首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
At present, methods based on allowable displacements are frequently used in the seismic design of earth retaining structures. However, these procedures ignore both the foundation soil deformability and the seismic amplification of the soil placed behind the retaining wall. Thus, they are not able to predict neither a rotational failure mechanism nor seismic induced lateral displacements with an acceptable degree of accuracy for the most general case. In this paper, a series of 2D finite-element analyses were carried out to study the seismic behavior of gravity retaining walls on normally consolidated granular soils. Chilean strong-motion records were applied at the bedrock level. An advanced non-linear constitutive model was used to represent both the backfill and foundation soil behavior. This elastoplastic model takes into account both the stress dependency of soil stiffness and coupling between shear and volumetric strains. In unloading–reloading cycles, the non-linear shear-modulus reduction with shear strain amplitude is considered. Interface elements were used to model soil–structure interaction. Routine-design charts were derived from the numerical analyses to predict the lateral movements at the base and top of gravity retaining walls located at sites with similar seismic characteristics to the Chilean subduction zone. Thus, wall seismic rotation can also be obtained. The developed charts consider wall dimensions, granular soil properties, bedrock depth, and seismic input motion characteristics. As shown, the proposed charts match well with available experimental data.  相似文献   

2.
The earthquake response of cantilever retaining walls is explored by means of theoretical analyses and shaking table testing conducted at University of Bristol (EERC - EQUALS). The theoretical investigations employ both limit analysis and wave-propagation methods, which take into account different aspects of the problem such as inertia, strength, kinematics and compatibility of deformations. The experimental programme encompasses different combinations of retaining wall geometries, soil configurations and input ground motions. The response analysis of the systems at hand aims at shedding light onto salient features of the problem, such as: (1) the magnitude of soil thrust and its point of application; (2) the relative sliding versus rocking of the wall base and the corresponding failure modes; (3) the importance of the interplay between soil stiffness, wall dimensions and excitation characteristics, as affecting the above; (4) the importance of wall dynamics and phase differences between peak stresses and displacements. The results of the experimental investigations are in good agreement with the theoretical models and provide a better understanding on the complex mechanics of the problem.  相似文献   

3.
The results of an experimental study conducted on two 1:2 reduced-scale geotextile-reinforced soil retaining walls are presented and discussed. El Centro earthquake and sinusoidal harmonic motion excitations were applied to the 1.9 m tall models. The design parameter investigated was the reinforcement length (L/H = 0.9 in the 1st model and L/H = 0.6 in the 2nd model). The results were analyzed to evaluate the acceleration amplification, strains in the reinforcement layers and facing wall deformation. The test results showed that in both experiments the walls were in fact designed to behave rigidly and almost no residual displacements were observed on the front of the wall. The most important conclusion drawn from the experimental work was that Geosynthetic Reinforced Retaining Structures designed according to the current specifications behave very successfully under earthquake loading conditions.  相似文献   

4.
An overview of past and recent developments on the subject of seismic earth pressures on yielding, gravity-type walls, retaining cohesionless backfill, is first presented, focusing on available data on the issue of phase difference that develops between the peak values of wall inertia and seismic earth thrust increment. The results of a FEM parametric study are next presented regarding the dependence on the resulting dynamic earth thrust reduction – acting on the time of peak wall inertia – on backfill rigidity, wall height, and shaking characteristics. The reliability of the numerical analyses was verified by modeling centrifuge tests reported by Nakamura [24] and successfully comparing measured vs. computed behavior. The results of the parametric analyses indicate that the seismic active earth thrust, acting on the wall at the time of maximum wall inertia, is significantly reduced (compared to its peak value) with increasing shaking intensity of backfill, increasing wall displacements, increasing wall height, and decreasing backfill rigidity. No systematic dependence on the ratio of input motion frequency to the natural frequency of the backfill (f/f1) was observed. The above findings: (1) verify earlier experimental and numerical results, (2) explain the reported lack of damage to retaining walls under strong ground shaking, and (3) indicate the need for revising the pertinent provisions of current seismic codes. Graphs summarizing the results of the numerical analyses are presented which may be used as a guide for selecting the magnitude of seismic active earth thrust that needs to be taken into account in the design of the examined type of earth retaining walls.  相似文献   

