首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
The hydraulic conductivity represents an important indicator parameter in the generation and redistribution of excess pore pressure of sand–silt mixture soil deposits during earthquakes. This paper aims to determine the relationship between the undrained shear strength (liquefaction resistance) and the saturated hydraulic conductivity of the sand–silt mixtures and how much they are affected by the percentage of low plastic fines (finer than 0.074 mm) and void ratio of the soil. The results of flexible wall permeameter and undrained monotonic triaxial tests carried out on samples reconstituted from Chlef river sand with 0, 10, 20, 30, 40, and 50 % non-plastic silt at an effective confining pressure of 100 kPa and two initial relative densities (D r = 20, 91 %) are presented and discussed. It was found that the undrained shear strength (liquefaction resistance) can be correlated to the fines content, intergranular void ratio and saturated hydraulic conductivity. The results obtained from this study reveal that the saturated hydraulic conductivity (k sat) of the sand mixed with 50 % low plastic fines can be, in average, four orders of magnitude smaller than that of the clean sand. The results show also that the global void ratio could not be used as a pertinent parameter to explain the undrained shear strength and saturated hydraulic conductivity response of the sand–silt mixtures.  相似文献   

2.
Compacted soil–bentonite liners, consisting of a sandy soil mixed with bentonite as backfill, are used extensively as engineered barriers for contaminant containment. This paper studies the valorization of local materials containing calcareous sand, tuff obtained from Laghouat region (in the South Algeria), to associate with bentonite in order to improve their hydraulic characteristics for use as landfill liner material. Firstly, a geotechnical characterization of mixtures chooses from a fixed percentage to 10% bentonite and different percentages of calcareous sand and tuff so that they are complementary to 90% by not 10%. Thereafter, the determination of saturated hydraulic conductivity at falling-head permeability (Kv) and oedometer (Kid, indirect Measure) tests of all compacted mixtures at Optimum Normal Proctor have been carried out using both permeates by tap water and a landfill leachate in order to simulate long-term conditions. The results showed that the saturated hydraulic conductivity of tap water is relatively lower than the one saturated by leachate in the falling-head test, unlike the oedometer test. The B10CS20T70 mixture has satisfied the hydraulic conductivity criterion of bottom barriers (i.e. water permeated: kv20° = 1.97 × 10?9 and kid from 7 × 10?9 to 1.83 × 10?10 < 10?9m/s; leachate permeated: kv20° = 2.91 × 10?9 and kid from 7 × 10?9 at 1.44 × 10?10 < 10?9 m/s). Finally, a comparison between direct measurements of the saturated hydraulic conductivity by triaxial (Kd) test and oedometer test (Kid) in the range of effective stress applied 100–800 kPa led to propose equations of correlations between these two methods. In conclusion, adopted formulation B10CS20T70 perfectly meets the regulatory requirements in force and constitutes an economic product based on available local materials for engineers barriers.  相似文献   

3.
The characteristics of hydrocarbon-contaminated soils have been among major concerns of geotechnical engineers due to its significant frequency of event and also its influential consequences on our surroundings from various environmental and engineering viewpoints. Heretofore, the effects of diverse kinds of hydrocarbon contaminants on majority of geotechnical properties of fine- and coarse-grained soils such as grain size, hydraulic conductivity, plasticity, compressibility, internal friction, cohesion, and shear strength have been investigated. However, there has not been a concentrated research study examining shear wave velocity (\({\text{V}}_{\text{s}}\)) of hydrocarbon-contaminated soils as an important geotechnical property of soil due to this fact that, in small/very small strain levels, the maximum shear modulus of soils (\({\text{G}}_{ \hbox{max} }\)) can be determined using shear wave velocity (\({\text{G}}_{ \hbox{max} } =\uprho{\text{V}}_{\text{s}}^{2}\)). This paper aims to investigate effects of hydrocarbon contamination on shear wave velocity of sandy soils by comparing shear wave velocities in identically prepared clean and contaminated samples. To this aim, an Iranian light crude oil, a standard type of silica sand (Ottawa sand), and a bender element apparatus were used to minutely measure shear wave velocity of clean and crude oil contaminated sand samples. Moreover, dry and quasi-moist tamping methods were employed in order to provide comparable clean and contaminated specimens (containing 4, 6, 8, 10, and 12 wt% of crude oil), respectively. Firstly, a comprehensive bender element (BE) and resonant column tests were conducted on the identically prepared clean sand samples at various amounts of frequency (2–20 kHz) and under various confining pressure (50–500 kPa) to find the best methods of accurately determining shear wave travel time in BE tests. Thereafter, BE tests were conducted to examine shear wave velocity in contaminated specimens. Based on the results, it was found that there was a critical value for crude oil content with the maximum shear wave velocity so that shear wave velocity of 4 wt% contaminated sand (Vs-4 wt%) was about 1.2 times higher than clean one (Vs-clean), and contrastingly adding further crude oil up to 6 wt% made a significant reduction in value of shear wave velocity to some extent that Vs-6 wt% was slightly lower than Vs-clean (Vs-6 wt% = 0.95–0.97Vs-clean). Moreover, adding more contaminant (8–12 wt%) into sand had negligible influences on shear wave velocity. In this paper, the effects of crude oil contamination on sand microstructure were also evaluated using scanning electron microscopy.  相似文献   

