This paper presents a full‐scale thermal remediation of a brownfields site near San Francisco, California. In Situ Thermal Desorption (ISTD) was used for treatment of chlorinated solvents in a tight clay below the water table. The site had contaminants in concentrations indicating that a tetrachloroethene (PCE)‐rich DNAPL was present. A target volume of 5097 m3 of subsurface material to a depth of 6.2 m was treated for a period of 110 d of heating. Energy was delivered through 126 thermal conduction heater borings, and vapors were extracted from a combination of vertical and horizontal vacuum wells. Approximately 2540 kg of contaminants were recovered in the extracted vapors by the end of treatment. The PCE concentration in the clay was reduced from as high as 2700 mg/kg to an average concentration of 0.012 mg/kg within 110 d of heating (a reduction of >99.999%). Similar effectiveness was documented for TCE, cis‐1,2‐DCE, and vinyl chloride. A total of 2.2 million kWh of electric power was used to heat the site. Approximately 45% of this energy was used to heat the subsurface to the target temperature. Another 53% was necessary to boil approximately 41% of the groundwater within the treatment zone, creating approximately 600 pore volumes of steam by the end of the 110‐d heating and treatment period. Steam generation thus occurred within the clay. Partitioning of the contaminants into the steam and its removal comprised the dominant remedial mechanism. The steam migrated laterally toward the ISTD heaters, where it encountered a small dry region adjacent to each of the heaters, which served as a preferential pathway allowing the steam to migrate upward along the heaters to the more permeable vadose zone. There the steam was captured by a system of vertical and horizontal vacuum extraction wells. This vapor removal strategy facilitated effective thermal treatment of the tight clays located below the water table. Features of a robust design are extension of the heaters at least 1.2 m deeper than the treatment depth, and the installation of shallow horizontal vapor collection wells which allow for establishment of pneumatic control.  相似文献   

2.
This paper presents the largest In Situ Thermal Desorption (ISTD) project completed to date. The redevelopment of a former aerospace manufacturing facility adjacent to a commercial airport was the main driver, requiring relatively rapid reduction of several chlorinated volatile organic compounds (CVOC) in a 3.2‐acre source zone. The source zone was divided into four quadrants with differing treatment depths, heated simultaneously using a total of 907 thermal conduction heater wells. Five different depths were selected across the area, according to the depth of contaminant impact. Prior to implementation, a risk and optimization study led to placement of a vertical sheet‐pile wall around the treatment zone to minimize groundwater flow, and a pilot test of a novel direct‐drive method for installation of the heater casings. Because of a shallow water table, a layer of clean fill was placed over the treatment zone, and partial dewatering was necessary prior to heating. A network of vertical multiphase extraction wells and horizontal vapor extraction wells was used to establish hydraulic and pneumatic control and to capture the contaminants. The site was split into four decision units, each with a rigorous soil sampling program which included collecting a total of 270 confirmatory soil samples from locations with the highest pretreatment CVOC concentrations requiring reduction to below 1 mg/kg for each contaminant. Temperature monitoring and mass removal trends were used to trigger the sampling events. Eventually, a small area near the center of the site required the installation of four additional heaters before the soil goals were reached after 238 days of heating. The total energy usage for heating and treating the source area was 23 million kWh—slightly lower than the estimated 26.5 million kWh. Actual energy losses and the energy removal associated with the extracted steam were lower than anticipated. An estimated 13,400 kg (29,800 lbs) of CVOC mass was removed, and all soil goals were met. This paper presents the challenges associated with a project of this scale and describes the solutions to successfully complete the ISTD remedy.  相似文献   

