The modal pushover analysis (MPA) procedure, presently restricted to one horizontal component of ground motion, is extended to three‐dimensional analysis of buildings—symmetric or unsymmetric in plan—subjected to two horizontal components of ground motion, simultaneously. Also presented is a variant of this method, called the practical modal pushover analysis (PMPA) procedure, which estimates seismic demands directly from the earthquake response (or design) spectrum. Its accuracy in estimating seismic demands for very tall buildings is evaluated, demonstrating that for nonlinear systems this procedure is almost as accurate as the response spectrum analysis procedure is for linear systems. Thus, for practical applications, the PMPA procedure offers an attractive alternative whereby seismic demands can be estimated directly from the (elastic) design spectrum, thus avoiding the complications of selecting and scaling ground motions for nonlinear response history analysis. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
An Erratum has been published for this article in Earthquake Engng. Struct. Dyn. 2004; 33:1429. Based on structural dynamics theory, the modal pushover analysis (MPA) procedure retains the conceptual simplicity of current procedures with invariant force distribution, now common in structural engineering practice. The MPA procedure for estimating seismic demands is extended to unsymmetric‐plan buildings. In the MPA procedure, the seismic demand due to individual terms in the modal expansion of the effective earthquake forces is determined by non‐linear static analysis using the inertia force distribution for each mode, which for unsymmetric buildings includes two lateral forces and torque at each floor level. These ‘modal’ demands due to the first few terms of the modal expansion are then combined by the CQC rule to obtain an estimate of the total seismic demand for inelastic systems. When applied to elastic systems, the MPA procedure is equivalent to standard response spectrum analysis (RSA). The MPA estimates of seismic demand for torsionally‐stiff and torsionally‐flexible unsymmetric systems are shown to be similarly accurate as they are for the symmetric building; however, the results deteriorate for a torsionally‐similarly‐stiff unsymmetric‐plan system and the ground motion considered because (a) elastic modes are strongly coupled, and (b) roof displacement is underestimated by the CQC modal combination rule (which would also limit accuracy of RSA for linearly elastic systems). Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

3.
An Erratum has been published for this article in Earthquake Engineering and Structural Dynamics 2003; 32:1795. The recently developed modal pushover analysis (MPA) has been shown to be a significant improvement over the pushover analysis procedures currently used in structural engineering practice. None of the current invariant force distributions accounts for the contribution of higher modes—higher than the fundamental mode—to the response or for redistribution of inertial forces because of structural yielding. By including the contributions of a sufficient number of modes of vibration (generally two to three), the height‐wise distribution of responses estimated by MPA is generally similar to the ‘exact’ results from non‐linear response history analysis (RHA). Although the results of the previous research were extremely promising, only a few buildings were evaluated. The results presented below evaluate the accuracy of MPA for a wide range of buildings and ground motion ensembles. The selected structures are idealized frames of six different heights: 3, 6, 9, 12, 15, and 18 stories and five strength levels corresponding to SDF‐system ductility factor of 1, 1.5, 2, 4, and 6; each frame is analysed for 20 ground motions. Comparing the median values of storey‐drift demands determined by MPA to those obtained from non‐linear RHA shows that the MPA predicts reasonably well the changing height‐wise variation of demand with building height and SDF‐system ductility factor. Median and dispersion values of the ratios of storey‐drift demands determined by MPA and non‐linear‐RHA procedures were computed to measure the bias and dispersion of MPA estimates with the following results: (1) the bias and dispersion in the MPA procedure tend to increase for longer‐period frames and larger SDF‐system ductility factors (although these trends are not perfect); (2) the bias and dispersion in MPA estimates of seismic demands for inelastic frames are usually larger than for elastic systems; (3) the well‐known response spectrum analysis (RSA), which is equivalent to the MPA for elastic systems, consistently underestimates the response of elastic structures, e.g. up to 18% in the upper‐storey drifts of 18‐storey frames. Finally, the MPA procedure is simplified to facilitate its implementation in engineering practice—where the earthquake hazard is usually defined in terms of a median (or some other percentile) design spectrum for elastic systems—and the accuracy of this simplified procedure is documented. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

4.
