首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
In this study, Re and Os isotopes were systematically determined in six geological reference materials (RMs; covering a wide range of lithologies) using the Carius tube (CT) digestion technique with and without hydrofluoric acid desilicification. Our results show that the HF desilicification increased the Re extraction efficiency (by 9–15%) evidenced from basaltic and andesitic rocks (e.g., BHVO‐2, TDB‐1 and AGV‐2). This implies that a small proportion of Re resides in silicate phases. For mafic–ultramafic rocks (e.g., BCR‐2, WGB‐1 and WPR‐1), Re extraction efficiencies obtained by the CT digestion with and without HF desilicification were similar. This may indicate that Re in these rocks may dominantly reside in some phases (e.g., magnetite and sulfides) that could be completely dissolved in aqua regia solutions without the aid of HF desilicification. Our results also show that the HF desilicification increased Os extraction efficiency (by 13–99%) in some RMs (e.g., BHVO‐2, WGB‐1 and AGV‐2). This observation suggests that a portion of Os‐rich trace phases may occur as inclusions in the silicate phases that act as isolators at ~ 200 mesh sizes. This study demonstrates that the HF desilicification step prior to CT digestion is important for complete extraction of Re and Os in geological samples.  相似文献   

2.
The demand for large and reliable data sets on isotopic composition has increased in geochemistry and environmental sciences over recent years. We present an automated ion chromatographic separation method using a robotic pipetting arm, termed ‘ChemCobOne’, to reduce sample separation time. Its performance was tested for lithium isotope separation in geological reference materials using a single‐step separation with HCl (0.2 mol l?1) and a 2 ml resin volume. This refined lithium purification method does not forfeit precision, accuracy or purity compared with manual sample processing. In addition, a δ7Li value for NASS‐6 of 30.99 ± 0.50‰ (2s) (95% CI = 0.14‰, n = 44) was determined and the first δ7Li values for the granite rock reference material GS‐N (?0.57 ± 0.25‰ (2s), 95% CI = 0.15‰, n = 15), and for the soil reference material NIST SRM 2709a (?0.37 ± 0.67‰ (2s), 95% CI = 0.15‰, n = 63) are proposed.  相似文献   

3.
The Lamont‐Doherty Earth Observatory radiogenic isotope group has been systematically measuring Sr‐Nd‐Pb‐Hf isotopes of USGS reference material BCR‐2 (Columbia River Basalt 2), as a chemical processing and instrumental quality control monitor for isotopic measurements. BCR‐2 is now a widely used geochemical inter‐laboratory reference material (RM), with its predecessor BCR‐1 no longer available. Recognising that precise and accurate data on RMs is important for ensuring analytical quality and for comparing data between different laboratories, we present a compilation of multiple digestions and analyses made on BCR‐2 during the first author's dissertation research. The best estimates of Sr, Nd and Hf isotope ratios and measurement reproducibilities, after filtering at the 2s level for outliers, were 87Sr/86Sr = 0.705000 ± 11 (2s, 16 ppm, n = 21, sixteen digestions, one outlier), 143Nd/144Nd = 0.512637 ± 13 (2s, 25 ppm, n = 27, thirteen digestions, one outlier) and 176Hf/177Hf = 0.282866 ± 11 (2s, 39 ppm, n = 25, thirteen digestions, no outliers). Mean Nd and Hf values were within error of those reported by Weis et al. (2006, 2007) in their studies of RMs; mean Sr values were just outside the 2s uncertainty range of both laboratories. Moreover, a survey of published Sr‐Nd‐Hf data shows that our results fall within the range of reported values, but with a smaller variability. Our Pb isotope results on acid leached BCR‐2 aliquots (n = 26, twelve digestions, two outliers) were 206Pb/204Pb = 18.8029 ± 10 (2s, 55 ppm), 207Pb/204Pb = 15.6239 ± 8 (2s, 52 ppm), 208Pb/204Pb = 38.8287 ± 25 (2s, 63 ppm). We confirm that unleached BCR‐2 powder is contaminated with Pb, and that sufficient leaching prior to digestion is required to achieve accurate values for the uncontaminated Pb isotopic compositions.  相似文献   

