multi‐roller isolation devices in seismically protecting the important objects, but also the practicability and accuracy of the proposed simplified numerical model in predicting the seismic responses of the sloped multi‐roller isolation devices is experimentally verified. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
The seismic response of light secondary systems in a building is dependent on the response of the primary structural system to the seismic ground motion with the result that very high accelerations can be induced in such secondary systems. This response can be reduced through the use of aseismic base isolation which is a design strategy whereby the entire building can be decoupled from the damaging horizontal components of seismic ground motion by the use of some form of isolation system. The paper presents a theoretical analysis of the response of light equipment in isolated structures and a parallel experimental programme both of which show that the use of base isolation can not only attenuate the response of the primary structural system but also reduce the response of secondary systems. Thus, the design of equipment and piping in a base-isolated building is very much simpler than that for a conventionally founded structure: inelastic response and equipment-structure interaction need not be considered and multiple support response analysis is rendered unnecessary. Although an isolation system with linear elastic bearings can reduce the acceleration of the structure, it may be accompanied by large relative displacements between the structure and the ground. A system using lead-rubber hysteretic bearings, having a force-displacement relation which is approximately a bilinear loop, can reduce these displacements. A parallel experimental programme was carried out to investigate the response of light equipment in structures isolated using lead-rubber bearings. The experimental results show that these bearings can dissipate energy and limit the displacement and acceleration of the structure but are less effective in reducing the accelerations in the internal equipment. The results of both the analysis and the tests show that base isolation is a very effective method for the seismic protection of light equipment items in buildings.  相似文献   

9.
Experimental Investigations on Laminated Rubber Bearings   总被引:1,自引:0,他引:1  
Increasing application of base isolation as a seismic protection method has subsequently increased its analytical and experimental studies. Being the most critical part of the base isolated buildings, accurate evaluation of structural properties and precise modeling of isolation devices is of utmost importance in predicting the response of the buildings during the earthquakes. This technical note is concerned with experimental study on laminated rubber bearings. Free vibration and harmonic base excitation tests are performed on a three-storey building model to evaluate the properties of the structure, efficiency of the system, and effect of base excitations. It is found that these experimental methods can effectively be used for this purpose.  相似文献   

10.
This paper investigates and compares the seismic performance of two types of innovative repairable fuse devices for earthquake resistant composite steel frames through experimental tests and numerical analyses. The fuses are energy dissipating devices consisting of steel plates that can be welded or bolted to the beam web and bottom flange. The numerical analyses performed in this study are based on the results of experimental tests carried out on beam-to-column sub-assemblages equipped with both the types of fuse devices. The main differences in terms of hysteretic behavior and failure modes of the fuses are identified through the experimental campaign. Detailed three-dimensional finite element models of the beam-to-column sub-assemblages are then created to provide a deeper insight into both the response and the effectiveness of the two investigated devices. On the basis of the results of both the experimental tests and numerical analyses, simplified models of different types of fuses are developed in order to study the effects of bolted and welded devices on the seismic response of composite steel frames. The results are then extended to the case of three-dimensional building structures with different number of storeys. The experimental and numerical investigations prove the effectiveness of the fuses and highlight the main differences between the two possible solutions.  相似文献   

11.
The seismic response of a critical rotating machine either rigidly attached to a floor or independently isolated housed within an initially aseismically designed or uncontrolled structure are investigated. A particular isolation system, the Resilient‐Friction Base Isolator (RFBI), is employed. Finite element formulations of a rotor‐disk‐bearing model on a rigid base are developed. The equations of motion for the combined rotating machine–structure–RFBI systems are presented. Parametric studies are performed to investigate the effects of variations in system physical properties including friction coefficient, mass ratio, shaft flexibility, bearing rigidity, bearing damping and speed of rotation on the response of rotating machines for the combined rotating machine–structure–isolator systems. Comparative studies in the peak response of the rotating machine supported on various isolation systems and the corresponding fixed base system are carried out. The study indicates that the Resilient‐Friction Base Isolator can significantly reduce the seismic response of rotating components to potentially damaging ground excitations. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

