首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The characteristics of the strong ground motion accelerograms from the 1999 Kocaeli earthquake are investigated in detail in this study. The emphasis is on the comparison of the response spectra for the fault normal (FN) and fault parallel (FP) components of the ground motions. The results show that the near-fault records with directivity effects characterize themselves with increased base shear demands rather than increased displacement demands for both the FN and FP components and a narrower velocity sensitive region for the FN component. This study also shows that the effectiveness of base isolation may vary from site to site and for a given site, from component to component. The site effects in the Marmara region during the 1999 Kocaeli earthquake are examined. Site amplifications are predicted by the classical spectral ratio (CSR) and the receiver function (RF) methods. The CSR method gives higher estimates for the site amplifications compared to the RF method and is in better conformity with the observed damage during the Kocaeli earthquake. The districts of Istanbul that are especially susceptible to site amplification hazard are determined. It is apparent from the results that the site amplification hazard risk is the highest for Avcilar and Bakirkoy districts. This study also shows that for sites which have the risk of soil amplification for long-period structures, liquefaction may not be beneficial as a natural base isolator, and may result in shifting the eigenperiod of the low- and mid-rise structures to the critical periods with high site amplifications. This may be especially the case for Avcilar and Bakirkoy districts. In Fatih, Bakirkoy, and Cekmece districts, the predominant period of the ground motion is calculated to be very close to the eigenperiods of the typical residential buildings. Therefore, these three districts are expected to experience heavier damages in future earthquakes due to resonance effects.  相似文献   

2.
This paper presents a comparison of near-fault and far-fault ground motion effects on geometrically nonlinear earthquake behavior of suspension bridges. Bo?azi?i (The First Bosporus) and Fatih Sultan Mehmet (Second Bosporus) suspension bridges built in Istanbul, Turkey, are selected as numerical examples. Both bridges have almost the same span. While Bo?azi?i Suspension Bridge has inclined hangers, Fatih Sultan Mehmet Suspension Bridge has vertical hangers. Geometric nonlinearity including P-delta effects from self-weight of the bridges is taken into account in the determination of the dynamic behavior of the suspension bridges for near-fault and far-fault ground motions. Near-fault and far-fault strong ground motion records, which have approximately identical peak ground accelerations, of 1999 Chi-Chi, 1999 Kocaeli, and 1979 Imperial Valley earthquakes are selected for the analyses. Displacements and internal forces of the bridges are determined using the finite element method including geometric nonlinearity. The displacements and internal forces obtained from the dynamic analyses of suspension bridges subjected to each fault effect are compared with each other. It is clearly seen that near-fault ground motions are more effective than far-fault ground motion on the displacements and internal forces such as bending moment, shear force and axial forces of the suspension bridges.  相似文献   

3.
The influence of local geologic and soil conditions on the intensity of ground shaking is addressed in this study. The amplification of the ground motion due to local site effects resulted in severe damage to dwellings in the Bam area during the 2003 Bam Earthquake. A unique set of strong motion acceleration recordings was obtained at the Bam accelerograph station. Although the highest peak ground acceleration recorded was the vertical component (nearly 1 g), the longitudinal component (fault-parallel motion) clearly had the largest maximum velocity as well as maximum ground displacement. Subsurface geotechnical and geophysical (down-hole) data in two different sites have been obtained and used to estimate the local site condition on earthquake ground motion in the area. The ground response analyses have been conducted considering the nonlinear behavior of the soil deposits using both equivalent linear and nonlinear approaches. The fully nonlinear method embodied in FLAC was used to evaluate the nonlinear soil properties on earthquake wave propagation through the soil layer, and compare with the response from the equivalent linear approach. It is shown that thick alluvium deposits amplified the ground motion and resulted in significant damage in residential buildings in the earthquake stricken region. The comparison of results indicated similar response spectra of the motions for both equivalent and nonlinear analyses, showing peaks in the period range of 0.3–1.5 s. However, the amplification levels of nonlinear analysis were less than the equivalent linear method especially in long periods. The observed response spectra are shown to be above the NEHRP building code design requirements, especially at high frequencies.  相似文献   

