首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Understanding the dynamics and mechanisms of soil water movement and solute transport is essential for accurately estimating recharge rates and evaluating the impacts of agricultural activities on groundwater resources. In a thick vadose zone (0–15 m) under irrigated cropland in the piedmont region of the North China Plain, soil water content, matric potential, and solute concentrations were measured. Based on these data, the dynamics of soil water and solutes were analysed to investigate the mechanisms of soil water and solute transport. The study showed that the 0–15‐m vadose zone can be divided into three layers: an infiltration and evaporation layer (0–2 m), an unsteady infiltration layer (2–6 m), and a quasi‐steady infiltration layer (6–15 m). The chloride, nitrate, and sulphate concentrations all showed greater variations in the upper soil layer (0–1 m) compared to values in the deep vadose zone (below 2 m). The average concentrations of these three anions in the deep vadose zone varied insignificantly with depth and approached values of 125, 242, and 116 mg/L. The accumulated chloride, sulphate, and nitrate were 2,179 ± 113, 1,760 ± 383, and 4,074 ± 421 kg/ha, respectively. The soil water potential and solute concentrations indicated that uniform flow and preferential flow both occurred in the deep vadose zone, and uniform flow was the dominant mechanism of soil water movement in this study. The piston‐like flow velocity of solute transport was 1.14 m per year, and the average value of calculated leached nitrate nitrogen was 107 kg/ha?year below the root zone. The results can be used to better understand recharge processes and improve groundwater resources management.  相似文献   

2.
Magnetic resonance sounding: new method for ground water assessment   总被引:1,自引:0,他引:1  
Lubczynski M  Roy J 《Ground water》2004,42(2):291-309
  相似文献   

3.
1,4‐Dioxane is totally miscible in water, sequestering in vadose pore water that can serve as a source of long‐term groundwater contamination. Although some 1,4‐dioxane is removed by conventional soil vapor extraction (SVE), remediation is typically inefficient. SVE efficiency is hindered by low Henry’s Law constants at ambient temperature and redistribution to vadose pore water if SVE wells pull 1,4‐dioxane vapors across previously clean soil. It was hypothesized that heated air injection and more focused SVE extraction (“Enhanced SVE” or XSVE) could increase the efficiency of 1,4‐dioxane vadose treatment, and this new process was tested at former McClellan Air Force Base, CA. The XSVE system had four peripheral heated air injection wells surrounding a 6.1 m × 6.1 m × 9.1 m deep treatment zone with a central vapor extraction well. After 14 months of operation, soil temperatures reached as high as ~90 °C near the injection wells and the treatment zone was flushed with ~20,000 pore volumes of injected air. Post‐treatment sampling results showed reductions of ~94% in 1,4‐dioxane and ~45% in soil moisture. Given the simplicity of the remediation system components and the promising demonstration test results, XSVE has the potential to be a cost‐effective remediation option for vadose zone soil containing 1,4‐dioxane.  相似文献   

4.
The modeling of thick vadose zones is particularly challenging because of difficulties in collecting a variety of measured sediment properties, which are required for parameterizing the model. Some models rely on synthetic data, whereas others are simplified by running as homogeneous sediment domains and relying on a single set of sediment properties. Few studies have simulated flow processes through a thick vadose zone using real and comprehensive data sets comprising multiple measurements. Here, we develop a flow model for a 7-m-thick vadose zone. This model, combining the numerical codes CTRAN/W with SEEP/W, includes the measured sediment hydraulic properties of the investigated vadose zone and incorporates the actual climate and subsurface conditions of the study site (precipitations, water-table elevations, and stable isotope data). The model is calibrated by fitting the simulated and measured vertical profiles of water content. Our flow model calculates a transit time of 1 year for the travel of water through the 7-m vadose zone; this estimate matches stable isotope-based results obtained previously for this site. A homogeneous sediment domain flow model, which considers only a single set of sediment properties, produces a transit time that is approximately half the duration of that of the heterogeneous flow model. This difference highlights the importance of assuming heterogeneous material within models of thick vadose zones and testifies to the advantage gained when using real sediment hydraulic properties to parametrize a flow model.  相似文献   

