首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
AQUIPRO, a PC-based method, was used to assess aquifer vulnerability using digital water well logs. The AQUIPRO model is a parameter/factor weighting system for rating the pollution potential of an aquifer. This method uses the well depth, as well as the clay and partial clay thickness in a well, to generate pollution potential scores. In this model, aquifer protection increases as the AQUIPRO vulnerability scores increase and ground water pollution potential decreases. Computerized water well records of 2435 domestic wells with partial chemistry data were used to determine the ground water pollution potential of Kalamazoo County, Michigan. Theoretically, low AQUIPRO pollution potential scores should have more frequent occurrences of ground water contamination events than areas with high AQUIPRO scores with similar land-use, well construction, and well densities. The relative AQUIPRO scores were compared with the frequency of occurrences of nitrate-N in ground water wells. The average nitrate-N concentrations within each relative AQUIPRO vulnerability scores category were also compared. The results indicate that domestic wells containing 5 mg/L or more nitrate-N showed a positive correlation between the frequency of occurrences of nitrate-N and relative decrease of AQUIPRO (r2 = 0.99) vulnerability scores. In other words, as the ground water pollution potential increases, the occurrence frequency of nitrate-N also increases. Furthermore, the results show that as the relative AQUIPRO (r2 = 0.96) vulnerability scores decrease, the mean nitrate-N concentrations also increase.  相似文献   

2.
The capture efficiency map: the capture zone under time-varying flow   总被引:3,自引:0,他引:3  
Festger AD  Walter GR 《Ground water》2002,40(6):619-628
The capture zone or contributing area of a ground water extraction well can be defined as that portion of the aquifer from which the well draws its water. Accurate delineation of capture zones is important in many ground water remediation applications and in the definition of wellhead protection areas. Their mathematical delineation is often simplified by using quasi-steady-state models based on time-weighted average pumping rates and background hydraulic gradients. We present a new semianalytic approach for the definition of capture zones under transient-flow conditions. We then use this approach to evaluate the effects of time variations in the direction of the background hydraulic gradient on capture. Results are presented in the form of capture efficiency maps (CEMs). Although the area contributing to a given well is found to generally expand relative to the steady-state average capture zone when the gradient direction varies, the zone of 100% capture may expand or contract depending on site-specific conditions. We illustrate our CEM approach by applying it to the design of a plume containment system.  相似文献   

3.
Integrated geophysical and chemical study of saline water intrusion   总被引:3,自引:0,他引:3  
Choudhury K  Saha DK 《Ground water》2004,42(5):671-677
Surface geophysical surveys provide an effective way to image the subsurface and the ground water zone without a large number of observation wells. DC resistivity sounding generally identifies the subsurface formations-the aquifer zone as well as the formations saturated with saline/brackish water. However, the method has serious ambiguities in distinguishing the geological formations of similar resistivities such as saline sand and saline clay, or water quality such as fresh or saline, in a low resistivity formation. In order to minimize the ambiguity and ascertain the efficacy of data integration techniques in ground water and saline contamination studies, a combined geophysical survey and periodic chemical analysis of ground water were carried out employing DC resistivity profiling, resistivity sounding, and shallow seismic refraction methods. By constraining resistivity interpretation with inputs from seismic refraction and chemical analysis, the data integration study proved to be a powerful method for identification of the subsurface formations, ground water zones, the subsurface saline/brackish water zones, and the probable mode and cause of saline water intrusion in an inland aquifer. A case study presented here illustrates these principles. Resistivity sounding alone had earlier failed to identify the different formations in the saline environment. Data integration and resistivity interpretation constrained by water quality analysis led to a new concept of minimum resistivity for ground water-bearing zones, which is the optimum value of resistivity of a subsurface formation in an area below which ground water contained in it is saline/brackish and unsuitable for drinking.  相似文献   