3.
ZVI‐Clay is an emerging remediation approach that combines zero‐valent iron (ZVI)‐mediated degradation and in situ stabilization of chlorinated solvents. Through use of in situ soil mixing to deliver reagents, reagent‐contaminant contact issues associated with natural subsurface heterogeneity are overcome. This article describes implementation, treatment performance, and reaction kinetics during the first year after application of the ZVI‐Clay remediation approach at Marine Corps Base Camp Lejeune, North Carolina. Primary contaminants included trichloroethylene, 1,1,2,2‐tetrachloroethane, and related natural degradation products. For the field application, 22,900 m3 of soils were treated to an average depth of 7.6 m with 2% ZVI and 3% sodium bentonite (dry weight basis). Performance monitoring included analysis of soil and water samples. After 1 year, total concentrations of chlorinated volatile organic compounds (CVOCs) in soil samples were decreased by site‐wide average and median values of 97% and >99%, respectively. Total CVOC concentrations in groundwater were reduced by average and median values of 81% and >99%, respectively. In several of the soil and groundwater monitoring locations, reductions in total CVOC concentrations of greater than 99.9% were apparent. Further reduction in concentrations of chlorinated solvents is expected with time. Pre‐ and post‐mixing average hydraulic conductivity values were 1.7 × 10?5 and 5.2 × 10?8 m/s, respectively, indicating a reduction of about 2.5 orders of magnitude. By achieving simultaneous contaminant mass depletion and hydraulic conductivity reduction, contaminant flux reductions of several orders of magnitude are predicted.  相似文献   

4.
The Effect of Three Drilling Fluids on Ground Water Sample Chemistry   总被引:1,自引:0,他引:1  
Three monitoring wells were installed in borings that were constructed using water-based drilling fluids containing either (1) guar bean, (2) guar bean with breakdown additive, or (3) bentonite. These fluids were selected to observe their effect on the chemistry of subsequent water samples collected from the wells. The wells were installed to depths of 66 feet, 100.5 feet and 103 feet, respectively, in fine-to-medium sand and gravel outwash deposits near Antigo, Wisconsin. Drilling fluids were necessary to maintain an open borehole during well construction through strata containing cobbles and boulders.
The bentonite and guar drilling fluids caused temporarily elevated concentrations of chemical oxygen demand (COD) in ground water samples collected from the monitoring wells. Using standard development, purging and sampling procedures, elevated COD concentrations persisted for about 50 days for the well bored with the guar-with-additive fluid, 140 days for the bentonite well and 320 days for the guar well. Unfiltered ground water samples for all wells had greater concentrations of COD than samples filtered through a 0.45 micron filter. Sulfate concentrations also decreased with time in the guar-with-additive well and bentonite well, but not in the guar well.
The elevated COD concentrations are attributed to the large concentrations of oxidizable carbon present in the guar bean drilling fluid and in the organic polymers present in the bentonite drilling fluid. Well development and purging procedures, including borehole flushing, surging, bailing and/or chemically induced viscosity breakdown of the guar mud decreased the time before background conditions were achieved. Future research should evaluate the physical and geochemical interaction of different drilling fluid compositions with a variety of geologic matrices and drilling, well development and well purging techniques.  相似文献   

5.
The screened auger is a laser-slotted, hollow-stem auger through which a representative sample of ground water is pumped from an aquifer and tested for water-quality parameters by appropriate field-screening methods. Screened auger sampling can be applied to ground water quality remedial investigations, providing:(1) a mechanism for determining a monitoring well's optimal screen placement in a contaminant plume; and (2) data to define the three-dimensional configuration of the contaminant plume.
Screened auger sampling has provided an efficient method for investigating hexavalent chromium and volatile organic compound contamination in two sandy aquifers in Cadillac, Michigan. The aquifers approach 200 feet in thickness and more than 1 square mile in area. A series of screened auger borings and monitoring wells was installed, and ground water was collected at 10-foot intervals as the boreholes were advanced to define the horizontal and vertical distribution of the contaminant plumes. The ability of the screened auger to obtain representative ground water samples was supported by the statistical comparison of field screening results and subsequent laboratory analysis of ground water from installed monitoring wells.  相似文献   

