首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new isolation interface is proposed in this study to retrofit existing buildings with inadequate soft stories as well as new structures to be constructed with soft first story intended for architectural or functional purposes. The seismic interface is an assembly of bearings set in parallel on the top of the first story columns: the multiple‐slider bearings and rubber bearings. The multiple‐slider bearing is a simple sliding device consisting of one horizontal and two inclined plane sliding surfaces based on polytetrafluoroethylene and highly polished stainless steel interface at both ends set in series. A numerical example of a five‐story reinforced concrete shear frame with soft first story is considered and analyzed to demonstrate the efficiency of the proposed isolation system in reducing the ductility demand and damage in the structure while maintaining the superstructure above the bearings to behave nearly in the elastic range with controlled bearing displacement. Comparative study with the conventional system as well as various isolation systems such as rubber bearing interface and resilient sliding isolation is carried out. Moreover, an optimum design procedure for the multiple‐slider bearing is proposed through the trade‐off between the maximum bearing displacement and the first story ductility demand ratio. The results of extensive numerical analysis verify the effectiveness of the multiple‐slider bearing in minimizing the damage from earthquake and protecting the soft first story from excessively large ductility demand. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
Non‐ductile reinforced concrete buildings represent a prevalent construction type found in many parts of the world. Due to the seismic vulnerability of such buildings, in areas of high seismic activity non‐ductile reinforced concrete buildings pose a significant threat to the safety of the occupants and damage to such structures can result in large financial losses. This paper introduces advanced analytical models that can be used to simulate the nonlinear dynamic response of these structural systems, including collapse. The state‐of‐the‐art loss simulation procedure developed for new buildings is extended to estimate the expected losses of existing non‐ductile concrete buildings considering their vulnerability to collapse. Three criteria for collapse, namely first component failure, side‐sway collapse, and gravity‐load collapse, are considered in determining the probability of collapse and the assessment of financial losses. A detailed example is presented using a seven‐story non‐ductile reinforced concrete frame building located in the Los Angeles, California. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
以汶川地震为研究背景,针对震后典型钢筋混凝土框架结构进行地震易损性研究。基于Cornell理论框架结合汶川地质资料,拟合出考虑场地特点的地震危险性模型,同时定义损伤水平状态及限值指标,以概率解析易损性研究方法为基础,运用考虑地震动参数的解析易损性评估方法绘制汶川地区钢筋混凝土框架建筑的地震易损性曲线。研究结果表明:考虑地震动参数的概率解析易损性研究方法是一种有效的地震易损性评估方法;以PGA作为地震强度输入指标的结构反应,随自振周期的增大体系最大响应的相关性降低,结构各个损伤状态的失效概率均随之增大。  相似文献   

4.
三层地铁车站振动台试验分析   总被引:3,自引:0,他引:3  
为了探究多层地下结构地震破坏机理,进行了三层地铁车站振动台试验.试验采用微粒混凝土模型,严格按照相似比和配筋率对模型进行加筋配置.填土采用哈尔滨地铁施工挖掘出的扰动土.装土箱采用自主研制的层叠剪切箱以减小边界效应.通过对试验加速度和应变的分析可得到以下主要结论:(1)地下结构在地震中的破坏,主要是由位移控制的;(2)多...  相似文献   

5.
Recent earthquakes have confirmed the role played by infills in the seismic response of reinforced concrete buildings. The control and limitation of damage to such nonstructural elements is a key issue in performance‐based earthquake engineering. The present work is focused on modeling and analysis of damage to infill panels, and, in particular, it is aimed towards linear analysis procedures for assessing the damage limitation limit state of infilled reinforced concrete frames. First, code provisions on infill modeling and acceptance criteria at the damage limitation limit state are reviewed. Literature contributions on damage to unreinforced masonry infill panels and corresponding displacement capacity are reported and discussed. Two procedures are then proposed aiming at a twofold goal: (i) the determination of ‘equivalent’ interstory drift ratio limits for a bare frame model and (ii) the estimation of the stiffness of equivalent struts representing infill walls in a linear model. These two quantities are determined such that a linear model ensures a reliable estimation of seismic capacity at the damage limitation limit state, providing the same intensity level as that obtained from nonlinear analyses carried out on structural models with infills. Finally, the proposed procedures are applied to four‐story and eight‐story case study‐infilled frames, designed for seismic loads according to current technical codes. The results of these application examples are presented and discussed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
This paper discusses the importance of including the bond‐slip effects in assessing the response under cyclic loads of reinforced concrete frames. The discussion is based on analyses performed using numerical models which are simple, computationally efficient and capable of representing the salient features of reinforced concrete frames under both static and dynamic loads. The numerical models comprise a displacement‐based, reinforced concrete frame element with bond‐slip and a rigid beam column joint element with bond‐slip. Two applications illustrate the model accuracy and show the importance of including bond‐slip. The first application considers a reinforced concrete beam‐column subassemblage experimentally tested under cyclic loads. The second application considers the shaking table test of a two‐story one‐bay reinforced concrete frame In both cases the analytical results correlate well with the experimental results in terms of strength, displacement demands and hysteretic energy dissipation. Furthermore, the paper shows how the analyses that include bond‐slip yield a better correlation with the experimental results with respect to the analyses that assume a perfect bond. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

