首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
The effects of soil–structure interaction in yielding systems are evaluated, including both kinematic and inertial interaction. The concepts developed previously for interacting elastic systems are extended to include the non‐linear behavior of the structure. A simple soil–structure system representative of code‐ designed buildings is investigated. The replacement oscillator approach used in practice to account for the elastic interaction effects is adjusted to consider the inelastic interaction effects. This is done by means of a non‐linear replacement oscillator defined by an effective ductility together with the known effective period and damping of the system for the elastic condition. To demonstrate the efficiency of this simplified approach, extensive numerical evaluations are conducted for elastoplastic structures with embedded foundation in a soil layer over elastic bedrock, excited by vertically propagating shear waves. Both strength and displacement demands are computed with and without regard to the effect of foundation flexibility, taking as control motion the great 1985 Michoacan earthquake recorded at a site representative of the soft zone in Mexico City. Results are properly interpreted to show the relative effects of interaction for elastic and yielding systems. Finally, it is demonstrated how to implement this information in the context of code design of buildings. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
A comprehensive parametric study on the inelastic seismic response of seismically isolated RC frame buildings, designed for gravity loads only, is presented. Four building prototypes, with 23 m × 10 m floor plan dimensions and number of storeys ranging from 2 to 8, are considered. All the buildings present internal resistant frames in one direction only, identified as the strong direction of the building. In the orthogonal weak direction, the buildings present outer resistant frames only, with infilled masonry panels. This structural configuration is typical of many existing RC buildings, realized in Italy and other European countries in the 60s and 70s. The parametric study is based on the results of extensive nonlinear response‐time history analyses of 2‐DOF systems, using a set of seven artificial and natural seismic ground motions. In the parametric study, buildings with strength ratio (Fy/W) ranging from 0.03 to 0.15 and post‐yield stiffness ratio ranging from 0% to 6% are examined. Three different types of isolation systems are considered, that is, high damping rubber bearings, lead rubber bearings and friction pendulum bearings. The isolation systems have been designed accepting the occurrence of plastic hinges in the superstructure during the design earthquake. The nonlinear response‐time history analyses results show that structures with seismic isolation experience fewer inelastic cycles compared with fixed‐base structures. As a consequence, although limited plastic deformations can be accepted, the collapse limit state of seismically isolated structures should be based on the lateral capacity of the superstructure without significant reliance on its inherent hysteretic damping or ductility capacity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
It is widely accepted that ductility design improves the seismic capacity of structures worldwide. Nevertheless, inelastic deformation allows serious damage to occur in structures. Previous studies have shown that a certain level of postyield stiffness may reduce both the peak displacement and residual deformation of a structure. In recent years, several high-strength elastic materials, such as fiber-reinforced polymer (FRP) and high-strength steel bars, have been developed. Application of these materials can easily provide a structure with a much higher and more stable postyield stiffness. Many materials, members, and structures that incorporate both high-strength elastic materials and conventional materials show significant postyield hardening (PYH) behaviors. The significant postyield stiffness of PYH structures can help effectively reduce both peak and residual deformations, providing a choice when designing resilient structures. However, the findings of previous studies of structures with elastic-perfectly plastic (EPP) behavior or small postyield stiffness may not be accurate for PYH structures. The postyield stiffness of a structure must be considered an important primary structural parameter, in addition to initial stiffness, yielding strength, and ductility. In this paper, extensive time history and statistical analyses are carried out for PYH single–degree-of-freedom (SDOF) systems. The mean values and coefficients of variation of the peak displacement and residual deformation are obtained and discussed. A new R-μp-T-α relationship and damage index for PYH structures are proposed. A theoretical model for the calculation of residual deformation is also established. These models provide a basis for developing the appropriate seismic design and performance evaluation procedures for PYH structures.  相似文献   

6.
One of the founders of structural control theory and its application in civil engineering,Professor Emeritus Tsu T.Soong,envisioned the development of the integral design of structures protected by active control devices.Most of his disciples and colleagues continuously attempted to develop procedures to achieve such integral control.In his recent papers published jointly with some of the authors of this paper,Professor Soong developed design procedures for the entire structure using a design-redesign proce...  相似文献   

