首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A modified force analogy method (MFAM) is developed to simulate the nonlinear inelastic response of reinforced concrete (RC) structures. Beam–column elements with three different plastic mechanisms are utilized to simulate inelastic response caused by moment and shear force. A multi‐linear hysteretic model is implemented to simulate the nonlinear inelastic response of RC member. The P‐Δ effect of the structure is also addressed in MFAM. Static and dynamic inelastic response of structure, damage condition and failure type for structural element, structural limit state and collapse time can also be simulated using MFAM. Compared with the general algorithm, the MFAM provides less computational time especially in the case of large structural system. It is also easier to be written as computer program. Three test data groups, which include cyclic loading test data of a non‐ductile RC bridge column, a two‐storey RC frame, and dynamic collapse test data of a non‐ductile RC portal frame, are selected to confirm the effectiveness of applying MFAM to simulate the inelastic behaviour of structures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

2.
Using a newly introduced ductile low-rise shear wall with vertical keyways, a seismic resistance design approach for a practical type of composite structure, which consists of a reinforced concrete frame in the bottom floors and masonry structures in the upper floors, has been presented. The purpose of the new design approach is to improve the earthquake resistance of the whole structure by increasing the energy dissipation capacity in the bottom part of the structure. Non-linear analysis shows that, by adopting the newly proposed ductile low-rise shear wall in the bottom of the structure, the lateral deflection of the structure is not much more than that of a structure using conventional solid low-rise shear walls under a small or moderate earthquake excitation, and that even under the attack of a severe earthquake, a stable structural response can be expected for the proposed structure. Thus it is easy for such a structure to achieve the design objective of ‘minor damage in a small earthquake and prevention of collapse in a severe earthquake’ and the design method is of practical value for similar types of composite structures.  相似文献   

3.
Recent studies reveal that R/C structural members subjected to biaxial flexure due to two-dimensional earthquake excitation can deform much more than would be predicted by conventional one-dimensional response analysis. The biaxial flexure may therefore have a significant effect on the dynamic collapse process of structures subjected to intense ground motions. The present paper is intended to develop a new formulation of the two-dimensional restoring force model of R/C columns acted upon by biaxial bending moments, and to discuss the dynamic response properties of R/C structures. The model considered is a two-dimensional extension of various non-linear models for one-dimensional response analysis, including the degrading trilinear stiffness model which is one of the simpler idealizations of the restoring force characteristics of flexural-failure-type R/C structures. The modelling validity is then examined by comparison with experimental data on the biaxial bending behaviour of R/C columns. Calculations are made to study the role of different system properties on the influence of inelastic biaxial bending on the dynamic structural response. It is shown that the inelastic biaxial effect is generally significant and, in some cases, critical in the case of R/C structures with stiffness-degrading properties, while the effect is not so important for the non-degrading inelastic cases.  相似文献   

4.
Recent studies have addressed the computation of fragility curves for mainshock (MS)‐damaged buildings. However, aftershock (AS) fragilities are generally conditioned on a range of potential post‐MS damage states that are simulated via static or dynamic analyses performed on an intact building. Moreover, there are very few cases where the behavior of non‐ductile reinforced concrete buildings is analyzed. This paper presents an evaluation of AS collapse fragility conditioned on various return periods of MSs, allowing for the rapid assessment of post‐earthquake safety variations based solely on the intensity of the damaging earthquake event. A refined multi‐degree‐of‐freedom model of a seven‐storey non‐ductile building, which includes brittle failure simulations and the evaluation of a system level collapse, is adopted. Aftershock fragilities are obtained by performing an incremental dynamic analysis for a number of MS–AS ground motion sequences and a variety of MS intensities. The AS fragilities show that the probability of collapse significantly increases for higher return periods for the MS. However, this result is mainly ascribable to collapses occurred during MSs. When collapse cases that occur during a MS are not considered in the assessment of AS collapse probability, a smaller shift in the fragility curves is observed as the MS intensity increases. This result is justified considering the type of model and collapse modes introduced, which strongly depend on the brittle behavior of columns failing in shear or due to axial loads. The analysis of damage that is due to MSs when varying the return period confirms this observation. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

