首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 74 毫秒
1.
Following several damaging earthquakes in China,research has been devoted to find the causes of the collapse of reinforced concrete(RC) building sand studying the vulnerability of existing buildings.The Chinese Code for Seismic Design of Buildings(CCSDB) has evolved over time,however,there is still reported earthquake induced damage of newly designed RC buildings.Thus,to investigate modern Chinese seismic design code,three low-,mid-and high-rise RC frames were designed according to the 2010 CCSDB and the corresponding vulnerability curves were derived by computing a probabilistic seismic demand model(PSDM).The PSDM was computed by carrying out nonlinear time history analysis using thirty ground motions obtained from the Pacific Earthquake Engineering Research Center.Finally,the PSDM was used to generate fragility curves for immediate occupancy,significant damage,and collapse prevention damage levels.Results of the vulnerability assessment indicate that the seismic demands on the three different frames designed according to the 2010 CCSDB meet the seismic requirements and are almost in the same safety level.  相似文献   

2.
According to the most modern trend, performance‐based seismic design is aimed at the evaluation of the seismic structural reliability defined as the mean annual frequency (MAF) of exceeding a threshold level of damage, i.e. a limit state. The methodology for the evaluation of the MAF of exceeding a limit state is herein applied with reference to concentrically ‘V’‐braced steel frames designed according to different criteria. In particular, two design approaches are examined. The first approach corresponds to the provisions suggested by Eurocode 8 (prEN 1998—Eurocode 8: design of structures for earthquake resistance. Part 1: general rules, seismic actions and rules for buildings), while the second approach is based on a rigorous application of capacity design criteria aiming at the control of the failure mode (J. Earthquake Eng. 2008; 12 :1246–1266; J. Earthquake Eng. 2008; 12 :728–759). The aim of the presented work is to focus on the seismic reliability obtained through these design methodologies. The probabilistic performance evaluation is based on an appropriate combination of probabilistic seismic hazard analysis, probabilistic seismic demand analysis (PSDA) and probabilistic seismic capacity analysis. Regarding PSDA, nonlinear dynamic analyses have been carried out in order to obtain the parameters describing the probability distribution laws of demand, conditioned to given values of the earthquake intensity measure. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
This study presents a seismic fragility analysis of low‐rise masonry in‐filled (MI) reinforced concrete (RC) buildings using a proposed coefficient‐based spectral acceleration method. The coefficient‐based method, without requiring any complicated finite element analysis, is a simplified procedure for assessing the spectral acceleration demand (or capacity) of buildings subjected to earthquakes. This paper begins with a calibration of the proposed coefficient‐based method for low‐rise MI RC buildings using published experimental results obtained from shaking table tests. Spectral acceleration‐based fragility curves for low‐rise MI RC buildings under various inter‐story drift limits are then constructed using the calibrated coefficient‐based method. A comparison of the experimental and estimated results indicates that the simplified coefficient‐based method can provide good approximations of the spectral accelerations at peak loads of low‐rise MI RC buildings, if a proper set of drift‐related factors and initial fundamental periods of structures are used. Moreover, the fragility curves constructed using the coefficient‐based method can provide a satisfactory vulnerability evaluation for low‐rise MI RC buildings under a given performance level. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
The assessment of seismic design codes has been the subject of intensive research work in an effort to reveal weak points that originated from the limitations in predicting with acceptable precision the response of the structures under moderate or severe earthquakes. The objective of this work is to evaluate the European seismic design code, i.e. the Eurocode 8 (EC8), when used for the design of 3D reinforced concrete buildings, versus a performance‐based design (PBD) procedure, in the framework of a multi‐objective optimization concept. The initial construction cost and the maximum interstorey drift for the 10/50 hazard level are the two objectives considered for the formulation of the multi‐objective optimization problem. The solution of such optimization problems is represented by the Pareto front curve which is the geometric locus of all Pareto optimum solutions. Limit‐state fragility curves for selected designs, taken from the Pareto front curves of the EC8 and PBD formulations, are developed for assessing the two seismic design procedures. Through this comparison it was found that a linear analysis in conjunction with the behaviour factor q of EC8 cannot capture the nonlinear behaviour of an RC structure. Consequently the corrected EC8 Pareto front curve, using the nonlinear static procedure, differs significantly with regard to the corresponding Pareto front obtained according to EC8. Furthermore, similar designs, with respect to the initial construction cost, obtained through the EC8 and PBD formulations were found to exhibit different maximum interstorey drift and limit‐state fragility curves. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
This paper presents the main results of the evaluation of residual inter‐story drift demands in typical moment‐resisting steel buildings designed accordingly to the Mexican design practice when subjected to narrow‐band earthquake ground motions. Analytical 2D‐framed models representative of the study‐case buildings were subjected to a set of 30 narrow‐band earthquake ground motions recorded on stations placed in soft‐soil sites of Mexico City, where most significant structural damage was found in buildings as a consequence of the 1985 Michoacan earthquake, and scaled to reach several levels of intensity to perform incremental dynamic analyses. Thus, results were statistically processed to obtain hazard curves of peak (maximum) and residual drift demands for each frame model. It is shown that the study‐case frames might exhibit maximum residual inter‐story drift demands in excess of 0.5%, which is perceptible for building's occupants and could cause human discomfort, for a mean annual rate of exceedance associated to peak inter‐story drift demands of about 3%, which is the limiting drift to avoid collapse prescribed in the 2004 Mexico City Seismic Design Provisions. The influence of a member's post‐yield stiffness ratio and material overstrength in the evaluation of maximum residual inter‐story drift demands is also discussed. Finally, this study introduces response transformation factors, Tp, that allow establishing residual drift limits compatible with the same mean annual rate of exceedance of peak inter‐story drift limits for future seismic design/evaluation criteria that take into account both drift demands for assessing a building's seismic performance. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
Seismic safety of low ductility structures used in Spain   总被引:1,自引:0,他引:1  
The most important aspects of the design, seismic damage evaluation and safety assessment of structures with low ductility like waffle slabs buildings or flat beams framed buildings are examined in this work. These reinforced concrete structural typologies are the most used in Spain for new buildings but many seismic codes do not recommend them in seismic areas. Their expected seismic performance and safety are evaluated herein by means of incremental non linear structural analysis (pushover analysis) and incremental dynamic analysis which provides capacity curves allowing evaluating their seismic behavior. The seismic hazard is described by means of the reduced 5% damped elastic response spectrum of the Spanish seismic design code. The most important results of the study are the fragility curves calculated for the mentioned building types, which allow obtaining the probability of different damage states of the structures as well as damage probability matrices. The results, which show high vulnerability of the studied low ductility building classes, are compared with those corresponding to ductile framed structures.  相似文献   