4.
Soil-bentonite (SB) backfill is used extensively in cutoff walls at landfill sites; the walls are used as engineered geotechnical barriers for contaminant control. With increasing bentonite content, the coefficient of consolidation and hydraulic conductivity of the SB decrease. However, when the bentonite content is increased beyond a certain percentage, the hydraulic conductivity of the SB decreases very little. One of the aims of this paper is to introduce the concept of optimal bentonite content (OBC) for SB cutoff walls, in which the hydraulic conductivity (kh) is expected to be lower than 1?×?10?9 m/s. Additionally, the paper introduces a new index consolidation stress ratio, cvσ′, which is used to obtain the OBC. For this study, the initial water contents of the SB backfill material are selected to be 0.8, 1.0, and 1.2 times their corresponding liquid limits. The clayey soils are amended with different bentonite contents, 0, 5, 8, and 10% (by dry weight basis) for the oedometer tests. Then, piezocone penetration test (CPTU) is applied in SB cutoff wall at a landfill site in Jingjiang city, China. The results of the laboratory and field studies show that the introduction of a new index, cvσ′, is very useful for calculating the OBC and for evaluating the coefficient of consolidation and hydraulic conductivity of SB backfill. The advantage of SB backfill with OBC is that it can achieve the design requirement of very low hydraulic conductivity and improve the safety reserves.  相似文献   

5.
A transparent aqueous-saturated sand surrogate for use in physical modeling   总被引:3,自引:0,他引:3  
This paper presents the geotechnical properties of a new family of synthetic transparent soils made of fused quartz, saturated with a matched refractive index water-based sucrose solution, suitable for modeling the behavior of sand in small-scale model tests. The dry density ranged between 1,134 and 1,358 kg/m3. The peak angle of friction was found to range from 46° to 57°. The average hydraulic conductivity was 1.7 × 10?5 cm/s. The compressibility index (C c) ranged from 0.34 to 0.57. The main advantage of fused quartz over available sand surrogates made of silica gel is that its solid structure better models the behavior of natural sand. The matching pore fluids are inert and non-toxic, which facilitates their use in educational settings. The availability of a safe and easy-to-use transparent sand permits measurement of three-dimensional deformation patterns and flow characteristics in controlled research experiments. The introduction of an aqueous solution permits the use of two immiscible pore fluids, one made of mineral oil and the other made of a sucrose solution, for modeling multiphase flow problems, as well as coupled flow-deformation problems.  相似文献   

6.
The groundwater abstracted at a well field near the Yamuna River in Central Delhi, India, has elevated ammonium (NH4 +) concentrations up to 35 mg/L and arsenic (As) concentrations up to 0.146 mg/L, constituting a problem with the provision of safe drinking and irrigation water. Infiltrating sewage-contaminated river water is the primary source of the NH4 + contamination in the aquifer, leading to reducing conditions which probably trigger the release of geogenic As. These conclusions are based on the evaluation of six 8–27-m deep drillings, and 13 surface-water and 69 groundwater samples collected during seven field campaigns (2012–2013). Results indicate that losing stream conditions prevail and the river water infiltrates into the shallow floodplain aquifer (up to 16 m thickness), which consists of a 1–2-m thick layer of calcareous nodules (locally known as kankar) overlain by medium sand. Because of its higher hydraulic conductivity (3.7 × 10?3 m/s, as opposed to 3.5 × 10?4 m/s in the sand), the kankar layer serves as the main pathway for the infiltrating water. However, the NH4 + plume front advances more rapidly in the sand layer because of its significantly lower cation exchange capacity. Elevated As concentrations were only observed within the NH4 + plume indicating a causal connection with the infiltrating reducing river water.  相似文献   