5.
Groundwater flows and travel times were analyzed under a landfill site characterized by a thick unsaturated zone, in an arid environment, using two-dimensional models. Transport in the unsaturated zone is important in arid environments with thick vadose zones and usually determines the travel time of groundwater from the landfill site to the regulatory compliance surface. The combined use of a parallel flow (Dupuit-Forchheimer) areal model and vertical cross-sectional model is explored at a site typical in the utility industry. Flow paths and travel times to the compliance zone are obtained for use in landfill site design or environmental impact assessments. Sensitivity analysis shows that boundary conditions are important factors influencing the entire analysis and thus need to be confirmed with field measurements.  相似文献   

6.
The vadose zone is the main region controlling water movement from the land surface to the aquifer and has a very complex structure. The use of non-invasive or minimally invasive geophysical methods especially electrical resistivity imaging is a cost-effective approach adapted for long-term monitoring of the vadose zone. The main aim of this work is to know the fractures in the vadose zone, of granitic terrene, through which the recharge or preferred path recharge to the aquifer takes place and thus to relate moisture and electrical resistivity. Time lapse electrical resistivity tomography (TLERT) experiment was carried out in the vadose zone of granitic terrene at the Indian Geophysical Research Institute, Hyderabad along two profiles to a depth of 18 m and 13 m each. The profiles are 300 m apart. Piezometric, rainfall and soil moisture data were recorded to correlate with changes in the rainfall recharge. These TLERT difference images showed that the conductivity distribution was consistent with the recharge occurring along the minor fractures. We mapped the fractures in hard rock or granites to see the effect of the recharge on resistivity variation and estimation of moisture content. These fractures act as the preferred pathways for the recharge to take place. A good correlation between the soil moisture and resistivity is established in the vadose zone of granitic aquifer. Since the vadose zone exhibits extremely high variability, both in space and time, the surface geophysical investigations such as TLERT have been a simple and useful method to characterize the vadose zone, which would not have been possible with the point measurements alone. The analyses of the pseudosection with time indicate clearly that the assumption of the piston flow of the moisture front is not valid in hard rocks. The outcome of this study may provide some indirect parameters to the well known Richard's equation in studying the unsaturated zone.  相似文献   

7.
The measured drainage fluxes through a layered volcanic vadose zone exhibited high spatial variability as a consequence of heterogeneous flow conditions. The drainage flux variability was quantified using automated equilibrium tension lysimeters, installed in close‐proximity and resulted in high variability in the Br masses recovered from a conservative tracer experiment. The primary cause of the heterogeneous flow was attributed to textural changes occurring at the interface between volcanic layers, resulting in development of funnel‐flow patterns, and further enhanced by the existence of hydrophobic conditions. The Br recoveries in individual automated equilibrium tension lysimeters were used to determine the corresponding variable sizes of the surface areas contributing drainage to the lysimeters. The tracer experiment confirmed the existence of unsaturated lateral transport occurring at the sloping interface of the coarse Taupo Ignimbrite material with the silty Palaeosol layer at approximately 4.2 m depth. This study demonstrates that measurements of both flux and solute concentrations at multiple locations are essential when heterogeneous flow is suspected to be present, to be able to determine reliable estimates of contaminant leaching through the vadose zone at the plot scale. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
Five years of hydrogeological monitoring and field activities performed in the complex hydrogeological system of the Acque Albule basin (AAB) were conducted to define the hydrogeological setting, the relationship between deep and shallow aquifers and a conceptual groundwater flow model of this exploited area using conventional quantitative techniques. The basin, which is located close to Rome (Italy) on the west side of the Apennine chain and just north of the Colli Albani volcano, subsided after development of a north–south fault system (about 115 000 y bp). The AAB experiences intense hydrothermal activity, which has produced a large travertine deposit (80‐m thick). The travertine deposit constitutes a fractured aquifer that is the final destination of more than 5 m3 s‐1 of water and is strongly dewatered by quarry activities. The complex hydrogeology of this basin was investigated, revealing two main hydraulically connected aquifers, one thermalised and partly confined into the limestone bedrock and one unconfined in the travertine. The two aquifers are separated by a non‐continuous clayey aquiclude. The hydrogeological survey and geological characterisation contributed to the development of the groundwater flow conceptual model. Analysis and comparison of the monitored levels highlighted the pattern of flow between the deep and shallow parts of the flow system. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Natural source zone depletion (NSZD) refers to processes within chemically impacted vadose and saturated zones that reduce the mass of contaminants remaining in a defined source control volume. Studies of large petroleum hydrocarbon release sites have shown that the depletion rate by vapor phase migration of degradation products from the source control volume through the vadose zone (V‐NSZD) is often considerably higher than the rate of depletion from the source control volume by groundwater flow carrying dissolved petroleum hydrocarbons arising from dissolution, desorption, or back diffusion, and degradation products arising from biodegradation (GW‐NSZD). In this study, we quantified vadose zone and GW‐NSZD at a small unpaved fuel release site in California typical of those in settings with predominantly low permeability media. We estimated vadose zone using a dense network of efflux monitoring locations at four sampling events over 2 years, and GW‐NSZD using groundwater monitoring data downgradient of the source control volume in three depth intervals spanning up to 9 years. On average, vadose zone was 17 times greater than GW‐NSZD during the time interval of comparison, and vadose zone was in the range of rates quantified at other sites with petroleum hydrocarbon releases. Estimating vadose zone and GW‐NSZD rates is challenging but the vadose zone rate is the best indicator of overall source mass depletion, whereas GW‐NSZD rates may be useful as baselines to quantify progress of natural or engineered remediation in portions of the saturated zone in which there are impediments to loss of methane and other gases to the vadose zone.  相似文献   