7.
钢筋混凝土框架结构造价与失效概率之间的近似关系研究   总被引:6,自引:1,他引:5  
本文以层间位移角作为结构性能参数,分析了钢筋混凝土框架结构层间变形能力,以及在水平地震作用下层间位移反应。考虑钢筋混凝土框架结构材料强度和几何尺寸以及地震作用的不确定性,得出了在设计基准期内结构的失效概率。同时分析了不同设计参数下结构的最小造价,在此基础上,确定了结构最小造价和失效概率之间的近似关系。目的是为采用“投资—效益“准则确定该类型结构目标性能水平提供分析依据,从而为采用基于性能抗震设计理念制定建筑结构抗震设计规范提供基础研究。本文中,结构失效概率指结构最终极限状态的失效概率。  相似文献   

8.
The seismic design of an eight‐story reinforced concrete space frame building is undertaken using a yield frequency spectra (YFS) performance‐based approach. YFS offer a visual representation of the entire range of a system's performance in terms of the mean annual frequency (MAF) of exceeding arbitrary global ductility or displacement levels versus the base shear strength. As such, the YFS framework can establish the required base shear and corresponding first‐mode period to satisfy arbitrary performance objectives for any structure that may be approximated by a single‐degree‐of‐freedom system with given yield displacement and capacity curve shape. For the eight‐story case study building, deformation checking is the governing limit state. A conventional code‐based design was performed using seismic intensities tied to the desired MAF for safety checking. Then, the YFS‐based approach was employed to redesign the resulting structure working backwards from the desired MAF of response (rather than intensity) to estimate an appropriate value of seismic intensity for use within a typical engineering design process. For this high‐seismicity and high‐importance midrise building, a stiffer system with higher base shear strength was thus derived. Moreover, performance assessment via incremental dynamic analysis showed that while the code‐design did not meet the required performance objective, the YFS‐based redesign needed only pushover analysis results to offer a near‐optimal design outcome. The rapid convergence of the method in a single design/analysis iteration emphasized its efficiency and practicability as a design aid for practical application. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

