首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
To ensure the high quality of ultra‐precision products such as semiconductors and optical microscopes, high‐tech equipment used to make these products requires a normal working environment with extremely limited vibration. Some of high‐tech industry centres are also located in seismic zones: the safety of high‐tech equipment during an earthquake event becomes a critical issue. It is thus imperative to find an effective way to ensure the functionality of high‐tech equipment against microvibration and to protect high‐tech equipment from damage when earthquake events occur. This paper explores the possibility of using a hybrid platform to mitigate two types of vibration. The hybrid platform, on which high‐tech equipment is installed, is designed to work as a passive isolation platform to abate mainly acceleration response of high‐tech equipment during an earthquake and to function as an actively controlled platform to reduce mainly velocity response of high‐tech equipment under normal working condition. To examine the performance of the hybrid platform, the analytical model of a coupled hybrid platform and building system incorporating with magnetostrictive actuators is established. The simulation results obtained by applying the analytical model to a high‐tech facility indicate that the proposed hybrid platform is feasible and effective. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

2.
This paper presents an experimental study, while a companion paper addresses an analytical study, to explore the possibility of using a hybrid platform to mitigate vibration of a batch of high‐tech equipment installed in a building subject to nearby traffic‐induced ground motion. A three‐storey building model and a hybrid platform model are designed and manufactured. The hybrid platform is mounted on the building floor through passive mounts composed of leaf springs and oil dampers and controlled actively by an electromagnetic actuator with velocity feedback control strategy. The passive mounts are designed in such a way that the stiffness and damping ratio of the platform can be changed. A series of shaking table tests are then performed on the building model without the platform, with the passive platform of different parameters, and with the hybrid platform. The experimental results demonstrate that the hybrid platform is very effective in reducing the velocity response of a batch of high‐tech equipment in the building subject to nearby traffic‐induced ground motion if dynamic properties of the platform and control feedback gain are selected appropriately. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
High‐tech equipments engaged in the production of ultra‐precision products have very stringent vibration criteria for their functionality in normal operation conditions and their safety during an earthquake. Most previous investigations were based on simplified planar models of building structures, despite the fact that real ground motions and structures are always three‐dimensional. This paper hence presents a three‐dimensional analytical study of a hybrid platform on which high‐tech equipments are mounted for their vibration mitigation. The design methodology of the hybrid platform proposed in this study is based on dual‐level performance objectives for high‐tech equipments: safety against seismic hazard and functionality against traffic‐induced microvibration. The passive devices (represented by springs and viscous dampers) and the active actuators are designed, respectively, to meet vibration criteria corresponding to safety level and functionality level. A prototype three‐story building with high‐tech equipments installed on the second floor is selected in the case study to evaluate the effectiveness of the hybrid platform. The optimal location of the platform on the second building floor is determined during the design procedure in terms of the minimal H 2 cost function of absolute velocity response. The simulation of the coupled actuator‐platform‐building system subjected to three‐dimensional ground motions indicates that the optimally designed hybrid platform can well achieve the dual target performance and effectively mitigate vibration at both ground motion levels. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
The experimental results of using a hybrid platform to mitigate vibration of a batch of high‐tech equipment installed in a building subject to nearby traffic‐induced ground motion have been presented and discussed in the companion paper. Based on the identified dynamic properties of both the building and the platform, this paper first establishes an analytical model for hybrid control of the building‐platform system subject to ground motion in terms of the absolute co‐ordinate to facilitate the absolute velocity feedback control strategy used in the experiment. The traffic‐induced ground motion used in the experiment is then employed as input to the analytical model to compute the dynamic response of the building‐platform system. The computed results are compared with the measured results, and the comparison is found to be satisfactory. Based on the verified analytical model, coupling effects between the building and platform are then investigated. A parametric study is finally conducted to further assess the performance of both passive and hybrid platforms at microvibration level. The analytical study shows that the dynamic interaction between the building and platform should be taken into consideration. The hybrid control is effective in reducing both velocity response and drift of the platform/high‐tech equipment at microvibration level with reasonable control force. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

