首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
Semi‐active dampers offer significant capability to reduce dynamic wind and seismic structural response. A novel resetable device with independent valve control laws that enables semi‐active re‐shaping of the overall structural hysteretic behaviour has been recently developed, and a one‐fifth scale prototype experimentally validated. This research statistically analyses three methods of re‐shaping structural hysteretic dynamics in a performance‐based seismic design context. Displacement, structural force, and total base‐shear response reduction factor spectra are obtained for suites of ground motions from the SAC project. Results indicate that the reduction factors are suite invariant. Resisting all motion adds damping in all four quadrants and showed 40–60% reductions in the structural force and displacement at the cost of a 20–60% increase in total base‐shear. Resisting only motion away from equilibrium adds damping in quadrants 1 and 3, and provides reductions of 20–40%, with a 20–50% increase in total base‐shear. However, only resisting motion towards equilibrium adds damping in quadrants 2 and 4 only, for which the structural responses and total base‐shear are reduced 20–40%. The spectral analysis results are used to create empirical reduction factor equations suitable for use in performance based design methods, creating an avenue for designing these devices into structural applications. Overall, the reductions in both response and base‐shear indicate the potential appeal of this semi‐active hysteresis sculpting approach for seismic retrofit applications—largely due to the reduction of the structural force and overturning demands on the foundation system. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

2.
An investigation on the validity of the conventional design approach known as constant displacement ductility is carried out. The hysteretic behaviour described by the Modified Takeda model is taken to represent the characteristics of reinforced concrete structural systems. The results presented in the form of seismic damage spectra indicate that the conventional design approach may not be valid because cumulative damage is excessively high. The inelastic design spectra based on the constant‐damage concept are proposed in terms of simplified expressions. The expressions are derived from constant‐damage design spectra computed by non‐linear response analysis for SDOF systems subjected to ground motions recorded on rock sites, alluvium deposits, and soft‐soil sites. The proposed expressions, which are dependent on the local soil conditions, are functions of target seismic damage, displacement ductility ratio and period of vibration. The seismic damage of structures that have been designed based on this new design approach is also checked by a design‐and‐evaluation approach. The results are found to be satisfactory. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

3.
The next generation of seismic design codes, especially those adopting the framework of performance‐based design, will include the option of design based on displacements rather than forces. For direct displacement‐based design using the substitute structure approach, the spectral ordinates of displacement need to be specified for a wide range of response periods and for several levels of damping. The code displacement spectra for damping values higher than the nominal value of 5% of critical will generally be obtained, as is the case in Eurocode 8 and other design codes, by applying scaling factors to the 5% damped ordinates. These scaling factors are defined as functions of the damping ratio and, in some cases, the response period, but are independent of the nature of the expected ground shaking. Using both predictive equations for spectral ordinates at several damping levels and stochastic simulations, it is shown that the scaling factors for different damping levels vary with magnitude and distance, reflecting a dependence of the scaling on the duration of shaking that increases with the damping ratio. The options for incorporating the influence of this factor into design code specifications of displacement response spectra are discussed. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

