首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
二维街谷地面加热引起的流场特征的水槽实验研究   总被引:5,自引:0,他引:5  
利用拖曳式水槽,采用激光粒子成像速度场测量系统(PIV),模拟了街谷存在地面加热时流场特征;讨论了环境风场对其的影响。我们发现在静风条件下,街谷中环流完全由热力驱动,对流活动可伸展至街谷上方;在建筑物层顶以上,也可发现水平和垂直方向的运动。这些对流活动有助于基本风场为零时,街谷内外动量和物质的交换。当街谷较宽时,对流形成的涡旋可能为两个以上,形态较为复杂并随时间变化,当街谷变窄时,涡旋蜕化成只有一个。当有弱环境风场存在时,街谷中的对流呈现为一个主涡旋,随着风速增加,涡旋形状更加规则,其中心并向下风向移动。  相似文献   

2.
Water tank experiments are carried out to investigate the convection flow induced by bottom heating and the effects of the ambient wind on the flow in non-symmetrical urban street canyons based on the PIV (Particle Image Visualization) technique. Fluid experiments show that with calm ambient wind,the flows in the street canyon are completely driven by thermal force, and the convection can reach the upper atmosphere of the street canyon. Horizontal and vertical motions also appear above the roofs of the buildings. These are the conditions which favor the exchange of momentum and air mass between the street canyon and its environment. More than two vortices are induced by the convection, and the complex circulation pattern will vary with time in a wider street canyon. However, in a narrow street canyon, just one vortex appears. With a light ambient wind, the bottom heating and the associated convection result in just one main vortex. As the ambient wind speed increases, the vortex becomes more organized and its center shifts closer to the leeward building.  相似文献   

3.
A validated large-eddy simulation model was employed to study the effect of the aspect ratio and ground heating on the flow and pollutant dispersion in urban street canyons. Three ground-heating intensities (neutral, weak and strong) were imposed in street canyons of aspect ratio 1, 2, and 0.5. The detailed patterns of flow, turbulence, temperature and pollutant transport were analyzed and compared. Significant changes of flow and scalar patterns were caused by ground heating in the street canyon of aspect ratio 2 and 0.5, while only the street canyon of aspect ratio 0.5 showed a change in flow regime (from wake interference flow to skimming flow). The street canyon of aspect ratio 1 does not show any significant change in the flow field. Ground heating generated strong mixing of heat and pollutant; the normalized temperature inside street canyons was approximately spatially uniform and somewhat insensitive to the aspect ratio and heating intensity. This study helps elucidate the combined effects of urban geometry and thermal stratification on the urban canyon flow and pollutant dispersion.  相似文献   

4.
Using a computational fluid dynamics(CFD)model,the effects of street-bottom and building-roof heating on flow in three-dimensional street canyons are investigated.The building and street-canyon aspect ratios are one.In the presence of street-bottom heating,as the street-bottom heating intensity increases,the mean kinetic energy increases in the spanwise street canyon formed by the upwind and downwind buildings but decreases in the lower region of the streamwise street canyon.The increase in momentum due to buoyancy force intensifies mechanically induced flow in the spanwise street canyon.The vorticity in the spanwise street canyon strengthens.The temperature increase is not large because relatively cold above-roof-level air comes into the spanwise street canyon.In the presence of both street-bottom and building-roof heating,the mean kinetic energy rather decreases in the spanwise street canyon.This is caused by the decrease in horizontal flow speed at the roof level,which results in the weakening of the mean flow circulation in the spanwise street canyon.It is found that the vorticity in the spanwise street canyon weakens.The temperature increase is relatively large compared with that in the street-bottom heating case,because relatively warm above-roof-level air comes into the spanwise street canyon.  相似文献   

