首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Among the resisting systems suitable for the design of ductile steel structures, Eurocode 8 proposes MRFs and EBFs. The formers are considered more efficient in terms of ductility, but they suffer a strong weakness in the lateral stiffness, with following cumbersome design procedures to avoid excessive lateral displacements maintaining a quite high ductile behaviour under seismic actions. Often, the design process leads to not optimized structural members, oversized with respect to the minimum seismic requirements due to lateral deformation limitations. EBFs combine high lateral stiffness, due to bracing elements, and high dissipative capacities, provided by the plastic hinges developed in links. Eurocode 8 proposes a design procedure for EBF structures in which iterative checks are required to design links with a defined level resistance dependent on all the other links’ strength. The present paper investigates the seismic behaviour of EBFs using Incremental Dynamic Analyses (IDA) to explore their mechanical response under increasing seismic action. IDAs are executed considering the influence of variability of steel mechanical properties on the behaviour of EBFs, using seven artificial accelerograms according to Eurocode 8. The aims of IDAs are the probabilistic assessment of the response of the system with respect to the variability of the material properties, the analysis of structural safety and the ability of the structures to internally redistribute plastic phenomena during the earthquake. Structural safety conditions will be defined according to a multi-level performance approach. The paper presents also some final suggestions for possible improvements and design simplifications.  相似文献   

2.
Building structures are typically designed using the assumption that the floor systems serve as a rigid diaphragm between the vertical elements of the lateral load‐resisting system. However, long‐floor span structures with perimeter lateral load‐resisting systems possess diaphragms which behave quite flexibly. The dynamic behaviour of such structures is dissimilar to the behavior expected of typical structures. This difference can lead to unexpected force and drift patterns. If force levels are sufficiently under‐estimated, inelastic diaphragm behaviour can occur, exacerbating the effects of diaphragm flexibility. Such response may lead to a non‐ductile diaphragm failure or structural instability due to high drift demands in the gravity system. Analytical models were developed which capture the diaphragm flexibility of structures with long‐floor spans and perimeter lateral‐systems. Modal examination and time‐history analyses were performed to determine the effect of diaphragm flexibility and diaphragm inelastic behaviour on the dynamic behaviour of these structures. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
A series of parametrically defined experimental model structures has been tested under earthquake base loading using the SERC national U.K. earthquake simulator. The models have been designed with variable ratios of torsional to lateral stiffness, and with both symmetric and asymmetric mass distributions. This paper first describes the tests carried out to determine the basic dynamic model properties and the establishment of idealized analytical models which give accurate predictions of model behaviour under steady-state loading and free-vibration conditions. Secondly, a detailed discussion is made of the two highly coupled structural models having uncoupled torsional to lateral frequency ratio Rf = 1.2, commenting on the ability of the modal analysis procedures to predict accurately the maximum recorded responses. It is concluded that the theory underestimates the significance of the fundamental torsional mode of vibration in the combined structural response, and overestimates the contribution of the first lateral mode. These effects compensate each other on the side of the structure which is most severely affected by torsional response, but produce large inaccuracies on the side of the building which is commonly assumed to be affected beneficially by torsional coupling.  相似文献   

4.
To improve the seismic performance of masonry structures, confined masonry that improves the seismic resistance of masonry structures by the confining effect of surrounding bond beams and tie columns is constructed. This study investigated the earthquake resisting behaviour of confined masonry structures that are being studied and constructed in China. The structural system consists of unreinforced block masonry walls with surrounding reinforced concrete bond beams and tie columns. The characteristics of the structure include: (1) damage to blocks is reduced and brittle failure is avoided by the comparatively lower strength of the joint mortar than that of the blocks, (2) the masonry walls and surrounding reinforced concrete bond beams and tie columns are securely jointed by the shear keys of the tie columns. In this study, wall specimens made of concrete blocks were tested under a cyclic lateral load and simulated by a rigid body spring model that models non‐linear behaviour by rigid bodies and boundary springs. The results of studies outline the resisting mechanism, indicating that a rigid body spring model is considered appropriate for analysing this type of structure. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

