首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The physico‐chemical characteristics and microbial composition of the final effluents of two municipal wastewater treatment plants in South Africa were assessed between July and September 2009. The impact of the treated final effluents on the receiving water bodies was also evaluated. The temperature across all sampling points ranged between 14 and 22°C, while pH varied from 6.9 to 7.6. High levels of turbidity, chemical oxygen demand (COD), ammonia, nitrate, nitrite and orthophosphate (PO4) were observed in many cases. Turbidity of the samples was in the range of 2.2–288.6 NTU. The concentrations (mg/L) of other physico‐chemical parameters are as follows: COD (9.33–289); ammonia (0.000340–45.4); nitrate (0.062–539); nitrite (0.021–22.6); PO4 (5.3–33.2). The microbial quality of the effluents discharged from the plants did not comply with the limits set by the South African guidelines with respect to pathogens such as Salmonella, Shigella, Escherichia coli, total coliform, faecal coliform, enterococci, faecal streptococci, and viral particles for effluents intended for discharge into receiving watersheds. This study revealed an undesirable impact on the physico‐chemical and microbial qualities of the receiving water bodies as a result of the discharge of inadequately treated effluents from the wastewater treatment facilities. This poses a health risk to several rural communities which rely on the receiving water bodies primarily as their sources of domestic water and recreational purposes. There is therefore a need for the intervention of appropriate regulatory agencies in South Africa to ensure compliance of treatment facilities with wastewater effluent quality standards.  相似文献   

2.
Improper disposal of wastewater is an important source of groundwater contamination, as it poses serious threats to the environment and human health. In this case study, 18 groundwater and 3 sewage effluent samples were collected from the area adjacent to a wastewater treatment plant in Sohag, Egypt. These samples were subjected to detailed chemical and bacteriological analyses to quantify the potential impact of sewage effluent on the groundwater quality using geochemical indicators. The groundwater aquifer in the study area is represented by the highly permeable Qena Sands that are composed of sands and gravels. The bacteriological analyses indicated the presence of fecal coliform in groundwater at wells nearby the wastewater ponds and farm lands. NH4 concentration of the contaminated groundwater samples ranged from 0.36 to 5.70 mg/L (78% of the samples > 1.20 mg/L) and the NH4 in the non‐impacted samples ranged from 0.40 to 2.23 mg/L (22% > 1.20 mg/L). Variations in NH4 concentrations are due to the transformation processes occurring in the aquifer. The groundwater samples were categorized based on the Na/K ratio into two classes. The first class shows the Na/K ratios vary from 2.52 to 12.19 for sewage effluent and contaminated samples, while in the second class they range from 12.85 to 31.60 for non‐impacted samples. As a result, the Na/K ratio in combination with other chemical and microbiological indicators is a useful screening tool for assessing possible sewage influence on shallow groundwater from shallow wells.  相似文献   

3.
In the present study, the effects of initial COD (chemical oxygen demand), initial pH, Fe2+/H2O2 molar ratio and UV contact time on COD removal from medium density fiberboard (MDF) wastewater using photo‐assisted Fenton oxidation treatment were investigated. In order to optimize the removal efficiency, batch operations were carried out. The influence of the aforementioned parameters on COD removal efficiency was studied using response surface methodology (RSM). The optimal conditions for maximum COD removal efficiency from MDF wastewater under experimental conditions were obtained at initial COD of 4000 mg/L, Fe2+/H2O2 molar ratio of 0.11, initial solution pH of 6.5 and UV contact time of 70 min. The obtained results for maximum COD removal efficiency of 96% revealed that photo‐assisted Fenton oxidation is very effective for treating MDF wastewater.  相似文献   

4.
A dynamic simulation model of the Ankara central wastewater treatment plant (ACWTP) was evaluated for the prediction of effluent COD concentrations. Firstly, a mechanistic model of the municipal wastewater treatment process was developed based on Activated Sludge Model No. 1 (ASM1) by using a GPS‐X computer program. Then, the mechanistic model was combined with a feed‐forward back‐propagation neural network in parallel configuration. The appropriate architecture of the neural network models was determined through several iterative steps of training and testing of the models. Both models were run with the data obtained from the plant operation and laboratory analysis to predict the dynamic behavior of the process. Using these two models, effluent COD concentrations were predicted and the results were compared for the purpose of evaluation of treatment performance. It was observed that the ASM1 ANN model approach gave better results and better described the operational conditions of the plant than ASM1.  相似文献   

