首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Seismic response of unreinforced masonry (URM) buildings is largely influenced by nonlinear behavior of spandrels, which provide coupling between piers under in‐plane lateral actions. Seismic codes do not appropriately address modeling and strength verification of spandrels, adapting procedures originally proposed for piers. Therefore, research on spandrels has received significant attention in some earthquake‐prone countries, such as Italy and New Zealand. In the last years, the authors of this paper have performed both monotonic and cyclic in‐plane lateral loading tests on full‐scale masonry walls with single opening and different spandrel types. Those tests were carried out in a static fashion and with displacement control. In this paper, experimental outcomes for two as‐built specimens are presented and compared with those obtained in the past for another as‐built specimen with a wooden lintel above the opening. In both newly tested specimens, the masonry above the opening was supported by a shallow masonry arch. In one of those specimens, a reinforced concrete (RC) bond beam was realized on top of the spandrel, resulting in a composite URM‐RC spandrel. Then, the influence of spandrel type is analyzed in terms of observed damage, force–drift curves, and their bilinear idealizations, which allowed to compare displacement ductility and overstrength of wall specimens. Furthermore, effects of rocking behavior of piers are identified, highlighting their relationship with hysteretic damping and residual drifts. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
For seismic analysis of unreinforced masonry (URM) buildings characterized by a box-like behavior, a widely accepted model is based on the equivalent frame idealization of walls. The equivalent frame model uses 1D elements to represent the vertical piers and horizontal spandrels which are connected by rigid nodes. The mechanical characterization of the elements is one of the crucial aspects to predict reasonably the building seismic behavior. Through the comparison with pseudo-static and dynamic experimental tests performed on two-story full-scale buildings, this paper validates the frame modeling in the OpenSees framework, which includes a fiber-section force-based beam element for the axial-flexural behavior, coupled with a cyclic shear-deformation phenomenological law.  相似文献   

3.
等效框架模型采用宏观模型来模拟砌体墙在平面内的抗震性能。砌体墙的墙柱和墙梁采用同时考虑轴向弯曲和剪切变形的基于力法的纤维截面进行模拟,且两者的连接视为刚性区域。轴向压缩及弯曲效应在截面纤维模型中考虑,而剪切效应由V-γ剪切恢复力模型表达,弯曲和剪切在单元层面进行耦合。通过统计和分析,确定骨架曲线的计算方法,并基于Ibarra-Krawinkler模型提出剪切恢复力模型。通过算例得出:该模型在单调加载和循环加载下的数值计算结果与试验结果均吻合较好。  相似文献   

4.
On 26 th October 2015, an Mw 7.5 earthquake struck northern Pakistan, with its epicenter located 45 km southwest of Jarm in the Hindu Kush region of Afghanistan. The earthquake resulted from reverse faulting at a depth of 210 km, resulting in 280 fatalities and substantial damage to some 109,123 buildings. Regional seismicity, characteristics of recorded strong motions, damage statistics, and building performance observations are presented. Earthquake damage was mostly constrained to seismic-deficient unreinforced masonry(URM) buildings. Typical failure modes included toppled minarets, partial or complete out of plane collapse of URM walls, diagonal shear cracking in piers, flexural cracking in spandrels, corner damage, pounding damage, and damage due to ground settlement. The majority of human loss resulted due to failure of URM walls and subsequent roof collapse. URM buildings located in rural hilly areas closer to the epicenter suffered more intense and frequent damage than urban URM buildings located farther away in larger cities.  相似文献   

