首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
大连水师营地下水初始水位的计算及地下水流场的预测   总被引:1,自引:0,他引:1  
赵培迎  王彦  刘健 《水文》2000,20(3):5-9
利用对偏微分方程逆问题的数值求解,给出了由一组抽水产测水位值计算地下水初始水位以及由二组抽水井实测水位值估算总补给量的方法。在此基础上建立了对地下水流场进行预测的数值方法。并对水师营地下水流场进行了预测,其预测结果与实测值基本吻合。此方法可在类似地下水资源评估和地下水流场计算中推广应用。  相似文献   

2.
 This paper presents the results of field tests of hydrologic parameters in a landfill and the results of numerical simulation to find the efficiency of the pumping method to reduce leachate levels in the landfill. The field hydraulic conductivity and storativity of waste and buried cover soils in the landfill are measured by pumping and slug tests. The hydrologic condition inside the landfill is first calibrated using the drawdown-time curve obtained from the pumping test, and the flow behavior of leachate during pumping in the landfill, when various layers of waste and buried cover soil exist, is analyzed through three-dimensional numerical simulation of flow. The results of the field investigation show that the buried cover soil of low hydraulic conductivity forms an impermeable layer preventing the downward flow of leachate and upward flow of landfill gas. The hydraulic conductivities of the pumping test and slug tests were quite close on the same order of magnitude. It was also possible to match the drawdown-time data of the field tests with those of the model using input data close to the hydrologic property obtained from the field tests. The numerical flow analysis showed that pumping was possible up to 120 tons/day for a single well without a drain, while the pumping rate could be increased to 300 tons/day for the same well with the drain. From the vertical section of the flow vector with a horizontal drain, the barrier role of buried cover soil is identified, which was proposed by examining the water contents of the disposed cover soil and waste in the field. Received: 15 May 1998 · Accepted: 4 January 1999  相似文献   

3.
4.
李霞  文章  梁杏  马腾  陈晨 《地球科学》2017,42(5):743-750
含水层的水文地质参数是进行地下水资源计算、地下水污染防控等所必需的基础数据,结合数值模拟技术进行含水层参数反演很有必要.按照1:5万水文地质调查规范在江汉平原仙桃市杨林尾镇复兴水厂不同含水层位开展抽水试验,包括深层含水层单孔抽水试验以及浅层含水层中群孔(2孔)抽水试验.对于单孔抽水试验,应用第1类越流系统井流理论进行参数反演;对于群孔抽水试验,推导了特定综合井函数,并利用特定标准曲线匹配法和直线图解法求解了含水层参数.随后利用FEFLOW软件建立了相应数值模型,拟合了含水层参数.结果表明:浅层含水层的渗透系数变化范围为21.66~54.00 m/d,贮水率变化范围为1.28×10-5~8.00×10-4 m-1;深层含水层渗透系数变化范围为1.27~7.00 m/d,贮水率变化范围为3.90×10-6~5.00×10-6 m-1.对于深层承压含水层而言,越流补给量较大.采用数值模拟方法结合抽水试验数据求参,综合考虑了含水层结构,拟合效果好,所得结果更加可靠.   相似文献   

5.
A whirlpool foundation pit is a small-diameter, deep circular pit. Because of its depth and small diameter, a large drawdown is required, and a limited number of wells can be installed inside the pit. During excavation, partially penetrating wells inside and outside the foundation pit have to be installed to lower the water level when the aquifer is too thick. However, partially penetrating wells near partially penetrating curtains cannot be treated by analytical methods. Therefore, it is necessary to use numerical methods to predict dewatering during excavation. Field experiments were performed on whirlpool foundation pit 1880 of Baosteel Group, Shanghai, China, to obtain pumping rates and drawdown, pumping with a single well and two wells in the confined aquifer. The results indicate that the drawdown inside the pit induced by pumping wells outside the foundation pit was small, whereas it was large for pumping wells inside the pit. The pumping wells inside and outside the pit had to be combined to lower the water level. A three-dimensional numerical model was developed to simulate the dewatering process. The hydraulic conductivities of the confined aquifers were inversed by using the pumping tests. Operation schedules were simulated with the corrected model for different combinations of wells inside and outside the pit. The results suggest that different schedules and operation conditions affect drawdown. The monitored results during dewatering indicate that the simulation and field measurements were in agreement. The results can be applied to similar situations.  相似文献   

