1.
Tests of nine angle-steel concrete column (ASCC) specimens under low cyclic loading are described in a companion paper (Zheng and Ji, 2008). In this paper, the skeleton curves from the numerical simulation are presented, and show good agreement with the test results. Furthermore, parametric studies are conducted to explore the influence of factors such as the axial compression ratio, shear steel plate ratio, steel ratio, prismatic concrete compression strength, yield strength of angle steel and shear span ratio, etc., on the monotonic load-displacement curves of the ASCCs. Based on a statistical analysis of the calculated results, hysteretic models for load-displacement and moment-curvature are proposed, which agree well with the test results. Finally, some suggestions concerning the conformation of ASCCs are proposed, which could be useful in engineering practice.  相似文献   

2.
<正>This paper describes an experimental study of the hysteretic behavior of prestressed truss concrete composite beams(PTCCBs) under cyclic loading.Five beam models were designed and tested,in which the testing parameters include the global reinforcement index β_0,the prestress levelλand the ratio of stirrupρ P_ss in the potential plastic hinge zones.Based on the test results,the failure mode and hysteretic behavior of the tested models are obtained.In addition,the P-△and sectional M- hysteretic models for the PTCCBs at the midspan are established.The P-△hysteretic model shows good agreement with the test results.  相似文献   

3.
The test results described in Part 1 of this paper (Lee and Bruneau, 2008) on twelve steel built-up laced members (BLMs) subjected to quasi-static loading are analyzed to provide better knowledge on their seismic behavior. Strength capacity of the BLM specimens is correlated with the strength predicted by the AISC LRFD Specifications. Assessments of hysteretic properties such as ductility capacity, energy dissipation capacity, and strength degradation after buckling of the specimen are performed. The compressive strength of BLMs is found to be relatively well predicted by the AISC LRFD Specifications. BLMs with smaller kl/r were ductile but failed to reach the target ductility of 3.0 before starting to fracture, while those with larger kl/r could meet the ductility demand in most cases. The normalized energy dissipation ratio, EC/ET and the normalized compressive strength degradation, Cr″/Cr of BLMs typically decrease as normalized displacements δ/δb,exp increase, and the ratios for specimens with larger kl/r dropped more rapidly than for specimens with smaller kl/r; similar trends were observed for the monolithic braces. The BLMs with a smaller slenderness ratio, kl/r, and width-to-thickness ratio, b/t, experienced a larger number of inelastic cycles than those with larger ratios.  相似文献   

4.
In recent earthquakes, a large number of reinforced concrete (RC) bridges were severely damaged due to mixed flexure-shear failure modes of the bridge piers. An integrated experimental and finite element (FE) analysis study is described in this paper to study the seismic performance of the bridge piers that failed in flexure-shear modes. In the first part, a nonlinear cyclic loading test on six RC bridge piers with circular cross sections is carried out experimentally. The damage states, ductility and energy dissipation parameters, stiffness degradation and shear strength of the piers are studied and compared with each other. The experimental results suggest that all the piers exhibit stable flexural response at displacement ductilities up to four before exhibiting brittle shear failure. The ultimate performance of the piers is dominated by shear capacity due to significant shear cracking, and in some cases, rupturing of spiral bars. In the second part, modeling approaches describing the hysteretic behavior of the piers are investigated by using ANSYS software. A set of models with different parameters is selected and evaluated through comparison with experimental results. The influences of the shear retention coefficients between concrete cracks, the Bauschinger effect in longitudinal reinforcement, the bond-slip relationship between the longitudinal reinforcement and the concrete and the concrete failure surface on the simulated hysteretic curves are discussed. Then, a modified analysis model is presented and its accuracy is verified by comparing the simulated results with experimental ones. This research uses models available in commercial FE codes and is intended for researchers and engineers interested in using ANSYS software to predict the hysteretic behavior of reinforced concrete structures.  相似文献   

5.
In this paper, a numerical method for correlation sensitivity analysis of a nonlinear random vibration system is presented. Based on the first passage failure model, the probability perturbation method is employed to determine the statistical characteristics of failure modes and the correlation between them. The sensitivity of correlation between failure modes with respect to random parameters characterizing the uncertainty of the hysteretic loop is discussed. In a numerical example, a two-DOF shear structure with uncertain hysteretic restoring force is considered. The statistical characteristics of response, failure modes and the sensitivity of random hysteretic loop parameters are provided, and also compared with a Monte Carlo simulation.  相似文献   

