首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
This study investigated the thermal regime of shallow groundwater in the Turin area (NW Italy), where the large energy demand has motivated a new interest for renewable sources, such as the use of ground-source heat pumps for domestic heating and cooling. The vertical variability of the groundwater temperature between the ground surface and 10–20 m was detected: deeper temperatures were higher than shallow temperatures in spring, while a decrease with depth occurred in autumn. These variations are connected with the heating and cooling cycles of the ground surface due to the seasonal temperature oscillation. Variations below the seasonal oscillation are likely to be connected with the presence of advective heat transport due to the groundwater flow, according to the hydraulic features of a shallow aquifer. Temperature values mostly ranged between 12 and 14 °C in rural areas, while the values were between 14 and 16 °C below the Turin city. This groundwater warming is attributed to a widespread urban heat island phenomenon linked to warmer land surface temperatures in Turin city. Sparse warm outliers are connected with point heat sources and site-specific conditions of land and subsurface use, which may cause the aquifer temperature to rise. A relatively stable temperature below the seasonal fluctuation zone combined with high productivity and legislated limits for deeper groundwater use represent favourable conditions for a large-scale diffusion of groundwater heat pumps within the shallow aquifer. Moreover, this heat surplus should be regarded as a resource for future geothermal installations.  相似文献   

2.

Urban areas are major contributors to the alteration of the local atmospheric and groundwater environment. The impact of such changes on the groundwater thermal regime is documented worldwide by elevated groundwater temperature in city centers with respect to the surrounding rural areas. This study investigates the subsurface urban heat island (SUHI) in the aquifers beneath the Milan city area in northern Italy, and assesses the natural and anthropogenic controls on groundwater temperatures within the urban area by analyzing groundwater head and temperature records acquired in the 2016–2020 period. This analysis demonstrates the occurrence of a SUHI with up to 3 °C intensity and reveals a correlation between the density of building/subsurface infrastructures and the mean annual groundwater temperature. Vertical heat fluxes to the aquifer are strongly related to the depth of the groundwater and the density of surface structures and infrastructures. The heat accumulation in the subsurface is reflected by a constant groundwater warming trend between +0.1 and?+?0.4 °C/year that leads to a gain of 25 MJ/m2 of thermal energy per year in the shallow aquifer inside the SUHI area. Future monitoring of groundwater temperatures, combined with numerical modeling of coupled groundwater flow and heat transport, will be essential to reveal what this trend is controlled by and to make predictions on the lateral and vertical extent of the groundwater SUHI in the study area.

  相似文献   

3.
城市热岛效应是全球与区域气候变化研究中的焦点问题。基于2001—2012年较长时间序列的北京市MODIS地表温度产品及相关NDVI和反射率产品,给出地表温度时间序列构建方法。基于站点气象观测资料进行的精度验证表明地表温度时间序列构建方法可行,并最终给出城市热岛强度的量化方案。研究选取统计学中X-11-ARIMA时间序列建模方法,分离并分析城市热岛强度时间序列的结构性成分。分析发现,以平均城乡温差为指标的北京城市热岛强度季节性特征明显,与城乡土地利用状况、季节性地表覆盖、地物热特性以及气候因子等联系密切。趋势—循环特征与城市扩张速度及入选城市区域面积相关。以已发生城市热岛区域城乡平均温差为指标的北京城市热岛强度趋势—循环特性在12年间表现平稳。时间序列建模分析提取出不规则变动成分,为定量研究偶然因素对城市热岛的影响提供了可能。  相似文献   

4.
为构建温度示踪方法测算地下水流速技术体系,并应用于区域地下水资源评价,基于最小二乘法和垂向一维非稳定流水-热运移方程数值解法,提出地表暖化情形下地下水流速计算方法,并对雷州半岛东北部地下水流速进行测算。结果表明:研究区域地下水补给速度为0.796m/a,入渗以西北部降水和运河渗漏为主;地下水排泄速度为0.269m/a,排泄入海主要发生在东海岛、南三岛和硵州岛附近。温度示踪解析区域地下水流动情况与地下水位分布情况基本一致,观测和计算地温数据具有较强相关性(R^2>0.50)和较低均方根误差(均值0.748),表明提出方法率定得到的地下水流速具有较强的可靠性。参数敏感性分析结果表明,地质体热扩散率和地表温度均对地温计算结果产生较明显的影响,参数的准确率定对利用地温计算地下水流速十分重要。  相似文献   

