This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Optimum isolation damping for minimum acceleration response of base-isolated structures subjected to stationary random excitation is investigated. Three linear models are considered to account for the energy dissipation mechanism of the isolation system: a Kelvin element, a linear hysteretic element and a standard solid linear element, commonly used viscoelastic models for isolation systems comprising natural rubber bearings and viscous dampers. The criterion selected for optimality is the minimization of the mean-square floor acceleration response. The effects of the frequency content of the excitation and superstructure properties on the optimum damping and on the mean-square acceleration response are addressed. The study basically shows that the attainable reduction in the floor acceleration largely depends on the energy dissipation mechanism assumed for the isolation system as well as on the frequency content of the ground acceleration process. Special care should be taken in accurately modelling the mechanical behaviour of the energy dissipation devices.  相似文献   

3.
Numerical simulations are performed to assess the effects of near-fault ground motions on base-isolated buildings that consist of either lead-rubber (LRB) or friction-pendulum system (FPS) bearings in addition to supplemented viscous dampers. While LRB and FPS isolation systems have been applied for a number of years, the addition of supplemental damping devices is being currently considered for strong ground motions to reduce the isolator displacements. However, the main problem in this case is that the addition of damping may increase both internal deformation and absolute accelerations of the superstructure and thus may defeat many of the gains for which base isolation is intended. In the present paper, a detailed and systematic investigation on the performance of LRB and FPS isolation systems, provided with supplemental viscous damping under the effect of near-fault ground motions, has been carried out by using commercial finite element software.  相似文献   

4.
A series of large‐scale dynamic tests was conducted on a passively controlled five‐story steel building on the E‐Defense shaking table facility in Japan to accumulate knowledge of realistic seismic behavior of passively controlled structures. The specimen was tested by repeatedly inserting and replacing each of four damper types, that is, the buckling restrained braces, viscous dampers, oil dampers, and viscoelastic dampers. Finally, the bare steel moment frame was tested after removing all dampers. A variety of excitations was applied to the specimen, including white noise, various levels of seismic motion, and shaker excitation. System identification was implemented to extract dynamic properties of the specimen from the recorded floor acceleration data. Damping characteristics of the specimen were identified. In addition, simplified estimations of the supplemental damping ratios provided by added dampers were presented to provide insight into understanding the damping characteristics of the specimen. It is shown that damping ratios for the specimen equipped with velocity‐dependent dampers decreased obviously with the increasing order of modes, exhibiting frequency dependency. Damping ratios for the specimen equipped with oil and viscoelastic dampers remained constant regardless of vibration amplitudes, whereas those for the specimen equipped with viscous dampers increased obviously with an increase in vibration amplitudes because of the viscosity nonlinearity of the dampers. In very small‐amplitude vibrations, viscous and oil dampers provided much lower supplemental damping than the standard, whereas viscoelastic dampers could be very efficient. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
This paper focuses on slab vibration and a horizontal‐vertical coupling effect observed in a full‐scale 5‐story moment frame test bed building in 2 configurations: isolated with a hybrid combination of lead‐rubber bearings and cross‐linear (rolling) bearings, and fixed at the base. Median peak slab vibrations were amplified—relative to the peak vertical shake table accelerations—by factors ranging from 2 at the second floor to 7 at the roof, and horizontal floor accelerations were significantly amplified during 3D (combined horizontal and vertical) motions compared with 2D (horizontal only) motions of comparable input intensity. The experimentally observed slab accelerations and the horizontal‐vertical coupling effect were simulated through a 3D model of the specimen using standard software and modeling assumptions. The floor system was modeled with frame elements for beams/girders and shell elements for floor slabs; the insertion point method with end joint offsets was used to represent the floor system composite behavior, and floor mass was finely distributed through element discretization. The coupling behavior was partially attributed to the asymmetry of the building that was intensified by asymmetrically configured supplemental mass at the roof. Horizontal‐vertical coupled modes were identified through modal analysis and verified with evaluation of floor spectral peaks.  相似文献   