5.
Urban surface and radiation processes are incorporated into a computational fluid dynamics (CFD) model to investigate the diurnal variation of flow in a street canyon with an aspect ratio of 1. The developed CFD model predicts surface and substrate temperatures of the roof, walls, and road. One-day simulations are performed with various ambient wind speeds of 2, 3, 4, 5, and 6 ms−1, with the ambient wind perpendicular to the north–south oriented canyon. During the day, the largest maximum surface temperature for all surfaces is found at the road surface for an ambient wind speed of 3 ms−1 (56.0°C). Two flow regimes are identified by the vortex configuration in the street canyon. Flow regime I is characterized by a primary vortex. Flow regime II is characterized by two counter-rotating vortices, which appears in the presence of strong downwind building-wall heating. Air temperature is relatively low near the downwind building wall in flow regime I and inside the upper vortex in flow regime II. In flow regime II, the upper vortex expands with increasing ambient wind speed, thus enlarging the extent of cool air within the canyon. The canyon wind speed in flow regime II is proportional to the ambient wind speed, but that in flow regime I is not. For weak ambient winds, the dependency of surface sensible heat flux on the ambient wind speed is found to play an essential role in determining the relationship between canyon wind speed and ambient wind speed.  相似文献   

6.
城市湍流边界层内汽车尾气扩散规律数值模拟研究   总被引:2,自引:1,他引:1  
吕萍  袁九毅  张文煜 《高原气象》2005,24(2):167-172
以纳维斯托克斯方程组、大气平流扩散方程、湍流动能及湍流动能耗散率方程组为基础.采用伪不定常方法,建立了一个数值模式.利用该模式列城市湍流边界层内流场结构及汽车排放污染物扩散规律进行了研究。结果表明:街谷内会形成一个涡旋型流场.汽车排放污染物浓度在地面及建筑物背风面产生堆积,且其沿高度方向的梯度变化在背风面大.迎风而小。随着街谷两侧建筑物屋顶风速的增大,峡谷内形成的涡旋流场的强度增大,污染物扩散速率增大:当屋顶来流与街道之间的夹角逐渐增大时.涡旋中心位置由街道中心偏向于背风面及更高层且污染物扩散速度加快。  相似文献   

7.
An approximate sky view factor (SVF) has been developed, which is capable of estimating the mean rate of net longwave radiant energy loss from urban street canyons. Reduced scale models of typical canyon geometries were used in outdoor tests to verify the predictions of radiant fluxes obtained using the proposed SVF. Air-surface temperature differences from the scale models are used together with hypothesized within-canyon airflow patterns to determine some quantitative characteristics of the wind field in canyons. Simple correlations are proposed for the relationship between mean in-canyon and pedestrian-level flow speeds on the one hand, and the ambient (above roof-level) wind speed on the other hand. As expected, the height/width ratio of a canyon controls the form and magnitude of the flow within.  相似文献   

8.
Our study employed large-eddy simulation (LES) based on a one-equation subgrid-scale model to investigate the flow field and pollutant dispersion characteristics inside urban street canyons. Unstable thermal stratification was produced by heating the ground of the street canyon. Using the Boussinesq approximation, thermal buoyancy forces were taken into account in both the Navier–Stokes equations and the transport equation for subgrid-scale turbulent kinetic energy (TKE). The LESs were validated against experimental data obtained in wind-tunnel studies before the model was applied to study the detailed turbulence, temperature, and pollutant dispersion characteristics in the street canyon of aspect ratio 1. The effects of different Richardson numbers (Ri) were investigated. The ground heating significantly enhanced mean flow, turbulence, and pollutant flux inside the street canyon, but weakened the shear at the roof level. The mean flow was observed to be no longer isolated from the free stream and fresh air could be entrained into the street canyon at the roof-level leeward corner. Weighed against higher temperature, the ground heating facilitated pollutant removal from the street canyon.  相似文献   

