首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper deals with the analysis of groundwater condition in an alluvial aquifer system underlying Kushabhadra-Bhargavi River basin of Odisha, India. The rainfall data and river-stage data of the Kushabhadra River were analyzed for the periods of 1995–2009 and 1991–2010, respectively. Using the available lithologic data, geologic profiles along North-South and East-West sections were prepared and stratigraphy analysis was performed to characterize aquifers and confining layers present in the river basin. The results of stratigraphic analyses indicated that a two-layered aquifer system consisting of an unconfined aquifer and a confined aquifer exists in the study area. The thickness of unconfined aquifer varies from 3.4 to 46.5 m, whereas that of confined aquifer varies from 3.1 to 80.3 m over the basin with an interconnecting confining layer of thickness ranging from 2.1 to 60.0 m. The rainfall-groundwater dynamics and hydraulic connectivity were also investigated for gaining insights into groundwater characteristics. The analysis of groundwater levels indicated that the correlation among the 14 sites is better for most pairs of the sites (r = 0.50 to 0.96) in case of pre-monsoon season’s data and annual data as compared to monsoon and post-monsoon season’s data. This indicates good hydraulic connectivity among the observed sites in the study area. The significant seasonal groundwater fluctuations in the study area indicate appreciable recharge to the aquifer during the monsoon season. The findings obtained and insights gained from this study can be helpful for the water managers and decision makers to understand groundwater dynamics for the efficient planning and management of vital groundwater resources in the region. It is recommended that groundwater monitoring should be continued at more sites to understand long-term spatio-temporal characteristics of groundwater in the study area.  相似文献   

2.
文章从一维地下水运动和渗透力学的角度,分析比较潜水位上升与承压水位下降对岩溶地区透—阻型盖层中阻水层渗透稳定性的影响,重点讨论了承压水位下降速度(降速)与下降深度(降深)对阻水层中渗透坡降的影响,结果表明:地下水位变化(潜水位上升或承压水位下降)产生的非稳定渗流不利于岩溶洞穴开口上方阻水层的稳定,承压水位的下降对岩溶开口附近处阻水层中渗透力的影响远大于潜水位的变化;在承压层水位最大降深确定的条件下,承压水位下降速度愈快,岩溶开口附近处阻水层中向下渗透力愈大。因此,在覆盖型岩溶地区抽取地下水时,为了减缓或避免覆盖型塌陷的发生,应同时控制好最大降深和最大开采速度。   相似文献   

3.
The aquifer of the semi-arid Kairouan plain has been exploited for decades to supply the growing irrigated agriculture and the need of drinking water. In parallel, the major hydraulic works drastically changed the natural groundwater recharge processes. The continuous groundwater level drop observed since the 1970s naturally raises the question of groundwater storage sustainability. To date, hydrogeological studies focused on groundwater fluxes, but the total amount of groundwater stored in the aquifer system has never been fully estimated. This is the purpose of the present paper. A complete database of all available geological, hydrogeological and geophysical data was created to build a 3D lithology model. Then, the lithological units were combined with the hydraulic properties to estimate the groundwater storage. Over the 700 km2 of the modelled area, the estimated storage in 2013 was around 18?×?109 m3 (equivalent to 80 times the annual consumption of 2010) with a highly variable spatial distribution. In 45 years (1968–2013), 12% of the amount of groundwater stored in the aquifer has been depleted. According to these results, individual farms will face strong regional disparities for their access to groundwater in the near future.  相似文献   

