首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Surface electrical and electromagnetic surveys were conducted on top of a solid waste facility in Unguwan Dosa, Kaduna State, Northwest Nigeria. The aim of the geophysical survey was to detect vertical and subvertical fractures that may provide pathways for groundwater and contaminant transport. Results from the 2D electrical resistivity imaging showed vertical and subvertical contacts overlain by 6–10 m thick overburden. Quantitative interpretation of the VLF-EM data correlates well with the results of the 2D resistivity imaging delineating the vertical and subvertical contacts as good and weak conductors (fractures zones) with resistivity values of 40–220 and 300–420 Ω m, respectively. Azimuthal Schlumberger VES measurements yield apparent anisotropy values ranging from 1.01 to 1.47 for electrode spacings of 1–45 m with the highest value recorded at spacing of 2 m. However, azimuthal variations at large spacings (30–45 m) showed no fracture anisotropy due possibly to the array’s low sensitivity to anisotropy at these spacings. The result of the study showed that pollutants in the leachate can reach and contaminate the groundwater. Therefore, urgency for leachate treatment at this site is recommended to prevent contamination of groundwater.  相似文献   

2.
Recently, the deterioration of water quality in the coastal zones of Lekki Peninsula area of Lagos due to saltwater infiltration into the freshwater aquifer has become a major concern. With the aim of providing valuable information on the hydrogeologic system of the aquifers, the subsurface lithology and delineating the groundwater salinity, vertical electrical resistivity (VES) sounding survey was carried out utilizing surface Schlumberger electrode arrays, and electrode spacing varying between 1 and 150 m. The DC resistivity surveys revealed significant variations in subsurface resistivity. Also, the VES resistivity curves showed a dominant trend of decreasing resistivity with depth (thus increasing salinity). In general, the presence of four distinct resistivity zones were delineated viz.: the unconsolidated dry sand (A) having resistivity values ranging between 125 and 1,028 Ωm represent the first layer; the fresh water-saturated soil (zone B) having resistivity values which correspond to 32–256 Ωm is the second layer; the third layer (zone C) is interpreted as the mixing (transition) zone of fresh with brackish groundwater. The resistivity of this layer ranges from 4 to 32 Ωm; while layer four (zone D) is characterized with resistivities values generally below 4 Ωm reflecting an aquifer possibly containing brine. The rock matrix, salinity and water saturation are the major factors controlling the resistivity of the formation. Moreover, this investigation shows that saline water intrusion into the aquifers can be accurately mapped using surface DC resistivity method.  相似文献   

3.
This research is an attempt to accomplish a 3-D resistivity imaging survey, which was carried out near a water well contaminated with hydrocarbon materials in Karbala governorate. Two-dimensional resistivity imaging measurements were collected along four parallel profiles, using a Wenner array with electrode spacing of 1 m. The RES3DINV program was used to invert the apparent resistivity data. The results displayed a resistivity distribution of the subsurface in a three-dimensional volume. Thus, both the horizontal and vertical extents of the contaminated zone were displayed. This technique revealed a low resistivity zone at depth ranges from 3 to 6 m in the investigation area, but the seepage starts at depth ranges between 2 and 3 m and continues down depth (may be to the groundwater level). This low resistivity zone is the most likely location for a subsurface seepage of contaminated water. It is clear that the sufficient measurement points along 2-D lines in a small area can increase the 3-D imaging resolution, and nearly real 3-D imaging can be achieved, when the size of subsurface anomaly compared with the electrode spacing (a) of the Wenner array is taken into consideration.  相似文献   

4.
李瑛  龚晓南 《岩土力学》2012,33(1):89-95
通过室内1:5的模型试验进行了等电势梯度下2 m×1 m和1 m×0.5 m两种工程常见矩形布置电极间距下的软黏土电渗性状的研究。利用监测排水量、排水速率、电流、电势、含水率和pH值等指标,对不同电极间距试样的电渗处理效果、能量效率和电极腐蚀等方面进行了分析。结果表明:保持电势梯度不变而减半电极间距能够加快电渗排水,降低土体含水率,减小能量消耗和电极界面电阻,但也会导致土体pH值变化和阳极腐蚀量的增大。此外,采用较小的电极间距可使损失在电极和土接触面上的电势降减小,但损失的电势降占电源电压的比例增大。  相似文献   