5.
韩鹏飞  隋孝民 《地震工程学报》2015,37(2):585-593,611
介绍基于性能抗震设计的核心理念,以支挡结构震害调查分析为背景,阐述开展高烈度区重力式挡墙基于性能抗震设计研究的必要性;构建重力式挡墙基于性能的抗震设计框架,归类分析现行规范与基于性能抗震设计的关键技术问题;依据支挡结构震害调查及大型振动台模型试验,提出位移指数可作为衡量挡墙抗震性能的量化指标,确定重力式挡墙基于性能抗震设计的性能准则及流程;经对比计算基于性能与规范抗震设计的挡墙算例,显示基于性能抗震设计的优越性,为高烈度区重力式挡墙基于性能抗震设计的工程应用提出建议。  相似文献   

6.
In this paper the stability of a tied-back wall subjected to seismic loads is analysed for a predetermined mode of failure (rotation about the top of the wall) and the analysis is compared with data from tests on this type of wall using the seismic simulator at the State University of New York at Buffalo. We carried out a pseudo-static analysis of the problem using the Mononobe-Okabe earth pressure coefficients, wherein the dynamic effects due to the seismic loading are converted into equivalent static loads. The acceleration ratio at which the wall fails by rotation about the top was obtained by considering the moments due to the various lateral earth pressure resultants and the inertial forces induced in the soil due to the seismic loading. We found that the presence of wall friction on the passive side significantly enhances the stability of the flexible retaining wall under seismic loads. Thus, flexible retaining walls supporting dry cohesionless soil can be very efficient during earthquakes. Under moderate earthquakes, an increase in the depth of embedment increases the dynamic factor of safety significantly. However, beyond a certain acceleration ratio for a soil with a particular value of ø, any increase in the depth of emdedment has no effect in impeding failure, irrespective of any change in the geometry of the system. Seismic design charts are presented to evaluate the stability of, and to design, flexible retaining walls embedded in dry cohesionless soils under seismic loading.  相似文献   

7.
Reinforced-soil retaining structures possess inherent flexibility, and are believed to be insensitive to earthquake shaking. In fact, several such structures have successfully survived destructive earthquakes (Northridge 1994, Kobe 1995, Kocaeli 1999, and Chi-Chi 1999). This paper investigates experimentally and theoretically the seismic performance of a typical bar-mat retaining wall. First, a series of reduced-scale shaking table tests are conducted, using a variety of seismic excitations (real records and artificial multi-cycle motions). Then, the problem is analyzed numerically employing the finite element method. A modified kinematic hardening constitutive model is developed and encoded in ABAQUS through a user-defined subroutine. After calibrating the model parameters through laboratory element testing, the retaining walls are analyzed at model scale, assuming model parameters appropriate for very small confining pressures. After validating the numerical analysis through comparisons with shaking table test results, the problem is re-analyzed at prototype scale assuming model parameters for standard confining pressures. The results of shaking table testing are thus indirectly “converted” (extrapolated) to real scale. It is shown that: (a) for medium intensity motions (typical of Ms≈6 earthquakes) the response is “quasi-elastic”, and the permanent lateral displacement in reality could not exceed a few centimeters; (b) for larger intensity motions (typical of Ms≈6.5–7 earthquakes) bearing the effects of forward rupture directivity or having a large number of strong motion cycles, plastic deformation accumulates and the permanent displacement is of the order of 10–15 cm (at prototype scale); and (c) a large number of strong motion cycles (N>30) of unrealistically large amplitude (A=1.0 g) is required to activate a failure wedge behind the region of reinforced soil. Overall, the performance of the bar-mat reinforced-soil walls investigated in this paper is totally acceptable for realistic levels of seismic excitation.  相似文献   

