首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
On March 1993 an earthquake of magnitude Ms = 5·5 shook Pyrgos, a town in Western Peloponnissos, one of the most seismic prone areas in Greece. The damage induced to modern reinforced concrete buildings was rather light in contrast to the damage induced to historic and traditional buildings of adobe, stone or brick masonry which was severe. In order to study the causes of structural damage, detailed data are collected from a rather large statistical sample of 1023 masonry buildings and 22 reinforced concrete framed buildings with visible damage. For each building the number of storeys, the material of construction, as well as the type and the degree of damage are recorded. In addition, consideration is given to the site of the building within the town and the corresponding soil conditions. For reinforced concrete buildings, damage occured mostly in areas with relatively high estimated spectral accelerations and fundamental soil periods of vibration close to those of the buildings. Nevertheless, further analysis is required to explain the selective damage of a very small number of buildings. For masonry houses, the effect of soil conditions is more systematic. Moreover, the effects of the number of storeys as well as the age and material of construction appear to be dominant.  相似文献   

2.
Bangkok, the capital city of Thailand, is located at a remote distance from seismic sources. However, it has a substantial risk from these distant earthquakes due to the ability of the underlying soft clay to amplify ground motions. It is therefore imperative to conduct a detailed seismic hazard assessment of the area. Seismic microzonation of big cities, like Bangkok, provides a basis for site‐specific hazard analysis, which can assist in systematic earthquake mitigation programs. In this study, a seismic microzonation map for the greater Bangkok area is constructed using microtremor observations. Microtremor observations were carried out at more than 150 sites in the greater Bangkok area. The predominant periods of the ground were determined from the horizontal‐to‐vertical (H/V) spectral ratio technique. A microzonation map was then developed for the greater Bangkok area based on the observations. Moreover, the transfer functions were calculated for the soil profile at eight sites, using the computer program SHAKE91, to validate the results from the microtremor analysis. The areas near the Gulf of Thailand, underlaid by a thick soft clay layer, were found to have long natural periods ranging from 0.8s to 1.2s. However, the areas outside the lower central plain have shorter predominant periods of less than 0.4s. The study shows that there is a great possibility of long‐period ground vibration in Bangkok, especially in the areas near the Gulf of Thailand. This may have severe effects on long‐period structures, such as high‐rise buildings and long‐span bridges. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
Microtremor Measurements for the Microzonation of Dinar   总被引:3,自引:0,他引:3  
v--vThe geotechnical site conditions in Dinar town located in western Turkey were investigated after the 1995 Dinar earthquake based on borings, in situ penetration tests, seismic wave velocity measurements, and microtremor records. The variation of damage distribution within the town was evaluated with respect to 23 district damage ratios calculated, based on the detailed damage survey conducted by the General Directorate of Disaster Affairs. Site amplifications were estimated from microtremor spectral ratios and microzonation was performed using a GIS methodology. The results of in situ penetration tests and seismic wave velocity measurements as well as the damage distribution were compared with the amplification zonation obtained from microtremor records. The results indicate the applicability of microtremor spectral ratios for assessing the local site conditions and site amplifications.  相似文献   

