首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The linear response of an idealized concrete gravity dam monolith to harmonic horizontal or vertical ground motion is presented for a range of the important system parameters that characterize the properties of the dam, foundation rock, impounded water and reservoir bottom materials. Based on these frequency response functions, the effects of alluvium and sediments at the reservoir bottom on the response of the dam, including its interaction with the impounded water and foundation rock, are investigated. It is shown that the partial absorption of hydrodynamic pressure waves by the reservoir bottom materials has an important effect on the dynamic response of concrete gravity dams.  相似文献   

2.
The linear response of a selected arch dam to harmonic upstream, cross-stream or vertical ground motion is presented for a wide range of the important system parameters characterizing the properties of the dam, impounded water, reservoir boundary materials and foundation rock. Based on these frequency response functions, the hydrodynamic and foundation flexibility effects in the dynamic response of arch dams are investigated.  相似文献   

3.
A procedure is presented to analyse the response of concrete gravity dams due to horizontal and vertical earthquake ground motion components considering dam-water interaction and partial absorption of hydrodynamic pressure waves at the reservoir bottom into the foundation medium. The effects of reservoir bottom absorption on the hydrodynamic force on a rigid dam are examined first. The harmonic response of an idealized dam cross-section is presented for a wide range of parameters characterizing the properties of the dam, the impounded water and the foundation medium. Based on these frequency response functions the effects of dam-water interaction and of reservoir bottom absorption in the response of dams due to horizontal and vertical components of ground motion are investigated.  相似文献   

4.
The seismic performance of underground reservoir structures depends on the properties of the structure, soil, and ground motion as well as the kinematic constraints imposed on the structure. A series of four centrifuge experiments were performed to evaluate the influence of site response, structural stiffness, base fixity, and excitation frequency on the performance of relatively stiff reservoir structures buried in dry, medium-dense sand. The magnitude of seismic thrust increased and the distribution of seismic earth pressures changed from approximately triangular to parabolic with increasing structural stiffness. Heavier and stiffer structures also experienced increased rocking and reduced flexural deflection. Fixing the base of the structure amplified the magnitude of acceleration, seismic earth pressure, and bending strain compared to tests where the structure was free to translate laterally, settle, or rotate atop a soil layer. The frequency content of transient tilt, acceleration, dynamic thrust, and bending strain measured on the structure was strongly influenced by that of the base motion and site response, but was unaffected by the fundamental frequency of the buried structure (fstructure). None of the available simplified procedures could capture the distribution and magnitude of seismic earth pressures experienced by this class of underground structures. The insight from this experimental study is aimed to help validate analytical and numerical methods used in the seismic design of reservoir structures.  相似文献   

5.
Hydrodynamic pressures and structural response of concrete gravity dams, including dam-reservoir interaction, due to the vertical component of earthquake ground motions are investigated. The response of the dam is approximated by the deformations in the fundamental mode of vibration, and the effects of deformability of bed rock on hydrodynamic pressures are recognized in the analysis. Expressions for the complex frequency response functions for the dam displacement, dam acceleration and lateral hydrodynamic force are derived. These results along with the Fast Fourier Transform algorithm are utilized to compute the time-history of responses of dams of 100, 300 and 600 ft height, with full reservoir, for different values of elastic modulus of mass concrete: 3.0, 3.5, 4.0, 4.5 and 5.0 million psi, to the vertical component of El Centro, 1940, and Taft, 1952, ground motions. It is concluded that the hydrodynamic forces caused by vertical ground motion are affected substantially by damreservoir interaction and depend strongly on the modulus of elasticity of the dam. The dam response to the vertical component of ground motion is compared with that due to the horizontal component. It is concluded that because the vertical component of ground motion causes significant hydrodynamic forces in the horizontal direction on a vertical upstream face, responses to the vertical component of ground motion are of special importance in analysis of concrete gravity dams subjected to earthquakes.  相似文献   

6.
An analysis procedure in the frequency domain is developed for determining the earthquake response of two-dimensional concrete gravity and embankment dams including hydrodynamic effects; responses of the elastic dams and compressible water are assumed linear. The dam and fluid domain are treated as substructures and modelled with finite elements. The only geometric restriction is that an infinite fluid domain must maintain a constant depth beyond some point in the upstream direction. For such an infinite uniform region, a finite element discretization over the depth is combined with a continuum representation in the upstream direction. The fluid domain model approximately accounts for interaction between the fluid and underlying foundation medium through a damping boundary condition applied along the reservoir bottom, while the dam foundation is assumed rigid. Several examples are presented to demonstrate the accuracy of the fluid domain model and to illustrate dam responses obtained from the analysis procedure.  相似文献   