5.
The performance of one pilot‐scale and two full‐scale membrane bioreactors (MBR) were evaluated based on the control of main operational parameters, composition of microbial community and pathogens concentration in the treated outlet. Plants were designed for 0.75 m3/day (A), 60 m3/day (B) and 30 m3/day (C). Inlet and outlet samples were monitored for chemical oxygen demand (COD), biological oxygen demand, total suspended solids, ammonia nitrogen concentration (NH4–N), nitrate nitrogen concentration, total Kjeldahl nitrogen, total phosphorus and phosphate phosphorus concentration concentrations. Plants showed good COD removal: 91.9% for Plant A, 97.8% for Plant B and 94.2% for Plant C. The targeted nitrogenous ion was NH4–N due to the requirements for outlet limits. NH4–N removal was moderate for Plant A (73.3%) and Plant B (86.1%) and excellent for Plant C (>99%). Excellent phosphorus removal was achieved by Plant A (average outlet concentration was 0.7 mg/L, efficiency 84.7%). Unsatisfactory results for phosphorus removal were achieved at the full‐scale plants due to operational problems. The dependency between the extracellular polymeric substances increase and decreasing mixed liquor volatile suspended solids for both lab and full‐scale plants was confirmed. Soluble microbial product concentrations were reduced by 65–68% after coagulant dosage for Plant A. Outlets from the MBR plants were monitored for the presence of pathogens (thermotolerant coliforms, Escherichia coli, intestinal Enterococci and culturable microorganisms at 22 and 37°C). The treated effluent from Plant A, B and C met Czech national legislation regarding reuse criteria (standards) for environment, irrigation and swimming purposes. Plants B and C were not able to achieve requirements for potable water and personal hygiene quality standards.  相似文献   

6.
The performance of a constructed wetland for wastewater treatment was examined for four months (December 1995 to March 1996). The study area, hereby referred to as the Splash wetland, is approximately 0·5 ha, and is located in the southern part of Nairobi city. Splash wetland continuously receives domestic sewage from two busy restaurants. Treated wastewater is recycled for re‐use for various purposes in the restaurants. Both wet and dry season data were analysed with a view of determining the impact of seasonal variation on the system performance. The physical and chemical properties of water were measured at a common intake and at series of seven other points established along the wetland gradient and at the outlet where the water is collected and pumped for re‐use at the restaurants. The physico‐chemical characteristics of the wastewater changed significantly as the wastewater flowed through the respective wetland cells. A comparison of wastewater influent versus the effluent from the wetland revealed the system's apparent success in water treatment, especially in pH modification, removal of suspended solids, organic load and nutrients mean influent pH = 5·7 ± 0·5, mean effluent pH 7·7 ± 0·3; mean influent BOD5 = 1603·0 ± 397·6 mg/l, mean effluent BOD5 = 15·1 ± 2·5 mg/l; mean influent COD = 3749·8 ± 206·8 mg/l, mean effluent COD = 95·6 ± 7·2 mg/l; mean influent TSS = 195·4 ± 58·7 mg/l, mean effluent TSS = 4·7 ± 1·9 mg/l. As the wastewater flowed through the wetland system dissolved free and saline ammonia, NH4+, decreased from 14·6 ± 4·1 mg/l to undetectable levels at the outlet. Dissolved oxygen increased progressively through the wetland system. Analysis of the data available did not reveal temporal variation in the system's performance. However, significant spatial variation was evident as the wetland removed most of the common pollutants and considerably improved the quality of the water, making it safe for re‐use at the restaurants. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