5.
The study of the torsional response of buildings in the inelastic range of behaviour is of great interest since the ability of structures to resist strong earthquakes mainly relies on their ductility and capacity for energy dissipation. Furthermore, an examination of the performance of structures during past earthquakes demonstrates that plan-asymmetric buildings suffered greater damage due to torsional response. The paper deals with this subject by analysing a model which idealizes a one-storey building with resisting elements oriented along two perpendicular directions. In addition to the parameters of the elastic behaviour, the inelastic system response depends on full yield capacity and plan-wise strength distribution. The influence of the criterion adopted for the design of resisting elements on local ductility demand and damage has been evaluated by parametric analysis. In particular, a comparison has been carried out between systems with equal design levels for all elements and systems with design levels dependent on the element location. For a given elastic behaviour and total capacity, the strength distributions in plan have been defined which minimize ductility demand and structural damage. Finally, based on these findings, responses from models designed according to several seismic codes have been compared.  相似文献   

6.
Pounding between adjacent bridge structures with insufficient separation distance has been identified as one of the primary causes of damage in many major earthquakes. It takes place because the closing relative movement is larger than the structural gap provided between the structures. This relative structural response is controlled not only by the dynamic properties of the participating structures but also by the characteristics of the ground excitations. The consequence of the spatial variation of ground motions has been studied by researchers; however, most of these studies were performed numerically. The objective of the present research is to experimentally evaluate the influence of spatial variation of ground motions on the pounding behaviour of three adjacent bridge segments. The investigation is performed using three shake tables. The input spatially varying ground excitations are simulated based on the New Zealand design spectra for soft soil, shallow soil and strong rock using an empirical coherency loss function. Results confirm that the spatially nonniform ground motions increase the relative displacement of adjacent bridge girders and pounding forces. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Complex seismic behaviour of soil–foundation–structure (SFS) systems together with uncertainties in system parameters and variability in earthquake ground motions result in a significant debate over the effects of soil–foundation–structure interaction (SFSI) on structural response. The aim of this study is to evaluate the influence of foundation flexibility on the structural seismic response by considering the variability in the system and uncertainties in the ground motion characteristics through comprehensive numerical simulations. An established rheological soil‐shallow foundation–structure model with equivalent linear soil behaviour and nonlinear behaviour of the superstructure has been used. A large number of models incorporating wide range of soil, foundation and structural parameters were generated using a robust Monte‐Carlo simulation. In total, 4.08 million time‐history analyses were performed over the adopted models using an ensemble of 40 earthquake ground motions as seismic input. The results of the analyses are used to rigorously quantify the effects of foundation flexibility on the structural distortion and total displacement of the superstructure through comparisons between the responses of SFS models and corresponding fixed‐base (FB) models. The effects of predominant period of the FB system, linear vs nonlinear modelling of the superstructure, type of nonlinear model used and key system parameters are quantified in terms of different probability levels for SFSI effects to cause an increase in the structural response and the level of amplification of the response in such cases. The results clearly illustrate the risk of underestimating the structural response associated with simplified approaches in which SFSI and nonlinear effects are ignored. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
The response of structures subjected to seismic actions is always influenced by P–Δ effects. The importance of this effect is generally modest for structures experiencing an elastic response but often relevant for structures responding well within the inelastic range of behaviour. Seismic codes indicate that P–Δ effects may be counterbalanced through an increase in the structural strength required by a first order analysis. This increase is calculated by means of a strength amplification factor. The expressions suggested in codes for this factor are simplistic and often criticized by researchers. In this paper, the effectiveness of some of the provisions reported in the literature or suggested in seismic codes is evaluated on single degree of freedom systems with different periods of vibration. As suggested by past studies, attention is focused on the influence of the interstorey drift sensitivity coefficient, significant duration of the ground motion, class of the site soil, displacement ductility and equivalent viscous damping ratio of the system. Finally, an accurate expression of the strength amplification factor is proposed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
This study aims to determine the influence of torsional coupling on the inelastic response of a series of models representing typical structural configurations in real buildings. The lake bed (SCT) east-west component of the 1985 Mexico City earthquake was employed in the analysis, and is representative of a severe ground motion known to have induced large inelastic structural deformations in a high proportion of those buildings having asymmetrical distributions of stiffness and/or strength. Material non-linearity in lateral load-resisting elements has been defined using a hysteretic Ramberg-Osgood model. Structural eccentricities have been introduced into the building models by (i) asymmetrical distributions of stiffness and/or strength, (ii) asymmetrical configuration of lateral load-resisting elements, or (iii) varying post-elastic material behaviour in the resisting elements. The dynamic inelastic response of these models has been obtained by a numerical integration of the relevant equations of motion, expressed in a non-dimensional incremental form.