9.
Open Ground Storey(OGS) framed buildings where the ground storey is kept open without infill walls, mainly to facilitate parking, is increasing commonly in urban areas. However, vulnerability of this type of buildings has been exposed in past earthquakes. OGS buildings are conventionally designed by a bare frame analysis that ignores the stiffness of the infill walls present in the upper storeys, but doing so underestimates the inter-storey drift(ISD) and thereby the force demand in the ground storey columns. Therefore, a multiplication factor(MF) is introduced in various international codes to estimate the design forces(bending moments and shear forces) in the ground storey columns. This study focuses on the seismic performance of typical OGS buildings designed by means of MFs. The probabilistic seismic demand models, fragility curves, reliability and cost indices for various frame models including bare frames and fully infilled frames are developed. It is found that the MF scheme suggested by the Israel code is better than other international codes in terms of reliability and cost.  相似文献   

10.
The objectives of the Istanbul Seismic Risk Mitigation and Emergency Preparedness Project are to improve Istanbul’s preparedness for a potential earthquake. Within this framework “Risk Assessment of Cultural Heritage Buildings” was designed to address the vulnerability of cultural assets, specifically buildings with global cultural heritage value. One of the components of the project was the vulnerability and risk assessment of 170 historical buildings. After a discussion of the choice of the most appropriate earthquake scenario, the methodology used for assessing the effects of local site conditions on the seismic performance of selected cultural heritage buildings is presented. The purpose is to estimate the earthquake characteristics on the ground surface based on the earthquake characteristics on the engineering bedrock outcrop obtained from the probabilistic and deterministic hazard studies. The site specific elastic design spectra for each site are then further manipulated to obtain site specific non linear displacement spectra, so that these can be directly compared with capacity curves for the buildings obtained by using plasticity based limit state analysis. The procedure for obtaining the capacity curves is described and the choice of the most appropriate level of ductility and the equivalent reduction coefficient are discussed. A procedure to evaluate performance points and to define safety factors based on lateral acceleration, drift or expected damage level, is presented. The process of arriving at a risk evaluation and hence recommendation for strengthening or otherwise, is finally highlighted with respect to two comparable case studies.  相似文献   

11.
由于承重结构构件分布不均匀,导致高层建筑框架承重构件间的距离不相等。在地震时,这种不规则分布可能引起加速度共振效应,从而导致建筑失稳。为此,以地震动强度、地震动速度峰值、最大层间位移角为参数指标,分析高层建筑的极限状态,提出基于增量动力地震易损性分析的高层结构抗震加固研究。以某实际工程为试验对象,运用ABAQUS软件构造高层建筑框架结构三维模型,选取多条地震波以及符合场地条件的地震动记录进行验证,绘制地震易损性曲线。结果表明:在高层建筑框架结构中安装阻尼器,可增强结构中各构件的承载力,改善高层建筑抗震性能;增加钢板厚度可提高结构抗震水平,降低极限状态下框架结构IO、LS与CP的超越概率;提高混凝土强度,可改善框架结构抗倒塌性能。高层结构完成抗震加固后,抗震能力由0.91提升至1.01。由此证明,以增量动力分析得到的结构易损性为基础,对建筑易损性较大的地方进行加固、完善,能够改善高层建筑框架结构地震易损性,减少地震灾害损失。  相似文献   

12.
The seismic performance of three‐ and six‐story buildings with fluidic self‐centering system is probabilistically assessed. The fluidic self‐centering systems consist of devices that are based on the technology of fluid viscous dampers but built in a way that pressurization of the devices results in preload that is explored to reduce or eliminate residual drift. The design of these buildings followed a procedure that parallels the design for structures with damping systems in ASCE 7 but modified to include the preload effect. Reference conventional buildings were also designed per ASCE 7 for comparison. These buildings were then analyzed to examine and compare their seismic collapse resistance and residual drift, where the residual drift limits of 0.2, 0.5, 1.0 and 2.0% of story height were selected as important thresholds. The study further calculated the mean annual frequency of collapse and corresponding exceedance probability over 50 years, and the mean annual frequency of exceeding the threshold residual story drift limits and the corresponding exceedance probability over 50 years. Variations in the design procedures by considering increased displacement capacity or damping or preload of the devices, different types of damping, increased ultimate strength of the self‐centering device–brace systems and increased frame strength were considered. It was found that increasing either the ultimate force capacity of the self‐centering device–brace system or the frame strength results in important improvements in the collapse resistance and in minimizing residual drift, whereas the variation of other design parameters has minor effects. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
Performance-Based Seismic Design is now widely recognized as the pre-eminent seismic design and assessment methodology for building structures. In recognition of this, seismic codes may require that buildings achieve multiple performance objectives such as withstanding moderate, yet frequently occurring earthquakes with minimal structural and non-structural damage, while withstanding severe, but rare earthquakes without collapse and loss of life. These objectives are presumed to be satisfied by some codes if the force-based design procedures are followed. This paper investigates the efficacy of the Eurocode 8 force-based design provisions with respect to RC frame building design and expected seismic performance. Four, eight, and 16-storey moment frame buildings were designed and analyzed using the code modal response spectrum analysis provisions. Non-linear time-history analyses were subsequently performed to determine the simulated seismic response of the structures and to validate the Eurocode 8 force-based designs. The results indicate the design of flexural members in medium-to-long period structures is not significantly influenced by the choice of effective member stiffness; however, calculated interstorey drift demands are significantly affected. This finding was primarily attributed to the code’s enforcement of a minimum spectral ordinate on the design spectrum. Furthermore, design storey forces and interstorey drift demand estimates (and therefore damage), obtained by application of the code force-based design procedure varied substantially from those found through non-linear time-history analysis. Overall, the results suggest that though the Eurocode 8 may yield life-safe designs, the seismic performance of frame buildings of the same type and ductility class can be highly non-uniform.  相似文献   