5.
A new simplified model for analysis and design of multistorey buildings is developed. The model is based on a single super-element per building storey capable of representing the elastic and inelastic properties of the storey. This is done by matching the stiffness matrices and ultimate yield surface of the storey with that of the element; this surface relates storey shear and storey torque. For practical convenience, these surfaces are parametrized in terms of seven important physical parameters controlling the seismic response of asymmetric structures. Several numerical studies showed that the accuracy of the super-element model is satisfactory for most design purposes; the errors in peak responses are expected to be less than 20 per cent for most practical structures. Among the important advantages of this simplified model is that the time required in formulating, analysing and interpreting the structural model and its response is at least an order of magnitude smaller than for any conventional 3-D inelastic model. This enables the engineer to try different structural configurations and, thus, produce designs that have the desired seismic behaviour and are cost-effective. Furthermore, it has been shown through a multistorey building example that the super-element model is a powerful tool for conceptual design of a building. In spite of its simplicity, the model uses an accurate representation of the storey-shear and torque surfaces, which enables it to capture the fundamental features controlling the inelastic behaviour of the building.  相似文献   

6.
7.
The non‐stationary Functional Series time‐dependent autoregressive moving average (TARMA) modelling and simulation of earthquake ground motion is considered. Full Functional Series TARMA models, capable of modelling both resonances and antiresonances, are examined for the first time via a novel mixed parametric/non‐parametric estimation scheme, and critical comparisons with pure TAR and recursive ARMA (RARMA)‐recursive maximum likelihood (RML) adaptive filtering type modelling are made. The study is based upon two California ground motion signals: a 1979 El Centro accelerogram and a 1994 Pacoima Dam accelerogram. A systematic analysis, employing various functional subspaces and model orders, leads to two Haar function based models: a TARMA(2,4)8 model for the El Centro case and a TARMA(6,2)10 model for the Pacoima Dam case. Both models are formally validated and their simulation (synthesis) capabilities are demonstrated via Monte Carlo experiments focusing on important time domain signal characteristics. The Functional Series TAR/TARMA models are shown to achieve parsimony, as well as superior accuracy and simulation capabilities, over their RARMA counterparts. Copyright © 2001 John Wiley & Sons Ltd.  相似文献   

8.
This paper presents the results of a multi‐level pseudo‐dynamic seismic test program that was performed to assess the performance of a full‐scale three‐bay, two‐storey steel–concrete composite moment‐resisting frame built with partially encased composite columns and partial‐strength beam‐to‐column joints. The system was designed to develop a ductile response in the joint components of beam‐to‐column joints including flexural yielding of beam end plates and shear yielding of the column web panel zone. The ground motion producing the damageability limit state interstorey drift caused minor damage while the ultimate limit state ground motion level entailed column web panel yielding, connection yielding and plastic hinging at the column base connections. The earthquake level chosen to approach the collapse limit state induced more damage and was accompanied by further column web panel yielding, connection yielding and inelastic phenomena at column base connections without local buckling. During the final quasi‐static cyclic test with stepwise increasing displacement–amplitudes up to an interstorey drift angle of 4.6%, the behaviour was ductile although cracking of beam‐to‐end‐plate welds was observed. Correlations with numerical simulations taking into account the inelastic cyclic response of beam‐to‐column and column base joints are also presented in the paper together. Inelastic static pushover and time history analysis procedures are used to estimate the structural behaviour and overstrength factors of the structural system under study. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
A three‐dimensional model for approximate inelastic analysis of buildings is presented herein. The model is based on a single macro‐element per building storey. The inelastic properties of the model are characterized by the so‐called ultimate storey shear and torque (USST) surfaces. Different algorithms for the construction of these surfaces, as well as their applications in building modelling, are presented and discussed. Two alternative procedures are developed to integrate the force‐deformation constitutive relationship of the macro‐elements. The first one follows the exact trajectory of the load path of the structure on the USST, and the second uses linear programming without ever forming the USST surface. The accuracy of the model and integration procedure is evaluated by means of the earthquake response of single‐storey systems. The model and integration procedure developed is finally used to compute the inelastic response of a seven‐storey R/C building. The results of this investigation show that the model proposed, although approximate, can be effective in estimating the inelastic deformation demand of a building. It also enables the engineer to capture and interpret important features of the three‐dimensional inelastic response of a structure even before performing any inelastic dynamic analysis. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