6.
This study evaluates the efficiency of a full‐scale, 81 m‐wide permeable reactive barrier (PRB) configured by injection of dairy whey in the downgradient region of a contaminant source zone to enhance the in situ biodegradation of high concentrations (102 to 103μg/L) of chlorinated ethenes (CEs). Ten biannual whey injections were completed in a 3.5‐year pilot phase and 1.5‐year operational phase. Improved and sustained dechlorination was observed at extraction/injection and downgradient wells in the fully‐operational phase, when dried whey masses were increased from 13.6 kg to 230–360 kg, whey slurry volumes were increased from 2300 L to 307,000–480,000 L, and extraction/injection well loops were employed for the application of whey. At extraction/injection wells, CEs decreased to low (≤10 μg/L) or undetectable levels. At downgradient wells, average trichloroethene concentrations decreased, by as much as 100% (from ≤384.2 during the pilot phase to ≤102.6 μg/L during the operational phase), while average cis‐dichloroethene concentrations decreased by as much as 57.5% (from ≤6466.1 to ≤4912.2 μg/L). Downgradient vinyl chloride averages either increased by as much as 63.8% (from ≤859.6 to ≤1407.9 μg/L) or decreased by 64.0% (from 1375.4 to 880 μg/L). Downgradient ethene + ethane averages increased by as much as 73.2% (from ≤1145.3 to ≤1347.1 μg/L). On the basis of the 2008 average market price, the estimated material cost of whey is $1.96/kg organic carbon or, for the configuration of an 81 m PRB by biannual application of 300 kg whey, $325/year. Carbon substrate cost comparisons and implications for efficient in situ treatment design are discussed.  相似文献   

7.
A direct-drive high-resolution passive profiler (HRPP) was developed to quantify and delineate concentrations of chlorinated volatile organic compounds (CVOCs), geochemical indicators and CVOC-degrading microorganisms/genes, as well as to perform compound-specific stable isotope analysis (CSIA) of CVOCs and estimate interstitial velocity at <30-cm resolution. The profilers can be coupled together to provide a continuous sample interval and advanced to depths up to approximately 9 m below-ground surface (bgs) within saturated media where direct-push techniques are feasible. The HRPP was field tested in a previous dense nonaqueous phase liquid (DNAPL) source zone at the former Naval Air Station in Alameda, CA. HRPP data sets were compared to the following traditional groundwater data sets: CVOC and anion concentrations in standard and multilevel monitoring well water samples, CVOC concentrations in soil core samples, qualitative contaminant profiles delineated with a membrane interface probe (MIP), microbial community and CSIA profiles from Bio-Traps® deployed in wells, groundwater velocity from passive flux meters (PFMs), lithologic profiles correlated with MIP electrical conductivity (EC), and velocity estimates based on permeability profiles measured with a Geoprobe hydraulic profiling tool (HPT). In some cases, the HRPP data were equivalent to traditional techniques and, in other cases, the HRPP data were more representative of local variability rather than bulk aquifer conditions. Overall the results support the use of the HRPP to provide high-resolution data on concentrations, velocity, and microbial activity in temporary direct-push deployments without well installation, providing a new tool to better assess source zones and contaminated groundwater plumes, even in low permeability media, and to increase the fidelity of site transport models.  相似文献   

8.
The city of St. Petersburg is testing subsurface injection of treated sewage into the Floridan aquifer as a means of eliminating discharge of sewage to surface waters and as a means of storing treated sewage for future nonpotable reuse. The injection zone at the test site at the start of injection contained saline water with chloride concentrations ranging from 14,000 to 20,000 milligrams per liter (mg/1). Treated sewage with a mean chloride concentration of 170 mg/1 was injected through a single well for 12 months at a mean rate of 4.7 × 105 cubic feet per day. The volume of water injected during the year was 1.7 × 108 cubic feet. Dissolved oxygen was contained in the sewage prior to injection. Water removed from the injection zone during injection was essentially free of oxygen. Probable growth of denitrifying bacteria and, thus, microbial denitri-fication, was suggested by bacterial counts in water from two observation wells that were close to the injection well. The volume fraction of treated sewage in water from wells located 35 feet and 733 feet from the injection well and open to the upper part of the injection zone stabilized at about 0.9 and 0.75, respectively. Chloride concentrations stabilized at about 1,900 mg/1 in water from the well that was 35 feet from the injection well and stabilized at about 4,000 mg/1 in water from the well that was 733 feet from the injection well. These and other data suggest that very little near injection-quality treated sewage would be recoverable from storage in the injection zone.  相似文献   