8.
水平地震作用沿墙高的分布、弱粘性土地震土压力、和挡墙体系考虑水的作用是挡土墙抗震研究中的三个重要问题。首先对其研究进展进行了简要总结。然后针对近年来大量涌现的新型、异型、轻型挡土墙的抗震研究现状进行了评述,包括现场地震调查、振动台及离心机试验、悬臂L型挡土墙、锚杆式及土钉式挡土墙、加筋土挡土墙和地下室挡墙。最后,指出了存在的问题和提出今后的研究方向。  相似文献   

9.
The effects of earthquakes on cantilever retaining walls with liquefiable backfills were studied. The experimental techniques utilized in this study are discussed here. A series of centrifuge tests was conducted on aluminum, fixed-base, cantilever wall models retaining saturated, cohesionless backfills. Accelerations on the walls and in the backfill, static and excess pore pressures in the soil, and deflections and bending strains in the wall were measured. In addition, direct measurements of static and dynamic lateral earth pressures were made. In some tests, sand backfills were saturated with the substitute pore fluid metolose. Modeling of model type experiments were conducted. The experimental measurements were found internally consistent and repeatable. Both static and dynamic earth pressure measurements were determined to be reliable. It was also observed that for the test configuration adopted, a special boundary treatment such as the use of duxseal is optional. Static and seismic modeling of models were also successful, which indicated that the assumed scaling relations were essentially correct.  相似文献   

10.
为了研究轻量土的主动土压力特性,通过开展大比尺刚性挡土墙模型试验,采用人工控制挡土墙位移的方式,分析轻量土作为墙后填土时的主动土压力分布规律。结果表明:轻量土的侧向土压力随着挡墙位移量的增加先降低后逐渐趋于稳定,侧向土压力在挡墙位移量为3 mm时初步达到稳定状态,对比发现轻量土的主动土压力显著小于重塑黄土,这表明轻量土可以有效降低墙背主动土压力。轻量土的主动土压力系数处于0~0.16之间,沿着挡墙分布较为稳定,而重塑黄土主动土压力系数介于0~0.57之间,显著大于轻量土的主动土压力系数。经朗肯理论值与模型试验值对比分析,发现轻量土的朗肯主动土压力小于试验值,理论值与试验值之间的绝对误差处于0~6.32 kPa之间,其在实际工程中可以忽略不计。鉴于模型试验中墙背与填土之间存在一定的摩擦,朗肯理论在计算轻量土的主动土压力时仍较为准确。通过模型试验研究和传统理论分析,揭示了轻量土的主动土压力特性,对于完善轻量土土压力理论具有重要意义。  相似文献   

11.
Knowledge of seismic active earth pressure behind rigid retaining wall is very important. Commonly used Mononobe–Okabe method considers pseudo-static approach, which gives the linear distribution of seismic earth force. In this paper, the pseudo-dynamic approach, which considers the effect of primary and shear wave propagations, is adopted to calculate the seismic active force. Considering the planar rupture surface, the effect of wide range of parameters like inclination of retaining wall, inclination of backfill surface, wall friction and soil friction angle, shear wave and primary wave velocity, horizontal and vertical seismic coefficients are taken into account to evaluate the seismic active force. Results are presented in terms of seismic coefficients in tabular form and variation of pressure along the depth.  相似文献   

12.
Seismic active pressure distribution history behind rigid retaining walls   总被引:1,自引:0,他引:1  
Evaluating the seismic active earth pressure on retaining walls is currently based on pseudo-static method in practices. In this method, however, it is not simple, choosing an appropriate value for earthquake coefficient, which should fully reflect the dynamic characteristics of both soil and loading is an important problem. On the other hand, by using only two extra dynamic parameters that are shear wave velocity of soil and predominant frequency of probable earthquake, one can benefit from another more accurate tool called pseudo-dynamic method to solve the problem of earth pressure.In this study in the framework of limit equilibrium analysis, pseudo-dynamic method has been applied into horizontal slice method of analysis to account for the effect of earthquake on lateral earth pressure history behind rigid retaining walls. The pressure history resulted from a number of analyses shows that before and after reaching the peak resultant force, different pressure distributions occur behind a wall that put more local pressure than the same at peak. This method would be a tool to control this phenomenon in wall design.  相似文献   

