首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
The seismic behavior of plane moment‐resisting frames (MRFs) consisting of I steel beams and concrete‐filled steel tube (CFT) columns is investigated in this study. More specifically, the effect of modeling details of each individual component of CFT‐MRFs, such as the composite CFT columns, the beam‐column connections, the panel zones, and the steel I beams on their seismic behavior, is studied through comparisons against available experimental results. Then, fragility curves are constructed for three typical CFT‐MRFs, designed according to European codes, for various levels of modeling sophistication through nonlinear time‐history analyses. On the basis of these fragility curves, one can select the appropriate modeling level of sophistication that can lead to the desired seismic behavior for a given seismic intensity. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
A refined component model is proposed to predict the inelastic monotonic response of exterior and interior beam‐to‐column joints for partial‐strength composite steel–concrete moment‐resisting frames. The joint typology is designed to exhibit ductile seismic response through plastic deformation developing simultaneously in the column web panel in shear, the bolted end‐plate connection, the column flanges in bending and the steel reinforcing bars in tension. The model can handle the large inelastic deformations consistent with high ductility moment‐resisting frames. Slip response between the concrete slab and the beams was taken into account. A fibre representation was adopted for the concrete slab to accurately capture the non‐uniform stress distribution and progressive crushing of the concrete at the interface between the concrete slab and the column flange. The model is validated against results from full‐scale subassemblages monotonic physical tests performed at the University of Pisa, Italy. A parametric study is presented to illustrate the capabilities of the model and the behaviour of the joints examined. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

3.
4.
An existing two‐dimensional macroelement for reinforced concrete beam–column joints is extended to a three‐dimensional macroelement. The three‐dimensional macroelement for beam–column joints consists of six rigid interface plates and uniaxial springs for concrete, steel, and bond–slip, which model the inside of a beam–column joint. The mechanical models for the materials and the stiffness equation for the springs are also presented. To validate the model, we used test results from three slab–beam–column sub‐assemblages subjected to bi‐lateral cyclic load. It is revealed that the new joint model is capable of capturing the strength of beam–column joints and the bidirectional interaction in joint shear response, including the concentration of damage in the beam–column joint, the pinching nature in hysteretic behavior, the stiffness degradation, and strength deterioration resulting from cyclic and bidirectional loading. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

5.
The effectiveness of a rehabilitation method based on joint enlargement using prestressed steel angles to enhance the seismic behavior of damaged external reinforced concrete beam‐column joints was experimentally investigated. Three half‐scale joints having either non‐seismic or seismic reinforcement details were tested both before and after rehabilitation by applying lateral cyclic loading of increasing amplitudes. Two defects were considered for the two non‐seismic units, being the absence of transverse steel hoops and insufficient bond capacity of beam bottom steel reinforcing bars in the joint panel zone. The damaged specimens were rehabilitated by injecting epoxy grout into existing cracks and installing stiffened steel angles at the re‐entrant corners of the beam‐column joint, both above and below the beam, that were mounted and held in place using prestressed high‐tensile strength bars. The test results indicated that the seismic performance of the rehabilitated specimens in terms of strength, stiffness, and ductility was fully recovered and comparable with the performance of the seismically detailed specimen. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
This paper presents the results of a multi‐level pseudo‐dynamic seismic test program that was performed to assess the performance of a full‐scale three‐bay, two‐storey steel–concrete composite moment‐resisting frame built with partially encased composite columns and partial‐strength beam‐to‐column joints. The system was designed to develop a ductile response in the joint components of beam‐to‐column joints including flexural yielding of beam end plates and shear yielding of the column web panel zone. The ground motion producing the damageability limit state interstorey drift caused minor damage while the ultimate limit state ground motion level entailed column web panel yielding, connection yielding and plastic hinging at the column base connections. The earthquake level chosen to approach the collapse limit state induced more damage and was accompanied by further column web panel yielding, connection yielding and inelastic phenomena at column base connections without local buckling. During the final quasi‐static cyclic test with stepwise increasing displacement–amplitudes up to an interstorey drift angle of 4.6%, the behaviour was ductile although cracking of beam‐to‐end‐plate welds was observed. Correlations with numerical simulations taking into account the inelastic cyclic response of beam‐to‐column and column base joints are also presented in the paper together. Inelastic static pushover and time history analysis procedures are used to estimate the structural behaviour and overstrength factors of the structural system under study. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