5.
The use of renewable energy can be enhanced by utilising groundwater reservoirs for heating and cooling purposes. The urbanisation effect on the peak heating and peak cooling capacity of groundwater in a cold groundwater region was investigated. Groundwater temperatures were measured and energy potentials calculated from three partly urbanised aquifers situated between the latitudes of 60° 25′N and 60° 59′N in Finland. The average groundwater temperature below the zone of seasonal temperature fluctuations was 3–4 °C higher in the city centres than in the rural areas. The study demonstrated that due to warmer groundwater, approximately 50–60 % more peak heating power could be utilized from populated areas compared with rural areas. In contrast, approximately 40–50 % less peak cooling power could be utilised. Urbanisation significantly increases the possibility of utilising local heat energy from groundwater within a wider region of naturally cold groundwater. Despite the warming in urban areas, groundwater still remains attractive as a source of cooling energy. More research is needed in order to determine the long-term energy capacity of groundwater, i.e. the design power, in urbanised areas of cold regions.  相似文献   

6.
Recently, the rate of urbanisation has accelerated due to increasing population density which causes unexpected environmental disturbances and problems. One of the major problems encountered to date is the change in the land use/cover (LULC) structure. Increasing the impervious surface cover has changed microclimatic properties of urbanised areas by altering their thermal characteristics. One of the most important problems facing urban planning today is the phenomena known as the urban heat island (UHI), which is largely due to the changing the character of LULC. In this study, to create a national picture of the UHI structure in Turkey, seven cities, namely Istanbul, Bursa, Ankara, Izmir, Gaziantep, Erzurum and Trabzon, each located in different climatic regions of Turkey, were investigated. The Gaussian fitting technique was applied to characterise the UHI effect in the seven cities in the study. An original contribution of the current study was that the rural reference temperature surface was automatically determined by a proposed algorithm including the automatic masking of input data, as well as the application of iterative Gaussian low-pass filtering during the fitting procedure. Within this context, the daytime and nighttime surface urban heat island (SUHI) effect was modelled and temporally analysed from 1984 to 2011 for all the sub-regions using remote sensing techniques. Furthermore, atmospheric UHI was also investigated using the mobile transect method. The findings from this study suggest that UHI is a major environmental problem in urbanised areas, both atmospheric UHI and SUHI were detected in all cities in the study area, and this problem was found to have rapidly increased from 1984 to 2011. Finally, as inferred from the multiple regression results, it can be concluded that the UHI problem in Turkey might have resulted from the altered LULC structure, as well as anthropogenic pressure on and interference in city planning geometries.  相似文献   

7.
朱巍 《地质与勘探》2024,60(1):113-120
本文就浅层地热能开发利用过程中出现的生态环境和地质环境问题从客观因素和人为因素进行了详细的研究,借助土壤温度的测试和地层冷热平衡的监测,分析在地源热泵运行过程中造成的热污染、地下水位下降、地面沉降、地下水质恶化污染等问题。研究认为长期利用地源热泵开发利用系统,如设计不合理或地下水回灌率低,将破坏地层的冷热平衡。北方地区供暖期大于制冷期时,地层温度将逐年下降,N2O和CH4会集中释放,造成生物生长速度缓慢。地下水源热泵运行时,如地下水回灌困难,将导致地下水资源浪费、水位下降等生态环境问题以及路面塌陷、地面沉降等地质环境问题。供暖期、制冷期运行时间差别较大时,将导致地下水温度的变化,直接影响地下水中污染物的降解,间接影响地下水的水质。抽取、回灌地下水的过程会造成空气中的氧气随之溶解于水中,导致地下水质的变化。通过分析浅层地热能开发利用存在的突出问题和影响因素,可为其科学合理开发利用提供科学依据和技术支撑。  相似文献   

8.
北京地区地下水源热泵利用现状及存在问题   总被引:1,自引:0,他引:1  
本文综合国内外地下水源热泵研究现状,通过对北京地区地下水源热泵利用现状调查分析,重点分析了地下水水源热泵利用过程中存在的不能完全回灌、回灌水温差过大、水井布设不合理等问题。结合北京平原区第四系水文地质条件,分析了不同含水层结构下如何合理布设地下水源热泵系统的用水井,尽量避免水源热泵系统的使用对地下水的影响。  相似文献   

