首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The chemical compositions of a total of 120 thermal water samples from four different tectonically distinct regions (Central, North, East and West Anatolia) of Turkey are presented and assessed in terms of geothermal energy potential of each region through the use of chemical geothermometers. Na–Ca–HCO3 type waters are the dominant water types in all the regions except that Na–Cl type waters are typical for the coastal areas of West Anatolia and for a few inland areas of West and Central Anatolia where deep water circulation exists. The discharge temperature of the springs ranges up to 100°C, and the bottom-hole temperatures in drilled wells up to 232°C. Geothermometry applications yield reservoir temperatures of about 125°C for Central Anatolia, 110°C for North Anatolia, 136°C for East Anatolia and 251°C for West Anatolia, the latter agreeing with some of the bottom hole temperatures measured in drilled wells. The results reveal that the highest geothermal energy potential in Turkey is associated with the West Anatolian extensional tectonics which provides a regional, deep-seated heat source and a widespread graben system allowing deep circulation of waters. The North Anatolian region, bounded to the south by the dextral North Anatolian Fault along which most of the geothermal sites are located, has the lowest energy potential, probably due to the restriction of the heat source to local magmatic activities confined to pull-apart basins. The East Anatolian region (undergoing contemporary compression) and the Central Anatolian region (where the compressional regime in the east is converted to the extensional regime in the west) have moderate energy potential. Although the recently active volcanoes suggest the presence, at depth, of still cooling magma chambers that are potential heat sources, the lack of well-developed fault systems is probably responsible for the comparatively low energy potential of these regions. Almost all the thermal waters of Turkey are saturated with respect to calcite and, hence, have a significant calcite scaling potential which is particularly high for West Anatolian waters.  相似文献   

2.
On the evolution of the geothermal regime of the North China Basin   总被引:1,自引:0,他引:1  
Recent heat flow and regional geothermal studies indicate that the North China Basin is characterized by relatively high heat flow compared with most stable areas in other parts of the world, but lower heat flow than most active tectonic areas. Measured heat flow values range from 61 to 74 mW m−2. The temperature at a depth of 2000 m is generally in the range 75 to 85°C, but sometimes is 90°C or higher. The geothermal gradient in Cenozoic sediments is in the range 30 to 40°C/km for most of the area. The calculated temperature at the Moho is 560 and 640°C for surface heat flow values of 63 and 71 mW m−2, respectively. These thermal data are consistent with other geophysical observations for the North China Basin. Relatively high heat flow in this area is related to Late Cretaceous-Paleogene rifting as described in this paper.  相似文献   

3.
Temperatures of aquifers feeding thermal springs and wells in Long Valley, California, estimated using silica and Na-K-Ca geothermometers and warm spring mixing models, range from 160/dg to about 220°C. This information was used to construct a diagram showing enthalpy-chloride relations for the various thermal waters in the Long Valley region. The enthalpy-chloride information suggests that a 282 ± 10°C aquifer with water containing about 375 mg chloride per kilogram of water is present somewhere deep in the system. That deep water would be related to 220°C Casa Diablo water by mixing with cold water, and to Hot Creek water by first boiling with steam loss and then mixing with cold water. Oxygen and deuterium isotopic data are consistent with that interpretation. An aquifer at 282°C with 375 mg/kg chloride implies a convective heat flow in Long Valley of 6.6 × 107 cal/s.  相似文献   

4.
Results of a chemical study of the fluids from drill holes and hot springs of Puga and Chumatang areas in the northwestern part of the Himalaya are presented and discussed in this paper. The thermal waters of Puga and Chumatang are of Na-HCO3-Cl and Na-HCO3 types, respectively. A comparison between these waters, their chemical classification and activity studies suggest a flow path within a quartzitic-schistose basement, containing quartz, K-feldspar and illite, and in clayey terrains containing montmorillonite and illite.The chemistry of thermal waters also indicate their association with magmatic activity. The chemical geothermometers indicate the possible existence of a geothermal reservoir at Puga with temperature ≈250°C. The Chumatang area has a comparatively cooler reservoir with a temperature of 150–180°C.  相似文献   