4.
A significant component of domestic demand for water of urban areas located in the Gangetic plains is met by heavy pumping of groundwater. The present study is focused on the Patna municipal area, inhabited by 17 million people and spanning over 134 km2, where entire urban water demand is catered from pumping by wells of various capacities and designs. The present study examines the nature of the aquifer system within the urban area, the temporal changes in the water/piezometric level and the recharge mechanism of the deeper aquifers. The aquifer system is made up of medium-to-coarse unconsolidated sand, lying under a ~40-m-thick predominantly argillaceous unit holding 8- to 13-m-thick localised sand layers and continues up to 220 m below ground. Groundwater occurs under semi-confined condition, with transmissivity of aquifers in 5,500–9,200 m2 day?1 range. Hydraulic head of the deeper aquifer remains in 9–19 m range below ground, in contrast to 1–9 m range of that of the upper aquitard zone. The estimated annual groundwater extraction from the deeper aquifer is ~212.0 million m3, which has created a decline of 3.9 m in the piezometric level of the deeper aquifer during the past 30 years. Unregulated construction of deep tube wells with mushrooming of apartment culture may further exacerbate the problem. The sand layers within the aquitard zone are experiencing an annual extraction of 14.5 million m3 and have exhibited stable water level trend for past one and half decades. This unit is recharged from monsoon rainfall, besides contribution from water supply pipe line leakage and seepage from unlined storm water drains.  相似文献   

5.
The efficiency of GIS, RS and multi-criteria tools in isolating potential groundwater (GW) zones in the Kuttiyadi River basin (KRB), Kerala, has been robustly demonstrated by analysis of relevant data. To infer geohydrological makeup and consequent behavior of the KRB in respect of GW potential, firstly, various thematic layers viz. geomorphology, geology, slope, soil, lineament density and drainage density, were created. Secondly, thematic layers and their features were assigned suitable weights on the Saaty’s scale according to their relative significance for the presence and potential of GW. The assigned weights of the layers and their features were normalized using analytic network process method, and then the selected thematic maps were integrated in GIS using weighted overlay method to create the final groundwater prospect zone map. From the outcomes, the groundwater prospect zones of the KRB basin was found to be very good (166.21 km2), good (92.01 km2), moderate (180.33 km2), poor (237.25 km2), which constitute 24, 15, 26 and 35% of the study area, respectively. The GW prospect zone map was finally validated using geohydrology of area and GW level data from 43 phreatic wells in the study area. This study showed that groundwater prospect zone demarcation along with multi-criteria decision making is a powerful tool for proper utilization, planning and management of the precious groundwater resource.  相似文献   

6.
A numerical groundwater model of the weathered crystalline aquifer of Ursuya (a major water source for the north-western Pyrenees region, south-western France) has been computed based on monitoring of hydrological, hydrodynamic and meteorological parameters over 3 years. The equivalent porous media model was used to simulate groundwater flow in the different layers of the weathered profile: from surface to depth, the weathered layer (5?·?10?8?≤?K?≤?5?·? 10?7 m s?1), the transition layer (7?·?10?8?≤?K?≤?1?·? 10?5 m s?1, the highest values being along major discontinuities), two fissured layers (3.5?·?10?8?≤?K?≤?5?·?? 10?4 m s?1, depending on weathering profile conditions and on the existence of active fractures), and the hard-rock basement simulated with a negligible hydraulic conductivity (K = 1 10 ?9 ). Hydrodynamic properties of these five calculation layers demonstrate both the impact of the weathering degree and of the discontinuities on the groundwater flow. The great agreement between simulated and observed hydraulic conditions allowed for validation of the methodology and its proposed use for application on analogous aquifers. With the aim of long-term management of this strategic aquifer, the model was then used to evaluate the impact of climate change on the groundwater resource. The simulations performed according to the most pessimistic climatic scenario until 2050 show a low sensitivity of the aquifer. The decreasing trend of the natural discharge is estimated at about ?360 m3 y?1 for recharge decreasing at about ?5.6 mm y?1 (0.8 % of annual recharge).  相似文献   