9.
Risk assessment and mapping methodologies for heat waves as frequently occurring hazards in central and southeastern Europe were applied in this study, and the impact of heat waves on the mortality of urban populations was determined as part of the assessment. The methodology for conducting the heat wave risk assessment is based on European Commission’s Guidelines for Risk Assessment and Mapping. The Novi Sad (Serbia) urban area was studied during summer 2015, which was one of the hottest summers in the last few decades. In situ air temperature measurements from urban stations and mortality of urban populations were used. Nocturnal urban heat island (UHI) intensity values between the various built-up zones and natural surrounding areas were used for the hazard level calculation. Temperature data from 9 p.m. to 5 a.m. were used because during the night, the UHI intensity reached its maximum values. The average daily number of deaths by LCZs was used to define the impact level of the vulnerability index. Calculations for both hazard levels were completed during two intensive heat waves (in July and August 2015) when it was expected that there may be a high level of risk. The results and maps show that the urban area is complex, and the heat wave risk on the population is not uniform. The most densely built-up areas (LCZs 2, 5 and 6) have very high or high risk values that are influenced by a higher rate of mortality. The obtained results and maps can be used by local authorities to prevent and mitigate climate-related hazards, for medical institutions as well as urban planners and for ancillary local, regional or national services. According to these results, the local authorities could define hot spots where they can place medical and rescue teams and install points with water supplies, etc.  相似文献   

10.
The impact of groundwater heat pumps on groundwater temperature is simulated by means of a 2D numerical groundwater model in the Leibnitzer Feld aquifer, Austria. The model provides a basis for assessing the regional use of groundwater temperature as an energy source. Since the groundwater table is shallow, the air temperature represents the main source controlling the groundwater temperature. A temperature input function depending on the depth of the groundwater table is delineated from an observed soil temperature profile and the air temperature. Given the diffuse and ubiquitous nature of the heat input, the heat exchange is implemented as a third type boundary condition to enable two-way heat transfer. The temperature of the reinjected water is limited to a decrease of 5 K and an absolute minimum of 5°C by Austrian law. The pumping rates needed to cover the heat requirements of three typical users are determined for selected locations. It is shown that the reduction of the ambient groundwater temperature approximately 300 m downstream of the reinjection wells is less than 0.5°C. Thus it can be concluded that aquifers in similar settings show substantial potential to provide heating and warm water supply for buildings without deteriorating the regional groundwater temperature regime.  相似文献   

11.
The low annual and seasonal variability of the shallow groundwater temperature in the alluvial plain aquifers of the Piemonte region (NW Italy) confirmed the potentiality of the low-enthalpy open-loop groundwater heat pumps (GWHP) diffusion to contribute to the reduction of regional greenhouse gas emissions. The distribution of mean groundwater temperatures ranged from a minimum of 10.3°C to a maximum of 17.9°C with a mean of 14.0°C. Differences among diverse areas were slight according with the modest variations in the general climatic condition. Like the air, temperature distribution of the shallow groundwater temperatures is generally similar to topographic elevations in reverse manner. Higher temperature values recorded were typical of summer months (June, July). On the opposite lower values were measured in January and February. No significant difference phase (time) difference between air and groundwater temperature appeared in the data analysis. Besides air-temperature influence (seasonal variability) seemed strictly connected to the depth to groundwater in the measure point and it was negligible when the value was over 9.5 m. For the application of the open-loop systems, extensive examinations of the hydrogeological local conditions should be conducted at site scale and groundwater heat transport modelling should be developed.  相似文献   

12.
This paper investigates the urban heat island (UHI) characteristics of Shanghai, China, during 1981–2010 using Landsat thematic mapper/multispectral scanner and moderate-resolution imaging spectroradiometer satellite data from the perspectives of time and space, with further analysis of the landscape pattern, the urban heat island effect ratio, and formative factors. The results show the following: (1) From the interannual variation, the secondary-medium temperature area and the medium temperature area are the main bodies of Shanghai UHI, accounting for 67.16–83.69 % of the total area, and have a rising trend over time. (2) From the landscape pattern, the secondary-medium temperature area and the medium temperature area have a dominant position over the whole UHI landscape pattern of Shanghai; the relatively high-temperature area gradually decreases, and its dominance over the whole UHI landscape pattern declines. (3) From the spatial distribution, the pattern in which the urban area initially had complete domination has gradually transformed to become primarily urban area centered and other construction land supplemented with rapid urbanization. Rapid increase of the green land in the urban area has to some extent reduced the UHI characteristics of the Shanghai area in recent years.  相似文献   

