首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The present work focuses on the performance of Fenton, sono‐Fenton, and sono‐photo‐Fenton processes for the oxidation of phenol present in aqueous solution. The effects of H2O2 concentration, Fe2+ concentration, pH, and initial phenol concentration on the oxidation of phenol were studied. The optimum Fe2+ and H2O2 concentrations for the Fenton process were 45 and 800 mg/L, respectively. For the sono‐Fenton process, the optimum Fe2+ and H2O2 concentrations were 30 and 800 mg/L, respectively. The optimal conditions for the sono‐photo‐Fenton process were found to be 20 mg/L of Fe2+ and 700 mg/L of H2O2. The optimum pH was found to be 3 for the processes investigated in the present study. The analysis of results showed that the sono‐photo‐Fenton method reduced the Fe2+ concentration by 30–50% and the H2O2 concentration by 12.5%. It was found that the sono‐photo‐Fenton technique showed better performance than the Fenton and sono‐Fenton processes for the oxidation of phenol. A lumped kinetic model was used to predict the chemical oxygen demand reduction and the model was found to fit the data.  相似文献   

2.
The present work demonstrates the applicability of ferrites as photo‐Fenton catalysts for deterioration of different phenolic derivatives. To analyze optimal reaction conditions, experiments are performed with four magnetic spinel ferrites MFe2O4 (M = Co, Cu, Ni, and Zn) and two inorganic oxidants, i.e., hydrogen peroxide (HP) and potassium peroxymonosulfate (PMS). The reactions are performed using p‐nitrophenol as phenolic probe. CuFe2O4 and CoFe2O4 possessed excellent ability to activate HP and PMS, respectively, among all four synthesized catalysts. A noteworthy aspect of two oxidizing agents is that the concentration of PMS used during the reaction is four times less than HP. Further, the broad pH activity of PMS provides a significant advantage over HP. The optimal reaction conditions, when HP is the oxidant in the photo‐Fenton degradation, are 0.50 g L?1 MFe2O4, pH 2.5, and 8.8 mM HP. Although PMS is active in a wide pH range (2–10), adequate reaction conditions are 0.50 g L?1 MFe2O4, natural pH, and 2.2 mM PMS. The photo‐Fenton activity of ferrites is extended to the degradation of different nitro‐ and chloro‐analogs of phenol (2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2,4‐dinitrophenol, 2,4,6‐trinitrophenol, 2‐chlorophenol, 3‐chlorophenol, 4‐chlorophenol, 2,4‐dichlorophenol) with only two ferrites (CuFe2O4 and CoFe2O4). A comparative study is performed with the two oxidants (HP and PMS) with positive results. Finally, stability and reusability of magnetic ferrites as catalysts are also studied to prove their use in phenolic solution treatment.  相似文献   

3.
The degradation reactions of two monoazo pigments, namely, Red 53:1 and Red 48:2, by Fenton, photo‐Fenton and UV/H2O2 systems have been studied. The efficiencies of the Fenton reactions increased with temperature, but the formation of solid agglomerates was observed when the reactions were carried out above 50°C indicating a coagulant action of Fe+2 or Fe+3. Photo‐Fenton reactions irradiated by sunlight presented the best rate constants for cleavage of the azo bond and the naphthalene rings. The UV/H2O2 system exhibited the highest efficiency with respect to the consumption of H2O2. The presence of a carbonyl group in the ortho position of the naphthol ring hampered the oxidation of pigment Red 48:2 by hydroxyl radicals. This finding may be explained in terms of the acceptor character of the COOH group, and suggests the formation of a complex containing two six‐membered rings between Fe+3 and the pigment molecule.  相似文献   

4.
This experimental research deals with using steel scrap as a heterogeneous catalyst. This catalyzes the oxidation reaction of real textile dye wastewater based on a modified solar photo‐Fenton oxidation process. Morphologic analysis and mapping of the elementary composition of the steel scrap have been carried out by scanning electron microscopy. The effects of concentration of H2O2, the pH of the solution and the catalyst loading on the degradation of textile dye wastewater are elucidated. Kinetic studies have been performed for the decolorization of wastewater under optimum conditions. It could be concluded that the steel scrap is a potential substitute for ferrous salts as a catalyst for the solar photo‐Fenton reaction.  相似文献   