4.
Building period formulas in seismic design code are evaluated with over 800 apparent building periods from 191 building stations and 67 earthquake events. The evaluation is carried out with the formulas in ASCE 7‐05 for steel and RC moment‐resisting frames, shear wall buildings, braced frames, and other structural types. Qualitative comparison of measured periods and periods calculated from the code formulas shows that the formula for steel moment‐resisting frames generally predicts well the lower bound of the measured periods for all building heights. But the differences between the periods from code formula and measured periods of low‐ to‐medium rise buildings are relatively high. In addition, the periods of essential buildings designed with the importance factor are about 40% shorter than the periods of non‐essential buildings. The code formula for RC moment‐resisting frames describes well the lower bound of measured periods. The formula for braced frames accurately predicts the lower bound periods of low‐to‐medium rise buildings. The formula for shear wall buildings overestimates periods for all building heights. For buildings that are classified as other structural types, the measured building periods can be much shorter than the periods calculated with the code formula. Based on these observations, it is suggested to use Cr factor of 0.015 for shear walls and other structural types. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A comprehensive parametric study on the inelastic seismic response of seismically isolated RC frame buildings, designed for gravity loads only, is presented. Four building prototypes, with 23 m × 10 m floor plan dimensions and number of storeys ranging from 2 to 8, are considered. All the buildings present internal resistant frames in one direction only, identified as the strong direction of the building. In the orthogonal weak direction, the buildings present outer resistant frames only, with infilled masonry panels. This structural configuration is typical of many existing RC buildings, realized in Italy and other European countries in the 60s and 70s. The parametric study is based on the results of extensive nonlinear response‐time history analyses of 2‐DOF systems, using a set of seven artificial and natural seismic ground motions. In the parametric study, buildings with strength ratio (Fy/W) ranging from 0.03 to 0.15 and post‐yield stiffness ratio ranging from 0% to 6% are examined. Three different types of isolation systems are considered, that is, high damping rubber bearings, lead rubber bearings and friction pendulum bearings. The isolation systems have been designed accepting the occurrence of plastic hinges in the superstructure during the design earthquake. The nonlinear response‐time history analyses results show that structures with seismic isolation experience fewer inelastic cycles compared with fixed‐base structures. As a consequence, although limited plastic deformations can be accepted, the collapse limit state of seismically isolated structures should be based on the lateral capacity of the superstructure without significant reliance on its inherent hysteretic damping or ductility capacity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
During the Mw=6.9 January 1, 1980 earthquake in the Azores, the damage distribution in the town of Angra do Heroísmo, in Terceira Island, had a non-homogeneous spatial character. In order to understand the observed pattern of damage a microtremor survey was carried out, using ambient vibrations, and the data were analysed with the J-Sesame software, following the H/V Nakamura methodology. The results are in good agreement with the surface geology and they show a good correlation with the observed damages. Two building surveys were performed, in 1980 on damage evaluation and in 2000 on characterization of few building parameters. With all these elements (surface geology type, soil peak frequency, building type, number of stories and damage level) for 2111 buildings it was possible to perform several interparameter analysis, which enabled the identification of indicators that could be used to improve the damage estimation for future events.  相似文献   

7.
丽江大研镇震灾分布和地脉动测量结果之间的相关性   总被引:4,自引:2,他引:4  
蒋乐群  李康龙 《地震研究》1997,20(1):125-131
丽江7.0级地震后,大研镇被毁建筑物的地理分布呈显4条条带,伤亡人员的地理分布和上述条带重合。91个短周期地脉动测点的观测资料表明,分布在上述条带内的大多数测点,其卓越周期大于0.3S;条带外的测点,其卓越周期一般在0.1S左右。作认为卓越周期和烈度异常之间良好的相关性,是因为地脉动卓越周期和地方震的频谱之间存在良好的相关性。  相似文献   

8.
—?In Almería city large earthquakes occurred and many buildings were completely destroyed in these historical earthquakes. The actual population of Almería city is about 200,000 people. This population is rapidly increasing and new urbanizing areas are growing to the eastern part of the city where they are located in softer soil conditions. Consequently, the evaluation of surface soil conditions is very important from a standpoint of earthquake disaster mitigation. We have obtained a landform classification map developed by analysing aerial photos, large-scale topographic maps and 80 borehole data. Eleven unit areas, which have different soil conditions, were inferred from this research. Also, S-wave velocity prospecting tests were carried out at several sites within the city. The shear-velocity values of the ground vary from 1689?m/s in hard rock to 298?m/s in soft soil. These results are useful for understanding the uppermost soil characteristics and are used for soil classification. Finally, short-period microtremor observations were densely carried out in the research area and NAKAMURA's method (1989) was applied for determining predominant periods. Microtremors were observed at about 173 sites with mainly 400?m interval in rock sites and 200?m interval in relatively soft soil sites. From the result of these microtremor measurements, the predominant period determined at rock site, in the western part of the city and historic area, is very short, about 0.1?s, and very stable. However at soft soil sites, in the center of the city, near Zapillo Beach and in the newly developed urban area, the predominant period is about 1.0?s and even larger in concordance with the geological conditions. Finally, at medium soil sites, in the eastern part of the city, the predominant period is about 0.4?s and it appears very stable in the whole region. The difference of predominant periods between hard rock and soft soil sites is very clear and it has been observed that the distribution of predominant periods depends heavily on the surface soil conditions.  相似文献   