6.
This paper describes a series of experimental investigations on seventeen specimens of steel reinforced concrete special shaped(SRCSS) columns under low cyclic reversed loading using parallel crosshead equipment. Nine T-shaped SRC columns, four L-shaped SRC columns and four +-shaped SRC columns were tested to examine the effects of shape steel confi guration, loading angle, axial compressive ratio and shear-span ratio on the behavior(strength, stiffness, energy dissipation, ductility, etc.) of SRCSS column specimens. The failure modes and hysteretic performance of all the specimens were obtained in the tests. Test results demonstrate that the shear-span ratio is the main parameter affecting the failure modes of SRCSS columns. The specimens with small shear-span ratio are prone to shear failure, and the primary failure planes in SRCSS columns are parallel to the loading direction. As a result, there is a symmetry between positive and negative loading directions in the hysteretic curves of the SRCSS columns. The majority of displacement ductility coeffi cients for all the specimens are over 3.0, so that the SRCSS columns demonstrate a better deformation capacity. In addition, the equivalent viscous damping coeffi cients of all the specimens are greater than 0.2, indicating that the seismic behavior of SRCSS columns is adequate. Finally, the superposition theory was used to calculate the limits of axial compressive ratio for the specimens, and it is found that the test axial compressive ratio is close to or smaller than the calculated axial compressive ratio limit.  相似文献   

7.
Research on seismic behavior and shear strength of SRHC frame columns   总被引:1,自引:1,他引:0  
The seismic behavior of steel reinforced high strength and high performance concrete(SRHC)frame columns was investigated through pseudo-static experiments of 16 frame columns with various shear span ratios,axial compression ratios,concrete strengths,steel ratios and stirrup ratios.Three kinds of failure mechanisms are presented and the characteristics of experimental hysteretic curves and skeleton curves with different design parameters are discussed.The columns’ductility and energy dissipation were quantitatively evaluated based on seismic resistance.The research results indicate that SRHC frame columns can withstand extreme bearing capacity,but the abilities of ductility and energy dissipation are inferior because of SRHC’s natural brittleness.As a result,the axial load ratio should be restricted and some construction measures adopted,such as increasing the stirrup ratio.This research established effect factors on the bearing capacity of SPHC columns.Finally,an algorithm for obtaining ultimate bearing capacity using the flexural failure mode is established based on a modified planesection assumption.The authors also established equations to determine shearing baroclinic failure and shear bond failure based on the accumulation of the axial load force distribution ratio.The calculated results of shear bearing capacity for different failure modes were in good agreement with the experimental results.  相似文献   

8.
This paper describes a nonlinear finite element (FE) analysis of high strength concrete (HSC) columns, and verifies the results through laboratory experiments. First, a cyclically lateral loading test on nine cantilever column specimens of HSC is described and a numerical simulation is presented to verify the adopted FE models. Next, based on the FE model for specimen No.6, numerical simulations for 70 cases, in which different concrete strengths, stirrup ratios and axial load ratios are considered, are presented to explore the effect of these parameters on the behavior of the HSC columns, and to check the rationality of requirements for these columns specified in the China Code for Seismic Design of Buildings (GB 50011- 2001). In addition, three cases with different stirrup strengths are analyzed to investigate their effect on the behavior of HSC columns. Finally, based on the numerical results some conclusions are presented.  相似文献   

9.
Bonding fiber reinforced polymer (FRP) has been commonly used to improve the seismic behavior of circular reinforced concrete (RC) columns in engineering practice. However, FRP jackets have a significant stress hysteresis effect in this strengthening method, and pre-tensioning the FRP can overcome this problem. This paper presents test results of 25 circular RC columns strengthened with pre-stressed FRP strips under low cyclic loading. The pre-stressing of the FRP strips, types of FRP strips and longitudinal reinforcement, axial load ratio, pre-damage degree and surface treatments of the specimens are considered as the primary factors in the tests. According to the failure modes and hysteresis curves of the specimens, these factors are analyzed to investigate their effect on bearing capacity, ductility, hysteretic behavior, energy dissipation capacity and other important seismic behaviors. The results show that the initial lateral confined stress provided by pre-stressed FRP strips can effectively inhibit the emergence and development of diagonal shear cracks, and change the failure modes of specimens from brittle shear failure to bending or bending-shear failure with better ductility. As a result, the bearing capacity, ductility, energy dissipation capacity and deformation capacity of the strengthened specimens are all significantly improved.  相似文献   