7.
目前的既有钢混结构地震损伤研究没有同时考虑不同抗震设计规范差异和耐久性两个因素对结构抗震性能的影响,且损伤指标较简单,在动力损伤分析中也存在局限。基于云模型的特点,提出了包括弹塑性耗能差率、刚度损伤指数、层间位移角和顶点位移角的多元结构损伤状态综合评估方法,能够同时考虑结构各损伤指数的随机性和模糊性。考虑不同版本抗震设计规范造成的结构性能差异和耐久性下降对结构性能的影响,设计3个典型五层钢混框架结构,进行增量动力分析,验证损伤评估方法的准确性。结果表明:随着抗震规范版本的更新,结构的损伤程度有适当减轻;同一结构的损伤程度因混凝土碳化作用先减轻后加重;采用弹塑性耗能差率表征既有结构的地震损伤效果优于刚度损伤指数;基于多指标云模型损伤评估方法获得的云模型综合隶属度和综合损伤值能够更加细化和精确地描述结构损伤状态。  相似文献   

8.
广州天誉大厦采用型钢混凝土框架一钢筋混凝土筒体的混合结构体系,地面以上结构采用抗震缝兼伸缩缝分隔为南、北塔两个独立结构体系,南塔高186.5 m,北塔高159.5 m.两塔的核心筒总宽度与核心筒总高的比值均超出了规范限值.为研究这种超限高层混合结构的抗震性能,对其进行了缩尺(1/30)模型的振动台试验,并建立了有限元计...  相似文献   

9.
An analytical seismic fragility assessment framework is presented for the existing low strength reinforced concrete structures more common in the building stock of the developing countries.For realistic modelling of such substandard structures,low strength concrete stress-strain and bond-slip capacity models are included in calibrating material models.Key capacity parameters are generated stochastically to produce building population and cyclic pushover analysis is carried out to capture inelastic behaviour.Secant period values are evaluated corresponding to each displacement step on the capacity curves and used as seismic demand.A modified capacity demand diagram method is adopted for the degrading structures,which is further used to evaluate peak ground acceleration from back analysis considering each point on the capacity curve as performance point.For developing fragility curves,the mean values of peak ground acceleration are evaluated corresponding to each performance point on the series of capacity curves.A suitable probability distribution function is adopted for the secant period scatter at different mean peak ground acceleration values and probability of exceedance of limit states is evaluated.A suitable regression function is used for developing fragility curves and regression coefficients are proposed for different confidence levels.Fragility curves are presented for a low rise pre-seismic code reinforced concrete structure typical of developing countries.  相似文献   

10.
Nonstructural reinforced concrete flat walls architecturally designed as exterior/partition walls in concrete buildings were severely damaged by the 2011 earthquake off the Pacific coast of Tohoku. This damage was observed in the monolithic nonstructural flat walls of relatively old ductile concrete buildings. Although these flat walls might affect the overall seismic performance and behavior of a building, the nonstructural wall effects have not been clarified because of the complex interactions among the structural components. To understand these effects, this paper conducts an experimental and numerical investigation of the nonstructural wall effects, focusing on a typical residential building damaged by the 2011 earthquake. A single‐story, one‐bay moment‐resisting frame model of the building with a nonstructural flat wall was tested to clarify the fundamental behavior. The results reveal that the wall significantly contributed to the seismic performance of the overall frame until it failed in shear, subsequently losing structural effectiveness. Such experimental wall behavior could be simulated by the isoparametric element model. Moreover, the structural effects of the nonstructural flat walls on the global seismic performance and behavior of the investigated building were discussed through earthquake response analyses using ground motions recorded near the building site and pushover analyses. Consequently, the building damage could be simulated in an analytical case considering the nonstructural flat walls, showing larger inter‐story drifts in the lower stories due to softening of the walls. The analytical results also indicated that the softening of the nonstructural flat walls decreased the building ductility, as defined by ultimate inter‐story drifts. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