5.
Studies of the geology, geochemistry of thermal waters, and of one exploratory geothermal well show that two related hot spring systems discharge in Canõn de San Diego at Soda Dam (48°C) and Jemez Springs (72°C). The hot springs discharge from separate strands of the Jemez fault zone which trends northeastward towards the center of Valles Caldera. Exploration drilling to Precambrian basement beneath Jemez Springs encountered a hot aquifer (68°C) at the top of Paleozoic limestone of appropriate temperature and composition to be the local source of the fluids in the surface hot springs at Jemez Springs. Comparisons of the soluble elements Na, Li, Cl, and B, arguments based on isotopic evidence, and chemical geothermometry indicate that the hot spring fluids are derivatives of the deep geothermal fluid within Valles Caldera. No hot aquifer was discovered in or on top of Precambrian basement. It appears that low- to moderate-temperature geothermal reservoirs (< 100°C) of small volume are localized along the Jemez fault zone between Jemez Springs and the margin of Valles Caldera.  相似文献   

6.
Geothermal studies have been conducted in China continuously since the end of the 1950's with renewed activity since 1970. Three areas of research are defined: (1) fundamental theoretical research on geothermics, including subsurface temperatures, terrestrial heat flow and geothermal modeling; (2) exploration for geothermal resources and exploitation of geothermal energy; and (3) geothermal studies in mines.Regional geothermal studies have been conducted recently in North China and more than 2000 values of subsurface temperature have been obtained. Temperatures at a depth of 300 m generally range from 20 to 25°C with geothermal gradients from 20 to 40°C/km. These values are regarded as an average for the region with anomalies related to geological factors.To date, 22 reliable heat flow data from 17 sites have been obtained in North China and the data have been categorized according to fault block tectonics. The average heat flow value at 16 sites in the north is 1.3 HFU, varying from 0.7 to 1.8 HFU. It is apparent that the North China fault block is characterized by a relatively high heat flow with wide variations in magnitude compared to the mean value for similar tectonic units in other parts of the world. It is suggested that although the North China fault block can be traced back to the Archaean, the tectonic activity has been strengthening since the Mesozoic resulting in so-called “reactivation of platform” with large-scale faulting and magmatism.Geothermal resources in China are extensive; more than 2000 hot springs have been found and there are other manifestations including geysers, hydrothermal explosions, hydrothermal steam, fumaroles, high-temperature fountains, boiling springs, pools of boiling mud, etc. In addition, there are many Meso-Cenozoic sedimentary basins with widespread aquifers containing geothermal water resources in abundance. The extensive exploration and exploitation of these geothermal resources began early in the 1970's. Since then several experimental power stations using thermal water have been set up in Fengshun (Fungshun),  相似文献   

7.
Application of various chemical geothermometers and mixing models indicate underground temperatures of 260°C, 280°C and 265°C in the Geysir, Hveravellir and Landmannalaugar geothermal fields in Iceland, respectively. Mixing of the hot water with cold water occurs in the upflow zones of all these geothermal systems. Linear relations between chloride, boron and δ18O constitute the main evidence for mixing, which is further substantiated by chloride, silica and sulphate relations in the Geysir and Hveravellir fields.A new carbonate-silica mixing model is proposed which is useful in distinguishing boiled and non-boiled geothermal waters. This model can also be used to estimate underground temperatures using data from warm springs. This model, as well as the chloride-enthalpy model and the Na-Li, and CO2-gas geothermometers, invariably yield similar results as the quartz geothermometer sometimes also does. By contrast, the Na-K and the Na-K-Ca geothermometers yield low values in the case of boiling hot springs, largely due to loss of potassium from solution in the upflow. The results of these geothermometers are unreliable for mixed waters due to leaching subsequent to mixing.  相似文献   

8.
Shallow submarine hydrothermal activity has been observed in the Bahía Concepción bay, located at the Gulf coast of the Baja California Peninsula, along faults probably related to the extensional tectonics of the Gulf of California region. Diffuse and focused venting of hydrothermal water and gas occurs in the intertidal and shallow subtidal areas down to 15 m along a NW–SE-trending onshore–offshore fault. Temperatures in the fluid discharge area vary from 50 °C at the sea bottom up to 87 °C at a depth of 10 cm in the sediments.Chemical analyses revealed that thermal water is enriched in Ca, As, Hg, Mn, Ba, HCO3, Li, Sr, B, I, Cs, Fe and Si, and it has lower concentrations of Cl, Na, SO4 and Br than seawater. The chemical characteristics of the water samples indicate the occurrence of mixing between seawater and a thermal end-member. Stable isotopic oxygen and hydrogen composition of thermal samples plot close to the Local Meteoric Water Line on a mixing trend between a thermal end-member and seawater. The composition of the thermal end-member was calculated from the chemistry of the submarine samples data by assuming a negligible amount of Mg for the thermal end-member. The results of the mixing model based on the chemical and isotopic composition indicate a maximum of 40% of the thermal end-member in the submarine vent fluid.Chemical geothermometers (Na/Li, Na–K–Ca and Si) were applied to the thermal end-member concentration and indicate a reservoir temperature of approximately 200 °C. The application of K–Mg and Na/Li geothermometers for vent fluids points to a shallow equilibrium temperature of about 120 °C.Results were integrated in a hydrogeological conceptual model that describes formation of thermal fluids by infiltration and subsequent heating of meteoric water. Vent fluid is generated by further mixing with seawater.  相似文献   

