1.
This paper presents the results of 56 large‐amplitude shake table tests of a 30% scale eight‐storey controlled rocking steel frame. No significant damage or residual deformations were observed after any of the tests. The frame had four possible configurations on the basis of combinations of two higher mode mitigation mechanisms. The first mitigation mechanism was formed by allowing the upper section of the frame to rock, so as to better control the mid‐height overturning moment. The second mitigation mechanism was formed by replacing the conventional first‐storey brace with a self‐centering energy dissipative (SCED) brace, so as to better control the base shear. The mechanisms had little effect during records where higher mode effects were not apparent, but they substantially reduced the shear and overturning moment envelopes, as well as the peak floor accelerations, during more demanding records. The reduction in storey shears led to similarly reduced brace force demands. Although the peak force demands in the columns were not reduced by as much as the frame overturning moments, using an upper rocking joint allowed the column demands to be estimated without the need to assume a lateral force distribution. The tests demonstrated that multiple force‐limiting mechanisms can be used to provide better control of peak seismic forces without excessive increases in drift demands, thus enabling more reliable capacity design. These results are expected to be widely applicable to structures where the peak seismic forces are significantly influenced by higher mode effects. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
In the conventional seismic design of high‐rise reinforced concrete core‐wall buildings, the design demands such as design shear and bending moment in the core wall are typically determined by the response spectrum analysis procedure, and a plastic hinge is allowed to form at the wall base to limit the seismic demands. In this study, it is demonstrated by using a 40‐story core‐wall building that this conventional approach could lead to an unsafe design where the true demands—the maximum inelastic seismic demands induced by the maximum considered earthquake—could be several times greater than the design demands and be unproportionately dominated by higher vibration modes. To identify the cause of this problem, the true demands are decomposed into individual modal contributions by using the uncoupled modal response history analysis procedure. The results show that the true demands contributed by the first mode are reasonably close to the first‐mode design demands, while those contributed by other higher modes are much higher than the corresponding modal design demands. The flexural yielding in the plastic hinge at the wall base can effectively suppress the seismic demands of the first mode. For other higher modes, however, a similar yielding mechanism is either not fully mobilized or not mobilized at all, resulting in unexpectedly large contributions from higher modes. This finding suggests several possible approaches to improve the seismic design and to suppress the seismic demands of high‐rise core‐wall buildings. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
This paper investigates the seismic response of tall cantilever wall buildings subjected to pulse type ground motion, with special focus on the relation between the characteristics of ground motion and the higher‐modes of response. Buildings 10, 20, and 40 stories high were designed such that inelastic deformation was concentrated at a single flexural plastic hinge at their base. Using nonlinear response history analysis, the buildings were subjected to near‐fault seismic ground motions and simple closed‐form pulses, which represented distinct pulses within the ground motions. Euler–Bernoulli beam models with lumped mass and lumped plasticity were used to model the buildings. The response of the buildings to the closed‐form pulses fairly matched that of the near‐fault records. Subsequently, a parametric study was conducted for the buildings subjected to three types of closed‐form pulses with a broad range of periods and amplitudes. The results of the parametric study demonstrate the importance of the ratio of the fundamental period of the structure to the period of the pulse to the excitation of higher modes. The study shows that if the modal response spectrum analysis approach is used — considering the first four modes with a uniform yield reduction factor for all modes, and with the square root of sum of squares modal combination rule — it significantly underestimates bending moment and shear force responses. A response spectrum analysis method that uses different yield reduction factors for the first and the higher modes is presented. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
The modal base forces in structures having a straight-line mode of vibration are investigated. Making use of the orthogonality relationship between the different modes, a relation between the modal base shears and base moments is found in all but the straight-line mode. This relation states that the contribution of the inertia forces to the modal overturning moments referred to the centre of rotation of the straight-line mode is identically null. The contributions of the vertical forces and lateral constraints must, however, be accounted for. For the special case of the straight-line mode being proportional to the height of each storey, the centre of rotation coincides with the base of the structure. For the case of the straight-line mode being a uniform displacement, the centre of rotation is at infinity and the contribution of the inertia forces to the modal base shears identically disappears in all but the straight-line mode.  相似文献   

