首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
A pumping test in a granite aquifer provides information about the interaction between the upper weathered zone and lower fractured zone. A radial flow numerical model is used to interpret the test and estimate aquifer parameters. This model successfully reproduces both the fractured zone response and the shallow weathered zone response which is characterised by increasing drawdown even after abstraction ceases. When the deep fractured aquifer was exploited, a serious decline in groundwater heads and yields occurred; this behaviour can be reproduced by the model. The model is then used to investigate the effective long-term exploitation of the aquifer and the results indicate that dug-cum-bore wells can be used for the safe and efficient exploitation of the aquifer resources.  相似文献   

2.
Fault zones are an important control on fluid flow, affecting groundwater supply, contaminant migration, and carbon storage. However, most models of fault seal do not consider fault zone cementation, despite the recognition that it is common and can dramatically reduce permeability. In order to study the field-scale hydrogeologic effects of fault zone cementation, we conducted a series of aquifer pumping tests in wells installed within tens of meters of the variably cemented Loma Blanca Fault, a normal fault in the Rio Grande Rift. In the southern half of the study area, the fault zone is cemented by calcite; the cemented zone is 2-8 m wide. In the center of the study area, the cemented fault zone is truncated at a buttress unconformity that laterally separates hydrostratigraphic units with a ∼40X difference in permeability. The fault zone north of the unconformity is not cemented. Constant rate pumping tests indicate that where the fault is cemented, it is a barrier to groundwater flow. This is an important demonstration that a fault with no clay in its core and similar sediment on both sides can be a barrier to groundwater flow by virtue of its cementation; most conceptual models for the hydrogeology of faults would predict that it would not be a barrier to groundwater flow. Additionally, the lateral permeability heterogeneity across the unconformity imposes another important control on the local flow field. This permeability discontinuity acts as either a no-flow boundary or a constant head boundary, depending on the location of pumping.  相似文献   

3.
鲁豫交界地区深井水位持续大幅度下降原因分析   总被引:4,自引:2,他引:2  
鲁豫交界地区豫01、11井和鲁27井等3口地震观测深井的水位于2006年后出现了准同步的异常下降变化,下降幅度3 ~12m不等.经调查落实,发现该地区近年来地热开采活动日益增强,开采量逐年增大,并且开采层与异常井水位观测层同属于奥陶系热储层.为此,本文依据聊城-兰考断裂带附近区域的水文地质构造特征,建立了三维地下水流动模型,基于周边地热开采量数据和相关含水层参数,运用有限差分方法计算了地热开采所引起的区域水位降落漏斗,并分析了水位下降异常的时间演化和空间分布特征.结果显示,聊城-兰考断裂带附近区域自1995年开始地热开采活动以来,其逐年增加的地热开采量与地震观测井水位的下降幅度之间存在较好的对应关系,分析认为鲁豫交界地区3口深井水位的准同步异常下降与周边地热开采活动有关.  相似文献   

4.
In this study, we attempted to analyse a drawdown pattern around a pumping well in an unconfined sandy gravelly aquifer constructed in a laboratory tank by means of both experimental and numerical modelling of groundwater flow. The physical model consisted of recharge, aquifer and discharge zones. Permeability and specific yield of the aquifer material were determined by Dupuit approximation under steady‐state flow and stepwise gravitational drainage of groundwater, respectively. The drawdown of water table in pumping and neighbouring observation wells was monitored to investigate the effect of no‐flow boundary on the drawdown pattern during pumping for three different boundary conditions: (i) no recharge and no discharge with four no‐flow boundaries (Case 1); (ii) no recharge and reservoir with three no‐flow boundaries (Case 2); (iii) recharge and discharge with two no‐flow boundaries (Case 3). Based on the aquifer parameters, numerical modelling was also performed to compare the simulated drawdown with that observed. Results showed that a large difference existed between the simulated drawdown and that observed in wells for all cases. The reason for the difference could be explained by the formation of a curvilinear type water table between wells rather than a linear one due to a delayed response of water table in the capillary fringe. This phenomenon was also investigated from a mass balance study on the pumping volume. The curvilinear type of water table was further evidenced by measurement of water contents at several positions in the aquifer between wells using time domain reflectometry (TDR). This indicates that the existing groundwater flow model applicable to an unconfined aquifer lacks the capacity to describe a slow response of water table in the aquifer and care should be taken in the interpretation of water table formation in the aquifer during pumping. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
Accurate representation of groundwater flow and solute transport requires a sound representation of the underlying geometry of aquifers. Faults can have a significant influence on the structure and connectivity of aquifers, which may allow permeable units to connect, and aquifers to seal when juxtaposed against lower permeability units. Robust representation of groundwater flow around faults remains challenging despite the significance of faults for flow and transport. We present a methodology for the inclusion of faults utilizing the unstructured grid features of MODFLOW-USG and MODFLOW 6. The method focuses on the representation of fault geometries using non-neighbor connections between juxtaposed layers. We present an illustration of the method for a synthetic fluvial aquifer. The combined impact of the heterogeneous aquifer and fault offset is clearly visible where channel features at different depths in the aquifer were connected at the fault. These results highlight the importance of representing fault features in groundwater flow models.  相似文献   

