首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 613 毫秒
1.
The 25th April 2015 Nepal (Gorkha) earthquake has been introduced into the SCEC BBP v15.3, and validation simulations are run using EXSIM methodology with the strong ground motion data of the earthquake. Synthetic seismograms are generated along with the response spectra for engineering applications. Goodness-of-fit metrics have been computed from response spectra for 14 stations located in the Central Indo-Gangetic Plains (CIGP). Plots of residuals are made as a function of hypocentral distance for various time periods. Spatial distribution of residuals as well as average residuals for all stations for the horizontal components are computed. The results demonstrate that there was a good match between the actual data and synthetics generated by the broadband platform. Finally, four of the widely used ground motion prediction equations around the world are chosen to compare how they predict the synthetics for Gorkha earthquake in CIGP.  相似文献   

2.
A procedure to generate horizontal pairs of synthetic near‐fault ground motion components for specified earthquake source and site characteristics is presented. Some near‐fault ground motions contain a forward directivity pulse; others do not, even when the conditions for such a pulse are favorable. The proposed procedure generates pulse‐like and non‐pulse‐like motions in appropriate proportions. We use our recent stochastic models of pulse‐like and non‐pulse‐like near‐fault ground motions that are formulated in terms of physically meaningful parameters. The parameters of these models are fitted to databases of recorded pulse‐like and non‐pulse‐like motions. Using these empirical “observations,” predictive relations are developed for the model parameters in terms of the earthquake source and site characteristics (type of faulting, earthquake magnitude, depth to top of rupture plane, source‐to‐site distance, site characteristics, and directivity parameters). The correlation coefficients between the model parameters are also estimated. For a given earthquake scenario, the probability of occurrence of a directivity pulse is first computed; pulse‐like and non‐pulse‐like motions are then simulated according to the predicted proportions using the empirical predictive models. The resulting time series are realistic and reproduce important features of recorded near‐fault ground motions, including the natural variability. Moreover, the statistics of their elastic response spectra agree with those of the NGA‐West2 dataset, with the additional feature of distinguishing between pulse‐like and non‐pulse‐like cases and between forward and backward directivity scenarios. The synthetic motions can be used in addition to or in place of recorded motions in performance‐based earthquake engineering, particularly when recorded motions are scarce.  相似文献   

3.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
Evaluation of the degrees of structural damage suffered by high‐rise residential buildings after being subjected to strong ground motions is extremely important to the development of life continuity planning for building residents. However, these evaluations cannot be based on strong‐motion records alone, because earthquake observation equipment is not installed in most such buildings in Japan. In this study, we propose simple equations for estimating the stiffness degradation rate and the peak inter‐story drift ratio (PIDR) by using ambient vibration records instead of strong‐motion records when high‐rise RC buildings are subjected to a severe earthquake. More specifically, we propose one equation that relates the square root of the stiffness degradation rate, which is the ratio of natural frequencies at the maximum response to the preliminary tremor response (elastic state), in strong‐motion records with the ratio of natural frequencies identified from ambient vibrations before and after damage was suffered. We also propose an equation that relates the PIDR with the stiffness degradation rate on the basis of the stiffness‐degrading bilinear restoring force characteristic derived from the strong‐motion records of 13 high‐rise buildings for the 1995 Hyogoken‐Nanbu Earthquake (Mw 6.9) and the 2011 Tohoku‐Oki Earthquake (Mw 9.0). Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
Earthquake simulation technologies are advancing to the stage of enabling realistic simulations of past earthquakes as well as characterizations of more extreme events, thus holding promise of yielding novel insights and data for earthquake engineering. With the goal of developing confidence in the engineering applications of simulated ground motions, this paper focuses on validation of simulations for response history analysis through comparative assessments of building performance obtained using sets of recorded and simulated motions. Simulated ground motions of past earthquakes, obtained through a larger validation study of the Southern California Earthquake Center Broadband Platform, are used for the case study. Two tall buildings, a 20‐story concrete frame and a 42‐story concrete core wall building, are analyzed under comparable sets of simulated and recorded motions at increasing levels of ground motion intensity, up to structural collapse, to check for statistically significant differences between the responses to simulated and recorded motions. Spectral shape and significant duration are explicitly considered when selecting ground motions. Considered demands include story drift ratios, floor accelerations, and collapse response. These comparisons not only yield similar results in most cases but also reveal instances where certain simulated ground motions can result in biased responses. The source of bias is traced to differences in correlations of spectral values in some of the stochastic ground motion simulations. When the differences in correlations are removed, simulated and recorded motions yield comparable results. This study highlights the utility of physics‐based simulations, and particularly the Southern California Earthquake Center Broadband Platform as a useful tool for engineering applications.  相似文献   