7.
汶川地震震损水库土坝动力反应与几何坝形的经验关系   总被引:1,自引:0,他引:1  
在5·12汶川地震后的四川省水库土坝震害调查成果的基础上,选取汶川地震中受损的有完整资料的96座水库土坝为研究对象,应用等效线性模型对土坝进行了二维动力反应分析。选择3条有代表性的汶川地震实测记录,以三水准峰值加速度输入,得到土坝的动力反应(放大系数、最大动剪应力)与土坝几何形状(宽高比、上游坡比、坝高)间的经验关系。结果表明,土坝放大系数和最大动剪应力随着宽高比和上游坡比的增大而减小,随着坝高的增大而增大;输入波的频谱和峰值强度均对土坝动力反应与其几何形状的经验关系有重要影响。  相似文献   

8.
The linear response of a selected arch dam to harmonic upstream, vertical or cross-stream ground motion is presented for a wide range of the important system parameters characterizing the properties of the dam, foundation rock, impounded water and reservoir boundary materials. Based on these frequency-response functions, the dam-foundation rock interaction effects in the dynamic response of arch dams are investigated.  相似文献   

9.
Vibration tests were conducted on a 1/24-scale model of the North Fork Dam, a double-curvature arch dam, to determine natural frequencies, mode shapes and hydrodynamic pressures. The mode shapes and natural frequencies were determined from tests using two vibrators mounted on the crest of the dam. Hydrodynamic pressures at the dam/reservoir interface were determined from tests in which the vibrator was attached to the downstream foundation of the dam. The hydrodynamic pressures calculated using Westergaard's theory and a theory for arch dams developed by Perumalswami and Kar accurately predicted the measured pressure at frequencies below the first mode frequency of the dam. The differences in the two theories were insignificant. The Structural Analysis Program (SAP), a linear three-dimensional (3-D) finite element code, was used to compute mode shapes and frequencies for the dam with its base fixed and with a foundation. Numerical solution schemes used in the finite element analysis consisted of a Ritz analysis and a subspace iteration method. Calculations were conducted for both full and empty reservoir conditions. The accuracy of the Ritz analysis improved considerably as more nodes in flexible regions of the dam were loaded. However, the lowest eigenvalues were computed using the subspace iteration method. For the full reservoir, the natural frequencies decreased by 20-30 per cent when the foundation was included in the finite element model. The difference was less when the reservoir was empty. The calculations using the subspace iteration scheme and including the foundation agreed closely with experimental mode shapes and corresponding natural frequencies.  相似文献   

10.
The dynamics of a coupled concrete gravity dam-intake tower–reservoir water–foundation rock system is numerically studied considering two hollow slender towers submerged in reservoir of gravity dam. The system is investigated in the frequency-domain using frequency response functions of the dam and the towers, and in the time-domain using time-history seismic analysis under a real earthquake ground motion. The analyzes are separately conducted under horizontal and vertical ground motions. The coupled system is three-dimensionally modeled using finite elements by Eulerian–Lagrangian approach. It is shown that presence of the dam significantly influences the dynamic response of the towers under both horizontal and vertical excitations; however the dam is not affected by the towers. When the dam is present in the model, the water contained inside the towers has different effects if the foundation is rigid, but it alleviates the towers motion if the foundation is flexible. It is concluded that the effects of foundation interaction are of much importance in the response of tall slender towers when they are located near concrete gravity dams.  相似文献   

11.
A nonlinear finite element model for earthquake response analysis of arch dam–water–foundation rock systems is proposed in this paper. The model includes dynamic dam–water and dam–foundation rock interactions, the opening of contraction joints, the radiation damping of semi‐unbounded foundation rock, the compressibility of impounded water, and the upstream energy propagating along the semi‐unbounded reservoir. Meanwhile, a new equivalent force scheme is suggested to achieve free‐field input in the model. The effects of the earthquake input mechanism, joint opening, water compressibility, and radiation damping on the earthquake response of the Ertan arch dam (240 m high) in China are investigated using the proposed model. The results show that these factors significantly affect the earthquake response of the Ertan arch dam. Such factors should therefore be considered in the earthquake response analysis and earthquake safety evaluation of high arch dams. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
The seismic response of a dam is strongly influenced by its interaction with the water reservoir and the foundation. The hydrodynamic forces in the reservoir are in turn affected by radiation of waves towards infinity, wave absorption at the reservoir bottom, and cross-coupling between the foundation below the dam and the reservoir bottom. The fluid–foundation interaction effect, i.e. the wave absorption along the reservoir bottom, can be accounted for by using either an approximate one-dimensional (1D) wave propagation model or a rigorous analysis of interaction between the flexible soil along the base and the water. The rigorous approach requires enormous computational effort because of (a) cross-coupling between the foundation of the dam and the soil below the reservoir and (b) frequency dependence of the boundary condition along the fluid-foundation interface. The analysis can be simplified by ignoring the cross-coupling and by using the approximate 1D wave propagation model. The effects of each of these two simplifications on the accuracy and computational efficiency of the procedure used for the seismic response analysis of a dam are examined. Analytical results are presented for the complex frequency-response functions as well as the time histories of the response of Pine Flat dam to Taft and E1 Centro ground motions.  相似文献   

