首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper first presents the force–deformation relationship of a post‐tensioned (PT) steel beam‐to‐column connection constructed with bolted web friction devices (FDs). This paper then describes the test program conducted in the National Center for Research on Earthquake Engineering, Taiwan, on four bolted FDs and four full‐scale PT beam‐to‐column moment connection subassemblies using the FDs. Tests confirm that (1) the hysteretic behavior of four bolted FDs is very stable, (2) the friction coefficient between the steel plate and the brass shim is about 0.34, (3) the proposed force–deformation relationships reasonably predict the experimental responses of the PT connections under cyclically increasing deformations up to a beam peak rotation of 0.05 rad, and (4) the decompression moments do not degrade as beam cyclic deformations increase. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

2.
The work presented is aimed at the investigation of the influence of beam‐to‐column connections on the seismic response of MR‐Frames, with and without ‘set‐backs’, designed according to the Theory of Plastic Mechanism Control. The investigated connection typologies are four partial strength connections whose structural details have been designed to obtain the same flexural resistance. The first three joints are designed by means of hierarchy criteria based on the component approach and are characterized by different location of the weakest joint component, leading to different values of joint rotational stiffness and plastic rotation supply and affecting the shape of the hysteresis loops governing the dissipative capacity. The last typology is a beam‐to‐column connection equipped with friction pads devoted to the dissipation of the earthquake input energy, thus preventing the connection damage. An appropriate modelling is needed to accurately represent both strength and deformation characteristics, especially with reference to partial‐strength connections where the dissipation of the earthquake input energy occurs. To this aim, beam‐to‐column joints are modelled by means of rotational inelastic springs located at the ends of the beams whose moment‐rotation curve is characterized by a cyclic behaviour which accounts for stiffness and strength degradation and pinching phenomena. The parameters characterizing the cyclic hysteretic behaviour have been calibrated on the base of experimental results aiming to the best fitting. Successively, the prediction of the structural response of MR‐Frames, both regular frames and frames with set‐backs, equipped with such connections has been carried out by means of both push‐over and Incremental Dynamic Analyses. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Six cyclic tests were conducted on three full‐scale subassemblies to investigate the behavior of interior beam‐to‐column post‐tensioned (PT) connections. Strands were placed along each side of the steel beam web, passing through the steel column to provide precompression between the beams and a column. Top and bottom energy‐dissipating (ED) bars, passing through the column and welded to the beam, were used to increase the moment capacity and ED capacity of the connection. One of the subassemblies also had a composite concrete slab with discontinuity at the column centerline to eliminate restraint from the metal deck, reinforcement, and welded wire mesh. The objectives of this paper were to investigate the following: the durability of the connection by loading each specimen twice, the ED capacity of the ED bar, and the effects that the type of ED bar and type of composite slab have on the self‐centering behavior of the connection. The experimental results showed that: (1) the connection could sustain severe inelastic cyclic loading at least twice without strength degradation, (2) the ED capacity of the bar was much larger than that dissipated by a single AISC loading protocol, and (3) a specimen with a discontinuous composite slab, which opened freely at the centerline of the column, ensured the same self‐centering hysteretic behavior as the bare steel specimen. However, the decompression moment of the PT connection decreased significantly at each interstory drift, resulting in an early opening of a gap at the beam–column interface. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
Reinforced concrete wide beam–column connections have been used in low‐to‐moderate seismicity regions despite little information being available on their seismic performance. This research was conducted to clarify experimentally the hysteretic behaviour and ultimate energy dissipation capacity (UEDC) of this type of existing connection under lateral dynamic earthquake loadings. For this purpose, ? scale models were constructed and tested on a shaking table until they collapsed. The exterior connection behaved as a strong column–weak beam mechanism, and the interior connection as a weak column–strong beam mechanism. The averaged UEDC of the connections in each domain of loading, normalized with respect to the product of the yield strength and yield displacement, were about 6 and 5 for the exterior and interior connections, respectively. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
The seismic response of single‐degree‐of‐freedom (SDOF) systems incorporating flag‐shaped hysteretic structural behaviour, with self‐centring capability, is investigated numerically. For a SDOF system with a given initial period and strength level, the flag‐shaped hysteretic behaviour is fully defined by a post‐yielding stiffness parameter and an energy‐dissipation parameter. A comprehensive parametric study was conducted to determine the influence of these parameters on SDOF structural response, in terms of displacement ductility, absolute acceleration and absorbed energy. This parametric study was conducted using an ensemble of 20 historical earthquake records corresponding to ordinary ground motions having a probability of exceedence of 10% in 50 years, in California. The responses of the flag‐shaped hysteretic SDOF systems are compared against the responses of similar bilinear elasto‐plastic hysteretic SDOF systems. In this study the elasto‐plastic hysteretic SDOF systems are assigned parameters representative of steel moment resisting frames (MRFs) with post‐Northridge welded beam‐to‐column connections. In turn, the flag‐shaped hysteretic SDOF systems are representative of steel MRFs with newly proposed post‐tensioned energy‐dissipating connections. Building structures with initial periods ranging from 0.1 to 2.0s and having various strength levels are considered. It is shown that a flag‐shaped hysteretic SDOF system of equal or lesser strength can always be found to match or better the response of an elasto‐plastic hysteretic SDOF system in terms of displacement ductility and without incurring any residual drift from the seismic event. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