4.
Damping modification factors (DMF) are used in modern seismic codes to adjust elastic response spectral values corresponding to 5% of viscous damping to other higher or lower damping levels. This paper presents a simple and effective procedure to estimate DMF for single‐degree‐of‐freedom systems. Empirical expressions are proposed for displacement, velocity and acceleration response spectra, where four types of soil conditions, from hard rock to soft soil are considered. This study also examines, for the first time, the influence of artificial earthquakes on DMF. Furthermore, natural near‐fault and far‐fault seismic ground motions are considered where it is testified that the fault distance has no impact on DMF. Finally, it confirms that, in contrast to the considerations of many seismic codes, DMF are strongly dependent on the period of structural vibration while there are significant problems of using the same modification factor to estimate maximum displacement, velocity and seismic forces. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
In order to investigate the response of structures to near‐fault seismic excitations, the ground motion input should be properly characterized and parameterized in terms of simple, yet accurate and reliable, mathematical models whose input parameters have a clear physical interpretation and scale, to the extent possible, with earthquake magnitude. Such a mathematical model for the representation of the coherent (long‐period) ground motion components has been proposed by the authors in a previous study and is being exploited in this article for the investigation of the elastic and inelastic response of the single‐degree‐of‐freedom (SDOF) system to near‐fault seismic excitations. A parametric analysis of the dynamic response of the SDOF system as a function of the input parameters of the mathematical model is performed to gain insight regarding the near‐fault ground motion characteristics that significantly affect the elastic and inelastic structural performance. A parameter of the mathematical representation of near‐fault motions, referred to as ‘pulse duration’ (TP), emerges as a key parameter of the problem under investigation. Specifically, TP is employed to normalize the elastic and inelastic response spectra of actual near‐fault strong ground motion records. Such normalization makes feasible the specification of design spectra and reduction factors appropriate for near‐fault ground motions. The ‘pulse duration’ (TP) is related to an important parameter of the rupture process referred to as ‘rise time’ (τ) which is controlled by the dimension of the sub‐events that compose the mainshock. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

6.
Buildings are continually subject to dynamic loads, such as wind load, seismic ground motion, and even the load from internal utility machines. The recent trend of constructing more flexible high‐rise buildings underscores the importance of including viscoelastic dampers in building designs. Viscoelastic dampers are used to control the dynamic response of a building. If the seismic design is based only on the linear response spectrum, considerable error may occur when calculating the seismic response of a building; rubber viscoelastic dampers show non‐linear hysteretic damping that is quite different from viscous damping. This study generated a non‐linear response spectrum using a non‐linear oscillator model to simulate a building with viscoelastic dampers installed. The parameters used in the non‐linear damper model were obtained experimentally from dynamic loading tests. The results show that viscoelastic dampers effectively reduce the seismic displacement response of a structure, but transmit more seismic force to the structure, which essentially increases its seismic acceleration response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