5.
Design of Fenton and photo‐Fenton reactions was partially automated by using sequential injection analysis (SIA) and response surface methodology for the treatment of a wastewater sample from a coatings industry. The extension of both Fenton and photo‐Fenton reactions was evaluated by the percentage of total organic carbon (TOC) remaining in solution after 15 min of reaction. Use of small volumes of sample and reagents, as well as easy solution handling, were the remarkable features of the proposed system. The highest percentage of TOC removal (79%) was obtained by the photo‐Fenton reaction at the following initial mass‐based concentration ratios: H2O2/TOC = 10, H2O2/FeSO4 = 50, and pH 2.5. The best result for Fenton reaction indicated a TOC removal of only 45%, obtained at H2O2/initial TOC = 20, H2O2/FeSO4 = 30, and pH 2.5. The SIA system was designed to dispense reagents to the sample flasks and to drive the sample intended to photo‐Fenton reaction through a homemade photo‐reactor. Modifications in chemical parameters of the reactions were achieved via the software commanding the SI system, without the need for physical reconfiguration of reagents around the selection valve.  相似文献   

6.
In the present study, the effects of initial COD (chemical oxygen demand), initial pH, Fe2+/H2O2 molar ratio and UV contact time on COD removal from medium density fiberboard (MDF) wastewater using photo‐assisted Fenton oxidation treatment were investigated. In order to optimize the removal efficiency, batch operations were carried out. The influence of the aforementioned parameters on COD removal efficiency was studied using response surface methodology (RSM). The optimal conditions for maximum COD removal efficiency from MDF wastewater under experimental conditions were obtained at initial COD of 4000 mg/L, Fe2+/H2O2 molar ratio of 0.11, initial solution pH of 6.5 and UV contact time of 70 min. The obtained results for maximum COD removal efficiency of 96% revealed that photo‐assisted Fenton oxidation is very effective for treating MDF wastewater.  相似文献   

7.
The present study employed a modified Fenton system that aims to extend the optimum pH range towards neutral conditions for studying the oxidation of benzene, toluene, ethyl benzene, xylenes (BTEX) using glutamic acid (Glu) as an iron chelator. Addition of 20 mM Glu greatly enhanced the oxidation rate of BTEX in modified Fenton system at pH 5–7. A rapid mass destruction (>97% after 1 h) of BTEX as a water contaminant carried out in the presence of 500 mM H2O2, 10 mM Fe2+, and 20 mM Glu at pH 5 could be shown. The efficiency of this modified Fenton's system for mass destruction of BTEX in contaminated water was measured to estimate the impact of the major process variables that include initial concentrations of soluble Fe, H2O2, Glu (as metal chelating agent), and reaction time.  相似文献   

8.
In this study, the oxidative decolorization of C.I. reactive yellow 145 (RY 145) from synthetic textile wastewater including RY 145 and polyvinyl alcohol by Fenton and sono‐Fenton processes which are the combination of Fenton process with ultrasound has been carried out. The effects of some operating parameters which are the initial pH of the solution, the initial concentration of Fe2+, H2O2, and the dye, temperature, and agitation speed on the color and chemical oxygen demand (COD) removals have been investigated. The optimum conditions have been found as [Fe2+] = 20 mg/L, [H2O2] = 20 mg/L, pH 3 for Fenton process and [Fe2+] = 20 mg/L, [H2O2] = 15 mg/L, pH 3 for sono‐Fenton process by indirectly sonication at 35 kHz ultrasonic frequency and 80 W ultrasonic power. The color and COD removal efficiencies have been obtained as 91 and 47% by Fenton process, and 95 and 51% by sono‐Fenton processes, respectively. Kinetic studies have been performed for the decolorization of RY 145 under optimum conditions at room temperature. It has been determined that the decolorization has occurred rapidly by sono‐Fenton process, compared to Fenton process.  相似文献   

9.
This study attempts to explore the possibility of treating dye solutions containing Disperse Yellow 119 and Disperse Red 167 by Fenton and Fenton under solar‐light oxidation processes. Experiments were conducted to examine the effects of various operating conditions on the performance of the treatment systems. The Fenton results showed that 98.6% spectral absorption coefficient (SAC) and 90.8% chemical oxygen demand (COD) removals were proved at pH 3, 50 mg/L Fe2+, and 75 mg/L H2O2, 15 min oxidation time for Disperse Yellow 119. After 40 min solar irradiation time during Fenton process the SAC removal was 99.1%. COD reduction of about 98.3% was observed at the same time. It was also obtained as 97.8% SAC and 97.7% COD removal with pH 3, 75 mg/L Fe2+, 100 mg/L H2O2, and 25 min oxidation time for Disperse Red 167 at this optimum conditions. For Disperse Red 167 during Fenton under solar light process, after 40 min of solar irradiation time the SAC and COD reduction were obtained 99.3 and 98.4%, respectively.  相似文献   

