1.
The possibility of using a multi-stage pendulum mass damper(MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part Ⅰ of this work.In this paper,the performance of the MSPMD for reducing bridge tower vibration is studied experimentally.A MSPMD model and a tower model of the bridge with geometry scaling of 1100 were designed and manufactured.Calibration of the MSPMD model with different wire lengths is conducted to verify the analytical model of the damper.A series of tests for the uncontrolled freestanding tower,tower with cables,and tower with MSPMD model are then performed under harmonic and white noise excitations.The experimental results show that the responses of the tower model significantly decrease with the installation of the MSPMD model,which demonstrates the effectiveness of the MSPMD to mitigate the vibration of the bridge tower.  相似文献   

2.
The possibility of using a multi-stage pendulum mass damper (MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part I of this work. In this paper, the performance of the MSPMD for reducing bridge tower vibration is studied experimentally. A MSPMD model and a tower model of the bridge with geometry scaling of 1:100 were designed and manufactured. Calibration of the MSPMD model with different wire lengths is conducted to verify the analytical model of the damper. A series of tests for the uncontrolled freestanding tower, tower with cables, and tower with MSPMD model are then performed under harmonic and white noise excitations. The experimental results show that the responses of the tower model signif icantly decrease with the installation of the MSPMD model, which demonstrates the effectiveness of the MSPMD to mitigate the vibration of the bridge tower.  相似文献   

3.
As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years.To fulfill this special requirement imposed by current seismic design codes,reinforcement ratios in the bridge towers have to be kept significantly higher than if limited ductility behavior of the tower is allowed.In addition,since the foundation capacity is closely related to the moment and shear capacities of the bridge tower,a large increase in bridge construction cost for elastically designed cable-stayed bridge is inevitable.To further investigate the possibility of limited ductility bridge tower design strategies,a new 1/20-scale cable-stayed bridge model with H-shaped bridge towers designed according to strong strut-weak tower column design was tested.The shake table experimental results are compared with a previous strong tower column-weak strut designed full bridge model.A comparison of the results show that ductility design with plastic hinges located on tower columns,i.e.,strong strut-weak tower column design,is another effective seismic design strategy that results in only small residual displacement at the top of the tower column,even under very severe earthquake excitations.  相似文献   

4.
In this paper, a semiactive variable stiffness (SVS) device is used to decrease cable oscillations caused by parametric excitation, and the equation of motion of the parametric vibration of the cable with this SVS device is presented. The ON/OFF control algorithm is used to operate the SVS control device. The vibration response of the cable with the SVS device is numerically studied for a variety of additional stiffness combinations in both the frequency and time domains and for both parametric and classical resonance vibration conditions. The numerical studies further consider the cable sag effect. From the numerical results, it is shown that the SVS device effectively suppresses the cable resonance vibration response, and as the stiffness of the device increases, the device achieves greater suppression of vibration. Moreover, it was shown that the SVS device increases the critical axial displacement of the excitation under cable parametric vibration conditions.  相似文献   

5.
The spatial variability of input ground motion at supporting foundations plays a key role in the structural response of cable-stayed bridges (CSBs); therefore, spatial variation effects should be included in the analysis and design of effective vibration control systems. The control of CSBs represents a challenging and unique problem, with many complexities in modeling, control design and implementation, since the control system should be designed not only to mitigate the dynamic component of the structural response but also to counteract the effects of the pseudo-static component of the response. The spatial variability effects on the feasibility and efficiency of seismic control systems for the vibration control of CSBs are investigated in this paper. The assumption of uniform earthquake motion along the entire bridge may result in quantitative and qualitative differences in seismic response as compared with those produced by uniform motion at all supports. A systematic comparison of passive and active system performance in reducing the structural responses is performed, focusing on the effect of the spatially varying earthquake ground motion on the seismic response of a benchmark CSB model with different control strategies, and demonstrates the importance of accounting for the spatial variability of excitations.  相似文献   