9.
A critical analysis of in situ chemical oxidation (ISCO) projects was performed to characterize situations in which ISCO is being implemented, how design and operating parameters are typically employed, and to determine the performance results being achieved. This research involved design of a database, acquisition and review of ISCO project information, population of the database, and analyses of the database using statistical methods. Based on 242 ISCO projects included in the database, ISCO has been used to treat a variety of contaminants; however, chlorinated solvents are by far the most common. ISCO has been implemented at sites with varied subsurface conditions with vertical injection wells and direct push probes being the most common delivery methods. ISCO has met and maintained concentrations below maximum contaminant levels (MCLs), although not at any sites where dense nonaqueous phase liquids (DNAPL) were presumed to be present. Alternative cleanup levels and mass reduction goals have also been attempted, and these less stringent goals are met with greater frequency than MCLs. The use of pilot testing is beneficial in heterogeneous geologic media, but not so in homogeneous media. ISCO projects cost $220,000 on average, and cost on average $94/yd3 of target treatment zone. ISCO costs vary widely based on the size of the treatment zone, the presence of DNAPL, and the oxidant delivery method. No case studies were encountered in which ISCO resulted in permanent reductions to microbial populations or sustained increases in metal concentrations in groundwater at the ISCO-treated site.  相似文献   

10.
A pool of dense nonaqueous phase liquid (DNAPI.) containing TCE and other chlorinated solvents has been removed from the subsurface at Hill Air Force Base, Uthah. as part of an interim remedial action. The removal of the DNAPI. pool means that future off-site migration of dissolved contaminants in the ground water is minimized, and costs for final remedial actions are reduced. A pump-and-treat system recovered more than 23.000) gallons of DNAPI. and one million gallons of contaminated ground water from the aquifer. The efficiency of this remedial action was evaluated on the basis of extensive field and laboratory data. The behavior of DNAPI. flow in the aquifer sands was characterized by collecting core samples from two borings in the DNAPL pool and measuring relative permeabilities and DMAPI. saturation. Core Hooding results show that approximately one-third of the DNAPI. originally in the pool is not recovered by water displacement, but remains as a residual saturation held in place by capillary pressure. However, subsequent Hooding with two pore volumes of surfactant solution reduced the residual DNAPI. saturation in the sand by one order of magnitude. Analytical and numerical models for the DNAPI flow behavior at the site were developed. This is the first time that such models have been developed and applied to an actual DNAPI. pumping lest conducted in the field. Because measured permeabilities and residual saturations were used lo calibrate the models. the model predictions could be used lo provide valuable insights into the controlling mechanisms for DNAPL recovery. The data collection and modeling procedures outlined in this paper can be used lo enhance the efficiency and minimize the cost 10 clean up this and other DNAPI.-contaminated sites.  相似文献   

11.
A new in‐situ remediation concept termed a Horizontal Reactive Media Treatment Well (HRX Well®) is presented that utilizes horizontal wells filled with reactive media to passively treat contaminated groundwater in‐situ. The approach involves the use of large‐diameter directionally drilled horizontal wells filled with granular reactive media generally installed parallel to the direction of groundwater flow. The design leverages natural “flow‐focusing” behavior induced by the high in‐well hydraulic conductivity of the reactive media relative to the aquifer hydraulic conductivity to passively capture and treat proportionally large volumes of groundwater within the well. Clean groundwater then exits the horizontal well along its downgradient sections. Many different types of solid granular reactive media are already available (e.g., zero valent iron, activated carbon, ion exchange resins, zeolite, apatite, chitin); therefore, this concept could be used to address a wide range of contaminants. Three‐dimensional flow and transport simulations were completed to assess the general hydraulic performance, capture zones, residence times, effects of aquifer heterogeneity, and treatment effectiveness of the concept. The results demonstrate that capture and treatment widths of up to tens of feet can be achieved for many aquifer settings, and that reductions in downgradient concentrations and contaminant mass flux are nearly immediate. For a representative example, the predicted treatment zone width for the HRX Well is approximately 27 to 44 feet, and contaminant concentrations immediately downgradient of the HRX Well decreased an order of magnitude within 10 days. A series of laboratory‐scale physical tests (i.e., tank tests) were completed that further demonstrate the concept and confirm model prediction performance. For example, the breakthrough time, peak concentration and total mass recovery of methylene blue (reactive tracer) was about 2, 35, and 20 times (respectively) less than chloride (conservative tracer) at the outlet of the tank‐scale HRX Well.  相似文献   