7.
The paper aims at evaluating the interaction between ground and surface water along the Langat River in Malaysia through the development of a numerical simulation. Malaysia has been experiencing a rapid economic growth since the last few decades, driven by many factors such as agriculture, industry, and the like. The demand for water in these sectors has increased so tremendously that surface water has been utilized in conjunction to groundwater. Approximately 18,184 m3 of water per day is obtained from the aquifer to supply to the steel factory. There are also workshops, petroleum stations, and houses in the area thus causing the water quantity and quality to degrade. In terms of quantity, the pumping activity has altered the interaction between the groundwater and surface water. Therefore, a numerical model was proposed and two aquifer layers were simulated, with the first layer being approximately >20 m in depth and the second layer >100 m. The recharge estimated from the tank model was input into the groundwater modeling. The effects of the surface water to the aquifer were included in the simulation by defining the river conductance, river bed, and river level. The calibrated model (error about 0.9 m) was achieved and applied to predict the flow pattern in its natural state without the pumping and with the pumping states. As a result, in the first scenario, the stream was in an effluent condition influenced by the groundwater from the northeast to the west. A hyporheic flow occurred and was observed from the contour map. The flow system was changed in the second scenario when the pumping activity was included in the simulation. The groundwater lost its original function but received leakage from the stream near the pumping sites. The findings of this study will help the local authorities and other researchers to understand the aquifer system in the area and assist in the preparation of a sustainable groundwater management.  相似文献   

8.
The origin and movement of groundwater are the fundamental questions that address both the temporal and spatial aspects of ground water run and water supply related issues in hydrological systems. As groundwater flows through an aquifer, its composition and temperature may variation dependent on the aquifer condition through which it flows. Thus, hydrologic investigations can also provide useful information about the subsurface geology of a region. But because such studies investigate processes that follow under the Earth's shallow, obtaining the information necessary to answer these questions is not continuously easy. Springs, which discharge groundwater table directly, afford to study subsurface hydrogeological processes.The present study of estimation of aquifer factors such as transmissivity (T) and storativity (S) are vital for the evaluation of groundwater resources. There are several methods to estimate the accurate aquifer parameters (i.e. hydrograph analysis, pumping test, etc.). In initial days, these parameters are projected either by means of in-situ test or execution test on aquifer well samples carried in the laboratory. The simultaneous information on the hydraulic behavior of the well (borehole) that provides on this method, the reservoir and the reservoir boundaries, are important for efficient aquifer and well data management and analysis. The most common in-situ test is pumping test performed on wells, which involves the measurement of the fall and increase of groundwater level with respect to time. The alteration in groundwater level (drawdown/recovery) is caused due to pumping of water from the well. Theis (1935) was first to propose method to evaluate aquifer parameters from the pumping test on a bore well in a confined aquifer. It is essential to know the transmissivity (T = Kb, where b is the aquifer thickness; pumping flow rate, Q = TW (dh/dl) flow through an aquifer) and storativity (confined aquifer: S = bSs, unconfined: S = Sy), for the characterization of the aquifer parameters in an unknown area so as to predict the rate of drawdown of the groundwater table/potentiometric surface throughout the pumping test of an aquifer. The determination of aquifer's parameters is an important basis for groundwater resources evaluation, numerical simulation, development and protection as well as scientific management. For determining aquifer's parameters, pumping test is a main method. A case study shows that these techniques have been fast speed and high correctness. The results of parameter's determination are optimized so that it has important applied value for scientific research and geology engineering preparation.  相似文献   

9.
Globally, aquifers are suffering from large abstractions resulting in groundwater level declines. These declines can be caused by excessive abstraction for drinking water, irrigation purposes or industrial use. Basaltic aquifers also face these conflicts. A large flood basalt area (1.1?×?105 km2) can be found in the Northwest of the USA. This Columbia River Basalt Group (CRBG) consists of a thick series of basalt flows of Miocene age. The two major hydrogeological units (Wanapum and Grand Ronde formations) are widely used for water abstraction. The mean decline over recent decades has been 0.6 m year?1. At present day, abstraction wells are drying up, and base flow of rivers is reduced. At the eastern part of CRBG, the Moscow sub-basin on the Idaho/Washington State border can be found. Although a thick poorly permeable clay layer exists on top of the basalt aquifer, groundwater level dynamics suggest that groundwater recharge occurs at certain locations. A set of wells and springs has been monitored bi-weekly for 9 months for δ18O and δ2H. Large isotopic fluctuations and d-excess values close to the meteoric water line in some wells are indicating that recharge occurs at the granite/basalt interface through lateral flow paths in and below the clay. A soil moisture routing (SMR) model showed that most recharge occurs on the granitic mountains. The basaltic aquifer receives recharge from these sedimentary zones around the granite/basalt interface. The identification of these types of areas is of major importance for future managed-aquifer recharge solutions to solve problems of groundwater depletion.  相似文献   