5.
Seismic assessment of existing unreinforced masonry buildings represents a current challenge in structural engineering. Many historical masonry buildings in earthquake regions were not designed to withstand seismic loading; thus, these structures often do not meet the basic safety requirements recommended by current seismic codes and need to be strengthened considering the results from realistic structural analysis. This paper presents an efficient modelling strategy for representing the nonlinear response of unreinforced masonry components under in‐plane cyclic loading, which can be used for practical and accurate seismic assessment of masonry buildings. According to the proposed strategy, generic masonry perforated walls are modelled using an equivalent frame approach, where each masonry component is described utilising multi‐spring nonlinear elements connected by rigid links. When modelling piers and spandrels, nonlinear springs are placed at the two ends of the masonry element for describing the flexural behaviour and in the middle for representing the response in shear. Specific hysteretic rules allowing for degradation of stiffness and strength are then used for modelling the member response under cyclic loading. The accuracy and the significant potential of the proposed modelling approach are shown in several numerical examples, including comparisons against experimental results and the nonlinear dynamic analysis of a building structure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
The Himalayan region is one of the major seismic areas in the world. However, similar to many other seismically active locations, there are substantial numbers of unreinforced masonry(URM) buildings; the majority of which have not been designed for seismic loads. Past seismic events have shown that such buildings are highly vulnerable to earthquakes. Retrofitting of these URM buildings is an important concern in earthquake mitigation programs. Most government school buildings in rural areas of northern India are constructed of unreinforced masonry. These school buildings are socially important structures and serve as a crucial resource for rehabilitation during any disaster. The effectiveness of ferrocement(FC) to create a URM-FC composite is described in this study by estimating the performance and fragility of a URM school building before and after a retrofit. Analytical models, based on the equivalent frame method, are developed and used for nonlinear static analysis to estimate the enhancement in capacity. The capacity enhancement due to retrofitting is presented in terms of the maximum PGA sustained and damage probabilities at the expected level of earthquake hazard.  相似文献   

7.
Masonry buildings are often characterized by geometric irregularities. In many cases, such buildings meet global regularity requirements provided by seismic codes, but they are composed by irregular walls with openings. The latter are masonry walls characterized by (i) openings of different sizes, (ii) openings misaligned in the horizontal and/or vertical direction, or (iii) a variable number of openings per story. An irregular layout of openings can induce not only a nonuniform distribution of gravity loads among masonry piers but also unfavorable damage localizations resulting in a premature collapse of the wall and hence a higher seismic vulnerability. This paper is aimed at providing a simplified methodology to assess the effects of irregularities on the in‐plane seismic capacity of unreinforced masonry (URM) walls with openings. To this end, a macroelement method was developed and validated through experimental results available in the literature. The proposed methodology was based on the quantification of wall irregularities by means of geometric indices and their effects on seismic capacity of URM walls with openings through both sensitivity and regression analyses. Sensitivity analysis was based on a high number of static pushover analyses and allowed to assess variations in key seismic capacity parameters. Regression analysis let to describe each capacity parameter under varying irregularity index, providing empirical models for seismic assessment of irregular URM walls with openings. The in‐plane seismic capacity was found to be significantly affected by wall irregularities, especially in the case of openings with different heights. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
The in-plane capacity of unreinforced masonry (URM) elements may vary considerably depending on several factors, including boundary conditions, aspect ratio, vertical overburden, and masonry texture. Since the overall system resistance mainly relies on the in-plane lateral capacity of URM components when out-of-plane modes are adequately prevented, the structural assessment of URM structures could benefit from advanced numerical approaches able to account for these factors simultaneously. This paper aims at enhancing and optimising the employment of the distinct element method, currently confined to the analysis of local mechanisms of reduced-scale dry-joint blocky assemblies, with a view to simulate the experimentally observed responses of a series of URM full-scale specimens with mortared joints subjected to quasi-static in-plane cyclic loading. To this end, a mesoscale modelling approach is proposed that employs a simplified microscale modelling approach to effectively capture macroscale behaviour. Dynamic relaxation schemes are employed, in combination with time, size, and mass-scaling procedures, to decrease computational demand. A new methodology for numerically describing both unit, mortar and hybrid failure modes, also including masonry crushing due to high-compression stresses, is proposed. Empirical and homogenisation formulae for inferring the elastic properties of interface between elements are also verified, enabling the proposed approach to be applied more broadly. Using this modelling strategy, the interaction between stiffness degradation and energy dissipation rate was accounted for numerically. Although the models marginally underestimate the energy dissipation in the case of slender piers, a good agreement was obtained in terms of lateral strength, hysteretic response, and crack pattern.  相似文献   