5.
Four real buildings with three to six stories, strong irregularities in plan and little engineered earthquake resistance are subjected to inelastic response‐history analyses under 56 bidirectional EC8‐spectra‐compatible motions. The average chord rotation demand at each member end over the 56 response‐history analyses is compared to the chord rotation from elastic static analysis with inverted triangular lateral forces or modal response spectrum analysis. The storey‐average inelastic‐to‐elastic‐chord‐rotation‐ratio was found fairly constant in all stories, except when static elastic analysis is applied to buildings with large higher mode effects. Except for such buildings, static elastic analysis gives more uniform ratios of inelastic chord rotations to elastic ones within and among stories than modal response spectrum analysis, but generally lower than 1.0. With increasing EPA the building‐average inelastic‐to‐elastic‐chord‐rotation‐ratio decreases but scatter in the results increases. Static elastic analysis tends to overestimate the inelastic torsional effects at the flexible or central part of the torsionally flexible buildings and underestimate them at their stiff side. Modal response spectrum analysis tends to overestimate the inelastic torsional effects at the stiff or central part of the torsionally stiff buildings and underestimate them at the flexible side. Overall, for multistorey RC buildings that typically have fundamental periods in the velocity‐sensitive part of the spectrum, elastic modal response spectrum analysis with 5% damping gives on average unbiased and fairly accurate estimates of member inelastic chord rotations. If higher modes are not significant, elastic static analysis in general overestimates inelastic chord rotations of such buildings, even when torsional effects are present. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

6.
Two approximate methods for decomposing complicated inelastic dynamic responses of wall buildings into simple modal responses are presented. Both methods are based on the equivalent linear concept, where a non‐linear structure is represented by a set of equivalent linear models. One linear model is used for representing only one vibration mode of the non‐linear structure, and its equivalent linear parameters are identified from the inelastic response time histories by using a numerical optimizer. Several theoretical relations essential for the modal decomposition are derived under the framework of complex modal analysis. Various numerical examinations have been carried out to check the validity of the proposed modal decomposition methods, and the results are quite satisfactory in all cases. Fluctuating bending moment and shear at any location along the wall height contributed by each individual vibration mode can be obtained. Modal contributions to shear and flexural strength demands, as well as the corresponding modal properties, under various seismic loading conditions can also be identified and examined in detail. Furthermore, the effects of higher vibration modes on seismic demands of wall buildings are investigated by using the modal decomposition methods. Several new insights into the complicated inelastic dynamics of multi‐story wall buildings are presented. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

7.
Damage assessments after past earthquakes have frequently revealed that plan configuration irregular buildings have more severe damage due to excessive torsional responses and stress concentration than regular buildings. The plan configuration irregularities introduce major challenges in the seismic design of buildings. One such form of irregularity is the presence of re-entrant corners in the L-shaped buildings that causes stress concentration due to sudden changes in stiffness and torsional response amplification; hence causes early collapse. A constructive research into re-entrant corner and torsional irregularity problems is essentially needed greater than ever. Therefore, the focus of this study is to investigate structural seismic response demands for the class of L-shaped buildings through evaluating the plan configuration irregularity of re-entrant corners and lateral–torsion coupling effects on measured seismic response demands. The measured responses include story drift, inter-story drift, story shear force, overturning moment, torsion moment at the base and over building height, and torsional irregularity ratio. Three dimensional finite element model for nine stories symmetric buildings as reference model is developed. In addition, six L-shaped building models are formulated with gradual reduction in the plan of the reference building model. The results prove that building models with high irregularity are more vulnerable due to the stress concentration and lateral torsional coupling behavior than that with regular buildings. In addition, the related lateral shear forces in vertical resisting elements located on the periphery of the L-shaped buildings could be significantly increased in comparison with the corresponding values for a symmetric building.  相似文献   