6.
This paper investigates the seismic response of multi‐storey cross‐laminated timber (CLT) buildings and its relationship with salient ground‐motion and building characteristics. Attention is given to the effects of earthquake frequency content on the inelastic deformation demands of platform CLT walled structures. The response of a set of 60 CLT buildings of varying number of storeys and panel fragmentation levels representative of a wide range of structural configurations subjected to 1656 real earthquake records is examined. It is shown that, besides salient structural parameters like panel aspect ratio, design behaviour factor, and density of joints, the frequency content of the earthquake action as characterized by its mean period has a paramount importance on the level of nonlinear deformations attained by CLT structures. Moreover, the evolution of drifts as a function of building to ground‐motion periods ratio is different for low‐ and high‐rise buildings. Accordingly, nonlinear regression models are developed for estimating the global and interstorey drifts demands on multi‐storey CLT buildings. Finally, the significance of the results is highlighted with reference to European seismic design procedures and recent assessment proposals.  相似文献   

7.
This short communication introduces a quantitative approach for the engineering validation of ground‐motion simulations based on information theory concepts and statistical hypothesis testing. Specifically, we use the Kullback‐Leibler divergence to measure the similarity of the probability distributions of recorded and simulated ground‐motion intensity measures (IMs). We demonstrate the application of the proposed validation approach to ground‐motion simulations computed by using a variety of methods, including Graves and Pitarka hybrid broadband, the deterministic composite source model, and a stochastic white noise finite‐fault model. Ground‐motion IMs, acting as proxies for the (nonlinear) seismic response of more complex engineered systems, are considered herein to validate the considered ground‐motion simulation methods. The list of considered IMs includes both spectral‐shape and duration‐related proxies, shown to be the optimal IMs in several probabilistic seismic demand models of different structural types, within the framework of performance‐based earthquake engineering. The proposed validation exercise (1) can highlight the similarities and differences between simulated and recorded ground motions for a given simulation method and/or (2) allow the ranking of the performance of alternative simulation methods. The similarities between records and simulations should provide confidence in using the simulation method for engineering applications, while the discrepancies should help in improving the tested method for the generation of synthetic records.  相似文献   