7.
Coupling between lateral and torsional motions may lead to much larger edge deformations in asymmetric-plan systems compared to systems with a symmetric plan. Supplemental viscous damping has been found to be effective in reducing deformations in the symmetric-plan system. This investigation examined how supplemental damping affects the edge deformations in asymmetric-plan systems. First, the parameters that characterize supplemental viscous damping and its plan-wise distribution were identified, and then the effects of these parameters on edge deformations were investigated. It was found that supplemental damping reduces edge deformations and that reductions by a factor of up three are feasible with proper selection of system parameters. Furthermore, viscous damping may be used to reduce edge deformations in asymmetric-plan systems to levels equal to or smaller than those in the corresponding symmetric-plan system. © 1998 John Wiley & Sons, Ltd.  相似文献   

8.
Estimation of peak inelastic deformation demands is a key component of any displacement-based procedure for earthquake-resistant design of new structures or for seismic evaluation of existing structures. On the basis of the results of over a thousand non-linear dynamic analyses, rules are developed for the estimation of mean and upper-characteristic peak inelastic interstorey drifts and member chord rotations in multistorey RC frame buildings, either bare or infilled in all storeys but the first. For bare frame structures, mean inelastic deformation demands can be estimated from a linear, equivalent static, or preferably multimodal response spectrum analysis with 5 per cent damping and with the RC members considered with their secant stiffness at yielding. 95 per cent characteristic values can be estimated as multiples of the mean deformations. For open-first-storey buildings, the linear analysis can be equivalent static, with the infills modelled as rigid bidiagonal struts and all RC members considered with their secant stiffness to yielding. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

9.
The seismic performance of existing structures can be assessed based on nonlinear static procedures, such as the Capacity Spectrum Method. This method essentially approximates peak responses of an inelastic single‐degree‐of‐freedom (SDOF) system using peak responses of an equivalent linear SDOF model. In this study, the equivalent linear models of inelastic SDOF systems are developed based on the constant strength approach, which does not require iteration for assessing the seismic performance of existing structures. To investigate the effects of earthquake type and seismic region on the equivalent linear models, four ground‐motion data sets—Japanese crustal/interface/inslab records and California crustal records—are compiled and used for nonlinear dynamic analysis. The analysis results indicate that: (1) the optimal equivalent linear model parameters (i.e. equivalent vibration period ratio and damping ratio) decrease with the natural vibration period, whereas they increase with the strength reduction factor; (2) the impacts of earthquake type and seismic region on the equivalent linear model parameters are not significant except for short vibration periods; and (3) the degradation and pinching effects affect the equivalent linear model parameters. We develop prediction equations for the optimal equivalent linear model parameters based on nonlinear least‐squares fitting, which improve and extend the current nonlinear static procedure for existing structures with degradation and pinching behavior. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
This paper investigates the effects of supplemental viscous damping on the seismic response of one‐storey, asymmetric‐plan systems responding in the inelastic range of behaviour. It was found that addition of the supplemental damping reduces not only deformation demand but also ductility and hysteretic energy dissipation demands on lateral load resisting elements during earthquake loading. However, the level of reduction strongly depends on the plan‐wise distribution of supplemental damping. Nearly optimal reduction in demands on the outermost flexible‐side element, an element generally considered to be the most critical element, was realized when damping was distributed unevenly in the system plan such that the damping eccentricity was equal in magnitude but opposite in algebraic sign to the structural eccentricity of the system. These results are similar to those noted previously for linear elastic systems, indicating that supplemental damping is also effective for systems expected to respond in the inelastic range. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