12.
The horizontal reactive media treatment well (HRX Well®) uses directionally drilled horizontal wells filled with a treatment media to induce flow-focusing behavior created by the well-to-aquifer permeability contrast to passively capture proportionally large volumes of groundwater. Groundwater is treated in situ as it flows through the HRX Well and downgradient portions of the aquifer are cleaned via elution as these zones are flushed with clean water discharging from the HRX Well. The HRX Well concept is particularly well suited for sites where long-term mass discharge control is a primary performance objective. This concept is appropriate for recalcitrant and difficult-to-treat constituents, including chlorinated solvents, per- and polyfluoroalkyl substances (PFAS), 1,4-dioxane, and metals. A full-scale HRX Well was installed and operated to treat trichloroethene (TCE) with zero valent iron (ZVI). The model-predicted enhanced flow through the HRX Well (compared to the flow in and equivalent cross-sectional area orthogonal to flow in the natural formation before HRX Well installation) and treatment zone width was consistent with flows and widths estimated independently by point velocity probe (PVP) testing, HRX Well tracer testing, and observed treatment in downgradient monitoring wells. The actual average capture zone width was estimated to be between 45 and 69 feet. Total TCE mass discharge reduction was maintained through the duration of the performance monitoring period and exceeded 99.99% (%). Decreases in TCE concentrations were observed at all four downgradient monitoring wells within the treatment zone (ranging from 50 to 74% at day 436), and the first arrival of treated water was consistent with model predictions. The field demonstration confirmed the HRX Well technology is best suited for long-term mass discharge control, can be installed under active infrastructure, requires limited ongoing operation and maintenance, and has low life cycle energy and water requirements.  相似文献   

13.
When designing in situ soil vapor extraction systems, the number and placement of vapor extraction wells arc typically based on the radius of influence determined from some combination of pilot test data, theoretical considerations, and experience. In this report, we examine common methods used to determine the radius of influence, and through examples we illustrate how effective this remedial design approach is. Significant conclusions arc the following: (a) systems designed by radius of influence-based approaches may never achieve desired remedial goals: (b) systems designed by radius of influence-based approaches may result in longer operation times and higher total costs than a system that incorporates remedial goals and some level of fundamentally based predictive modeling: and (c) at best, the radius of influence-based approach ensures containment of contaminant vapors.  相似文献   

14.
Groundwater beneath the former Nebraska Ordnance Plant (NOP) is contaminated with the explosive hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). The current pump and treat facility is preventing offsite migration but does not offer a short-term solution. Our objective was to quantify the effectiveness of permanganate to degrade RDX in situ. This was accomplished by performing laboratory treatability experiments, aquifer characterization, and a pilot-scale in situ chemical oxidation (ISCO) demonstration. Treatability experiments confirmed that permanganate could mineralize RDX in the presence of NOP aquifer solids. The pilot-scale ISCO demonstration was performed using an extraction-injection well configuration to create a curtain of permanganate between two injection wells. RDX destruction was then quantified as the RDX-permanganate plume migrated downgradient through a monitoring well field. Electrical resistivity imaging (ERI) was used to identify the subsurface distribution of permanganate after injection. Results showed that RDX concentrations temporally decreased in wells closest to the injection wells by 70% to 80%. Observed degradation rates (0.12 and 0.087/d) were lower than those observed under laboratory batch conditions at 11.5 °C (0.20/d) and resulted from lower than projected permanganate concentrations. Both ERI and spatial electrical conductivity measurements verified that permanganate distribution was not uniform throughout the 6.1-m (20 feet) well screens and that groundwater sampling captured both treated and nontreated groundwater during pumping. Although heterogeneous flow paths precluded a uniform permanganate distribution, pilot-scale results provided proof-of-concept that permanganate can degrade RDX in situ and support permanganate as a possible remedial treatment for RDX-contaminated groundwater.  相似文献   