10.
A thorough understanding of rainfall recharge processes and their controlling factors is essential for management of groundwater systems. This study investigates the effects of various meteorological and hydrogeological factors on the gross recharge percentages, the rainfall–recharge relationships and the recharge threshold values for unconfined sandy aquifers under an equatorial climate. Among the meteorological factors investigated, rainfall intensity was found to have the most significant impact on the gross recharge rate. The effects of potential evaporation rate, relative humidity and air temperature on the gross recharge percentage were significant when the vadose zone thickness is larger than 2·5 m. The recharge threshold values were found to depend strongly on the vadose zone thickness. The rainfall–recharge relationships could generally be well defined by a normal–log relationship. The rainfall–recharge relationships derived here are applicable to yield estimates of gross recharge percentages for unconfined sandy aquifers under an equatorial climate, using rainfall intensity and vadose zone thickness as input variables. In this study, a theory was developed and validated to provide physical explanations for the observations, based on the residence time of the percolated rainwater within the vadose zone. Among the soil hydraulic parameters tested, porosity and saturated hydraulic conductivity were found to have the most pronounced effects on the gross recharge percentage. Utilizing the sensitivity results and the theory derived, an approach was developed for extending the application of the derived rainfall–recharge relationships to other sand textures. The approach was found to be capable of producing rough and fast estimations of gross recharge percentage for other sand textures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
A thin layer of fine‐grained sediment commonly is deposited at the sediment–water interface of streams and rivers during low‐flow conditions, and may hinder exchange at the sediment–water interface similar to that observed at many riverbank‐filtration (RBF) sites. Results from a numerical groundwater‐flow model indicate that a low‐permeability veneer reduces the contribution of river water to a pumping well in a riparian aquifer to various degrees, depending on simulated hydraulic gradients, hydrogeological properties, and pumping conditions. Seepage of river water is reduced by 5–10% when a 2‐cm thick, low‐permeability veneer is present on the bed surface. Increasing thickness of the low‐permeability layer to 0·1 m has little effect on distribution of seepage or percentage contribution from the river to the pumping well. A three‐orders‐of‐magnitude reduction in hydraulic conductivity of the veneer is required to reduce seepage from the river to the extent typically associated with clogging at RBF sites. This degree of reduction is much larger than field‐measured values that were on the order of a factor of 20–25. Over 90% of seepage occurs within 12 m of the shoreline closest to the pumping well for most simulations. Virtually no seepage occurs through the thalweg near the shoreline opposite the pumping well, although no low‐permeability sediment was simulated for the thalweg. These results are relevant to natural settings that favour formation of a substantial, low‐permeability sediment veneer, as well as central‐pivot irrigation systems, and municipal water supplies where river seepage is induced via pumping wells. Published in 2011 by John Wiley & Sons, Ltd.  相似文献   