14.
Studies of recorded ground motions and simulations have shown that deep sedimentary basins can greatly increase the intensity of earthquake ground motions within a period range of approximately 1–4 s, but the economic impacts of basin effects are uncertain. This paper estimates key economic indicators of seismic performance, expressed in terms of earthquake‐induced repair costs, using empirical and simulated seismic hazard characterizations that account for the effects of basins. The methodology used is general, but the estimates are made for a series of eight‐ to 24‐story residential reinforced concrete shear wall archetype buildings in Seattle, WA, whose design neglects basin effects. All buildings are designed to comply with code‐minimum requirements (i.e., reference archetypes), as well as a series of design enhancements, which include (a) increasing design forces, (b) decreasing drift limits, and (c) a combination of these strategies. As an additional reference point, a performance‐based design is also assessed. The performance of the archetype buildings is evaluated for the seismic hazard level in Seattle according to the 2018 National Seismic Hazard Model (2018 NSHM), which explicitly considers basin effects. Inclusion of basin effects results in an average threefold increase in annualized losses for all archetypes. Incorporating physics‐based ground motion simulations to represent the large‐magnitude Cascadia subduction interface earthquake contribution to the hazard results in a further increase of 22% relative to the 2018 NSHM. The most effective of the design strategies considered combines a 25% increase in strength with a reduction in drift limits to 1.5%.  相似文献   

15.
This paper presents, within the performance‐based earthquake engineering framework, a comprehensive probabilistic seismic loss estimation method that accounts for main sources of uncertainty related to hazard, vulnerability, and loss. The loss assessment rigorously integrates multiple engineering demand parameters (maximum and residual inter‐story drift ratio and peak floor acceleration) with consideration of mainshock–aftershock sequences. A 4‐story non‐ductile reinforced concrete building located in Victoria, British Colombia, Canada, is considered as a case study. For 100 mainshock and mainshock–aftershock earthquake records, incremental dynamic analysis is performed, and the three engineering demand parameters are fitted with a probability distribution and corresponding dependence computed. Finally, with consideration of different demolition limit states, loss assessment is performed. From the results, it can be shown that when seismic vulnerability models are integrated with seismic hazard, the aftershock effects are relatively minor in terms of overall seismic loss (1–4% increase). Moreover, demolition limit state parameters, uncertainties of collapse fragility, and non‐collapse seismic demand prediction models have showed significant contribution to the loss assessment. The seismic loss curves for the reference case and for cases with the varied parameters can differ by as large as about 150%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
Building period formulas in seismic design code are evaluated with over 800 apparent building periods from 191 building stations and 67 earthquake events. The evaluation is carried out with the formulas in ASCE 7‐05 for steel and RC moment‐resisting frames, shear wall buildings, braced frames, and other structural types. Qualitative comparison of measured periods and periods calculated from the code formulas shows that the formula for steel moment‐resisting frames generally predicts well the lower bound of the measured periods for all building heights. But the differences between the periods from code formula and measured periods of low‐ to‐medium rise buildings are relatively high. In addition, the periods of essential buildings designed with the importance factor are about 40% shorter than the periods of non‐essential buildings. The code formula for RC moment‐resisting frames describes well the lower bound of measured periods. The formula for braced frames accurately predicts the lower bound periods of low‐to‐medium rise buildings. The formula for shear wall buildings overestimates periods for all building heights. For buildings that are classified as other structural types, the measured building periods can be much shorter than the periods calculated with the code formula. Based on these observations, it is suggested to use Cr factor of 0.015 for shear walls and other structural types. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
This paper presents a simplified method of evaluating the seismic performance of buildings. The proposed method is based on the transformation of a multiple degree of freedom (MDOF) system to an equivalent single degree of freedom (SDOF) system using a simple and intuitive process. The proposed method is intended for evaluating the seismic performance of the buildings at the intermediate stages in design, while a rigorous method would be applied to the final design. The performance of the method is evaluated using a series of buildings which are assumed to be located in Victoria in western Canada, and designed based on the upcoming version of the National Building Code of Canada which is due to be published in 2005. To resist lateral loads, some of these buildings contain reinforced concrete moment resisting frames,while others contain reinforced concrete shear walls. Each building model has been subjected to a set of site-specific seismic spectrum compatible ground motion records, and the response has been determined using the proposed method and the general method for MDOF systems. The results from the study indicate that the proposed method can serve as a useful tool for evaluation of seismic performance of buildings, and carrying out performance based design.  相似文献   