6.
In this study, the multi‐intensity seismic response of code‐designed conventional and base‐isolated steel frame buildings is evaluated using nonlinear response history analysis. The results of hazard and structural response analysis for three‐story braced‐frame buildings are presented in this paper. Three‐dimensional models for both buildings are created and seismic response is assessed for three scenario earthquakes. The response history analysis results indicate that the design objectives are met and the performance of the isolated building is superior to the conventional building in the design event. For the Maximum Considered Earthquake, isolation leads to reductions in story drifts and floor accelerations relative to the conventional building. However, the extremely high displacement demands of the isolation system could not be accommodated under normal circumstances, and creative approaches should be developed to control displacements in the MCE. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
An experimental investigation on a base isolation system incorporating stainless steel–Teflon bearings as sliders, and pressurized fluid viscous spring dampers, is presented in this paper. In the system examined, dampers are connected to the base floor of an isolated building to provide the desired passive control of response in the superstructure, as well as to guarantee that it re‐centres completely after the termination of a seismic action. Two types of experiments were conducted: sinusoidal and random cyclic tests, and a pseudodynamic test in ‘substructured’ configuration. The cyclic tests were aimed at characterizing what follows: the hysteretic and strain‐rate‐dependent response of the considered highly non‐linear spring dampers; the normal pressure‐ and strain‐rate‐dependent frictional behaviour of steel–Teflon bearings, manufactured in compliance with the latest standards for this class of sliders; and the combined response of their assembly. The pseudodynamic test simulated the installation of the protection system at the base of a 2:3‐scale three‐storey steel frame structure, already tested in unprotected conditions by an earlier experimental campaign. Among other findings, the results of the performed tests, as well as of relevant mechanical interpretation and numerical simulation analyses, confirmed the linear additive combination of the dissipative actions of spring dampers and sliders in this mixed installation, and the high protective performance of the considered base isolation/supplemental damping system in a realistic earthquake simulation. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

8.
This paper presents a direct displacement-based design procedure for seismic retrofit of existing buildings using nonlinear viscous dampers according to equivalent linear systems. Unlike conventional methods, the equivalent linear viscous damping provided by the nonlinear viscous dampers is derived based on the assumption that the average energy dissipated between the linear and the nonlinear viscous dampers is equal. Also, the equivalent period and viscous damping for the equivalent linear systems which are used for representing the behavior of bare frames (the buildings without dampers) are derived from the concept of average storage energy and average dissipated energy, respectively. It is shown from nonlinear time-history analyses that the nonlinear action of the retrofitted structures can be reasonably captured by the presented direct displacement-based procedure.  相似文献   

9.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
In the current code requirements for the design of base isolation systems for buildings located at near-fault sites, the design engineer is faced with very large design displacements for the isolators. To reduce these displacements, supplementary dampers are often prescribed. These dampers reduce displacements, but at the expense of significant increases in interstorey drifts and floor accelerations in the superstructure. An elementary analysis based on a simple model of an isolated structure is used to demonstrate this dilemma. The model is linear and is based on modal analysis, but includes the modal coupling terms caused by high levels of damping in the isolation system. The equations are solved by a method that avoids complex modal analysis. Estimates of the important response quantities are obtained by the response spectrum method. It is shown that as the damping in the isolation system increases, the contribution of the modal coupling terms due to isolator damping in response to the superstructure becomes the dominant term. The isolator displacement and structural base shear may be reduced, but the floor accelerations and interstorey drift are increased. The results show that the use of supplemental dampers in seismic isolation is a misplaced effort and alternative strategies to solve the problem are suggested. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