6.
A wind turbine system equipped with a tuned liquid column damper(TLCD) is comprehensively studied via shaking table tests using a 1/13-scaled model. The effects of wind and wave actions are considered by inputting responseequivalent accelerations on the shaking table. The test results show that the control effect of the TLCD system is significant in reducing the responses under both wind-wave equivalent loads and ground motions, but obviously varies for different inputs. Further, a blade-hub-tower integrated numerical model for the wind turbine system is established. The model is capable of considering the rotational effect of blades by combining Kane’s equation with the finite element method. The responses of the wind tower equipped with TLCD devices are numerically obtained and compared to the test results, showing that under both controlled and uncontrolled conditions with and without blades’ rotation, the corresponding responses exhibit good agreement. This demonstrates that the proposed numerical model performs well in capturing the wind-wave coupled response of the offshore wind turbine systems under control. Both numerical and experimental results show that the TLCD system can significantly reduce the structural response and thus improve the safety and serviceability of the offshore wind turbine tower systems. Additional issues that require further study are discussed.  相似文献   

7.
Combining the computational fluid dynamics-based numerical simulation with the forced vibration technique for extraction of aerodynamic derivatives, an approach for calculating the aerodynamic derivatives and the critical flutter wind speed for long-span bridges is presented in this paper. The RNG k-ε turbulent model is introduced to establish the governing equations, including the continuity equation and the Navier-Stokes equations, for solving the wind flow field around a two-dimensional bridge section. To illustrate the effectiveness and accuracy of the proposed approach, a simple application to the Hume Bridge in China is provided, and the numerical results show that the aerodynamic derivatives and the critical flutter wind speed obtained agree well with the wind tunnel test results.  相似文献   

8.
A numerical solution based on the Steffensen stable point iterative method is proposed to resolve the transcendental frequency equation of a stay cable-damper system. The frequency equation, which considers clamped supports and fl exural rigidity of the cable, is intended to investigate the infl uence of the parameters of the cable damper system on its dynamic characteristics. Two factors involved in the design and construction phases, the damping coeffi cient induced by external dampers and the cable tension, are the focus of this study. Their impact on modal frequencies and damping ratios in these two phases of cable-damper systems are investigated by resolving the equation with the proposed solution. It is shown that the damping coeffi cient and cable tension exert more noticeable effects on the modal damping ratios than on the modal frequencies of stay cable-damper systems, and the two factors can serve as design variables in the design phase and as adjustment factors in the construction phase. On the basis of the results, a roadmap for system-level optimal design of stay cable-damper systems that can achieve global optimal vibration suppression for the entire bridge is proposed and discussed.  相似文献   

9.
The rigid central buckle employed in the Runyang Suspension Bridge (RSB) was the first time it was used in a suspension bridge in China. By using a spectral representation method and FFT technique combined with measured data,a 3D fluctuating wind field considering the tower wind effect is simulated. A novel FE model for buffeting analysis is then presented,in which a specific user-defined Matrix27 element in ANSYS is employed to simulate the aeroelastic forces and its stiffness or damping matrices are parameterized by wind velocity and vibration frequency. A nonlinear time history analysis is carried out to study the influence of the rigid central buckle on the wind-induced buffeting response of a long-span suspension bridge. The results can be used as a reference for wind resistance design of long-span suspension bridges with a rigid central buckle in the future.  相似文献   

10.
Strong near-fault ground motion, usually caused by the fault-rupture and characterized by a pulse-like velocity- wave form, often causes dramatic instantaneous seismic energy (Jadhav and Jangid 2006). Some reinforced concrete (RC) bridge columns, even those built according to ductile design principles, were damaged in the 1999 Chi-Chi earthquake. Thus, it is very important to evaluate the seismic response of a RC bridge column to improve its seismic design and prevent future damage. Nonlinear time history analysis using step-by-step integration is capable of tracing the dynamic response of a structure during the entire vibration period and is able to accommodate the pulsing wave form. However, the accuracy of the numerical results is very sensitive to the modeling of the nonlinear load-deformation relationship of the structural member. FEMA 273 and ATC-40 provide the modeling parameters for structural nonlinear analyses of RC beams and RC columns. They use three parameters to define the plastic rotation angles and a residual strength ratio to describe the nonlinear load- deformation relationship of an RC member. Structural nonlinear analyses are performed based on these parameters. This method provides a convenient way to obtain the nonlinear seismic responses of RC structures. However, the accuracy of the numerical solutions might be further improved. For this purpose, results from a previous study on modeling of the static pushover analyses for RC bridge columns (Sung et al. 2005) is adopted for the nonlinear time history analysis presented herein to evaluate the structural responses excited by a near-fault ground motion. To ensure the reliability of this approach, the numerical results were compared to experimental results. The results confirm that the proposed approach is valid.  相似文献   