9.
Geochemical studies on fifteen geothermal manifestations (38–70°C) from the Konkan coast geothermal province of India have been used to evaluate the reservoir temperatures. Activity studies of the minerals and the waters present in the reservoirs suggest that the thermal waters are in equilibrium with montmorillonite, kaolinite and quartz at about 100°C. Reservoir temperatures of these geothermal systems as estimated by geochemical thermometers, are 88 to 128°C, and thus too low for economic electricity production.  相似文献   

10.
Thermal waters of the Ömer–Gecek geothermal field, Turkey, with temperatures ranging from 32 to 92°C vary in chemical composition and TDS contents. They are generally enriched in Na–Cl–HCO3 and suggest deep water circulation. Silica and cation geothermometers applied to the Ömer–Gecek thermal waters yield reservoir temperatures of 75–155°C. The enthalpy–chloride mixing model, which approximates a reservoir temperature of 125°C for the Ömer–Gecek field, accounts for the diversity in the chemical composition and temperature of the waters by a combination of processes including boiling and conductive cooling of deep thermal water and mixing of the deep thermal water with cold water. It is also determined that the solubility of silica in most of the waters is controlled by the chalcedony phase. Equilibrium states of the Ömer–Gecek thermal waters studied by means of the Na–K–Mg triangular diagram, Na–K–Mg–Ca diagram, K–Mg–Ca geoindicator diagram, activity diagrams in the systems composed of Na2O–CaO–K2O–Al2O3–SiO2–CO2–H2O phases, log SI diagrams, and finally the alteration mineralogy indicate that most of the spring and low-temperature well waters in the area can be classified as shallow or mixed waters which are likely to be equilibrated with calcite, chalcedony and kaolinite at predicted temperature ranges similar to those calculated from the chemical geothermometers. It was also observed that mineral equilibrium in the Ömer–Gecek waters is largely controlled by CO2 concentrations.  相似文献   

11.
The Platanares geothermal area, Departamento de Copán, Honduras, is located within a graben that is complexly faulted. The graben is bounded on the north by a highland composed of Paleozoic (?) metamorphic rocks in contact with Cretaceous - Tertiary redbeds of unknown thickness. These are unconformably overlain by Tertiary andesitic lavas, rhyolitic ignimbrites, and associated sedimentary rocks. The volcanic rocks are mostly older than 14 Ma, and thus are too old to represent the surface expression of an active crustal magma body. Thermal fluids that discharge in the area are heated during deep circulation of meteoric water along faults in a region of somewhat elevated heat flow. Geothermometry based upon the chemical composition of thermal fluids from hot springs and from geothermal gradient coreholes suggests that the reservoir equilibrated at temperatures as high as 225 to 240°C, within the Cretaceous redbed sequence. Three continuously cored geothermal gradient holes have been drilled; fluids of about 165°C have been produced from two drilled along a NW-trending fault zone, from depths of 250 to 680 m. A conductive thermal gradient of 139°C/km, at a depth of 400 m, was determined from the third well, drilled 0.6 km west of that fault zone. These data indicate that the Platanares geothermal area holds considerable promise for electrical generation by moderate- to hightemperature geothermal fluids.  相似文献   