11.
评估钢筋混凝土结构抗损性具有重要工程意义,但目前以单因素叠加为基础的评估方法误差较大。为解决此问题,提出基于多元模糊的钢筋混凝土结构地震抗损性评估方法。以Park-Ang地震损伤模型为前提,引入正规化累积耗能参数,得到建筑结构层间损伤表达式,加权平均获取震后建筑结构整体损伤值;利用有害层间位移角参数计算震后结构层间位移角;将获取的结构整体损伤值、层间位移角作为多因素论域,进行多元模糊结构抗损性评估,选取模糊损伤评估数学模型与隶属度函数,克服单一因素影响,计算判别因素权重与结构综合损伤指数,根据结构抗损性能判断规则得到建筑结构抗损性所属标准。经实验测试验证:基于多元模糊的钢筋混凝土结构地震抗损性评估方法精确度大于95%,评估精确性高,是一种有效的钢筋混凝土结构抗损性评估方法。  相似文献   

12.
地震作用后钢筋混凝土框架结构恢复性模拟研究   总被引:1,自引:1,他引:0       下载免费PDF全文
陈竣  罗凡 《地震工程学报》2019,41(3):568-573
钢筋混凝土框架结构在地震冲击后,其刚体退化特性复杂,存在模拟时结果失真明显的问题。为此,在考虑刚度退化规律的基础上进行分析模拟,研究地震冲击下钢筋混凝土框架结构的恢复性。提取地震作用下钢筋混凝土框架结构滞回曲线,通过有限元分析获取不同的特征点,形成恢复力模型的骨架曲线;依据恢复力模型骨架曲线和刚度退化规律,构建滞回曲线,模拟地震作用后钢筋混凝土框架结构恢复过程。在模拟的钢筋混凝土框架结构恢复实验中,层间位移结果低于5 mm、层间绝对加速度和柱底抬升结果的误差均低于0.1 mm;模拟得到结构的弯矩缝隙都能够实现闭合,钢筋混凝土结构未出现屈服现象,说明模拟的结果较好。  相似文献   

13.
本文用钢管混凝土柱作为结构底层耗能柱、用承重墙和隔震器控制结构底层倒塌破坏,从而提出了一种新的耗能-隔震柔性底层结构体系。通过本文12根钢管混凝土柱和文献[7]中7根钢管混凝土柱的低周疲劳实验,初步确定了钢管混凝土柱地震损伤模型的参数;通过两个钢管混凝土-钢筋混凝土三层框架模型和一个纯钢筋混凝土三层框架模型的拟动力实验,研究和比较了两类结构体系的地震损伤。  相似文献   

14.
In this paper, correlation between the ground motion parameters and the peak displacement demand of a reinforced concrete single degree of freedom system retrofitted by friction dampers is investigated. The aim is to reveal the best parameters that are used in selecting earthquake records for nonlinear dynamic analysis of the system. Performing numerous nonlinear time history analyses, it is observed that different earthquake parameters play role in peak displacement demand related to the ranges formed by the different periods of a reinforced concrete frame, the strength ratio of total system at slip displacement and the stiff/soft soil profiles. For the both soil types, out of sixteen ground motion parameters, the eight, Spectral Response Acceleration, Peak Ground Acceleration, Effective Peak Acceleration, Maximum Incremental Velocity, Peak Ground Velocity, Arias Intensity, Arias Intensity-based Parameter and Effective Peak Velocity correlate better with peak displacement demand.  相似文献   

15.
A mathematical model for reinforced concrete frame members is presented, which is different from others presented in the literature in that the finite size of the plastic regions is taken into account. Moreover, the model requires the specification of only elementary material properties of steel and concrete to simulate the complete behaviour under strong cyclic loads. To facilitate the analysis of damaged concrete frames, element and global damage parameters are introduced which permit the estimation of all initial conditions from only a few basic variables which can be obtained from post-earthquake field inspections, such as the residual roof displacement. The accuracy of the model is demonstrated in a series of three examples wherein analytical response predictions are compared with available experimental test data.  相似文献   