10.
Inter-basin water transfer projects (IBWTPs) can involve basins as water donors and water receivers. In contrast to most studies on IBWTPs, which mainly impact the surface-water eco-environment, this study focuses on the impacts of an IBWTP on groundwater and its eco-environment in a water donor basin in an arid area, where surface water and groundwater are exchanged. Surface water is assumed to recharge groundwater and a groundwater numerical simulation model was constructed using MODFLOW. The model was used to quantitatively evaluate the impact of an IBWTP located in the upstream portion of Nalenggele River (the biggest river in the Qaidam basin, Northwest China). The impact involved decrease in spring flow, drawdown of groundwater, reduction in oasis area, and an increase in species replacement of oasis vegetation in the midstream and downstream of the river. Results show that the emergence sites of springs at the front of the oasis will move 2–5 km downstream, and the outflow of springs will decrease by 42 million m3/a. The maximum drawdown of groundwater level at the front of the oasis will be 3.6 m and the area across which groundwater drawdown exceeds 2.0 m will be about 59.02 km2, accounting for 2.71% of the total area of the oasis. Under such conditions, reeds will gradually be replaced by Tamarix, shrubs, and other alternative plant species. These findings have important implications for the optimization of water resource allocation and protection of the eco-environment in arid regions.  相似文献   

11.
Arsenic occurrence in groundwater near the Cimino-Vico volcanoes (central Italy) was analysed considering the hydrostratigraphy and structural setting and the shallow and deep flows interacting within the Quaternary volcanics. Groundwater is the local source of drinking water. As documented in the past, arsenic in the groundwater has become a problem, and the European maximum allowable contaminant level was recently lowered to 10 μg/L. Chemical analyses of groundwater were conducted, sampled over an area of about 900 km2, from 65 wells and springs representative of the volcanic aquifer and thermal waters. Considering the type of aquifer, the nature of the aquifer formation and its substratum, the hydrochemical data highlight that the arsenic content of the groundwater is mainly connected with the hydrothermal processes in the volcanic area. Thermal waters (54–60°C) fed from deep-rising fluids show higher arsenic concentrations (176–371 μg/L). Cold waters sampled from the volcanic aquifer are characterized by a wide variability in their arsenic concentration (1.6–195 μg/L), and about 62% exceed the limit of 10 μg/L. Where the shallow volcanic aquifer is open to deep-rising thermal fluids, relatively high arsenic concentrations (20–100 μg/L) are found. This occurs close to areas of the more recent volcano-tectonic structures.  相似文献   

12.
Groundwater in shallow unconsolidated sedimentary aquifers close to the Bornheim fault in the Lower Rhine Embayment (LRE), Germany, has relatively low δ2H and δ18O values in comparison to regional modern groundwater recharge, and 4He concentrations up to 1.7?×?10?4 cm3 (STP) g–1?±?2.2 % which is approximately four orders of magnitude higher than expected due to solubility equilibrium with the atmosphere. Groundwater age dating based on estimated in situ production and terrigenic flux of helium provides a groundwater residence time of ~107 years. Although fluid exchange between the deep basal aquifer system and the upper aquifer layers is generally impeded by confining clay layers and lignite, this study’s geochemical data suggest, for the first time, that deep circulating fluids penetrate shallow aquifers in the locality of fault zones, implying  that sub-vertical fluid flow occurs along faults in the LRE. However, large hydraulic-head gradients observed across many faults suggest that they act as barriers to lateral groundwater flow. Therefore, the geochemical data reported here also substantiate a conduit-barrier model of fault-zone hydrogeology in unconsolidated sedimentary deposits, as well as corroborating the concept that faults in unconsolidated aquifer systems can act as loci for hydraulic connectivity between deep and shallow aquifers. The implications of fluid flow along faults in sedimentary basins worldwide are far reaching and of particular concern for carbon capture and storage (CCS) programmes, impacts of deep shale gas recovery for shallow groundwater aquifers, and nuclear waste storage sites where fault zones could act as potential leakage pathways for hazardous fluids.  相似文献   