18.
The potential of post-tensioned self-centering moment-resisting frames (SC-MRFs) and viscous dampers to reduce the collapse risk and improve the residual drift performance of steel buildings in near-fault regions is evaluated. For this purpose, a prototype steel building is designed using different seismic-resistant frames, i.e.: moment-resisting frames (MRFs); MRFs with viscous dampers; SC-MRFs; and SC-MRFs with viscous dampers. The frames are modeled in OpenSees where material and geometrical nonlinearities are taken into account as well as stiffness and strength deterioration. A database of 91 near-fault, pulse-like ground motions with varying pulse periods is used to conduct incremental dynamic analysis (IDA), in which each ground motion is scaled until collapse occurs. The probability of collapse and the probability of exceeding different residual story drift threshold values are calculated as a function of the ground motion intensity and the period of the velocity pulse. The results of IDA are then combined with probabilistic seismic hazard analysis models that account for near-fault directivity to assess and compare the collapse risk and the residual drift performance of the frames. The paper highlights the benefit of combining the post-tensioning and supplemental viscous damping technologies in the near-source. In particular, the SC-MRF with viscous dampers is found to achieve significant reductions in collapse risk and probability of exceedance of residual story drift threshold values compared to the MRF.  相似文献   

19.
For the first time after the finalisation of the European Norm for seismic design of buildings (Eurocode 8 – EC8),the performance of RC buildings designed with this code is evaluated through systematic nonlinear analyses. Regular 4-, 8- or 12-storey RC frames are designed for a PGA of 0.2 or 0.4 g and to one of the three alternative ductility classes in EC8. As the Eurocodes are meant to replace soon existing national codes, design and performance is also compared to that of similar frames designed with the 2000 Greek national codes. The performance of alternative designs under the life-safety (475 years) and the damage limitation (95 years) earthquakes is evaluated through nonlinear seismic response analyses. The large difference in material quantities and detailing of the alternative designs does not translate into large differences in performance. Design for either Ductility Class High (H) or Medium (M) of EC8 is much more cost-effective than design for Ductility Class Low (L), even in moderate seismicity. It is also much more cost-effective than design to the 2000 Greek national codes.  相似文献   

20.
Post-earthquake surveys indicate that losses come from non-structural damage more than from structural damage. Current performance-based design would prevent excessive non-structural damage as well, but the effectiveness of relevant code provisions has not been assessed in depth. This study investigates the drift-sensitive non-structural damage to reinforced concrete frame buildings complying with the European seismic code. Damage to non-structural unreinforced masonry infill walls in contact with the frame is quantified in terms of numerical fragility curves with the same quantities considered in the design: the peak ground acceleration measures the seismic intensity; the peak value of the interstorey drift ratio is the damage index. The methodology for the fragility computation is described in detail. Peculiar is the use of probabilistic parameters of the drift capacity coupled to the fuzziness in the damage state. The drift demand is estimated by member-by-member modelling of typical frame structures and non-linear time–history analyses under spectrum-compatible artificial accelerograms. The kind of the infills and their modelling, the number of storeys, the ground type, and the ductility class are covered. Modelling the infills results to be essential. Any code-compliant verification is on the safe side, but the margin appears to be inconsistent among the frames under consideration. Furthermore, there is one case where occupancy appears to be not ensured despite the code verification is satisfied. The effect of the number of storeys may be misrepresented. The ductility class may be unimportant, however the damage seems to be correlated with the likely strength.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号