首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The simplified mechanical method POST (PushOver on Shear Type models) for seismic vulnerability assessment of RC buildings is used in this study to derive damage scenarios for a database of 7597 RC buildings subjected to the 2009 L’Aquila earthquake. POST allows the evaluation of fragility curves through the determination of the non-linear static response of RC buildings in closed form, assuming the hypothesis of shear type behaviour, and considering the influence of infill panels both in the derivation of structural response and in assessment of building damage, which is defined according to the European Macroseismic Scale EMS-98. The aim of the present study is to provide a much more significant and reliable validation of the methodology, thanks to a much wider database compared to previous studies, and based on a different application of the methodology, i.e. at building class-level instead of single building-level. To this aim, the main geometrical-typological characteristics of the analysed buildings (number of storeys, age of construction, building area) have been statistically characterized based on data collected from post-earthquake AeDES survey forms, considering both the variability of each single parameter and the correlation that exists between one parameter and the other. This also allows to analyse the effectiveness of the adopted analytical procedure in predicting the general trends of observed damage with these parameters, showing a good agreement between observed and predicted trends. The overall predicted damage scenarios are compared with the corresponding observed ones, collected from AeDES survey forms, highlighting, again, a good agreement. Finally, the assumed mechanical interpretation of damage classification of EMS-98 is validated through the comparison between the distributions of damage to vertical structures and infill panels and the corresponding observed post-earthquake damage data.  相似文献   

2.
On August 21st, 2017, an earthquake with duration magnitude Md?=?4.0 and epicentre in Casamicciola Terme hit Ischia island, in the South of Italy. This event caused two fatalities and dozens of injured people. Moreover, despite the low magnitude, the earthquake produced significant damages to masonry and reinforced concrete (RC) buildings, with some partial or complete collapse of structures, in a very limited area close to the epicentre, while even at small distance from the most damaged zone the earthquake was just felt by local people and tourists. In the days after the event, discussions concerning the destructive effects of such an earthquake arose in the scientific community—as also reported by local and national media. In this paper, the seismic history of Ischia island is recalled to show and explain the peculiarity of the August 21st earthquake, which is also described in terms of ground motion and response spectra characteristics. The results of the first surveys carried out in Casamicciola Terme are reported, together with appropriate pictures, to introduce and explain the observed damage state of masonry and RC buildings in the epicentral zone. Then, data from the 15th general census of the population and dwellings (ISTAT) is used to define vulnerability classes according to the classification of the European Macrosismic Scale (EMS-98) (Grünthal, 1998). Seismic damage scenarios are then evaluated combining macro-seismic intensity values obtained using an interpolation method starting from QUEST macro-seismic survey data (Azzaro et al., 2017 ) and fragility curves for A-to-D vulnerability classes and for five damage states, from DS0 (no damage) to DS5 (collapse) trough a Monte Carlo simulation technique. The distributions of Usable, Temporarily or Partially Unusable, and Unusable buildings, which are obtained by using relationships between damage and usability judgments obtained through post-earthquake damage data collected after past seismic events, result in very good accordance with those published in September 1st, 2017 by the Department of Civil Protection, regarding a dataset of about 600 buildings.  相似文献   

3.
A damage scenario based on observational data collected in L’Aquila Municipality after the 6th April 2009 earthquake is compared with a predicted damage scenario derived from the application of a simplified analytical method for seismic vulnerability assessment of Reinforced Concrete (RC) buildings at large scale. The observational damage scenario is derived from a database of 131 RC buildings located in the Municipality of L’Aquila, which after the 2009 earthquake were subjected to post-earthquake usability assessment procedure. The simplified analytical approach adopted is based on the Capacity Spectrum Method to evaluate seismic capacity at different Damage States (DSs) based on the displacement capacity of structural and non-structural elements. DSs and the corresponding displacement capacity are defined through the interpretation of the observational-based DSs provided by the European Macroseismic Scale EMS-98. Data predicted by the adopted methodology are in good agreement with the observed damage distribution. The observed damage scenario is also compared with predicted scenarios derived from other methodologies from literature.  相似文献   

4.
On May 11, 2011 an earthquake of magnitude 5.1 ( \(M_{w}\) ) struck Murcia region causing nine casualties and damage to buildings and infrastructures. Even if the main characteristics of the event would classify it as a moderate earthquake, the maximum Peak Ground Acceleration (PGA) registered (equal to 0.37 g) exceeded significantly local code provisions in terms of hazard at the site. This high PGA was a result of directivity effects in the near source region. An overview of earthquake characteristics and damage observed is provided. Notwithstanding the lack of proper structural design characterizing building stock in the area, most of the losses were caused by non-structural damage. According to in field observations, it emerges that masonry infills provided additional, “not designed”, strength to reinforced concrete (RC) buildings. Observed damage data, collected after the earthquake, are shown and compared to the results of a simplified approach for nonstructural damage assessment of RC infilled structures (FAST vulnerability approach). The latter comparison provided a fair accordance between observed data and analytical results.  相似文献   