5.
A geoelectrical resistivity survey using vertical electrical sounding (VES) was conducted at Chaj Doab (land between rivers Jhelum and Chenab, Pakistan) and Rachna Doab (land between rivers Chenab and Ravi, Pakistan), with the objective of investigating groundwater conditions. A total of 90 sites were selected with 43 sites in Chaj and 47 sites in Rachna Doabs. The resistivity meter (ABEM Terrameter SAS 4000, Sweden) was used to collect the VES data by employing a Schlumberger electrode configuration, with half current electrode spacings (AB/2) ranging from 2 to 180 m and the potential electrode (MN) from 1 to 40 m. The field data were interpreted using the Interpex IX1D computer software and the resistivity versus depth models for each location was estimated. The outputs of subsurface layers with resistivities and thickness presented in contour maps and 3-D views by using SURFER software were created. A total of 102 groundwater samples from nearby hydrowells at different depths were collected to develop a correlation between the aquifer resistivity of VES and the electrical conductivity (EC) of the groundwater and to confirm the resulted geophysical resistivity models. From the correlation developed, it was observed that the groundwater salinity in the aquifer may be considered low and so safe for irrigation if resistivity >45 Ω m, and marginally fit for irrigation having resistivity between 25 and 45 Ω m. The study area has resistivities from 3.9 to 2,222 Ω m at the top of the unsaturated layer, between 1.21 and 171 Ω m, in the shallow aquifers, and 0.14–152 Ω m in the deep aquifers of the study area. The results indicate that the quality of groundwater is better near the rivers and in the shallow layers compared to the deep layers.  相似文献   

6.
Electrical resistivity surveying for delineating seawater intrusion was performed in the Dibdibba aquifer in the area between the cities of Al-Zubair–Safwan and Al-Zubair–Umm Qasr in the vicinity of Khor AL-Zubair Channel, Basrah governorate, southern Iraq. Fourteen 2D resistivity profiles with a total length of 14 km were collected in the study area. The resistivity sections were compared with lithological data extracted from 11 boreholes. Thirty-nine groundwater samples were collected within the area and analyzed for chemical constituents; internal hydrogeological reports and unpublished studies were also evaluated. Results reveal the existence of three major resistivity layers, ranging from 0.1 to 130 Ωm at various depths and locations. The first layer has very low electrical resistivity (0.1–5 Ωm) representing a layer saturated with saltwater intruded from Khor AL-Zubair Channel. The second layer shows resistivity in the range of 5–130 Ωm, attributed to a transition zone and an unaffected zone saturated with brackish groundwater. The last resistivity layer (<?3 Ωm) represents coarse-grain sediments saturated with saline groundwater. Furthermore, a hard clay bed (Jojab) appears with a resistivity of 3–7 Ωm in all 2D imaging lines within a depth of 20–28 m. Electrical conductivity (EC) measurements from seven wells collected in 2014 and 2016 show a positive EC difference increasing landward with an average increase of 1927 µS/cm. In addition, six chemical relationships (Na/Cl, [Ca?+?Mg]/[HCO3?+?SO4], SO4/HCO3, SO4/Cl, Mg/Ca and Cl/[HCO3?+?CO3]) are used to detect the source of salinity in groundwater. This study proves that extensive use of high-resolution 2D imaging sections, alongside lithological and hydrogeological data, can serve as a useful tool to delineate the boundaries between aquifers, identify hydraulic boundaries between groundwater with different salinities and allocate hard clay layers between the upper and lower Dibdibba aquifer. In general, the combination of 2D imaging and hydrochemistry enables conceptualization of the hydrogeological situation in the subsurface and characterization of the salinity source, here seawater intrusion, in the study area. There have been no studies published so far on the characteristics of saltwater intrusion in the study area, and this study is considered to be important for monitoring and studying the intrusion and regression of seawater.  相似文献   