8.
A method for generating a suite of synthetic ground motion time‐histories for specified earthquake and site characteristics defining a design scenario is presented. The method employs a parameterized stochastic model that is based on a modulated, filtered white‐noise process. The model parameters characterize the evolving intensity, predominant frequency, and bandwidth of the acceleration time‐history, and can be identified by matching the statistics of the model to the statistics of a target‐recorded accelerogram. Sample ‘observations’ of the parameters are obtained by fitting the model to a subset of the NGA database for far‐field strong ground motion records on firm ground. Using this sample, predictive equations are developed for the model parameters in terms of the faulting mechanism, earthquake magnitude, source‐to‐site distance, and the site shear‐wave velocity. For any specified set of these earthquake and site characteristics, sets of the model parameters are generated, which are in turn used in the stochastic model to generate the ensemble of synthetic ground motions. The resulting synthetic acceleration as well as corresponding velocity and displacement time‐histories capture the main features of real earthquake ground motions, including the intensity, duration, spectral content, and peak values. Furthermore, the statistics of their resulting elastic response spectra closely agree with both the median and the variability of response spectra of recorded ground motions, as reflected in the existing prediction equations based on the NGA database. The proposed method can be used in seismic design and analysis in conjunction with or instead of recorded ground motions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
This paper explores the notion of detailing reinforced concrete structural walls to develop base and mid‐height plastic hinges to better control the seismic response of tall cantilever wall buildings to strong shaking. This concept, termed here dual‐plastic hinge (DPH) concept, is used to reduce the effects of higher modes of response in high‐rise buildings. Higher modes can significantly increase the flexural demands in tall cantilever wall buildings. Lumped‐mass Euler–Bernoulli cantilevers are used to model the case‐study buildings examined in this paper. Buildings with 10, 20 and 40 stories are designed according to three different approaches: ACI‐318, Eurocode 8 and the proposed DPH concept. The buildings are designed and subjected to three‐specific historical strong near‐fault ground motions. The investigation clearly shows the dual‐hinge design concept is effective at reducing the effects of the second mode of response. An advantage of the concept is that, when combined with capacity design, it can result in relaxation of special reinforcing detailing in large portions of the walls. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Ground‐motion simulations generated from physics‐based wave propagation models are gaining increasing interest in the engineering community for their potential to inform the performance‐based design and assessment of infrastructure residing in active seismic areas. A key prerequisite before the ground‐motion simulations can be used with confidence for application in engineering domains is their comprehensive and rigorous investigation and validation. This article provides a four‐step methodology and acceptance criteria to assess the reliability of simulated ground motions of not historical events, which includes (1) the selection of a population of real records consistent with the simulated scenarios, (2) the comparison of the distribution of Intensity Measures (IMs) from the simulated records, real records, and Ground‐Motion Prediction Equations (GMPEs), (3) the comparison of the distribution of simple proxies for building response, and (4) the comparison of the distribution of Engineering Demand Parameters (EDPs) for a realistic model of a structure. Specific focus is laid on near‐field ground motions (<10km) from large earthquakes (Mw7), for which the database of real records for potential use in engineering applications is severely limited. The methodology is demonstrated through comparison of (2490) near‐field synthetic records with 5 Hz resolution generated from the Pitarka et al (2019) kinematic rupture model with a population of (38) pulse‐like near‐field real records from multiple events and, when applicable, with NGA‐W2 GMPEs. The proposed procedure provides an effective method for informing and advancing the science needed to generate realistic ground‐motion simulations, and for building confidence in their use in engineering domains.  相似文献   

12.
This paper presents an analytical study evaluating the influence of ground motion duration on structural damage of 3‐story, 9‐story, and 20‐story SAC steel moment resisting frame buildings designed for downtown Seattle, WA, USA, using pre‐Northridge codes. Two‐dimensional nonlinear finite element models of the buildings are used to estimate the damage induced by the ground motions. A set of 44 ground motions is used to study the combined effect of spectral acceleration and ground motion significant duration on drift and damage measures. In addition, 10 spectrally equivalent short‐duration shallow crustal ground motions and long‐duration subduction zone records are selected to isolate duration effect and assess its effect on the response. For each ground motion pair, incremental dynamic analyses are performed at at least 20 intensity levels and response measures such as peak interstory drift ratio and energy dissipated are tracked. These response measures are combined into two damage metrics that account for the ductility and energy dissipation. Results indicate that the duration of the ground motion influences, above all, the combined damage measures, although some effect on drift‐based response measures is also observed for larger levels of drift. These results indicate that because the current assessment methodologies do not capture the effects of ground motion duration, both performance‐based and code‐based assessment methodologies should be revised to consider damage measures that are sensitive to duration. Copyright © 2016 John Wiley & Sons, Ltd  相似文献   

13.
The purpose of this paper is to investigate the ground motion characteristics of the Chi‐Chi earthquake (21 September 1999) as well as the interpretation of structural damage due to this earthquake. Over 300 strong motion records were collected from the strong motion network of Taiwan for this earthquake. A lot of near‐field ground motion data were collected. They provide valuable information on the study of ground motion characteristics of pulse‐like near‐field ground motions as well as fault displacement. This study includes: attenuation of ground motion both in PGA and spectral amplitude, principal direction, elastic and inelastic response analysis of a SDOF system subjected to near‐field ground motion collected from this event. The distribution of spectral acceleration and spectral velocity along the Chelungpu fault is discussed. Based on the mode decomposition method the intrinsic mode function of ground acceleration of this earthquake is examined. A long‐period wave with large amplitude was observed in most of the near‐source ground acceleration. The seismic demand from the recorded near‐field ground motion is also investigated with an evaluation of seismic design criteria of Taiwan Building Code. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