9.
Code design of unreinforced masonry (URM) buildings is based on elastic analysis, which requires as input parameter the effective stiffness of URM walls. Eurocode estimates the effective stiffness as 50% of the gross sectional elastic stiffness, but comparisons with experimental results have shown that this may not yield accurate predictions. In this paper, 79 shear‐compression tests of modern URM walls of different masonry typologies from the literature are investigated. It shows that both the initial and the effective stiffness increase with increasing axial load ratio and that the effective‐to‐initial stiffness ratios are approximately 75% rather than the stipulated 50%. An empirical relationship that estimates the E‐modulus as a function of the axial load and the masonry compressive strength is proposed, yielding better estimates of the elastic modulus than the provision in Eurocode 6, which calculates the E‐modulus as a multiple of the compressive strength. For computing the ratio of the effective to initial stiffness, a mechanics‐based formulation is built on a recently developed analytical model for the force‐displacement response of URM walls. The model attributes the loss in stiffness to diagonal cracking and brick crushing, both of which are taken into account using mechanical considerations. The obtained results of the effective‐to‐initial stiffness ratio agree well with the test data. A sensitivity analysis using the validated model shows that the ratio of effective‐to‐initial stiffness is for most axial load ratios and wall geometries around 75%. Therefore, a modification of the fixed ratio of effective‐to‐initial stiffness from 50% to 75% is suggested.  相似文献   

10.
为研究整体开洞墙体中发生底层窗间墙破坏模式时墙体的抗震性能,对一砌体结构缩尺开洞墙体模型展开多点同步加载拟静力试验。分析了各层墙体与整片墙的破坏特征、承载与变形能力、滞回耗能特性、刚度退化规律及延性表现,重点研究了底层窗间墙位于整体结构中时其破坏过程与变形规律。试验结果表明:破坏模式相同的开洞墙体较单独墙肢抗震性能有所不同,各工况加载峰值点的上升与下降过程更为缓慢、滞回曲线更为饱满、刚度退化过程更为缓和以及延性特征更为明显。基于底层窗间墙破坏模式,依据现行规范中开洞墙体承载力计算方法所得结果与试验结果吻合,但强弱构件失效机制无从体现。试验结果可为探求砌体结构合理设计方法与实现开洞墙体延性破坏模式提供依据。  相似文献   

11.
Displacement‐based seismic assessment of buildings containing unreinforced masonry (URM) walls requires as input, among others, estimates of the in‐plane drift capacity at the considered limit states. Current codes assess the drift capacity of URM walls by means of empirical models with most codes relating the drift capacity to the failure mode and wall slenderness. Comparisons with experimental results show that such relationships result in large scatter and usually do not provide satisfactory predictions. The objective of this paper is to determine trends in drift capacities of modern URM walls from 61 experimental tests and to investigate whether analytical models could lead to more reliable estimates of the displacement capacity than the currently used empirical models. A recently developed analytical model for the prediction of the ultimate drift capacity for both shear and flexure controlled URM walls is introduced and simplified into an equation that is suitable for code implementation. The approach follows the idea of plastic hinge models for reinforced concrete or steel structures. It explicitly considers the influence of crushing due to flexural or shear failure in URM walls and takes into account the effect of kinematic and static boundary conditions on the drift capacity. Finally, the performance of the analytical model is benchmarked against the test data and other empirical formulations. It shows that it yields significantly better estimates than empirical models in current codes. The paper concludes with an investigation of the sensitivity of the ultimate drift capacity to the wall geometry, static, and kinematic boundary conditions.  相似文献   