5.
The earthquake of June 20, 1978 (M6.5) near Thessaloniki, Greece, and the abundant information on damage distribution provided researchers with an opportunity for a more detailed study of earthquake effects. The damage on buildings caused by that earthquake was recorded in several ways. In this paper two of them will be presented and discussed: First, the use of questionnaires filled in by citizens and second, the in situ inspection of the buildings by a team of expert engineers, enriched by data of retrofitting costs, where available. In the current study, the damage data derived from the questionnaires are compared against the ones given by the engineers after they have been both converted to the European Macroseismic Scale 1998 (EMS-98) Damage Grades. It is observed that for EMS-98 damage grades equal and larger than 2 the questionnaire method overestimates damage while for lower grades both approaches provide comparable results.  相似文献   

6.
The great historical 1755 earthquake. Effects and damage in Spain   总被引:3,自引:2,他引:3  
The access to the complete reports sent in answer of a Royal enquire relative to the 1755 earthquake (Archivo Historico Nacional, 1756) provided us with information more comprehensive than that included in the analysis of such documents prepared by the Spanish Royal Academy of History in 1756 (Real Academia de la Historia, 1756). With such data, we have made a new study of the shock centred mainly in the following points: number of victims, source parameters (including moment magnitude and epicentral location),intensity map and seismogeological effects compared with those expected from the EMS-98. Relevant results from this analysis are: a new intensity attenuation law for earthquakes from the region of the 1755 shocks and first approximation damage probability matrices for buildings of the types common in the XVII to XIX centuries affected by large, distant earthquakes.  相似文献   

7.
2017年5月11日新疆塔什库尔干5.5级地震给震区建筑结构造成了不同程度破坏。选择震区钢筋混凝土(RC)框架结构、砖混结构以及土石木结构等3类典型建筑结构,介绍了各类建筑结构地震破坏特点,分析了震害特征与破坏机理。结果表明:RC框架结构在地震中表现出了优异的抗震性能,即使在震中区,破坏也仅仅表现为非结构性破坏,如填充墙开裂和吊顶脱落等;砖混结构绝大多数抗震性能优良,仅震中区的少数建筑物发生了承重墙墙体开裂情况;土石木结构房屋抗震性能最差,地震破坏最为严重,是导致该次地震人员伤亡主要原因。建议地震高烈度设防区房屋建筑应采用抗震性能较好的RC框架结构和砖混结构,而抗震性能差的土石木建筑房屋应尽量避免继续建设和使用。结果可供类似地区房屋建设和建筑结构抗震设计等工作参考。  相似文献   

8.
This preliminary study aims to investigate a M w 6.3 earthquake that occurred in South Iceland on Thursday 29 May 2008 at 15:45 UTC. The epicentre was in the Olfus District between the towns of Selfoss and Hveragerdi. This study examines the data recorded and the damage observed immediately after the event. Horizontal accelerations of up to 80%g were recorded in the epicentral region and there is visual evidence that the vertical acceleration exceeded 1 g. The PGA data is compared to a ground motion estimation model developed for the South Iceland earthquakes in June 2000. In general the basic properties of this event are found to be similar to the characteristics of the South Iceland earthquakes in June 2000. The duration of strong-motion is short and the intensity attenuates rapidly with increasing distance. The earthquake action resisted by buildings in the near fault area is inspected through evaluation of elastic as well as inelastic response spectra. The vast majority of structures seemed to withstand the strong-motion fairly competently and without significant visual damage due firstly to the low-rise, predominantly reinforced concrete or timber, style of buildings. Secondly, the short duration of strong-motion contributed to the endurance of structures.  相似文献   

9.
A comprehensive study is presented for empirical seismic vulnerability assessment of typical structural types, representative of the building stock of Southern Europe, based on a large set of damage statistics. The observational database was obtained from post-earthquake surveys carried out in the area struck by the September 7, 1999 Athens earthquake. After analysis of the collected observational data, a unified damage database has been created which comprises 180,945 damaged buildings from/after the near-field area of the earthquake. The damaged buildings are classified in specific structural types, according to the materials, seismic codes and construction techniques in Southern Europe. The seismic demand is described in terms of both the regional macroseismic intensity and the ratio αg/ao, where αg is the maximum peak ground acceleration (PGA) of the earthquake event and ao is the unique value PGA that characterizes each municipality shown on the Greek hazard map. The relative and cumulative frequencies of the different damage states for each structural type and each intensity level are computed in terms of damage ratio. Damage probability matrices (DPMs) and vulnerability curves are obtained for specific structural types. A comparison analysis is fulfilled between the produced and the existing vulnerability models.  相似文献   