4.
Residential RC framed structures suffered heavily during the 2001 Bhuj earthquake in Gujarat, India. These types of structures also saw severe damage in other earthquakes such as the 1999 Kocaeli earthquake in Turkey and 921 Ji-Ji earthquake in Taiwan. In this paper the seismic response of residential structures was investigated using physical modelling. Idealised soft storey and top heavy, two degrees of freedom (2DOF) portal frame structures were developed and tested on saturated and dry sand models at 25 g using the Schofield Centre 10-m Beam Centrifuge. It was possible to recreate observed field behaviour using these models. As observed in many of the recent earthquakes, soft storey structures were found to be particularly vulnerable to seismic loads. Elastic response spectra methods are often used in the design of simple portal frame structures. The seismic risk of these structures can be significantly increased due to modifications such as removal of a column or addition of heavy water tanks on the roof. The experimental data from the dynamic centrifuge tests on such soft storey or top-heavy models was used to evaluate the predictions obtained from the response spectra. Response spectra were able to predict seismic response during small to moderate intensity earthquakes, but became inaccurate during strong earthquakes and when soil structure interaction effects became important. Re-evaluation of seismic risk of such modified structures is required and time domain analyses suggested by building codes such as IBC, UBC or NEHRP may be more appropriate.  相似文献   

5.
Earthquake damages are assessed based on a holistic approach using structural as well as non-structural factors to model earthquake damage distributions with Decision Tree Techniques, using the Answer Tree program and the damage data from recent major earthquakes in Turkey. The damage dataset consists of approximately 9,400 buildings that were surveyed to evaluate the factors affecting building damage after Erzincan [1992], Dinar [1995], and Kocaeli [1999] earthquakes. The earthquake damage is defined as the dependent variable, while earthquake magnitude (M), intensity (I) in the city, peak ground acceleration (PGA) in each city, epicenter distance (ED), building types (BT), number of storeys (NS), presence of soft storey (SS), building position (BP) on the site, and site conditions (SC) are independent variables in the proposed model. The damage level (DL) was classified with respect to red, yellow, and green codes. The main purpose was (1) to identify the factors controlling building damage during earthquakes; (b) to determine the most significant factor; (c) to evaluate the effects of different factors for different earthquakes; (d) to develop damage distribution models for different subgroups based on the Decision Tree Techniques.
Atilla AnsalEmail:
  相似文献   

6.
7.
An earthquake of magnitude 7.2 on the Richter scale occurred on 12 November 1999 in the Düzce-Bolu region of Turkey. The region was also hit approximately 3 months before during the devastating Kocaeli earthquake of 17 August 1999. Besides high casualties and damage to various engineering structures and buildings, slope and embankment failures on the highway and the country roads occurred. In this study, the authors are concerned with the back-analysis of an embankment failure that occurred on the four lanes E-5 highway connecting Ankara to Gstanbul at Bakacak in the Bolu Province during the 1999 Düzce earthquake. Both pseudo-dynamic and dynamic limiting equilibrium methods are used to back analyse the conditions for the initiation of failure and also displacement responses of the embankment during the earthquake shaking. After having given a brief summary of the investigations on the post-failure state, the geology and geotechnical characteristics of the site, and the dynamic limiting equilibrium method developed and used for analyses are described. The results of the back-analysis based on a pseudo-dynamic approach, revealed that the maximum ground acceleration to initiate the failure of the embankment was probably about 0.125 g. On the other hand, the application of a method for computing the displacement and velocity responses of the failed embankment showed that the failure was possible when the embankment was subjected to ground accelerations similar to that recorded at the Düzce station. In addition, the computations also revealed that the time history of accelerations could be very important for the failure of slopes and embankments.  相似文献   