7.
The main objective of this paper was to investigate the dewatering behaviour of a clayey uranium ore slurry. The slurry (containing 28% clay size) exhibited moderate water adsorption (w l  = 83% and w p  = 30%). Primarily composed of muscovite (46%) and quartz (30%), the clay minerals included illite (8%), chlorite (5%) and kaolinite (2%) alongside a CEC of 41 (cmol(+)/kg) with Ca2+ and Mg2+ as the dominant cations. Likewise, the high EC (17,600 μS/cm) and ionic strength (1.15 mol/L) indicated a flocculated microstructure due to the presence of SO4 2? (22,600 mg/L) and Mg2+ (1340 mg/L) in the slurry water. Settling included sedimentation and consolidation at low initial solids condition (25–35%) whereas only consolidation was observed at high initial solids contents (40–50%). The average k reduced from 1.2 × 10?6 m/s (initial s = 25%) to 5.3 × 10?8 m/s (initial s = 50%) along with a void ratio reduction from 7.4 to 2.6. Due to thixotropic strength, volume compressibility during consolidation showed apparent pre-consolidation at low effective stress (0.3–2 kPa) with a reduction in void ratio from 2.6 to 2.5. The e s was found to be 2.46 at σ′ = 2 kPa and was followed by a steeper slope with the void ratio reducing to 2.1 at σ′ = 31 kPa. Likewise, the hydraulic conductivity during consolidation decreased from 2.6 × 10?9 m/s (at e = 2.6) to 2.0 × 10?10 m/s (at e = 2.1).  相似文献   

8.
Biosurfactants are frequently used in petroleum hydrocarbon and dense non-aqueous phase liquids (DNAPLs) remediation. The applicability of biosurfactant use in clayey soils requires an understanding and characterization of their interaction. Comprehensive effects of surfactants and electrolyte solutions on kaolinite clay soil were investigated for index properties, compaction, strength characteristics, hydraulic conductivities, and adsorption characteristics. Sodium dodecyl sulfate (SDS) and NaPO3 decreased the liquid limit and plasticity index of the test soil. Maximum dry unit weights were increased and optimum moisture contents were decreased as SDS and biosurfactant were added for the compaction tests for mixtures of 30% kaolinite and 70% sand. The addition of non-ionic surfactant, biosurfactant, and CaCl2 increased the initial elastic modulus and undrained shear strength of the kaolinite–sand mixture soils. Hydraulic conductivities were measured by fixed-wall double-ring permeameters. Results showed that the hydraulic conductivity was not significantly affected, but slightly decreased from 1×10−7 cm/s (water) to 0.3×10−7 cm/s for Triton X-100 and SDS. The adsorption characteristics of the chemicals onto kaolinite were also investigated by developing isotherm curves. SDS adsorbed onto soil particles with the strongest bonding strength of the fluids tested. Correlations among parameters were developed for surfactants, electrolyte solutions, and clayey soils.  相似文献   

9.
Abstract Reliable predictions of wind erosion depend on the accuracy of determining whether erosion occurs or not. Among the several factors that govern the initiation of soil movement by wind, surface moisture is one of the most significant. Some widely used models that predict the threshold shear velocity for particle detachment of wet soils by wind were critically reviewed and evaluated. Wind‐tunnel experiments were conducted on pre‐wetted dune sand with moisture contents ranging from 0·00 to 0·04 kg kg?1. Sand samples were exposed to different wind speeds for 2 min. Moisture content was determined gravimetrically before and after each experiment, and the saltation of sand particles was recorded electronically with a saltiphone. Shear velocities were deduced from the wind speed profiles. For each moisture content, the experiments were repeated at different shear velocities, with the threshold shear velocity being determined by least‐squares analysis of the relationships between particle number rates and shear velocity. Within the 2‐min test runs, temporal changes in particle number rates and moisture contents were detected. A steep increase in the threshold shear velocity with moisture content was observed. When comparing the models, large differences between the predicted results became apparent. At a moisture content of 0·007 kg kg?1, which is half the moisture content retained to the soil matrix at a water tension (or matric potential) of ?1·5 MPa, the increase in ‘wet’ threshold shear velocity predicted with the different models relative to the dry threshold shear velocity ranged from 117% to 171%. The highest care should therefore be taken when using current models to predict the threshold shear velocity of wet sediment. Nevertheless, the models of Chepil (1956; Proc. Soil Sci. Soc. Am., 20, 288–292) and Saleh & Fryrear (1995; Soil Sci., 160, 304–309) are the best alternatives available.  相似文献   