10.
In this paper earthquake damage scenarios for residential buildings (about 4200 units) in Potenza (Southern Italy) have been estimated adopting a novel probabilistic approach that involves complex source models, site effects, building vulnerability assessment and damage estimation through Damage Probability Matrices. Several causative faults of single seismic events, with magnitude up to 7, are known to be close to the town. A seismic hazard approach based on finite faults ground motion simulation techniques has been used to identify the sources producing the maximum expected ground motion at Potenza and to generate a set of ground motion time histories to be adopted for building damage scenarios. Additionally, site effects, evaluated in a previous work through amplification factors of Housner intensity, have been combined with the bedrock values provided by hazard assessment. Furthermore, a new relationship between Housner and EMS-98 macroseismic intensity has been developed. This relationship has been used to convert the probability mass functions of Housner intensity obtained from synthetic seismograms amplified by the site effects coefficients into probability mass function of EMS-98 intensity. Finally, the Damage Probability Matrices have been applied to estimate the damage levels of the residential buildings located in the urban area of Potenza. The proposed methodology returns the full probabilistic distribution of expected damage, thus avoiding average damage index or uncertainties expressed in term of dispersion indexes.  相似文献   

11.
The paper analyses the seismic fragility of precast reinforced concrete buildings using observational damage data gathered after the 2012 Emilia earthquakes that struck Northern Italy. The damage level in 1890 buildings was collected, classified and examined. Damage matrices were then evaluated, and finally, empirical fragility curves were fitted using Bayesian regression. Building damage was classified using a six‐level scale derived from EMS‐98. The completeness of the database and the spatial distribution of the buildings investigated were analysed using cadastral data as a reference. The intensity of the ground motion was quantified by the maximum horizontal peak ground acceleration, which was obtained from ShakeMaps. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

12.
对欧洲98地震烈度表(EMS—98)作了筒要介绍,内容包括不同建筑结构类型的易损性等级、钢混建筑的破坏等级、砖石建筑的破坏等级、描述性术语的定量意义、欧洲98地震烈度表中考察的影响因素及烈度表全文。  相似文献   

13.
汶川地震中离震中较远地区的高层建筑的震害   总被引:2,自引:1,他引:1  
汶川地震中,陕西省西安市和宝鸡市两地处于远震区。远震区高层建筑比多层建筑的震害重。这两地高层建筑的震害主要表现为砌体填充墙和隔墙普遍出现裂缝;房屋顶部附近防震缝两侧的装饰材料震损,部分混凝土构件被撞坏;楼梯间的填充墙普遍开裂等。主体结构中的混凝土梁、柱和剪力墙等承重构件一般没有可见裂缝,部分剪力墙洞口连梁及框架一剪力墙结构中的连梁出现剪切斜裂缝或弯曲裂缝。文中初步分析了震害原因,并提出了设计建议。  相似文献   

14.
In this paper, the investigations on seismotectonic and intensity evaluations of epicentral and meizoseismal regions in Muzaffarabad earthquake—8 Oct. 2005, Mw 7.6—are summarized using The European Macroseismic Scale (EMS-98). The observations are compiled based on the field investigations and isoseismal map. The results show that the isoseismals are elongated parallel to the reactivated Muzaffarabad fault, and the attenuation is high in the direction normal to the fault compared with the direction parallel to it. The geotechnical investigations in Muzaffarabad Valley have helped the authors to assign intensity values in the localities where some huge landslides are observed. Finally, the empirical laws, previously developed for intensity attenuation in Iran in EMS-98 scale, are compared with the intensity observations here. The results are roughly consistent with the general form of attenuation laws. However, it is found that the intensity attenuations are different in the directions normal and parallel to the fault.  相似文献   

15.
16.
On 6th April 2009 an earthquake of magnitude M w =  6.3 occurred in the Abruzzo region; the epicentre was very close to the city of L’Aquila (about 6 km away). The event produced casualties and damage to buildings, lifelines and other infrastructures. An analysis of the main damage that reinforced concrete (RC) structures showed after the event is presented in this study. In order to isolate the main causes of structural and non-structural damage, the seismological characteristics of the event are examined, followed by an analysis of the existing RC building stock in the area. The latter issue came under scrutiny after the release of official data about structural types and times of construction, combined with a detailed review of the most important seismic codes in force in the last 100 years in Italy. Comparison of the current design provisions of the Italian and European codes with previous standards allows the main weaknesses of the existing building stock to be determined. Damage to structural and non-structural elements is finally analyzed thanks to photographic material collected in the first week after the event; the main causes of damage are then inferred.  相似文献   