The modal pushover‐based scaling (MPS) procedure, currently restricted to symmetric‐plan buildings, is extended herein to unsymmetric‐plan buildings. The accuracy of the extended MPS procedure was evaluated for a large set of three‐degree‐of‐freedom unsymmetric‐plan structures with variable stiffness and strength. The structures were subjected to nonlinear response history analysis considering sets of seven records scaled according to the MPS procedure. Structural responses were compared against the benchmark values, defined as the median values of the engineering demand parameters due to 30 unscaled records. This evaluation of the MPS procedure has led to the following conclusions: (i) the MPS procedure provided accurate estimates of median engineering demand parameter values and reduced record‐to‐record variability of the responses; and (2) the MPS procedure is found to be much superior compared to the ASCE/SEI 7‐10 scaling procedure for three‐dimensional analysis of unsymmetric‐plan buildings. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
This paper describes the three‐dimensional nonlinear analysis of six 19‐storey steel moment‐frame buildings, designed per the 1997 Uniform Building Code, under strong ground motion records from near‐source earthquakes with magnitudes in the range of 6.7–7.3. Three of these buildings possess a reentrant corner irregularity, while the remaining three possess a torsional plan irregularity. The records create drift demands of the order of 0.05 and plastic rotation demands of the order of 4–5% of a radian in the buildings with reentrant corners. These values point to performance at or near ‘Collapse Prevention’. Twisting in the torsionally sensitive buildings causes the plastic rotations on the moment frame on one face of the building (4–5% of a radian) to be as high as twice of that on the opposite face (2–3% of a radian). The asymmetric yield pattern implies a lower redundancy in the lateral force‐resisting system as the failure of the heavily loaded frame could result in a total loss of resistance to torsion. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

6.
The critical parameters that influence the nonlinear seismic response of asymmetric‐plan buildings are identified by evaluating the effects of different asymmetries that may characterize the structure of a building as well as exploring the influence of the ground motion features. First, the main findings reported in the literature on both the linear and nonlinear dynamic response of asymmetric‐plan buildings are presented. The common findings and the conflicting conclusions reached in different investigations are pointed out. Then, the results of comprehensive nonlinear dynamic analyses performed for evaluating the seismic response of systems characterized by different strength and stiffness configurations, representative of a large class of asymmetric‐plan buildings, are reported. Findings from the study indicate that the building response changes when moving from the linear to the nonlinear range, so that the seismic behavior of asymmetric‐plan buildings, apart from the source of asymmetry, can be always classified as irregular. Additionally, it was observed that as the seismic demands cause amplification of system nonlinearity with increasing earthquake intensity, the maximum displacement demand in the different resisting elements tends to be reached with the same deformed configuration of the system. The resultant of the seismic forces producing such a maximum demand is located at the center of resistance and corresponds to the collapse mechanism of the system that provides the maximum lateral strength in the exciting direction of the seismic action. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
This paper proposes bi‐directional coupled tuned mass dampers (BiCTMDs) for the seismic response control of two‐way asymmetric‐plan buildings subjected to bi‐directional ground motions. The proposed BiCTMD was developed from the three‐degree‐of‐freedom modal system, which represents the vibration mode of a two‐way asymmetric‐plan building. The performance of the proposed BiCTMD for the seismic response control of elastic two‐way asymmetric‐plan buildings was verified by investigating the reductions of the amplitudes of the associated frequency response functions. In addition, the investigation showed that the proposed BiCTMD is effective in reducing the seismic damage of inelastic asymmetric‐plan buildings. Therefore, the BiCTMD is an effective approach for the seismic response control of both elastic and inelastic two‐way asymmetric‐plan buildings. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
A generalized multi‐mode pushover analysis procedure was developed for estimating the maximum inelastic seismic response of symmetrical plan structures under earthquake ground excitations. Pushover analyses are conducted with story‐specific generalized force vectors in this procedure, with contributions from all effective modes. Generalized pushover analysis procedure is extended to three‐dimensional torsionally coupled systems in the presented study. Generalized force distributions are expressed as the combination of modal forces to simulate the instantaneous force distribution acting on the system when the interstory drift at a story reaches its maximum value during seismic response. Modal contributions to the generalized force vectors are calculated by a modal scaling rule, which is based on the complete quadratic combination. Generalized forces are applied to the mass centers of each story incrementally for producing nonlinear static response. Maximum response quantities are obtained when the individual frames attain their own target interstory drift values in each story. The developed procedure is tested on an eight‐story frame under 15 ground motions, and assessed by comparing the results obtained from nonlinear time history analysis. The method is successful in predicting the torsionally coupled inelastic response of frames responding to large interstory drift demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