The seismic response of non‐ductile reinforced concrete (RC) buildings can be affected by the behaviour of beam‐column joints involved in the failure mechanism, especially in typical existing buildings. Conventional modelling approaches consider only beam and column flexibility, although joints can provide a significant contribution also to the overall frame deformability. In this study, the attention is focused on exterior joints without transverse reinforcement, and a possible approach to their modelling in nonlinear seismic analysis of RC frames is proposed. First, experimental tests performed by the authors are briefly presented, and their results are discussed. Second, these tests, together with other tests with similar features from literature, are employed to calibrate the joint panel deformability contribution in order to reproduce numerically the experimental joint shear stress–strain behaviour under cyclic loading. After a validation phase of this proposal, a numerical investigation of the influence of joints on the seismic behaviour of a case study RC frame – designed for gravity loads only – is performed. The preliminary failure mode classification of the joints within the analysed frame is carried out. Structural models that (i) explicitly include nonlinear behaviour of beam‐column joints exhibiting shear or anchorage failure or (ii) model joints as elements with infinite strength and stiffness are built and their seismic performance are assessed and compared. A probabilistic assessment based on nonlinear dynamic simulations is performed by means of a scaling approach to evaluate the seismic response at different damage states accounting for uncertainties in ground‐motion records. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
The feasibility and efficiency of a seismic retrofit solution for existing reinforced concrete frame systems, designed before the introduction of modern seismic‐oriented design codes in the mid 1970s, is conceptually presented and experimentally investigated. A diagonal metallic haunch system is introduced at the beam–column connections to protect the joint panel zone from extensive damage and brittle shear mechanisms, while inverting the hierarchy of strength within the beam–column subassemblies and forming a plastic hinge in the beam. A complete step‐by‐step design procedure is suggested for the proposed retrofit strategy to achieve the desired reversal of strength hierarchy. Analytical formulations of the internal force flow at the beam–column‐joint level are derived for the retrofitted joints. The study is particularly focused on exterior beam–column joints, since it is recognized that they are the most vulnerable, due to their lack of a reliable joint shear transfer mechanism. Results from an experimental program carried out to validate the concept and the design procedure are also presented. The program consisted of quasi‐static cyclic tests on four exterior, ? scaled, beam–column joint subassemblies, typical of pre‐1970 construction practice using plain round bars with end‐hooks, with limited joint transverse reinforcement and detailed without capacity design considerations. The first (control specimen) emulated the as‐built connection while the three others incorporated the proposed retrofitted configurations. The experimental results demonstrated the effectiveness of the proposed solution for upgrading non‐seismically designed RC frames and also confirmed the applicability of the proposed design procedure and of the analytical derivations. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
The seismic performance of post‐tensioned steel connections for moment‐resisting frames was examined experimentally and analytically. Cyclic tests were conducted on three full‐scale subassemblies, which had two steel beams post‐tensioned to a concrete‐filled tube (CFT) column with high‐strength strands to provide recentring response. Reduced flange plates (RFPs) welded to the column and bolted to the beam flange were used to increase the dissipation of energy. Test results indicated that (1) the proposed buckling‐restrained RFP could dissipate energy in axial tension and compression, (2) the subassemblies could reach an interstorey drift of 4% without strength degradation, and (3) buckling of the beam occurred towards an interstorey drift of 5%, causing a loss of the strand force, the recentring response, and the moment capacity. A general‐purpose non‐linear finite element analysis program (ABAQUS) was used to perform a correlation study. The behaviour of the steel beam under both post‐tensioning and flexural loadings was compared to the test results and predictions. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

10.