12.
The fate and transport of contaminants in the vicinity of septic fields remains poorly understood in many hydrogeomorphological environments. We report hydrometric data from an intensive hillslope‐scale experiment conducted between 29 August and 11 November 1998 at a residential leach field in New York State. The objective of our study was to characterize water flux within the vadose zone, understand the physical controls on the flux, and predict how this ultimately will affect subsurface water quality. Soil‐water flux was calculated using matric potential measurements from a network of 25 tensiometer nests, each nest consisting of three tensiometers installed to depths of 10, 50 and 130 cm. Unsaturated hydraulic conductivity curves were derived at each depth from field‐determined time‐domain reflectometry–tensiometry moisture‐release curves and borehole permeametry measurements. Flownets indicated that a strong upward flux of soil water occurred between rainstorms. Following the onset of (typically convective) rainfall, low near‐surface matric potentials were rapidly converted to near‐saturated and saturated conditions, promoting steep vertical gradients through the near‐surface horizons of the hillslope. Lateral hydraulic gradients were typically 10 times smaller than the vertical gradients. Resultant flow vectors showed that the flux was predominantly vertical through the vadose zone, and that the flux response to precipitation was short‐lived. The flux response was controlled primarily by the shape of the unsaturated hydraulic conductivity curves, which indicated a rapid loss of conductivity below saturation. Thus, soil water had a very high residence time in the vadose zone. The absence of rapid wetting at 130 cm and the delayed and small phreatic zone response to rainfall indicated that water movement through macropores did not occur on this hillslope. These results are consistent with a Cl tracing experiment, which demonstrated that the tracer was retained in the vadose zone for several months after injection to the system. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

13.
Soil vapor extraction (SVE) is a prevalent remediation remedy for volatile organic compound (VOC) contaminants in the vadose zone. To support selection of an appropriate condition at which SVE may be terminated for site closure or for transition to another remedy, an evaluation is needed to determine whether vadose zone VOC contamination has been diminished sufficiently to keep groundwater concentrations below threshold values. A conceptual model for this evaluation was developed for VOC fate and transport from a vadose zone source to groundwater when vapor‐phase diffusive transport is the dominant transport process. A numerical analysis showed that, for these conditions, the groundwater concentration is controlled by a limited set of parameters, including site‐specific dimensions, vadose zone properties, and source characteristics. On the basis of these findings, a procedure was then developed for estimating groundwater concentrations using results from the three‐dimensional multiphase transport simulations for a matrix of parameter value combinations and covering a range of potential site conditions. Interpolation and scaling processes are applied to estimate groundwater concentrations at compliance (monitoring) wells for specific site conditions of interest using the data from the simulation results. The interpolation and scaling methodology using these simulation results provides a far less computationally intensive alternative to site‐specific three‐dimensional multiphase site modeling, while still allowing for parameter sensitivity and uncertainty analyses. With iterative application, the approach can be used to consider the effect of a diminishing vadose zone source over time on future groundwater concentrations. This novel approach and related simulation results have been incorporated into a user‐friendly Microsoft® Excel®‐based spreadsheet tool entitled SVEET (Soil Vapor Extraction Endstate Tool), which has been made available to the public.  相似文献   