8.
The Tsunami of August 17, 1999 in Izmit Bay,Turkey   总被引:2,自引:0,他引:2  
Altinok  Y.  Tinti  S.  Alpar  B.  Yalçiner  A. C.  Ersoy  Ş  Bortolucci  E.  Armigliato  A. 《Natural Hazards》2001,24(2):133-146
The Kocaeli 1999 Earthquake with an Mw = 7.4 caused major hazards throughout the NW of Turkey from Tekirdag to Bolu. Historical data indicates that some of the earthquakes around Izmit Bay have caused tsunamis. In this study, tsunami research for the Kocaeli 1999 Earthquake has been made also taking into consideration historical data. In this research more than about 70 data at 35 localities have been used to determine the tsunami evidences in the bay. Coastal observations indicated runups which were ranging from 1 to 2.5 m along the shores. However, the wave runups are more complex along the south coast due to the presence of coastal landslides (Deirmendere, Halidere, Ulasli, Karamürsel) and subsided areas (Kavakli to Yeniköy) along the shore. West of Yalova, evidence of tsunami rapidly diminished. In addition, possible tectonic mechanism has been determined by using 33 single-channel high-resolution digital seismic reflection profiles which were acquired following the Kocaeli 1999 Earthquake. As a result it has been determined that the Kocaeli Earthquake has created tsunami in Izmit Bay.  相似文献   

9.
Ground motion records obtained in recent major strong earthquakes have provided evidence that ground motions recorded near the near-fault regions differ in many cases from those observed further away from the seismic source. As the forward directivity and fling effect characteristics of the near-fault ground motions, they have the potential to cause more considerable damage to structures during an earthquake. Therefore, understanding the influence of near-fault ground motions on the performance of structures is critical to mitigate damage and perform effective response. This paper presents results of a study aimed at evaluating the effects of near-fault and far-fault ground motions on seismic performance of concrete gravity dams including dam-reservoir-foundation interaction. Koyna gravity dam is selected as a numerical application. Four different near-fault ground motion records with an apparent velocity pulse are used in the analyses. The earthquake ground motions recorded at the same site from other events that the epicenter far away from the site are employed as the far-fault ground motions. The seismic performance evaluation method based on the demand-capacity ratio, the cumulative overstress duration and the spatial extent of overstressed regions is presented. The concrete damaged plasticity model including the strain hardening or softening behavior is employed in nonlinear analyses. Nonlinear seismic damage analyses of the selected concrete dam subjected to both near-fault and far-fault ground motions are performed. The results obtained from the analyses show the effects of near-fault ground motions on seismic performance of concrete gravity dams and demonstrate the importance of considering the near-fault ground excitations.  相似文献   

10.
极震区岩体地震动力破坏若干问题探讨   总被引:2,自引:0,他引:2  
汶川地震时极震区产生了严重的地震地质灾害,其中强烈地震动造成的岩体动力破坏是造成灾害的根本原因。从极震区含义、地震动特征、岩体地震动力破坏概念、地震松动岩体和方法论等方面初步探讨了极震区岩体地震动力破坏问题。极震区是未来地震的潜在震源区,区内的地震属于直下型。极震区地震动具有不同于非极震区的地震动特征,岩体地震动力破坏的复合性特点就是地震动的不确定性造成的。对极震区岩体动力破坏概念的理解应考虑地震动的特点。地震松动岩体是极震区地震动造成的一种特殊破坏类型,是形成震害次生灾害的重要原因。岩体工程地质力学等学科的思想方法和技术手段为研究极震区岩体地震动力破坏这一命题提供了良好的基础,预测和评价极震区因岩体动力破坏造成的工程震害和地质灾害,减轻和预防未来地震时的灾害损失,是极震区岩体地震动力破坏研究的目标和方向。  相似文献   

11.
On October 23, 2011, a magnitude of Mw 7.2 earthquake struck the Van province in eastern Turkey which caused approximately 600 life loss and 4,000 injured people. Although the recorded peak ground accelerations were relatively low (0.15–0.2 g) compared with that of other recent destructive Turkish earthquakes and the code-based design response spectrum, a large number of reinforced concrete buildings with 4–6 stories and non-engineered masonry buildings were either heavily damaged or collapsed in the region. Based on the post-earthquake technical inspections, the goal of this paper is to introduce major reasons for structural damages in the disaster area and to discuss these failures along with the approaches given in the design code which is renewed after August 17, 1999 Marmara Earthquake. Some remarkable lessons learned from earthquake-induced failures and damages specific to building construction techniques are presented in this paper.  相似文献   