10.
A simple, low cost, highly effective, and useful Fenton oxidation treatment of synthetic dye bath waste with pickling liquor as a source of iron (Fe2+ catalyst) is reported. Optimizations of contact time, Fe2+ and H2O2 doses are carried out. Oxidative de‐colorization and degradation of Reactive Blue 4 and Reactive Orange 16 was measured in terms of decrease in absorbance at their wavelength of maximum absorption (RB4, 599 nm; and RO16, 493 nm) and also as reduction in chemical oxygen demand (COD). Approximately, 62% COD was removed in 2 h at optimized doses of Fe2+ (8.95 mM) and H2O2 (61.8 mM) by using pickling waste as a source of Fe2+ catalyst. Similar performance efficiency was observed when neat FeSO4 was used as a source of Fe2+, indicating that pickling liquor can be a low cost source of Fe2+ to treat synthetic dye bath waste by Fenton method.  相似文献   

11.
In this study, the decolorization, dearomatization, and mineralization efficiencies of different advanced oxidation processes (AOPs; namely O3, O3/Fe(II), O3/Fe(II)/UVA, and O3/TiO2/UVA) were investigated for the azo dye C.I. Reactive Red 194 (RR194). The effects of pH (3–11), amount of TiO2 (0.05–1 g/L), and concentration of Fe(II) (0.1–1.6 mM) were investigated for the applied methods. The decolorization and mineralization efficiencies of the photocatalytic ozonation system (O3/TiO2/UVA) were increased by decreasing the pH of the dye solution in contrast to the ozonation system (O3). Decolorization of RR194 was increased in the photocatalytic ozonation system with an increasing amount of catalyst however, a decreasing was occurred for the homogeneous catalytic system (O3/Fe(II)) when increasing the concentration of catalyst. The decolorization efficiency of the homogeneous catalytic system (O3/Fe(II)) was enhanced when combined with UVA light. In our study, the most efficient method for dearomatization and mineralization was the O3/TiO2/UVA among the applied AOPs.  相似文献   

12.
In this work, the treatment of photographic processing wastewaters (PPW) by electro‐Fenton process has been investigated. The Influence of operating conditions on kinetics and efficiency of electro‐Fenton process has been evaluated using carbon felt cathode and platinium (Pt) or boron‐doped diamond (BDD) anode. The results of electro‐Fenton treatment of PPW have shown that nearly complete removal of total phenols was obtained for all combinations with pseudo‐first rate constants of 0.07, 0.012, and 0.018/min for carbon felt/Pt, carbon felt/BDD and Pt/BDD cathode/anode combinations, respectively. The combination of carbon felt cathode with BDD anode achieved the highest total organic carbon (TOC) removal of 90%, while it did not exeed 40% for carbon felt/Pt combination. Increasing current intensity and Fe2+ dose enhances the efficiency of electro‐Fenton process. However, increasing pH decreases TOC removal during the treatment of PPW by electro‐Fenton process. The highest efficiency of electro‐Fenton process using BDD anode can be explained by the contribution of direct and indirect oxidation routes in the degradation mechanism of organics including (i) oxidation via hydroxyl radicals generated from the catalytic decomposition of H2O2 and from water discharge on BDD anode, (ii) direct oxidation of certain organic compounds on BDD anode, and (iii) mediated oxidation with inorganic oxidants electrogenerated from anodic oxidation of supporting salts.  相似文献   

13.
Fenton process was investigated for the purpose of biological sludge disintegration. The Box–Wilson experimental design was employed to evaluate the effects of major process variables (Fe(II) and H2O2 concentrations) on both disintegration and dewatering performance of sludge. Results showed that 4 g Fe(II)/kg total solids (TSs) and 60 g H2O2/kg TS are efficient for floc disintegration. Fenton pre‐treatment enhanced the biodegradability of sludge. For 4 g Fe(II)/kg TS and 60 g H2O2/kg TS, 19.4% higher methane production was achieved compared to raw sludge in biochemical methane potential assay. Fenton pre‐treatment resulted in the release of organic sludge components into the liquid phase. For 4 g Fe(II)/kg TS and 60 g H2O2/kg TS, dissolved organic carbon and total nitrogen in sludge's supernatant increased by 75.74 and 60.60%, respectively. Fenton pre‐treatment enhanced the filterability of sludge and it can be applied for conditioning purpose before mechanical dewatering units.  相似文献   