15.
Volatile organic compounds delected in ground water from wells at Test Area North (TAN) at the Idaho National Engineering Laboratory (INEL) prompted RCRA facility investigations in 1989 and 1990 and a CERCLA-driven RI/FS in 1992. In order to address ground water treatment feasibility, one of the main objectives, of the 1992 remedial investigation was to determine the vertical extent of ground water contamination, where the principle contaminant, of concern is trichloroethylene (TCE). It was hypothesized that a sedimentary interbed at depth in the fractured basalt aquifer could be inhibiting vertical migration of contaminants to lower aquifers. Due to the high cost of drilling and installation of ground water monitoring wells at this facility (greater than $100,000 per well), a real time method was proposed for obtaining and analyzing ground water samples during drilling to allow accurate placement of well screens in zones of predicted VOC contamination. This method utilized an inflatable pump packer pressure transducer system interfaced with a datalogger and PC at land surface. This arrangement allowed for real lime monitoring of hydraulic head above and below the packer to detect leakage around the packer during pumping and enabled collection of head data during pumping for estimating hydrologic properties. Analytical results were obtained in about an hour from an on-site mobile laboratory equipped with a gas chromalograplvmass spectrometer (GC/MS). With the hydrologic and analytical results in hand, a decision was made to either complete the well or continue drilling to the next test zone. In almost every case, analytical results of ground water samples taken from the newly installed wells closely replicated the water quality of ground water samples obtained through the pump packer system.  相似文献   

16.
The impact of lost circulation during rotary drilling near an existing monitoring well cluster was evaluated by periodic measurements of water levels and contaminant concentrations at the well cluster. Due to regulatory concerns, changes in water levels or VOC concentration in the well cluster during drilling would trigger monitoring well redevelopment. The borehole was drilled approximately 30 feet northeast of four nested monitoring wells that screen Devonian and Silurian carbonate bedrock at depths of 15, 60, 130, and 190 feet. Following complete circulation loss at depths of 177 and 1 S3 feet in the borehole, a rapid decrease in water levels was observed in the upper three monitoring wells. The water level in the well that was screened through the lost circulation zones increased slightly.
Decreasing water levels in formations located above the point of circulation loss appear to occur in response to a sudden decrease in borehole fluid pressure caused by the flow of drilling fluid into the formation. The relative contribution of contaminated formation water lo the borehole can be estimated by using the time-drawdown relationship and estimates of transmissivity. At the point of circulation loss, significant dilution of contaminant concentrations occurs from the loss of drilling fluid into the contaminated zone. Contaminated formation water entering the borehole during periods of complete lost circulation may mobilize contaminants from upper lo lower formations. Lost circulation into a formation would be signaled by a water level increase in monitoring wells. The wells would subsequently require development to remove the volume of fluid lost to the formation, including both drilling fluid and contaminated formation water. Monitoring wells exhibiting declining water levels following lost circulation would not require development since drilling water has not entered the zones screened by these wells.  相似文献   

17.
Permeable reactive barriers (PRBs), such as mulch biowalls, have been installed at numerous groundwater cleanup sites, and laboratory and field studies have demonstrated biotic and abiotic processes that degrade chlorinated volatile organic compounds (CVOCs) in groundwater passing through these engineered remedies. However, the longevity of mulch biowalls remains a fundamental research question. Soil and groundwater sampling at seven mulch biowalls at Altus Air Force Base (AFB) approximately 10 years after installation demonstrated the ongoing degradation of CVOCs. Trichloroethene was not detected in five of seven groundwater samples collected from the biowall despite upgradient detections above federal drinking water standards. Microbial sampling established the presence of key dechlorinating bacteria and the abundance of genes encoding specific enzymes for degradation, high methane concentrations, low sulfate concentrations, and negative oxidation-reduction potential, all indicative of highly reducing conditions within the biowalls and favorable conditions for CVOC destruction via microbial reductive dechlorination. High cellulose content (>79%) of the mulch, elevated total organic carbon (TOC) content in groundwater, and elevated potentially bioavailable organic carbon (PBOC) measurements in soil samples further supports an ongoing, long-lived source of carbon. These results demonstrate the ongoing and long-term efficacy of the mulch biowalls at Altus AFB. In addition, concentrations of bacteria, TOC, PBOC, and other geochemical parameters suggest a modest impact of the biowalls downgradient. The continued presence of CVOCs downgradient may be attributable to back diffusion from low-permeability shale. However, the biowalls continue to provide benefits by removing CVOCs in groundwater, thus reducing further CVOC loading to the downgradient, low-permeability strata.  相似文献   