7.
Structural design code provisions worldwide prescribe relatively small seismic force reduction factors for seismically base‐isolated structures, making their response to design‐level earthquake excitation essentially elastic. This paper uses the method of dimensional analysis to prove that; in most cases, this is not a conservative design approach but a necessity that emerges from the dynamics of base‐isolated structures. It is shown that allowing typical base‐isolated structures to yield results in large displacement ductility demands for the structure. This phenomenon is caused by the change in the nature of the ground motion excitation as it is transmitted to the structure through the seismic base isolation system as well as by the change in the distribution of displacements between the structure and the isolation bearings caused by yielding of the isolated structure. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
This study uses a semi‐active viscous damper with three different control laws to reshape the structural hysteresis loop and mitigate structural response, referred to as 1–4, 1–3 and 2–4 devices, respectively. The 1–4 control law provides damping in all four quadrants of the force‐displacement graph (it behaves like a standard viscous damper), the 1–3 control law provides resisting forces only in the first and third quadrants, and the 2–4 control law provides damping in the second and fourth quadrants. This paper first outlines the linear single degree of freedom structural performance when the three types of semi‐active viscous dampers are applied. The results show that simultaneous reduction in both displacement and base‐shear demand is only available with the semi‐active 2–4 device. To enable guidelines for adding a 2–4 device into the design procedure, damping reduction factors (RFξs) are developed, as they play an important role and provide a means of linking devices to design procedures. Three methods are presented to obtain RFξ and equivalent viscous damping of a structure with a 2–4 semi‐active viscous damper. In the first method, the relationship between RFξ and the damping of a semi‐active structure can be obtained by calculating the area under the force‐deformation diagram. The second and third method modified the Eurocode8 formula of RFξ and smoothed results from analysis, respectively. Finally, a simple method is proposed to incorporate the design or retrofit of structures with simple, robust and reliable 2–4 semi‐active viscous dampers using standard design approaches. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
The purpose of this paper is to investigate the effects of liquefaction on modal parameters (frequency and damping) of pile‐supported structures. Four physical models, consisting of two single piles and two 2 × 2 pile groups, were tested in a shaking table where the soil surrounding the pile liquefied because of seismic shaking. The experimental results showed that the natural frequency of pile‐supported structures may decrease considerably owing to the loss of lateral support offered by the soil to the pile. On the other hand, the damping ratio of structure may increase to values in excess of 20%. These findings have important design consequences: (a) for low‐period structures, substantial reduction of spectral acceleration is expected; (b) during and after liquefaction, the response of the system may be dictated by the interactions of multiple loadings, that is, horizontal, axial and overturning moment, which were negligible prior to liquefaction; and (c) with the onset of liquefaction due to increased flexibility of pile‐supported structure, larger spectral displacement may be expected, which in turn may enhance P‐delta effects and consequently amplification of overturning moment. Practical implications for pile design are discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
The results of experimental tests carried out on reinforced concrete (RC) full‐scale 2‐storey 2‐bays framed buildings are presented. The unretrofitted frame was designed for gravity loads only and without seismic details; such frame was assumed as a benchmark system in this study. A similar RC frame was retrofitted with buckling‐restrained braces (BRBs). The earthquake structural performance of both prototypes was investigated experimentally using displacement‐controlled pushover static and cyclic lateral loads. Modal response properties of the prototypes were also determined before and after the occurrence of structural damage. The results of the dynamic response analyses were utilized to assess the existing design rules for the estimation of the elastic and inelastic period of vibrations. Similarly, the values of equivalent damping were compared with code‐base relationships. It was found that the existing formulations need major revisions when they are used to predict the structural response of as‐built RC framed buildings. The equivalent damping ratio ξeq was augmented by more than 50% when the BRBs was employed as bracing system. For the retrofitted frame, the overstrength Ω and the ductility µ are 1.6 and 4.1, respectively; the estimated R‐factor is 6.5. The use of BRBs is thus a viable means to enhance efficiently the lateral stiffness and strength, the energy absorption and dissipation capacity of the existing RC substandard frame buildings. The foundation systems and the existing members of the superstructure are generally not overstressed as the seismic demand imposed on them can be controlled by the axial stiffness and the yielding force of the BRBs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
Soil effects on peak ground acceleration, velocity and elastic response spectra (5% damping) are expressed by simple approximate relations in terms of five key parameters: (a) the fundamental vibration period of the non‐linear soil, TS, (b) the period of a bedrock site of equal thickness, Tb, (c) the predominant excitation period, Te, (d) the peak seismic acceleration at outcropping bedrock, a, and (e) the number of significant excitation cycles, n. Furthermore, another relation is proposed for the estimation of TS in terms of the soil thickness H, the average shear wave velocity of the soil V?S,o and a. The aforementioned parameters were first identified through a simplified analytical simulation of the site excitation. The multivariable approximate relations were then formulated via a statistical analysis of relevant data from more than 700 one‐dimensional equivalent‐linear seismic ground response analyses, for actual seismic excitations and natural soil conditions. Use of these relations to back‐calculate the numerical results in the database gives an estimate of their error margin, which is found to be relatively small and unbiased. The proposed relations are also independently verified through a detailed comparison with strong motion recordings from seven well‐documented case studies: (a) two sites in the San Fernando valley during the Northridge earthquake, and (b) five different seismic events recorded at the SMART‐1 accelerometer array in Taiwan. It is deduced that the accuracy of the relations is comparable to that of the equivalent‐linear method. Hence, they can be readily used as a quick alternative for routine applications, as well as for spreadsheet computations (e.g. GIS‐aided seismic microzonation studies) where numerical methods are cumbersome to implement. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