12.
Results of drilling, logging, and testing of three exploration core holes, combined with results of geologic and hydrogeochemical investigations, have been used to present a reservoir model of the Platanares geothermal system, Honduras. Geothermal fluids circulate at depths ≥ 1.5 km in a region of active tectonism devoid of Quaternary volcanism. Large, artesian water entries of 160 to 165°C geothermal fluid in two core holes at 625 to 644 m and 460 to 635 m depth have maximum flow rates of roughly 355 and 560 l/min, respectively, which are equivalent to power outputs of about 3.1 and 5.1 MW(thermal). Dilute, alkali-chloride reservoir fluids (TDS ≤ 1200 mg/kg) are produced from fractured Miocene andesite and Cretaceous to Eocene redbeds that are hydrothermally altered. Fracture permeabillity in producing horizons is locally greater than 1500 and bulk porosity is ≤ 6%. A simple, fracture-dominated, volume-impedance model assuming turbulent flow indicates that the calculated reservoir storage capacity of each flowing hole is approximately 9.7 × 106 l/(kg cm−2), Tritium data indicate a mean residence time of 450 yr for water in the reservoir. Multiplying the natural fluid discharge rate by the mean residence time gives an estimated water volume of the Platanares system of ≥ 0.78 km3. Downward continuation of a 139°C/km “conductive” gradient at a depth of 400 m in a third core hole implies that the depth to a 225°C source reservoir (predicted from chemical geothermometers) is at least 1.5 km. Uranium-thorium disequilibrium ages on calcite veins at the surface and in the core holes indicate that the present Platanares hydrothermal system has been active for the last 0.25 m.y.  相似文献   

13.
The Ischia geothermal system is hosted by silicic rocks of the Quaternary Potassic Roman Province, in southern Italy. Exploration drilling down to 1156 m depth in the mid-1950s provided information on boiling profiles (up to 250°C) and on the depth and permeability of the potential reservoirs. Discharge fluid samples were collected and analyzed to define the inflow of surrounding seawater (C1 ranges from 2.5 to 20 g/kg) into the system.Analyses of samples from surface manifestations and shallow wells collected during 1983 and 1988 point to the existence of three distinct mixing regimes, involving three water components. A dishomogeneous body of diluted water (Cl less than 2.5 g/kg), that occurs at depths > 700 m and reequilibrates at 240°C at least, is overlain by an aquifer of groundwater variably mixed with variably seawater (Cl from 4 to 10 g/kg), which tends to reequilibrate at 160°C. Steam-heated waters locally develop and act as dilutants of the rising geothermal fluids.Dilution, mixing, and evaporation of the ascending chloride fluids are supported by oxygen and hydrogen isotopic data the thermal waters being enriched in 18O and D with respect to local meteoric water by up to 7 and 30‰, respectively. The relative composition of the major cations in thermal solutions was used to discriminate the two main groups of thermal waters, the reservoir temperatures of which are estimated from the Na/K-gethermometer. K-Mg geothermometer indicates reequilibration in near-surface conditions.The isotopic composition of the fumarolic steam varies from −7 to −12‰ in ∂8O and from − 35 to − 70‰ in ∂D, in agreement with a deep mixed fluid that boils adiabatically from 240 to 80°C. The deuterium content of the H2O-H2 pair gives enrichment factor of about 830‰, corresponding to equilibrium temperature conditions slightly higher than the surface boiling temperatures. The ∂13C of CO2is almost constant at −4.5‰ (1δ=0.4), suggesting an important magmatic contribution, and the ∂18O values of CO2appears to in equilibrium with accompanying steam at the measured temperatures.The CO2/Ar and H2/Ar chemical ratios have been used to derive aquifer temperatures, the values obtained being consistent with those of solute geothermometers.  相似文献   

14.
The Blackfoot Reservoir region in southeastern Idaho is recognized as a potential geothermal area because of the presence of several young rhyolite domes (50,000 years old), Quaternary basalt flows, and warm springs. North- to northwest-trending high-angle normal faults of Tertiary to Holocene age appear to be the dominant structural control of spring activity. Surface spring-water temperatures average 14°C except for a group of springs west of the Reservoir Mountains which average 33°C. Chemical geothermometers applied to fifty water samples give temperatures less than 75°C except for eight springs along the Corral Creek drainage. The springs along Corral Creek have Na-K-Ca temperatures that average 354°C, a direct result of high potassium concentrations in the water. A correction for carbon dioxide applied to the Na-K-Ca geothermometer lowers the estimated temperatures of the anomalous springs to near the measured surface temperatures, and Na-K-Ca-Mg temperatures for the anomalous springs are near 100°C. Mixing model calculations suggest that hot water with a temperature of approximately 120°C may be mixing with cooler, more dilute water in the springs from the Corral Creek drainage, a temperature supported by Na-K-Ca-Mg temperatures and mineral saturation temperatures.Stability relations of low-temperature phases in the system indicate that the large concentrations of potassium in the eight anomalous springs are derived from reactions with the potassium-bearing minerals muscovite and K-feldspar. Carbon dioxide and hydrogen sulfide gases may be derived through the oxidation of organic matter accompanied by the reduction of sulfate. Concentrations of major and minor elements, and gases found in springs of the Blackfoot Reservoir region are due to water-rock reactions at temperatures less than 100°C.Based on spring geochemistry, a geothermal reservoir of 100°C up to 120°C may exist at shallow (less than 2 km) depths in the Blackfoot Reservoir region.  相似文献   