In cities and urban areas, building structures located at close proximities inevitably interact under dynamic loading by direct pounding and indirectly through the underlying soil. Majority of the previous adjacent building pounding studies that have taken the structure–soil–structure interaction (SSSI) problem into account have used simple lumped mass–spring–dashpot models under plane strain conditions. In this research, the problem of SSSI‐included pounding problem of two adjacent symmetric in plan buildings resting on a soft soil profile excited by uniaxial earthquake loadings is investigated. To this end, a series of SSSI models considering one‐directional nonlinear impact elements between adjacent co‐planar stories and using a method for direct finite element modeling of 3D inelastic underlying soil volume has been developed to accurately study the problem. An advanced inelastic structural behavior parameter, the seismic damage index, has been considered in this study as the key nonlinear structural response of adjacent buildings. Based on the results of SSSI and fixed base case analyses presented herein, two main problems are investigated, namely, the minimum building separation distance for pounding prevention and seismic pounding effects on structural damage in adjacent buildings. The final results show that at least three times, the International Building Code 2009 minimum distance for building separation recommended value is required as a clear distance for adjacent symmetric buildings to prevent the occurrence of seismic pounding. At the International Building Code‐recommended distance, adjacent buildings experienced severe seismic pounding and therefore significant variations in storey shear forces and damage indices. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
This paper investigates the seismic response of multi‐storey cross‐laminated timber (CLT) buildings and its relationship with salient ground‐motion and building characteristics. Attention is given to the effects of earthquake frequency content on the inelastic deformation demands of platform CLT walled structures. The response of a set of 60 CLT buildings of varying number of storeys and panel fragmentation levels representative of a wide range of structural configurations subjected to 1656 real earthquake records is examined. It is shown that, besides salient structural parameters like panel aspect ratio, design behaviour factor, and density of joints, the frequency content of the earthquake action as characterized by its mean period has a paramount importance on the level of nonlinear deformations attained by CLT structures. Moreover, the evolution of drifts as a function of building to ground‐motion periods ratio is different for low‐ and high‐rise buildings. Accordingly, nonlinear regression models are developed for estimating the global and interstorey drifts demands on multi‐storey CLT buildings. Finally, the significance of the results is highlighted with reference to European seismic design procedures and recent assessment proposals.  相似文献   

11.
This paper presents the main results of the evaluation of residual inter‐story drift demands in typical moment‐resisting steel buildings designed accordingly to the Mexican design practice when subjected to narrow‐band earthquake ground motions. Analytical 2D‐framed models representative of the study‐case buildings were subjected to a set of 30 narrow‐band earthquake ground motions recorded on stations placed in soft‐soil sites of Mexico City, where most significant structural damage was found in buildings as a consequence of the 1985 Michoacan earthquake, and scaled to reach several levels of intensity to perform incremental dynamic analyses. Thus, results were statistically processed to obtain hazard curves of peak (maximum) and residual drift demands for each frame model. It is shown that the study‐case frames might exhibit maximum residual inter‐story drift demands in excess of 0.5%, which is perceptible for building's occupants and could cause human discomfort, for a mean annual rate of exceedance associated to peak inter‐story drift demands of about 3%, which is the limiting drift to avoid collapse prescribed in the 2004 Mexico City Seismic Design Provisions. The influence of a member's post‐yield stiffness ratio and material overstrength in the evaluation of maximum residual inter‐story drift demands is also discussed. Finally, this study introduces response transformation factors, Tp, that allow establishing residual drift limits compatible with the same mean annual rate of exceedance of peak inter‐story drift limits for future seismic design/evaluation criteria that take into account both drift demands for assessing a building's seismic performance. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Near‐fault ground motions impose large demands on structures compared to ‘ordinary’ ground motions. Recordings suggest that near‐fault ground motions with ‘forward’ directivity are characterized by a large pulse, which is mostly orientated perpendicular to the fault. This study is intended to provide quantitative knowledge on important response characteristics of elastic and inelastic frame structures subjected to near‐fault ground motions. Generic frame models are used to represent MDOF structures. Near‐fault ground motions are represented by equivalent pulses, which have a comparable effect on structural response, but whose characteristics are defined by a small number of parameters. The results demonstrate that structures with a period longer than the pulse period respond very differently from structures with a shorter period. For the former, early yielding occurs in higher stories but the high ductility demands migrate to the bottom stories as the ground motion becomes more severe. For the latter, the maximum demand always occurs in the bottom stories. Preliminary regression equations are proposed that relate the parameters of the equivalent pulse to magnitude and distance. The equivalent pulse concept is used to estimate the base shear strength required to limit story ductility demands to specific target values. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

13.