4.
This study presents a high‐precision method to measure barium (Ba) isotope compositions of international carbonate reference materials and natural carbonates. Barium was purified using chromatographic columns filled with cation exchange resin (AG50W‐X12, 200–400 mesh). Barium isotopes were measured by MC‐ICP‐MS, using a 135Ba–136Ba double‐spike to correct mass‐dependent fractionation during purification and instrumental measurement. The precision and accuracy were monitored by measuring Ba isotope compositions of the reference material JCp‐1 (coral) and a synthetic solution obtained by mixing NIST SRM 3104a with other matrix elements. The mean δ137/134Ba values of JCp‐1 and the synthetic solution relative to NIST SRM 3104a were 0.21 ± 0.03‰ (2s,= 16) and 0.02 ± 0.03‰ (2s,= 6), respectively. Replicate measurements of NIST SRM 915b, COQ‐1, natural coral and stalagmite samples gave average δ137/134Ba values of 0.10 ± 0.04‰ (2s,= 18), 0.08 ± 0.04‰ (2s,= 20), 0.27 ± 0.04‰ (2s,= 16) and 0.04 ± 0.03‰ (2s,= 20), respectively. Barium mass fractions and Ba isotopes of subsamples drilled from one stalagmite profile were also measured. Although Ba mass fractions varied significantly along the profile, Ba isotope signatures were homogeneous, indicating that Ba isotope compositions of stalagmites could be a potential tool (in addition to Ba mass fractions) to constrain the source of Ba in carbonate rocks and minerals.  相似文献   

5.
Properly combining highly siderophile element (HSE: Re, Pd, Pt, Ru, Ir, Os) abundance data, obtained by isotope dilution, with corresponding 187Os/188Os and 186Os/188Os measurements of rocks requires efficient digestion of finely‐ground powders and complete spike‐sample equilibration. Yet, because of the nature of commonly used methods for separating Os from a rock matrix, hydrofluoric acid (HF) is typically not used in such digestions. Consequently, some silicates are not completely dissolved, and HSE residing within these silicates may not be fully accessed. Consistent with this, some recent studies of basaltic reference materials (RMs) have concluded that an HF‐desilicification procedure is required to fully access the HSE (Ishikawa et al. (2014) Chemical Geology, 384, 27–46; Li et al. (2015) Geostandards and Geoanalytical Research, 39, 17–30). Highly siderophile element abundance and Os isotope studies of intraplate basalts typically target samples with a range of MgO contents (< 8 to > 18% m/m, or as mass fractions, < 8 to > 18 g per 100 g), in contrast to the lower MgO mass fractions (< 10 g per 100 g) of basalt and diabase RMs (i.e., BIR‐1, BHVO‐2, TDB‐1). To investigate the effect of HF‐desilicification on intraplate basalts, experiments were performed on finely ground Azores basalts (8.1–17 g per 100 g MgO) using a ‘standard acid digestion’ (2:1 mixture of concentrated HNO3 and HCl), and a standard acid digestion, followed by HF‐desilicification. No systematic trends in HSE abundances were observed between data obtained by standard acid digestion and HF‐desilicification. Desilicification procedures using HF do not improve liberation of the HSE from Azores basalts, or some RMs (e.g., WPR‐1). We conclude that HF‐desilicification procedures are useful for obtaining total HSE contents of some young lavas, but this type of procedure is not recommended for studies where Re‐Pt‐Os chronological information is desired. The collateral effect of a standard acid digestion to liberate Os, followed by HF‐desilicification to obtain Re and Pt abundances in samples, is that the measured Re/Os and Pt/Os may not correspond with measured 187Os/188Os or 186Os/188Os.  相似文献   

6.
Geological reference materials (RMs) with variable compositions and NIST SRM 612 were analysed by isotope dilution mass spectrometry for bulk rock concentrations of chalcogen elements (sulfur, selenium and tellurium), rhenium and platinum‐group elements (PGEs: Ru, Pd, Os, Ir and Pt), including the isotope amount ratios of 187Os/188Os. All concentrations were obtained from the same aliquot after HCl‐HNO3 digestion in a high pressure asher at 320 °C. Concentrations were determined after chemical separation by negative TIMS, ICP‐MS and hydride generation ICP‐MS (Se, Te). As in previous studies, concentrations of the PGEs in most RMs were found to be highly variable, which may be ascribed to sample heterogeneity at the < 1 g level. In contrast, S, Se and Te displayed good precision (RSD < 5%) in most RMs, suggesting that part of the PGE budget is controlled by different phases, compared with the chalcogen budget. The method may minimise losses of volatile chalcogens during the closed‐system digestion and indicates the different extent of heterogeneity of chalcogens, Re and PGEs in the same sample aliquot. OKUM, SCo‐1, MRG‐1, DR‐N and MAG‐1 are useful RMs for the chalcogens. NIST SRM 612 displays homogenous distribution of S, Se, Te, Pt and Pd in 30 mg aliquots, in contrast with micro‐scale heterogeneity of Se, Pd and Pt.  相似文献   