12.
针对目前隔震体系尚不能减小竖向地震反应的缺陷,提出并研制了采用碟形弹簧的竖向半主动隔震装置。竖向半主动隔震装置是由碟形弹簧和外套油缸组成的,且由电磁阀控制油缸内油体与外接蓄油箱内油体间的油路,可实现竖向半主动隔震控制,提出了竖向隔震控制的半主动策略,结合水平隔震支座可实现三维隔震。通过振动台地震模拟实验,验证了三维隔震体系的效能,该研究对高烈度地区隔震技术的改善具有应用参考价值。  相似文献   

13.
This paper presents an experimental and numerical study to investigate the hysteretic performance of a new type of isolator consisting of shape memory alloy springs and friction bearing called an SMA spring-friction bearing (SFB). The SFB is a sliding-type isolator with SMA devices used for the seismic protection of engineering structures. The principle of operation of the isolation bearing is introduced. In order to explore the possibility of applying SMA elements in passive seismic control devices, large diameter superelastic tension/compression NiTi SMA helical springs used in the SFB isolator were developed. Mechanical experiments of the SMA helical spring were carried out to understand its superelastic characteristics. After that, a series of quasi-static tests on a single SFB isolator prototype were conducted to measure its force-displacement relationships for different loading conditions and study the corresponding variation law of its mechanical performance. The experimental results demonstrate that the SFB exhibits full hysteretic curves, excellent energy dissipation capacity, and moderate recentering ability. Finally, a theoretical model capable of emulating the hysteretic behavior of the SMA-based isolator was then established and implemented in MATLAB software. The comparison of the numerical results with the experimental results shows the efficacy of the proposed model for simulating the response of the SFB.  相似文献   

14.
While isolation can provide significantly enhanced performance compared to fixed‐base counter parts in design level or even maximum considered level earthquakes, there is still uncertainty over the performance of isolation systems in extreme events. Researchers have looked at component level stability of rubber bearings and on the effect of moat impact on behavior of structures isolated on general bilinear isolators. However, testing of triple friction pendulum (TFP) sliding bearings has not been done dynamically or incorporated into a building system. Here, one‐third scale laboratory tests were conducted to on a 2‐story 2‐bay TFP‐isolated structure. Input motions were increasingly scaled until failure occurred at the isolation level. As the superstructure was designed with a yield force equivalent to the force of the bearing just at their ultimate displacement capacity, there was minimal yielding. A numerical model is presented to simulate the isolated building up to and including bearing failure. Forces transferred to the superstructure in extreme motions are examined using both experimental and numerical data. Additionally, the effect of the hardening stage of the TFP bearing is evaluated using the numerical model, finding slight benefits.  相似文献   

15.
A new base isolation method is proposed for the protection of structures. Because of the efficiency of the isolation devices, the isolated structure may be made to remain elastic throughout major earthquakes. This device consists of two sets of mutually orthogonal free rolling rods under the basement of the structure. Since the coefficient of rolling friction of the rods is very small in practice, the structure can be isolated excellently from the support excitation. In this paper, the analytical method and the response of the isolated system for different parameters, such as the periods of the structure, the coefficient of rolling friction and the masses of rolling rods, are presented. The results indicate that the proposed method is excellent in isolating the structure from support excitations, as expected.  相似文献   

16.
An experimental investigation on a base isolation system incorporating stainless steel–Teflon bearings as sliders, and pressurized fluid viscous spring dampers, is presented in this paper. In the system examined, dampers are connected to the base floor of an isolated building to provide the desired passive control of response in the superstructure, as well as to guarantee that it re‐centres completely after the termination of a seismic action. Two types of experiments were conducted: sinusoidal and random cyclic tests, and a pseudodynamic test in ‘substructured’ configuration. The cyclic tests were aimed at characterizing what follows: the hysteretic and strain‐rate‐dependent response of the considered highly non‐linear spring dampers; the normal pressure‐ and strain‐rate‐dependent frictional behaviour of steel–Teflon bearings, manufactured in compliance with the latest standards for this class of sliders; and the combined response of their assembly. The pseudodynamic test simulated the installation of the protection system at the base of a 2:3‐scale three‐storey steel frame structure, already tested in unprotected conditions by an earlier experimental campaign. Among other findings, the results of the performed tests, as well as of relevant mechanical interpretation and numerical simulation analyses, confirmed the linear additive combination of the dissipative actions of spring dampers and sliders in this mixed installation, and the high protective performance of the considered base isolation/supplemental damping system in a realistic earthquake simulation. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