4.
Accurate representation of artificial recharge is requisite to calibration of a ground water model of an unconfined aquifer for a semiarid or arid site with a vadose zone that imparts significant attenuation of liquid transmission and substantial anthropogenic liquid discharges. Under such circumstances, artificial recharge occurs in response to liquid disposal to the vadose zone in areas that are small relative to the ground water model domain. Natural recharge, in contrast, is spatially variable and occurs over the entire upper boundary of a typical unconfined ground water model. An improved technique for partitioning artificial recharge from simulated total recharge for inclusion in a ground water model is presented. The improved technique is applied using data from the semiarid Hanford Site. From 1944 until the late 1980s, when Hanford's mission was the production of nuclear materials, the quantities of liquid discharged from production facilities to the ground vastly exceeded natural recharge. Nearly all hydraulic head data available for use in calibrating a ground water model at this site were collected during this period or later, when the aquifer was under the diminishing influence of the massive water disposals. The vadose zone is typically 80 to 90 m thick at the Central Plateau where most production facilities were located at this semiarid site, and its attenuation of liquid transmission to the aquifer can be significant. The new technique is shown to improve the representation of artificial recharge and thereby contribute to improvement in the calibration of a site-wide ground water model.  相似文献   

5.
The vadose zone is the portion of the geologic profile above a perennial aquifer. Inclusion of mandatory vadose zone monitoring techniques as an approach to aquifer protect ion was first proposed under the Resource Conservation and Recovery Act in the United States in 1978 and has since received increasing acceptance at federal and stale levels. The goals of a vadose zone characterization and monitoring effort are to establish background conditions, identify contaminant transport pathways, identify the extent and degree of existing contamination, establish the basis for monitoring network design, measure the parameters needed in a risk assessment, and provide detection of contaminant migration toward ground water resources. The benefits of vadose zone monitoring include early warning of contaminant migration, potential reduction of ground water monitoring efforts, reduction of contaminant spreading and volume, and reduced time and cost of remediation once a contaminant release occurs. Vadose zone characterization and monitoring techniques should be considered as critical hydrologic tools in the prevention of ground water resource degradation.  相似文献   

6.
The objective of this study was to assess the possible impact of deep well disposal operations, conducted between 1958 and 1974, on the ground water quality in a shallow fresh water aquifer beneath Sarnia, Ontario, Canada. Because of the breakout of formation fluids in Sarnia and Port Huron, Michigan, in the early 1970s, it had been hypothesized that liquid waste from the disposal zone in bedrock had leaked through numerous abandoned oil, gas, and salt wells in the area up to the shallow fresh water aquifer and from there to the surface.
A monitoring well network of 29 5cm (2 inch) diameter piezometers was established in the thin sand and shale aquifer system, which exists between 30 and 70m (100 and 230 feet) below ground surface. In addition, a 300m (1000 foot) deep borehole was drilled and instrumented with a Westbay multilevel casing, which permitted sampling of the disposal zone.
Ground water samples from the shallow monitoring wells and the Westbay multilevel casing were analyzed for volatiles by GC/MS. Those volatile aromatics that were conspicuously present in the deep disposal zone, e.g., ethyl toluenes and trimethyl benzene, were not detected in the shallow monitoring wells. Thus, if contaminants from the disposal zone did indeed migrate to the shallow aquifer, contamination was not widespread and probably consisted mostly of displaced chloride-rich formation waters.  相似文献   

7.
The city of St. Petersburg has been testing subsurface injection of treated sewage into the Floridan aquifer as a means of eliminating discharge of sewage to surface waters and as a means of storing treated sewage for future non-potable reuse. The injection zone originally contained native saline ground water that was similar in composition to sea water. The zone has a transmissivity of about 1.2 X 106 feet squared per day (ft2/d) and is within the lower part of the Floridan aquifer. Treated sewage that had a mean chloride concentration of 170 milligrams per liter (mg/1) was injected through a single well for 12 months at a mean rate of 4.7 X 105 cubic feet per day (ft3/d). The volume of water injected during the year was 1.7 X 108 cubic feet. Pressure buildup at the end of one year ranged from less than 0.1 to as much as 2.4 pounds per square inch (lb/in2) in observation wells at the site. Pressure buildup in wells open to the upper part of the injection zone was related to buoyant lift acting on the mixed water in the injection zone in addition to subsurface injection through the injection well. Calculations of the vertical component of pore velocity in the semiconfining bed underlying the shallowest permeable zone of the Floridan aquifer indicate upward movement of native water. This is consistent with the 200- to 600-mg/l increase in chloride concentration observed in water from the shallowest permeable zone during the test.  相似文献   