14.
The feasibility of pilot‐scale mineralization of organic pollutants in wastewaters using the Electro‐Fenton® process is demonstrated. The treatment was applied in a continuous‐flow reactor, to solutions of nitrobenzene, 2,4‐D and benzoic acid and to actual wastewaters from a fine chemicals company along with a pulp and paper company. The results showed mineralization yields from 60 to 84% by simply applying the Electro‐Fenton® process. When a subsequent exposure to sunlight was carried out (Helielectro‐Fenton method), this mineralization almost went to completion, except for the effluent from the fine chemicals industry.  相似文献   

15.
The removal of chemical oxygen demand (COD) and phenol from olive oil mill wastewaters (OOMW) was investigated experimentally by using conventional Fenton (CFP) and Fenton type processes (FTP) with zero valent iron (ZVI). Different operational parameters such as initial pH, Fe2+, Fe0, and H2O2 concentrations were examined. Kinetic studies in terms of COD and phenol removals for both CFP and FTP were performed. The original pH value (4.6) of OOMW for CFP was found as the optimum pH. The determined optimum conditions are [Fe2+] = 1500 mg L?1, [H2O2] = 1750 mg L?1, and pH = 4.6 for CFP; [Fe0] = 2000 mg L?1, [H2O2] = 2000 mg L?1, and pH = 3 for FTP. 82.4% COD and 62% phenol removals were performed under the optimum conditions by CFP, while 82% COD and 63.4% phenol were removed by FTP. According to the results of kinetic studies, it was observed that COD and phenol were removed by FTP more rapidly, compared to CFP. Consequently, it was determined that both CFP and FTP were effective processes for the pretreatment of OOMW.  相似文献   

16.
The amination water (AW) effluent stream from the industrial production of the trifluraline herbicide was submitted to an oxidation‐coagulation treatment with potassium ferrate, combined with advanced oxidation processes. The experimental results obtained by analysis of variance (ANOVA) for the oxidation‐coagulation‐Fenton process, evaluating the variables pH (A), Fe(VI) concentration (B), and H2O2 concentration (C), demonstrated that the regression equation resulting from the Response Surface Methodology (RSM) experimental design, for the quadratic model, was ηAbs (%) = 36.9– 21.58A + 8.37A2 + 1.36B + 0.92B2 + 1.08C + 1.52C2 + 1.27AB – 1.34AC + 1.33BC. The maximum absorptiometric color reduction occurred at pH 3, with corresponding maximum amounts of iron and hydrogen peroxide. The absorptiometric color and COD reduction were 96% and 57%, respectively. For the oxidation‐coagulation‐photo‐Fenton process, the analyzed variables were pH (A), Fe(VI) concentration (B), H2O2 concentration (C), and temperature (D). The regression equation resulting from the quadratic model was ηAbs (%) = 38.3 – 20.2A + 8.12A2 – 0.27B + 3.73B2 + 0.3C + 3.6C2 + 1.67D + 3.1D2 + 1.72AB + 0.51AC – 1.82AD + 0.74BC – 1.11BD + 0.03CD. The ANOVA response showed that the highest absorptiometric color reduction occurred at pH 3, with respective maximum amounts of iron and hydrogen peroxide at 60°C. The maximum efficiencies achieved by the proposed treatment process for the trifluraline effluent stream were 95% and 85%, for absorptiometric color and COD reduction, respectively.  相似文献   

17.
Decolorization of C.I. Basic Blue 3 (BB3) by oxalate catalyzed photoelectro‐Fenton process based on carbon nanotube‐polytetrafluoroethylene (CNT‐PTFE) electrode as cathode under visible light was studied. A comparison of electro‐Fenton, photoelectro‐Fenton, and photoelectro‐Fenton/oxalate processes for decolorization of the solution containing BB3 has been performed. The results showed that color removal follows the decreasing order: photoelectro‐Fenton/oxalate > photoelectro‐Fenton > electro‐Fenton. Response surface methodology (RSM) was employed to assess individual and interactive effects of the four main independent parameters on the decolorization efficiency. A central composite design (CCD) was employed for optimization of photoelectro‐Fenton/oxalate treatment of BB3. The analysis of variance (ANOVA) showed a high coefficient of determination value (R2 = 0.958) and satisfactory prediction second‐order regression. This study clearly showed that RSM was one of the suitable methods to optimize the operating conditions.  相似文献   