7.
The current study is carried out for the determination of groundwater potential in District Rawalakot Azad Jammu and Kashmir (AJ&K) Pakistan by using electrical resistivity method and petrographic analysis of the area. The tape-compass-clinometers method was used in section measurement to understand the facies and depositional environment. The electrical resistivity survey was carried out in the project area in sub-Himalayan Siwaliks system of Pakistan to overcome water scarcity in a few regions. The area was chartered with the Schlumberger configuration up to the AB/2 depth of 150 m. The ABEM Terrameter SAS 4000 (Sweden) and accessories were used to acquire vertical electrical soundings in 24 locations. The results obtained through the 2D and 3D isoresistivity maps of apparent resistivity for 15, 45, and 130 m spacings, the 3D isoresistivity maps of transverse resistance and anisotropy, the VES curve types, and the measured stratigraphic section of surface rocks revealed the confined or semi-confined type aquifers within sedimentary formations. The petrographic analysis indicates the clues of the secondary porosity and fluid migrations through the rocks.  相似文献   

8.
Long-period natural-source electromagnetic data have been recorded using portable three-component magnetometers at 39 sites in 1998 and 2002 across the southern Eyre Peninsula, South Australia that forms part of the Gawler Craton. Site spacing was of order 5 km, but reduced to 1 km or less near known geological boundaries, with a total survey length of approximately 50 km. A profile trending east – west was inverted for a 2D electrical resistivity model to a depth of 20 km across the southern Eyre Peninsula. The main features from the models are: (i) on the eastern side of the Gawler Craton, the Donington Suite granitoids to the east of the Kalinjala Shear Zone are resistive (>1000 Ωm); (ii) the boundary between the Donington Suite granitoids and the Archaean Sleaford Complex, which has much lower resistivity of 10 – 100 Ωm, is almost vertical in the top 10 km and dips slightly westwards; and (iii) two very low resistivity (<1 Ωm) arcuate zones in the top 3 km of Hutchison Group sediments correlate with banded iron-formations, and are probably related to biogenic-origin graphite deposits concentrated in fold hinges. Such features suggest an extensional regime during the time period 2.00 – 1.85 Ga. We suggest that the resistivity boundary between the Donington Suite and the Archaean Sleaford Complex represents a growth fault, typical for rift systems that evolve into a half-graben structure. In the graben basin, low-resistivity shallow-marine Hutchison Group sediments were deposited. Folding of the sediments during the Kimban Orogeny between 1.74 and 1.70 Ga has led to migration of graphite to the fold hinges resulting in linear zones of very low resistivity that correlate with banded iron-formation magnetic anomalies.  相似文献   

9.
高密度电法在反演过程中,电极距相比电性异常体横向长度过大时,电性异常体在反演中无法得到约束;某电极距下,当电性异常体埋藏深度增加大到一定深度时,在反演中电性异常体也无法得到约束。针对以上两个问题,利用res2dmod正演软件建立模型,再利用res2dinv反演软件对模型进行反演,通过对比分析结果表明:温纳、偶极和微分三种装置分两种情况:如果电极距小于20m模拟条件下,对于埋藏深度为5m且剖面面积不同的电性异常高阻体(异常体电阻率=100Ω·m,围岩电阻率=10Ω·m),横向反演分辨率,温纳装置大于微分和偶极装置;电极距小于12.75m时,微分装置大于偶极装置,电极距大于12.75m时,偶极装置大于微分装置。如果电极距在2m^8m范围内,对于剖面面积为4×4(m2)的电性异常高阻体(异常体电阻率=100Ω·m,围岩电阻率=10Ω·m),其最大约束深度随电极距的增大而先增大后减小;相同电极距下,偶极装置的最大约束深度>微分装置的最大约束深度>温纳装置的最大约束深度。  相似文献   