9.
The impact of diurnal variations of the heat fluxes from building and ground surfaces on the fluid flow and air temperature distribution in street canyons is numerically investigated using the PArallelized Large-eddy Simulation Model (PALM). Simulations are performed for a 3 by 5 array of buildings with canyon aspect ratio of one for two clear summer days that differ in atmospheric instability. A detailed building energy model with a three-dimensional raster-type geometry—Temperature of Urban Facets Indoor-Outdoor Building Energy Simulator (TUF-IOBES)—provides urban surface heat fluxes as thermal boundary conditions for PALM. In vertical cross-sections at the centre of the spanwise canyon the mechanical forcing and the horizontal streamwise thermal forcing at roof level outweigh the thermal forces from the heated surfaces inside the canyon in defining the general flow pattern throughout the day. This results in a dominant canyon vortex with a persistent speed, centered at a constant height. Compared to neutral simulations, non-uniform heating of the urban canyon surfaces significantly modifies the pressure field and turbulence statistics in street canyons. Strong horizontal pressure gradients were detected in streamwise and spanwise canyons throughout the day, and which motivate larger turbulent velocity fluctuations in the horizontal directions rather than in the vertical direction. Canyon-averaged turbulent kinetic energy in all non-neutral simulations exhibits a diurnal cycle following the insolation on the ground in both spanwise and streamwise canyons, and it is larger when the canopy bottom surface is paved with darker materials and the ground surface temperature is higher as a result. Compared to uniformly distributed thermal forcing on urban surfaces, the present analysis shows that realistic non-uniform thermal forcing can result in complex local airflow patterns, as evident, for example, from the location of the vortices in horizontal planes in the spanwise canyon. This study shows the importance of three-dimensional simulations with detailed thermal boundary conditions to explore the heat and mass transport in an urban area.  相似文献   

10.
Scalar Fluxes from Urban Street Canyons Part II: Model   总被引:1,自引:1,他引:0  
A practical model is developed for the vertical flux of a scalar, such as heat, from an urban street canyon that accounts for variations of the flow and turbulence with canyon geometry. The model gives the magnitude and geometric dependence of the flux from each facet of the urban street canyon, and is shown to agree well with wind-tunnel measurements described in Part I. The geometric dependence of the flux from an urban street canyon is shown to be determined by two physical processes. Firstly, as the height-to-width ratio of the street canyon increases, so does the roughness length and displacement height of the surface. This increase leads to a reduction in the wind speed in the inertial sublayer above the street canyons. Since the speed of the circulations in the street are proportional to this inertial sublayer wind speed, the flux then reduces with the inertial sublayer wind speed. This process is dominant at low height-to-width ratios. Secondly, the character of the circulations within the street canyon also varies as the height-to-width ratio increases. The flow in the street is partitioned into a recirculation region and a ventilated region. When the street canyon has high height-to-width ratios the recirculation region occupies the whole street canyon and the wind speeds within the street are low. This tendency decreases the flux at high height-to-width ratios. These processes tend to reduce the flux density from the individual facets of the street canyon, when compared to the flux density from a horizontal surface of the same material. But the street canyon has an increased total surface area, which means that the total flux from the street canyon is larger than from a horizontal surface. The variations in scalar flux from an urban street canyon with geometry is over a factor of two, which means that the physical mechanisms responsible should be incorporated into energy balance models for urban areas.  相似文献   

11.
Wind-tunnel studies of dispersion processes of traffic exhaust in urban street canyons with tree planting were performed and tracer gas concentrations using electron capture detection (ECD) and flow fields using laser Doppler velocimetry (LDV) were measured. It was found that tree planting reduces the air exchange between street canyons and the ambience. In comparison to treeless street canyons, higher overall pollutant concentrations and lower flow velocities were measured. In particular, for perpendicular approaching wind, markedly higher concentrations at the leeward canyon wall and slightly lower concentrations at the windward canyon wall were observed. Furthermore, a new approach is suggested to model porous vegetative structures such as tree crowns for small-scale wind-tunnel applications. The approach is based on creating different model tree crown porosities by incorporating a certain amount of wadding material into a specified volume. A significant influence of the crown porosity on pollutant concentrations was found for high degrees of porosity, however, when it falls below a certain threshold, no further changes in pollutant concentrations were observed.  相似文献   

12.
吕萍  袁九毅  张文煜 《高原气象》2004,23(4):534-539
利用数值模拟方法研究了微尺度街道峡谷范围内街谷几何结构及街道两侧建筑物高度对称性对街谷内流场及机动车排放污染物扩散规律的影响。结果表明:当街道峡谷高宽比>2.1时,街谷内的流场结构由一个完整的垂直涡旋变为上下两个反向运动的强弱不同的垂直涡旋。各类型街谷内污染物扩散水平从强到弱依次为迎风面建筑物高度大于背风面建筑物高度的街道峡谷,迎风面建筑物高度小于背风面建筑物高度的街道峡谷;平行型街道峡谷。  相似文献   