10.
The influence of alkaline aqueous solutions on the properties of bentonite was investigated to evaluate the performance of bentonitic engineered barriers when contacted with alkaline groundwater. Batch and hydraulic conductivity tests were conducted on Na-bentonite using six different alkaline aqueous solutions. For the batch tests, almost no change in the montmorillonite fraction of the bentonite was observed after reacting with alkaline solutions (pH = 8.4–13.1), regardless of the solution type. On the other hand, aluminosilicate minerals (e.g., albite) were dissolved and secondary minerals (e.g., anorthite) were formed in alkaline NaOH solutions (pH > 13). The cation (Ca or Na) concentration primarily affected the swelling properties of bentonite rather than the pH of the solution, which was comparable to the results of the hydraulic conductivity tests. For the Ca solutions, the hydraulic conductivity of the bentonite specimen to the 0.02 mol/L Ca(OH)2 solution (6.5 × 10?9 cm/s) was approximately an order of magnitude lower than that of the bentonite specimen to the 0.02 mol/L Ca(OH)2 + 1 mol/L CaCl2 solution (5.0 × 10?8 cm/s), whereas the hydraulic conductivity to the 0.02 mol/L Ca(OH)2 + 1 mol/L CaCl2 solution (pH = 11.3) (5.0 × 10?8 cm/s) was slightly higher than that to the 1 mol/L CaCl2 solution (pHi = 8.4) (4.4 × 10?8 cm/s). For the NaOH solutions with pH > 13, the hydraulic conductivity of the bentonite specimen decreased with increasing Na concentration, suggesting that the effect of Na concentration was more dominant than that of permeant pH.  相似文献   

11.
Effective soil thermal conductivity (λ eff) describes the ability of a multiphase soil to transmit heat by conduction under unit temperature gradient. It is a critical parameter for environmental science, earth and planetary science, and engineering applications. Numerous models are available in the literature, but their applicability is generally restricted to certain soil types or water contents (θ). The objective of this study was to develop a new model in the similar form of the Johansen 1975 model to simulate the λ eff(θ) relationship of soils of various soil textures and water contents. An exponential type model with two parameters is developed and a new function for calculating dry soil thermal conductivity is presented. Performance of the new model and six other normalized models were evaluated with published datasets. The results show that the new model is able to well mimic λ eff(θ) relationship of soils from sand to silt loam and from oven dry to full saturation. In addition, it has the best performance among the seven models under test (with root-mean-square error of 0.059 W m?1 °C?1, average deviations of 0.0009 W m?1 °C?1, and Nash–Sutcliffe efficiency of 0.994). The new model has potential to improve the reliability of soil thermal conductivity estimation and be incorporated into numerical modeling for environmental, earth and engineering studies.  相似文献   

12.
In this paper, the shear strength of saturated pure sand and sand–silt mixture is evaluated by monotonic undrained triaxial tests that were carried out on reconstituted specimens at same relative densities and a constant confining pressure (σ 3?=?300 kPa). The test results were used to conclude on the effect of low non-plastic contents (0–20 %) and grading characteristics on the liquefaction resistance of the sand. The test results indicate that the undrained residual strength reduced with the increase of non-plastic fine content. Also, shear strength of gap-graded sand mixed with low non-plastic fine content increases with decrease in effective size (D 50). In other words, in this state, we can use the D 50 as a parameter to control of silty sand’s undrained resistance. Besides, the undrained residual strength of pure sand specimens with same effective size increases due to increase of coefficient of uniformity (C u).  相似文献   