11.
Viscoelastic–plastic (VEP) dampers are hybrid passive damping devices that combine the advantages of viscoelastic and hysteretic damping. This paper first formulates a semi‐analytical procedure for predicting the peak response of nonlinear SDOF systems equipped with VEP dampers, which forms the basis for the generation of Performance Spectra that can then be used for direct performance assessment and optimization of VEP damped structures. This procedure is first verified against extensive nonlinear time‐history analyses based on a Kelvin viscoelastic model of the dampers, and then against a more advanced evolutionary model that is calibrated to characterization tests of VEP damper specimens built from commercially available viscoelastic damping devices, and an adjustable friction device. The results show that the proposed procedure is sufficiently accurate for predicting the response of VEP systems without iterative dynamic analysis for preliminary design purposes. A design method based on the Performance Spectra framework is then proposed for systems equipped with passive VEP dampers and is applied to enhance the seismic response of a six‐storey steel moment frame. The numerical simulation results on the damped structure confirm the use of the Performance Spectra as a convenient and accurate platform for the optimization of VEP systems, particularly during the initial design stage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
A design strategy for control of buildings experiencing inelastic deformations during seismic response is formulated. The strategy is using weakened, and/or softened, elements in a structural system while adding passive energy dissipation devices (e.g. viscous fluid devices, etc.) in order to control simultaneously accelerations and deformations response during seismic events. A design methodology is developed to determine the locations and the magnitude of weakening and/or softening of structural elements and the added damping while insuring structural stability. A two‐stage design procedure is suggested: (i) first using a nonlinear active control algorithm, to determine the new structural parameters while insuring stability, then (ii) determine the properties of equivalent structural parameters of passive system, which can be implemented by removing or weakening some structural elements, or connections, and by addition of energy dissipation systems. Passive dampers and weakened elements are designed using an optimization algorithm to obtain a response as close as possible to an actively controlled system. A case study of a five‐story building subjected to El Centro ground motion, as well as to an ensemble of simulated ground motions, is presented to illustrate the procedure. The results show that following the design strategy, a control of both peak inter‐story drifts and total accelerations can be obtained. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
The self‐centering energy dissipative (SCED) brace is a new steel bracing member that provides both damping to the structure and a re‐centering capability. The goal of this study was to confirm the behavior of SCED braces within complete structural systems and to confirm the ability to model these systems with both a state‐of‐the‐art computer model as well as a simplified model that would be useful to practicing engineers. To these ends, a three‐story SCED‐braced frame was designed and constructed for testing on a shake table. Two concurrent computer models of the entire frame were constructed: one using the opensees nonlinear dynamic modeling software, and a simplified model using the commercial structural analysis software sap2000 . The frame specimen was subjected to 12 significant earthquakes without any adjustment or modification between the tests. The SCED braces prevented residual drifts in the frame, as designed, and did not show any significant degradation due to wear. Both numerical models were able to predict the drifts, story shears, and column forces well. Peak story accelerations were overestimated in the models; this effect was found to be caused by the absence of transitions at stiffness changes in the hysteretic model of the braces. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents real‐time hybrid earthquake simulation (RTHS) on a large‐scale steel structure with nonlinear viscous dampers. The test structure includes a three‐story, single‐bay moment‐resisting frame (MRF), a three‐story, single‐bay frame with a nonlinear viscous damper and associated bracing in each story (called damped braced frame (DBF)), and gravity load system with associated seismic mass and gravity loads. To achieve the accurate RTHS results presented in this paper, several factors were considered comprehensively: (1) different arrangements of substructures for the RTHS; (2) dynamic characteristics of the test setup; (3) accurate integration of the equations of motion; (4) continuous movement of the servo‐controlled hydraulic actuators; (5) appropriate feedback signals to control the RTHS; and (6) adaptive compensation for potential control errors. Unlike most previous RTHS studies, where the actuator stroke was used as the feedback to control the RTHS, the present study uses the measured displacements of the experimental substructure as the feedback for the RTHS, to enable accurate displacements to be imposed on the experimental substructure. This improvement in approach was needed because of compliance and other dynamic characteristics of the test setup, which will be present in most large‐scale RTHS. RTHS with ground motions at the design basis earthquake and maximum considered earthquake levels were successfully performed, resulting in significant nonlinear response of the test structure, which makes accurate RTHS more challenging. Two phases of RTHS were conducted: in the first phase, the DBF is the experimental substructure, and in the second phase, the DBF together with the MRF is the experimental substructure. The results from the two phases of RTHS are presented and compared with numerical simulation results. An evaluation of the results shows that the RTHS approach used in this study provides a realistic and accurate simulation of the seismic response of a large‐scale structure with rate‐dependent energy dissipating devices. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
The seismic performance of three‐ and six‐story buildings with fluidic self‐centering system is probabilistically assessed. The fluidic self‐centering systems consist of devices that are based on the technology of fluid viscous dampers but built in a way that pressurization of the devices results in preload that is explored to reduce or eliminate residual drift. The design of these buildings followed a procedure that parallels the design for structures with damping systems in ASCE 7 but modified to include the preload effect. Reference conventional buildings were also designed per ASCE 7 for comparison. These buildings were then analyzed to examine and compare their seismic collapse resistance and residual drift, where the residual drift limits of 0.2, 0.5, 1.0 and 2.0% of story height were selected as important thresholds. The study further calculated the mean annual frequency of collapse and corresponding exceedance probability over 50 years, and the mean annual frequency of exceeding the threshold residual story drift limits and the corresponding exceedance probability over 50 years. Variations in the design procedures by considering increased displacement capacity or damping or preload of the devices, different types of damping, increased ultimate strength of the self‐centering device–brace systems and increased frame strength were considered. It was found that increasing either the ultimate force capacity of the self‐centering device–brace system or the frame strength results in important improvements in the collapse resistance and in minimizing residual drift, whereas the variation of other design parameters has minor effects. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
大底盘多塔楼结构的混合隔震控制   总被引:2,自引:0,他引:2  
结合某实际工程,针对大底盘多塔楼结构提出混合隔震的控制策略,即对大底盘上的一栋或多栋塔楼采用隔震技术,并在隔震层附设一定数量的被动、主动或半主动的减震控制装置。建立了这种大底盘多塔楼结构混合隔震控制体系的运动方程,方程中各塔楼与下部结构及隔震层之间的刚度解耦,并考虑了隔震层的非线性。研究中比较了被动非线性粘滞阻尼器,半主动变孔隙阻尼器与理想主动控制时的减震控制效果。结果表明,这种混合隔震体系可以有效地减小上部塔楼与下部结构的地震反应,提高大底盘多塔楼结构的抗震安全性,取得明显的经济和社会效益。半主动变孔隙阻尼器可以极好地追踪理想主动控制力,取得与理想主动控制相近的减震控制效果。被动非线性粘滞阻尼器也能取得较好的减震效果,且易于维护,经济性较好,从工程应用的角度来看更为现实可行,具有较好的应用推广价值。  相似文献   