15.
Thermal waters hosted by Menderes metamorphic rocks emerge along fault lineaments in the Simav geothermal area. Thermal springs and drilled wells are located in the Eynal, Çitgöl and Na a locations, which are part of the Simav geothermal field. Studies were carried out to obtain the main chemical and physical characteristics of thermal waters. These waters are used for heating of residences and greenhouses and for balneological purposes. Bottom temperatures of the drilled wells reach 163°C with total dissolved solids around 2225 mg/kg. Surface temperatures of thermal springs vary between 51°C and 90°C. All the thermal waters belong to Na–HCO3–SO4 facies. The cold groundwaters are Ca–Mg–HCO3 type. Dissolution of host rock and ion-exchange reactions in the reservoir of the geothermal system shift the Ca–Mg–HCO3 type cold groundwaters to the Na–HCO3–SO4 type thermal waters. Thermal waters are oversaturated at discharge temperatures for aragonite, calcite, quartz, chalcedony, magnesite and dolomite minerals giving rise to a carbonate-rich scale. Gypsum and anhydrite minerals are undersaturated with all of the thermal waters. Boiling during ascent of the thermal fluids produces steam and liquid waters resulting in an increase of the concentrations of the constituents in discharge waters. Steam fraction, y, of the thermal waters of which temperatures are above 100°C is between 0.075 and 0.119. Reservoir pH is much lower than pH measured in the liquid phase separated at atmospheric conditions, since the latter experienced heavy loss of acid gases, mainly CO2. Assessment of the various empirical chemical geothermometers and geochemical modelling suggest that reservoir temperatures vary between 175°C and 200°C.  相似文献   

16.
Hydrothermal clay minerals present in the Broadlands–Ohaaki geothermal field were characterised by field portable short-wave infrared spectroscopy. Three major alteration zones, an upper smectite, a middle illite and a lower illite–chlorite, are spectrally separable. The zoning pattern is generally consistent with the thermal structure of the geothermal field, although occasionally zone boundaries cut present-day isotherms. The data indicate that temperature is the major control on clay zoning and permeability plays a subordinate role.Both beidellite and montmorillonite are common in the upper, low-temperature smectite zone. Kaolinite, mainly of low crystallinity, marks the margin of the field where cool acidic ground waters inflow. In the middle alteration zone, illite, dominantly K-rich, shows a narrow compositional variability. Some highly permeable zones are characterised by illite with low octahedral Al contents. Ammonium-bearing illite and buddingtonite are present locally in permeable horizons within the illite zone, where temperatures are above 200°C. Chlorite is most abundant in the lower alteration zone (temperature >250°C), although it also occurs unevenly in the upper and middle alteration zones. Chlorite varies from Mg- to Fe-rich varieties (but mostly with Mg# values <0.5), but no compositional trends with respect to depth are spectrally detectable.  相似文献   

17.
During 1979–1989, variations were observed in the oxygen composition of the water contained in the geothermal reservoir at Vulcano Island, Italy.The reservoir water, that has a magmatic origin, showed an oxygen composition of +1.0±0.5‰ δ18O during periods without local tectonic earthquakes, and an oxygen composition of +3.4±0.5‰ δ18O after the highest-energy seismic activity that occurred recently near the island. A slight increase of the δ18O value in the reservoir water was also observed after a low-energy sequence of tectonic earthquakes that occurred at very shallow depth just beneath Vulcano Island. These 18O variations in the reservoir water are consistent with earthquake-induced increases in the contribution from high-temperature δ18O-rich magmatic condensate to the geothermal reservoir, and with subsequent decreases in the δ18O value due to 18O exchanges at the temporarily increased reservoir temperature during reactions between the highly reactive magmatic condensate and the local rocks.Only minor changes in the deuterium composition of the reservoir water occurred with time, as the δD value in the magmatic condensate released from the magma after major local earthquakes quickly approached the δD value of the water contained in the geothermal reservoir.Also the chloride concentration in the reservoir water appears to be linked to the contribution from the magmatic fluid. This chloride content seems not to have undergone major changes with time, as it may be buffered by temporary increases in the reservoir temperature up to values >300°C induced by major local earthquakes. This mechanism may possibly occur also in other magmatic–hydrothermal systems.  相似文献   