14.
Atomic weapons testing at the Nevada Test Site has introduced many tracers for quantifying subsurface hydrologic transport processes in arid climates. In 1975, groundwater adjacent to the Cambric test, conducted beneath Frenchman Flat 10 years earlier, was pumped steadily for 16 years to elicit information on the migration of residual radioactivity through the saturated zone. Radionuclides in the pumping well effluent, including tritium, 14C, 36Cl, and 85Kr, were extensively monitored prior to its discharge in an unlined ditch, where approximately a third of the flow infiltrated over a distance of 1 km. Radionuclide infiltration through a 220-m thick vadose zone created a second, and rather unique long-term field experiment. Effluent data have been utilized in conjunction with geologic data, new radionuclide measurements, isotopic age-dating estimates, and vadose zone flow and transport models to better understand the movement of radionuclides between the ditch, the water table and a nearby groundwater monitoring well. Detection of tritium in the monitoring well occurred approximately 16 years after its initial discharge into the ditch. Modeling and tritium age dating have suggested 3–5 years of this 16-year transit time occurred solely in the vadose zone. They also suggest considerable recirculation of the pumping well discharge back into the original pumping well. Notably, there have been no observations of 14C or 85Kr in the monitoring well, suggesting their preferential retention or volatilization during transit to the water table.  相似文献   

15.
Seasonal signals of stable isotopes in precipitation, combined with measurements of isotope ratios in soil water, can be used for quantitative estimation of groundwater recharge rates. This study investigates the applicability of using the piston flow principle and the peak shift displacement method to estimate actual groundwater recharge rates in a humid Nordic region located in the province of Quebec, Canada. Two different sites with and without vegetation (C1 and C2) in an unconfined aquifer were tested by measuring soil water isotope ratios (18O/16O and 2H/1H) and volumetric pore water content. Core samples were obtained along the vadose zone down to the groundwater table at the two sites (2.45 m for Site C1 and 4.15 m for Site C2). The peak shift method to estimate groundwater recharge rates was shown to be accurate only in certain specific conditions inherent to the soil properties and the topographical situation of the investigated sites. Indeed, at Site C2, recharge from the snowmelt could not be estimated because of heterogeneity in the lower part of the vadose zone. At this same site the later recharge after the snowmelt (in the period from late spring to early autumn) could be estimated accurately because the upper part of the vadose zone was homogeneous. Furthermore, at site C1, runoff/runon phenomena hampered calculations of actual infiltration and thus produced inaccurate results for recharge. These two different site effects (heterogeneity in the first site and runoff/runon in the other site) were identified as being limiting factors in the accurate assessment of actual recharge. This study therefore recommends the use of the peak shift method for (1) humid Nordic regions, (2) homogeneous and thick vadose zones, and (3) areas with few or limited site effects (runoff/runon).  相似文献   

16.
Disease outbreaks associated with drinking water drawn from untreated groundwater sources represent a substantial proportion (30.3%) of the 818 drinking water outbreaks reported to CDC's Waterborne Disease and Outbreak Surveillance System (WBDOSS) during 1971 to 2008. The objectives of this study were to identify underlying contributing factors, suggest improvements for data collection during outbreaks, and inform outbreak prevention efforts. Two researchers independently reviewed all qualifying outbreak reports (1971 to 2008), assigned contributing factors and abstracted additional information (e.g., cases, etiology, and water system attributes). The 248 outbreaks resulted in at least 23,478 cases of illness, 390 hospitalizations, and 13 deaths. The majority of outbreaks had an unidentified etiology (n = 135, 54.4%). When identified, the primary etiologies were hepatitis A virus (n = 21, 8.5%), Shigella spp. (n = 20, 8.1%), and Giardia intestinalis (n = 14, 5.7%). Among the 172 (69.4%) outbreaks with contributing factor data available, the leading contamination sources included human sewage (n = 57, 33.1%), animal contamination (n = 16, 9.3%), and contamination entering via the distribution system (n = 12, 7.0%). Groundwater contamination was most often facilitated by improper design, maintenance or location of the water source or nearby waste water disposal system (i.e., septic tank; n = 116, 67.4%). Other contributing factors included rapid pathogen transport through hydrogeologic formations (e.g., karst limestone; n = 45, 26.2%) and preceding heavy rainfall or flooding (n = 36, 20.9%). This analysis underscores the importance of identifying untreated groundwater system vulnerabilities through frequent inspection and routine maintenance, as recommended by protective regulations such as Environmental Protection Agency's (EPA's) Groundwater Rule, and the need for special consideration of the local hydrogeology.  相似文献   