7.
The traditional Carius tube technique is cumbersome and requires skilful work to seal the Carius tube, which can be used only once. We describe a modification to the technique that does not require the use of a high‐temperature welding torch to melt the Carius tube to seal it. The newly designed Carius tube consists of a main body with a 3 mm‐thick glass wall, a neck and head with walls 4 mm in thickness, and an efficient screw‐thread stopper. These new features allowed the tube to be used repeatedly. We demonstrate relatively low procedural blanks derived for Re and Os, and platinum‐group elements (PGEs), using the redesigned tube. A temperature of 220 °C could be reached for about 5 ml of HNO3 for a 47 ml tube and for 32 ml of inverse aqua regia for a 200 ml tube. This digestion technique can be used for routine analysis of Re and PGEs in geological samples.  相似文献   

8.
In this study the homogeneity of the zinc isotopic composition in the NIST SRM 683 reference material was examined by measuring the Zn isotopic signature in microdrilled sample powders from two metal nuggets. Zinc was purified using AG MP‐1M resin and then measured by MC‐ICP‐MS. Instrumental mass bias was corrected using the “sample‐standard bracketing” method and empirical external normalisation with Cu doping. After evaluating the potential effects of varying acid mass fractions and different matrices, high‐precision Zn isotope data were obtained with an intermediate measurement precision better than ± 0.05‰ (δ66Zn, 2s) over a period of 5 months. The δ66ZnJMC‐Lyon mean values of eighty‐four and fourteen drilled powders from two nuggets were 0.11 ± 0.02‰ and 0.12 ± 0.02‰, respectively, indicating that NIST SRM 683 is a good isotopic reference material with homogeneous Zn isotopes. The Zn isotopic compositions of seventeen rock reference materials were also determined, and their δ66Zn values were in agreement with most previously published data within 2s. The δ66Zn values of most of the rock reference materials analysed were in the range 0.22–0.36‰, except for GSP‐2 (1.07 ± 0.06‰, n = 12), NOD‐A‐1 (0.96 ± 0.03‰, = 6) and NOD‐P‐1 (0.78 ± 0.03‰, = 6). These comprehensive data should serve as reference values for quality assurance and interlaboratory calibration exercises.  相似文献   

9.
Sulfur isotope measurements in three sulfide (two pyrite and one pyrrhotite) samples on two epoxy mounts showed that the mount‐to‐mount variation of raw δ34S values was negligible when secondary ion mass spectrometry (SIMS) analytical settings remained stable. In consequence, an off‐mount calibration procedure for SIMS sulfur isotope analysis was applied in this study. YP136 is a pyrrhotite sample collected from northern Finland. Examination of thin sections with a polarising microscope, backscattered electron image analyses and wavelength dispersive spectrometry mapping showed that the sample grains display no internal growth or other zoning. A total of 318 sulfur isotope (spot) measurements conducted on more than 100 randomly selected grains yielded highly consistent sulfur isotope ratios. The repeatability of all the analytical results of 34S/32S was 0.3‰ (2s,= 318), which is the same as that of the well‐characterised pyrite reference materials PPP‐1 and UWPy‐1. Its δ34S value determined by gas mass spectrometry was 1.5 ± 0.1‰ (2s,= 11), which agrees with the SIMS data (1.5 ± 0.3‰, 2s) calibrated by pyrrhotite reference material Po‐10. Therefore, YP136 pyrrhotite is considered a candidate reference material for in situ sulfur isotope determination.  相似文献   