7.
In this study, the oxidative decolorization of C.I. reactive yellow 145 (RY 145) from synthetic textile wastewater including RY 145 and polyvinyl alcohol by Fenton and sono‐Fenton processes which are the combination of Fenton process with ultrasound has been carried out. The effects of some operating parameters which are the initial pH of the solution, the initial concentration of Fe2+, H2O2, and the dye, temperature, and agitation speed on the color and chemical oxygen demand (COD) removals have been investigated. The optimum conditions have been found as [Fe2+] = 20 mg/L, [H2O2] = 20 mg/L, pH 3 for Fenton process and [Fe2+] = 20 mg/L, [H2O2] = 15 mg/L, pH 3 for sono‐Fenton process by indirectly sonication at 35 kHz ultrasonic frequency and 80 W ultrasonic power. The color and COD removal efficiencies have been obtained as 91 and 47% by Fenton process, and 95 and 51% by sono‐Fenton processes, respectively. Kinetic studies have been performed for the decolorization of RY 145 under optimum conditions at room temperature. It has been determined that the decolorization has occurred rapidly by sono‐Fenton process, compared to Fenton process.  相似文献   

8.
Olive mills wastewater (OMW) is a critical environmental problem in the Mediterranean area due to its extremely high levels of COD and phenols. In this study, a group of adsorption experiments were conducted to investigate the dynamic response of the pH, COD, phenols, TSS, TDS, and TS concentrations of pretreated OMW, using different concentrations of activated carbon as adsorbent. The pretreatment included sedimentation and filtration of OMW. The pretreated OMW was then subjected to adsorption. A series of adsorption steps in stirred batch vessels were studied, namely, one stage, two‐stage countercurrent, and three‐stage countercurrent adsorption systems. A combined two‐ two‐stage countercurrent adsorption steps were also studied. Experimental results showed that such treatment protocols were promising. For example, a treatment protocol composed of a three‐stage countercurrent adsorption process using activated carbon of concentration of 24 g/L of OMW was able to reduce the COD from 60 000 mg/L down to 22 300 mg/L, while phenols were reduced from 450 to 15 mg/L.  相似文献   

9.
One of the critical technological parameter in operation of aerated submerged fixed‐bed biofilm reactor (ASFBBR) is the control over process of biofilm detachment. Both, an excessive growth of biomass with its accumulation in the bioreactor and an exceeded biofilm detachment rate, cause serious operational and technological problems. The studies presented in this paper demonstrate that in an ASFBBR reactor with a PVC bed carrier media, an effective way to maintain a proper shear stress acting on the biofilm and causing its detachment could be an internal recirculation of wastewater instead of backwashing with wastewater or air flushing. In case of polishing of oil‐refinery wastewater with average COD loading rate equal to 9 g COD/(m2 day), the minimum value of the hydraulic loading rate in such reactor is 1.9 m3/(m2 h), at which there was no excessive growth of biofilms. Despite a significant decrease of the biofilms thickness and amount of biomass in the reactor, there was no significant decline in the efficiency of pollutant removal from oil‐refinery wastewater, which made it possible to obtain the quality of effluent at the outlet of the bioreactor significantly below the water permits and standards.  相似文献   

10.
A start‐up study for biohydrogen production from palm oil mill effluent (POME) is carried out in a pilot‐scale up‐flow anaerobic sludge blanket fixed‐film reactor (UASFF). A substrate with a chemical oxygen demand (COD) of 30 g L?1 is used, starting with molasses solution for 30 days and followed by a 10% v/v increment of POME/molasses ratio. At 100% POME, a hydrogen content of 80%, hydrogen production rate of 36 L H2 per day, and maximum COD removal of 48.7% are achieved. Bio‐kinetic coefficients of Monod, first‐order, Grau second‐order, and Stover‐Kincannon kinetic models are calculated to describe the performance of the system. The steady‐state data with 100% POME shows that Monod and Stover‐Kincannon models with bio‐kinetic coefficients of half‐velocity constant (Ks) of 6000 mg COD L?1, microbial decay rate (Kd) of 0.0015 per day, growth yield constant (Y) of 0.786 mg volatile suspended solids (VSS)/mg COD, specific biomass growth rate (μmax) of 0.568 per day, and substrate consumption rate of (Umax) 3.98 g/L day could be considered as superior models with correlation coefficients (R2) of 0.918 and 0.989, respectively, compared to first‐order and Grau's second‐order models with coefficients of K1 1.08 per day, R2 0.739, and K2s 1.69 per day, a = 7.0 per day, b = 0.847.  相似文献   