17.
Base‐isolation is regarded as one of the most effective methods for protecting the structural and nonstructural building elements from design level horizontal earthquake ground shaking. However, base‐isolation as currently practiced does not offer unlimited protection for these buildings, especially when the ground shaking includes a strong vertical component. The vulnerability of nonstructural systems in a base‐isolated building was made evident during recent shake table testing of a full‐scale five‐story base‐isolated steel moment frame where nonstructural system damage was observed following tests including vertical excitation. Past research efforts have attempted to achieve 3D isolation of buildings and nuclear structures by concentrating both the horizontal and vertical flexibility at the base of the building that are either quite limited or not economically viable. An approach whereby the vertical flexibility is distributed up the height of the building superstructure to passively reduce vertical acceleration demands in base‐isolated buildings is presented. The vertical flexibility is achieved by placing laterally restrained elastomeric ‘column’ bearings at one or more floor levels along the height of the building. To broadly investigate the efficacy of the vertically distributed flexibility concept and the trade‐off between mitigation and cost, a multi‐objective optimization study was conducted considering 3‐story, 9‐story, and 20‐story archetype buildings that aimed to minimize the median peak vertical floor acceleration demands and to minimize the direct cost of column bearings. Based on the results of the optimization study, a practical rule for determining the number of levels and locations of column bearings is proposed and evaluated. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A design procedure for seismic retrofitting of concentrically and eccentrically braced frame buildings is proposed and validated in this paper. Rocking walls are added to the existing system to ensure an almost uniform distribution of the interstorey displacement in elevation. To achieve direct and efficient control over the seismic performance, the design procedure is founded on the displacement‐based approach and makes use of overdamped elastic response spectra. The top displacement capacity of the building is evaluated based on a rigid lateral deformed configuration of the structure and on the ductility capacity of the dissipative members of the braced frames. The equivalent viscous damping ratio of the braced structure with rocking walls is calculated based on semi‐empirical relationships specifically calibrated in this paper for concentrically and eccentrically braced frames. If the equivalent viscous damping ratio of the structure is lower than the required equivalent viscous damping ratio, viscous dampers are added and arranged between the rocking walls and adjacent reaction columns. The design internal forces of the rocking walls are evaluated considering the contributions of more than one mode of vibration. The proposed design procedure is applied to a large set of archetype braced frame buildings and its effectiveness verified by nonlinear dynamic analysis.  相似文献   