12.
Within the last decades, simplified methods alternative to dynamic nonlinear analysis have been developed to estimate the seismic performance of structures toward a performance‐oriented design. Considering drift as the main parameter correlated with structural damage, its estimation is of main importance to assess the structural performance. While traditional force‐based design deals with calibrated force reduction factors based on the expected structural ductility, other methods are based on the definition of a viscous damping factor defined as a function of the expected energy dissipated by the structure. An example is the capacity spectrum method. This method can be applied even without any a priori calibration or designer arbitrariness. This allows considering several peculiarities of the seismic behavior of precast structures, which may be influenced by nontraditional hysteresis of connections and members, interaction with the cladding panels, Pδ effects, etc. The paper aims at verifying the soundness and accuracy of this method through the comparison of its predictions against the results of cyclic and pseudodynamic tests on precast structures, including single‐ and multistory buildings either stiff or flexible, obtained on full‐scale building prototypes tested within the framework of recent research projects (namely, “Precast Structures EC8,” “Safecast,” and “Safecladding”). Two simple methodologies of determination of the equivalent viscous damping from a force‐displacement cycle, based on the dissipated energy in relation to 2 different estimates of the elastic strain energy, are addressed and compared. Comments on the possible use of this procedure for the estimation of the seismic performance of precast structures are provided.  相似文献   

13.
A procedure for treating the P– Δ effect in the direct displacement‐based seismic design of regular steel moment resisting frames with ideal elastoplastic material behaviour is proposed. A simple formula for the yield displacement amplification factor as a function of ductility and the stability coefficient is derived on the basis of the seismic response of an inelastic single degree‐of‐freedom system taking into account the P– Δ effect. Extensive parametric seismic inelastic analyses of plane moment resisting steel frames result in a simple formula for the dynamic stability coefficient as a function of the number of stories of a frame and the column to beam stiffness ratio. Thus, the P– Δ effect can be easily taken into account in a direct displacement‐based seismic design through the stability coefficient and the yield displacement amplification factor. A simple design example serves to illustrate the application of the proposed method and demonstrate its merits. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

14.
This paper proposes energy input spectra applicable to seismic design of structures located in low‐to‐moderate‐seismicity regions. These spectra represent the load effect, in terms of input energy, of the most severe earthquake that the construction might encounter during its lifetime. The spectra have been derived through dynamic response analyses of over 100 ground motion records obtained from 48 earthquakes that have occurred in Spain. An empirical equation for estimating the energy input contributable to damage from the total input energy is also suggested. This equation takes into account both the damping and the degree of plastification of the structure. Finally, the proposed design energy input spectra are compared with the provisions of the current Spanish Seismic Code and with the response spectra of recent earthquakes that have occurred in Turkey and Taiwan. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

15.
双向地震动作用的拟等延性系数谱   总被引:1,自引:0,他引:1  
首先建立了以强度折减系数表述的恢复力特性满足二维屈服面模型的理想弹塑性单质点系统(它在2个相互垂直的主轴方向上分别具有水平平动自由度)在双向地震动作用下的归一化运动方程。然后引入单向地震动作用下等延性系数的强度折减系数谱,给出了双向地震动作用的拟等延性系数谱(定义为系统分别承受双向和单向地震动作用,在同一主轴方向上的最大位移反应之比)最后通过硬土场地10组双向地震动记录拟等延性系数谱的统计平均结果,分析了结构周期、位移延性系数和阻尼等因素对谱值及结构双向地震反应的影响。结果表明,双向地震动作用与单向地震动作用相比主要增加结构较长周期方向的最大位移反应。若在基于位移的抗震设计中降低结构较短周期方向的设计位移延性系数,可在一定程度上降低双向地震动的不利影响。因定义的谱为比值形式,阻尼对其影响不大。  相似文献   