The capacity spectrum method (CSM) has established itself as one of the most used Nonlinear Static Procedures for the seismic assessment of structures, since its introduction in 1975, when it was first presented by Freeman. More recently, this procedure was implemented in the ATC40 guidelines and lately improved in the FEMA‐440 report. The first step of work addressed by this paper relates to the comparison between the two features of the CSM. In the second part, an extension of the FEMA‐440CSM version is proposed for plan‐asymmetric real RC building structures. The case studies under analysis are the SPEAR building—an irregular 3D structure representing typical old three‐storey buildings in the Mediterranean region, from the early 1970s—and two real Turkish buildings with five and eight storeys. The CSM‐ATC40, the CSM‐FEMA440 and the proposed extended CSM‐FEMA440 method are applied and the results obtained duly compared with nonlinear dynamicit timehistory analyses. For the latter, semi‐artificial ground motions are used to define the seismic action. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
The scarcity of strong ground motion records presents a challenge for making reliable performance assessments of tall buildings whose seismic design is controlled by large‐magnitude and close‐distance earthquakes. This challenge can be addressed using broadband ground‐motion simulation methods to generate records with site‐specific characteristics of large‐magnitude events. In this paper, simulated site‐specific earthquake seismograms, developed through a related project that was organized through the Southern California Earthquake Center (SCEC) Ground Motion Simulation Validation (GMSV) Technical Activity Group, are used for nonlinear response history analyses of two archetype tall buildings for sites in San Francisco, Los Angeles, and San Bernardino. The SCEC GMSV team created the seismograms using the Broadband Platform (BBP) simulations for five site‐specific earthquake scenarios. The two buildings are evaluated using nonlinear dynamic analyses under comparable record suites selected from the simulated BBP catalog and recorded motions from the NGA‐West database. The collapse risks and structural response demands (maximum story drift ratio, peak floor acceleration, and maximum story shear) under the BBP and NGA suites are compared. In general, this study finds that use of the BBP simulations resolves concerns about estimation biases in structural response analysis which are caused by ground motion scaling, unrealistic spectral shapes, and overconservative spectral variations. While there are remaining concerns that strong coherence in some kinematic fault rupture models may lead to an overestimation of velocity pulse effects in the BBP simulations, the simulations are shown to generally yield realistic pulse‐like features of near‐fault ground motion records.  相似文献   

15.
