首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Throughout the world, buildings are reaching the end of their design life and develop new pathologies that decrease their structural capacity. Usually the ageing process is neglected in seismic design or seismic risk assessment but may become important for older structures, especially, if they are intended to be in service even after they exceed their design life. Thus, a simplified methodology for seismic performance evaluation with consideration of performance degradation over time is presented, based on an extension of the SAC/FEMA probabilistic framework for estimating mean annual frequencies of limit state exceedance. This is applied to an example of an older three-storey asymmetric reinforced concrete building, in which corrosion has just started to propagate. The seismic performance of the structure is assessed at several successive times and the instantaneous and overall seismic risk is estimated for the near collapse limit state. The structural capacity in terms of the maximum base shear and the maximum roof displacement is shown to decrease over time. Consequently, the time-averaged mean annual frequency of violating the near-collapse limit state increases for the corroded building by about 10% in comparison to the typical case where corrosion is neglected. However, it can be magnified by almost 40% if the near-collapse limit state is related to a brittle shear failure, since corrosion significantly affects transverse reinforcement, raising important questions on the seismic safety of the existing building stock.  相似文献   

2.
Performance-Based Seismic Design is now widely recognized as the pre-eminent seismic design and assessment methodology for building structures. In recognition of this, seismic codes may require that buildings achieve multiple performance objectives such as withstanding moderate, yet frequently occurring earthquakes with minimal structural and non-structural damage, while withstanding severe, but rare earthquakes without collapse and loss of life. These objectives are presumed to be satisfied by some codes if the force-based design procedures are followed. This paper investigates the efficacy of the Eurocode 8 force-based design provisions with respect to RC frame building design and expected seismic performance. Four, eight, and 16-storey moment frame buildings were designed and analyzed using the code modal response spectrum analysis provisions. Non-linear time-history analyses were subsequently performed to determine the simulated seismic response of the structures and to validate the Eurocode 8 force-based designs. The results indicate the design of flexural members in medium-to-long period structures is not significantly influenced by the choice of effective member stiffness; however, calculated interstorey drift demands are significantly affected. This finding was primarily attributed to the code’s enforcement of a minimum spectral ordinate on the design spectrum. Furthermore, design storey forces and interstorey drift demand estimates (and therefore damage), obtained by application of the code force-based design procedure varied substantially from those found through non-linear time-history analysis. Overall, the results suggest that though the Eurocode 8 may yield life-safe designs, the seismic performance of frame buildings of the same type and ductility class can be highly non-uniform.  相似文献   

3.
Recent earthquakes, that stroked Italian regions in past decades (Umbria— Marche 1997; Molise 2002; L’Aquila 2009), pointed out the high vulnerability of reinforced concrete existing buildings causing severe damages in the structures and consequently life losses. This is mainly due to the fact that such structures were often built without reference to seismic actions or on the basis of old standard provisions. Nowadays in Italy, Public Authorities are requested to evaluate the seismic vulnerability of their building stock assessing the actual capacity of such structures, as a consequence of new hazard levels and seismic microzonation introduced by new standards. According to Eurocode 8 or Italian standard NTC 2008, the seismic analysis of existing reinforced concrete buildings can be performed by one of the established procedure (i.e. Linear Static Analysis LSA, Linear Dynamic Analysis LDA, Nonlinear Static Analysis NSA, Nonlinear Dynamic Analysis NDA), depending on the achieved knowledge level about the structural system and materials. In order to compare efficiency and differences of previously described approaches, a deep investigation was executed on a reinforced concrete existing building whose dynamic behaviour was evaluated by an experimental dynamic analysis. In such a way, updated models were obtained and adopted for seismic analysis performed by using linear and nonlinear approaches, taking into account the stiffness and strength contribution of masonry infill walls. It was so possible to get useful indications on the reliability and discrepancies of different modelling approaches as well as on the influence of masonry infills on the seismic response of existing r.c. buildings.  相似文献   