5.
高科技厂房精密仪器工作平台的微振混合控制   总被引:2,自引:1,他引:1  
车辆运行过程中引起的竖向地面微幅振动是影响高科技厂房精密仪器正常运行的重要因素。本文采用隔振与主动控制相结合的混合控制系统,以高科技厂房及精密仪器工作平台的有限元动力方程为基础,采用子优化控制方法建立了高科技厂房及精密仪器工作平台的分析模型,探讨了车辆运行所引起的高科技厂房精密仪器工作平台竖向微幅振动的混合控制分析方法。一座典型的三层高科技厂房的算例分析表明,采用混合控制方法能够有效地减小高科技厂房精密仪器工作平台的竖向微幅振动。  相似文献   

6.
A hybrid control platform is investigated in this paper to mitigate microvibrations to a group of vibration-sensitive equipment installed in a microelectronics facility subject to nearby road vehicle-induced horizontal and vertical ground motions. The hybrid control platform, on which microelectronics equipment is installed, is mounted on a building floor through a series of passive mounts and controlled by hydraulic actuators in both horizontal and vertical directions. The control platform is an elastic body with significant bending modes of vibration, and a sub-optimal control algorithm is used to manipulate the hydraulic actuators with actuator dynamics included. The finite element model and the equations of motion of the coupled platform-building system are then established in the absolute coordinate to facilitate the feedback control and performance evaluation of the platform. The horizontal and vertical ground vibrations at the base of the building induced by nearby moving road vehicles are assumed to be stationary random processes. A typical three-story microelectronics building is selected as a case study. The case study shows that the vertical vibration of the microelectronics building is higher than the horizontal. The use of a hybrid control platform can effectively reduce both horizontal and vertical microvibrations of the microelectronics equipment to the level which satisfies the stringent microscale velocity requirement specified in the Bolt Beranek & Newman (BBN) criteria.  相似文献   

7.
Critical non‐structural equipments, including life‐saving equipment in hospitals, circuit breakers, computers, high technology instrumentations, etc., are vulnerable to strong earthquakes, and the failure of these equipments may result in a heavy economic loss. In this connection, innovative control systems and strategies are needed for their seismic protections. This paper presents the performance evaluation of passive and semi‐active control in the equipment isolation system for earthquake protection. Through shaking table tests of a 3‐story steel frame with equipment on the first floor, a magnetorheological (MR)‐damper together with a sliding friction pendulum isolation system is placed between the equipment and floor to reduce the vibration of the equipment. Various control algorithms are used for this semi‐active control studies, including the decentralized sliding mode control (DSMC) and LQR control. The passive‐on and passive‐off control of MR damper is used as a reference for the discussion on the control effectiveness. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
This paper presents the development, experimental testing, and numerical modelling of a new hybrid timber‐steel moment‐resisting connection that is designed to improve the seismic performance of mid‐rise heavy timber moment‐resisting frames (MRF). The connection detail incorporates specially designed replaceable steel links fastened to timber beams and columns using self‐tapping screws. Performance of the connection is verified through experimental testing of four 2/3 scale beam‐column connections. All 4 connection specimens met the acceptance criteria specified in the AISC 341‐10 provisions for steel moment frames and exhibit high strength, ductility, and energy dissipation capacity up to storey drifts exceeding 4%. All of the timber members and self‐tapping screw connections achieved their design objective, remaining entirely elastic throughout all tests and avoiding brittle modes of failure. To assess the global seismic performance of the newly developed connection in a mid‐rise building, a hybrid timber‐steel building using the proposed moment‐resisting connection is designed and modelled in OpenSees. To compare the seismic performance of the hybrid MRF with a conventional steel MRF, a prototype steel‐only building is also designed and modelled in OpenSees. The building models are subject to a suite of ground motions at design basis earthquake and maximum credible earthquake hazard levels using non‐linear time history analysis. Analytical results show that drifts and accelerations of the hybrid building are similar to a conventional steel building while the foundation forces are significantly reduced for the hybrid structure because of its lower seismic weight. The results of the experimental program and numerical analysis demonstrate the seismic performance of the proposed connection and the ability of the hybrid building to achieve comparable seismic performance to a conventional steel MRF.  相似文献   