13.
We present a mathematical model of local, steady groundwater flow near a vertical barrier wall. Flow features represented in the model include an impermeable arc-shaped barrier wall and multiple wells; distant boundary conditions are not included explicitly, but their effects on the local flow field are modelled by specifying a uniform flow at infinity and a constant areal recharge within a local domain. We develop an explicit closed-form solution to the boundary-value problem using the analytic element method. The solution is an extension of a harmonic solution presented by Anderson and Mesa [Anderson EI, Mesa E. The effects of vertical barrier walls on the hydraulic control of contaminated groundwater. Adv Water Resourc 2006;29(1):89–98] which does not include the effects of recharge. We demonstrate that the general solution with recharge consists of the harmonic solution superposed on a special case of the harmonic solution along with two elementary one-dimensional flow solutions. The results are used to investigate the effects of areal recharge on the capture zone envelopes of the pumping wells and on the reduction in discharge that can be achieved by including a barrier wall in a pump and treat design. We find that the benefits of including an open barrier wall in a design, measured as a reduction in the pumping rate required to contain a plume, increase for higher recharge rates. Dimensionless plots of capture zone envelopes are presented for a practical well and barrier wall configuration.  相似文献   

14.
Observations from recent earthquakes show that retaining structures with non-liquefiable backfills perform extremely well; in fact, damage or failures related to seismic earth pressures are rare. The seismic response of a 6-m-high braced basement and a 6-m free-standing cantilever wall retaining a compacted low plasticity clay was studied in a series of centrifuge tests. The models were built at a 1/36 scale and instrumented with accelerometers, strain gages and pressure sensors to monitor their response. The experimental data show that the seismic earth pressure on walls increases linearly with the free-field PGA and that the earth pressures increase approximately linearly with depth, where the resultant acts near 0.33 H above the footing as opposed to 0.5–0.6 H, which is suggested by most current design methods. The current data suggest that traditional limit equilibrium methods yield overly conservative earth pressures in areas with ground accelerations up to 0.4g.  相似文献   

15.
Seismic stability analysis of gravity retaining walls   总被引:1,自引:0,他引:1  
A new approach based on the category of upper bound theorem of limit analysis is presented in this study to consider the seismic stability of gravity retaining walls. The retaining wall and the backfill soil were taken as a whole system. For a translational failure mechanism assumed, formulas are provided to calculate directly the yield acceleration and the inclination of the failure surface. An example is shown to illustrate the method. Comparisons are made with limit equilibrium method, and the results are found consistent. Based on a limited parametric study, it is shown that the wall roughness has remarkable influence on the yield acceleration.  相似文献   

16.
This work deals with the evaluation of the dynamic pressures and the associated forces on a pair of rigid vertical cantilever walls retaining a uniform, fully saturated poroelastic layer of soil. Hysteretic damping in the soil skeleton may also be present. Wall pressures and forces are induced by horizontal ground shaking harmonically varying with time and spatially invariant. The problem is solved analytically under conditions of plane strain. The governing partial differential equations of motion, after separation of variables and the simplifying assumptions of zero vertical normal stresses and zero horizontal variation of vertical displacements, reduce to a system of two ordinary differential equations for the amplitudes of the solid skeleton horizontal displacement and the pore water pressure, which are easily solved. The parameters examined include the ratio of the distance between walls to the height of the retained soil material and the soil material properties such as porosity, permeability and damping. The comprehensive numerical data presented indicate that the displacements, wall pressures and resultant forces are highly dependent on the distance between the walls for any values of porosity and permeability.  相似文献   