17.
Light non-aqueous phase liquids (LNAPL) represent one of the most serious problems in aquifers contaminated with petroleum hydrocarbons liquids. To design an appropriate remediation strategy it is essential to understand the behavior of the plume. The aim of this paper is threefold: (1) to characterize the fluid distribution of an LNAPL plume detected in a volcanic low-conductivity aquifer (∼0.4 m/day from slug tests interpretation), (2) to simulate the recovery processes of the free-product contamination and (3) to evaluate the primary recovery efficiency of the following alternatives: skimming, dual-phase extraction, Bioslurping and multi-phase extraction wells. The API/Charbeneau analytical model was used to investigate the recovery feasibility based on the geological properties and hydrogeological conditions with a multi-phase (water, air, LNAPL) transport approach in the vadose zone. The modeling performed in this research, in terms of LNAPL distribution in the subsurface, show that oil saturation is 7% in the air–oil interface, with a maximum value of 70% in the capillary fringe. Equilibrium between water and LNAPL phases is reached at a depth of 1.80 m from the air–oil interface. On the other hand, the LNAPL recovery model results suggest a remarkable enhancement of the free-product recovery when simultaneous extra-phase extraction was simulated from wells, in addition to the LNAPL lens. Recovery efficiencies were 27%, 65%, 66% and 67% for skimming, dual-phase extraction, Bioslurping and multi-phase extraction, respectively. During a 3-year simulation, skimmer wells and multi-phase extraction showed the lowest and highest LNAPL recovery rates, with expected values from 207 to 163 and 2305 to 707 l-LNAPL/day, respectively. At a field level we are proposing a well distribution arrangement that alternates pairs of dual-phase well-Bioslurping well. This not only improves the recovery of the free-product plume, but also pumps the dissolve plume and enhances in situ biodegradation in the vadose zone. Thus, aquifer and soil remediation can be achieved at a shorter time. Rough calculations suggest that LNAPL can be recovered at an approximate cost of $6–$10/l.  相似文献   

18.
Effective long‐term operation of soil vapor extraction (SVE) systems for cleanup of vadose‐zone sources requires consideration of the likelihood that remediation activities over time will alter the subsurface distribution and configuration of contaminants. A method is demonstrated for locating and characterizing the distribution and nature of persistent volatile organic contaminant (VOC) sources in the vadose zone. The method consists of three components: analysis of existing site and SVE‐operations data, vapor‐phase cyclic contaminant mass‐discharge testing, and short‐term vapor‐phase contaminant mass‐discharge tests conducted in series at multiple locations. Results obtained from the method were used to characterize overall source zone mass‐transfer limitations, source‐strength reductions, potential changes in source‐zone architecture, and the spatial variability and extent of the persistent source(s) for the Department of Energy's Hanford site. The results confirmed a heterogeneous distribution of contaminant mass discharge throughout the vadose zone. Analyses of the mass‐discharge profiles indicate that the remaining contaminant source is coincident with a lower‐permeability unit at the site. Such measurements of source strength and size as obtained herein are needed to determine the impacts of vadose‐zone sources on groundwater contamination and vapor intrusion, and can support evaluation and optimization of the performance of SVE operations.  相似文献   

19.
Although most recharge estimation studies apply multiple methods to identify the possible range in recharge values, many do not distinguish clearly enough between inherent uncertainty of the methods and other factors affecting the results. We investigated the additional value that can be gained from multi-method recharge studies through insights into hydrogeological understanding, in addition to characterizing uncertainty. Nine separate groundwater recharge estimation methods, with a total of 17 variations, were applied at a shallow aquifer in northwest Ethiopia in the context of the potential for shallow groundwater resource development. These gave a wide range of recharge values from 45 to 814 mm/a. Critical assessment indicated that the results depended on what the recharge represents (actual, potential, minimum recharge or change in aquifer storage), and spatial and temporal scales, as well as uncertainties from application of each method. Important insights into the hydrogeological system were gained from this detailed analysis, which also confirmed that the range of values for actual recharge was reduced to around 280-430 mm/a. This study demonstrates that even when assumptions behind methods are violated, as they often are to some degree especially when data are limited, valuable insights into the hydrogeological system can be gained from application of multiple methods.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号