16.
Self‐centering reinforced concrete frames are developed as an alternative of traditional seismic force‐resisting systems with better seismic performance and re‐centering capability. This paper presents an experimental and computational study on the seismic performance of self‐centering reinforced concrete frames. A 1/2‐scale model of a two‐story self‐centering reinforced concrete frame model was designed and tested on the shaking table in State Key Laboratory of Disaster Reduction in Civil Engineering at Tongji University to evaluate the seismic behavior of the structure. A structural analysis model, including detailed modeling of beam–column joints, column–base joints, and prestressed tendons, was constructed in the nonlinear dynamic modeling software OpenSEES. Agreements between test results and numerical solutions indicate that the designed reinforced concrete frame has satisfactory seismic performance and self‐centering capacity subjected to earthquakes; the self‐centering structures can undergo large rocking with minor residual displacement after the earthquake excitations; the proposed analysis procedure can be applied in simulating the seismic performance of self‐centering reinforced concrete frames. To achieve a more comprehensive evaluation on the performance of self‐centering structures, research on energy dissipation devices in the system is expected. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
刘科 《震灾防御技术》2022,17(3):579-588
为量化地震作用下钢筋混凝土(RC)柱损伤情况和变形,并将不同地震破坏状态下RC柱损伤和变形进行分析。从太平洋地震工程研究中心(PEER)数据库中收集91组RC柱抗震试验数据,选取4种广泛应用的构件损伤模型进行计算,将损伤发展曲线与层间位移角发展曲线进行对比分析。对RC柱损伤指标限值进行归一化处理,统计分析后得到不同破坏等级下的位移角限值,并给出了RC柱各破坏等级下的位移角限值与损伤指标限值对应关系。研究结果表明,牛荻涛损伤模型可更准确地评价地震作用下结构构件损伤程度,且与层间位移角发展曲线均呈近似线性增长趋势;不同破坏等级下的位移角限值验算保证率均>80%,表明本文提出的位移角限值具有一定合理性。  相似文献   

18.
A damage‐function model is proposed for the inelastic response of structures in terms of initial damage and of displacement amplitudes and secant stiffnesses of response cycles. The model is used to obtain an analytical closed‐form solution for the probability distribution of cumulative damage after an earthquake ground motion given the distribution prior to such excitation and information on the inelastic structural response. The formulation is applied to a reinforced concrete frame and the results show the capabilities of the method to yield updated distributions of damage. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

19.
This paper describes an analytical investigation on a reinforced concrete lateral load resisting structural system comprising a pin‐supported (base‐rocking) shear wall coupled with a moment frame on 1 or both sides of the wall. Yielding dampers are used to provide supplemental energy dissipation through the relative displacements at the vertical connections between the wall and the frames. The study extends a previous linear‐elastic model for pin‐supported wall‐frame structures by including the effects of the dampers. A closed‐form solution of the lateral load behavior of the structure is derived by approximating the discrete wall‐frame‐damper interactions with distributed (ie, continuous) properties. The validity of the model is verified by comparing the closed‐form results with computational models using OpenSees program. Then, a parametric analysis is conducted to investigate the effects of the wall, frame, and damper stiffness on the behavior of the structure. It is found that the damper stiffness significantly affects the distribution of shear forces and bending moments over the wall height. Finally, the performance‐based plastic design approach extended to the wall‐frame‐damper system is proposed. Case studies are carried out to design 2 damped pin‐supported wall‐frame structures using the proposed approach. Nonlinear dynamic time‐history analyses are conducted to verify the effectiveness of this method. Results indicate that the designed structures can achieve the performance level with the story drift ratios less than target values, and weak‐story failure mechanism is not observed. The approach can be used in engineering applications.  相似文献   

20.
By advancing the technologies regarding seismic control of structures and development of earthquake resistance systems in the past decades application of different types of earthquake energy dissipation system has incredibly increased. Viscous damper device as a famous and the simplest earthquake energy dissipation system is implemented in many new structures and numerous number of researches have been done on the performance of viscous dampers in structures subjected to earthquake. The experience of recent severe earthquakes indicates that sometimes the earthquake energy dissipation devices are damaged during earthquakes and there is no function for structural control system. So, damage of earthquake energy dissipation systems such as viscous damper device must be considered during design of earthquake resistance structures.This paper demonstrates the development of three-dimensional elasto-plastic viscous damper element consisting of elastic damper in the middle part and two plastic hinges at both ends of the element which are compatible with the constitutive model to reinforce concrete structures and are capable to detect failure and damage in viscous damper device connections during earthquake excitation. The finite element model consists of reinforced concrete frame element and viscous damper element is developed and special finite element algorithm using Newmark׳s direct step-by-step integration is developed for inelastic dynamic analysis of structure with supplementary elasto-plastic viscous damper element. So based on all the developed components an especial finite computer program has been codified for “Nonlinear Analysis of Reinforced Concrete Buildings with Earthquake Energy Dissipation System”. The evaluation of seismic response of structure and damage detection in structural members and damper device was carried out by 3D modeling, of 3 story reinforced concrete frame building under earthquake multi-support excitation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号