11.
This study attempts to explore the possibility of treating dye solutions containing Disperse Yellow 119 and Disperse Red 167 by Fenton and Fenton under solar‐light oxidation processes. Experiments were conducted to examine the effects of various operating conditions on the performance of the treatment systems. The Fenton results showed that 98.6% spectral absorption coefficient (SAC) and 90.8% chemical oxygen demand (COD) removals were proved at pH 3, 50 mg/L Fe2+, and 75 mg/L H2O2, 15 min oxidation time for Disperse Yellow 119. After 40 min solar irradiation time during Fenton process the SAC removal was 99.1%. COD reduction of about 98.3% was observed at the same time. It was also obtained as 97.8% SAC and 97.7% COD removal with pH 3, 75 mg/L Fe2+, 100 mg/L H2O2, and 25 min oxidation time for Disperse Red 167 at this optimum conditions. For Disperse Red 167 during Fenton under solar light process, after 40 min of solar irradiation time the SAC and COD reduction were obtained 99.3 and 98.4%, respectively.  相似文献   

12.
ABSTRACT

Anthropic pressures deteriorate river water quality, so authorities need to identify their causes and define corrective actions. Physically based water quality models are a useful tool for addressing physicochemical pollutants, but they must be calibrated with an amount of data that is often unavailable. In this study, we explore the characterization of a model to design corrective interventions in a context of sparse data. A calibration indicator that is both simple and flexible is proposed. This approach is applied to the Middle Tagus Basin in central Spain, where the physicochemical concentration of pollutants is above legal standards. We quantify the effects of the main existing pressures (discharge from wastewater treatment plants, agricultural diffuse pollution and a major inter-basin water transfer) on the receiving waters. In particular, the study finds that wastewater treatment plant effluent concentrations should be reduced to up to 0.65 mg/L of ammonium and 0.55 mg/L of phosphate to achieve the environmental goals. We propose and prioritize a set of policy actions that would contribute to the good status of surface water bodies in the region.  相似文献   

13.
The main purpose of this study was to examine the hydrogeochemical factors leading to nitrate contamination of shallow groundwater in an agricultural area. Another purpose was to identify relationships between variations in organic matter levels (as estimated by the BOD and COD parameters) of groundwater that transports effluent from small‐scale livestock holdings. Major cations, anions, BOD and COD of organic matter and total coliforms were analysed. It was found that groundwaters beneath cultivated areas and areas carrying livestock had higher concentrations of calcium, nitrate and chloride than did freshwater. Above all, the nitrification process increased concentrations of nitrate. Nitrate levels were depressed in some places where the groundwater was low in dissolved oxygen. Groundwaters affected by livestock activities showed high concentrations of organic matter (BOD, COD) and high microbial concentrations (as indicated by total coliforms). The COD/BOD ratio increased in the downward direction. It was inferred that this was due to the faster loss of easily biodegradable organic matter compared with non‐biodegradable organic matter proceeding away from a discharge. Accordingly, it is possible to trace effluent in a small area back to a point source by monitoring the COD/BOD ratio of groundwater. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

14.
Sulfate‐reduction data from various anaerobic reactor configurations, e. g., upflow anaerobic sludge blanket reactor (UASBR), completely stirred tank reactor (CSTR), and batch reactor (BR) with synthetic wastewaters, having glucose and acetate as the substrates and different levels of sulfate, were evaluated to determine the level of sulfate‐reducing activity by sulfate‐reducing bacteria coupled to organic matter removal. Anaerobic reactors were observed for the degree of competition between sulfate‐reducing sulfidogens and methane producing bacteria during the degradation of glucose and acetate. Low sulfate‐reducing activity was obtained with a maximum of 20% of organic matter degradation with glucose‐fed upflow anaerobic sludge bed reactors (UASBRs), while a minimum of 2% was observed with acetate‐fed batch reactors. The highest sulfate removal performance (72–89%) was obtained from glucose fed‐UASB reactors, with the best results observed with increasing COD/SO4 ratios. UASB reactors produced the highest level of sulfidogenic activity, with the highest sulfate removal and without a performance loss. Hence, this was shown to be the optimum reactor configuration. Dissolved sulfide produced as a result of sulfate reduction reached 325 mg/L and 390 mg/L in CST and UASB reactors, respectively, and these levels were tolerated. The sulfate removal rate was higher at lower COD/SO4 ratios, but the degree of sulfate removal improved with increasing COD/SO4 ratios.  相似文献   