4.
Seismic behaviour of masonry buildings, built of low compressive strength units, is discussed. Although such materials have already been tested and approved for use from mechanical and thermal insulation point of view, the knowledge regarding their structural behaviour is still lacking. In order to investigate the resistance and deformation capacity of this particular type of masonry construction in seismic conditions, a series of eight walls and model of a two-storey full scale confined masonry building have been tested by subjecting the specimens to cyclic shear loads. All tests were conducted under a combination of constant vertical load and quasi static, cyclically imposed horizontal load. The behaviour of tested specimens was of typical shear type. Compared with the behaviour of plain masonry walls, the presence of tie-columns resulted into higher resistance and displacement capacity, as well as smaller lateral resistance degradation. The response of the model was determined by storey mechanism with predominant shear behaviour of the walls and failure mechanism of the same type as in the case of individual confined masonry walls. Adequate seismic behaviour of this particular masonry structural type can be expected under the condition that the buildings are built as confined masonry system with limited number of stories.  相似文献   

5.
Seismic hazard levels lower than those for design of new buildings have been permitted for seismic evaluation and retrofit of existing buildings due to the relatively short remaining lifespans. The seismic hazard reduction enables costeffective seismic evaluation and retrofit of existing buildings with limited structural capacity. The current study proposes seismic hazard reduction factors for Korea, one of low to moderate seismicity regions. The seismic hazard reduction factors are based on equal probabilities of non-exceedance within different remaining building lifespans. A validation procedure is proposed to investigate equality of seismic risk in terms of ductility-based limit states using seismic fragility assessment of nonlinear SDOF systems, of which retrofit demands are determined by the displacement coefficient method of ASCE 41-13 for different target remaining building lifespans and corresponding reduced design earthquakes. Validation result shows that the use of seismic hazard reduction factors can be permitted in conjunction with appropriate lower bounds of the remaining building lifespans.  相似文献   

6.
As a result of rapid economic growth and urbanization in the past two decades,many tall buildings have been constructed in China Mainland,offering researchers and practitioners an excellent opportunity for research and practice in the field of structural engineering. This paper reviews progress by researchers throughout China Mainland on the seismic research of tall buildings,focusing on three major topics that impact the seismic performance of tall buildings. These are:(1) new types of steel-concrete composite structural members such as steel-concrete composite shear walls and columns,(2) earthquake resilient shear wall structures such as shear walls with replaceable structural components,self-centering shear walls and rocking walls,and(3) performance-based seismic design,including seismic performance index,performance level and design method. The paper concludes by presenting future research needs and directions in this field.  相似文献   

7.
Although modern seismic codes have undoubtedly led to safer structures, the seismic vulnerability of metropolitan areas is unavoidably governed by that of older buildings, which constitute the vast majority of the current building stock. Quite alarmingly, even relatively moderate intensity earthquakes have been proven capable of challenging their structural integrity, leading to severe damage or collapse. Therefore, there is an urgent need to assess the vulnerability of existing structures and to evaluate the efficiency of novel retrofit techniques. This paper studies experimentally the seismic performance of an existing three‐storey building, retrofitted through addition of shear walls. Emphasis is placed on the foundation of the shear walls, and two design alternatives are comparatively assessed: (a) conventional design according to current seismic codes and (b) ‘rocking isolation’ by reducing the size of the foundation. A series of reduced‐scale shaking table tests are conducted at the Laboratory of Soil Mechanics of the National Technical University of Athens. The physical model encompasses the structural system, along with the foundations, and the soil. The nonlinearity of structural members is simulated through specially designed and carefully calibrated artificial plastic hinges. The vulnerability of the original structure is confirmed, as it is found to collapse with a soft‐storey mechanism when subjected to moderate intensity shaking. The conventionally retrofitted structure is proven capable of sustaining larger intensity shaking, and the rocking‐isolated structure is shown to offer increased safety margins. Thanks to its inherent self‐centering mechanism, the rocking system is characterized by reduced permanent drifts. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
通过对某小区小高层住宅2种结构方案的综合讨论,分析了小高层住宅的合理结构型式,提出了设计建议可供工程设计参考。异型柱框架-剪力墙结构框架柱布置灵活、隐蔽性好,但其柱截面不规则、计算理论不成熟、抗震能力较差、构造措施不理想、而且建筑自振周期长,侧向位移大,难以用于较高的高层住宅和抗震烈度较高的地区;大开洞剪力墙结构受力明确、计算理论成熟,又有较为精确的计算程序,而且墙厚可以在规范允许的范围内减薄,从而进一步降低了工程造价。通过2种方案比较,认为大开洞剪力墙体系与异型柱框剪结构相比,配筋总量基本接近,但其侧移较小,具有较好的延性,可应用于小高层住宅和地震烈度较高地区并可取得显著经济效益。  相似文献   