14.
This study proposes a procedure for identifying spectral response curves for earthquake‐damaged areas in developing countries without seismic records. An earthquake‐damaged reinforced concrete building located in Padang, Indonesia was selected to illustrate the identification of the maximum seismic response during the 2009 West Sumatra earthquake. This paper summarizes the damage incurred by the building; the majority of the damage was observed in the third story in the span direction. The damage was quantitatively evaluated using the damage index R according to the Japanese guidelines for post‐earthquake damage evaluation. The damage index was also applied to the proposed spectral response identification method. The seismic performance of the building was evaluated by a nonlinear static analysis. The analytical results reproduced a drift concentration in the third story. The R‐index decreased with an increase in the story drift, which provided an estimation of the maximum response of the building during the earthquake. The estimation was verified via an earthquake response analysis of the building using ground acceleration data, which were simulated based on acceleration records of engineering bedrock that considered site amplification. The maximum response estimated by the R‐index was consistent with the maximum response obtained from the earthquake response analysis. Therefore, the proposed method enables the construction of spectral response curves by integrating the identification results for the maximum responses in a number of earthquake‐damaged buildings despite a lack of seismic records. Copyright © 2016 The Authors. Earthquake Engineering & Structural Dynamics published by John Wiley & Sons Ltd.  相似文献   

15.
Rupture directivity effects in ground motion are known since many years to both seismologists and earthquake engineers, i.e. in sites that are in a particular geometrical configuration with respect to the rupture, the velocity fault‐normal signals may show a large pulse which occurs at the beginning of the record and contains the most of energy. The results are waveforms different from ordinary ground motions recorded in the far field or in geometrical conditions not favorable with respect to directivity. Current attenuation laws are not able to capture such effect well, if at all, and current probabilistic seismic hazard analysis is not able to predict the resulting peculiar spectral shape. Moreover, it is believed that structures with dynamic behavior in a range of periods related to the pulse period may be subjected to underestimated seismic demand. In the paper this is investigated and increments in both elastic and inelastic seismic actions are quantified using a large dataset of records, from the next generation attenuation project (NGA), in which a fraction is comprised of velocity pulses identified in other studies. These analyses employ recently developed tools and procedures to assess directivity effects and to quantify the associated threat in terms of seismic action on structures. Subsequently, the same tools are used in one of the first attempts to identify near‐source effects in the data recorded during a normal faulting earthquake, the mainshock of the recent Abruzzo (central Italy) sequence, leading to conclude that pulse‐like effects are likely to have occurred in the event, that is (1) observation of pulse‐like records in some near‐source stations is in fair agreement with existing predictive models, (2) the increment in seismic demand shown by pulse‐like ground motion components complies with the results of the analysis of the NGA data, and (3) seismic demand in non‐impulsive recordings is generally similar to what expected for ordinary records. The results may be useful as a benchmark for inclusion of near‐source effect in design values of seismic action and structural risk analysis. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
This paper addresses two important issues of concern to practicing engineers and researchers alike in application of performance‐based seismic assessment (PBSA) methodology on buildings: (i) the number of ground motion records required to exercise PBSA—current practice (FEMA P‐58‐1) requires eleven or more pairs of motions for this purpose, and (ii) the time and effort associated with performing the number of nonlinear response history analyses required to exercise PBSA. We present a method for exercising of PBSA that employs classical linear modal analysis to develop a first estimate (i.e., a priori) of probability distribution of loss, followed by utilizing Bayesian statistics to update this estimate using estimates of loss obtained by utilizing a small number of nonlinear response history analyses of a detailed model of the building (i.e., posterior). The proposed technique is used to assess the distribution of monetary loss of two case studies, a 4‐story reinforced concrete moment‐resisting frame building and a 20‐story steel moment‐resisting frame building, both located in Los Angeles, for a ground motion hazard with 10% probability of exceedance in 50 years. The efficiency of the proposed PBSA method is demonstrated by showing the similarity between the distribution of monetary loss at each story of case study buildings obtained from the traditional/sophisticated PBSA methodology and the proposed PBSA method in this study. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The 2015 Illapel earthquake produced self‐evacuation of tall buildings in the city of Buenos Aires, Argentina, located 1280 km away from the epicenter. The ground motions in Buenos Aires due to the main event (Mw 8.3) and its aftershocks were registered by a new seismometer. The data collected allowed to estimate the maximum story drift ratios and top floor accelerations for tall buildings in Buenos Aires. The similarities between the response spectra and the Fourier amplitude spectra for the mainshock and its aftershocks show the influence that the dynamic properties of the 300‐m soil deposit have on the large acceleration amplification produced in these groups of buildings.  相似文献   