10.
The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing the control effectiveness in mega-frame buildings. In this paper, a dynamic equation and method to assemble parameter matrixes for a mega-sub controlled structure under random wind loads is presented. Semi-active control using magnetorheological dampers for the MSCS under random wind loads is investigated, and is compared with a corresponding system without dampers. A parametric study of the relative stiffness ratio and relative mass ratio between the mega-frame and the substructures, as well as the additional column stiffness ratio that influences the response control effectiveness of the MSCS, is discussed. The studies reveal, for the first time, that different control mechanisms exist. The results indicate that the proposed structure employing semi-active control can offer an effective control mechanism. Guidelines for selecting parameters are provided based on the analytical study.  相似文献   

11.
Tests of nine angle-steel concrete column (ASCC) specimens under low cyclic loading are described in acompanion paper (Zheng and Ji, 2008). In this paper, the skeleton curves from the numerical simulation are presented, andshow good agreement with the test results. Furthermore, parametric studies are conducted to explore the influence of factorssuch as the axial compression ratio, shear steel plate ratio, steel ratio, prismatic concrete compression strength, yield strengthof angle steel and shear span ratio, etc., on the monotonic load-displacement curves of the ASCCs. Based on a statisticalanalysis of the calculated results, hysteretic models for load-displacement and moment-curvature are proposed, which agreewell with the test results. Finally, some suggestions concerning the conformation of ASCCs are proposed, which could beuseful in engineering practice.  相似文献   

12.
钢管高性能混凝土压弯构件滞回性能试验研究   总被引:2,自引:1,他引:2  
考虑钢材强度、混凝土强度、轴压比等参数,进行了18个钢管高性能混凝土试件的试验,分析在往复荷载作用下钢管高性能混凝土荷载-位移关系曲线的特点、构件的轴向变形和抗弯刚度退化情况,并初步探讨往复荷载作用下的钢管高性能混凝土压弯构件承载力。  相似文献   

13.
圆钢管混凝土压弯构件弯矩-曲率滞回模型研究   总被引:3,自引:2,他引:1  
采用数值计算方法,对圆钢管混凝土压弯构件弯矩—曲率滞回关系进行了计算,分析了各参数,如构件轴压比、截面含钢率和材料强度等对圆钢管混凝土压弯构件弯矩—曲率滞回曲线的影响。最后,基于系统参数分析结果提出一种圆钢管混凝土压弯构件弯矩—曲率滞回模型。  相似文献   

14.
To investigate the seismic behavior of I-section columns made of 460 MPa high strength steel(HSS), six specimens were tested under constant axial load and cyclic horizontal load. The specimens were designed with different width-to-thickness ratios and loaded under different axial load ratios. For each specimen, the failure mode was observed and hysteretic curve was measured. Comparison of different specimens on hysteretic characteristic, energy dissipation capacity and deformation capacity were further investigated. Test results showed that the degradation of bearing capacity was due to local buckling of flange and web. Under the same axial load ratio, as width-to-thickness ratio increased, the deformation area of local buckling became smaller. And also, displacement level at both peak load and failure load became smaller. In addition, the full extent of hysteretic curve, energy dissipation capacity, ultimate story drift angle decreased, and capacity degradation occurred more rapidly with the increase of width-to-thickness ratio or axial load ratio. Based on the capacity of story drift angle, limiting values which shall not be exceeded are suggested respectively for flange and web plate of 460 MPa HSS I-section columns when used in SMFs and in IMFs in the case of axial load ratio no more than 0.2. Such values should be smaller when the axial load ratio increases.  相似文献   