9.
Seismic safety of low ductility structures used in Spain   总被引:1,自引:0,他引:1  
The most important aspects of the design, seismic damage evaluation and safety assessment of structures with low ductility like waffle slabs buildings or flat beams framed buildings are examined in this work. These reinforced concrete structural typologies are the most used in Spain for new buildings but many seismic codes do not recommend them in seismic areas. Their expected seismic performance and safety are evaluated herein by means of incremental non linear structural analysis (pushover analysis) and incremental dynamic analysis which provides capacity curves allowing evaluating their seismic behavior. The seismic hazard is described by means of the reduced 5% damped elastic response spectrum of the Spanish seismic design code. The most important results of the study are the fragility curves calculated for the mentioned building types, which allow obtaining the probability of different damage states of the structures as well as damage probability matrices. The results, which show high vulnerability of the studied low ductility building classes, are compared with those corresponding to ductile framed structures.  相似文献   

10.
An indexing method for rapid evaluation of the seismic vulnerability of infi lled RC frame buildings in Jordan is proposed. The method aims at identifying low and medium rise residential buildings as safe or in need of further detailed evaluation. Following a rapid visual screening, the building is assigned a Basic Capacity Index(BCI); fi ve performance modifi ers are identifi ed and multiplied by the BCI to arrive at the Capacity Index(CI) of the building. A Capacity Index lower than a limit CI value indicates that the screened building could experience moderate earthquake damage whereas a higher value implies that minor damage, if any, would take place. To establish the basic evaluation parameters; forty RC frame buildings were selected, designed and analyzed using static nonlinear analysis and incorporating the effect of infi ll walls. Effects of seismicity, local site conditions, horizontal irregularities(setbacks and re-entrant corners), vertical irregularities(soft story at ground fl oor level) and overhangs on the seismic performance of local buildings were examined. Assessment forms were designed and used to evaluate and rank 112 sample buildings. About 40% of the surveyed buildings were found to be in need of detailed evaluation to better defi ne their seismic vulnerabilities.  相似文献   

11.
The paper focuses on the seismic response of walls in dual (frame + wall) structures, with particular emphasis on shear behaviour. Although dual structures are widely used in earthquake-resistant medium-rise and high-rise buildings, the provisions of modern seismic codes regarding design of walls for shear are not fully satisfactory, particularly in the (common) case that walls of substantially different length form part of the same structure. Relevant provisions of the leading seismic codes are first summarised and their limitations discussed. Then an extensive parametric study is presented, involving two multistorey dual systems, one with identical walls, and one with walls with unequal length, designed to the provisions of Eurocode 8 for two different ductility classes (H and M). The walls of the same structures are also designed to other methods such as those used in New Zealand and Greece. The resulting different designs are then assessed by subjecting the structures to a suite of strong ground motions, carrying out inelastic time history analysis, and comparing the results against design action effects. It is found that although modern code procedures generally lead to satisfactory performance (differences among them do exist), the design of walls seems to be less appropriate in the case of unequal length walls. For this case a modified procedure is proposed, consisting of an additional factor to account for the relative contribution of walls of the same length to the total base and an improved envelope of wall shears along the height; this improved method seems to work better than the other procedures evaluated herein, but further calibration is clearly required.  相似文献   