In the elastic range, the results correlate well with those of previous studies. In the inelastic range, it is concluded that the peak ductility demand of the worst-affected element increases with the ground excitation level across the range of building periods considered, and that the influence of torsional coupling on the key response parameters is model dependent. Most significantly, the strength eccentricity relative to the centre of mass has been shown to influence the peak edge displacement response more than conventionally employed stiffness eccentricity.  相似文献   


10.
Seismic design of extended pile‐shafts requires a careful consideration of the influence of the surrounding soil on the overall response of the soil–pile system. In this paper, a procedure that incorporates soil properties into the process is developed for preliminary seismic design of extended pile‐shafts. The method follows the well‐accepted approach of using a force reduction factor to determine the lateral strength of the structure. The procedure involves an iterative process to arrive at the required amount of longitudinal reinforcement. Other outcomes of the procedure include the appropriate lateral stiffness and strength, as well as an estimation of the local curvature demand and ultimate drift ratio that can be used to ensure a satisfactory lateral response. The design procedure is capable of providing reliable results for a practical range of structural and soil properties. The versatility of the procedure is illustrated using two numerical examples of extended pile‐shafts constructed in different soil sites. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

11.
This paper presents qualitative investigations on the energy behaviour of structures into which hysteretic dampers are incorporated. Emphasis was given to the ratio of the structural stiffness after the yielding of hysteretic dampers to the initial elastic stiffness, with a premise that this ratio, termed α in this study, tends to be large for structures with hysteretic dampers. Structures concerned were represented by discrete spring–mass systems having bilinear restoring force behaviour, in which the second stiffness relative to the initial stiffness is α. It was found that with the increase of α the total input energy tends to increase, but the increase is confined to a narrow range of natural periods. Both the total input energy and hysteretic energy were found to become less sensitive to the yield strength with the increase of α. A simple formula was also proposed to estimate the maximum deformation given the knowledge of the hysteretic energy. Analysis of MDOF systems revealed that, even when α is large, the total input energy and hysteretic energy for MDOF systems are approximately the same as those of the equivalent SDOF system, and the hysteretic energy can be distributed uniformly over the stories if α is large.  相似文献   

12.
An aluminium beam shear-link is developed for earthquake-resistant structures. The aluminium beam is designed to yield in shear mode to limit the maximum lateral force which is transmitted to primary structural members and to provide significant energy dissipation potential. Aluminium was chosen because of its low yield strength, which enables the use of thicker webs, reducing the problems of web buckling. Cyclic load tests on medium scale (1:4) models were conducted to study the hysteretic behaviour and energy dissipation potential of shear-links made of two alloys of aluminium (3003-O and 6061-O). The links were also tested at faster rates (cycling frequencies of 5, 10 and 17 Hz) to determine the effect of strain rate. The links exhibited very ductile shear yielding and excellent energy dissipation capacity. Unpinched and full hysteresis loops were observed until 10 per cent shear strain, and a relatively small influence of strain rates was observed on the link's performance. Simple design equations are developed to proportion these shear-links, using data from the cyclic load tests. In chevron-type braced systems, the shear-link is sandwiched between the tops of diagonal braces and a girder from the floor above, resulting in yielding at a lateral force less than that required to buckle the compression brace. A Shear-Link Braced Frame (SLBF) system was designed and its seismic performance was compared to that of an Ordinary Concentric Braced Frame (OCBF) with chevron braces. The SLBF system demonstrated more uniform distribution of storey drifts, reduced base shear, and a larger energy dissipation capacity per unit drift. © 1998 John Wiley & Sons, Ltd.  相似文献   

13.
Constant-ductility strength demand spectra for seismic design of structures   总被引:1,自引:0,他引:1  
In displacement-based seismic design, constant-ductility strength demand spectra (CDSDS) are very useful for preliminary design of new structures where the global displacement ductility capacity is known. The CDSDS can provide the required inelastic lateral strength of new structures from the required elastic lateral strength. Based on a statistical study of nonlinear time-history for an SDOF system, the mean CDSDS corresponding to four site conditions are presented and approximate expressions of the inelastic spectra are proposed, which are functions of the structural period and ductility level. The effects of site conditions, structural period, level of ductility, damping and post-yield stiffness of structures on CDSDS are also investigated. It is concluded that site conditions, ductility level and structural period have important effects on the CDSDS and damping, post-yield stiffness effects are rather complex and of minor importance. The damping, post-yield stiffness effects depend on both the level of ductility and the natural period of structures.  相似文献   