10.
The objective of this study was to assess the subsurface strata and groundwater situation of Olomoro, Nigeria using borehole logging and electrical resistivity techniques. The borehole logging consisting of resistivity and spontaneous potential logs were conducted by using the Johnson Keck logger on a drilled well in the study area. The electrical resistivity survey involving 17 vertical electrical soundings (VES) with a maximum current electrode spacing of 100 to 150 m was conducted using the Schlumberger electrode configuration. Analysis of the well cuttings revealed that the lithology of the subsurface consist of topsoil, clay, very fine sand, medium grain sand, coarse sand and very coarse sand. Results of the downhole logging also revealed that the mean electrical conductivity and the total dissolved solid of the groundwater was obtained as 390 μS/cm and 245 mg/cm3 respectively. These values are within the acceptable limit set by the Standard Organization of Nigeria (SON) for drinking water. The result of the vertical electrical sounding interpreted using the computer iterative modeling revealed the presence of four to five geoelectric layers which showed a close correlation with result from the lithology and downhole logging. Results further showed that the resistivity of the subsurface aquifer ranged between 1584 and 5420 Ωm while the aquifer depths varied between 27.8 and 39.3 m. Groundwater development of the area is suggested using the depth and resistivity maps provided in this study.  相似文献   

11.
高阻碳酸盐岩中的低阻断层和充水溶洞是岩溶区地下水勘查的主要目标体。根据高阻中找低阻的原则,建立碳酸盐岩类裂隙溶洞水赋存模式的断层-溶洞地电模型,利用RES3D软件进行温纳、施伦贝格、偶极-偶极三种采集装置的正反演模拟计算,从三维反演结果、剖面、电测深曲线三个维度,对比分析不同装置下断层-溶洞目标体的地电响应特征和规律。结果显示:(1) 探测深度内,温纳、施伦贝格、偶极-偶极装置可有效识别断层及其上盘三倍于电极距规模的充水溶洞,无法分辨断层下盘二倍于电极距规模的充水溶洞;(2) 相同模型和观测条件下,偶极-偶极装置对目标体的识别能力最强,其三维反演结果可识别溶洞下边界,剖面中形成左凸低阻圈闭异常,不同测深点的曲线类型、拐点、极值点与模型设计最为贴近,且拐点对应岩性界面,极值点位于地质体的中心深度。该工作对野外观测方式的选取和地质解译有一定指导意义。   相似文献   

12.
The effectiveness of inversion apparent resistivity data to determine accurately the true resistivity distribution over 2D structures has been investigated using a common inversion scheme based on smoothness-constrained nonlinear least-squares optimization with enhancing horizontal resolution (EHR) technique by numerical simulation. The theoretical model generates in RES2DMOD software at specific distance and depth using Wenner, Wenner–Schlumberger, and pole–dipole arrays were inverted. The inversion model was compared with the original 2D model in RES2DINV software. The study model includes horizontal layering, vertical resolution, and horizontal two layers with different resistivity. Also, the response to variations in data density of these arrays was investigated. The study shows the best array suitable to be used in the survey was chosen for real data acquisition at the actual site. Subsequently, the results from borehole were used to verify the results of 2D resistivity imaging method with and without EHR technique. Saturated zone (0–40 Ω-m) was found scattered at the depth of 10–20 m. The borehole is located at 63 m at 2D resistivity imaging survey which shows at depth 10–20 m is sandy silt. Highly weathered sandstone was found at 6 m depth with resistivity value of 800 Ω-m and SPT N value of 20. The bedrock was found at 27 m depth with resistivity value of 3,000 Ω-m and SPT N value of 50. The application of 2D resistivity imaging with EHR technique indicate the ability of the proposed approach in terms of density, depth, and resistivity value of anomalous and layer in a computationally and numerically efficient manner and to exhibit good performance in the data inversion.  相似文献   