12.
In the paper the seismic response of different variants of the three-story reinforced concrete frame structure SPEAR is compared. The basic structure is representative of building practice before the adoption of seismic codes. This structure has been compared with four modified variants, which were designed partly or completely in accordance with the Eurocode family of standards. For seismic assessment the practice-oriented nonlinear N2 method was used. The results demonstrate the low seismic resistance of buildings designed for gravity loads only. On the other hand, the advantages of new standards are clearly apparent. By taking into account the requirements of Eurocode 8 it is possible to ensure adequate strength, stiffness and ductility. By means of capacity design it is possible to ensure a global plastic mechanism. All these characteristics contribute to the high seismic resistance of structures designed according to Eurocode 8 and to their satisfactory behaviour during earthquakes.  相似文献   

13.
The results of shaking table tests of a series of 1:5 scale masonry building models have been used for the assessment of values of structural behavior factor q for masonry structures, seismic force reduction factors proposed for the calculation of design seismic loads by Eurocode 8, European standard for the design of structures for earthquake resistance. Six models have been tested, representing prototype buildings of two different structural configurations and built with two different types of masonry materials. The study indicated that the reduction of seismic forces for the design depends not only on the type of masonry construction system, but also on structural configuration and mechanical characteristics of masonry materials. It has been also shown that besides displacement and energy dissipation capacity, damage limitation requirement should be taken into account when evaluating the values of behavior factor. On the basis of analysis of experimental results a conclusion can be made, that the values at the upper limit of the proposed range of values of structural behavior factor q for unreinforced and confined masonry construction systems are adequate, if pushover methods are used and the calculated global ductility of the structure is compared with the displacement demand. In the case where elastic analysis methods are used and significant overstrength is expected, the proposed values are conservative. However, additional research and parametric studies are needed to propose the modifications.  相似文献   

14.
根据我国现行的建筑结构抗震规范,无论是新建建筑结构的抗震设计还是既有建筑结构的抗震评估与加固,均通过小震弹性承载力计算 抗震延性构造措施来达到"小震不坏、中震可修、大震不倒"的抗震设防目标(对于不规则且具有明显薄弱部位的建筑结构还需要进行罕遇地震作用下的弹塑性层间变形验算)。对于抗震延性构造措施不满足现行规范的既有建筑结构的评估、改建、扩建,如果仅通过小震弹性的承载力计算,显然无法达到"大震不倒"的目标。本文通过引入国际上先进的基于性能的结构抗震思想,以结构层间位移和结构构件变形作为性能目标,从定量上解决了既有钢筋混凝土建筑结构的抗震评估与加固问题。  相似文献   

15.
For earthquake action the new design provisions of Eurocode 8 are in the process of replacing the European national earthquake codes. The paper treats the design and behaviour of multi-storey structural walls in view of the new provisions. For structural walls the provisions of the Eurocode 8 are compared with those of a national code which it is going to replace. As the national code the current Swiss earthquake standard SIA 160 is chosen. Basic design rules of both codes are introduced and compared by means of examples comprising buildings which are regular in plan and elevation and which use structural walls for lateral resistance. The height of the buildings is varied from a from four to eight storeys. In the example, both the SIA and the Eurocode design provisions are based on the static equivalent force method, and a triangular distribution of the lateral force. However, most other design provisions differ between the two codes. The structures designed are modelled numerically and subjected to non-linear time-history analysis. At first, both the SIA and Eurocode designed structures are subjected to ground motions compatible to the design spectra in the respective codes. Then all structures are subjected to a recorded ground motion. The results are discussed in view of assumptions made at the design phase. Conclusions and recommendations are provided. © 1998 John Wiley & Sons, Ltd.  相似文献   

16.
分析了中美欧抗震设计中的水平地震作用问题。首先,比较了中美欧抗震规范中建筑物重要性、强度折减系数的差异,介绍了中国规范的底部剪力法、美国规范的等效侧向荷载法以及欧洲规范的侧向荷载法。然后对一多层框架结构,分别作为办公楼和医院,计算了不同设防烈度下、不同延性等级下的水平地震作用,并进行了比较分析,获得了3种规范关于水平地震作用的一些差异。  相似文献   