18.
Results are presented on scubadiving investigations carried out on thermal manifestations in the area of Panarea (Aeolian Islands). The area investigated falls inside a caldera which extends from the main island to the group of islets located to the northeast. The distribution of the gaseous manifestations is regulated by the NE-SW, NW-SE and N-S regional tectonic directrices, through which the more recent basic magma intruded, giving rise to dikes and pillow lavas. fO2-temperature relation of the gases sampled in the investigated area was calculated to be: logfO2 = 11−24,593/T which indicates that a buffering mechanism acted on the gases as they cooled down during their ascent. The high 3He/4He ratio (6 × 10−6) and the δ13C = −3.2%. (PDB), suggest the presence of a magmatic component in the gas feeding the investigated manifestations. The above relations and the almost constant high He/N2 ratio suggest that all the fumaroles are fed by the same deep hot fluids. On the basis of both the chemical characters of the fluids and the geothermo-barometric data, a deep geothermal body, having a temperature of about 240°C, is recognized. Two other shallower thermal aquifers, with a temperature of 170–210°C, are identified. A circulation pattern of the geothermal fluids is also proposed. On the basis of calculations regarding the convective energy released by the geothermal system of Panarea, and the magmatic mass responsible for the positive gravimetric anomaly of the area, it was estimated that the last volcanic activity took place less then 10,000 years ago.  相似文献   

19.
Philippine geothermal systems occur in the vicinity of large Holocene calc-alkaline volcanic complexes. Wells drilled in these areas encountered multiple intrusions; the latest dikes are the subsurface manifestations of the youngest heat source. Commonly, at least two hydrothermal regimes are juxtaposed in a single area, with the latest being in equilibrium with the present temperature and chemical regime.Alteration by neutral-pH water is pervasive and abundant. A contact-metamorphic aureole also occurs near intrusives. Alteration due to acid-sulfate fluids is generally confined to permeable structures. Neutral-pH alteration is divided into four zones on the basis of key clay minerals, and two subzones are defined by calc-silicates. These are the smectite (ambient to 180°C), transition (180–230°C), illite (230–320°C) and biotite (270–340°C) zones. Subzones are defined by epidote (250–340°C) and amphibole (280–340°C). The four main zones of acid alteration are: kaolinite (ambient to 120°C), dickite ± kaolinite (120–200°C), dickite ± pyrophyllite (200–250°C), and pyrophyllite ± illite (230–320°C). Where relict high-temperature alteration reaches the surface, the area being drilled is usually the outflow zone of the present system.These hydrothermal mineral assemblages are used: (1) as geothermometers; (2) to assist in determining the depth at which the production casing will be set during drilling; (3) to estimate fluid pH and other chemical parameters; (4) to predict possible corrosion and scaling tendencies of the fluids; (5) as a measure of permeability and possible cold water influx into wells; (6) as a guide to field hydrology; and (7) to estimate roughly the thickness of the eroded overburden.  相似文献   

20.
Underground temperature measurements in two shallow boreholes have been carried out by the Japanese Antarctic Research Expedition at Syowa Station, East Antarctica from April, 1981 to January, 1985. Two quartz thermometers were installed in the first borehole at depths of 2 and 5 m and three were in the second one at depths of 1, 4 and 6.8 m. The mean underground temperatures in the first borehole were −8.181 and −8.843°C at depths of 2 and 5 m, and in the second one −8.242 and −8.220°C at depths of 4 and 6.8 m. As the mean air temperature at Syowa Station was −10.8°C, the underground temperature in the 2 −6.8 m depth range is about two degrees higher than the air temperature. The thermal diffusivities of the observation area are determined by the same principle of the Ångström method, using long-term underground temperature records. The thermal diffusivity around Syowa Station is established to be about two times larger than those of ordinary igneous and metamorphic rocks measured in the laboratory. The thermal conductivity of the drilled cores and surrounding outcropping rocks are also measured by the transient method with temperature conditions at +23°C and −20°C. The thermal conductivities measured in various samples at −20°C are about 7% larger than those at +23°C. Thes tendency is consistent with the results of holocrystalline rock experiments.  相似文献   