9.
We have tried to estimate the yield shear strengths of reinforced concrete (RC) buildings based on the damage statistics in Kobe surveyed after the Hyogo‐ken Nanbu, Japan, earthquake of 1995 and the non‐linear response analyses for synthetic waveforms calculated from a complex seismic source and a three‐dimensional basin structure. First, a set of building models that represented the RC building stock in Kobe was constructed and plausible non‐linear multi‐degree‐of‐freedom models with four different numbers of stories were created based on the current seismic code and construction practice. For response analysis the damage criterion and the strength distribution should be assumed a priori. When the damage ratios for these standard models were calculated it was found that the damage ratios were so high that we had to increase the average yield strengths in order to match the calculated damage ratios to those observed. After searching the best models it was found that the estimated average yield strengths should be much higher than those based on the code, especially for low‐rise buildings. Using this set of building models we succeeded in reproducing the belt‐shaped area with high damage ratios in Kobe. One can apply the proposed methodology to different countries if there is enough damage data, strong motion records, and building statistics. If there is sparse damage data at several locations only, then our models can be adjusted to reproduce observed damage data and used for damage prediction as a first‐order approximation. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

10.
An earthquake with a magnitude of 5.7 $(\text{ M}_{\mathrm{L}})$ has struck Simav, Kutahya located in the western part of Turkey on May 19, 2011. The ground motion caused observable damage within 25 km radius from the epicenter. Although the earthquake is moderate, its effects on the structures are serious. This paper presents the observations on seismic damages of reinforced concrete (RC) and masonry structures. Common reasons of damage in RC buildings are: low quality of concrete, detailing mistakes of reinforcement, short column, pounding, overhangs and misconstructed gable and outer infill wall parts. Interesting cases related to these deficiencies are reported. Damages in the masonry buildings are due to lack of connection between orthogonal walls and unsuitable location and dimension of openings. The damages at structures are more noticeable at regions with unfavorable soil conditions like plain regions or foothills. However, on stiffer soils at hilly sides, the damages seem to be more limited and masonry structures are observed to be less affected compared to the RC ones. The damages in RC buildings found to be increasing with story number for light damage states. However, for heavier damage states, 4–5 story buildings are observed to be the most damaged.  相似文献   

11.
2012 Emilia earthquake,Italy: reinforced concrete buildings response   总被引:1,自引:1,他引:0  
Data of the Italian National Institute of Statistics are collected aimed at characterizing Reinforced Concrete (RC) building stock of the area struck by the 2012 Emilia earthquake (number of storeys, age of construction, structural typology). Damage observations, collected right after the event in reconnaissance reports, are shown and analyzed emphasizing typical weaknesses of RC buildings in the area. The evolution of seismic classification for Emilia region and RC buildings’ main characteristics represent the input data for the assessment of non-structural damage of infilled RC buildings, through a simplified approach (FAST method), based on EMS-98 damage scale. Peak Ground Acceleration (PGA) capacities for the first three damage states of EMS-98 are compared with registered PGA in the epicentral area. Observed damage and damage states evaluated for the PGA of the event, in the epicentral area, are finally compared. The comparison led to a fair agreement between observed and numerical data.  相似文献   

12.
The authors apply soil response estimation techniques employing accelerograms for fifteen earthquakes recorded at the Yokohama Strong Motion Network and its vertical array of nine sites, plus microtremor data recorded at all 150 sites. Assessment of the reliability of surface to reference site spectral ratios, and horizontal to vertical spectral ratios of S‐waves, coda, and microtremors, relied on cross‐validation with both surface to borehole spectral ratios, and theoretical soil response functions for vertically incident SH plane waves calculated from the vertical array recordings and logging data, respectively. The results indicate the following: (1) the reference site method provides more accurate soil response estimations; (2) the H/V of microtremors provides relatively better soil response estimations than its S‐wave and coda counterparts; and (3) the H/V of microtremors provides coincident soil response estimations at two‐thirds of the sites when considering no more than ±30% mismatch in the determination of the predominant periods. The matching of parameters obtained from the analysis of microtremors, combined with their relatively low economic cost and the possibility of recording without strict spatial or time restrictions turns microtremors into a particularly appealing approach. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