A rate‐dependent modeling technique is developed for moment resisting steel connections that utilize non‐linear viscous dampers. First, a model of the Maxwell‐type is developed that considers the non‐linear viscous damper and connection flexibility for translational motion. This model is compared with experimental results at several input motion frequencies to validate the results. The model is then extended to represent an exterior steel beam‐to‐column connection using damage‐avoidance design and non‐linear viscous dampers. By including terms to represent structural member and connection flexibility, using appropriate geometric transformations the model can be formulated to give the overall lateral load‐drift structural performance. Validation analysis shows good agreement between experimental observations and the model predictions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A gusset plate is subjected to forces induced from a buckling‐restrained brace (BRB) and frame action. In this study, a performance‐based design method of the gusset connections incorporating a BRB and frame actions is investigated. The force demands resulting from the BRB axial force are computed from the generalized uniform force method. The force demands induced from the frame action effects primarily result from beam shear. A conservative method, which considers the beam axial force effect and the thereafter reduced beam flexural capacity possibly developed at the gusset tips, is adopted in estimating the maximum beam shear. An improved equivalent strut model is used to represent the gusset plate subjected to the frame action effect. The total force demands of the gusset connection are combined from the BRB force and the frame actions. For design purposes, the stress distributions on the gusset interfaces are linearized. The maximum von Mises stress combining the normal and shear stresses is considered as the demand for the gusset plate design. In order to verify the effectiveness of the proposed design method, experiments on a two‐story full‐scale buckling‐restrained braced frame (BRBF) were performed. The chevron and single diagonal brace configurations were arranged in the second and the first stories, respectively. Two different corner gusset connection configurations including one single corner gusset and one coupled corner gusset connection, where two braces in adjacent stories joined at the same beam‐to‐column joint, were tested. The BRBF specimen was subjected to cyclically increasing lateral displacements with a maximum frame drift of 0.04 rad. The maximum story drifts reached 0.035 and 0.061 rad. in the first and the second stories, respectively. At the end of the tests, no fractures were observed on any of the gusset interfaces. Along the gusset interfaces, the normal and shear stress distributions computed from the proposed design procedures and the FEM analysis correlated well with the experimental results. This paper concludes with the procedure and recommendations for the performance‐based design of gusset connections. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
The seismic capacity of beam‐to‐column connections in steel high‐rise frames is a matter of concern, particularly when they are subjected to long‐period ground motions. A previous full‐scale shaking table test conducted at the E‐Defense National Research Institute for Earth Science and Disaster Prevention in Japan disclosed cracks and fractures in such beam‐to‐column connections. This paper examines the effects of three types of beam‐to‐column connection retrofit: supplemental welds, wing plates, and a haunch. Quasi‐static member tests and a series of shaking table tests applied to a full‐scale specimen are conducted to quantify the respective performances of the retrofit schemes. The performance of a total of 28 connections tested by the member and shaking table tests is evaluated together with that of an additional 12 unretrofitted connections tested in the previous test. When the supplemental welds are applied only to the shear tab to the web, the connection fractures at the same instant as the connection without retrofit. The corresponding cumulative plastic rotation is not improved. When the supplement welds are further applied to the web‐to‐column connection, strain concentration at the bottom flange, primarily promoted by the presence of the RC floor slab, is significantly reduced, and the cumulative plastic rotation capacity is increased to eight times that of the connection without retrofit. For the wing plate connection and haunch connection, the critical section is moved from the beam end to the beam cross‐section corresponding to the tip of the wing plates or haunch, resulting in an improvement of ductility by eight times that of the unretrofitted connection. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