10.
We have developed a new sequential extraction technique that does not require complex procedures and is efficient in determining metal and semimetal contents of carbon‐rich rocks. Six geological reference materials (SBC‐1, SCHS‐1, SCo‐1, SDO‐1, SGR‐1b and SLg‐1) and an in‐house black shale (SH‐1) were selected to test the method, which consists of four main digestion steps involving: (a) dilute HCl acid; (b) NaOH; (c) aqua regia; and (d) hydrofluoric acid. Compared with traditional aqua regia + hydrofluoric acid attack, this new protocol recovers more of the moderately volatile elements during early extraction of humic substances. In addition when compared with reference values, those for most elements are in agreement within uncertainty. Furthermore, this new protocol reveals important information on the partitioning of elements; for instance, steps one and two indicate which elements are associated with carbonates and organic phases from fulvic and humic acid extractions, whereas step three provides results for which elements are associated with sulfide minerals and step four indicates which elements remained in the silicate and oxide phases.  相似文献   

11.
A new natural zircon reference material SA01 is introduced for U‐Pb geochronology as well as O and Hf isotope geochemistry by microbeam techniques. The zircon megacryst is homogeneous with respect to U‐Pb, O and Hf isotopes based on a large number of measurements by laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and secondary ion mass spectrometry (SIMS). Chemical abrasion isotope dilution thermal ionisation mass spectrometry (CA‐ID‐TIMS) U‐Pb isotopic analyses produced a mean 206Pb/238U age of 535.08 ± 0.32 Ma (2s, n = 10). Results of SIMS and LA‐ICP‐MS analyses on individual shards are consistent with the TIMS ages within uncertainty. The δ18O value determined by laser fluorination is 6.16 ± 0.26‰ (2s, n = 14), and the mean 176Hf/177Hf ratio determined by solution MC‐ICP‐MS is 0.282293 ± 0.000007 (2s, n = 30), which are in good agreement with the statistical mean of microbeam analyses. The megacryst is characterised by significant localised variations in Th/U ratio (0.328–4.269) and Li isotopic ratio (?5.5 to +7.9‰); the latter makes it unsuitable as a lithium isotope reference material.  相似文献   

12.
In this study, the USGS black shale reference material SBC‐1 was investigated as a matrix‐matched reference material for both intra‐laboratory calibration and inter‐laboratory comparison of high‐precision Re‐Os dating for organic‐rich sedimentary rocks. This reference material was analysed for Re‐Os isotopic composition by three digestion protocols – inverse aqua regia, CrO3‐H2SO4 and H2O2‐HNO3. The results for SBC‐1 obtained by inverse aqua regia digestion yielded similar Re mass fractions but slightly (~ 5%) higher Os mass fractions and lower 187Os/188Os values than the CrO3‐H2SO4 and H2O2‐HNO3 digestions. The data set of inverse aqua regia digestion exhibited strong correlations in plots of 187Os/188Os vs. 1/192Os and 187Os/188Os vs. 187Re/188Os, which may signify the incorporation of detrital Re and Os into organic matter in the Re‐Os system. Similar correlations were also observed for the CrO3‐H2SO4 digestion data set, but not for that of H2O2‐HNO3. The data indicate that there is an amount of non‐hydrogenous Os in SBC‐1 and that CrO3‐H2SO4 and H2O2‐HNO3 digestions would minimise liberation of the non‐hydrogenous Os component. We propose that SBC‐1 may be a more suitable reference material to monitor the influence of detrital Re and Os on Re‐Os isochron age data, especially for samples with less organic matter and more siliceous detritus.  相似文献   

13.
The complete dissolution of representative test portions of powdered rock samples for the determination of the mass fractions of trace elements by ICP‐MS relies either on aggressive and time‐consuming acid digestions or fusion/sintering with appropriate fluxes. Here, we evaluate a microwave oven dissolution method that employs a solution of NH4HF2 and HNO3. The entire procedure occurs in a closed vessel system and takes up to 4 h. In hundreds of digestions, the precipitation of fluorides was never observed. Replicate decomposition of 100 mg of twenty‐one international reference materials (RMs) of igneous rocks, and also one of a shale presented mostly satisfactory recoveries of forty‐one trace elements. Important exceptions were Zr and Hf in G‐2 and GSP‐2 (mean recoveries of ca. 70%), although for four other felsic rock RMs, the digestion was complete. For ultramafic rock RMs, we present Cr results that indicate quantitative dissolution of Cr‐bearing phases. We discuss the findings and conclude that advances in sample preparation of geological materials for instrumental analysis would benefit from a better understanding of how specific characteristics, such as composition and crystallinity of certain minerals, may affect their reactivity.  相似文献   