13.
The combined effects of low rainfall, groundwater withdrawal in excess of 300 GL/year and reduced recharge in areas covered by pine plantations has caused the water table in a sandy unconfined aquifer on the Gnangara Mound in Western Australia to drop by up to 5 m and aquifer storage to decline by about 500 GL over the last 20 years. Groundwater has become acidic in areas of high drawdown, with pH values typically being less than 5.0 at the water table, and elevated concentrations of SO4 2?, Al, Fe, Zn, Cu, Ni and Pb. Trends of increasing acidity and base cation concentrations in deep water supply wells in the Mirrabooka wellfield indicate that about 0.7 keq/ha/year of base cations are being leached from soil within cones of depression of pumping wells. These results indicate that the assessment of the sustainable yields of aquifers under conditions of low rainfall needs to consider geochemical interactions between groundwater, aquifer sediments, soils and vegetation, and not be just based on aquifer hydraulics and water-balance changes.  相似文献   

14.
The study area is a part of central Ganga Plain which lies within the interfluve of Hindon and Yamuna rivers and covers an area of approximately 1,345 km2. Hydrogeologically, Quaternary alluvium hosts the major aquifers. A fence diagram reveals the occurrence of a single aquifer to a depth of 126 m below ground level which is intercalated by sub-regional clay beds. The depth to water level ranges from 9.55 to 28.96 m below ground level. The general groundwater flow direction is northwest to southeast. Groundwater is the major source of water supply for agricultural, domestic, and industrial uses. The overuse of groundwater has resulted in the depletion of water and also quality deterioration in certain parts of the area. This has become the basis for the preparation of a groundwater vulnerability map in relation to contamination. The vulnerability of groundwater to contamination was assessed using the modified DRASTIC-LU model. The parameters like depth to water, net recharge, aquifer media, soil media, topography, impact of vadose zone, hydraulic conductivity of the aquifer, and land use pattern were considered for the preparation of a groundwater vulnerability map. The DRASTIC-LU index is computed as the sum of the products of weights and rating assigned to each of the inputs considered. The DRASTIC-LU index ranges from 158 to 190, and is classified into four categories, i.e., <160, 160–170, 170–180, and >180, corresponding to low, medium, high, and very high vulnerability zones, respectively. Using this classification, a groundwater vulnerability potential map was generated which shows that 2 % of the area falls in the low vulnerable zone, 38 % falls in the medium vulnerable zone, and 49 % of the area falls in the high vulnerable zone. About 11 % of the study area falls in the very high vulnerability zone. The groundwater vulnerability map can be used as an effective preliminary tool for the planning, policy, and operational levels of the decision-making process concerning groundwater management and protection.  相似文献   

15.
Groundwater response to stream stage fluctuations was studied in two unconfined alluvial aquifers using a year-long time series of stream stages from two pools along a regulated stream in West Virginia, USA. The purpose was to analyze spatial and temporal variations in groundwater/surface-water interaction and to estimate induced infiltration rate and cumulative bank storage during an annual cycle of stream stage fluctuation. A convolution-integral method was used to simulate aquifer head at different distances from the stream caused by stream stage fluctuations and to estimate fluxes across the stream–aquifer boundary. Aquifer diffusivities were estimated by wiggle-matching time and amplitude of modeled response to multiple observed storm events. The peak lag time between observed stream and aquifer stage peaks ranged between 14 and 95 hour. Transient modeled diffusivity ranged from 1,000 to 7,500 m2/day and deviated from the measured and calculated single-peak stage-ratio diffusivity by 14–82 %. Stream stage fluctuation displayed more primary control over groundwater levels than recharge, especially during high-flow periods. Dam operations locally altered groundwater flow paths and velocity. The aquifer is more prone to surface-water control in the upper reaches of the pools where stream stage fluctuations are more pronounced than in the lower reaches. This method could be a useful tool for quick assessment of induced infiltration rate and bank storage related to contamination investigations or well-field management.  相似文献   