6.
The Arizona Department of Transportation (ADOT) is preparing to upgrade State Route 260 between Payson and Heber. It is estimated that a total of about one million cubic meters of water will be required for embankment construction during a period of about 84 months to upgrade the first 33.8 km of the highway. ADOT is investigating various sources of construction water for use in the highway improvement project, including groundwater resources along the highway corridor. A region known as the RV site, underlain by fractured granite, is located 12.9 km east of Payson. The site includes three springs, a creek and several wells. Several boreholes and observation wells were made to a maximum depth of 157 m to obtain fracture data and to conduct pumping tests with monitoring. Fracture data recorded by acoustic televiewer logs were used to build a fracture network model for the rock mass. Results of a 24-hour and a 7-day pumping tests were used to calibrate hydraulic parameters of a finite element discrete fracture fluid flow model considering the region as a heterogeneous, anisotropic, fractured medium. A 38-day multi-well pumping test was used to validate the calibrated numerical model. The calibrated model showed the capability to provide reasonably accurate predictions for new pumping tests conducted in the same well field. The validated model was then used to simulate pumping exceeding a 7 year period under different scenarios incorporating different sets of boundary conditions and different pumping rates at multi-wells, with and without recharge, to evaluate the yield of the aquifer and to assess the effect of long-term pumping on the environment. The results indicated that (a) the combined yield of the wells in the RV site is sufficient to meet the water demand for the ADOT highway project and (b) the water levels in the well field would decline between 3.0 and 7.6 m after one year of pumping and by 12.2 to over 30.5 m during the life of the project.  相似文献   

7.
Hydraulic conductivity (K) for an alluvial system in a riverbank filtration area in Changwon City, South Korea, has been studied using grain-size distribution, pumping and slug tests, and numerical modeling. The alluvial system is composed of layers: upper fine sand, medium sand, lower fine sand, and a highly conductive sand/gravel layer at the base. The geometric mean of K for the sand/gravel layer (9.89?×?10?4 m s?1), as determined by grain-size analyses, was 3.33 times greater than the geometric mean obtained from pumping tests (2.97?×?10?4 m s?1). The geometric mean of K estimates obtained from slug tests (3.08?×?10?6 m s?1) was one to two orders of magnitude lower than that from pumping tests and grain-size analyses. K estimates derived from a numerical model were compared to those derived from the grain-size methods, slug tests and pumping tests in order to determine the degree of deviation from the numerical model. It is considered that the K estimates determined by the slug tests resemble the uppermost part of the alluvial deposit, whereas the K estimates obtained by grain-size analyses and pumping tests are similar to those from the numerical model for the sand/gravel layer of the riverside alluvial system.  相似文献   

8.
Groundwater responses to tide fluctuations in different hydrogeological situations have been investigated for many years. Various solutions have been derived using the assumption that tides are composed of sinusoidal components, neglecting non-periodic variables. This approach has resulted in the introduction of some inaccuracy in predictions of groundwater responses to sea-level variation. To resolve this problem, this study used the Fourier sine transform method to derive an analytical solution based on the measured sea-level boundary. Compared with an analytical solution based on a sinusoidal assumption and a numerical solution generated by MODFLOW, this solution provided better performance in groundwater-level prediction in a coastal confined aquifer in Zhuhai City, China. The hydrogeological parameters estimated by the three aforementioned methods fitted well with those estimated by field surveys and pumping tests. The introduced analytical solution not only reflects the physical mechanisms of tide-induced groundwater-level fluctuation, but also reveals the non-periodic fluctuation of groundwater level caused by sea-level variation. This solution may also be used to evaluate groundwater responses to random mechanical stresses.  相似文献   

9.
以某地下水源热泵系统工程为例,依据工程场地实际抽水-回灌试验数据,建立研究区地下水流数值模拟模型,分析该地区适宜的井群布置方案,并定量研究不同井群布置方案对地下水流场的影响范围与程度,为确定合理的井群布置方案提供技术支撑。研究表明:对于同一含水层回灌,随着抽水-回灌时间的延长,就有利于抽水-回灌能力及尽量减小对周边地下水开采的影响而言,抽水井、回灌井交叉布置,部分回灌井集中布置的方案较为合理。  相似文献   