The potential of post‐tensioned self‐centering moment‐resisting frames (SC‐MRFs) and viscous dampers to reduce the economic seismic losses in steel buildings is evaluated. The evaluation is based on a prototype steel building designed using four different seismic‐resistant frames: (i) conventional moment resisting frames (MRFs); (ii) MRFs with viscous dampers; (iii) SC‐MRFs; or (iv) SC‐MRFs with viscous dampers. All frames are designed according to Eurocode 8 and have the same column/beam cross sections and similar periods of vibration. Viscous dampers are designed to reduce the peak story drift under the design basis earthquake (DBE) from 1.8% to 1.2%. Losses are estimated by developing vulnerability functions according to the FEMA P‐58 methodology, which considers uncertainties in earthquake ground motion, structural response, and repair costs. Both the probability of collapse and the probability of demolition because of excessive residual story drifts are taken into account. Incremental dynamic analyses are conducted using models capable to simulate all limit states up to collapse. A parametric study on the effect of the residual story drift threshold beyond which is less expensive to rebuild a structure than to repair is also conducted. It is shown that viscous dampers are more effective than post‐tensioning for seismic intensities equal or lower than the maximum considered earthquake (MCE). Post‐tensioning is effective in reducing repair costs only for seismic intensities higher than the DBE. The paper also highlights the effectiveness of combining post‐tensioning and supplemental viscous damping by showing that the SC‐MRF with viscous dampers achieves significant repair cost reductions compared to the conventional MRF. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
The self‐centering prestressed concrete (SCPC) moment resisting frame (MRF) with web friction devices (WFDs) is a new type of structure that integrates advantages of post‐tensioned precast concrete MRFs and self‐centering steel MRFs. In this paper, the configuration of the connection and design guidelines are presented. To further reduce damage to the connection under cyclic loading and facilitate implementation in practice, several significant improvements are proposed and experimentally validated in this study, including the following: (i) the welded connection is replaced by the bolted connection; (ii) aluminum plates are used for friction instead of brass plates to reduce the material costs without decreasing the energy dissipation capacity; and (iii) post‐tensioned tendons at the corners of the beam are replaced by a bundle of tendons at the beam centroid in order to facilitate the field assembly. The resulting improvements of seismic performances are experimentally demonstrated by 10 cyclic tests of two full‐scale SCPC beam–column connections. Numerical simulation of the proposed connection is conducted using the Open System for Earthquake Engineering Simulation (OpenSees) to replicate the experimental results. Seismic behaviors are taken into account, such as the gap opening/closing at the beam–column interface, the self‐centering capacity, and the friction energy dissipation. Good agreement is observed between the numerical simulation and the test results. The proposed SCPC connection with bolted WFDs is demonstrated to have good performance when subjected to cyclic loading. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
This paper investigates the effect of the composite action on the seismic performance of steel special moment frames (SMFs) through collapse. A rational approach is first proposed to model the hysteretic behavior of fully restrained composite beam‐to‐column connections, with reduced beam sections. Using the proposed modeling recommendations, a system‐level analytical study is performed on archetype steel buildings that utilize perimeter steel SMFs, with different heights, designed in the West‐Coast of the USA. It is shown that in average, the composite action may enhance the seismic performance of steel SMFs. However, bottom story collapse mechanisms may be triggered leading to rapid deterioration of the global strength of steel SMFs. Because of composite action, excessive panel zone shear distortion is also observed in interior joints of steel SMFs designed with strong‐column/weak‐beam ratios larger than 1.0. It is demonstrated that when steel SMFs are designed with strong‐column/weak‐beam ratios larger than 1.5, (i) bottom story collapse mechanisms are typically avoided; (ii) a tolerable probability of collapse is achieved in a return period of 50 years; and (iii) controlled panel zone yielding is achieved while reducing the required number of welded doubler plates in interior beam‐to‐column joints. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