16.
Land subsidence caused by groundwater exploitation in Suzhou City,China   总被引:10,自引:2,他引:10  
Suzhou City, located at the lower reaches of the Yangtze River in southeastern Jiangsu Province, is one of the few cities in China which suffer from severe ground settlement. A research project was carried out to investigate this problem. Geological and hydrogeological studies show that there is a multi-layered aquifer system with three distinct, soft mud layers of marine and lagoonal origins. An examination of historical records of groundwater extraction, water levels, and ground settlement shows that the ground subsidence is associated with the continuously increasing groundwater extraction in the deep, confined aquifer. It is believed that the consolidation of the soft mud layers, especially the third layer which is thick and close to the main pumped aquifer, contributes to the ground settlement. A three-dimensional finite difference numerical model representing the multi-layered aquifer system was developed to study the ground settlement in response to groundwater extraction. By calibrating the model with both the measured groundwater level and ground settlement, the aquifer parameters were estimated. The model outputs fit reasonably well with the observed results, which indicates that the numerical model can reproduce the dynamic processes of both groundwater flow and soil consolidation. The hydraulic conductivity of the third mud layer near the center of the ground settlement has been reduced by over 30% in the last 14 years. The gradual deterioration in the hydraulic conductivity of the mud may have significant adverse effect on the sustainable groundwater resource of the deep confined aquifer, since the recharge from the shallow aquifers through the mud layer is the only source of water to the deep aquifer. An analysis of the spatial distributions of groundwater drawdown and ground settlement shows that the area with maximum drawdown is not necessarily the area with maximum ground settlement due to the occurrence of the soft mud layer. A simple reallocation in pumping rates on the basis of the spatial distribution of the thick mud layer could significantly reduce the ground settlement. Electronic Publication  相似文献   

17.
The Middle East and North Africa (MENA) region is the world’s most water-stressed region, with its countries constituting 12 of the 15 most water-stressed countries globally. Because of data paucity, comprehensive regional-scale assessments of groundwater resources in the MENA region have been lacking. The presented study addresses this issue by using a distributed ArcGIS model, parametrized with gridded data sets, to estimate groundwater storage reserves in the region based on generated aquifer saturated thickness and effective porosity estimates. Furthermore, monthly gravimetric datasets (GRACE) and land surface parameters (GLDAS) were used to quantify changes in groundwater storage between 2003 and 2014. Total groundwater reserves in the region were estimated at 1.28 × 106 cubic kilometers (km3) with an uncertainty range between 816,000 and 1.93 × 106 km3. Most of the reserves are located within large sedimentary basins in North Africa and the Arabian Peninsula, with Algeria, Libya, Egypt, and Saudi Arabia accounting for approximately 75% of the region’s total freshwater reserves. Alternatively, small groundwater reserves were found in fractured Precambrian basement exposures. As for groundwater changes between 2003 and 2014, all MENA countries except for Morocco exhibited declines in groundwater storage. However, given the region’s large groundwater reserves, groundwater changes between 2003 and 2014 are minimal and represent no immediate short-term threat to the MENA region, with some exceptions. Notwithstanding this, the study recommends the development of sustainable and efficient groundwater management policies to optimally utilize the region’s groundwater resources, especially in the face of climate change, demographic expansion, and socio-economic development.  相似文献   