19.
结构附加粘滞阻尼器的抗震设计   总被引:2,自引:0,他引:2  
本文结合抗震设计规范反应谱,给出了一个附加非线性流体粘滞阻尼器结构的抗震设计方法。研究了非线性阻尼器的力学特性,引入了非线性流体阻尼器的等效线性阻尼比,给出了计算最大加速度时刻附加非线性流体阻尼器结构反应的荷载组合系数,提出了按阻尼力的水平力分量与楼层剪力成正比的原则分配阻尼器阻尼系数的方法。同时给出了基于抗震规范设计反应谱附加非线性阻尼器结构的设计流程,通过一个算例说明了使用该方法设计附加非线性粘滞阻尼器结构的全过程。算例分析表明,这种设计方法适合于手算,便于设计人员掌握,在初步设计阶段可以快速、有效地设计满足给定性能水平的附加非线性流体阻尼器体系。  相似文献   

20.
The potential of post‐tensioned self‐centering moment‐resisting frames (SC‐MRFs) and viscous dampers to reduce the economic seismic losses in steel buildings is evaluated. The evaluation is based on a prototype steel building designed using four different seismic‐resistant frames: (i) conventional moment resisting frames (MRFs); (ii) MRFs with viscous dampers; (iii) SC‐MRFs; or (iv) SC‐MRFs with viscous dampers. All frames are designed according to Eurocode 8 and have the same column/beam cross sections and similar periods of vibration. Viscous dampers are designed to reduce the peak story drift under the design basis earthquake (DBE) from 1.8% to 1.2%. Losses are estimated by developing vulnerability functions according to the FEMA P‐58 methodology, which considers uncertainties in earthquake ground motion, structural response, and repair costs. Both the probability of collapse and the probability of demolition because of excessive residual story drifts are taken into account. Incremental dynamic analyses are conducted using models capable to simulate all limit states up to collapse. A parametric study on the effect of the residual story drift threshold beyond which is less expensive to rebuild a structure than to repair is also conducted. It is shown that viscous dampers are more effective than post‐tensioning for seismic intensities equal or lower than the maximum considered earthquake (MCE). Post‐tensioning is effective in reducing repair costs only for seismic intensities higher than the DBE. The paper also highlights the effectiveness of combining post‐tensioning and supplemental viscous damping by showing that the SC‐MRF with viscous dampers achieves significant repair cost reductions compared to the conventional MRF. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   