13.
This study summarizes the effects of avenues of trees in urban street canyons on traffic pollutant dispersion. We describe various wind-tunnel experiments with different tree-avenue models in combination with variations in street-canyon aspect ratio W/H (with W the street-canyon width and H the building height) and approaching wind direction. Compared to tree-free street canyons, in general, higher pollutant concentrations are found. Avenues of trees do not suppress canyon vortices, although the air ventilation in canyons is hindered significantly. For a perpendicular wind direction, increases in wall-average and wall-maximum concentrations at the leeward canyon wall and decreases in wall-average concentrations at the windward wall are found. For oblique and perpendicular wind directions, increases at both canyon walls are obtained. The strongest effects of avenues of trees on traffic pollutant dispersion are observed for oblique wind directions for which also the largest concentrations at the canyon walls are found. Thus, the prevailing assumption that attributes the most harmful dispersion conditions to a perpendicular wind direction does not hold for street canyons with avenues of trees. Furthermore, following dimensional analysis, an estimate of the normalized wall-maximum traffic pollutant concentration in street canyons with avenues of trees is derived.  相似文献   

14.
The effects of building-roof cooling on flow and air temperature in 3D urban street canyons are numerically investigated using a computational fluid dynamics (CFD) model. The aspect ratios of the building and street canyon considered are unity. For investigating the building-roof cooling effects, the building-roof temperatures are systematically changed. The traditional flow pattern including a portal vortex appears in the spanwise canyon. Compared with the case of the control run, there are minimal differences in flow pattern in the cases in which maximum building-roof cooling is considered. However, as the building roof becomes cooler, the mean kinetic energy increases and the air temperature decreases in the spanwise canyon. Building-roof cooling suppresses the upward and inward motions above the building roof, resultantly increasing the horizontal velocity near the roof level. The increase in wind velocity above the roof level intensifies the secondarily driven vortex circulation as well as the inward (outward) motion into (out of) the spanwise canyon. Finally, building-roof cooling reduces the air temperature in the spanwise canyon, supplying much relatively cool air from the streamwise canyon into the spanwise canyon.  相似文献   

15.
Among several urban design parameters, the height-to-width ratio (H/W) and orientation are important parameters strongly affecting thermal conditions in cities. This paper quantifies changes in thermal comfort due to typical urban canyon configurations in Campinas, Brazil, and presents urban guidelines concerning H/W ratios and green spaces to adapt urban climate change. The study focuses on thermal comfort issues of humans in urban areas and performs evaluation in terms of physiologically equivalent temperature (PET), based on long-term data. Meteorological data of air temperature, relative humidity, wind speed and solar radiation over a 7-year period (2003–2010) were used. A 3D street canyon model was designed with RayMan Pro software to simulate the influence of urban configuration on urban thermal climate. The following configurations and setups were used. The model canyon was 500 m in length, with widths 9, 21, and 44 m. Its height varied in steps of 2.5 m, from 5 to 40 m. The canyon could be rotated in steps of 15°. The results show that urban design parameters such as width, height, and orientation modify thermal conditions within street canyons. A northeast–southwest orientation can reduce PET during daytime more than other scenarios. Forestry management and green areas are recommended to promote shade on pedestrian areas and on façades, and to improve bioclimate thermal stress, in particular for H/W ratio less than 0.5. The method and results can be applied by architects and urban planners interested in developing responsive guidelines for urban climate issues.  相似文献   

16.
为研究机动车辆排出的污染物在大气中的扩散规律,在北京做了小风条件下的街谷示踪试验。当楼顶风速u接近或大于1米/秒时,街谷内可形成一稳定的原生涡;u<0.6米/秒时原生涡将消失。对于楼之间空间较小的街谷,背风面和迎风面的示踪剂浓度平均比值可达8。浓度值沿楼层高度无明显变化;由于快车路旁松墙的阻挡和抬升作用,可能造成沿高度方向楼层中段的浓度偏高。在街谷外,除下风方路面上有一按下风距离的负幂指数衰减的浓度分布外,上风方路面上也有一按较大负幂指数衰减的分布。根据上述试验,给出了用以预测街谷中机动车辆排出的惰性气体污染物的扩散模式;模式中,对原生涡和小尺度湍流,做了分别处理。  相似文献   