10.
A systematic seismic risk study has been performed on some typical precast industrial buildings that consists of assemblages of cantilever columns with high shear‐span ratios connected to an essentially rigid roof system with strong pinned connections. These buildings were designed according to the requirements of Eurocode 8. The numerical models and procedures were modified in order to address the particular characteristics of the analyzed system. They were also verified by pseudo‐dynamic and cyclic tests of full‐scale large buildings. The intensity measure (IM)‐based solution strategy described in the PEER methodology was used to estimate the seismic collapse risk in terms of peak ground acceleration capacity and the probability of exceeding the global collapse limit state. The effect of the uncertainty in the model parameters on the dispersion of collapse capacity was investigated in depth. Reasonable seismic safety (as proposed by the Joint Committee on Structural Safety) was demonstrated for all the regular single‐storey precast industrial buildings addressed in this study. However, if the flexural strength required by EC8 was exactly matched, and the additional strength, which results from minimum longitudinal reinforcement, was disregarded as well as large dispersion in records was considered, the seismic risk might in some cases exceed the acceptable limits. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Studied in this paper is the inelastic seismic behaviour of asymmetric-plan buildings using the histories of base shear and torque. The first step in understanding this behaviour is to construct the base shear and torque surface (BST) for the building, which represents all combinations of shear and torque that applied statically lead to collapse of the structure. Several factors controlling the shape of this surface, such as strength eccentricity and bidirectional ground motion, are identified. Also, their effects on the building responses are studied considering several structural configurations. The results obtained show that the BST surface, in conjunction with the base-shear and torque histories, provides a useful conceptual framework for understanding the behaviour of asymmetric systems. Furthermore, using these surfaces, relevant aspects of the behaviour and design of such buildings become apparent even before dynamic analysis of the structure.  相似文献   

12.
While much effort has been spent on analysis of individual structures, building class seismic damage estimators, of value in disaster planning, code-writing, city planning, national hazards policy formulation, etc., have been little investigated. Based largely on data from Sendai City, Japan in the 12 June, 1978 Miyagiken-oki earthquake (ML = 7.4), estimators of seismic damage for low- and mid-rise buildings in urban Japan have been determined. For low-rise buildings, based on damage to over 60,000 buildings, damage ratios for onset of damage and collapse and for cost of damage are found to correlate best with response spectra at 0.75 s. Using published test data and average building properties, a seismic damage model explains the low-rise building behaviour and permits examination of the effect of structural changes on the estimated damage. For mid-rise buildings, damage states (0: none, 4: total) are determined as a function of maximum storey displacement, based on published natural period determinations (pre- and post-earthquake) for 189 mid-rise buildings in Sendai. The effects of structural changes on expected damage can also be estimated. With these two building class damage estimators, a large part of future seismic damage to urban Japan can be estimated, as well as the effects of various mitigation measures.  相似文献   

13.
A procedure for displacement‐based seismic design (DBD) of reinforced concrete buildings is described and applied to a 4‐storey test structure. The essential elements of the design procedure are: (a) proportioning of members for gravity loads; (b) estimation of peak inelastic member deformation demands in the so‐designed structure due to the design (‘life‐safety’) earthquake; (c) revision of reinforcement and final detailing of members to meet these inelastic deformation demands; (d) capacity design of members and joints in shear. Additional but non‐essential steps between (a) and (b) are: (i) proportioning of members for the ULS against lateral loads, such as wind or a serviceability (‘immediate occupancy’) earthquake; and (ii) capacity design of columns in flexure at joints. Inelastic deformation demands in step (b) are estimated from an elastic analysis using secant‐to‐yield member stiffnesses. Empirical expressions for the deformation capacity of RC elements are used for the final proportioning of elements to meet the inelastic deformation demands. The procedure is applied to one side of a 4‐storey test structure that includes a coupled wall and a two‐bay frame. The other side is designed and detailed according to Eurocode 8. Major differences result in the reinforcement of the two sides, with significant savings on the DBD‐side. Pre‐test calculations show no major difference in the seismic performance of the two sides of the test structure. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

14.
Post‐earthquake reconnaissance has reported the vulnerability of older reinforced concrete (RC) columns lacking details for ductile response. Research was undertaken to investigate the full‐range structural hysteretic behavior of older RC columns. A two‐dimensional specimen frame, composed of nonductile and ductile columns to allow for load redistribution, was subjected to a unidirectional base motion on a shaking table until global collapse was observed. The test demonstrates two types of column failure, including flexure‐shear and pure flexural failure. Test data are compared with various simplified assessment models commonly used by practicing engineers and researchers to identify older buildings that are at high risk of structural collapse during severe earthquake events. Comparison suggests that ASCE/SEI 41‐06 produces very conservative estimates on load–deformation relations of flexure‐shear columns, while the recently proposed ASCE/SEI 41‐06 update imposes significant modifications on the predictive curve, so that improved accuracy has been achieved. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
This study describes the seismic performance of an existing five storey reinforced concrete building which represents the typical properties of low-rise non-ductile buildings in Turkey. The effectiveness of shear walls and the steel bracings in retrofitting the building was examined through nonlinear static and dynamic analyses. By using the nonlinear static analysis, retrofitted buildings seismic performances under lateral seismic load were compared with each other. Moreover, the performance points and response levels of the existing and retrofitting cases were determined by way of the capacity-spectrum method described in ATC-40 (1996). For the nonlinear dynamic analysis the records were selected torepresent wide ranges of duration and frequency content. Considering the change in the stiffness and the energy dissipation capacities, the performance of the existing and retrofitted buildings were evaluated in terms of story drifts and damage states. It was found that each earthquake record exhibited its own peculiarities, dictated by frequency content, duration, sequence of peaks and their amplitude. The seismic performance of retrofitted buildings resulted in lower displacements and higher energy dissipation capacity depending mainly on the properties of the ground motions and the retrofitting strategies. Moreover, severe structural damage (irreparable or collapse) was observed for the existing building. However, buildings with retrofit alternatives exhibited lower damage levels changing from no damage to irreparable damage states.  相似文献   