The self‐centering prestressed concrete (SCPC) moment resisting frame (MRF) with web friction devices (WFDs) is a new type of structure that integrates advantages of post‐tensioned precast concrete MRFs and self‐centering steel MRFs. In this paper, the configuration of the connection and design guidelines are presented. To further reduce damage to the connection under cyclic loading and facilitate implementation in practice, several significant improvements are proposed and experimentally validated in this study, including the following: (i) the welded connection is replaced by the bolted connection; (ii) aluminum plates are used for friction instead of brass plates to reduce the material costs without decreasing the energy dissipation capacity; and (iii) post‐tensioned tendons at the corners of the beam are replaced by a bundle of tendons at the beam centroid in order to facilitate the field assembly. The resulting improvements of seismic performances are experimentally demonstrated by 10 cyclic tests of two full‐scale SCPC beam–column connections. Numerical simulation of the proposed connection is conducted using the Open System for Earthquake Engineering Simulation (OpenSees) to replicate the experimental results. Seismic behaviors are taken into account, such as the gap opening/closing at the beam–column interface, the self‐centering capacity, and the friction energy dissipation. Good agreement is observed between the numerical simulation and the test results. The proposed SCPC connection with bolted WFDs is demonstrated to have good performance when subjected to cyclic loading. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
This paper presents the results of a multi‐level pseudo‐dynamic seismic test program that was performed to assess the performance of a full‐scale three‐bay, two‐storey steel–concrete composite moment‐resisting frame built with partially encased composite columns and partial‐strength beam‐to‐column joints. The system was designed to develop a ductile response in the joint components of beam‐to‐column joints including flexural yielding of beam end plates and shear yielding of the column web panel zone. The ground motion producing the damageability limit state interstorey drift caused minor damage while the ultimate limit state ground motion level entailed column web panel yielding, connection yielding and plastic hinging at the column base connections. The earthquake level chosen to approach the collapse limit state induced more damage and was accompanied by further column web panel yielding, connection yielding and inelastic phenomena at column base connections without local buckling. During the final quasi‐static cyclic test with stepwise increasing displacement–amplitudes up to an interstorey drift angle of 4.6%, the behaviour was ductile although cracking of beam‐to‐end‐plate welds was observed. Correlations with numerical simulations taking into account the inelastic cyclic response of beam‐to‐column and column base joints are also presented in the paper together. Inelastic static pushover and time history analysis procedures are used to estimate the structural behaviour and overstrength factors of the structural system under study. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

11.
A series of E‐Defense shaking table tests are conducted on a large‐scale test specimen that represents a high‐rise steel building. Two types of connections featuring the connection details commonly used in 1970s, in the early days of high‐rise construction in Japan, are adopted: the field‐welded connection consisting of welded unreinforced flanges and a bolted web type, and the shop‐welded connection in which the flanges and web are all‐welded to the column flange in the shop. To examine the seismic capacity of a total of 24 beam‐to‐column connections of the specimen, particularly when it is subjected to long‐period ground motion characterized not so much by large amplitude as by very many cycles of repeated loading, the test specimen is shaken repeatedly until the connections fractured. The test results indicate that a few of the field‐welded connections fractured from the bottom flange weld boundary in a relatively small cumulative rotation primarily due to the difficulties in ensuring the welding and inspection performance in the actual field welding. The shop‐welded connections are able to sustain many cycles of plastic rotation, with an averaged cumulative plastic rotation of 0.86 rad. Two shop‐welded connections exhibit ductile fractures but only after experiencing many cycles. The presence of RC floor slabs promotes the strain concentration at the toe of the weld access hole in the bottom flange by at least twice compared with the case without the slab, which had resulted in a decrease in the cumulative plastic rotation by about 50%. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
In precast technology, the effective design and construction are related to the behaviour of the connections between the structural members in order to cater for all service, environmental and earthquake load conditions. Therefore, the design and detailing of the connections should be undertaken consistently and with awareness of the desired structural response. In the research presented herein, an analytical expression is proposed for the prediction of the resistance of precast pinned connections under shear monotonic and cyclic loading. The proposed formula addresses the case where the failure of the connection occurs with simultaneous flexural failure of the dowel and compression failure of the concrete around the dowel, expected to occur either when (i) adequate concrete cover of the dowels is provided (d > 6 D) or (ii) adequate confining reinforcement (as defined in the article) is foreseen around the dowels in the case of small concrete covers (d < 6 D). The expression is calibrated against available experimental data and numerical results derived from a nonlinear numerical investigation. Emphasis is given to identifying the effect of several parameters on the horizontal shear resistance of the connection such as: the number and diameter of the dowels; the strength of materials (concrete, grout, steel); the concrete cover of the dowels; the thickness of the elastomeric pad; the type of shear loading (monotonic or cyclic); the pre‐existing axial stress in the dowels; and the rotation of the joint. In addition, recommendations for the design of precast pinned beam‐to‐column connections are given, especially when the connections are utilised in earthquake resistant structures. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

13.