13.
城市地铁修建过程中常常会遇到溶洞等不良地质条件,为更加准确探查地下溶洞的位置和大小,采用有限元法和最小二乘法正反演数值模拟手段,利用孔距、电极距和与钻孔距离三个变量构建了地下溶洞的地电模型,分析并总结了跨孔电阻率CT法对充气、充水和部分充水溶洞的电阻率响应特征及规律。结果表明:部分充水溶洞的水、气分界面明显,低阻区域和高阻区域与溶洞充水、充气部分位置大小一致,且随着溶洞充水量的增加,溶洞低电阻率响应增强,其异常范围向溶洞顶部扩大;跨孔电阻率CT法能够有效识别溶洞充填性状。   相似文献   

14.
As part of a larger regional research program “KarstEAU”, the authors have applied electrical resistivity tomography (ERT) techniques to characterize heterogeneities in the Port-Miou coastal karst aquifer (Cassis, SE France). Field surveys were carried out on intensely fractured and karstified Urgonian carbonates. Extensive research has characterized macro- and micro-scale geology of the Port-Miou area and particularly underground water-filled conduits and fault/fracture and karst systems within a former quarry. The authors applied 2D ERT along two surface profiles of length 420 and 595 m to test capability for delineating subsurface conduits and possibly relationship between conduit and fault/fracture/karst orientation; and 3D ERT with a dense 120 electrode array at 1 m spacing (11 × 10 m) was applied over an area of the quarry that had been profiled using 3D georadar and which has had intensive nearby structural geological interpretation. The 2D profiling imaged several underground conduits at depths to >50 m below ground surface and below sea level, including possibly the main Port Miou submarine spring and smaller springs. The 2D profiling within the quarry provided a better understanding of the connectivity between major fractures and faults on the quarry walls and secondary springs along the coast supporting flow of the secondary springs along interpreted fracture orientations. In addition, 2D inversion-derived conductivity models indicate that high resistivity zones above sea-level are associated with non-saturated zones and low resistivity anomalies in the non-saturated zone are associated with residual clays in paleokarsts. A partitioned lower resistivity zone below sea-level can be associated with a higher porosity/permeability zone with fractures and karstic features. Inversion models of the dense 3D ERT data indicate a higher resistivity volume within the larger surveyed block. The survey characterized the non-saturated zone and the ERT resistivities are correlated with karst features interpreted by 3D georadar and visible in the inferior wall of the quarry.  相似文献   

15.
Geoelectrical resistivity method involving vertical electrical sounding (VES) was carried out in a sedimentary environment to determine the suitability of the method for sub-surface groundwater investigations. The EC and TDS hydrochemical data in the study area clearly showed the influence of seawater intrusion. The abundance of the major cations and anions are in the following order, Na+ > Ca2+ > Mg 2+ > K+ = Cl- > HCO3- > SO42- > CO3 > NO3 > PO4. Results suggest that the groundwater in this study area is very hard and alkaline in nature. As indicated by Piper trilinear diagram, NaCl and Ca2+ - Mg2+–Cl- - SO42- facies are the dominant hydrochemical facies in the groundwater of Pearl city. The VES method by Schlamberger electrode array was applied in 12 locations, which is expected to represent the whole area. The resistivity meter (aquameter CRM 5OO) was used to collect the VES data by employing a Schlumberger electrode configuration, with half current electrode spacing (AB/2) ranging from 2 to 180 m and the potential electrode (MN) from 1 to 50 m. The resistivity data is then interpreted by WINSEV 1-D inversion program geoelectric software to entirely describe the aquifer system as well as the occurrence of groundwater. The outputs of sub-surface layers with resistivities and thickness presented in contour maps and 2-D views by using SURFER software were created. Accordingly, three zones with different resistivity values were detected, corresponding to three different formations: (1) a transition zone of sandy soil (aeolian deposits) thick formation, (2) strata’s saturated with fresh groundwater in the east disturbed by the presence of sandy shell limestone horizons, (3) a water-bearing formation in the west containing low saltwater horizons. The bedrock is encountered at an average depth of 95m. This study indicates that the groundwater reservoirs are mainly confined to the alluvial aquifer.  相似文献   