18.
This study presents results from shake table experiments of a wood‐frame building conducted at the University of California, Berkeley. A 13.5‐ft × 19.5‐ft two‐story wood‐frame building representing San Francisco 1940s design of a residential building with a garage space on the first story (house‐over‐garage) was tested. The test building was subjected to scaled ground motion based on Los Gatos record from Loma Prieta 1989 earthquake. The strong motion time history was scaled to match design spectra of a site in Richmond district of San Francisco. The test results demonstrated the seismic vulnerability of the test building due to soft story mechanism and significant twisting when shaken in two horizontal directions. In addition to conventional instrumentation for measuring acceleration and position of selected points of the test building, high‐definition laser scanning technology was employed to assess global and local anomalies of the building after the shake table tests. The analysis conducted in this study showed very good correlation between conventional data recorded from position transducers and the laser scans. These laser scans expanded limits of conventional data at discrete points and allowed analyzing the whole building after shaking. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
This paper focuses on the effects of long‐period pulse of near‐fault ground motions on the structural damage potential. Two sets of near‐fault ground motion records from Chi‐Chi, Taiwan earthquake and Northridge earthquake with and without distinct pulse are selected as the input, and the correlation analysis between 30 non‐structure‐specific intensity measure parameters and maximum inelastic displacements and energy responses (input energy and hysteretic energy) of bilinear single degree of freedom systems are conducted. Based on the frequency characteristic of near‐fault ground motions with remarkable long‐period components, two intensity indices are proposed, namely, the improved effective peak acceleration (IEPA) and improved effective peak velocity (IEPV). In addition a new characteristic period of these ground motions is defined based on IEPA and IEPV. Numerical results illustrate that the intensity measure parameters related to ground acceleration present the best correlation with the seismic responses for rigid systems; the velocity‐related and displacement‐related parameters are better for medium‐frequency systems and flexible systems, respectively. The correlation curves of near‐fault ground motions with velocity pulse differ from those of ground motions without pulse. Moreover, the improved parameters IEPA and IEPV of near‐fault impulsive ground motions enhance the performance of intensity measure of corresponding conventional parameters, i.e. EPA and EPV. The new characteristic period based on IEPA and IEPV can better reflect the frequency content of near‐fault ground motions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
The study presented in this paper addresses the issue of engineering validation of Graves and Pitarka's (2010) hybrid broadband ground motion simulation methodology with respect to some well‐recorded historical events and considering the response of multiple degrees of freedom (MDoF) systems. Herein, validation encompasses detailed assessment of how similar is, for a given event, the seismic response due to comparable hybrid broadband simulated records and real records. In the first part of this study, in order to investigate the dynamic response of a wide range of buildings, MDoF structures are modeled as elastic continuum systems consisting of a combination of a flexural cantilever beam coupled with a shear cantilever beam. A number of such continuum systems are selected including the following: (1) 16 oscillation periods between 0.1 and 6 s; (2) three shear to flexural deformation ratios to represent respectively shear‐wall structures, dual systems, and moment‐resisting frames; and (3) two stiffness distributions along the height of the systems, that is, uniform and linear. Demand spectra in terms of generalized maximum interstory drift ratio (IDR) and peak floor acceleration (PFA) are derived using simulations and actual recordings for four historical earthquakes, namely, the 1979 Mw 6.5 Imperial Valley earthquake, 1989 Mw 6.8 Loma Prieta earthquake, 1992 Mw 7.2 Landers earthquake, and 1994 Mw 6.7 Northridge earthquake. In the second part, for two nonlinear case study structures, the IDR and PFA distributions over the height and their statistics, are obtained and compared for both recorded and simulated time histories. These structures are steel moment frames designed for high seismic hazard, 20‐story high‐rise and 6‐story low‐rise buildings. The results from this study highlight the similarities and differences between simulated and real records in terms of median and intra‐event standard deviation of logs of seismic demands for MDoF building systems. This general agreement, in a broad range of moderate and long periods, may provide confidence in the use of the simulation methodology for engineering applications, whereas the discrepancies, statistically significant only at short periods, may help in addressing improvements in generation of synthetic records. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号