8.
Ground water temperatures in the fractured volcanic aquifer near Yucca Mountain, Nevada, have previously been shown to have significant spatial variability with regions of elevated temperatures coinciding roughly with near-vertical north-south trending faults. Using insights gained from one-dimensional models, previous investigators have suggested upwelling along faults from an underlying aquifer as a likely explanation for this ground water temperature pattern. Using a three-dimensional coupled flow and heat-transport model, we show that the thermal high coinciding with the Paintbrush fault zone can be explained without significant upwelling from the underlying aquifer. Instead, the thermal anomaly is consistent with thermal conduction enhanced slightly by vertical ground water movement within the volcanic aquifer sequence. If more than approximately 400 m3/day of water enters the volcanic aquifer from below along a 10 km fault zone, the calculated temperatures at the water table are significantly greater than the measured temperatures. These results illustrate the potential limitations in using one-dimensional models to interpret ground water temperature data, and underscore the value in combining temperature data with fully coupled three-dimensional simulations.  相似文献   

9.
Surface water is a scarce resource in Namibia with about sixty percent of Namibia's population dependent on groundwater for drinking purposes. With increasing population, the country faces water challenges and thus groundwater resources need to be managed properly. One important aspect of Integrated Water Resources Management is the protection of water resources, including protection of groundwater from contamination and over-exploitation. This study explores vulnerability mapping as a basic tool for protecting groundwater resources from pollution. It estimates groundwater vulnerability to pollution in the upper Niipele sub-basin of the Cuvelai-Etosha in Northern Namibia using the DRASTIC index. The DRASTIC index uses GIS to estimate groundwater vulnerability by overlaying different spatially referenced hydrogeological parameters that affect groundwater contamination. The study assesses the discontinuous perched aquifer (KDP) and the Ohangwena multi-layered aquifer 1 (KOH-1). For perched aquifers, point data was regionalized by a hydrotope approach whereas for KOH-1 aquifer, inverse distance weighting was used. The hydrotope approach categorized different parts of the hydrogeological system with similar properties into five hydrotopes. The result suggests that the discontinuous perched aquifers are more vulnerable than Ohangwena multi-layered aquifer 1. This implies that vulnerability increases with decreasing depth to water table because contaminants have short travel time to reach the aquifer when they are introduced on land surface. The nitrate concentration ranges between 2 and 288 mg/l in perched aquifers while in Ohangwena multi-layered aquifer 1, it ranges between 1 and 133 mg/l. It was observed that perched aquifers have high nitrate concentrations than Ohangwena 1 aquifer, which correlates well with the vulnerability results.  相似文献   

10.
Design Screening Tools for Passive Funnel and Gate Systems   总被引:1,自引:0,他引:1  
The funnel and gate remediation concept (Star and Cherry 1993) represents a promising, yet relatively under-developed, technology for the passive control and in situ remediation of contaminated ground water. Effective design and implementation of such a system may, however, prove difficult under conditions of large or unpredictable variations in contaminant migration or ground water flow.
Numerical modeling of two-dimensional ground water flow has been used to predict the hydraulic performance of passive, straight, or winged funnel and gate configurations over a range of hydrogeologic and ambient ground water flow conditions. The results of these analyses were used to construct generic correlation diagrams relating upstream capture zone or gale through put to the barrier, gale, and aquifer characteristics. These diagrams serve as useful screening tools to (1) quantitatively estimate the capture zone of pre-determined funnel and gale configurations, or (2) develop preliminary funnel and gale designs that will yield a desired capture zone, independent of aquifer characteristics.  相似文献   