16.
The dynamic, bi-linear response behaviour of a series of eight storey shear buildings subjected to simulated earthquake excitation is studied. The specific objective of the investigation is to determine under what conditions a yielding first storey can adequately protect the upper storeys from significant yielding. Two classes of buildings are considered: stiff (0.5 sec period) and flexible (2.0 sec period), and the basic parameters considered in the yielding first storey are the yield force level and the bi-linear stiffness. The results demonstrate that a very low yield force level and an essentially perfectly plastic yielding mechanism are required in the first storey to provide effective protection to the superstructure. Moreover, the required displacement capacity of such an effective first storey mechanism is found to be very large.  相似文献   

17.
Study of the data from the extensively instrumented buildings in the 1987 Whittier Narrows earthquake suggests that torsional modes probably were excited in buildings that outwardly appear quite symmetric. Accordingly this study involves: (i) investigation of the observed response of two low-rise buildings in both the elastic and moderately inelastic domains, (ii) comparison of such behaviour with the results obtained from modelling studies, and (iii) examination of the possible effects arising from stronger shaking. The study was directed towards attempting to provide a partial answer to the critical question of whether or not the torsional response was important in the gross total response of these low-rise buildings, and to what extent torsional concepts should be considered in design. Also the numerical results were extrapolated to examine the survivability of the same buildings if subjected to a somewhat stronger earthquake. The ultimate goal was to contribute insight to the practical guidelines for design and analysis of low-rise buildings subjected to strong ground motion.  相似文献   

18.
Seismic behaviour of masonry buildings, built of low compressive strength units, is discussed. Although such materials have already been tested and approved for use from mechanical and thermal insulation point of view, the knowledge regarding their structural behaviour is still lacking. In order to investigate the resistance and deformation capacity of this particular type of masonry construction in seismic conditions, a series of eight walls and model of a two-storey full scale confined masonry building have been tested by subjecting the specimens to cyclic shear loads. All tests were conducted under a combination of constant vertical load and quasi static, cyclically imposed horizontal load. The behaviour of tested specimens was of typical shear type. Compared with the behaviour of plain masonry walls, the presence of tie-columns resulted into higher resistance and displacement capacity, as well as smaller lateral resistance degradation. The response of the model was determined by storey mechanism with predominant shear behaviour of the walls and failure mechanism of the same type as in the case of individual confined masonry walls. Adequate seismic behaviour of this particular masonry structural type can be expected under the condition that the buildings are built as confined masonry system with limited number of stories.  相似文献   

19.
This paper deals with seismic analysis of plan‐asymmetric r/c frame multi‐storey buildings. Non‐linear numerical analyses are carried out by using a lumped plasticity model for beams and a multi‐spring model for columns, the latter one introduced to account for axial force–biaxial bending moment interaction. A comparison between numerical analyses and experimental test results is reported in order to calibrate the numerical model, showing that the adopted model is very suitable. In order to study the effects of the earthquake orthogonal component, the seismic response of the modelled structure under uni‐directional excitation is compared to the one under bi‐directional excitation. Such comparison shows that the maximum base shear and the top displacement are not very sensitive to the presence of the orthogonal component, which, conversely, leads to large increase in the column plastic excursions. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
The inelastic earthquake response of eccentric, multistorey, frame‐type, reinforced concrete buildings is investigated using three‐ and five‐storey models, subjected to a set of 10, two‐component, semi‐artificial motions, generated to match the design spectrum. Buildings designed according to the EC8 as well as the UBC‐97 code were included in the investigation. It is found that contrary to what the simplified one‐storey, typical, shear‐beam models predict, the so‐called ‘flexible’ side frames exhibit higher ductility demands than the ‘stiff’ side frames. The substantial differences in such demands between the two sides suggest a need for reassessment of the pertinent code provisions. This investigation constitutes one of the first attempts to study the problem of inelastic torsion by means of realistic, multistorey inelastic building models. Additional studies with similar or even more refined idealizations will certainly be required to arrive at definite results and recommendations for possible code revisions. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号