9.
Structural vibration control using active or passive control strategy is a viable technology for enhancing structural functionality and safety against natural hazards such as strong earthquakes and high wind gusts. Both the active and passive control systems have their limitations. The passive control system has limited capability to control the structural response whereas the active control system depends on external power. The power requirement for active control of civil engineering structures is usually quite high. Thus, a hybrid control system is a viable solution to alleviate some of the limitations. In this paper a multi‐objective optimal design of a hybrid control system for seismically excited building structures has been proposed. A tuned mass damper (TMD) and an active mass driver (AMD) have been used as the passive and active control components of the hybrid control system, respectively. A fuzzy logic controller (FLC) has been used to drive the AMD as the FLC has inherent robustness and ability to handle the non‐linearities and uncertainties. The genetic algorithm has been used for the optimization of the control system. Peak acceleration and displacement responses non‐dimensionalized with respect to the uncontrolled peak acceleration and displacement responses, respectively, have been used as the two objectives of the multi‐objective optimization problem. The proposed design approach for an optimum hybrid mass damper (HMD) system, driven by FLC has been demonstrated with the help of a numerical example. It is shown that the optimum values of the design parameters of the hybrid control system can be determined without specifying the modes to be controlled. The proposed FLC driven HMD has been found to be very effective for vibration control of seismically excited buildings in comparison with the available results for the same example structure but with a different optimal absorber. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

10.
Sine sweep and earthquake excitation tests have been performed on a one-story spatial steel frame building equipped with two identical semi-active assemblies described and fully characterized in a companion paper. The tests allowed identifying and validating simple mathematical models of the building in its passive configurations as well as in semi-active operation according to an energy storing and suddenly dissipating algorithm. In order to eliminate or at least attenuate the detrimental effects of control delays due to adopted software, electronic apparatus and mechanical inertia of variable dampers' moving parts, a simple ‘sine-fit’ prediction method was conceived, evaluated and adopted in subsequent tests. It is shown that, with adequate anticipation of device operation, the selected control algorithm produces a satisfactory reduction of building response compared to that obtained in passive configurations, with overall system efficiency practically independent of the earthquake input and related only to the properties of the semi-active assembly. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

11.
This paper summarizes the relevant results of the design, construction, testing, and implementation of a nominal 120 kN magnetorheological damper developed to control a free‐plan tall building in Santiago, Chile, equipped with two 160‐ton tuned masses. Cyclic as well as hybrid simulation tests were performed on the prototype damper. Global building responses using measured MR properties showed good correlation with analytical estimations. Also, a proposed physical controller for the MR damper was validated through hybrid and building pull‐back tests. Its performance is essentially equivalent to that of an LQR controller, but the information needed in its implementation is considerably less. Pull‐back tests of 10 cm amplitude were performed on one mass along the flexible edge of the building and its response controlled using the passive and controlled modes of the MR damper. The MR damper was capable of controlling the TM displacements very effectively, as well as the simulated building response for different ground motions and harmonic excitation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
This paper presents a formulation for earthquake resistant design of optimum hybrid isolation systems for sensitive equipment protection. The hybrid system under consideration consists of laminated rubber bearings, viscodampers and a set of actuators which, grounded on the main structural system, deliver forces on the basement of the isolated substructure mounted on the main structural system. An integrated design procedure for the passive and active components of the isolation system is developed aiming at acceleration reduction under random excitation. Linear models are used for the isolated structure, the main structural system and the isolation system. Fractional derivative Maxwell elements are used to model the mechanical behaviour of the viscodampers. The active component of the isolation system applies forces proportional to the absolute velocity of the isolated piece of equipment. Constraints in the deformation capacity of the isolators as well as constraints in the capacity of the actuators are considered for the design of an optimal hybrid isolation system. Simple numerical examples are developed herein to illustrate the design procedure. The superiority of hybrid systems over passive systems in reducing acceleration response is demonstrated.  相似文献   