17.
梁斌  张海  姚新强  高武平  陈贺 《地震工程学报》2020,42(4):856-861,947
砖砌体结构是农村传统农居建筑的主要结构形式,如何精确评价其抗震能力具有重要的研究意义。目前既有传统农居中,20世纪80、90年代砖砌体结构仍是其重要的组成部分。为研究既有传统砖砌体结构的抗剪性能,首先对水泥砂浆、白灰砂浆、炉渣砂浆、黄泥砂浆4种典型砂浆开展抗压强度试验;然后对4种典型砂浆砌筑的砌体进行沿通缝抗剪强度试验,通过与传统老旧红砖砌体抗剪强度的平均值和公式值进行对比,对砌体抗剪强度计算公式进行修正后得到修正公式;最后对比修正值、标准值和设计值,对传统农居进行准确的砖砌体抗剪强度评估。本项研究主要为传统农居砖砌体结构的抗震性能评估、抗震加固以及抗震设计提供技术支持与科学依据。  相似文献   

18.
边缘约束构件对钢筋混凝土剪力墙抗震性能的影响   总被引:6,自引:1,他引:6  
钢筋混凝土剪力墙是高层建筑中的主要抗侧力构件,边缘约束情况是影响剪力墙抗震性能的一个重要因素。为研究边缘约束构件对钢筋混凝土剪力墙抗震性能的影响,本文进行了三片边缘约束情况不同的钢筋混凝土剪力墙的低周反复试验,并对试验结果进行了分析,分析内容包括:破坏形态、水平承载力、位移延性系数、刚度退化、抗震耗能能力等方面。研究结果表明,合理地设置边缘约束能够扩大塑性破坏区域,提高试件的水平承载力,改善其抗震耗能性能。研究进一步发现,边缘纵筋配筋率在提高试件的水平承载力,改善其抗震耗能性能和刚度退化程度方面影响显著,而边缘配箍率对抗震性能的贡献在本次试验分析中表现得并不明显。  相似文献   

19.
This study describes the seismic performance of an existing five storey reinforced concrete building which represents the typical properties of low-rise non-ductile buildings in Turkey. The effectiveness of shear walls and the steel bracings in retrofitting the building was examined through nonlinear static and dynamic analyses. By using the nonlinear static analysis, retrofitted buildings seismic performances under lateral seismic load were compared with each other. Moreover, the performance points and response levels of the existing and retrofitting cases were determined by way of the capacity-spectrum method described in ATC-40 (1996). For the nonlinear dynamic analysis the records were selected torepresent wide ranges of duration and frequency content. Considering the change in the stiffness and the energy dissipation capacities, the performance of the existing and retrofitted buildings were evaluated in terms of story drifts and damage states. It was found that each earthquake record exhibited its own peculiarities, dictated by frequency content, duration, sequence of peaks and their amplitude. The seismic performance of retrofitted buildings resulted in lower displacements and higher energy dissipation capacity depending mainly on the properties of the ground motions and the retrofitting strategies. Moreover, severe structural damage (irreparable or collapse) was observed for the existing building. However, buildings with retrofit alternatives exhibited lower damage levels changing from no damage to irreparable damage states.  相似文献   

20.
According to the most modern trend, performance‐based seismic design is aimed at the evaluation of the seismic structural reliability defined as the mean annual frequency (MAF) of exceeding a threshold level of damage, i.e. a limit state. The methodology for the evaluation of the MAF of exceeding a limit state is herein applied with reference to concentrically ‘V’‐braced steel frames designed according to different criteria. In particular, two design approaches are examined. The first approach corresponds to the provisions suggested by Eurocode 8 (prEN 1998—Eurocode 8: design of structures for earthquake resistance. Part 1: general rules, seismic actions and rules for buildings), while the second approach is based on a rigorous application of capacity design criteria aiming at the control of the failure mode (J. Earthquake Eng. 2008; 12 :1246–1266; J. Earthquake Eng. 2008; 12 :728–759). The aim of the presented work is to focus on the seismic reliability obtained through these design methodologies. The probabilistic performance evaluation is based on an appropriate combination of probabilistic seismic hazard analysis, probabilistic seismic demand analysis (PSDA) and probabilistic seismic capacity analysis. Regarding PSDA, nonlinear dynamic analyses have been carried out in order to obtain the parameters describing the probability distribution laws of demand, conditioned to given values of the earthquake intensity measure. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