16.
选频法是音频大地电场法的进一步应用与发展。本文通过实践应用说明选频法在浅层地下水勘探中的有效性,并对选频法测深极距(MN)与地下水埋深之间的关系开展对比分析和初步理论研究。首先,采用水平交变电场、交变磁场共同作用下的均匀半空间中低阻导电球体简化地质地球物理模型,对选频法测深曲线开展正演计算;然后,对选频法在广西“十二五”农村饮水安全工程应用中的131口钻井出水量情况进行统计,并对其中98口钻井的钻探情况开展详细列表统计分析,对比研究测深曲线异常处MN极距大小与实际钻探出水深度之间的关系。理论分析与实践应用表明,选频法在浅层地下水勘探中效果明显,是一种确定浅层地下水井位的有效方法;同时,实践统计结果表明,选频法测深法异常曲线处MN极距的大小与实际钻探出水深度之间存在1∶1的近似关系,验证了理论模拟计算结果的正确性;另外,本文的研究成果表明,在浅层(<200 m)天然电磁法勘探中,天然电场观测值的大小除了与大地的电阻率、信号的频率有关外,还与电极距大小是相关的。  相似文献   

17.
In situ soil micro electrical resistivity measurements were carried out in a pilot plot within the Teaching and Research Farm of Ekiti State University with the aim of establishing relationships between such measurements, soil horizons, and textural classifications. The vertical electrical sounding (VES) technique was adopted for horizon mapping, while the horizontal profiling (HP) technique was used to determine the spatial distribution of in situ soil electrical resistivity of the topmost horizon. Twenty-five VES points were occupied with the Wenner electrode array and electrode spacing that was varied from 2 to 128 cm (0.02 to 1.28 m). The VES data were interpreted by partial curve matching and computer assisted 1-D forward modeling with the IPI2Win software. HP data were also acquired with the Wenner electrode array with a constant electrode separation of 8 cm and station interval of 1 m. Resistivity measurements were taken at 729 stations. The HP data were classified into resistivity-derived soil classes using a standard table. Eighty-one soil samples were collected from the topmost (0–3 cm) horizon and textural classification was derived from the particle size distributions. The resistivity range of values for the identified three layers was 38–590, 328–5222, and 393–900 Ω·m respectively. The average resistivities of the three layers were 263, 2554, and 703 Ω·m, with respective thicknesses of 2.85 cm, 45.52 cm, and infinite. The above resistivity regimes of the three horizons were attributed to responses from the O, A, and B soil horizons. The resistivity values of the O-horizon ranging from 210 to 750 Ω·m were classified as clayey sand while values greater than 750 Ω·m were classified as sand. The soil textural classifications obtained within the horizon were the sandy loam and loamy sand types. The cross-tabulation and spatial pattern comparison of resistivity-derived soil classes and textural classifications showed that whereas there existed some overlapping relationships, the sandy loam textural class had stronger association with the resistivity-derived clayey sand soil type, and the loamy sand textural class had stronger association with the more resistive sand soil type. This study therefore established that in situ soil electrical resistivity can be used for soil horizon mapping and textural classification.  相似文献   

18.
Self potential (SP) and electrical resistivity tomography (ERT) methods are used together with the results of groundwater samples hydrogeochemical analysis to assess the impact of the water leak from the landfill garbage site at NamSon located in Northern Hanoi on causing pollution to the surrounding environment and affecting geological structure. Selected survey area covers an area of 180 × 300 m lying in the low land of the NamSon site with a slope ranging about 8 m in direction NW–SE. There are three geophysical measurements lines denoted as T1, T2 and T3. Processing 180 SP data points has allowed to draw maps of equipotential epoch in the two periods in 2015 and 2016. The maps show four zones of SP positive anomalies with maximum amplitudes of about +20 mV where the groundwater flow direction is downward and five zones of SP negative anomalies with minimum values in a range from ?180 to ?260 mV where the groundwater flow direction is upward. Resistivity values of the subsurface layers of soils and rocks have been aquired from 2D inverse model for measuring ERT in March 2015 and March 2016. The results of the ERT allowed to define the low resistivity in the range 15–20 Ωm related to leachate plume from NamSon landfill site. Results of the physico-chemical analysis of groundwater samples from the existing six boreholes show increases in concentration of the measured pollutant parameters indicating contamination of the groundwater as a result of solid waste leachate accumulation. This result is affirmative evidence for the survey results by geophysical technique. The rapid decrease in quality of groundwater over the last year is probably due to the influence of the leachate from the NamSon landfill site.  相似文献   