13.
The Laguna Lagunillas basin in the arid Andes of northern Chile exhibits a shallow aquifer and is exposed to extreme air temperature variations from 20 to ?25 °C. Between 1991 and 2012, groundwater levels in the Pampa Lagunillas aquifer fell from near-surface to ~15 m below ground level (bgl) due to severe overexploitation. In the same period, local mean monthly minimum temperatures started a declining trend, dropping by 3–8 °C relative to a nearby reference station. Meanwhile, mean monthly maximum summer temperatures shifted abruptly upwards by 2.7 °C on average in around 1996. The observed air temperature downturns and upturns are in accordance with detected anomalies in land-surface temperature imagery. Two major factors may be causing the local climate change. One is related to a water-table decline below the evaporative energy potential extinction depth of ~2 m bgl, which causes an up-heating of the bare soil surface and, in turn, influences the lower atmosphere. At the same time, the removal of near-surface groundwater reduces the thermal conductivity of the upper sedimentary layer, which consequently diminishes the heat exchange between the aquifer (constant heat source of ~10 °C) and the lower atmosphere during nights, leading to a severe dropping of minimum air temperatures. The observed critical water-level drawdown was 2–3 m bgl. Future and existing water-production projects in arid high Andean basins with shallow groundwater should avoid a decline of near-surface groundwater below 2 m bgl and take groundwater-climate interactions into account when identifying and monitoring potential environmental impacts.  相似文献   

14.
北京城市热岛效应的数值试验研究   总被引:2,自引:0,他引:2       下载免费PDF全文
采用数值模拟方法定量分析不同下垫面条件对于北京的城市风场、温度场等的影响,探讨北京城市热岛的形成机理和可能的改善途径。采用区域大气模拟系统MM5,模拟和分析了2000年秋季北京的城市热岛状况。结果显示,MM5模式能较好地模拟北京城市热岛现象,成功再现了城市高温中心及城市热岛环流。MM5模式与陆面过程模型Noah LSM的耦合能在很大程度上改善对热岛效应的模拟。  相似文献   

15.

The progressive electrification of the building conditioning sector in recent years has greatly contributed to reducing greenhouse gas emissions by using renewable energy sources, particularly shallow geothermal energy. This energy can be exploited through open and closed shallow geothermal systems (SGS), and their performances greatly depend on the ground/groundwater temperature, which can be affected by both natural and anthropogenic phenomena. The present study proposes an approach to characterize aquifers affected by high SGS exploitation (not simulated in this work). Characterization of the potential hydro/thermogeological natural state is necessary to understand the regional flow and heat transport, and to identify local thermal anomalies. Passive microseismic and groundwater monitoring were used to assess the shape and thermal status of the aquifer; numerical modeling in both steady-state and transient conditions allowed understanding of the flow and heat transport patterns. Two significant thermal anomalies were detected in a fluvio-glacial aquifer in southern Switzerland, one created by river water exfiltration and one of anthropogenic nature. A favorable time lag of 110 days between river and groundwater temperature and an urban hot plume produced by underground structures were observed. These thermal anomalies greatly affect the local thermal status of the aquifer and consequently the design and efficiency of current and future SGS. Results show that the correct characterization of the natural thermo-hydrogeological status of an aquifer is a fundamental basis for determining the impact of boundary conditions and to provide initial conditions required to perform reliable local thermal sustainability assessments, especially where high SGS exploitation occurs.

  相似文献   

16.
The urban heat island (UHI), together with summertime heat waves, foster’s biophysical hazards such as heat stress, air pollution, and associated public health problems. Mitigation strategies such as increased vegetative cover and higher albedo surface materials have been proposed. Atlanta, Georgia, is often affected by extreme heat, and has recently been investigated to better understand its heat island and related weather modifications. The objectives of this research were to (1) characterize temporal variations in the magnitude of UHI around Metro Atlanta area, (2) identify climatological attributes of the UHI under extremely high temperature conditions during Atlanta’s summer (June, July, and August) period, and (3) conduct theoretical numerical simulations to quantify the first-order effects of proposed mitigation strategies. Over the period 1984–2007, the climatological mean UHI magnitude for Atlanta-Athens and Athens-Monticello was 1.31 and 1.71°C, respectively. There were statistically significant minimum temperature trends of 0.70°C per decade at Athens and −1.79°C per decade at Monticello while Atlanta’s minimum temperature remained unchanged. The largest (smallest) UHI magnitudes were in spring (summer) and may be coupled to cloud-radiative cycles. Heat waves in Atlanta occurred during 50% of the years spanning 1984–2007 and were exclusively summertime phenomena. The mean number of heat wave events in Atlanta during a given heat wave year was 1.83. On average, Atlanta heat waves lasted 14.18 days, although there was quite a bit of variability (standard deviation of 9.89). The mean maximum temperature during Atlanta’s heat waves was 35.85°C. The Atlanta-Athens UHI was not statistically larger during a heat wave although the Atlanta-Monticello UHI was. Model simulations captured daytime and nocturnal UHIs under heat wave conditions. Sensitivity results suggested that a 100% increase in Atlanta’s surface vegetation or a tripling of its albedo effectively reduced UHI surface temperature. However, from a mitigation and technological standpoint, there is low feasibility of tripling albedo in the foreseeable future. Increased vegetation seems to be a more likely choice for mitigating surface temperature.  相似文献   