11.
The delineation of well capture zones is a basic component of ground water protection. The conventional methodology for capture zone delineation is backward advective particle tracking, often applied under the assumption of a two-dimensional aquifer. The suitability of the conventional approach for complex heterogeneous multi-aquifer systems was investigated, using the Waterloo Moraine aquifer system as an example. It was found that the conventional approach produces irregular particle tracks that require judgment to interpret in a meaningful way, and it can raise questions that may affect the credibility of the capture zone delineation. As an alternative, the potentially powerful but little-used backward-in-time advective-dispersive transport approach was investigated. A key advantage of this approach is its capability to represent local heterogeneities through the dispersion term. The dispersion process has a natural smoothing effect that results in unambiguous capture zones without the need for interpretation, thus enhancing credibility. The question of capture zone validation is also addressed. The meaning of a three-dimensional capture zone is considered, and it is shown that a fully three-dimensional representation of the system is crucial for valid results. The distinction between the maximum extent capture zone and the surface capture zone is also explained. In the case of complex heterogeneous systems, advective particle tracking can be used as an initial screening tool, whereas the more realistic backward-transport modeling approach can be used for final capture-zone delineation.  相似文献   

12.
Neat ethanol (75.7 L) was released into the upper capillary zone in a continuous-flow, sand-packed aquifer tank (8.2 m3) with an average seepage velocity of 0.75 m/day. This model aquifer system contained a residual nonaqueous phase liquid (NAPL) that extended from the capillary zone to 10 cm below the water table. Maximum aqueous concentrations of ethanol were 20% v/v in the capillary zone and 0.08% in the saturated zone at 25 and 30 cm downgradient from the emplaced NAPL source, respectively. A bench-scale release experiment was also conducted for a similar size spill (scaled to the plan area). The concentrations of ethanol in ground water for both the bench- and pilot-scale experiments were consistent with advective–dispersive limited mass transfer from the capillary to the saturated zone. Concentrations of monoaromatic hydrocarbons and isooctane increased in the pore water of the capillary zone as a result of both redistribution of residual NAPL (confirmed by visualization) and enhanced hydrocarbon dissolution due to the cosolvent effect exerted by ethanol. In the tank experiment, higher hydrocarbon concentrations in ground water were also attributed to decreased hydrocarbon biodegradation activity caused by preferential microbial utilization of ethanol and the resulting depletion of oxygen. These results infer that spills of highly concentrated ethanol will be largely confined to the capillary zone due to its buoyancy, and ethanol concentrations in near-source zone ground water will be controlled by mass transfer limitations and hydrologic conditions. Furthermore, highly concentrated ethanol releases onto pre-existing NAPL will likely exacerbate impacts to ground water, due to NAPL mobilization and dissolution, and decreased bioattenuation of hydrocarbons.  相似文献   

13.
The area under study covers 3500 km2 in the upstream part of the closed catchment basin of the salt crust of Uyuni. This crust is a remnant of the saline Lake Tauca, which covered the area about 15,000 years ago. In the downstream part of the aquifer, the Cl concentration of ground water and Cl content in the unsaturated zone exceed 20 meq/L and 18 kg/m2, respectively. With the present hydrological conditions under semiarid conditions, the ground water residence time in the study area exceeds 3000 years. Transient simulations over 11,000 years were made using initial conditions as the retreat of Lake Tauca and taking into account a low recharge during the arid mid-Holocene period. The modeling simulates ground water flow, Cl transport, and ground water residence time. It includes the evaporation from the aquifer that leads to the accumulation of chloride in the unsaturated zone. Results of the modeling are consistent with the observations if it is assumed that the Cl previously accumulated in the unsaturated zone was flushed back into the aquifer around 2000 years B.P., contemporaneously with the end of the arid period.  相似文献   