13.
In this study, the effects of salinity of infiltrating solutions on the swelling strain, compressibility, and hydraulic conductivity of compacted GMZ01 Bentonite were investigated. After swelling under vertical load using either distilled water or NaCl solutions with concentrations of 0.1, 0.5 M, and 1 M, laboratory oedometer tests were conducted on the compacted GMZ01 Bentonite. Based on the oedometer test results, hydraulic conductivity was determined using the Casagrande’s method. Results show that the swelling strain of highly compacted GMZ01 Bentonite decreases as the concentration of NaCl solution increases. The compression index C c * increases and then turns to decrease with an increase in the vertical stress or a decrease in the void ratio for different solutions, and the C c * decreases as the concentration of NaCl solution increases. The secondary consolidation coefficient C α increases linearly with the increase of the compression index C c * . Furthermore, a bi-linear relationship between the swelling index C s * and the secondary consolidation coefficient C α can be characterized clearly. The hydraulic conductivity increases as the concentration of NaCl solution increases, however, this increase can be prevented if a high confining stress is applied.  相似文献   

14.
We estimated CO2 and CH4 emissions from mangrove-associated waters of the Andaman Islands by sampling hourly over 24 h in two tidal mangrove creeks (Wright Myo; Kalighat) and during transects in contiguous shallow inshore waters, immediately following the northeast monsoons (dry season) and during the peak of the southwest monsoons (wet season) of 2005 and 2006. Tidal height correlated positively with dissolved O2 and negatively with pCO2, CH4, total alkalinity (TAlk) and dissolved inorganic carbon (DIC), and pCO2 and CH4 were always highly supersaturated (330–1,627 % CO2; 339–26,930 % CH4). These data are consistent with a tidal pumping response to hydrostatic pressure change. There were no seasonal trends in dissolved CH4 but pCO2 was around twice as high during the 2005 wet season than at other times, in both the tidal surveys and the inshore transects. Fourfold higher turbidity during the wet season is consistent with elevated net benthic and/or water column heterotrophy via enhanced organic matter inputs from adjacent mangrove forest and/or the flushing of CO2-enriched soil waters, which may explain these CO2 data. TAlk/DIC relationships in the tidally pumped waters were most consistent with a diagenetic origin of CO2 primarily via sulphate reduction, with additional inputs via aerobic respiration. A decrease with salinity for pCO2, CH4, TAlk and DIC during the inshore transects reflected offshore transport of tidally pumped waters. Estimated mean tidal creek emissions were ~23–173 mmol m?2 day?1 CO2 and ~0.11–0.47 mmol m?2 day?1 CH4. The CO2 emissions are typical of mangrove-associated waters globally, while the CH4 emissions fall at the low end of the published range. Scaling to the creek open water area (2,700 km2) gave total annual creek water emissions ~3.6–9.2?×?1010 mol CO2 and 3.7–34?×?107 mol CH4. We estimated emissions from contiguous inshore waters at ~1.5?×?1011 mol CO2?year?1 and 2.6?×?108 mol CH4?year?1, giving total emissions of ~1.9?×?1011 mol CO2?year?1 and ~3.0?×?108 mol CH4?year?1 from a total area of mangrove-influenced water of ~3?×?104 km2. Evaluating such emissions in a range of mangrove environments is important to resolving the greenhouse gas balance of mangrove ecosystems globally. Future such studies should be integral to wider quantitative process studies of the mangrove carbon balance.  相似文献   

15.
In this study, an investigation was performed to determine if lime-stabilized sand–bentonite mixtures are appropriate for the construction of sanitary landfills liners. For this aim, the hydraulic conductivity tests were conducted in the laboratory on sand–bentonite mixtures and lime-stabilized sand–bentonite mixtures to evaluate the effect of wetting–drying cycles. The hydraulic conductivity tests were performed to see if their hydraulic conductivities are affected by wetting–drying cycles. First series of specimens have been prepared as a mixture of sand and bentonite only. In the first series of specimens, sand was mixed with bentonite in proportions of 20, 30, 40, and 50 %. In the second series of the specimens, lime in proportions of 1, 2 and 3 % by weight was added to the mixtures of sand–bentonite in proportions of 20, 30, 40, and 50 %. From the results of the tests, it was observed that while optimum water content increased, maximum dry density decreased with addition of lime to the sand–bentonite mixtures. Generally, the hydraulic conductivity increased with the addition of lime to the mixtures but at low percentages of lime (1–2 %), however, slight decreases in k were recorded. It was also observed that the wetting–drying cycles on the permeability test indicate cure effect on specimens with addition of lime which resulted in decreased the hydraulic conductivity.  相似文献   