13.
The results of experimental tests carried out on reinforced concrete (RC) full‐scale 2‐storey 2‐bays framed buildings are presented. The unretrofitted frame was designed for gravity loads only and without seismic details; such frame was assumed as a benchmark system in this study. A similar RC frame was retrofitted with buckling‐restrained braces (BRBs). The earthquake structural performance of both prototypes was investigated experimentally using displacement‐controlled pushover static and cyclic lateral loads. Modal response properties of the prototypes were also determined before and after the occurrence of structural damage. The results of the dynamic response analyses were utilized to assess the existing design rules for the estimation of the elastic and inelastic period of vibrations. Similarly, the values of equivalent damping were compared with code‐base relationships. It was found that the existing formulations need major revisions when they are used to predict the structural response of as‐built RC framed buildings. The equivalent damping ratio ξeq was augmented by more than 50% when the BRBs was employed as bracing system. For the retrofitted frame, the overstrength Ω and the ductility µ are 1.6 and 4.1, respectively; the estimated R‐factor is 6.5. The use of BRBs is thus a viable means to enhance efficiently the lateral stiffness and strength, the energy absorption and dissipation capacity of the existing RC substandard frame buildings. The foundation systems and the existing members of the superstructure are generally not overstressed as the seismic demand imposed on them can be controlled by the axial stiffness and the yielding force of the BRBs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents a study of the ambient seismic noise features in Motril City. The predominant resonant period at each site was determined using the Horizontal to Vertical Noise Ratio (HVNR) of the microtremors records; it was applied to 91 points which cover the city and we present the distribution of the periods over a map which shows important characteristics requiring consideration in a study focussing on the mitigation of the seismic risk. Using these results, two zones can be distinguished: north of the GG profile with predominant periods smaller than 0.25 sec which corresponds with a hard soil, and south of GG with periods ranging from 0.25 to 0.6 indicating a medium-soft soil. Microtremors are a preliminary useful tool that compensates for the lack of seismic recorded data, and that can complement other valuable information (borehole logs, geology, etc.) to evaluate the seismic risk on places as Motril City where some of this information is unavailable. Through the predominant period the HVNR indicates the kind of soil we are dealing with.  相似文献   