14.
This study tests the feasibility of an aquifer remediation concept proposed by Gvirtzman and Gorelick (1992) that involves the removal of volatile organic compounds (VOCs) dissolved in ground water. The principal is 10 inject air into a well, creating airlift pumping, which is used as a means of in-well vapor stripping. The partially treated water is diverted away from the well and infiltrates back to the water table, thus allowing remediation of a larger aquifer volume.
A remediation well prototype, constructed in a laboratory aquifer model, was used to demonstrate the processes involved. The removal rates of trichloroethylene, toluene, and chloroform were monitored using eight triple-level observation wells. The continuous decrease of VOC concentrations during the short-term experiment has yielded macroscopic evidence that the process offers some promise. It was found that the flow field in the saturated zone. involving the continuous water circulation between the pumping well and the recharging area, caused temporal and spatial variation in remediation efficiency.  相似文献   

15.
Abstract

An analytical solution is developed to delineate the capture zone of a pumping well in an aquifer with a regional flow perpendicular to a stream, assuming a leaky layer between the stream and the aquifer. Three different scenarios are considered for different pumping rates. At low pumping rates, the capture zone boundary will be completely contained in the aquifer. At medium pumping rates, the tip of the capture zone boundary will intrude into the leaky layer. Under these two scenarios, all the pumped water is supplied from the regional groundwater flow in the aquifer. At high pumping rates, however, the capture zone boundary intersects the stream and pumped water is supplied from both the aquifer and the stream. The two critical pumping rates which separate these three scenarios, as well as the proportion of pumped water from the stream and the aquifer, are determined for different hydraulic settings.

Editor D. Koutsoyiannis; Associate editor A. Koussis

Citation Asadi-Aghbolaghi, M., Rakhshandehroo, G.R., and Kompani-Zare, M., 2013. An analytical approach to capture zone delineation for a well near a stream with a leaky layer. Hydrological Sciences Journal, 58 (8), 1813–1823.  相似文献   

16.
At a study site in the midwestern United States, multiple-completion wells demonstrated that a vertical hydraulic gradient was responsible for the contamination pattern exhibited by chlorinated solvent plumes. The typical pattern consisted of little or no contamination in the upper portion of the aquifer with concentrations increasing with depth. When ground water contamination was discovered in an unexpected portion of the site, water level elevations and contaminant distribution data obtained from multiple-completion wells resulted in identification of the source location. The well eventually determined to be located in the source area displayed contaminant levels much higher in the upper zone of the aquifer — the opposite contamination pattern of other on-site wells. Such results indicated that the spill had occurred near this location and that solvent residing along the capillary fringe was continuing to contaminate the aquifer.  相似文献   

17.
Comparative study of methods for WHPA delineation   总被引:3,自引:0,他引:3  
Human activities, whether agricultural, industrial, commercial, or domestic, can contribute to ground water quality deterioration. In order to protect the ground water exploited by a production well, it is essential to develop a good knowledge of the flow system and to adequately delineate the area surrounding the well within which potential contamination sources should be managed. Many methods have been developed to delineate such a wellhead protection area (WHPA). The integration of more information on the geologic and hydrogeologic characteristics of the study area increases the precision of any given WHPA delineation method. From a practical point of view, the WHPA delineation methods allowing the simplest and least expensive integration of the available information should be favored. This paper presents a comparative study in which nine different WHPA delineation methods were applied to a well and a spring in an unconfined granular aquifer and to a well in a confined highly fractured rock aquifer. These methods range from simple approaches to complex computer models. Hydrogeological mapping and numerical modeling with MODFLOW-MODPATH were used as reference methods to respectively compare the delineation of the zone of contribution and the zone of travel obtained from the various WHPA methods. Although applied to simple ground water flow systems, these methods provided a relatively wide range of results. To allow a realistic delineation of the WHPA in aquifers of variable geometry, a WHPA delineation method should ensure a water balance and include observed or calculated regional flow characteristics.  相似文献   