16.
The Tongue Creek watershed lies on the south flank of Grand Mesa in western Colorado, USA and is a site with 1.5 km of topographic relief, heat flow of 100 mW/m2, thermal conductivity of 3.3 W m–1 °C–1, hydraulic conductivity of 10-8 m/s, a water table that closely follows surface topography, and groundwater temperatures 3–15°C above mean surface temperatures. These data suggest that convective heat transport by groundwater flow has modified the thermal regime of the site. Steady state three-dimensional numerical simulations of heat flow, groundwater flow, and convective transport were used to model these thermal and hydrological data. The simulations provided estimates for the scale of hydraulic conductivity and bedrock base flow discharge within the watershed. The numerical models show that (1) complex three-dimensional flow systems develop with a range of scales from tens of meters to tens of kilometers; (2) mapped springs are frequently found at locations where contours of hydraulic head indicate strong vertical flow at the water table, and; (3) the distribution of groundwater temperatures in water wells as a function of surface elevation is predicted by the model.  相似文献   

17.
The Ospino-Kitoi and Kharanur ultrabasic massifs represent the northern and southern ophiolite branches respectively of the Upper Onot ophiolitic nappe and they are located in the southeastern part of the Eastern Sayan(SEPES ophiolites).Podiform chromitites with PGE mineralization occur as lensoid pods within dunites and rarely in harzburgites or serpentinized peridotites.The chromitites are classified into type I and type Ⅱ based on their Cr~#.Type I(Cr~# = 59-85) occurs in both northern and southern branches,whereas type Ⅱ(Cr~# = 76-90) occurs only in the northern branch.PGE contents range from ∑PGE 88-1189 ppb,Pt/Ir0.04-0.42 to ∑PGE 250-1700 ppb,Pt/Ir 0.03-0.25 for type I chromitites of the northern and southern branches respectively.The type Ⅱ chromitites of the northern branch have ∑PGE contents higher than that of type Ⅰ(468-8617 ppb,Pt/Ir 0.1-0.33).Parental melt compositions,in equilibrium with podiform chromitites,are in the range of boninitic melts and vary in Al_2O_3,TiO_2 and FeO/MgO contents from those of type I and type Ⅱ chromitites.Calculated melt compositions for type Ⅰ chromitites are(Al_2O_3)_(melt) = 10.6—13.5 wt.%,(TiO_2)_(melt) = 0.01-0.44 wt.%,(Fe/Mg)_(melt) = 0.42-1.81;those for type Ⅱ chromitites are:(Al_2O_3)_(melt) = 7.8-10.5 wt.%,(TiO_2)_(melt) = 0.01-0.25 wt.%,(Fe/Mg)_(melt) = 0.5-2.4.Chromitites are further divided into Os-Ir-Ru(Ⅰ) and Pt-Pd(Ⅱ) based on their PGE patterns.The type Ⅰ chromitites show only the Os-Ir-Ru pattern whereas type Ⅱ shows both Os-Ir-Ru and Pt-Pd patterns.PGE mineralization in type Ⅰ chromitites is represented by the Os-Ir-Ru system,whereas in type Ⅱ it is represented by the Os-Ir-Ru-Rh-Pt system.These results indicate that chromitites and PGE mineralization in the northern branch formed in a suprasubduction setting from a fluid-rich boninitic melt during active subduction.However,the chromitites and PGE mineralization of the southern branch could have formed in a spreading zone environment.Mantle peridotites have been exposed in the area with remnants of mantle-derived reduced fluids,as indicated by the occurrence of widespread highly carbonaceous graphitized ultrabasic rocks and serpentinites with up to 9.75 wt.%.Fluid inclusions in highly carbonaceous graphitized ultrabasic rocks contain CO,CO_2,CH4,N_2 and the δ~(13)C isotopic composition(-7.4 to-14.5‰) broadly corresponds to mantle carbon.  相似文献   