12.
Within the framework of the performance based earthquake engineering, site specific earthquake spectra for Van province has been obtained. It is noteworthy that, in probabilistic seismic hazard assessment, as a first stage data from geological studies and records from the instrumental period were compiled to make a seismic source characterization for the study region. The probabilistic seismic hazard curves were developed based on selected appropriate attenuation relationships, at rock sites, with a probability of exceedance 2, 10 and 50% in 50 yrs period. The obtained results are compared with the spectral responses proposed for seismic evaluation and retrofit of building structure in Turkish Earthquake Code (2007), section 7. The acceleration response spectrums obtained from probabilistic seismic hazard analysis are matched to adjust earthquake accelerograms recorded during the 2011 Van earthquakes by using SeismoMatch v2.0 software. The aim of this procedure is to obtain a set of reasonable earthquake input motions for the seismic evaluation of existing buildings.  相似文献   

13.
Avcılar is the suburb of Istanbul that was most heavily damaged during the August 17, 1999 Mw 7.4 Izmit earthquake. Strong ground motion caused fatalities and damage in Avcılar despite being 90 km from the epicenter. We deployed five portable seismograph stations equipped with Reftek 24-bit recorders and L4C-3D seismometers for 2 months, in order to understand why the local site response was different from elsewhere in Istanbul. A reference station was placed on a hard rock site, and the remaining four stations were placed on other geological units, in areas that had experienced varying levels of damage. We calculated frequency-dependent ground amplification curves by taking the ratios of the spectra at soft and hard rock sites. We obtained similar site response curves for most earthquakes at each site in the frequency range of 0.3–1.6 Hz, and observed no significant site amplification beyond 2.0 Hz at any site. The overall characteristics of the recorded S-waveforms and our modeling of the calculated site amplification curves are consistent with amplification as a result of trapping of seismic energy within a 100–150 m thick, low-velocity subsurface layer. We also review the applicability of microtremor measurements to estimate local site effects at Avcılar. For these data, we used ratios of spectra of horizontal to vertical components to obtain each site response. These results are compared with standard spectral ratios. These microtremor measurements provide consistent estimates of the amplification at most sites at the higher end of the frequency band, namely above 1 Hz. The results from both methods indeed agree well in this part of the frequency band. However, the microtremor method fails to detect amplification at lower frequencies, namely <1.0 Hz.  相似文献   

14.
A microzonation study is performed as a part of the Zeytinburnu Pilot Project within the framework of the Earthquake Master Plan for Istanbul to determine the effects of local soil conditions on the earthquake forces that will act on structures. For this purpose, detailed geological and geotechnical studies are conducted at the site, a geological map which demonstrates the local geological features of the site is prepared, and the site is classified with respect to the dynamic behaviour based on the data gathered from the soil borings. In order to investigate the effects of local soil conditions on the dynamic behaviour, site response analyses are performed with the computer code EERA by utilizing the findings of field and laboratory investigations. The behaviour of the region during a probable earthquake is investigated through one dimensional response analyses and microzonation maps are prepared with respect to ground shaking intensity in accordance with the new microzonation manual [Ansal, A., Laue, J., Buchheister, J., Erdik, M., Springman, S., Studer, J., and Koksal, D., 2004. “Site characterization and site amplification for a seismic microzonation study in Turkey” 11th Int. Conference on Soil Dynamics and Earthquake Engineering and 3rd Earthquake Geotechnical Engineering, San Francisco; Studer, J. and Ansal, A., 2004. Belediyeler için Sismik Mikrobölgeleme El Kitabı, Araştırma Raporu, Afet İşleri Genel Müdürlüğü, Bayındırlık ve İskan Bakanlığı, Afet Risk Yönetimi Dünya Enstitüsü].  相似文献   