6.
The acceptability of the hypothesis of Darcian flow through a semiconfined carbonate aquifer was tested prior to running a multiple-day aquifer test in Pinellas County, Florida. The approach used to test the hypothesis was to run a number of hour-long aquifer tests at different discharges with drawdown measured at the same time during each test in two observation wells, one at 35 feet and the other at 733 feet from the pumped well. If the hypothesis were acceptable, a plot of drawdown versus discharge should describe a straight line. A linear relation was described in 15-minute and 1-hour data plots of drawdown versus discharge for both observation wells. Thus, the hypothesis of Darcian flow through the semiconfined carbonate aquifer was deemed acceptable. Drawdown data from the distant observation well collected during the following multiple-day aquifer test were then analyzed for aquifer-property values of transmissivity, storage coefficient, and leakance coefficient using standard methods. Discharge for the multiple-day test was within the discharge range of the hour-long tests.  相似文献   

7.
A new type of vertical circulation well (VCW) is used for groundwater dewatering at construction sites. This type of VCW consists of an abstraction screen in the upper part and an injection screen in the lower part of a borehole, whereby drawdown is achieved without net withdrawal of groundwater from the aquifer. The objective of this study is to evaluate the operation of such wells including the identification of relevant factors and parameters based on field data of a test site and comprehensive numerical simulations. The numerical model is able to delineate the drawdown of groundwater table, defined as free‐surface, by coupling the arbitrary Lagrangian–Eulerian algorithm with the groundwater flow equation. Model validation is achieved by comparing the field observations with the model results. Eventually, the influences of selected well operation and aquifer parameters on drawdown and on the groundwater flow field are investigated by means of parameter sensitivity analysis. The results show that the drawdown is proportional to the flow rate, inversely proportional to the aquifer conductivity, and almost independent of the aquifer anisotropy in the direct vicinity of the well. The position of the abstraction screen has a stronger effect on drawdown than the position of the injection screen. The streamline pattern depends strongly on the separation length of the screens and on the aquifer anisotropy, but not on the flow rate and the horizontal hydraulic conductivity.  相似文献   

8.
Data substantiating perched conditions in layered bedrock uplands are rare and have not been widely reported. Field observations in layered sedimentary bedrock in southwestern Wisconsin, USA, provide evidence of a stable, laterally extensive perched aquifer. Data from a densely instrumented field site show a perched aquifer in shallow dolomite, underlain by a shale-and-dolomite aquitard approximately 25 m thick, which is in turn underlain by sandstone containing a 30-m-thick unsaturated zone above a regional aquifer. Heads in water supply wells indicate that perched conditions extend at least several kilometers into hillsides, which is consistent with published modeling studies. Observations of unsaturated conditions in the sandstone over a 4-year period, historical development of the perched aquifer, and perennial flow from upland springs emanating from the shallow dolomite suggest that perched groundwater is a stable hydrogeologic feature under current climate conditions. Water-table hydrographs exhibit apparent differences in the amount and timing of recharge to the perched and regional flow systems; steep hydraulic gradients and tritium and chloride concentrations suggest there is limited hydraulic connection between the two. Recognition and characterization of perched flow systems have practical importance because their groundwater flow and transport pathways may differ significantly from those in underlying flow systems. Construction of multi-aquifer wells and groundwater withdrawal in perched systems can further alter such pathways.  相似文献   

9.
Changes of groundwater level, ranging from a fall of 11.10 m to a rise of 7.42 m, induced by thrust faulting during the 1999 Mw 7.6, Chi-Chi earthquake have been recorded in 276 monitoring wells in Taiwan. Most coseismic falls appeared near the seismogenic fault as well as other active faults, while coseismic rises prevailed away from the fault. Coseismic groundwater level rises and falls correlated fairly well with hypocentral distance in the vicinity of the thrust fault. We found a major difference of coseismic changes in wells of different depths at most multiple-well stations. The recovery process of coseismic groundwater level changes is associated with the confining condition of the aquifer. Cross-formational flow is likely to play an important role in groundwater level changes after the earthquake. In the hanging wall of the thrust fault, an abnormal decline of groundwater level was observed immediately before the earthquake. The underlying mechanism of the unique preseismic change warrants further investigation.  相似文献   