18.
Collapsible soils are problematic by nature. They undergo collapse or sudden settlement or subsidence under a given stress when their water content is increased. Collapse is characterised by collapse potential expressed as ΔH/H x 100, where ΔH is collapse compression. The amount of stress applied and the water content at the time of collapse govern the amount of collapse. In other words, collapse potential depends upon the amount of stress and the water content. Loess and other wind-blown silts are examples of collapsible soils. This paper presents a parametric study on the collapse behaviour of a lateritic soil. Remoulded specimens of a lateritic soil passing through a 425 µm sieve were compacted in 1-D consolidometer or oedometer at a density of 13 kN/m3 for studying collapse under varied initial moisture contents and initial surcharge pressures. Collapse compression of the samples was induced by saturating the specimens with water contents corresponding to 100% degree of saturation. After collapse occurred, the 1-D consolidation tests were continued up to an applied stress of 160 kPa. Collapse behaviour was studied for the applied initial pressures (σi) of 10, 20 and 40 kPa and for the initial water contents (wi) of 5%, 10%, 15% and 20%. Collapse compression and collapse potential decreased with increasing wi for all σi.  相似文献   

19.
Optimization of calcium-based bioclogging and biocementation of sand   总被引:1,自引:0,他引:1  
Bioclogging and biocementation can be used to improve the geotechnical properties of sand. These processes can be performed by adsorption of urease-producing bacterial cells on the sand grain surfaces, which is followed by crystallization of calcite produced from the calcium salt and urea solution due to bacterial hydrolysis of urea. In this paper, the effect of intact cell suspension of Bacillus sp. strain VS1, suspension of the washed bacterial cells, and culture liquid without bacterial cells on microbially induced calcite precipitation in sand was studied. The test results showed that adsorption/retention of urease activity on sand treated with washed cells of Bacillus sp. strain VS1 was 5–8 times higher than that treated with culture liquid. The unconfined compressive strength of sand treated with the suspension of washed cells was 1.7 times higher than that treated with culture liquid. This difference could be due to fast inactivation of urease by protease which was present in the culture liquid. The adsorption of bacterial cells on sand pretreated with calcium, aluminum, or ferric salts was 29–37 % higher as compared with that without pretreatment. The permeability of sand varied with the content of precipitated calcium. For bioclogging of sand, the content of precipitated calcium had to be 1.3 % (w/w) or higher. The shear strength of biotreated sand was also dependent on the content of precipitated calcium. To achieve an unconfined compressive strength of 1.5 MPa or higher, the content of precipitated calcium in the treated sand had to be 4.2 % (w/w) or higher. These data can be used as the reference values for geotechnical applications such as bioclogging for reducing the permeability of sand and biocementation for increasing the shear strength of soil.  相似文献   

20.
Absrtract This paper investigates the potential use of sand–attapulgite (palygorskite) mixtures as a landfill liner. The sand and attapulgite clay used in this study were brought from Wahiba (eastern Oman) and Al-Shuwamiyah (southern Oman), respectively. Initially the basic properties of the sand and clay were determined. Then the attapulgite clay was added to the sand at 5, 10, 20 and 30% by dry weight of the sand. The sand–attapulgite clay mixtures were subjected to mineralogical, chemical, microfabric and geotechnical analyses. The X-ray diffraction (XRD) qualitative analysis showed that attapulgite is the major clay mineral. The chemical compounds, exchangeable cations and cation exchange capacity (CEC) for the␣samples were determined. The CEC for the sand–clay mixtures is low but increases with the increase in clay content. The scanning electron microscope (SEM) examination showed that the addition of clay developed coating between and around the sand grains which results in filling the voids and reducing the hydraulic conductivity of the sand–clay mixtures. The hydraulic conductivity values for the pure clay and sand + 30% clay mixture prepared at 2% above optimum water content are slightly higher than hydraulic conductivity requirements for landfill liners but can be acceptable. The geotechnical study which included grain size distribution, Atterberg limits, specific gravity, compaction, hydraulic conductivity and shear strength tests showed that the sand+30% clay mixture prepared at 2% above optimum water content can be considered to satisfy the requirements for landfill liners. For all sand–clay mixtures no swelling was recorded and the addition of clay to the sand improved the shear strength.  相似文献   