11.
The lack of knowledge concerning modelling existing buildings leads to significant variability in fragility curves for single or grouped existing buildings. This study aims to investigate the uncertainties of fragility curves, with special consideration of the single-building sigma. Experimental data and simplified models are applied to the BRD tower in Bucharest, Romania, a RC building with permanent instrumentation. A three-step methodology is applied: (1) adjustment of a linear MDOF model for experimental modal analysis using a Timoshenko beam model and based on Anderson's criteria, (2) computation of the structure's response to a large set of accelerograms simulated by SIMQKE software, considering twelve ground motion parameters as intensity measurements (IM), and (3) construction of the fragility curves by comparing numerical interstory drift with the threshold criteria provided by the Hazus methodology for the slight damage state. By introducing experimental data into the model, uncertainty is reduced to 0.02 considering Sd ) as seismic intensity IM and uncertainty related to the model is assessed at 0.03. These values must be compared with the total uncertainty value of around 0.7 provided by the Hazus methodology.  相似文献   

12.
Multi-axial perfectly matched layer(M-PML), known to have lost the perfect-matching property owing to multi-axial coordinate stretching, has been numerically validated to be long-time stable and it is thus used extensively in linear anisotropic wave simulation and in isotropic cases where the PML becomes unstable. We are concerned with the construction of the M-PML for anisotropic wave simulation based on a second order wave equation implemented with the displacement-based numerical method. We a...  相似文献   

13.
The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing the control effectiveness in mega-frame buildings. In this paper, a dynamic equation and method to assemble parameter matrixes for a mega-sub controlled structure under random wind loads is presented. Semi-active control using magnetorheological dampers for the MSCS under random wind loads is investigated, and is compared with a corresponding system without dampers. A parametric study of the relative stiffness ratio and relative mass ratio between the mega-frame and the substructures, as well as the additional column stiffness ratio that influences the response control effectiveness of the MSCS, is discussed. The studies reveal, for the first time, that different control mechanisms exist. The results indicate that the proposed structure employing semi-active control can offer an effective control mechanism. Guidelines for selecting parameters are provided based on the analytical study.  相似文献   

14.
This study investigates the effectiveness of the non-smooth semi-active control algorithm on suppressing the vibration performance of a building structure subjected to seismic waves. According to the Lyapunov stability theory, it has bene proven that the non-smooth semi-active control algorithm can achieve a finite-time stability of the vibration relative to the isolation layer of a building structure. Through numerical simulation of two buildings with different parameters subjected to the input of a seismic wave, the vibration conditions of passive control, LQR semi-active control and non-smooth semiactive control are compared and analyzed. The simulation results show that the non-smooth semi-active control algorithm has a better robustness and effectiveness in restraining the impact of earthquakes on the structure.  相似文献   

15.
To enable rapid recovery of a steel bridge column after an earthquake, a novel tubular-section steel bridge column equipped with low-yield-point(LYP) steel tubular plates in the root replaceable pier is proposed. For the purpose of discussing the seismic behavior of the novel steel bridge column, quasi-static tests and finite element simulation analyses of the specimens were carried out. The effects of parameters such as the axial compression ratio, eccentricity, and thickness and material stren...  相似文献   