10.
The buried-valley aquifers that are common in the glacial deposits of the northern hemisphere are a typical case of the strip aquifers that occur in many parts of the world. Pumping from a narrow strip aquifer leads to much greater drawdown and much more distant drawdown effects then would occur in a sheet aquifer with a similar transmissivity and storage coefficient. Widely used theories for radial flow to wells, such as the Theis equation, are not appropriate for narrow strip aquifers. Previously published theory for flow to wells in semiconfined strip aquifers is reviewed and a practical format of the type curves for pumping-test analysis is described. The drawdown response of strip aquifers to pumping tests is distinctive, especially for observation wells near the pumped well. A case study is presented, based on extensive pumping test experience for the Estevan Valley Aquifer in southern Saskatchewan, Canada. Evaluation of groundwater resources in such buried-valley aquifers needs to take into account the unusually large drawdowns in response to pumping.  相似文献   

11.
In order to understand the flow pattern around a pumping well partially penetrating a vertically extensive aquifer, a specially designed pumping test was carried out in Pakistan. In this paper salient features of the test have been described. The spatial distributions of drawdown have been shown graphically. Some of the preliminary conclusions made from the drawdown pattern include:
  • • The distance beyond which the flow is likely to be horizontal increases with decrease in the degree of aquifer penetration.
  • • In equidistant observation wells open at different depths, (1) the drawdowns tend to merge at larger times, provided the observation point is located within the screened section of the aquifer; (2) the less the depth of penetration is, the earlier the drawdowns start merging; and (3) the initial rate of drawdown near the aquifer top is slow but catches up with time to exceed those at deeper points.
  相似文献   

12.
The objective of this study was to investigate whether 222Rn in groundwater can be used as a tracer for light non‐aqueous phase liquid (LNAPL) quantification at a field site treated by dual‐phase LNAPL removal. After the break of a pipeline, 5 ha of soil in the nature reserve Coussouls de Crau in southern France was contaminated by 5100 m3 of crude oil. Part of this oil seeped into the underlying gravel aquifer and formed a floating oil body of about 3.9 ha. The remediation consists of plume management by hydraulic groundwater barriers and LNAPL extraction in the source zone. 222Rn measurements were performed in 21 wells in and outside the source zone during 15 months. In uncontaminated groundwater, the radon activity was relatively constant and remained always >11 Bq/L. The variability of radon activity measurements in wells affected by the pump‐and‐skim system was consistent with the measurements in wells that were not impacted by the system. The mean activities in wells in the source zone were, in general, significantly lower than in wells upgradient of the source zone, owing to partitioning of 222Rn into the oil phase. The lowest activities were found in zones with high non‐aqueous phase liquid (NAPL) recovery. LNAPL saturations around each recovery well were furthermore calculated during a period of high groundwater level, using a laboratory‐determined crude oil–water partitioning coefficient of 38.5 ± 2.9. This yielded an estimated volume of residual crude oil of 309 ± 93 m3 below the capillary fringe. We find that 222Rn is a useful and cheap groundwater tracer for finding zones of good LNAPL recovery in an aquifer treated by dual‐phase LNAPL removal, but that quantification of NAPL saturation using Rn is highly uncertain.  相似文献   

13.
This paper develops a well function applicable to extraction of groundwater or soil vapor from a well under the most common field test conditions. The general well function (Perina and Lee, 2006) [12] is adapted to soil vapor extraction and constant head boundary at the top. For groundwater flow, the general well function now applies to an extraction well of finite diameter with uniform drawdown along the screen, finite-thickness skin, and partially penetrating an unconfined, confined, and leaky aquifer, or an aquifer underneath a reservoir. With a change of arguments, the model applies to soil vapor extraction from a vadose zone with no cover or with leaky cover at the ground surface. The extraction well can operate in specified drawdown (pressure for soil vapor) or specified flowrate mode. Frictional well loss is computed as flow-only dependent component of the drawdown inside the extraction well. In general case, the calculated flow distribution is not proportional to screen length for a multiscreen well.  相似文献   