18.
This study illustrates the degradation of an azo dye, Reactive Yellow 81 (RY81), by the combined irradiation of UV‐C and ultrasound in the presence of homogeneous (Fe2+) and heterogeneous (TiO2, ZnO) catalysts. The efficiency of homogeneous and heterogeneous oxidation systems was evaluated in regard of the decolorization and mineralization of RY81. Decolorization followed pseudo‐first‐order kinetics with homogeneous and heterogeneous catalysts. Complete color removal was accomplished by homogeneous sonocatalytic and sonophotocatalytic oxidation processes with apparent rate constants of 0.96 × 10?3 and 46.77 × 10?3 s?1, respectively, in the presence of Fe2+. However, partial color removal was obtained by heterogeneous sonocatalytic, photocatalytic, and sonophotocatalytic oxidation processes with apparent rate constants of 2.32 × 10?3, 3.60 × 10?3, and 3.67 × 10?3 s?1, respectively, in the presence of ZnO. TiO2 had the worst catalytic effect of all of the oxidation processes. The addition of hydrogen peroxide increased the rate constants of the heterogeneous oxidation processes and decreased the rate constants of the homogeneous oxidation processes. RY81 mineralization was 62.8% for the US/UV/Fe2+ homogeneous oxidation process, which was the best oxidation process, whereas it was 43.5% for the US/UV/ZnO/H2O2 heterogeneous oxidation process within 2 h reaction time.  相似文献   

19.
Feasibility of photocatalytic dechlorination of PCB‐138 and Aroclor‐1254 using platinum loaded TiO2 (P25) in an alkaline 2‐propanol medium has been investigated. Experiments were conducted in batch mode using a Rayonet photo‐reactor under aerated and deaerated conditions with black lamps emitting around 350 nm as light source. Two forms of platinum deposition were investigated: Photochemically loaded P25 as well as addition of potassium hexachloroplatinate into the reaction medium. Partial dechlorination of PCBs was observed after 7 h of irradiation with pure TiO2 as catalyst when the reaction vessel was kept open to air. Complete dechlorination was observed after 5 h of irradiation in a deaerated environment. Enhanced photocatalytic efficiency was observed when platinum deposited P25 was used as catalyst, with the best result being obtained when aqueous potassium hexachloroplatinate was added into the reaction medium. Lower potassium hexachloroplatinate concentration (0.1 mM) yielded better performance.  相似文献   

20.
沉积物中有机质的削减是黑臭水体治理的关键.Fenton(Fe^2++H2O2)试剂在有机污染废水和土壤原位修复中的应用广泛且效果良好;Fenton试剂也能很好地去除黑臭水体中的色度和浊度,但其氧化沉积物有机质的研究未见报道.为探究Fenton试剂对黑臭水体沉积物的氧化效果,本研究通过室内模拟实验用Fenton氧化法对黑臭河道沉积物进行处理,考察氧化过程沉积物特征和性质的变化;分析覆水后沉积物中污染物的释放特征,并和H2O2体系(无Fe^2+)进行比较.结果表明:Fenton体系显著提高了沉积物与上覆水的氧化还原电位,对黑臭河道沉积物中的有机质具有很强的氧化效率.在温度为28℃、H2O2为20%Q(Q为体系中沉积物有机质完全矿化的理论H2O2用量)和Fe^2+∶H2O2(摩尔比)为0.5∶1时,反应1 d,酸挥发性硫化物去除率为70.13%,沉积物总有机碳减少了22.14%,总有机氮减少了87.60%,生成了较多的铵态氮和硝态氮;由于铁对磷的钝化,沉积物中溶解性反应磷含量大幅减少.H2O2体系的氧化速度较Fenton体系慢,覆水后对体系中的Eh提高不明显.值得注意的是,Fenton体系会降低上覆水的pH,释放较多的铵态氮.需要联合其他技术(如微生物法),强化水体中有机质和氨氮的降解,以取得理想的修复作用.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号