14.
A measurement procedure for determining of Ru, Pd, Ir, Pt and Au mass fractions in ferromanganese deposits by inductively coupled plasma‐mass spectrometry after acid digestion and anion exchange preconcentration is presented. To eliminate incomplete recovery after sorption preconcentration of the platinum‐group elements (PGE) and Au, a standard addition method was used. Detection limits ranged from 0.02 ng (Pd, Ir) to 0.19 ng (Ru). The measurement results for ferromanganese nodule reference material NOD‐A‐1 and NOD‐P‐1 agree with earlier reported values. Intermediate precision of PGE concentration data for nodule reference materials in this work was 5–24% (1s) and could reflect sample heterogeneity.  相似文献   

15.
The in situ measurement of Sr isotopes in carbonates by MC‐ICP‐MS is limited by the availability of suitable microanalytical reference materials (RMs), which match the samples of interest. Whereas several well‐characterised carbonate reference materials for Sr mass fractions > 1000 µg g?1 are available, there is a lack of well‐characterised carbonate microanalytical RMs with lower Sr mass fractions. Here, we present a new synthetic carbonate nanopowder RM with a Sr mass fraction of ca. 500 µg g?1 suitable for microanalytical Sr isotope research (‘NanoSr’). NanoSr was analysed by both solution‐based and in situ techniques. Element mass fractions were determined using EPMA (Ca mass fraction), as well as laser ablation and solution ICP‐MS in different laboratories. The 87Sr/86Sr ratio was determined by well‐established bulk methods for Sr isotope measurements and is 0.70756 ± 0.00003 (2s). The Sr isotope microhomogeneity of the material was determined by LA‐MC‐ICP‐MS, which resulted in 87Sr/86Sr ratios of 0.70753 ± 0.00007 (2s) and 0.70757 ± 0.00006 (2s), respectively, in agreement with the solution data within uncertainties. Thus, this new reference material is well suited to monitor and correct microanalytical Sr isotope measurements of low‐Sr, low‐REE carbonate samples. NanoSr is available from the corresponding author.  相似文献   

16.
Six tourmaline samples were investigated as potential reference materials (RMs) for boron isotope measurement by secondary ion mass spectrometry (SIMS). The tourmaline samples are chemically homogeneous and cover a compositional range of tourmaline supergroup minerals (primarily Fe, Mg and Li end‐members). Additionally, they have homogeneous boron delta values with intermediate precision values during SIMS analyses of less than 0.6‰ (2s). These samples were compared with four established tourmaline RMs, that is, schorl IAEA‐B‐4 and three Harvard tourmalines (schorl HS#112566, dravite HS#108796 and elbaite HS#98144). They were re‐evaluated for their major element and boron delta values using the same measurement procedure as the new tourmaline samples investigated. A discrepancy of about 1.5‰ in δ11B was found between the previously published reference values for established RMs and the values determined in this study. Significant instrumental mass fractionation (IMF) of up to 8‰ in δ11B was observed for schorl–dravite–elbaite solid solutions during SIMS analysis. Using the new reference values determined in this study, the IMF of the ten tourmaline samples can be modelled by a linear combination of the chemical parameters FeO + MnO, SiO2 and F. The new tourmaline RMs, together with the four established RMs, extend the boron isotope analysis of tourmaline towards the Mg‐ and Al‐rich compositional range. Consequently, the in situ boron isotope ratio of many natural tourmalines can now be determined with an uncertainty of less than 0.8‰ (2s).  相似文献   

17.
Measurement of Ba isotope ratios of widely available reference materials is required for interlaboratory comparison of data. Here, we present new Ba isotope data for thirty‐four geological reference materials, including silicates, carbonates, river/marine sediments and soils. These reference materials (RMs) cover a wide range of compositions, with Ba mass fractions ranging from 6.4 to 1900 µg g?1, SiO2 from 0.62% to 90.36% m/m and MgO from 0.08% to 41.03% m/m. Accuracy and precision of our data were assessed by the analyses of duplicate samples and USGS rock RMs. Barium isotopic compositions for all RMs were in agreement with each other within uncertainty. The variation of δ138/134Ba in these RMs was up to 0.7‰. The shale reference sample, affected by a high degree of chemical weathering, had the highest δ138/134Ba (0.37 ± 0.03‰), while the stream sediment obtained from a tributary draining carbonate rocks was characterised by the lowest δ138/134Ba (?0.30 ± 0.05‰). Geochemical RMs play a fundamental role in the high‐precision and accurate determination of Ba isotopic compositions for natural samples with similar matrices. Analyses of these RMs could provide universal comparability for Ba isotope data and enable assessment of accuracy for interlaboratory data.  相似文献   