10.
Pumping tests data interpretation is of major importance in groundwater engineering. It is traditionally performed in a subjective manner by means of standard type curves. In this paper, an automatic interpretation of time-drawdown data has been proposed based on two algorithms, the real-coded genetic algorithm and differential evolution. The proposed approaches combine metaheuristic algorithms with an appropriate analytical drawdown solution depending upon the nature of the considered aquifer system, leaky or naturally fractured rock aquifers. The standard error of estimate (SEE) was used as a performance criterion to evaluate the discrepancies between predicted and observed drawdown data in different pumping time periods. Both of the proposed metaheuristic algorithms provide accurate aquifer parameters. For all analyzed pumping tests data, the differential evolution yielded the most accurate results with an improvement in SEE values ranged from 0.2 to 50% compared to previously published results, and exhibits speed and robustness. Furthermore, a new full range numerical evaluation of the Hantush well function based on a tanh-sinh quadrature scheme has been proposed. Our results indicate that our method is accurate, since the maximum relative error was found to be equal to 0.00036%, and practical, since it is free from special functions and could be easily incorporated within an optimization technique to analyze transient time-drawdown data.  相似文献   

11.
Groundwater monitoring and pumping wells set in anoxic aquifers require attention to keep the groundwater free of dissolved oxygen (DO). In properly constructed monitoring or pumping wells, two processes can however still introduce oxygen to anoxic groundwater: (1) permeation of oxygen through polymer materials such as silicone, PVC, HDPE or Teflon, and (2) thermally driven convection, which can occur in all types of piezometers or wells, regardless of construction material, when the water table or pressure head is close (<10 m) to the land surface. Here, field measurements (temperature and DO well loggings) from a monitoring well in Bilthoven, the Netherlands, are combined with analytical and numerical modelling to investigate the role of both processes on oxygenation of anoxic groundwater in wells. The results of numerical and analytical modeling show that both permeation and convection can introduce oxygen into anoxic wells to near saturation concentrations. In the field data gathered, convection is primarily responsible for oxygen intrusion up to a depth of around 12 m. Oxygen intrusion through convection and permeation in monitoring and pumping wells may influence groundwater sampling and analyses, and may contribute to well clogging, depending on site conditions. The combination of field and modelling provides new insights into these processes, which can be used for both groundwater sampling and pumping well design.  相似文献   

12.
先存断裂对抽水沉降及地裂缝活动影响的数值模拟   总被引:2,自引:0,他引:2  
过度抽取地下水对断层构造型地裂缝的加剧作用是很明显的,但具体的作用机制却很复杂,过去的研究多是简单的定性分析,数值模拟和定量计算少有报道。笔者采用比奥(Biot)固结渗流理论和基于A、B面接触判断的库仑滑动和张裂的接触面单元,对抽水作用下地裂缝的活动进行了数值模拟,初步探讨了抽水活动引发和加剧地裂缝活动的机制。结果表明:抽水作用下抽水井周围水平应力场发生近井区挤压、远井区拉张的变化,当拉张区内的拉应力超过土体抗拉强度时将会出现自上而下的张裂缝;先存断裂的存在将影响应力变化的模式,同时由于断裂的软弱性,使得地层容易沿其发生滑动或拉裂,从而加剧地裂缝的活动;先存断裂对地面沉降和地裂缝具有诱导、隔离和放大的作用。  相似文献   

13.
14.
南通市南山湖综合楼基坑工程降水数值模拟分析   总被引:1,自引:1,他引:0       下载免费PDF全文
殷宝兵  周爱兆  姜彬霖 《探矿工程》2017,44(10):61-65,69
基坑降水的成功与否,关系到整个基坑的安全。南通市南山湖综合楼基坑开挖过程中虽建立了止水帷幕,但仍需对基坑降水的方案进行安全评估。采用MIDAS/GTS数值分析软件建立三维渗流模型,通过对现场单井抽水试验进行模拟分析,综合地勘报告中室内试验渗透系数和抽水试验的渗透系数,反向推演出符合工程实际的渗流边界函数和渗透系数;然后利用反推得到的计算参数,建立三维渗流模型,模拟群井抽水状态下水位降深与时间的变化关系,对群井降水效果进行分析,验证降水井设计是否合理,指导基坑土方的开挖。  相似文献   

15.
垃圾填埋场抽水试验及降水方案设计   总被引:2,自引:0,他引:2  
张文杰  陈云敏 《岩土力学》2010,31(1):211-215
垃圾填埋场中的渗滤液水位过高会引发一系列环境和稳定问题,工程上可用竖井抽水降低渗滤液水位。通过在填埋场现场进行抽水试验,确定垃圾土的渗透系数和抽水影响半径,在此基础上对填埋场降水的瞬态流问题进行有限元模拟,分析了抽水井口径和间距对填埋场降水的影响,提出了降水方案的设计步骤和方法。抽水试验表明,现场垃圾的渗透系数约为3.6×10-4cm/s,抽水影响半径约为20m。数值分析表明,井径的变化对于降水效果影响不大,而合理选择抽水井间距对降水十分关键。进行抽水方案设计时,应首先根据工期和降水幅度要求计算井间距,按井的出水速度选择水泵,再根据水泵确定井径,最后根据井径和过滤层形式确定钻孔尺寸并选择钻机。  相似文献   