8.
A series of shaking table tests on a 1:12‐scale model using scaled TaftN21E earthquake records were conducted to investigate the seismic performance of a 17‐storey high‐rise reinforced concrete structure with a high degree of torsional eccentricity and soft‐storey irregularities in the bottom two storeys. Based on the analysis of test results, the following conclusions were drawn: (1) the model responded mainly in the coupled mode of translation and torsion or in the torsional mode. Under severe table shaking, the flexible side underwent large inelastic deformation, and the predominant mode of the model changed from the coupled mode to the torsional mode, resulting in greatly increased torsional stiffness, thereby limiting damage in the flexible frame; (2) the shear force and deformation of the flexible side were governed by the torsional behaviour, whereas those of the stiff side were affected mainly by the overturning deformation. The lateral stiffness of the shear wall in the torsional mode was about four times that in the coupled mode because the warping deformation due to torsion counteracted the flexural deformation due to overturning moment in the torsional mode; and (3) the reversed cyclic overturning moments predicted by linear elastic dynamic analysis in the direction transverse to the table excitations contradicted unilateral overturning moments of the serviceability‐level test results, which showed a bias towards tension or compression in the columns. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
This paper reports a study for the seismic performance of one large‐scaled (1/15) model of 30‐story steel‐reinforced concrete frame‐concrete core wall mixed structure. The study was implemented by both shaking table tests, in which the similarity ratio for lateral and gravitational accelerations was kept to 1:1, and numerical nonlinear dynamic analysis. The test observations presented herein include story displacement, interstory drift, natural vibration periods, and final failure mode. The numerical analysis was performed to simulate the shaking table test procedure, and the numerically obtained responses were verified by the test results. On the basis of the numerical results, the progressions of structural stiffness, base shear, and overturning moment were investigated, and the distributions of base shear and overturning moment between frame and core wall were also discussed. The test demonstrates the seismic performance of the steel‐reinforced concrete frame‐core wall mixed structure and reveals the potential overturning failure mode for high rise structures. The nonlinear analysis results indicate that the peripheral frames could take more shear forces after core wall damaged under severe earthquakes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
The extended N2 method taking into account higher mode effects in elevation   总被引:1,自引:0,他引:1  
The N2 method has been extended in order to take into account higher mode effects in elevation. The extension is based on the assumption that the structure remains in the elastic range when vibrating in higher modes. The seismic demand in terms of displacements and storey drifts can be obtained by enveloping the results of basic pushover analysis and the results of standard elastic modal analysis. The approach is consistent with the extended N2 method used for plan‐asymmetric buildings. The proposed procedure was applied to three variants of three steel frame buildings used in the SAC project. The structural response was investigated for two sets of ground motions. Different ground motion intensities were used in order to investigate the influence of the magnitude of plastic deformations. The N2 results were compared with the results of nonlinear response‐history analysis, two other pushover‐based methods (modal pushover analysis (MPA) and modified MPA (MMPA)), and pushover analysis without consideration of higher modes. It was found that a considerable influence of higher modes on storey drifts is present at the upper part of medium‐and high‐rise structures. This effect is the largest in the case of elastic behaviour and decreases with ground motion intensity. The higher mode effects also depend on the spectral shape. The approximate methods (extended N2, MPA and MMPA) are able to provide fair estimates of response in the case of the test examples. Accuracy decreases with the height of the building, and with the intensity of ground motion. The N2 results are generally conservative. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
This paper deals with seismic analysis of plan‐asymmetric r/c frame multi‐storey buildings. Non‐linear numerical analyses are carried out by using a lumped plasticity model for beams and a multi‐spring model for columns, the latter one introduced to account for axial force–biaxial bending moment interaction. A comparison between numerical analyses and experimental test results is reported in order to calibrate the numerical model, showing that the adopted model is very suitable. In order to study the effects of the earthquake orthogonal component, the seismic response of the modelled structure under uni‐directional excitation is compared to the one under bi‐directional excitation. Such comparison shows that the maximum base shear and the top displacement are not very sensitive to the presence of the orthogonal component, which, conversely, leads to large increase in the column plastic excursions. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

12.
林树潮     《世界地震工程》2021,(1):129-136
为了研究高阶晃动振型对LNG储罐地震响应的影响,考虑高阶晃动振型,建立LNG储罐的简化力学模型,推导LNG储罐的运动控制方程,给出了LNG储罐的基底剪力、倾覆弯矩和储罐内液体晃动波高的表达式。以某16×104 m3 LNG储罐为例,采用大型通用有限元分析软件ADINA System对其进行有限元模型分析,验证其修正模型的有效性,结果表明:高阶晃动振型对基底剪力和倾覆弯矩几乎无影响,但对晃动波高影响显著,尤其是长周期地震动作用下,并且考虑高阶晃动振型的晃动波高存在延时效应。提出的简化力学模型修正公式与有限元分析结果吻合较好,可以准确地预测LNG储罐地震响应。  相似文献   