14.
Residual displacements are sensitive to ground motion details, hence more random than peak inelastic displacements. Among the factors with systematic impact on residual displacements, the post‐yield‐stiffness‐ratio has been studied thoroughly; its effects are not investigated further. Concerning another important factor, the hysteresis law, past studies have focused on the bilinear model, which does not represent concrete structures. Residual displacements from nonlinear response‐history analyses of bilinear systems are compared to those from models tuned to concrete structures, conforming to modern codes, deficient or intermediate. Deficient‐type structures, with their narrow, almost self‐centering hysteresis loops, develop markedly smaller residual displacements than those with stable energy‐dissipating behavior. A velocity pulse in the motion increases peak inelastic and residual displacements by about the same proportion. As a fraction of the peak inelastic or spectral displacement, residual displacements are on average almost independent of the period and increase when the lateral strength ratio increases, reaching a limit at a lateral strength ratio of 2 to 5. Peak inelastic displacements are a better basis for estimation of residual displacements than spectral ones: the ratio of the two is almost independent of the period, the lateral strength ratio (beyond values of 2 to 3) and velocity pulses. The spectrum of the ratio of residual displacement to peak inelastic or spectral displacement is considered as a random process of period; its mean and variance functions, marginal probability distributions and autocorrelation functions are given in terms of the lateral strength ratio, the hysteresis model and the presence of a velocity pulse. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
An extensive experimental program of shaking table tests on reduced‐scale structural models was carried out within the activities of the MANSIDE project, for the development of new seismic isolation and energy dissipation devices based on shape memory alloys (SMAs). The aim of the experimental program was to compare the behaviour of structures endowed with innovative SMA‐based devices to the behaviour of conventional structures and of structures endowed with currently used passive control systems. This paper presents a comprehensive overview of the main results of the shaking table tests carried out on the models with and without special braces. Two different types of energy dissipating and re‐centring braces have been considered to enhance the seismic performances of the tested model. They are based on the hysteretic properties of steel elements and on the superelastic properties of SMAs, respectively. The addition of passive control braces in the reinforced concrete frame resulted in significant benefits on the overall seismic behaviour. The seismic intensity producing structural collapse was considerably raised, interstorey drifts and shear forces in columns were drastically reduced. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

16.
The collapse of the Olive View Hospital Psychiatric Day Clinic is studied using three biaxial force-deflection models to represent the columns of the building. These models are: shear collapse, elastic and inelastic. The biaxial models for shear and inelastic behaviour are new developments and are useful for non-linear structural dynamic studies. In the present study, the shear collapse model is intended to represent the actual prototype behaviour. The inelastic model, which is based on a hardening rule of plasticity, is used to study the performance of a hypothetical structure with the same storey shear capacity as the prototype but which exhibits ductile behaviour. The prototype structure had a base storey shear capacity of 25 per cent, and actually failed by shearing of all of the first floor columns. In the present study, the shear collapse model predicted this behaviour even with the El Centro accelerogram as input. This result may have far-reaching significance because many low-rise reinforced concrete buildings which were designed according to recent codes have similar storey shear capacity coefficients and column properties. According to this study, such buildings may collapse even in a moderate earthquake. In the inelastic representation, the structure was found to have a base storey shear capacity of 80 per cent when moment hinging was assumed to occur at the top and bottom of the columns. Even with this high strength capacity, the permanent offset computed from the inelastic model corresponded to a ductility factor of 5 when the Pacoima Dam accelerogram was used as input. On the basis of damage to other structures observed on the site, it seems likely that ground motion of about the Pacoima Dam intensity occurred at Olive View. From this it is concluded that a low-rise ductile frame concrete building, even with this high shear force capacity, may not prove satisfactory for hospital use when subjected to strong ground motion.  相似文献   