16.
苏锡常地区是我国经济最发达的地区之一。多年来,该地区由于超量开采深层地下水已经引起了严重的地质灾害。在当前严禁开采深层地下水的形势下,对该地区的浅层地下水资源进行科学评价,查明该地区浅层地下水的开发潜力具有十分重要的意义。本文采用GMS软件对常州市滆湖典型地块浅层地下水进行了精细的数值模拟,经模型识别和校正之后,对典型地块的浅层地下水可开采量做出评价。本次对浅层地下水的数值模拟在苏锡常地区内尚属首次,模拟结果可为今后全区合理开发利用浅层微承压地下水提供依据。  相似文献   

17.
针对台兰河地下水库大口径辐射井抽水效果的数值模拟问题,在分析了大口径辐射井渗流行为基础上,提出了应用辐射井子结构法和子结构开关器等辐射井精细模拟技术,并联用改进的截止负压法、迭代增量法和求解大型稀疏矩阵的预处理共轭梯度算法进行有辐射井影响的地下水非稳定渗流场的有限元分析。应用自主研发的三维可视化渗流有限元计算软件GWSS对台兰河地下水库辐射井抽水试验过程中的非稳定渗流场进行了数值模拟研究。研究结果表明:所有观测井计算水位的平均绝对误差为0.22 m,单井水位的平均误差最大值为 0.40 m,最小值为0.02 m,各观测井地下水位的模拟值与实测值的变化趋势吻合较好。经验证算法的合理性和程序的可靠性较好。提出的辐射井子结构法可以精细模拟辐射井的渗流行为和局部精细渗流场,可用于分析辐射井抽水过程中的地下水非稳定渗流变化及取水效率评价。  相似文献   

18.
利用设计建造的抽水试验装置,采取多项潜水及承压水的抽水试验,获得大量的抽水井周围饱水介质场三维动态观测数据。试验发现:无论是潜水还是承压水状态,抽水井附近观测井的水位变化,均具有距抽水井愈远愈高、愈近愈低的漏斗状分布,抽水井附件的地下水位降落漏斗是显著的;同时发现每个观测井不同高度上的观测点的水位,均呈现上高下低的特征,说明地下水具有由上到下的运动分量,地下水由周边的供水边界向抽水井聚集运移时,运动方向是下斜向的,潜水如此,承压水也如此。分析认为,这是水头压力与水体自身重力同时起作用的结果。由此推断,在抽水时,靠近承压水含水层顶板存在强势水流,且越靠近补给源,这种强势水流越强。  相似文献   

19.
Global curve-fitting method (GCFM) is regarded as an effective approach in hydrogeological parameter estimation, as it integrates and uses pumping data and water recovery data of a transient pumping test for parameter estimation. The impacts of pumping duration on hydrogeological parameter estimation by GCFM were investigated in the present study using 2 in situ pumping tests and 24 simulated transient pumping tests. Empirical formulas for determining the optimal pumping duration were derived. The study results suggest that pumping duration will have impacts on the accuracy of hydrogeological parameter estimation. When pumping duration is longer than a certain period, relative errors of hydrogeological parameter estimation keep relatively stable within an acceptable limit. Therefore, it is unnecessary to continue the pumping for a very long time after the groundwater level has become stable. When the change rate of drawdown over time (γ) in an observation well located within a distance of 100 m to the pumping well reaches 0.134, the pumping can be stopped. If there are more than one observation wells in a pumping test, the smallest γ value should be selected to determine the optimal pumping duration. This research is meaningful in the instruction of pumping tests, and will reduce test costs greatly.  相似文献   

20.
水力层析抽水实验可以高精度刻画非均质含水层渗透系数分布,但野外成本高,需要对抽水试验进行优化.通过构建三维非均质含水层砂箱,开展水力层析抽水实验,探讨不同抽水组数和先验信息对刻画渗透系数的影响.分别利用不同抽水组数和融入42个井段岩心渗透系数作为先验信息,对渗透系数场进行估算,并用以预测独立抽水实验过程,对比估算结果优...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号