18.
Geochemical data indicate that the Springfield Plateau aquifer, a carbonate aquifer of the Ozark Plateaus Province in central USA, has two distinct hydrochemical zones. Within each hydrochemical zone, water from springs is geochemically and isotopically different than water from wells. Geochemical data indicate that spring water generally interacts less with the surrounding rock and has a shorter residence time, probably as a result of flowing along discrete fractures and solution openings, than water from wells. Water type throughout most of the aquifer was calcium bicarbonate, indicating that carbonate‐rock dissolution is the primary geochemical process occurring in the aquifer. Concentrations of calcium, bicarbonate, dissolved oxygen and tritium indicate that most ground water in the aquifer recharged rapidly and is relatively young (less than 40 years). In general, field‐measured properties, concentrations of many chemical constituents, and calcite saturation indices were greater in samples from the northern part of the aquifer (hydrochemical zone A) than in samples from the southern part of the aquifer (hydrochemical zone B). Factors affecting differences in the geochemical composition of ground water between the two zones are difficult to identify, but could be related to differences in chert content and possibly primary porosity, solubility of the limestone, and amount and type of cementation between zone A than in zone B. In addition, specific conductance, pH, alkalinity, concentrations of many chemical constituents and calcite saturation indices were greater in samples from wells than in samples from springs in each hydrochemical zone. In contrast, concentrations of dissolved oxygen, nitrite plus nitrate, and chloride generally were greater in samples from springs than in samples from wells. Water from springs generally flows rapidly through large conduits with minimum water–rock interactions. Water from wells flow through small fractures, which restrict flow and increase water–rock interactions. As a result, springs tend to be more susceptible to surface contamination than wells. The results of this study have important implications for the geochemical and hydrogeological processes of similar carbonate aquifers in other geographical locations. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

19.
Recharge areas of spring systems can be hard to identify, but they can be critically important for protection of a spring resource. A recharge area for a spring complex in southern Wisconsin was delineated using a variety of complementary techniques. A telescopic mesh refinement (TMR) model was constructed from an existing regional-scale ground water flow model. This TMR model was formally optimized using parameter estimation techniques; the optimized "best fit" to measured heads and fluxes was obtained by using a horizontal hydraulic conductivity 200% larger than the original regional model for the upper bedrock aquifer and 80% smaller for the lower bedrock aquifer. The uncertainty in hydraulic conductivity was formally considered using a stochastic Monte Carlo approach. Two-hundred model runs used uniformly distributed, randomly sampled, horizontal hydraulic conductivity values within the range given by the TMR optimized values and the previously constructed regional model. A probability distribution of particles captured by the spring, or a "probabilistic capture zone," was calculated from the realistic Monte Carlo results (136 runs of 200). In addition to portions of the local surface watershed, the capture zone encompassed areas outside of the watershed--demonstrating that the ground watershed and surface watershed do not coincide. Analysis of water collected from the site identified relatively large contrasts in chemistry, even for springs within 15 m of one another. The differences showed a distinct gradation from Ordovician-carbonate-dominated water in western spring vents to Cambrian-sandstone-influenced water in eastern spring vents. The difference in chemistry was attributed to distinctive bedrock geology as demonstrated by overlaying the capture zone derived from numerical modeling over a bedrock geology map for the area. This finding gives additional confidence to the capture zone calculated by modeling.  相似文献   

20.
Steady flow to a well near a stream with a leaky bed   总被引:2,自引:0,他引:2  
Bakker M  Anderson EI 《Ground water》2003,41(6):833-840
We present an explicit analytic solution for steady, two-dimensional ground water flow to a well near a leaky streambed that penetrates the aquifer partially. Leakage from the stream is approximated as occurring along the centerline of the stream. The problem domain is infinite and pumping on one side of the stream induces flow on the other side. The solution includes the effects of uniform flow in the far field and a sloping hydraulic head in the stream. We use the solution to investigate the interaction between ground water and surface water in the stream, the effects of pumping on the opposite side of the stream, and the effects of the leaky streambed on the capture zone envelope of the well. We develop a relationship between parameters such that the pumping well will not capture water from the stream, or from the opposite side of the stream. When the discharge of the well is large enough to capture water from the stream, the shape of the capture zone envelope depends on flow conditions on the side of the stream opposite the well.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号