An improvement is first suggested to the modal pushover analysis (MPA) procedure for bridges initially proposed by the writers (Earthquake Engng Struct. Dyn. 2006; 35 (11):1269–1293), the key idea being that the deformed shape of the structure responding inelastically to the considered earthquake level is used in lieu of the elastic mode shape. The proposed MPA procedure is then verified by applying it to two actual bridges. The first structure is the Krystallopigi bridge, a 638 m‐long multi‐span bridge, with significant curvature in plan, unequal pier heights, and different types of pier‐to‐deck connections. The second structure is a 100 m‐long three‐span overpass bridge, typical in modern motorway construction in Europe, which, although ostensibly a regular structure, is found to exhibit a rather unsymmetric response in the transverse direction, mainly due to torsional irregularity. The bridges are assessed using response spectrum, ‘standard’ pushover (SPA), and MPA, and finally using non‐linear response history analysis (NL‐RHA) for a number of spectrum‐compatible motions. The MPA provided a good estimate of the maximum inelastic deck displacement for several earthquake intensities. The SPA on the other hand could not predict well the inelastic deck displacements of bridges wherever the contribution of the first mode to the response of the bridge was relatively low. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
An approximation approach of seismic analysis of two‐way asymmetric building systems under bi‐directional seismic ground motions is proposed. The procedures of uncoupled modal response history analysis (UMRHA) are extended to two‐way asymmetric buildings simultaneously excited by two horizontal components of ground motion. Constructing the relationships of two‐way base shears versus two‐way roof translations and base torque versus roof rotation in ADRS format for a two‐way asymmetric building, each modal pushover curve bifurcates into three curves in an inelastic state. A three‐degree‐of‐freedom (3DOF) modal stick is developed to simulate the modal pushover curve with the stated bifurcating characteristic. It requires the calculation of the synthetic earthquake and angle β. It is confirmed that the 3DOF modal stick is consistent with single‐degree‐of‐freedom modal stick in an elastic state. A two‐way asymmetric three‐story building was analyzed by UMRHA procedure incorporating the proposed 3DOF modal sticks. The analytical results are compared with those obtained from nonlinear response history analysis. It is shown that the 3DOF modal sticks are more rational and effective in dealing with the assessment of two‐way asymmetric building systems under two‐directional seismic ground motions. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

17.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
An improved linear‐elastic analysis procedure is developed in this paper as a simple approximate method for displacement‐based seismic assessment of the existing buildings. The procedure is mainly based on reducing the stiffness of structural members that are expected to respond in the inelastic range in a single global iteration step. Modal spectral displacement demands are determined from the equal displacement rule. Response predictions obtained from the proposed procedure are evaluated comparatively by using the results of benchmark nonlinear response history analysis, and both the conventional and the multi‐mode pushover analyses. In comparative evaluations, a twelve‐story RC plane frame and a six‐story unsymmetrical‐plan RC frame are employed by using 91 ground motion components. It is observed that the proposed procedure estimates the flexural deformation demands in deformation‐controlled members and the shear forces in force‐controlled members with reasonable accuracy. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
For the seismic design of a structure, horizontal ground shaking is usually considered in two perpendicular directions, even though real horizontal ground motions are complex two‐dimensional phenomena that impose different demands at different orientations. While the issue of ground motion dependence on the orientation of the recording devices has been the focus of many significant developments during the last decade, the effects of directionality on the characteristics of the structure have received less attention. This work presents a proposal to calculate the probability of exceedance of elastic spectral displacements accounting for structural typology and illustrates its relevance by means of its application to two case‐study buildings. In order to ease its implementation in seismic design codes, a simplification is developed by means of a detailed statistical analysis of the results obtained using four sets of real hazard curves. The framework presented herein is considered to represent an important contribution to the field of performance‐based earthquake engineering, permitting improved treatment of directionality effects within seismic risk design and assessment. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
Nonlinear static procedures, which relate the seismic demand of a structure to that of an equivalent single‐degree‐of‐freedom oscillator, are well‐established tools in the performance‐based earthquake engineering paradigm. Initially, such procedures made recourse to inelastic spectra derived for simple elastic–plastic bilinear oscillators, but the request for demand estimates that delve deeper into the inelastic range, motivated investigating the seismic demand of oscillators with more complex backbone curves. Meanwhile, near‐source (NS) pulse‐like ground motions have been receiving increased attention, because they can induce a distinctive type of inelastic demand. Pulse‐like NS ground motions are usually the result of rupture directivity, where seismic waves generated at different points along the rupture front arrive at a site at the same time, leading to a double‐sided velocity pulse, which delivers most of the seismic energy. Recent research has led to a methodology for incorporating this NS effect in the implementation of nonlinear static procedures. Both of the previously mentioned lines of research motivate the present study on the ductility demands imposed by pulse‐like NS ground motions on oscillators that feature pinching hysteretic behaviour with trilinear backbone curves. Incremental dynamic analysis is used considering 130 pulse‐like‐identified ground motions. Median, 16% and 84% fractile incremental dynamic analysis curves are calculated and fitted by an analytical model. Least‐squares estimates are obtained for the model parameters, which importantly include pulse period Tp. The resulting equations effectively constitute an R ? μ ? T ? Tp relation for pulse‐like NS motions. Potential applications of this result towards estimation of NS seismic demand are also briefly discussed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   