17.
The dynamic response of an elastic continuously nonhomogeneous soil layer over bedrock retained by a pair of rigid cantilever walls to a horizontal seismic motion and the associated seismic pressure acting on these walls are determined analytically–numerically. The soil non-homogeneity is described by a shear modulus increasing nonlinearly with depth. The problem is solved in the frequency domain under conditions of plane strain and its exact solution is obtained analytically. This is accomplished with the aid of Fourier series along the horizontal direction and solution of the resulting system of two ordinary differential equations with variable coefficients by the method of Frobenius in power series. Due to the complexity of the various analytical expressions, the final results are determined numerically. These results include seismic pressures, resultant horizontal forces and bending moments acting on the walls. The solution of the problem involving a single retaining wall can be obtained as a special case by assuming the distance between the two walls to be very large. Results are presented in terms of numerical values and graphs using suitable dimensionless quantities. The effect of soil non-homogeneity on the system response is assessed through comparisons for typical sets of the parameters involved.  相似文献   

18.
This technical note presents an analytical derivation of the expression for the total dynamic active thrust on a retaining wall from the c? soil backfill considering both horizontal and vertical seismic coefficients. The derivation is based on the Coulomb sliding wedge concept, and it considers tension cracks, wall adhesion, and surcharge in order to make the expression useful for practical applications. It is found that the special cases of the general expression result in the expressions for total static and dynamic active thrusts presented by earlier researchers for different field conditions of soil backfills with and without seismic loadings.  相似文献   

19.
A stress plasticity solution is proposed for evaluating the gravitational and dynamic active earth pressures on cantilever retaining walls with long heel. The solution takes into account the friction angle of the soil, wall roughness, backfill inclination and horizontal and vertical seismic accelerations. It is validated by means of the comparison with both traditional limit equilibrium methods (e.g. Mononobe–Okabe equations) and static and pseudostatic numerical FLAC analyses. For numerical analyses the soil is modelled as an elasto-plastic non-dilatant medium obeying the Mohr–Coulomb yield criterion, while the wall is elastic. The solutions for the horizontal and vertical seismic coefficients are proposed, which allow one to determine the intensity of the active thrust and its inclination δ with respect to the horizontal. It is demonstrated that the latter also depends on the soil friction angle φ. The inclination in seismic conditions δE is greater than the one in static conditions, δS, usually adopted in both cases. As a matter of fact, since wall stability conditions improve with the increase of inclination δ, the present method gives solutions that are less onerous than traditional ones, producing less conservative wall designs. Finally pseudostatic results are compared with proper dynamic analyses (by FLAC code) performed utilising four Italian accelerometric time-histories as input ground motion.  相似文献   

20.
In the design procedure for a retaining wall, the pseudo-static method has been widely used and dynamic earth pressure is calculated by the Mononobe–Okabe method, which is an extension of Coulomb’s earth pressure theory computed by force equilibrium. However, there is no clear empirical basis for treating the seismic force as a static force, and recent experimental research has shown that the Mononobe–Okabe method is quite conservative, and there exists a discrepancy between the assumed conditions and real seismic behavior during an earthquake. Two dynamic centrifuge tests were designed and conducted to reexamine the Mononobe–Okabe method and to evaluate the seismic lateral earth pressure on an inverted T-shape flexible retaining wall with a dry medium sand backfill. Results from two sets of dynamic centrifuge experiments show that inertial force has a significant impact on the seismic behavior on the flexible retaining wall. The dynamic earth pressure at the time of maximum moment during the earthquake was not synchronized and almost zero. The relationship between the back-calculated dynamic earth pressure coefficient at the time of maximum dynamic wall moment and the peak ground acceleration obtained from the wall base peak ground acceleration indicates that the seismic earth pressure on flexible cantilever retaining walls can be neglected at accelerations below 0.4 g. These results suggest that a wall designed with a static factor of safety should be able to resist seismic loads up to 0.3–0.4 g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号