15.
The 1994 Northridge earthquake (Mw = 6.7) triggered extensive rock slope failures in Pacoima Canyon, immediately north of Los Angeles, California. Pacoima Canyon is a narrow and steep canyon incised in gneissic and granitic rocks. Peak accelerations of nearly 1.6 g were recorded at a ridge that forms the left abutment of Pacoima Dam; peak accelerations at the bottom of the canyon were less than 0.5 g, suggesting the occurrence of topographic amplification. Topographic effects have been previously suggested to explain similarly high ground motions at the site during the 1971 (Mw = 6.7) San Fernando earthquake. Furthermore, high landslide concentrations observed in the area have been attributed to unusually strong ground motions rather than higher susceptibility to sliding compared with nearby zones. We conducted field investigations and slope stability back-analyses to confirm the impact of topographic amplification on the triggering of landslides during the 1994 earthquake. Our results suggest that the observed extensive rock sliding and falling would have not been possible under unamplified seismic conditions, which would have generated a significantly lower number of areas affected by landslides. In contrast, modelling slope stability using amplified ground shaking predicts slope failure distributions matching what occurred in 1994. This observation confirms a significant role for topographic amplification on the triggering of landslides at the site, and emphasises the need to select carefully the inputs for seismic slope stability analyses.  相似文献   

16.
Site response analysis is crucial to define the seismic hazard and distribution of damage during earthquakes. The equivalent-linear (EQL) is a numerical method widely investigated and used for site response analysis. Because several sources of uncertainty are involved in this type of analysis, parameters defining the numerical models need to be identified from in-situ measurements. In this paper, a Bayesian inference method to estimate the expected values and covariance matrix of the model parameters is presented. The methodology uses data from downhole arrays recorded during earthquakes. Two numerical applications show the good performance and prediction capabilities of the proposed approach.  相似文献   

17.
The seismic observation network in Shiga prefecture iscomposed of four systems.All the observation data obtained were used to estimatethe dynamic characteristicsof the surface soils around the lake and the seismichazard for Hikone City. Since1995, 21 records have been obtained at the USP site ofwhich those for the 1999Shigaken-Hokubu Earthquake and 1999 Wakayarnaken-HokubuEarthquake wereused in this study. Transfer functions of the surfacesoil in each ward of ShigaPrefecture based on the Mt. Kojin site (KJY), whichhas relatively hard soil, werecalculated from the records of the two earthquakes.Assuming a scenario earthquakeat the Hyakusaiji fault close to Hikone City, maximumground motions were obtainedfor 15 city blocks in order to establish a damageestimation for that city. The numberof collapsed wooden houses and the damage ratiowere calculated based on the distributionof construction of wooden houses by year. Blockswith a larger ratio of old, wooden housesin Hikone showed a close correlation with blockswith a large ratio of aged persons inthem, indicative that weak persons, such as theelderly, may find themselves in a severesituation during a natural disaster.  相似文献   

18.
回顾了1994年美国Northridge地震、1995年日本阪神地震、1999年土耳其Kocaeli地震、1999年台湾集集地震、2008年中国汶川地震、2010年智利Maule地震、2010~2011新西兰Darfield地震及余震、2011年东日本地震中大量的、不同类型的液化实例调查与研究,发现这些地震的液化具有以下特点:(1)罕见的特大地震(Mw9.0)使远离震中300~400 km的新近人工填土发生严重的大规模液化;(2)特大地震(Ms8.0、Mw8.8)使远离震中的低烈度Ⅴ~Ⅵ度地区发生严重液化;(3)海岸、河岸附近地区的新近沉积冲积、湖积土,填筑时间不到50年的含细粒、砂砾人工填土,容易发生严重液化;(4)天然的砂砾土层液化发生严重液化;(5)发生了深达20 m的土层液化现象;(6)松散土层液化后可以恢复到震前状态并再次发生液化;(7)高细粒(粒径≤75 ?m)含量≥50%或高黏粒(粒径≤5 ?m)含量≥25%的低-中塑性土严重液化,对介于类砂土与类黏土之间的过渡性态土,有时地表未见液化现象;(8)液化土层的深度较深或厚度较小时,容易出现地面裂缝而无喷砂现象;有较厚的上覆非液化土层时,场地液化不一定伴随地表破坏。液化实例证明,第四系晚更新世Q3地层可以发生严重液化;黏粒含量不是评价细粒土液化可能性的一个可靠指标;低液限、高含水率的细粒土易发生液化,采用塑性指数PI、含水率wc与液限LL之比作为细粒土液化可能性评价的指标是适宜的。综合Boulanger和Idriss、Bray和Sincio、Seed和Cetin等的液化实例调查与室内试验研究成果,建议细粒土液化可能性的评价准则如下:PI <12且wc/LL>0.85的土为易液化土,12<PI≤20和/wc/LL≥0.80的土为可液化土;PI >20或wc/LL<0.80的土为不液化土。  相似文献   