13.
This paper aims to extend the consecutive modal pushover (CMP) procedure for estimating the seismic demands of two-way unsymmetric-plan tall buildings subjected to bi-directional seismic ground motions taking the effects of higher modes and torsion into account. Multi-stage and single-stage pushover analyses are carried out in both X and Y directions. Inelastic seismic responses obtained by multi-stage and single-stage pushover analyses for X and Y directions are combined using the SRSS combination scheme. The final seismic responses are determined by enveloping the combined results of multi-stage and single-stage pushover analyses. To evaluate the accuracy of the proposed procedure, it is applied to two-way unsymmetric-plan tall buildings which include torsionally stiff and torsionally flexible systems. The results derived from the CMP procedure are compared with those from nonlinear response history analysis (NL-RHA), as a benchmark solution. Moreover, the advantages of the proposed procedure are demonstrated by comparing the results derived from the CMP to those from pushover analysis with uniform and fundamental effective mode distributions. The proposed procedure is able to accurately predict amplification or de-amplification of the seismic displacements at the flexible and stiff edges of the two-way unsymmetric-plan tall buildings by considering the effects of higher modes and torsion. The extended CMP procedure can accurately estimate the peak inelastic responses, such as displacements and storey drifts. The CMP procedure features a higher potential in estimating plastic hinge rotations at both flexible and stiff sides of unsymmetric-plan tall buildings under bi-directional seismic excitation when compared to the uniform and fundamental effective mode force distributions.  相似文献   

14.
This paper presents a detailed study on feasibility of un‐bonded fiber reinforced elastomeric isolator (U‐FREI) as an alternative to steel reinforced elastomeric isolator (SREI) for seismic isolation of un‐reinforced masonry buildings. Un‐reinforced masonry buildings are inherently vulnerable under seismic excitation, and U‐FREIs are used for seismic isolation of such buildings in the present study. Shake table testing of a base isolated two storey un‐reinforced masonry building model subjected to four prescribed input excitations is carried out to ascertain its effectiveness in controlling seismic response. To compare the performance of U‐FREI, same building is placed directly on the shake table without isolator, and fixed base (FB) condition is simulated by restraining the base of the building with the shake table. Dynamic response characteristic of base isolated (BI) masonry building subjected to different intensities of input earthquakes is compared with the response of the same building without base isolation system. Acceleration response amplification and peak response values of test model with and without base isolation system are compared for different intensities of table acceleration. Distribution of shear forces and moment along the height of the structure and response time histories indicates significant reduction of dynamic responses of the structure with U‐FREI system. This study clearly demonstrates the improved seismic performance of un‐reinforced masonry building model supported on U‐FREIs under the action of considered ground motions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
This article reports a method to determine the storey‐wise column size for displacement‐based design of reinforced concrete frame buildings with a wide range of storey drift and building plan. The method uses a computer program based algorithm. The basic relation used in the algorithm is formulated by considering the various possible deformation components involved in the overall frame deformation. As a necessity to represent the deformation component due to plastic rotation of beam members, a relation between the beam plastic rotation and the target‐drift is adopted. To control the dynamic amplification of interstorey drift, a target‐drift dependant design‐drift reduction factor is used. The dynamic amplification of column moment is accounted with the help of an approximate conversion of fundamental period of the building from the effective period of the equivalent SDOF system. To avoid the formation of plastic hinge in column members, a design‐drift dependant column–beam moment capacity ratio is used. The method successfully determines the storey‐wise column size for buildings of four plans of different varieties, heights up to 12 storeys and target‐drift up to 3%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
This paper aims to shed some further light on the seismic behaviour and design of reinforced concrete (R/C) walls which form part of dual (frame + wall) structures. The significance of post‐elastic dynamic effects is recognized by most seismic codes in the definition of the design action effects on walls, i.e. bending moments and shear forces. However, the resulting envelopes are not always fully satisfactory, particularly in the case of medium‐to‐high‐rise buildings. The relevant provisions of modern seismic codes are first summarized and their limitations discussed. Then an extensive parametric study is presented which involves typical multi‐storey dual systems that include walls with unequal lengths, designed according to the provisions of Eurocode 8 for two different ductility classes (M and H) and two effective peak ground acceleration levels (0.16 and 0.24g). The walls of these structures are also designed according to other methods, such as those used in New Zealand and Greece. The resulting different designs are then assessed by subjecting the structures to a suite of records from strong ground motions, carrying out inelastic time history analysis, and comparing the results with the design action effects. It is found that for (at least) the design earthquake intensity, the first two modes of vibration suffice for describing the seismic response of the walls. The bending moment envelope, as well as the base shear of each wall, is found to be strongly dependent on the second mode effect. As far as the code‐prescribed design action effects are concerned, only the NZ Code was found to be consistently conservative, whereas this was not always the case with EC8. A new method is then proposed which focuses on quantifying in a simple way the second mode effects in the inelastic response of the walls. This procedure seems to work better than the others evaluated herein. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
A novel model for assessing building behavior has been developed by coupling a Bernoulli beam with a quartic stiffness variation and a shear beam with a parabolic stiffness variation, trends that are expected in buildings designed for earthquake actions. Then the partial differential equation of motion governing the behavior of the model has been solved, obtaining analytic expressions (Closed form solutions) for mode shapes in terms of Legendre functions. These closed form solutions were validated with finite element model analyses and effects of non-uniformity of stiffness were assessed in a generalized manner. It was found that period lengthening is mild for the first mode, but for higher modes can be far more noticeable if shear stiffness at beam top is <20 % of its base value. Mode shapes also change notoriously for reductions beyond the same limit, potentially inducing large floor acceleration demands at unexpected locations. Also it was found that drift demands can be noticeably enhanced even if shear stiffness at top is 75 % of the base value, in what would be considered uniform buildings. This model has several applications for assessing the response or large stocks of buildings, calibrate complex models, assess damage on building contents, establishing in short time damage scenarios for large cities, and could be helpful for education, as emphasis is brought back on fundamental concepts.  相似文献   