16.
Various methods to control scour around bridge piers have been proposed.In the present study the application of cable or collar and a combination of cable and collar were examined experimentally,as countermeasures against local scouring at a smooth circular bridge pier,close to threshold flow conditions of initiation of uniform sediment motion.The results show that the simultaneous use of cable and collar has high efficiency in reducing the scour depth.The best configuration was found for a cable-pier diameter ratio of 0.15 and thread angle of 15°,in which the scour depth in upstream of the pier reduced to about 53%.In the case of a pier protected with cable and collar the scouring postponed more than pier protected with collar and the rate of scouring is less than in pier protected with collar.These advantages can reduce the risk of pier failure when the duration of flood is short. The results indicate that the scour reduction increases as the cable diameter increased and the thread angle decreased.  相似文献   

17.
Seismic hazard assessment based on urban active faults can provide scientific bases for city planning and projectconstruction,while numerical simulation of strong ground motion is an important method for seismic hazard pre-diction and assessment.A 3-D physical model in conformity with real strata configuration of(mainly)the Quater-nary is a prerequisite to ensure the reliability of the simulation results.In this paper,we give a detailed account ofthe technical scheme and process for creating a 3-D physical model in Kunming basin.The data used are synthe-sized from seismogeological data,borehole data,topographic data,digital elevation mode(DEM)data,seismicexploration results and wave velocity measurements.Stratigraphic division is based mainly on shear wave velocity,with strata sequence taken into consideration.The model construction is finally accomplished with ArcGIS andmany relevant programming techniques via layer-by-layer stacking(in depth direction)of the adjacent mediuminterfaces(meshes).Meanwhile,a database of 3-D physical models is set up,which provides model data and pa-rameters for strong ground motion simulation.Some processing methods and significant issues are also addressedin the paper in accordance with different types of exploration and experimental data.  相似文献   

18.
In this paper, a wavelet-fi ltered genetic-neuro-fuzzy(WGNF) control system design framework for response control of a highway bridge under various earthquake loads is discussed. The WGNF controller is developed by combining fuzzy logic, discrete wavelet transform, genetic algorithms, and neural networks for use as a control algorithm. To evaluate the performance of the WGNF algorithm, it is tested on a highway bridge equipped with hydraulic actuators. It controls the actuators installed on the abutments of the highway bridge structure. Various earthquakes used as input signals include an artifi cial earthquake, the El-Centro, Kobe, North Palm Springs, Turkey Bolu, Chi-Chi, and Northridge earthquakes. It is proved that the WGNF control system is effective in mitigating the vibration of the highway bridge under a variety of seismic excitation.  相似文献   

19.
In this paper, a numerical method for correlation sensitivity analysis of a nonlinear random vibration system is presented. Based on the first passage failure model, the probability perturbation method is employed to determine the statistical characteristics of failure modes and the correlation between them. The sensitivity of correlation between failure modes with respect to random parameters characterizing the uncertainty of the hysteretic loop is discussed. In a numerical example, a two-DOF shear structure with uncertain hysteretic restoring force is considered. The statistical characteristics of response, failure modes and the sensitivity of random hysteretic loop parameters are provided, and also compared with a Monte Carlo simulation.  相似文献   

20.
The objective of this study is to develop an analytical methodology to evaluate the effectiveness ofvibro stone column (S. C.) and dynamic compaction (D.C.) techniques supplemented with wick drains to densify and mitigate liquethctionin saturated sands and non-plastic silty soils. It includes the following: (i) develop numerical models to simulate and analyze soil densification during S.C. installation and D.C. process, and (ii) identify parameters controlling post-improvement soil density in both cases, and (iii) develop design guidelines for densification of silty soils using the above techniques. An analytical procedure was developed and used to simulate soil response during S.C. and D.C. installations, and the results were compared with available case history data. Important construction design parameters and soil properties that affect the effectiveness of these techniques, and construction design choices suitable for sands and non-plastic silty soils were identified. The methodology is expected to advance the use of S.C. and DC. in silty soils reducing the reliance on expensive field trials as a design tool. The ultimate outcome of this research will be design charts and design guidelines for using composite stone columns and composite dynamic compaction techniques in liquefaction mitigation of saturated silty soils.  相似文献   