Ductile‐jointed connections, which generally require some form of supplementary energy dissipation to alleviate displacement response, typically employ mild steel energy dissipation devices. These devices run the risk of low‐cycle fatigue, are effective only for peak cycles that exceed prior displacements, are prone to buckling, and may require replacement following an earthquake. This study presents an experimental investigation employing an alternative to mild steel: a high force‐to‐volume (HF2V) class of damper‐based energy dissipation devices. Tests are performed on a near full‐scale beam–column joint subassembly utilizing externally mounted compact HF2V devices. Two configurations are considered: an exterior joint with two seismic beams and one gravity beam framing into a central column, and a corner joint with only one seismic beam and one gravity beam framing into a column. Quasi‐static tests are performed to column drifts up to 4%. The experiments validate the efficacy of the HF2V device concept, demonstrating good hysteretic energy dissipation, and minimal residual device force, allowing ready re‐centring of the joint. The devices dissipate energy consistently on every cycle without the deterioration observed in the yielding steel bar type of devices. The effectiveness of the HF2V devices on structural hysteretic behavior is noted to be sensitive to the relative stiffness of the anchoring elements, indicating that better efficiency would be obtained in an embedded design. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
This paper investigates the effect of the composite action on the seismic performance of steel special moment frames (SMFs) through collapse. A rational approach is first proposed to model the hysteretic behavior of fully restrained composite beam‐to‐column connections, with reduced beam sections. Using the proposed modeling recommendations, a system‐level analytical study is performed on archetype steel buildings that utilize perimeter steel SMFs, with different heights, designed in the West‐Coast of the USA. It is shown that in average, the composite action may enhance the seismic performance of steel SMFs. However, bottom story collapse mechanisms may be triggered leading to rapid deterioration of the global strength of steel SMFs. Because of composite action, excessive panel zone shear distortion is also observed in interior joints of steel SMFs designed with strong‐column/weak‐beam ratios larger than 1.0. It is demonstrated that when steel SMFs are designed with strong‐column/weak‐beam ratios larger than 1.5, (i) bottom story collapse mechanisms are typically avoided; (ii) a tolerable probability of collapse is achieved in a return period of 50 years; and (iii) controlled panel zone yielding is achieved while reducing the required number of welded doubler plates in interior beam‐to‐column joints. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
New steel moment‐resisting connections that incorporate post‐tensioning elements to provide a self‐centering capacity and devices to dissipate seismic input energy have recently been proposed and experimentally validated. Experimental studies have confirmed that these connections are capable of undergoing large lateral deformations with negligible residual drifts. To facilitate their implementation, accurate modeling of the behavior of systems incorporating post‐tensioned connections must be readily available to designers and researchers. A number of simplified models have been suggested in the literature by researchers trying to capture experimental results at the beam–column connections and thereby to predict the global response of structures incorporating such connections. To provide a clear set of guidelines for the modeling of post‐tensioned steel frames, for practicing engineers as well as researchers, in this paper three types of numerical models of increasing complexity are presented: (i) a sectional analysis procedure, (ii) a lumped plasticity spring frame leveled approach and (iii) a non‐linear solid finite element analysis to predict the response at ultimate deformation levels. The analytical results obtained from the numerical models predict well the structural behavior of these connections when compared with available experimental data. Even at the ultimate deformation level, analytical results are in good agreement with test results. Furthermore, detailing requirements are proposed to assure that flexural hinges form in the beams in order to improve the cyclic response of steel self‐centering connections when drifts exceeding the design drifts are imposed to the system. Experimental and analytical studies demonstrate that steel post‐tensioned self‐centering connections incorporating the proposed detailing in the beams develop an increased deformation capacity and thereby exhibit a ductile response while avoiding a sudden loss of their strength and stiffness. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
This paper investigates the seismic behaviour of moment‐resisting timber frames with beam‐column joints fastened with expanded tubes and reinforced with densified veneer wood. Laboratory experiments are carried out on single joints to investigate the cyclic behaviour and, more specifically, the impairment of strength, the ductility ratio and the equivalent viscous damping ratio. A phenomenological numerical model is proposed, where the beams and columns are schematized using linear‐elastic beam elements, and the joints with non‐linear hysteretic spring calibrated on the results of the experimental tests. The model is used to analyse some representative moment‐transmitting structures characterised by different number of bays and storeys. After an estimation of the lateral load‐carrying capacity using a pushover analysis, the numerical model is used to estimate the behaviour factor. An incremental dynamic analysis is performed using a set of accelerograms spectrum consistent with a chosen design spectrum. The analyses lead to an estimation of the behaviour factor of 3 and 6 for a portal frame and a five‐storey, three‐bay frame, respectively, which confirms the highly dissipative behaviour of this kind of moment connection. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

17.