19.
The quality of construction is one of the main factors that affect the seismic vulnerability of structures. The damage observations of modern buildings after almost all recent earthquakes report cases of poor quality of materials, inadequate detailing of reinforcement and absence of capacity design principles. Looking at the modern codes for seismic design, which rely on high behaviour factor supplies, the assessment of the effects of poor quality of execution in otherwise well‐conceived and well‐designed structures becomes an important problem. This paper presents an experiment‐based estimation of the seismic response of a cast‐in‐situ one‐storey industrial reinforced concrete frame designed according to Eurocodes. The influence of the quality of construction is estimated by consideration of two models of the experimental prototype: a structure erected under strict measures for control of the quality of execution, and a structure erected with normal measures for control of the quality of execution which resulted in significant deficiencies in the practical arrangement of the reinforcement. On the basis of the experimental data the ductility and behaviour factor supplies of the two structures are estimated. Quantitative expressions for the influence of the quality of construction on the first yield displacement, ultimate storey displacement, maximum base‐shear force and behaviour factor supply are provided. Recommendations for the refinement of modern seismic design codes, particularly Eurocode 8, to take into account the quality of construction are given. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

20.
A procedure for incorporating record‐to‐record variability into the simplified seismic assessment of RC wall buildings is presented. The procedure relies on the use of the conditional spectrum to randomly sample spectral ordinates at relevant periods of vibration. For inelastic response, displacement reduction factors are then used to relate inelastic displacement demand to the spectral displacement at the effective period for single‐degree‐of‐freedom systems. Simple equations are used to convert back and forth between multi‐degree‐of‐freedom RC wall buildings and equivalent single‐degree‐of‐systems so that relevant engineering demand parameters can be obtained. Consideration is also given to higher‐mode effects by adapting existing modal combination rules. The proposed method is applied to several case study buildings, showing promising results in the examination of inter‐storey drift ratio and shear forces. The proposed method captures the variation in the distribution of structural response parameters that occurs with variations in structural configuration, intensity, engineering demand parameter of interest and site characteristics. Discussion is provided on possible ways to improve the accuracy of the procedure and suggestions for additional future work. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   