17.
城市街道峡谷对称性对内部气流场的影响研究   总被引:4,自引:1,他引:3       下载免费PDF全文
应用雷诺应力湍流模型,模拟了不同高度比的城市街道峡谷的气流场。结果表明:峡谷的对称性对其内部气流场有显著影响。前高后低型峡谷下部为逆时针旋涡,上部为顺时针旋涡,峡谷越深,流场发展的越充分;峡谷内部墙面存在明显的驻点。前低后高型峡谷只存在一个大的顺时针旋涡,随着峡谷的加深,内部气流速率有减小的趋势;峡谷达到一定深度后出现驻点。对称型峡谷内部形成了顺时针旋涡,强度不大;随着峡谷的加深,内部流场转为一顺一反2个旋涡的二元结构;仅当峡谷很深时才出现明显驻点。前低后高型峡谷的气流场形式更有利于污染物的迁移、扩散,在城市规划中应尽量结合主导风向设计这类建筑布局。  相似文献   

18.
A model for the calculation of the turbulence flow field and air pollutant concentrations in urban canyons is developed. A two-dimensional set of hydrodynamical equations and a threedimensional diffusion equation are solved numerically with a personal computer. Different boundary conditions were investigated. Three flow regimes were found: without vortex, with one vortex, and with two vortexes, within an urban canyon. The influence of building density and wind speed components along the street was also investigated.  相似文献   

19.
The transfer processes within and above a simulated urban street canyon were investigated in a generic manner. Computational fluid dynamics (CFD) was used to aid understanding and to produce some simple operational parameterisations. In this study we addressed specifically the commonly met situation where buoyancy effects arising from elevated surface temperatures are not important, i.e. when mechanical forces outweigh buoyancy forces. In a geophysical context this requires that some suitably defined Richardson number is small. From an engineering perspective this is interpreted as the important case when heat transfer within and above urban street canyons is by forced convection. Surprisingly, this particular scenario (for which the heat transfer coefficient between buildings and the flow is largest), has been less well studied than the situation where buoyancy effects are important. The CFD technique was compared against wind-tunnel experiments to provide model evaluation. The height-to-width ratio of the canyon was varied through the range 0.5–5 and the flow was normal to the canyon axis. By setting the canyon’s facets to have the same or different temperatures or to have a partial temperature distribution, simulations were carried out to investigate: (a) the influence of geometry on the flow and mixing within the canyon and (b) the exchange processes within the canyon and across the canyon top interface. Results showed that the vortex-type circulation and turbulence developed within the canyon produced a temperature distribution that was, essentially, spatially uniform (apart from a relatively thin near-wall thermal boundary layer) This allowed the temperatures within the street canyon to be specified by just one value T can , the canyon temperature. The variation of T can with wind speed, surface temperatures and geometry was extensively studied. Finally, the exchange velocity u E across the interface between the canyon and the flow above was calculated based on a heat flux balance within the canyon and between the canyon and the flow above. Results showed that u E was approximately 1% of a characteristic wind velocity above the street canyon. The problem of radiative exchange is not addressed but it can, of course, be introduced analytically, or computationally, when necessary.  相似文献   

20.
In order to investigate the microclimatic conditions in a street canyon, a physical model was used to conduct the Joint ATREUS-PICADA Experiment (JAPEX) in situ experimental campaign. Four lines of buildings simulated by steel containers were installed to form three parallel street canyons at 1:5 scale, with width/height aspect ratio approximately 0.40. The reference wind and atmospheric conditions were measured, as well as the flow velocity and direction in the street. Preliminary results concern street canyon ventilation and thermal effects on in-canyon airflow, and show that vortical motions appear for reference wind directions perpendicular to the street axis. The presence of adjacent rows of buildings did not appear to significantly influence the flow character within the canyon for the case of a low aspect ratio corresponding to a skimming flow regime. The flow structure was not significantly affected by the thermal effects although some slight interference occurred in the lower part of the canyon. An analysis of horizontal temperature gradients indicated that a thin boundary layer develops near the heated facade. These facts imply that the thermal effects are considerable only very close to the wall.  相似文献   