17.
Bridge seismic isolation strategy is based on the reduction of shear forces transmitted from the superstructure to the piers by two means: shifting natural period and earthquake input energy reduction by dissipation concentrated in protection devices. In this paper, a stochastic analysis of a simple isolated bridge model for different bridge and device parameters is conducted to assess the efficiency of this seismic protection strategy. To achieve this aim, a simple nonlinear softening constitutive law is adopted to model a wide range of isolation devices, characterized by only three essential mechanical parameters. As a consequence of the random nature of seismic motion, a probabilistic analysis is carried out and the time modulated Kanai-Tajimi stochastic process is adopted to represent the seismic action. The response covariance in the state space is obtained by solving the Lyapunov equation for a stochastic linearized system. After a sensitivity analysis, the failure probability referred to extreme displacement and the mean value of dissipated energy are assessed by using the introduced stochastic indices of seismic bridge protection efficiency. A parametric analysis for protective devices with different mechanical parameters is developed for a proper selection of parameters of isolation devices under different situations.  相似文献   

18.
A variant type of tuned mass damper (TMD) termed as ‘non‐traditional TMD (NTTMD)’ is recently proposed. Mainly focusing on the employment of TMD for seismic response control, especially for base‐isolated or high‐rise structures, this paper aims to derive design formulae of NTTMDs based on two methodologies with different targets. One is the fixed points theory with the performance index set as the maximum magnitude of the frequency response function of the relative displacement of the primary structure with respect to the ground acceleration, and the other is the stability maximization criterion (SMC) to make the free vibration of the primary structure decay in the minimum duration. Such optimally designed NTTMDs are compared with traditional TMDs by conducting both numerical simulations and experiments. The optimum‐designed NTTMDs are demonstrated to be more effective than the optimum‐designed traditional TMDs, with smaller stroke length required. In particular, the effectiveness of the TMDs combined with a base‐isolated structure is investigated by small‐scale model experimental tests subjected to a time scaled long period impulsive excitation, and it is demonstrated that the SMC‐based NTTMD can suppress structural free vibration responses in the minimum duration and requires much smaller accommodation space. Additionally, a small‐scale shaking table experiment on a high‐rise bending model attached with a SMC‐based NTTMD is conducted. This study indicates that NTTMD has a high potential to apply to seismic response control or retrofit of structures such as base‐isolated or central column‐integrated high‐rise structures even if only a limited space is available for accommodating TMDs. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
This work investigates the efficiency of mixed base isolation, combining passive isolation bearings with semi-active (SAC) devices, to reduce the floor spectral acceleration in the vicinity of the non-isolated modes’ frequencies. Both analytical and experimental studies have been carried out. Analytical results of the behaviour of a multiple degree of freedom base isolated structure demonstrate the efficacy of the method. Though the considered controller is based on a reduced order model with only two degrees of freedom (2 DOF) without spillover compensation, the results show that, for the type of structures studied here, spillover effects are not considerable. An experimental study of a 2 DOF model of a base isolated structure equipped with a semi-active magneto-rheological (MR) damper has been carried out. Due to limitations of the experimental set-up, it has not been possible to obtain direct experimental evidence of the efficacy of SAC control to improve floor spectra. Nevertheless, based on the good agreement between analytical and experimental results which validate the considered MR model and control algorithm, numerical analyses of more relevant configurations illustrated the benefit of the utilization of such devices.  相似文献   

20.
The experimental work and first results of a recently completed experimental research programme investigating the response of reinforced concrete (RC) walls under earthquake (EQ) loading are discussed in this paper. A brief literature review is given as a prelude to the outline of research objectives. The tests are presented in two groups according to the scale of models. For the 1:5 scale tests, a modified similitude relation for small scale reinforced concrete dynamic modelling is developed. Based on the chosen model parameters, the design of the isolated RC walls is given. The test-rig set-up and the EQ input signals suitable for testing the model on the Imperial College shake-table are also discussed. Preliminary observations regarding stiffness, strength and failure modes of the RC wall models are given. Experimental results from the shake-table are compared to tests, at the same scale, under static cyclic conditions. For the scale 1:2–5 cyclic tests a different test-rig assembly is designed. The test results are given in three pairs of flexurally similar walls followed with general observations and discussion. Finally, conclusions are drawn regarding experimental procedures and behaviour patterns of the tested models.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