11.
A generalized pushover analysis (GPA) procedure is developed for estimating the inelastic seismic response of structures under earthquake ground excitations. The procedure comprises applying different generalized force vectors separately to the structure in an incremental form with increasing amplitude until a prescribed seismic demand is attained for each generalized force vector. A generalized force vector is expressed as a combination of modal forces, and simulates the instantaneous force distribution acting on the system when a given response parameter reaches its maximum value during dynamic response to a seismic excitation. While any response parameter can be selected arbitrarily, generalized force vectors in the presented study are derived for maximum interstory drift parameters. The maximum value of any other response parameter is then obtained from the envelope of GPAs results. Each nonlinear static analysis under a generalized force vector activates the entire multi‐degree of freedom effects simultaneously. Accordingly, inelastic actions develop in members with the contribution of all ‘instantaneous modes’ in the nonlinear response range. Target seismic demands for interstory drifts at the selected stories are calculated from the associated drift expressions. The implementation of the proposed GPA is simpler compared with nonlinear response history analysis, whereas it is less demanding in computational effort when compared with several multi‐mode adaptive nonlinear static procedures. Moreover, it does not suffer from the statistical combination of inelastic modal responses obtained separately. The results obtained from building frames have demonstrated that GPA is successful in estimating maximum member deformations and member forces with reference to the response history analysis. When the response is linear elastic, GPA and response spectrum analysis produce identical results. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
The primary purpose of this research is to improve the seismic response of a complex asymmetric tall structure using viscoelastic(VE) dampers. Asymmetric structures have detrimental effects on the seismic performance because such structures create abrupt changes in the stiffness or strength that may lead to undesirable stress concentrations at weak locations. Structural control devices are one of the effective ways to reduce seismic impacts, particularly in asymmetric structures. For passive vibration control of structures, VE dampers are considered among the most preferred devices for energy dissipation. Therefore, in this research, VE dampers are implemented at strategic locations in a realistic case study structure to increase the level of distributed damping without occupying significant architectural space and reducing earthquake vibrations in terms of story displacements(drifts) and other design forces. It has been concluded that the seismic response of the considered structure retrofitted with supplemental VE dampers corresponded well in controlling the displacement demands. Moreover, it has been demonstrated that seismic response in terms of interstory drifts was effectively mitigated with supplemental damping when added up to a certain level. Exceeding the supplemental damping from this level did not contribute to additional mitigation of the seismic response of the considered structure. In addition, it was found that the supplemental damping increased the total acceleration of the considered structure at all floor levels, which indicates that for irregular tall structures of this type, VE dampers were only a good retrofitting measure for earthquake induced interstory deformations and their use may not be suitable for acceleration sensitive structures. Overall, the research findings demonstrate how seismic hazards to these types of structures can be reduced by introducing additional damping into the structure.  相似文献   

13.
The concept of effective eccentricity is generalized for inelastic systems to provide guidelines for estimating the maximum dynamic edge displacement and resisting element deformation of a single mass monosymmetrical system subjected to unidirectional ground excitations. Inelastic responses of three structural models having the same overall elastic responses are compared and the model which generally results in larger edge displacement is chosen as the structural model to be used to evaluate the effect of asymmetry. The inelastic effective eccentricity is calculated for different values of the system parameters, based on an ensemble of six ground motion records as input. It is concluded that, except for stiff structures having low yield strength, the elastic effective eccentricity curves developed previously by Dempsey and Tso can provide a reasonable or relatively conservative estimate for inelastic effective eccentricity, and these curves can be used to estimate the edge displacement and element deformation of inelastic eccentric systems.  相似文献   

14.
Constant-ductility strength demand spectra for seismic design of structures   总被引:1,自引:0,他引:1  
In displacement-based seismic design, constant-ductility strength demand spectra (CDSDS) are very useful for preliminary design of new structures where the global displacement ductility capacity is known. The CDSDS can provide the required inelastic lateral strength of new structures from the required elastic lateral strength. Based on a statistical study of nonlinear time-history for an SDOF system, the mean CDSDS corresponding to four site conditions are presented and approximate expressions of the inelastic spectra are proposed, which are functions of the structural period and ductility level. The effects of site conditions, structural period, level of ductility, damping and post-yield stiffness of structures on CDSDS are also investigated. It is concluded that site conditions, ductility level and structural period have important effects on the CDSDS and damping, post-yield stiffness effects are rather complex and of minor importance. The damping, post-yield stiffness effects depend on both the level of ductility and the natural period of structures.  相似文献   

15.
This paper presents a statistical study of the kinematic soil-foundation-structure interaction effects on the maximum inelastic deformation demands of structures. Discussed here is the inelastic displacement ratio defined as the maximum inelastic displacement demands of structures subjected to foundation input motions divide by those of structures subjected to free-field ground motions. The displacement ratio is computed for a wide period range of elasto-plastic single-degree-of-freedom (SDOF) systems with various levels of lateral strength ratios and with different sizes of foundations. Seventy-two earthquake ground motions recorded on firm soil with average shear wave velocities between 180 m/s and 360 m/s are adopted. The effects of period of vibration, level of lateral yielding strength and dimension of foundations are investigated. The results show that kinematic interaction will reduce the maximum inelastic displacement demands of structures, especially for systems with short periods of vibration, and the larger the foundation size the smaller the maximum inelastic displacement becomes. In addition, the inelastic displacement ratio is nearly not affected by the strength ratio of structures for systems with periods of vibration greater than about 0.3 s and with strength ratios smaller than about 3.0. Expressions obtained from nonlinear regression analyses are also proposed for estimating the effects of kinematic soil-foundation-structure interaction from the maximum deformation demand of the inelastic system subjected to free-field ground motions.  相似文献   