18.
In groundwater hydrology, aquitard heterogeneity is often less considered compared to aquifers, despite its significant impact on groundwater hydraulics and groundwater resources evaluation. A semi-analytical solution is derived for pumping-induced well hydraulics and groundwater budget with consideration of vertical heterogeneity in aquitard hydraulic conductivity (K) and specific storage (Ss). The proposed new solution is innovative in its partitioning of the aquitard into multiple homogeneous sub-layers to enable consideration of various forms of vertically heterogeneous K or Ss. Two scenarios of analytical investigations are explored: one is the presence of aquitard interlayers with distinct K or Ss values, a common field-scale occurrence; another is an exponentially depth-decaying aquitard Ss, a regional-scale phenomenon supported by statistical analysis. Analytical investigations reveal that a low-K interlayer can significantly increase aquifer drawdown and enhance aquifer/aquitard depletion; a high-Ss interlayer can noticeably reduce aquifer drawdown and increase aquitard depletion. Locations of low-K or high-Ss interlayers also significantly impact well hydraulics and groundwater budget. In the context of an exponentially depth-decaying aquitard Ss, a larger decay exponent can enhance aquifer drawdown. When using current models with a vertically homogeneous aquitard, half the sum of the geometric and harmonic means of exponentially depth-decaying aquitard Ss should be used to calculate aquitard depletion and unconfined aquifer leakage.  相似文献   

19.
Corrected groundwater 14C ages from the carbonate aquifer in Yucca Flat at the former Nevada Test Site (now the Nevada National Security Site), USA, were evaluated by comparing temporal variations of groundwater 36Cl/Cl estimated with these 14C ages with published records of meteoric 36Cl/Cl variations preserved in packrat middens (piles of plant fragments, fecal matter and urine). Good agreement between these records indicates that the groundwater 14C ages are reasonable and that 14C is moving with chloride without sorbing to the carbonate rock matrix or fracture coatings, despite opposing evidence from laboratory experiments. The groundwater 14C ages are consistent with other hydrologic evidence that indicates significant basin infiltration ceased 8,000 to 10,000 years ago, and that recharge to the carbonate aquifer is from paleowater draining through overlying tuff confining units along major faults. This interpretation is supported by the relative age differences as well as hydraulic head differences between the alluvial and volcanic aquifers and the carbonate aquifer. The carbonate aquifer 14C ages suggest that groundwater velocities throughout much of Yucca Flat are about 2 m/yr, consistent with the long-held conceptual model that blocking ridges of low-permeability rock hydrologically isolate the carbonate aquifer in Yucca Flat from the outlying regional carbonate flow system.  相似文献   

20.
A combination of vertical electrical soundings (VES), 2D electrical resistivity imaging (ERI) surveys and borehole logs were conducted at Magodo, Government Reserve Area (GRA) Phase 1, Isheri, Southwestern Nigeria, with the aim of delineating the different aquifers present and assessing the groundwater safety in the area. The Schlumberger electrode array was adopted for the VES and dipole-dipole array was used for the 2D imaging. The maximum current electrode spread (AB) was 800 m and the 2D traverse range between 280 and 350 m in the east-west direction. The thickness of impermeable layer overlying the confined aquifer was used for the vulnerability ratings of the study area. Five lithological units were delineated: the topsoil, clayey sand, unconsolidated sand which is the first aquifer, a clay stratum and the sand layer that constitutes the confined aquifer horizon. The topsoil thickness varies from 0.6 to 2.6 m, while its resistivity values vary between 55.4 and 510.6 Ω/m. The clayey sand layers have resistivity values ranging from 104.2 to 143.9 Ω/m with thickness varying between 0.6 and 14.7 m. The resistivity values of the upper sandy layer range from 120.7 to 2195.2 Ω/m and thickness varies from 3.3 to 94.0 m. The resistivity of the clay layer varies from 11.3 to 96.1 Ω/m and the thickness ranges from 29.6 to 76.1 m. The resistivity value of the confined aquifer ranges between 223 and 1197.4 Ω/m. The longitudinal conductance (0.0017–0.02 mhos) assessment of the topsoil shows that the topsoil within the study area has poor overburden protective capacity, and the compacted impermeable clay layer shows that the underlying confined aquifer is well protected from contamination and can be utilized as a source of portable groundwater in the study area. This study therefore enabled the delineation of shallow aquifers, the variation of their thicknesses and presented a basis for safety assessment of groundwater potential zones in the study area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号