15.
A solid‐phase extraction (SPE)‐gas chromatography (GC)‐mass spectrometry (MS) analytical method was developed for the simultaneous analysis of natural free estrogens and their conjugates in wastewater samples. Natural free estrogens and their conjugates in wastewater were successfully separated by the oasis hydrophilic‐lipophilic balance solid phase extraction (Oasis HLB SPE) method, and the conjugates were initially enzyme hydrolyzed by β‐glucuronidase or arylsulfatase from Helix pomatia prior to derivatization. N‐methyl‐N‐(tert‐butyldimethylsilyl)trifluoroacetamide (MTBSTFA) plus 1% tert‐butyldimetheylchlorosilane (TBDMCS) was chosen as the derivatization reagent, and the most appropriate conditions of derivatization were determined to be at 95°C for 90 min. The recovery ratios of nine target chemicals were determined by spiking them in 1 L of ultra‐purified water or the influent of a wastewater treatment plant (WWTP). The recovery ratios of six out of nine for the analytes ranged from 73.3–114.9% with relative standard deviations (RSD) from 1.6–19.9%. The established method was successfully applied to environmental wastewater samples which were collected from one municipal wastewater treatment plant (WWTP) in Osaka, Japan, for the determination of natural free estrogens and their conjugates. In the influent sample, E1, E2, E1‐3S, E3‐3S, and E1‐3G were detected at concentrations of 16.6, 9.6, 8.2, 21.9, and 3.2 ng L–1, respectively. However, only E1 was detected at a high concentration of 44 ng L–1 in the effluent sample, suggesting that it is the dominant natural free estrogen in the effluent.  相似文献   

16.
The present work investigated the biosorption of nickel from synthetic and electroplating industrial effluents using a green marine algae Ulva reticulata. Preliminary batch results imply that pH 4.5 was optimum for nickel uptake and the isotherm experiments conducted at this pH condition indicated that U. reticulata can biosorb 62.3 mg g–1 nickel ions from synthetic solutions, according to the Langmuir model. Desorption was effective and practical using 0.1 M CaCl2 (pH 2.5, HCl) and the biomass was regenerated and reused for three cycles. Continuous biosorption experiments were performed in an upflow packed column (2 cm I.D and 35 cm height). Among the two electroplating effluents used, effluent‐1 is characterized by excess co‐ions and high nickel ion content. This influenced the column nickel uptake with U. reticulata exhibiting 52.1 mg g–1 in the case of effluent‐1 compared to 56.5 mg g–1 in the case of synthetic solution. On the other hand U. reticulata performed well in effluent‐2 with uptakes of 53.3 and 54.3 mg g–1 for effluent‐2 and synthetic solution, respectively. Mathematical modeling of column experimental data was performed using nonlinear forms of the Thomas‐ and modified dose‐response models, with the latter able to simulate breakthrough curves with high correlation coefficients.  相似文献   

17.
The aim of this study is to evaluate the feasibility of sludge digester effluent as feeding solution to enrich anaerobic ammonium oxidation (anammox) bacteria. The performance of the two parallel pilot scale‐upflow packed bed anammox reactors (UPBAn1 and UPBAn2) are examined in terms of the enrichment of anammox bacteria. The control experiment is set up conducting synthetic wastewater as feeding solution in the UPBAn1 reactor whereas, the sludge digester effluent is fed to the nitritation reactor and then the partially nitrated digester effluent to the UPBAn2 reactor. Anammox activities are evaluated by mass balances based on ammonium (NH4+), nitrite (NO2?), and nitrate (NO3?) analysis and NRR. Microbial community of anammox bacteria is analyzed using real‐time polymerase chain reaction (PCR). The results demonstrate that UPBAn 1 and UPBAn2 reactors are successfully enriched on days 64 and 40 with NRRs of 19.54 and 19.43 g N m?3 per day, respectively. This study reveals that both synthetic wastewater and digester effluent are suitable for the enrichment of anammox bacteria; however, digester effluent as feeding solution for enrichment of anammox bacteria based on the ease of process control and process stability is more advisable.  相似文献   