16.
The inelastic responses of framed structures and seismic isolation systems undergoing biaxial (horizontal) shaking are coupled. In existing models for biaxial coupling of hysteretic behavior, the smoothness (or ‘knee') of the transition from elastic to yielding behavior cannot be modified without affecting the shape of the yield surface. This paper presents a model for coupled biaxial hysteretic behavior in which the knee from pre‐yield to post‐yield can be adjusted while maintaining an isotropic yield surface. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
The inelastic response of one-storey, asymmetric-plan systems to two excitations is presented and analysed with the objective of identifying the influence of system parameters: uncoupled lateral vibration period, uncoupled torsional-to-lateral frequency ratio, stiffness eccentricity, relative values of the strength and stiffness eccentricities, and yield factor. Furthermore, the influence of yielding on the response of asymmetric-plan systems is examined. In particular, we determine whether the well known relationship between the response of yielding and elastic single-degree-of-freedom (SDF) systems is also applicable to asymmetric-plan systems.  相似文献   

18.
The unloading parameters of hysteretic models for RC members are given in terms of their shear-span-to-depth ratio and the viscous damping used to model other energy dissipation sources. They reflect the energy dissipation in full post-yield load cycles in 534 tests of rectangular or circular members. Pre-yield hysteretic energy dissipation—ignored if the model is elastic till yielding—amounts in the tests to a mean viscous damping around 8.5% and can be considered in nonlinear response-history analysis through a new model which combines constant elastic stiffness in virgin loading with hysteretic energy dissipation both before and after yielding. Models with linear behavior till yielding and hysteretic energy dissipation only after it come closer to the results of the new model if viscous damping is 5%.  相似文献   

19.
This paper deals with the estimation of peak inelastic displacements of SDOF systems, representative of typical steel structures, under constant relative strength scenarios. Mean inelastic deformation demands on bilinear systems (simulating moment resisting frames) are considered as the basis for comparative purposes. Additional SDOF models representing partially‐restrained and concentrically‐braced (CB) frames are introduced and employed to assess the influence of different force‐displacement relationships on peak inelastic displacement ratios. The studies presented in this paper illustrate that the ratio between the overall yield strength and the strength during pinching intervals is the main factor governing the inelastic deformations of partially‐restrained models and leading to significant differences when compared with predictions based on bilinear structures, especially in the short‐period range. It is also shown that the response of CB systems can differ significantly from other pinching models when subjected to low or moderate levels of seismic demand, highlighting the necessity of employing dedicated models for studying the response of CB structures. Particular attention is also given to the influence of a number of scalar parameters that characterise the frequency content of the ground motion on the estimated peak displacement ratios. The relative merits of using the average spectral period Taver, mean period Tm, predominant period Tg, characteristic period Tc and smoothed spectral predominant period To of the earthquake ground motion, are assessed. This paper demonstrates that the predominant period, defined as the period at which the input energy is maximum throughout the period range, is the most suitable frequency content scalar parameter for reducing the variability in displacement estimations. Finally, noniterative equivalent linearisation expressions based on the secant period and equivalent damping ratios are presented and verified for the prediction of peak deformation demands in steel structures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
This work discusses the simplified estimation of earthquake‐induced nonlinear displacement demands as required by nonlinear static procedures, with particular attention on short‐period masonry structures. The study focuses on systems with fundamental periods between 0.1 and 0.5 s, for which inelastic amplification of the elastic displacement demand is more pronounced; hysteretic force‐displacement relationships characteristic of masonry structures are adopted, because these structures are more commonly found within the considered period range. Referring to the results of nonlinear dynamic analyses of single‐degree‐of‐freedom oscillators, some limitations of the Eurocode 8 and Italian Building Code formulations are first discussed, then an improved equation is calibrated that relates inelastic and elastic displacement demands. Numerical values of the equation parameters are obtained, considering the amount of hysteretic energy dissipation associated with various damage mechanisms observed in masonry structures. Safety factors are also calculated to determine several percentiles of the displacement demand. It is shown that the proposed equation can be extended to more dissipative systems. Finally, the same formulation is adapted to the estimation of seismic displacements when elastic analysis procedures are employed. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号