The seismic response of single‐degree‐of‐freedom (SDOF) systems incorporating flag‐shaped hysteretic structural behaviour, with self‐centring capability, is investigated numerically. For a SDOF system with a given initial period and strength level, the flag‐shaped hysteretic behaviour is fully defined by a post‐yielding stiffness parameter and an energy‐dissipation parameter. A comprehensive parametric study was conducted to determine the influence of these parameters on SDOF structural response, in terms of displacement ductility, absolute acceleration and absorbed energy. This parametric study was conducted using an ensemble of 20 historical earthquake records corresponding to ordinary ground motions having a probability of exceedence of 10% in 50 years, in California. The responses of the flag‐shaped hysteretic SDOF systems are compared against the responses of similar bilinear elasto‐plastic hysteretic SDOF systems. In this study the elasto‐plastic hysteretic SDOF systems are assigned parameters representative of steel moment resisting frames (MRFs) with post‐Northridge welded beam‐to‐column connections. In turn, the flag‐shaped hysteretic SDOF systems are representative of steel MRFs with newly proposed post‐tensioned energy‐dissipating connections. Building structures with initial periods ranging from 0.1 to 2.0s and having various strength levels are considered. It is shown that a flag‐shaped hysteretic SDOF system of equal or lesser strength can always be found to match or better the response of an elasto‐plastic hysteretic SDOF system in terms of displacement ductility and without incurring any residual drift from the seismic event. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents the development, experimental testing, and numerical modelling of a new hybrid timber‐steel moment‐resisting connection that is designed to improve the seismic performance of mid‐rise heavy timber moment‐resisting frames (MRF). The connection detail incorporates specially designed replaceable steel links fastened to timber beams and columns using self‐tapping screws. Performance of the connection is verified through experimental testing of four 2/3 scale beam‐column connections. All 4 connection specimens met the acceptance criteria specified in the AISC 341‐10 provisions for steel moment frames and exhibit high strength, ductility, and energy dissipation capacity up to storey drifts exceeding 4%. All of the timber members and self‐tapping screw connections achieved their design objective, remaining entirely elastic throughout all tests and avoiding brittle modes of failure. To assess the global seismic performance of the newly developed connection in a mid‐rise building, a hybrid timber‐steel building using the proposed moment‐resisting connection is designed and modelled in OpenSees. To compare the seismic performance of the hybrid MRF with a conventional steel MRF, a prototype steel‐only building is also designed and modelled in OpenSees. The building models are subject to a suite of ground motions at design basis earthquake and maximum credible earthquake hazard levels using non‐linear time history analysis. Analytical results show that drifts and accelerations of the hybrid building are similar to a conventional steel building while the foundation forces are significantly reduced for the hybrid structure because of its lower seismic weight. The results of the experimental program and numerical analysis demonstrate the seismic performance of the proposed connection and the ability of the hybrid building to achieve comparable seismic performance to a conventional steel MRF.  相似文献   

15.
The paper investigates the dynamic behaviour of hybrid systems made of partially restrained (PR) steel–concrete composite frames coupled with viscoelastic dissipative bracings. A numerical model that accounts for both the resisting mechanisms of the joint and the viscoelastic contribution of the dissipative bracing is introduced and briefly discussed. The model is first validated against experimental outcomes obtained on a one‐storey two‐bay composite frame with partial strength semi‐rigid joints subjected to free vibrations. A number of time‐history analyses under different earthquake ground motions and peak ground accelerations are then carried out on the same type of frame. The purpose is to investigate the influence of the type of beam‐to‐column connection and property of the viscoelastic bracing on the performance of the hybrid system. The inherent stiffness of the bare PR frame and the plastic hysteresis of the beam‐to‐column joints, which always lead to only limited damage in the joint, are found to provide a significant contribution to the overall structural performance even under destructive earthquakes. This remark leads to the conclusion that the viscoelastic bracing can be effectively used within the hybrid system. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
Numerous non‐ductile reinforced concrete (RC) buildings with little or no shear reinforcement in beam‐column joints can be found in regions of moderate seismicity. To strengthen such substandard beam‐column joints, this study proposes a method in which RC wing walls are installed beside existing columns, which overcomes the lack of realistic strengthening methods for congested connections in RC buildings. The proposed strengthening mechanism improves the joint moment capacity by utilizing tension and compression acting on the beam–wing wall boundaries; thus, brittle joint hinging failure is prevented. Three 3/4‐scale RC exterior beam‐column joint specimens without shear reinforcement, two of which were strengthened by installing wing walls with different strengthening elements, were fabricated and tested. The test results verified the effectiveness of the proposed strengthening method and the applicability of this method to seismically substandard beam‐column joints. © 2017 The Authors. Earthquake Engineering & Structural Dynamics Published by John Wiley & Sons Ltd.  相似文献   

17.