12.
This article presents a new mechanical model for the non‐linear force–displacement response of unreinforced masonry (URM) walls developing a flexural rocking mode including their displacement capacity. The model is based on the plane‐section hypothesis and a constitutive law for the masonry with zero tensile strength and linear elastic behaviour in compression. It is assumed that only the compressed part of the wall contributes to the stiffness of the wall and therefore the model accounts for a softening of the response due the reduction of the effective area. Stress conditions for limit states are proposed that characterise the flexural failure. The new model allows therefore linking local performance levels to global displacement capacities. The limit states criteria describe the behaviour of modern URM walls with cement mortar of normal thickness and clay bricks. The model is validated through comparison of local and global engineering demand parameters with experimental results. It provides good prediction of the effective stiffness, the force capacity and the displacement capacity of URM walls at different limit states. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
14.
Displacement‐based assessment procedures require as input reliable estimates of the deformation capacity of all structural elements. For unreinforced masonry (URM) walls, current design codes specify the in‐plane deformation capacity as empirical equations of interstory drift. National codes differ with regard to the parameters that are considered in these empirical drift capacity equations, but the inhomogeneity of datasets on URM wall tests renders it difficult to validate the hypotheses with the currently available experimental data. This paper contributes to the future development of such empirical relationships by investigating the sensitivity of the drift capacity to the shear span, the aspect ratio, the axial load ratio, and the size of the wall. For this purpose, finite element models of URM walls are developed in Abaqus/Explicit and validated against a set of experimental results. The results show that the axial load ratio, the shear span, and the wall size are among the factors that influence the drift capacity the most. Empirical equations are mainly derived from test results on small walls, and the numerical results suggest that this can lead to a significant overestimation of the drift capacity for larger walls.  相似文献   

15.
Experimental tests have shown that unreinforced masonry (URM) infill walls are affected by simultaneous loading in their in-plane and out-of-plane directions, but there have been few attempts to represent this interaction in nonlinear time history analysis of reinforced concrete (RC) buildings with URM infill walls. In this paper, a recently proposed macro-model that accounts for this interaction is applied to the seismic analysis of RC framed structures with URM infill walls representative of Mediterranean building stock and practices. Two RC framed structures that are representative of low and mid-rise residential buildings are analysed with a suite of a bidirectional ground motions, scaled to three different intensities. During the analyses, the in-plane/out-of-plane interaction is monitored, showing that cracking of the infills occurs predominantly by in-plane actions, while failure occurs due to a combination of in-plane and out-of-plane displacements, with the out-of-plane component usually playing the dominant role. Along the frame height, the bottom storeys are generally the most damaged, especially where thin infill walls are used. These results are consistent with observations of damage to URM infill walls in similar buildings during recent earthquakes.  相似文献   

16.
综述了用于提高填充墙钢筋混凝土(RC)框架结构抗震性能和改善结构损伤模式的几类加固措施,从工艺、加固效果和破坏形式3个角度进行了分析。在建筑结构设计过程中,填充墙通常被视为一种典型的脆性非均质非结构构件,忽视了填充墙与RC框架之间的相互作用。地震调查报告表明,在结构遭受地震作用时,填充墙通常先于钢筋混凝土框架发生破坏,未经合理设计的填充墙RC框架结构将在地震作用下产生严重不良后果。试验结果和数值模拟分析结果证明,砌块的强度越低、砂浆的强度越高,结构的承载能力和刚度退化越慢、耗能能力越好。文中根据目前已有的建筑材料改性试验结果,从改性机理出发,分析了一系列有利于提高结构抗震性能的新型材料,并对结构的设计方案进行了探讨。  相似文献   