13.
Multi‐storey buildings made of cross‐laminated timber panels (X‐lam) are becoming a stronger and economically valid alternative in Europe compared with traditional masonry or concrete buildings. During the design process of these multi‐storey buildings, also their earthquake behaviour has to be addressed, especially in seismic‐prone areas such as Italy. However, limited knowledge on the seismic performance is available for this innovative massive timber product. On the basis of extensive testing series comprising monotonic and reversed cyclic tests on X‐lam panels, a pseudodynamic test on a one‐storey X‐lam specimen and 1D shaking table tests on a full‐scale three‐storey specimen, a full‐scale seven‐storey building was designed according to the European seismic standard Eurocode 8 and subjected to earthquake loading on a 3D shaking table. The building was designed with a preliminary action reduction factor of three that had been derived from the experimental results on the three‐storey building. The outcomes of this comprehensive research project called ‘SOFIE – Sistema Costruttivo Fiemme’ proved the suitability of multi‐storey X‐lam structures for earthquake‐prone regions. The buildings demonstrated self‐centring capabilities and high stiffness combined with sufficient ductility to avoid brittle failures. The tests provided useful information for the seismic design with force‐based methods as defined in Eurocode 8, that is, a preliminary experimentally based action reduction factor of three was confirmed. Valid, ductile joint assemblies were developed, and their importance for the energy dissipation in buildings with rigid X‐lam panels became evident. The seven‐storey building showed relatively high accelerations in the upper storeys, which could lead to secondary damage and which have to be addressed in future research. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
There has been a significant increase in the size of building structures in recent years. Huge structures such as high‐rise buildings and large‐domed stadiums require high‐performance structural control, including the use of high‐capacity dampers, especially in an earthquake‐prone country like Japan. The objective of the present study was the enhancement of both human and structural safety in such structures through the development of a rate‐dependent type of damper with a high damping capacity. Among the various available types of rate‐dependent dampers, the authors focused on the oil damper owing to its stable performance against long‐duration vibrations. The target maximum damping force was 6000 kN, which is higher than that of any existing oil damper utilized in building structures. The authors developed a novel concept for achieving this high capacity while maintaining the size of the damper within acceptable dimensions from an architectural point of view. The concept involves the use of multiple damper units that produce mechanically parallel damping forces spatially arranged in series. As a prototype, a 1500‐kN oil damper was fabricated by combining three 500‐kN dampers. The 1500‐kN prototype damper was conceived as a full‐scale prototype of a damper that is more slender than comparable commercially available dampers in Japan, and as a scaled model of the proposed 6000‐kN damper. Sinusoidal loading tests were conducted on the prototype damper using a frequency range of 0.1–1.5 Hz and a velocity range of 0.4–300 mm/s. The results confirmed that the damper produced the design damping forces. The results of earthquake loading tests also revealed that the damper exerted a stable damping force against a large earthquake and maintained its performance after the earthquake. The damper is particularly effective against earthquakes with long‐period components that could increase the temperature of a damper. This is afforded by its high heat capacity compared to conventional dampers. Considering that the proposed 6000‐kN damper will generate a damping force that is about 2–3 times that of the strongest conventional oil damper, existing manufacturer test machines would be inadequate for evaluating its full performance characteristics. To address this issue, the authors also propose a test method for evaluating the overall damping force. The method is premised on the fact that the characteristic feature of the proposed damper is its combination of multiple damper units. The overall performance is thus evaluated using the test results for the individual damper units while the other dampers are bypassed. This method was verified by the results of the abovementioned sinusoidal loading tests, with the error for the 1500‐kN prototype damper found to be less than 5%. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
This paper investigates the dynamic characteristics and seismic behavior of prefabricated steel stairs in a full‐scale five‐story building shake table test program. The test building was subjected to a suite of earthquake input motions and low‐amplitude white noise base excitations first, while the building was isolated at its base, and subsequently while it was fixed to the shake table platen. This paper presents the modal characteristics of the stairs identified using the data recorded from white noise base excitation tests as well as the physical and measured responses of the stairs from the earthquake tests. The observed damage to the stairs is categorized into three distinct damage states and is correlated with the interstory drift demands of the building. These shake table tests highlight the seismic vulnerability of modern designed stair systems and in particular identifies as a key research need the importance of improving the deformability of flight‐to‐building connections. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
三维立体可视化震情会商系统平台设计与实现   总被引:2,自引:1,他引:1  
随着政府和社会公众对建立现代震情会商系统的需求日益增强,本文尝试应用三维GIS技术和体绘制可视化方法,解决地震会商过程中的多源、海量地学数据的协同可视化问题.设计并实现了三维立体可视化会商系统平台,并在其上将汶川余震分布、数值模拟和华北精细地下三维速度结构等研究成果进行了集成测试.  相似文献   