14.
The interaction between a gaining stream and a water-table aquifer is studied at an outwash plain. The aquifer is hydraulically well connected to the stream. Pumping tests were carried out in 1997 and 1998 in two wells 60 m from the stream, screening different depths of the aquifer. Drawdown was measured on both sides of the stream. Hydraulic head, drawdown, and stream depletion data were analyzed using numerical flow models. Similar models were fitted to each of two different data sets: Model A was fitted to steady-state hydraulic head and streamflow gain data not influenced by pumping; and model B was fitted to drawdown data measured during the 1998 pumping test. Each calibrated model closely fits its calibration data; however, predictions were biased if model A was used to predict the calibration data of model B, and vice versa. To further test the models, they were used to predict streamflow depletion during the two pumping tests as well as the drawdown during the 1997 test. Neither of these data were used for calibration. Model A predicted the measured depletions fairly accurately during both tests, whereas the predicted drawdowns in 1997 were significantly larger than actually measured. Contrary to this, the 1997 drawdowns predicted by model B were nearly unbiased; the predicted depletions deviate significantly from the measured depletions in 1997, but they compare well with the observations in 1998. Thus, although field work and analyses were extensive and done carefully to develop a ground water flow model that could predict both drawdown and streamflow depletion, the model predictions are biased. Analyses indicate that the deviations between model and data may be because of error in the models' representations of either the release of water from storage or of the hydrology in the riparian zone.  相似文献   

15.
Tomas Perina 《Ground water》2021,59(3):438-442
Time-domain analytical solution for groundwater flow to a fully penetrating flowing well is derived using the same substitution technique used to re-derive (Perina 2010) the Theis (1935) equation and the approximate solution by Mishra and Guyonnet (1992) is confirmed. The exponential integral-based flowing well function is a computationally effective alternative to the original Jacob and Lohman (1952) solution in integral form. For a constant drawdown test, the ratio of drawdown at an observation well to the flowrate is equivalent to drawdown response to pumping at unit constant rate; the transformed observations can be analyzed using the Theis (1935) function. Analysis of field test shows that simultaneous fitting to measurements of flow from the test well and drawdown at an observation well results in more accurate and better resolved estimates of aquifer properties than fitting to flow observations only.  相似文献   

16.
Large proportions of rainwater and snowmelt infiltrate into the subsurface before contributing to stream flow and stream water quality. Subsurface flow dynamics steer the transport and transformation of contaminants, carbon, weathering products and other biogeochemistry. The distribution of groundwater ages with depth is a key feature of these flow dynamics. Predicting these ages are a strong test of hypotheses about subsurface structures and time-varying processes. Chlorofluorocarbon (CFC)-based groundwater ages revealed an unexpected groundwater age stratification in a 0.47 km2 forested catchment called Svartberget in northern Sweden. An overall groundwater age stratification, representative for the Svartberget site, was derived by measuring CFCs from nine different wells with depths of 2–18 m close to the stream network. Immediately below the water table, CFC-based groundwater ages of already 30 years that increased with depth were found. Using complementary groundwater flow models, we could reproduce the observed groundwater age stratification and show that the 30 year lag in rejuvenation comes from return flow of groundwater at a subsurface discharge zone that evolves along the interface between two soil types. By comparing the observed groundwater age stratification with a simple analytical approximation, we show that the observed lag in rejuvenation can be a powerful indicator of the extent and structure of the subsurface discharge zone, while the vertical gradient of the age-depth-relationship can still be used as a proxy of the overall aquifer recharge even when sampled in the discharge zone. The single age stratification profile measured in the discharge zone, close to the aquifer outlet, can reveal the main structure of the groundwater flow pattern from recharge to discharge. This groundwater flow pattern provides information on the participation of groundwater in the hydrological cycle and indicates the lower boundary of hydrological connectivity.  相似文献   

17.
《水文科学杂志》2013,58(3):543-555
Abstract

The contact between freshwater and seawater in coastal aquifers is studied using a relatively simple model for homogeneous aquifers. However, for real aquifers it is not so simple. The desalination plant built to supply water to the city of Almería is situated over the aquifer in the southern part of the River Andarax Delta. Its design capacity is 1100 L s?1, and it is supplied from boreholes pumping water from beneath the freshwater—seawater contact in this aquifer. Well logs kept over a period of two years have allowed us to accurately define the interface geometry of the freshwater—seawater contact. Lithological data collected from 31 boreholes have also indicated the existence of strata with low hydraulic conductivity, within others of high conductivity. During a simultaneous pumping test of six wells with 690 L s?1 total discharge, electrical conductivity measurements showed the influx of seawater 6–10 m below sea level and a drawdown of the interface in the piezometers closest to the pumping wells.  相似文献   