19.
Site response measurements provide information on the amplification of ground motions generated by local conditions. Recent studies of large destructive earthquakes have shown that damage during the earthquakes are often caused by the amplification of seismic waves in near-surface sedimentary layers. The estimation of site response is therefore critical, in order to evaluate the true seismic hazard potential of a given area. We investigated local site amplifications in the South Iceland Seismic Zone (SISZ). Nine digital seismographs were deployed, temporarily, in an area of approximately 400 km2, in the westernmost part of the SISZ. Among the 90 events recorded, 15 were used in this study, including a magnitude 3.1 (ML) event and selected aftershocks, which occurred in the northern outskirts of the village Hveragerdi. Single Station Spectral Ratios (SSSR) of the recorded earthquakes revealed some of the effects of local site conditions. Spectral amplification factors of 2–5 on average, can be expected in the SIL area, depending on the sediment type and thickness. Higher site amplifications occur in the southern part of the study region, where the thickest sedimentary cover is found. Spectral amplification, related to topographical effects, is observed at the bedrock reference station, Bjarnastadir. Standard Spectral Ratios (SSR), with respect to the bedrock reference station, Bjarnastadir, were also calculated for some stations, in order to compare the two spectral ratio results. The two methods show a good correlation at some stations, whereas at others they vary considerably. The comparison between the earthquake and ambient noise data, on the other hand, gave better correlation when the SSSR method is used.  相似文献   

20.
In this paper, we use the 12 May 2008 Wenchuan Earthquake as a background event for analyzing and applying the principles of site selection of emergency shelters for a disastrous earthquake. Based on field investigations and analyses of remote sensing imagery, we identified the distribution of active faults and the locations of co-seismic surface rupture zones—areas in which buildings are at risk of intensive damage. It is important that emergency shelters are located outside of such vulnerable areas. One of the lessons learned from the Wenchuan Earthquake is that high fatality rates occur in areas without life-saving shelters. The principles that underlie the selection of emergency shelter sites are as follows: (1) keep far away from active fault zones, with the distance depending on the characteristics of the fault, including the nature of hangingwall and footwall structures; (2) disaster-mitigation strategies should be developed as a multi-dimensional system for the management of natural hazards, human activities, and urban expansion, involving keeping away from vulnerable slopes and establishing an early-warning system; (3) the accessibility of mountainous regions must be considered, including establishing small emergency shelters that house large numbers of people and covering regions with an uneven distribution of villages; and (4) government and law-making agencies in China must establish new earthquake design codes for buildings, emphasizing the importance of public facilities (including schools, collective welfare institutions, and medical facilities) as emergency shelters during disastrous earthquakes. The site-selection process requires an interdisciplinary approach involving seismologists, engineers, environmental and social scientists, emergency management personnel, and government officials. The parameters upon which the above principles are based can be qualitatively determined, thereby providing a valuable initial database for further quantitative analysis. The preliminary results and knowledge gained in the present paper can be used as a decision-making tool to support the government in earthquake-recovery and reconstruction programs. We also discuss practical examples of site evaluation in regions that suffered heavy damage during the Wenchuan Earthquake.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号