17.
The definition of adequate simplified models to assess the in‐plane load‐bearing capacity of masonry piers, in terms of both strength and displacement, plays a fundamental role in the seismic verification of masonry buildings. In this paper, a critical review of the most widespread strength criteria present in the literature and codes to interpret the failure modes of piers (rocking, crushing, bed joint sliding or diagonal cracking) are proposed. Models are usually based on an approximate evaluation of the stress state produced by the external forces in a few points/sections and on its assessment with reference to a limit strength domain. The aim of the review is to assess their reliability by discussing the hypotheses, which they are based on (assumed stress states; choice of reference points/sections on which to assess the pier strength; characteristics of the limit strength domain) and to verify the conditions for their proper use in practice, in terms of both stress fields (depending on the geometry of the pier, boundary conditions and applied loads) and types of masonry (i.e. regular brick masonry vs rubble stone masonry). In order to achieve these objectives, parametric nonlinear finite element analyses are performed and different experimental data available in the literature are analysed and compared. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
A hypothetical 5‐storey prototype structure with reinforced concrete (RC) frame and unreinforced masonry (URM) wall is considered. The paper focuses on a shake‐table experiment conducted on a substructure of this prototype consisting of the middle bays of its first storey. A test structure is constructed to represent the selected substructure and the relationship between demand parameters of the test structure and those of the prototype structure is established using computational modelling. The dynamic properties of the test structure are determined using a number of preliminary tests before performing the shake‐table experiments. Based on these tests and results obtained from computational modelling of the test structure, the test ground motions and the sequence of shakings are determined. The results of the shake‐table tests in terms of the global and local responses and the effects of the URM infill wall on the structural behaviour and the dynamic properties of the RC test structure are presented. Finally, the test results are compared to analytical ones obtained from further computational modelling of the test structure subjected to the measured shake‐table accelerations. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

19.
Typical low-rise masonry buildings consist of unreinforced masonry (URM) walls covered with various timber roof configurations generally supported or finished by masonry gables. Post-earthquake observations and experimental outcomes highlighted the large vulnerability of the URM gables to the development of overturning mechanisms, both because of the inertial out-of-plane excitation and the in-plane timber diaphragm deformability. This paper presents the static and dynamic experimental seismic performance of three full-scale roofs tested via quasi-static cyclic and shake table tests. Two of them were tested as part of a whole full scale one-storey and two-storey building. A single-degree-of-freedom (SDOF) numerical model is calibrated against experimental data and proposed for the analysis of this roof typology's dynamic behaviour. Several sets of analyses were conducted to assess the vulnerability of these structural components and to study the effect of the whole building's characteristics (eg, number of storeys and structural stiffness and strength) on the seismic performance of this roof typology.  相似文献   

20.
In this paper, a contribution of various types of masonry infill to the behaviour of reinforced concrete frames under lateral loads is presented. As a part of the bigger project, ten one‐bay, one‐storey reinforced concrete frames were designed according to the EC8, built in a scale 1:2.5, infilled with masonry and tested under constant vertical and cyclic lateral load. The masonry wall had various strength properties, namely, high strength hollow clay brick blocks, medium strength hollow clay brick blocks and low strength lightweight autoclaved aerated concrete blocks. There were no additional shear connectors between the masonry and frame. The results showed that the composite ‘framed wall’ structure had much higher stiffness, damping and initial strength than the bare frame structure. Masonry infill filled in the load capacity gap from very low (0.05%) to drifts when the frame took over (0.75%). The structures behaved as linear monolithic elements to drifts of 0.1%, reached the maximum lateral capacities at drift of 0.3%, maintained it to drifts of 0.75% and after that their behaviour depended on the frame. Masonry infill had severe damage at drift levels of about 0.75% but contributed to the overall system resistance to drifts of about 1%. At that drift level, the frame had only minor damage and was tested to drifts of about 2% without any loss of capacity. Improvement of the ‘infill provisions’ in the codes could be sought by taking into account the contribution of a common masonry that reduces expected damages by lowering the drift levels. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号