18.
The desert of eastern Libya forms one of the most arid regions of the Sahara. The Great Man‐Made River Project (GMRP) was established. It transports millions of cubic meters of water a day from desert wellfields to the coastal cities, where over 80% of the population lives. The Tazerbo Wellfield is one of the wellfields designed within the GMRP, delivering water to the eastern coast of Libya through an underground pipe network. Tazerbo Wellfield consists of 108 production wells; each well was designed to pump 100 L/s. The planned total groundwater withdrawal from all wells is 1 million m3/d. The deep sandstone aquifer (Nubian sandstone) is covered by a thick mudstone‐siltstone aquitard and is being heavily pumped. The aquifer and fine‐grained sediments of the aquitard may be compacted resulting in land subsidence as a result of high exploitation. Local sinkholes have developed in the area of Tazerbo since the start of the pumping from the wellfield in 2004. These sinkholes have been caused mainly by lowering of the piezometric heads due to the withdrawal of groundwater. In this study, a hydrogeological investigation is presented about the effect of large groundwater pumping from the Nubian sandstone aquifer in Tazerbo Wellfield, SE Libya, based on physical parameters for 108 production wells and 23 observation wells.  相似文献   

19.
Data from a large-scale canal-drawdown test were used to estimate the specific yield (sy) of the Biscayne Aquifer, an unconfined limestone aquifer in southeast Florida. The drawdown test involved dropping the water level in a canal by about 30 cm and monitoring the response of hydraulic head in the surrounding aquifer. Specific yield was determined by analyzing data from the unsteady portion of the drawdown test using an analytical stream-aquifer interaction model (Zlotnik and Huang 1999). Specific yield values computed from drawdown at individual piezometers ranged from 0.050 to 0.57, most likely indicating heterogeneity of specific yield within the aquifer (small-scale variation in hydraulic conductivity may also have contributed to the differences in sy among piezometers). A value of 0.15 (our best estimate) was computed based on all drawdown data from all piezometers. We incorporated our best estimate of specific yield into a large-scale two-dimensional numerical MODFLOW-based ground water flow model and made predictions of head during a 183-day period at four wells located 337 to 2546 m from the canal. We found good agreement between observed and predicted heads, indicating our estimate of specific yield is representative of the large portion of the Biscayne Aquifer studied here. This work represents a practical and novel approach to the determination of a key hydrogeological parameter (the storage parameter needed for simulation and calculation of transient unconfined ground water flow), at a large spatial scale (a common scale for water resource modeling), for a highly transmissive limestone aquifer (in which execution of a traditional pump test would be impractical and would likely yield ambiguous results). Accurate estimates of specific yield and other hydrogeological parameters are critical for management of water supply, Everglades environmental restoration, flood control, and other issues related to the ground water hydrology of the Biscayne Aquifer.  相似文献   

20.
A covariance-based model-fitting approach is often considered valid to represent field spatial variability of hydraulic properties. This study examines the representation of geologic heterogeneity in two types of geostatistical models under the same mean and spatial covariance structure, and subsequently its effect on the hydraulic response to a pumping test based on 3D high-resolution numerical simulation and field data. Two geostatistical simulation methods, sequential Gaussian simulation (SGS) and transition probability indicator simulation (TPROGS) were applied to create conditional realizations of alluvial fan aquifer systems in the Lawrence Livermore National Laboratory (LLNL) area. The simulated K fields were then used in a numerical groundwater flow model to simulate a pumping test performed at the LLNL site. Spatial connectivity measures of high-K materials (channel facies) captured connectivity characteristics of each geostatistical model and revealed that the TPROGS model created an aquifer (channel) network having greater lateral connectivity. SGS realizations neglected important geologic structures associated with channel and overbank (levee) facies, even though the covariance model used to create these realizations provided excellent fits to sample covariances computed from exhaustive samplings of TPROGS realizations. Observed drawdown response in monitoring wells during a pumping test and its numerical simulation shows that in an aquifer system with strongly connected network of high-K materials, the Gaussian approach could not reproduce a similar behavior in simulated drawdown response found in TPROGS case. Overall, the simulated drawdown responses demonstrate significant disagreement between TPROGS and SGS realizations. This study showed that important geologic characteristics may not be captured by a spatial covariance model, even if that model is exhaustively determined and closely fits the exponential function.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号