18.
This paper investigates the seismic behaviour of moment‐resisting timber frames with beam‐column joints fastened with expanded tubes and reinforced with densified veneer wood. Laboratory experiments are carried out on single joints to investigate the cyclic behaviour and, more specifically, the impairment of strength, the ductility ratio and the equivalent viscous damping ratio. A phenomenological numerical model is proposed, where the beams and columns are schematized using linear‐elastic beam elements, and the joints with non‐linear hysteretic spring calibrated on the results of the experimental tests. The model is used to analyse some representative moment‐transmitting structures characterised by different number of bays and storeys. After an estimation of the lateral load‐carrying capacity using a pushover analysis, the numerical model is used to estimate the behaviour factor. An incremental dynamic analysis is performed using a set of accelerograms spectrum consistent with a chosen design spectrum. The analyses lead to an estimation of the behaviour factor of 3 and 6 for a portal frame and a five‐storey, three‐bay frame, respectively, which confirms the highly dissipative behaviour of this kind of moment connection. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

19.
The work presented is aimed at the investigation of the influence of beam‐to‐column connections on the seismic response of MR‐Frames, with and without ‘set‐backs’, designed according to the Theory of Plastic Mechanism Control. The investigated connection typologies are four partial strength connections whose structural details have been designed to obtain the same flexural resistance. The first three joints are designed by means of hierarchy criteria based on the component approach and are characterized by different location of the weakest joint component, leading to different values of joint rotational stiffness and plastic rotation supply and affecting the shape of the hysteresis loops governing the dissipative capacity. The last typology is a beam‐to‐column connection equipped with friction pads devoted to the dissipation of the earthquake input energy, thus preventing the connection damage. An appropriate modelling is needed to accurately represent both strength and deformation characteristics, especially with reference to partial‐strength connections where the dissipation of the earthquake input energy occurs. To this aim, beam‐to‐column joints are modelled by means of rotational inelastic springs located at the ends of the beams whose moment‐rotation curve is characterized by a cyclic behaviour which accounts for stiffness and strength degradation and pinching phenomena. The parameters characterizing the cyclic hysteretic behaviour have been calibrated on the base of experimental results aiming to the best fitting. Successively, the prediction of the structural response of MR‐Frames, both regular frames and frames with set‐backs, equipped with such connections has been carried out by means of both push‐over and Incremental Dynamic Analyses. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
The seismic damages commonly observed on beam–column joints of old reinforced concrete structures, built with plain bars and without proper detailing, justifies the need to further study the behaviour of this type of structures. The response of these structures when loaded cyclically, as occurs during the earthquakes, is partially controlled by the bond properties between the reinforcing bars and the surrounding concrete. This paper presents the results of an experimental campaign of unidirectional cyclic tests carried out on six full‐scale beam–column joints built with plain bars. These joint specimens are representative of existing reinforced concrete structures, that is, built without adequate reinforcement detailing for seismic demands. For comparison, an additional specimen is built with deformed bars and tested. The seven specimens are designed and detailed to allow the investigation of the influence of bond properties, lapping of the longitudinal bars in columns and beams, bent‐up bars in the beams, slab contribution and concrete strength. The lateral force–drift relationships, global dissipated energy evolution, contribution of the joint, beams and columns to the global dissipated energy, ductility, equivalent damping, final damage observed, homogenized reinforced concrete damage index, displacement components, curvature evolutions and Eurocode requirements are presented and discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号