17.
为了研究2021年5月22日玛多MS 7.4地震地震动特征,收集16个强震台的峰值加速度和其中9个台的强震波形数据,利用峰值加速度衰减及反应谱等分析玛多MS 7.4地震强震动特征。结果表明,多数台站的PGA值都随震中距的增大而平稳下降,PGA的衰减特征与青藏区衰减关系间有较好的一致性;土层台与基岩台的加速度反应谱明显不同,震中距越小,短周期高频成分越多,衰减越快,震中距越大,长周期高频成分越少,衰减越慢;加速度反应谱的水平向与竖向比值曲线在4 s内呈现两峰一谷的现象,初步认为,距发震断层较近的野马滩1号大桥所受到的破坏及水泥路面的明显错断受水平向地震动作用的影响更大。  相似文献   

18.
The 2003 Ml = 5.4 Rambervillers earthquake, north-east of France, is the largest seismic event recorded north of the Alps since the 1992 Ms = 5.3, I0 = VII, Roermond earthquake, Netherlands. With a maximum macroseismic intensity of VI-VII EMS-98, the 2003 event was broadly felt to a distance of 300 km from the epicentre. It provides a unique opportunity to test and compare the different procedures used in France, Germany and Switzerland when evaluating macroseismic intensities. The main purpose of this paper is to present a common transfrontier macroseismic map based on the EMS-98 intensity scale. Maximum horizontal accelerations recorded in the area are compared to the intensity values, and we propose to use a differential technique to re-estimate the magnitude of the 1682 Remiremont, I0 = VIII, earthquake, which occurred 40 km south of Rambervillers.  相似文献   

19.
Excavations in the former Roman provincial capital of Pannonia Superior, Carnuntum, 40 km east of Vienna revealed damaged masonry structures from many parts of the ancient settlements. A compilation of structurally damaged buildings has formerly been given by Kandler (Acta Archaeol Acad Sci Hung, 41:313–336, 1989), who related damage to an earthquake in the middle of the fourth century a.d. This paper reviews and supplements these data, and discusses the significance of the style of damage. It is concluded that seismic damage is the only likely interpretation for the damaging mechanism. Although archaeological age dating for the individual collapsed buildings only constrains the timing of their destruction to a few decades around 350 a.d., we assume a single damaging event. In spite of the restrictions on damage assessment by the nature of the archaeological data, it is possible to give a reasonable appraisal of macroseismic intensity. The tentative seismological interpretation of damage leads to an intensity estimate of about nine of the European macroseismic scale (EMS-1998). Comparison with macroseismic data of modern earthquakes in the region, which show a rapid decrease of intensity with distance form the epicentre, indicate a near-by seismic source unless exceptionally high epicentral intensities are assumed for the fourth century event. The most likely source is an active sinistral strike-slip fault (Lassee Fault) passing about 8 km NW of the archaeological site. The fault belongs to Vienna Basin fault system with about 2 mm sinistral movement per year. The system is characterized by fault segmentation and distinct seismicity along the different segments. Moderate seismicity during the last centuries at the southern segments (e.g., Schwadorf 1927, I 0=8) strongly contrasts from the Lassee fault segment with Carnuntum as the only known severe earthquake. The earthquake of Carnuntum provides evidence for the overall seismic style of deformation along this segment, which previously has not been regarded seismically active. Also, the fourth century earthquake is the strongest event known from the Vienna Basin fault so far.  相似文献   

20.
For the first time after the finalisation of the European Norm for seismic design of buildings (Eurocode 8 – EC8),the performance of RC buildings designed with this code is evaluated through systematic nonlinear analyses. Regular 4-, 8- or 12-storey RC frames are designed for a PGA of 0.2 or 0.4 g and to one of the three alternative ductility classes in EC8. As the Eurocodes are meant to replace soon existing national codes, design and performance is also compared to that of similar frames designed with the 2000 Greek national codes. The performance of alternative designs under the life-safety (475 years) and the damage limitation (95 years) earthquakes is evaluated through nonlinear seismic response analyses. The large difference in material quantities and detailing of the alternative designs does not translate into large differences in performance. Design for either Ductility Class High (H) or Medium (M) of EC8 is much more cost-effective than design for Ductility Class Low (L), even in moderate seismicity. It is also much more cost-effective than design to the 2000 Greek national codes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号