19.
Electrical imaging of the groundwater aquifer at Banting,Selangor, Malaysia   总被引:1,自引:0,他引:1  
A geophysical study was carried out in the Banting area of Malaysia to delineate groundwater aquifer and marine clay layer of the alluvial Quaternary deposits of Beruas and Gula Formations. The Beruas Formation is formed by peat and clayey materials as well as silt and sands, whereas the Gula Formation consists of clay, silt, sand and gravels. Both Formations were deposited on top of the Carboniferous shale of the Kenny Hill Formation. A 2-D geoelectrical resistivity technique was used. Resistivity measurement was carried out using an ABEM SAS 4000 Terrameter. The 2-D resistivity data of subsurface material for each survey line was calculated through inverse modelling and then compared with borehole data. The resistivity images of all the subsurface material below the survey lines show similar pattern of continuous structure of layering or layers with some lenses with resistivity ranging from 0.1 to 50 Ωm. The upper layer shows resistivity values ranging from 0.1 to 10 Ωm, representing a clay horizon with a thickness up to 45 m. The second layer with depth varies from 45 to 70 m below surface and has resistivity values ranging from 10 to 30 Ωm. Borehole data indicate coarse sand with some gravels for this layer, which is also the groundwater aquifer in the study area. The lowermost layer at a depth of 70 m below ground level shows resistivity values ranging from 30–50 Ωm and can be correlated with metasedimentary rocks consisting of shale and metaquartzite.  相似文献   

20.
A combination of vertical electrical soundings (VES), 2D electrical resistivity imaging (ERI) surveys and borehole logs were conducted at Magodo, Government Reserve Area (GRA) Phase 1, Isheri, Southwestern Nigeria, with the aim of delineating the different aquifers present and assessing the groundwater safety in the area. The Schlumberger electrode array was adopted for the VES and dipole-dipole array was used for the 2D imaging. The maximum current electrode spread (AB) was 800 m and the 2D traverse range between 280 and 350 m in the east-west direction. The thickness of impermeable layer overlying the confined aquifer was used for the vulnerability ratings of the study area. Five lithological units were delineated: the topsoil, clayey sand, unconsolidated sand which is the first aquifer, a clay stratum and the sand layer that constitutes the confined aquifer horizon. The topsoil thickness varies from 0.6 to 2.6 m, while its resistivity values vary between 55.4 and 510.6 Ω/m. The clayey sand layers have resistivity values ranging from 104.2 to 143.9 Ω/m with thickness varying between 0.6 and 14.7 m. The resistivity values of the upper sandy layer range from 120.7 to 2195.2 Ω/m and thickness varies from 3.3 to 94.0 m. The resistivity of the clay layer varies from 11.3 to 96.1 Ω/m and the thickness ranges from 29.6 to 76.1 m. The resistivity value of the confined aquifer ranges between 223 and 1197.4 Ω/m. The longitudinal conductance (0.0017–0.02 mhos) assessment of the topsoil shows that the topsoil within the study area has poor overburden protective capacity, and the compacted impermeable clay layer shows that the underlying confined aquifer is well protected from contamination and can be utilized as a source of portable groundwater in the study area. This study therefore enabled the delineation of shallow aquifers, the variation of their thicknesses and presented a basis for safety assessment of groundwater potential zones in the study area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