A welded end‐slot buckling‐restrained brace (WES‐BRB) has been developed at the Taiwan National Center for Research on Earthquake Engineering (NCREE). A steel frame equipped with a WES‐BRB can offer a cost‐effective solution to meet interstory drift and earthquake‐resistant design requirements for seismic steel buildings. According to the WES‐BRB and connection design procedure proposed by NCREE, there are seven key elements of a buckling‐restrained braced frame (BRBF) design that require design checking. In order to assist an engineer with the design of the WES‐BRB members and connections, an innovative cloud service named Brace on Demand has been constructed at NCREE. In this study, using 581 BRBF design examples, the effectiveness of the proposed design procedures to meet all design checks is demonstrated. It is found that the most critical limit states for an initial design are joint region buckling, gusset plate buckling, and gusset‐to‐beam and gusset‐to‐column interface strength. Accordingly, the causes of improper designs and associated strategies for improving the initial designs are discussed in this paper. Recommendations on initial selections including the BRB joint size and gusset plate thickness are given. The paper provides the detailed road map for engineers to develop the spreadsheet for BRB and connection designs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Recent earthquakes in Italy (L'Aquila 2009 and Emilia 2012) highlighted the vulnerability of precast cladding panels, typically associated with a connection system not designed to account for displacement and rotation compatibility between the panels and the supporting structure. Experimental investigations were performed in the past to investigate the in‐plane performance of cladding panels and design recommendations have been made accordingly; however, in the case of out‐of‐plane seismic loads, the load demand is commonly evaluated in the design practice by means of formulations for nonstructural components. This paper summarizes the results obtained from parametric analyses conducted to estimate the out‐of‐plane load demand in column‐to‐column cladding panels typical of one‐storey commercial and industrial buildings. Empirical equations suitable for both new and existing panels are proposed and compared with the design equations given in Eurocode 8 and ASCE 7. The paper also considers the effects of the development of plastic hinges at the column base and of the roof flexibility on the load demand in panel‐to‐column connections. The roof flexibility may generate the torsion of the panels; consequently, an analytical procedure to account for such effects is proposed. Finally, general design recommendations are made.  相似文献   

19.
An existing two‐dimensional macroelement for reinforced concrete beam–column joints is extended to a three‐dimensional macroelement. The three‐dimensional macroelement for beam–column joints consists of six rigid interface plates and uniaxial springs for concrete, steel, and bond–slip, which model the inside of a beam–column joint. The mechanical models for the materials and the stiffness equation for the springs are also presented. To validate the model, we used test results from three slab–beam–column sub‐assemblages subjected to bi‐lateral cyclic load. It is revealed that the new joint model is capable of capturing the strength of beam–column joints and the bidirectional interaction in joint shear response, including the concentration of damage in the beam–column joint, the pinching nature in hysteretic behavior, the stiffness degradation, and strength deterioration resulting from cyclic and bidirectional loading. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

20.
The feasibility and efficiency of a seismic retrofit solution for existing reinforced concrete frame systems, designed before the introduction of modern seismic‐oriented design codes in the mid 1970s, is conceptually presented and experimentally investigated. A diagonal metallic haunch system is introduced at the beam–column connections to protect the joint panel zone from extensive damage and brittle shear mechanisms, while inverting the hierarchy of strength within the beam–column subassemblies and forming a plastic hinge in the beam. A complete step‐by‐step design procedure is suggested for the proposed retrofit strategy to achieve the desired reversal of strength hierarchy. Analytical formulations of the internal force flow at the beam–column‐joint level are derived for the retrofitted joints. The study is particularly focused on exterior beam–column joints, since it is recognized that they are the most vulnerable, due to their lack of a reliable joint shear transfer mechanism. Results from an experimental program carried out to validate the concept and the design procedure are also presented. The program consisted of quasi‐static cyclic tests on four exterior, ? scaled, beam–column joint subassemblies, typical of pre‐1970 construction practice using plain round bars with end‐hooks, with limited joint transverse reinforcement and detailed without capacity design considerations. The first (control specimen) emulated the as‐built connection while the three others incorporated the proposed retrofitted configurations. The experimental results demonstrated the effectiveness of the proposed solution for upgrading non‐seismically designed RC frames and also confirmed the applicability of the proposed design procedure and of the analytical derivations. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   