17.
关中盆地主要城市浅层地热能资源量赋存规律研究   总被引:11,自引:10,他引:1       下载免费PDF全文
具有无污染、可再生、分布广、能量大以及可就近利用等诸多优势的浅层地温能是一种建筑节能的洁净能源,具有广泛的应用前景。根据关中盆地主要城市工程地质、水文地质、环境地质条件等因素,分别建立了每个城市地下水热泵和地埋管热泵系统的适宜分区评价体系,并进行了适宜性综合分区。基于适宜性分区评价结果,对主要城市进行了浅层地热能资源量评价,包括热容量计算、换热功率计算和热能潜力计算,旨在有效地丰富浅层地温能勘察评价与开发利用的理论、奠定浅层地温能广泛开发利用的基础,为改善我国现有能源结构、构建环境友好型社会和节能减排的目标服务。  相似文献   

18.
Information on the distribution of subsurface temperature and hydraulic heads at 24 observation wells in and around the Tokyo Lowland, the eastern part of the Tokyo Metropolitan area, were examined to make clear the relationship between groundwater and the subsurface thermal environment in the urban area. Minimums in temperature–depth logs due to subsurface temperature increasing at shallow parts were recognized in 21 wells. This fact shows subsurface temperature is affected by ground surface warming in almost all of this area. Deeper than minimums, where the effects of surface warming became relatively small, regional variation is observed as follows: high temperatures are shown in the central part to the southern part, and low temperatures shown in the inland to eastern part. The high temperature area corresponds to an area where the lower boundary of groundwater flow is relatively shallow. This area corresponds also to an area with severe land subsidence resulting from excessive groundwater pumping. It is considered that this high temperature area is formed by the effects of upward groundwater flow affected by hydrogeological conditions and pumping. On the other hand, a comparison between past data (1956–1967) and present data (2001–2003) revealed widespread decreasing temperature in the inland area. This is explained by downward groundwater flow based on an analysis of temperature–depth logs. This fact suggests that subsurface temperature is not only increasing from the effects of surface warming but also decreasing from the effects of groundwater environment change due to pumping.  相似文献   

19.
Numerical investigations and a thermohydraulic evaluation are presented for two-well models of an aquifer thermal energy storage (ATES) system operating under a continuous flow regime. A three-dimensional numerical model for groundwater flow and heat transport is used to analyze the thermal energy storage in the aquifer. This study emphasizes the influence of regional groundwater flow on the heat transfer and storage of the system under various operation scenarios. For different parameters of the system, performances were compared in terms of the temperature of recovered water and the temperature field in the aquifer. The calculated temperature at the producing well varies within a certain range throughout the year, reflecting the seasonal (quarterly) temperature variation of the injected water. The pressure gradient across the system, which determines the direction and velocity of regional groundwater flow, has a substantial influence on the convective heat transport and performance of aquifer thermal storage. Injection/production rate and geometrical size of the aquifer used in the model also impact the predicted temperature distribution at each stage and the recovery water temperature. The hydrogeological-thermal simulation is shown to play an integral part in the prediction of performance of processes as complicated as those in ATES systems.  相似文献   

20.
The vertical extension of the urban “heat island” (UHI) has been studied on the basis of long-term data of contact air temperature measurements at three places for the example of Moscow. The existence of steady thermal anomaly related to the city in the form of a UHI in the surface layer at any time of the day and also the existence of a cold layer over it at heights higher than 100 m at night were confirmed. The mean daily altitudinal extension of this anomaly is approximately 300 m.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号