18.
N(187Os)/N(188Os) ratios of six geological reference materials were measured using static Faraday cups (FCs) with 1013 Ω amplifiers by N‐TIMS. Our results show that the repeatability precision was 2–3‰ (2 RSD,= 3), when taking ~ 1 g of BHVO‐2 with 76 pg g?1 of Os mass fraction and ~ 2 g of BCR‐2 with 21 pg g?1 of Os mass fraction for each sample, whether measured by FCs or by secondary electron multiplier. The repeatability precision measured by FCs was 1–0.2‰ (2 RSD,= 3) when taking ~ 1 g of BIR‐2 with 350 pg g?1 of Os mass fraction, ~ 1 g of WGB‐1 with 493 pg g?1 of Os mass fraction or ~ 0.5 g of WPR‐1 with 13.3 ng g?1 of Os mass fraction for each sample, which is much better than those measured by secondary electron multiplier. Instead, when taking ~ 2 g of AGV‐2 with 4 pg g?1 Os mass fraction, the repeatability precision measured by secondary electron multiplier is 3–4‰ (RSD,= 3), which is better than those measured by FCs. Of the six reference materials analysed, WPR‐1 and BIR‐1a are the most homogeneous with regard to Os isotopic composition (2 RSD of 0.08% and 0.23%, respectively) when test portion masses are 0.5–1 g.  相似文献   

19.
We report an improved procedure for the determination of the platinum‐group elements (PGE) and Re, and Os isotopes from a single sample aliquot by isotope dilution (ID) using inductively coupled plasma‐mass spectrometry (ICP‐MS) and negative thermal ionisation mass spectrometry (N‐TIMS), respectively. A two‐stage column method was used to purify PGE‐Re from their sample matrix and interfering elements (e.g., Mo, Zr and Hf) after Os had been separated by CCl4 solvent extraction. The first column separation step used cation exchange resin (AG50W‐X8) to concentrate PGE‐Re and some potential interfering elements (e.g., Mo, Zr and Hf). In the second step, N‐benzoyl‐N‐phenylhydroxylamine (BPHA) extraction resin was used to separate PGE‐Re from the remaining interfering elements, which all remained strongly absorbed to the resin. The method was used to determine the PGE and rhenium, and Os isotope ratios in a range of geochemical reference materials (TDB‐1, WGB‐1, BHVO‐2 and UB‐N). The obtained results agree well with those previously published. This new method enables PGE‐Re abundances and Os isotopic ratios to be determined on the same sample digestion, and circumvents the problems created by sample heterogeneity when comparing PGE and Re‐Os isotope data.  相似文献   

20.
With implications for the origin of ore deposits, redox state of the atmosphere, and effects of volcanic outgassing, understanding the sulfur cycle is vital to our investigation of Earth processes. However, the paucity of sulfur concentration measurements in silicate rocks and the lack of well‐calibrated reference materials with concentrations relevant to the rocks of interest have hindered such investigations. To aid in this endeavour, this study details a new method to determine sulfur concentration via high mass resolution solution inductively coupled plasma‐mass spectrometry (ICP‐MS). The method is based on an aqua regia leach, involving relatively rapid sample preparation and analysis, and uses small test portion masses (< 50 mg). We utilised two independently prepared standard solutions to calibrate the analyses, resulting in 4% accuracy, and applied the method to eight geochemical reference materials. Measurements were reproducible to within ~ 10%. Sulfur concentrations and isotopes of six reference materials were measured additionally by elemental analyser‐combustion‐isotope ratio mass spectrometry to independently evaluate the accuracy of the ICP‐MS method. Reference materials that yielded reproducible measurements identical to published values from other laboratories (JGb‐1, JGb‐2 and MAG‐1) are considered useful materials for the measurement of sulfur. Reference materials that varied between studies but were reproducible for a given test portion perhaps suffer from sample heterogeneity and are not recommended as sulfur reference materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号