17.
地震应急装备信息管理系统的设计与实现   总被引:1,自引:0,他引:1  
本文针对目前地震应急装备管理过程中存在的工作方法和技术手段相对落后、装备处置时效性差和维护成本大等问题,进行了基于C/S模式的地震应急装备信息管理系统架构,以地震应急装备库装备信息为数据基础,设计了查询装备库存、装备入库、出库、盘点、预警及统计管理等系统核心功能模块,并在此基础上应用PowerScript语言进行开发,用MySQL作为底层数据库实现了系统的各个功能模块。经测试应用表明,该系统不仅实现了应急装备的高效、智能化、科学化的管理,也保证了装备资源的安全性和使用时的高效性,使地震应急时装备分配效率得到很大提升,对于提高地震应急装备保障效率及推进相关的信息化建设有着重要的意义。  相似文献   

18.
三维隔震(振)支座的工程应用与现场测试   总被引:2,自引:0,他引:2  
首先介绍了一种新型三维隔震(振)支座,该支座由联接件、竖向隔振支座和水平隔震支座组成。竖向隔振支座和水平隔震支座具有较小刚度,采用该类型支座的隔震结构,其竖向基频和水平基频可远离地铁、铁路振动和地震的主频,从而实现竖向隔振和水平隔震作用。其次介绍了该三维隔震(振)支座在某一地铁平台上部结构中的应用情况,对该类型支座进行了竖向性能和水平性能试验。最后对三维隔震(振)结构与传统结构进行了地铁运行时结构振动的对比测试。测试结果表明:三维隔震(振)系统对振动的高频信号具有显著衰减效果。  相似文献   

19.
Velocity adjustable TMD and numerical simulation of seismic performance   总被引:2,自引:0,他引:2  
A new type of velocity adjustable tuned mass damper (TMD) consisting of impulse generators and clutches is presented. The force impulse is generated by a joining operation of electromagnets and springs and MR dampers are used as clutches. Rules for velocity adjustment are established according to the working mechanism of TMD. The analysis program is developed on a VB platform. Seismic response of SDOF structures with both passive TMD and velocity adjustable TMD are analyzed. The results show that (1) the control effectiveness of passive TMDs is usually unstable; (2) the control effectiveness of the proposed semi-active TMDs is much better than passive TMDs under typical seismic ground motions; and (3) unlike the passive TMD system, the proposed velocity adjustable TMDs exhibit good control effectiveness even when the primary structure performance becomes inelastic during severe earthquakes.  相似文献   

20.
The self‐centering rocking steel frame is a seismic force resisting system in which a gap is allowed to form between a concentrically braced steel frame and the foundation. Downward vertical force applied to the rocking frame by post‐tensioning acts to close the uplifting gap and thus produces a restoring force. A key feature of the system is replaceable energy‐dissipating devices that act as structural fuses by producing high initial system stiffness and then yielding to dissipate energy from the input loading and protect the remaining portions of the structure from damage. In this research, a series of large‐scale hybrid simulation tests were performed to investigate the seismic performance of the self‐centering rocking steel frame and in particular, the ability of the controlled rocking system to self‐center the entire building. The hybrid simulation experiments were conducted in conjunction with computational modules, one that simulated the destabilizing P‐Δ effect and another module that simulated the hysteretic behavior of the rest of the building including simple composite steel/concrete shear beam‐to‐column connections and partition walls. These tests complement a series of quasi‐static cyclic and dynamic shake table tests that have been conducted on this system in prior work. The hybrid simulation tests validated the expected seismic performance as the system was subjected to ground motions in excess of the maximum considered earthquake, produced virtually no residual drift after every ground motion, did not produce inelasticity in the steel frame or post‐tensioning, and concentrated the inelasticity in fuse elements that were easily replaced. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