17.
Two models of masonry infilled reinforced concrete frame buildings were tested at the shaking table. Models were built in the reduced scale 1:4 using the materials produced in accordance to modelling demands of true replica modelling technique. The first model represented a one‐storey box‐like building and the second one the two‐stories building with plan shaped in the form of a letter H. Models were shaken with the series of horizontal sine dwell motions with gradually increasing amplitude. Masonry infills of tested models were constructed of relatively strong bricks laid in weak mortar. Therefore, typical cracks developed and propagated along mortar beds without cracking of bricks or crushing of infill corners. Data collected from tests will be used in future evaluation, verification and development of computational models for prediction of in‐plane and out‐of‐plane behaviour of masonry infills. The responses of tested models can be well compared with global behaviour of real structures using the modelling rules. The similarity of local behaviour of structural elements, e.g. reinforced concrete joints, is less reliable due to limitations in modelling of steel reinforcement properties. The model responses showed that buildings designed according to Eurocodes are able to sustain relatively high dynamic excitations due to a significant level of structural overstrength. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

18.
In this paper, a contribution of various types of masonry infill to the behaviour of reinforced concrete frames under lateral loads is presented. As a part of the bigger project, ten one‐bay, one‐storey reinforced concrete frames were designed according to the EC8, built in a scale 1:2.5, infilled with masonry and tested under constant vertical and cyclic lateral load. The masonry wall had various strength properties, namely, high strength hollow clay brick blocks, medium strength hollow clay brick blocks and low strength lightweight autoclaved aerated concrete blocks. There were no additional shear connectors between the masonry and frame. The results showed that the composite ‘framed wall’ structure had much higher stiffness, damping and initial strength than the bare frame structure. Masonry infill filled in the load capacity gap from very low (0.05%) to drifts when the frame took over (0.75%). The structures behaved as linear monolithic elements to drifts of 0.1%, reached the maximum lateral capacities at drift of 0.3%, maintained it to drifts of 0.75% and after that their behaviour depended on the frame. Masonry infill had severe damage at drift levels of about 0.75% but contributed to the overall system resistance to drifts of about 1%. At that drift level, the frame had only minor damage and was tested to drifts of about 2% without any loss of capacity. Improvement of the ‘infill provisions’ in the codes could be sought by taking into account the contribution of a common masonry that reduces expected damages by lowering the drift levels. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
耗能梁段作为偏心支撑结构的耗能元件,在大震作用下通过弹塑性变形吸收地震能量,保护主体结构处于弹性受力状态。现行规范基于强度的设计理论,为了保证耗能梁段进入塑性或破坏,梁柱构件需要进行放大内力设计,导致截面过大,而且基于强度的设计方法很难保证结构的整体破坏状态。目前,抗震设计越来越重视基于性能的设计思想,该方法能够评估结构的弹塑性反应。对于高强钢组合偏心支撑,其中耗能梁段和支撑采用Q345钢,框架梁柱采用Q460或者Q690高强度钢材,高强钢不仅带来良好的经济效益,而且能够推广高强钢在抗震设防区的应用。利用基于性能设计方法设计了4种不同形式的高强钢组合偏心支撑钢框架,包括K形、Y形、V形和D形,考虑4层、8层、12层和16层的影响。通过Pushover分析和非线性时程分析评估该结构的抗震性能,研究结果表明:4种形式的高强钢组合偏心支撑钢框架具有类似的抗震性能,在罕遇地震作用下,几乎所有耗能梁段均参与耗能,而且层间侧移与耗能梁段转角沿高度分布较为均匀。其中:D形偏心支撑具有最大的抗侧刚度,但延性较差,而Y形偏心支撑的抗侧刚度最弱,但延性最佳。  相似文献   

20.
In order to mitigate the effect of torsion during earthquakes, most seismic codes of the world provide design guidelines for strength distribution based on the traditional perception that element stiffness and strength are independent parameters. Recent studies have pointed out that for an important class of widely used structural elements such as reinforced concrete flexural walls, stiffness is a strength‐dependent parameter. This implies that the lateral stiffness distribution in a wall‐type system cannot be defined prior to the assignment of elements' strength. Consequently, stiffness eccentricity cannot be computed readily and the current codified torsional provisions cannot be implemented in a straightforward manner. In this study, an alternate guideline for strength distribution among lateral force resisting elements is presented. To develop such a guideline, certain issues related to the dynamic behaviour of asymmetric wall‐type systems during a damaging earthquake were examined. It is shown that both stiffness and strength eccentricity are important parameters affecting the seismic response of asymmetric wall‐type systems. In particular, results indicate that torsional effects can be minimized by using a strength distribution that results in the location of the centre of strength CV and the centre of rigidity CR on the opposite sides of the centre of mass CM. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号