18.
Selection of monitored natural attenuation as a ground water remedy requires that sound scientific documentation clearly illustrating the effectiveness of this remedial alternative be presented to regulatory agencies and concerned citizens. An innovative radial diagram approach is applied to illustrate natural attenuation trends for total benzene, toluene, ethylbenzene, and xylenes (BTEX) and chlorinated ethenes at a former fire training area at Pittsburgh Air Force Base, New York. A BTEX-CAH (chlorinated aliphatic hydrocarbons) radial diagram map shows that concentrations of site contaminants are generally decreasing along the primary flowpath downgradient from the source area. This radial diagram map also suggests that there is a spatial correlation between decreasing CAH parent compound concentrations and increasing or stable daughter product concentrations. This provides secondary evidence of intrinsic biodegradation of TCE downgradient from the source area. A SEQUENCE-Redox™ map suggests that there is a spatial correlation between trends in electron acceptor and metabolic byproduct concentrations, and the decline in total BTEX concentrations downgradient from the source area. This correlation provides secondary evidence for the intrinsic biodegradation of total BTEX in the aquifer. This study demonstrates that radial diagram visual aids can provide a clear and efficient approach for documenting natural attenuation lines of evidence, as an alternative or a complement to using multiple contour maps, tabulated data, or log-linear plots.  相似文献   

19.
Perchlorate was detected in a municipal wellfield in Evart, Michigan in April 2015. Perchlorate concentrations were detected initially in six of the City's wells at concentrations ranging up to 20 μg/L. An investigation to identify the source determined that the perchlorate was from fireworks launched during the annual 4th of July show held at the fairgrounds located upgradient from the wellfield. The use of approximately 600 kg of fireworks during the annual display resulted in an annual loading of approximately 4 kg of perchlorate to groundwater. An aggressive groundwater extraction system began operation in June 2016 to restore water quality in the affected aquifer, and the 2016 fireworks display was relocated to a location outside the capture zone of the water supply wells. Within 18 months average perchlorate concentrations in the water supply wells had been reduced to about 0.6 μg/L. The extraction system continued to operate through the end of 2019, by which time the average perchlorate concentrations in the water supply wells were reduced to 0.2 μg/L. In 2019, approximately 0.4 kg of perchlorate were removed from the aquifer, about one-half of the amount removed in 2018, reflecting the slow leaching of perchlorate of fireworks residuals from vadose zone soils.  相似文献   

20.
The city of St. Petersburg has been testing subsurface injection of treated sewage into the Floridan aquifer as a means of eliminating discharge of sewage to surface waters and as a means of storing treated sewage for future non-potable reuse. The injection zone originally contained native saline ground water that was similar in composition to sea water. The zone has a transmissivity of about 1.2 X 106 feet squared per day (ft2/d) and is within the lower part of the Floridan aquifer. Treated sewage that had a mean chloride concentration of 170 milligrams per liter (mg/1) was injected through a single well for 12 months at a mean rate of 4.7 X 105 cubic feet per day (ft3/d). The volume of water injected during the year was 1.7 X 108 cubic feet. Pressure buildup at the end of one year ranged from less than 0.1 to as much as 2.4 pounds per square inch (lb/in2) in observation wells at the site. Pressure buildup in wells open to the upper part of the injection zone was related to buoyant lift acting on the mixed water in the injection zone in addition to subsurface injection through the injection well. Calculations of the vertical component of pore velocity in the semiconfining bed underlying the shallowest permeable zone of the Floridan aquifer indicate upward movement of native water. This is consistent with the 200- to 600-mg/l increase in chloride concentration observed in water from the shallowest permeable zone during the test.  相似文献   