15.
圆钢管混凝土压弯构件荷载-位移滞回模型研究   总被引:2,自引:0,他引:2  
本文采用数值计算方法,对圆钢管混凝土压弯构件荷载-位移滞回关系曲线进行了理论分析。理论计算结果与实验结果吻合良好。基于理论模型,分析了各参数,如构件轴压比、长细比、截面含钢率和材料强度等对圆钢管混凝土压弯构件荷载-位移滞回曲线的影响。最终提出-种圆钢管混凝土压弯构件荷载-位移滞回模型及位移延性系数的简化计算方法。  相似文献   

16.
钢管混凝土桥墩抗震性能试验研究   总被引:1,自引:0,他引:1  
臧华  刘钊  李红英  涂永明 《地震学刊》2010,(4):442-446,451
为研究钢管混凝土桥墩的抗震性能,对钢管混凝土桥墩和钢筋混凝土桥墩进行了拟静力对比试验研究。根据试件的破坏发展过程以及各试件的滞回曲线和骨架曲线,分析了其滞回性能、耗能能力、延性、强度退化及刚度退化等抗震性能。试验结果表明,钢管混凝土桥墩的抗震性能明显好于钢筋混凝土桥墩。在含钢率和轴力相同的情况下,钢管混凝土桥墩的滞回曲线比钢筋混凝土桥墩丰满得多,前者的耗能能力约为后者的4.46倍,钢管混凝土桥墩的延性大于钢筋混凝土桥墩;随着轴压比的增大,钢管混凝土桥墩延性有所下降,强度退化加快,但对其刚度退化的影响不大。  相似文献   

17.
目的是解析地预测钢筋混凝土桥墩在反复荷载作用下的非线性滞回特性。使用实验中得到的力一位移滞回曲线,对随轴压比,配筋率和配箍率的变化而变化的刚度和强度折减系数,进行了回归分析,并提出了其表达式。按照提出的理论力一位移滞回模型,能够预测现存钢筋混凝土桥墩的刚度和强度折减情况。  相似文献   

18.
通过2根圆钢管普通混凝土柱与5根圆钢管钢渣混凝土柱在高轴压比下的水平低周反复加载试验,研究圆钢管钢渣混凝土柱的轴压比、钢管壁厚、钢渣砂替代率和长细比对其破坏形态、滞回耗能能力、骨架曲线、延性及耗能、刚度退化的影响规律。研究结果表明:钢渣混凝土试件破坏过程和破坏形态与普通混凝土试件基本相同,主要表现为钢管底部鼓曲的压弯破坏;所有试件滞回曲线饱满,无明显“捏缩”现象;高轴压比试件存在明显承载力突降现象,合理的径厚比(钢管直径/钢管壁厚)对高轴压比试件承载力突降有明显改善作用;低轴压比试件延性系数大于4.0,高轴压比试件延性系数介于1.57~3.76之间,轴压比增大,试件延性下降;试件破坏时等效粘滞阻尼系数ξeq介于0.259~0.437之间;建议采用《钢管混凝土混合结构技术标准》(GB/T51446-2021)或《钢管混凝土结构技术规程》(DBJ/T13-51-2010)计算地震作用下钢管钢渣混凝土柱压弯承载力,但高轴压比钢管钢渣混凝土柱计算结果需乘以折减系数0.8。  相似文献   

19.
新型开孔H型钢阻尼器有限元分析   总被引:2,自引:0,他引:2  
王爽  张春梅  周云 《地震学刊》2012,(3):346-352
设计了分别开椭圆形孔和菱形孔的2种新型H型钢耗能器,阐述了它们的构造与耗能原理。采用有限元软件ABAQUS对开椭圆形孔、菱形孔和条形孔这3种新型耗能器的耗能性能进行数值分析,研究了开孔形状、肢宽与肢高等参数对新型耗能器耗能性能的影响。分析结果表明:新型H型钢耗能器具有饱满的滞回曲线,屈服位移较小、耗能性能稳定,耗能器的屈服位移、初始刚度和等效阻尼比随各肢钢板宽度增大(或高度减小)而增大;在开孔率相近或者肢宽相同的情况下,菱形孔H型钢耗能器的等效阻尼比要比条形孔和椭圆形孔的大,且应力分布更加均匀。  相似文献   