18.
Oil refinery wastewater was treated using a coupled treatment process including electrocoagulation (EC) and a fixed film aerobic bioreactor. Different variables were tested to identify the best conditions using this procedure. After EC, the effluent was treated in an aerobic biofilter. EC was capable to remove over 88% of the overall chemical oxygen demand (COD) in the wastewater under the best working conditions (6.5 V, 0.1 M NaCl, 4 electrodes without initial pH adjustment) with total petroleum hydrocarbon (TPH) removal slightly higher than 80%. Aluminum release from the electrodes to the wastewater was found an important factor for the EC efficiency and closely related with several operational factors. Application of EC allowed to increase the biodegradability of the sample from 0.015, rated as non-biodegradable, up to 0.5 widely considered as biodegradable. The effluent was further treated using an aerobic biofilter inoculated with a bacterial consortium including gram positive and gram negative strains and tested for COD and TPH removal from the EC treated effluent during 30 days. Cell count showed the typical bacteria growth starting at day three and increasing up to a maximum after eight days. After day eight, cell growth showed a plateau which agreed with the highest decrease on contaminant concentration. Final TPHs concentration was found about 600 mgL−1 after 30 days whereas COD concentration after biological treatment was as low as 933 mgL−1. The coupled EC-aerobic biofilter was capable to remove up to 98% of the total TPH amount and over 95% of the COD load in the oil refinery wastewater.  相似文献   

19.
The primary degradation of a technical nonylphenol ethoxylate surfactant with an average chain length of 10 ethoxylate units (NPEO‐10) was studied in a flow‐through system by means of miniaturized biofilm reactors (mBFR) with bacteria from an activated sludge plant. 5 mg/L of the test compound (total EO concentration) were spiked in synthetic wastewater (SWW) and fed to the reactors continuously for 64 days. Compound removal and the formation of degradation products (DP) were monitored under both oxic and anoxic conditions. Solid‐phase extraction and RP‐HPLC with fluorescence detection were employed for sample preparation and analysis. Better removal of the parent compound was seen with the oxic reactors (50 to 70%) than with the anoxic reactors (30 to 50%). Compared to SWW organic matter, the test compound proved to be of refractory nature. The appearance of degradation products in the effluent was earlier with anoxic reactors despite their lower elimination efficiency. After extraction of biomass only minor amounts of NPEO‐10 and metabolites were found, indicating that small amounts were present in adsorbed or intracellular form. Ultimate biodegradation of NPEO‐10 and of octylphenol ethoxylates (OPEO‐9.5; average chain length of 9.5 EO units) was tested by means of manometric respirometry at a theoretical oxygen demand (ThOD) of 100 mg/L. Whereas NPEO‐10 was biodegraded by only 26%, at best, in 28 days, OPEO‐9.5 degradation amounted to (40 ± 5)%.  相似文献   

20.
Major challenges attributed to dysfunctional wastewater treatment facilities in developing countries include lack of commitment and poor informed decision making by the higher municipal administration. This paper presents how process monitoring and control during full scale operation ensures sustainability of civic infrastructures like Al‐Bireh wastewater treatment plant (AWWTP). It is written from the perspective of practical process selection to evaluate the performance of AWWTP, a single‐sludge nitrification–denitrification process with aerobic sludge stabilization. Process monitoring data (July 2000–April 2007) from available monthly operating reports were analyzed and evaluated. Additional data on microbiological analysis and information about facility unit operations were gathered through review of published local literature and interviews with AWWTP personnel. Influent and effluent data evaluated were the chemical oxygen demand (COD), biological oxygen demand (BOD), total nitrogen (TN), and total phosphorus (TP). Despite annual and seasonal variations in AWWTP influent for COD, BOD, TN, and TP, the Palestinian wastewater reuse requirements for restricted irrigation were met. Process design and proper facility operation have direct impacts on effluent quality. The study concludes that regardless of the design capacity and process type, adequate administrative and operational management dictate the sustainability of AWWTP and reuse schemes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号