15.
In a seismically active region, structures may be subjected to multiple earthquakes, due to mainshock–aftershock phenomena or other sequences, leaving no time for repair or retrofit between the events. This study quantifies the aftershock vulnerability of four modern ductile reinforced concrete (RC) framed buildings in California by conducting incremental dynamic analysis of nonlinear MDOF analytical models. Based on the nonlinear dynamic analysis results, collapse and damage fragility curves are generated for intact and damaged buildings. If the building is not severely damaged in the mainshock, its collapse capacity is unaffected in the aftershock. However, if the building is extensively damaged in the mainshock, there is a significant reduction in its collapse capacity in the aftershock. For example, if an RC frame experiences 4% or more interstory drift in the mainshock, the median capacity to resist aftershock shaking is reduced by about 40%. The study also evaluates the effectiveness of different measures of physical damage observed in the mainshock‐damaged buildings for predicting the reduction in collapse capacity of the damaged building in subsequent aftershocks. These physical damage indicators for the building are chosen such that they quantify the qualitative red tagging (unsafe for occupation) criteria employed in post‐earthquake evaluation of RC frames. The results indicated that damage indicators related to the drift experienced by the damaged building best predicted the reduced aftershock collapse capacities for these ductile structures. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
When performing the seismic risk assessment of new or existing buildings, the definition of compact indexes able to measure the damaging and safety level of structures is essential, also in view of the economic considerations on buildings rehabilitation. This paper proposes two series of indexes, named, respectively, Global Damage Indexes (GDIs), which are representative of the overall structure performance, and Section Damage Indexes (SDIs), which assess the conditions of reinforced concrete (RC) beam‐column sections. Such indexes are evaluated by means of an efficient numerical model able to perform nonlinear analyses of the RC frame, based on the continuum damage mechanics theory and fiber approach. An improvement of a two‐parameter damage model for concrete, developed by some of the authors, which guarantees a better correlation between the Local Damage Indexes (LDIs) and the material's mechanical characteristics, is also presented. For the reinforcement, a specific LDI, named ‘steel damage index’, which takes into account the plastic strain development and the bar buckling effect, is proposed. The numerical model has been employed to simulate several experimental tests, in order to verify the accuracy of the proposed approach in predicting the RC member's behavior. Nonlinear static and dynamic analyses of two RC frames are carried out. The robustness of the method, as well as the effectiveness of the GDIs in assessing the structural conditions, are demonstrated here. Finally, comparisons between the evolution of GDIs and the achievement of the performance levels as proposed in FEMA 356 are reported. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A practical method is presented for determining three‐dimensional S‐wave velocity (VS) profile from microtremor measurements. Frequency–wave number (fk) spectral analyses of microtremor array records are combined, for this purpose, with microtremor horizontal‐to‐vertical (H/V) spectral ratio techniques. To demonstrate the effectiveness of the proposed method, microtremor measurements using arrays of sensors were conducted at six sites in the city of Kushiro, Japan. The spectral analyses of the array records yield dispersion characteristics of Rayleigh waves and H/V spectra of surface waves, and joint inversion of these data results in VS profiles down to bedrock at the sites. Conventional microtremor measurements were performed at 230 stations within Kushiro city, resulting in the H/V spectra within the city. Three‐dimensional VS structure is then estimated from inversion of the H/V spectra with the VS values determined from the microtremor array data. This reveals three‐dimensional VS profile of Kushiro city, together with an unknown hidden valley that crosses the central part of the city. The estimated VS profile is consistent with available velocity logs and results of subsequent borings, indicating the effectiveness of the proposed method. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
This study presents a seismic fragility analysis of low‐rise masonry in‐filled (MI) reinforced concrete (RC) buildings using a proposed coefficient‐based spectral acceleration method. The coefficient‐based method, without requiring any complicated finite element analysis, is a simplified procedure for assessing the spectral acceleration demand (or capacity) of buildings subjected to earthquakes. This paper begins with a calibration of the proposed coefficient‐based method for low‐rise MI RC buildings using published experimental results obtained from shaking table tests. Spectral acceleration‐based fragility curves for low‐rise MI RC buildings under various inter‐story drift limits are then constructed using the calibrated coefficient‐based method. A comparison of the experimental and estimated results indicates that the simplified coefficient‐based method can provide good approximations of the spectral accelerations at peak loads of low‐rise MI RC buildings, if a proper set of drift‐related factors and initial fundamental periods of structures are used. Moreover, the fragility curves constructed using the coefficient‐based method can provide a satisfactory vulnerability evaluation for low‐rise MI RC buildings under a given performance level. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
An Ms ~ 6 earthquake, originating at a normal fault directly underneath the town of Kalamata, caused substantial structural damage to reinforced-concrete and masonry buildings, to contemporary as well as centuries-old churches, and to a major harbour quaywall. Two accelerograms were recorded on stiff alluvial deposits. The seismologic and engineering facts of the earthquake are presented in the first half of the paper. Particular attention is paid to the non-uniform pattern of damage distribution, at both regional and local scale. The second half of the paper investigates the possible role of the ‘local soil conditions’ and of the ‘mechanics of the source’ in the observed pattern of damage and in the amplitude and frequency composition of the two records. To this end, numerical modelling of site-specific motions is attempted using state-of-practice methods, and utilizing the results of an extensive geotechnical exploration programme. It is concluded that substantial evidence does exist indicating that both soil and source effects have contributed to the non-uniform spatial distribution of damage. The effect of through-soil ‘filtering’ of the seismic waves appears most evident in the coastal neighbourhoods of the town, where the underlying loose saturated silty sands in the over-50 m-deep soil deposit may have played a beneficial role in weakening the ground-surface shaking; the structural damage in these areas was insignificant. Qualitative arguments are also put forward for explaining some aspects of the observed pattern of damage in terms of fault orientation and ‘directivity’ effects.  相似文献   

20.
A new formulation is proposed to model pounding between two adjacent structures, with natural periods T1 and T2 and damping ratios ζ1 and ζ2 under harmonic earthquake excitation, as non‐linear Hertzian impact between two single‐degree‐of‐freedom oscillators. For the case of rigid impacts, a special case of our analytical solution has been given by Davis (‘Pounding of buildings modelled by an impact oscillator’ Earthquake Engineering and Structural Dynamics, 1992; 21 :253–274) for an oscillator pounding on a stationary barrier. Our analytical predictions for rigid impacts agree qualitatively with our numerical simulations for non‐rigid impacts. When the difference in natural periods between the two oscillators increases, the impact velocity also increases drastically. The impact velocity spectrum is, however, relatively insensitive to the standoff distance. The maximum relative impact velocity of the coupled system can occur at an excitation period Tn* which is either between those of the two oscillators or less than both of them, depending on the ratios T1/T2 and ζ1/ζ2. Although the pounding force between two oscillators has been primarily modelled by the Hertz contact law, parametric studies show that the maximum relative impact velocity is not very sensitive to changes in the contact parameters. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号