16.
Passive high force‐to‐volume (HF2V) dampers offer significant displacement reduction and energy dissipation, but cannot customise overall response. Semi‐active resettable devices offer adaptive, custom hysteresis loops that reduce displacement and base shear, but have limited dissipation. This paper presents a new, combined concept to maximise displacement reduction without increasing base shear – a net‐zero base‐shear concept. HF2V devices, up to a maximum of 10% structural weight, are combined with fixed stiffness resettable devices. Spectral analyses are run for the three SAC ground motion suites that iteratively size the HF2V device at each structural period to achieve maximum displacement reductions without increasing median base shear. HF2V velocity dependence and the need to scale HF2V capacity to spectral velocity are examined in terms of their impact on the results of these analyses. The net‐zero approach reduces base shear by up to 50% and displacements by 30–70% over all ground motions, exceeding reductions obtained by either device separately by 30–50% (relative). The net‐zero condition is not reached within the device limits defined, except at relatively long periods (>3.5 s) because of a virtuous circle of reduced displacement from the resettable and HF2V devices outweighing the increased base shear from the HF2V devices alone. These results are independent of HF2V device scaling, design and velocity dependence. The overall net‐zero concept offers a significant advantage in a combination that cannot be achieved by passive or semi‐active solutions alone. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
In Italy, as in other high seismic risk countries, many bridges, nowadays deemed ‘strategic’ for civil protection interventions after an earthquake, were built without antiseismic criteria, and therefore their seismic assessment is mandatory. Accordingly, the development of a seismic assessment procedure that gives reliable results and, at the same time, is sufficiently simple to be applied on a large population of bridges in a short time is very useful. In this paper, a displacement‐based procedure for the assessment of multi‐span RC bridges, satisfying these requirements and called direct displacement‐based assessment (DDBA), is proposed. Based on the direct displacement‐based design previously developed by Priestley et al., DDBA idealizes the multi DOF bridge structure as an equivalent SDOF system and hence defines a safety factor in terms of displacement. DDBA was applied to hypothetical bridge configurations. The same structures were analyzed also using standard force‐based approach. The reliability of the two methods was checked performing IDA with response spectrum compatible accelerograms. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
The seismic design of multi‐story buildings asymmetric in plan yet regular in elevation and stiffened with ductile RC structural walls is addressed. A realistic modeling of the non‐linear ductile behavior of the RC walls is considered in combination with the characteristics of the dynamic torsional response of asymmetric buildings. Design criteria such as the determination of the system ductility, taking into account the location and ductility demand of the RC walls, the story‐drift demand at the softer (most displaced) edge of the building under the design earthquake, the allowable ductility (ultimate limit state) and the allowable story‐drift (performance goals) are discussed. The definition of an eccentricity of the earthquake‐equivalent lateral force is proposed and used to determine the effective displacement profile of the building yet not the strength distribution under the design earthquake. Furthermore, an appropriate procedure is proposed to calculate the fundamental frequency and the earthquake‐equivalent lateral force. A new deformation‐based seismic design method taking into account the characteristics of the dynamic torsional response, the ductility of the RC walls, the system ductility and the story‐drift at the softer (most displaced) edge of the building is presented and illustrated with an example of seismic design of a multi‐story asymmetric RC wall building. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

20.
Simplified approaches for examining structural system response under sequential earthquake and tsunami loading are helpful for understanding response trends. To aid understanding, nonlinear (constant‐ductility) response spectra are developed for elastoplastic single degree of freedom systems subjected to seismic loads followed by hydrodynamic tsunami loads. The forcing function is composed of long‐duration earthquake motion concatenated with a range of tsunami hydrodynamic forces that are proportional to the pseudo‐spectral acceleration produced by the earthquake motion. The constant‐ductility spectra are thus constructed for scenarios where the loading imposed by one hazard is not dominant over the other. The spectra and basic intensity measures indicate that the amplification of response for sequential earthquake and tsunami loading over the earthquake only case is most significant for systems with long natural periods and high‐ductility capacity under seismic loading. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   