13.
In this paper, a systematic investigation into the effect of both the type of impervious members and the reservoir bottom sediment on the dynamic response of embankment dams has been carried out using the finite and infinite element coupled method. It has been demonstrated from the numerical results that: (1) the resonant frequencies of an embankment dam—foundation system with an upstream inclined concrete apron are different from those with a central clay core; (2) the type of impervious members has a significant influence on the amplification factors of the system in the low frequency range of excitation, but has little effect in the high frequency range of excitation; (3) the foundation material of an embankment dam affects the dynamic response of the dam drastically; (4) the inclusion of the reservoir bottom sediment has a considerable effect on amplification factors of embankment dams in the case of P-wave incidences, but has little influence in the case of SV-wave vertical incidences; and (5) the reservoir bottom sediment also has a profound effect on the deformed shape of the embankment dam for both P-wave and SV-wave incidences.  相似文献   

14.
The joint between concrete slab and rockfill is designed as welded contact in the classical modeling of concrete-faced rockfill (CFR) dams and earthquake response of the CFR dams is determined by this method. In this study, linear and nonlinear response of Torul CFR Dam including interface element between concrete slab and rockfill were investigated for the duration of strong seismic excitation. The finite element analyses were performed by employing both cases, empty and full reservoir, to research the effect of the reservoir water on the earthquake response of the dam. The reservoir water was modeled with fluid finite elements by the Lagrangian approach. The Drucker-Prager model was used in nonlinear analyses for concrete slab, rockfill and soil materials. According to finite element analyses, displacement and stress components were increased by hydrodynamic pressure. The nonlinear response of the concrete slab was monitored about the peak ground acceleration (pga). This study reveals that the size of sliding zone increases with increasing acceleration amplitudes.  相似文献   

15.
The seismic response of the intake–outlet towers has been widely analyzed in recent years. The usual models consider the hydrodynamic effects produced by the surrounding water and the interior water, characterizing the dynamic response of the tower–water–foundation–soil system. As a result of these works, simplified added mass models have been developed. However, in all previous models, the surrounding water is assumed to be of uniform depth and to have infinite extension. Consequently, the considered added mass is associated with only the pressures created by the displacements of the tower itself. For a real system, the intake tower is usually located in proximity to the dam and the dam pressures may influence the equivalent added mass. The objective of this paper is to investigate how the response of the tower is affected by the presence of the dam. A coupled three‐dimensional boundary element‐finite element model in the frequency domain is employed to analyze the tower–dam–reservoir interaction problem. In all cases, the system response is assumed to be linear, and the effect of the internal fluid and the soil–structure interaction effects are not considered. The results suggest that unexpected resonance amplifications can occur due to changes in the added mass for the tower as a result of the tower–dam–reservoir interaction. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
The seismic behavior of tall concrete face rockfill dams in narrow canyons is investigated, based on numerical simulation of the staged construction, creep settlements, reservoir impoundment and seismic shaking of the dam. The study takes into account the flexibility of the canyon rock, the hydrodynamic effects and potential dynamic rockfill settlements. The static analysis uses a hyperbolic model for the rockfill, whereas the dynamic analysis uses a nonlinear hysteretic model, which accounts for the initial dynamic stiffness and produces hysteresis loops in agreement with the experimental data regarding the shear modulus and damping ratio. A damage plasticity model is used for the reinforced concrete, whereas frictional contact behavior is considered at the base and vertical walls of the concrete slab panels. An existing 150-m-high dam is used to investigate some key issues on the seismic behavior of such dams subjected to upstream−downstream and vertical excitation. Emphasis is placed on the evaluation of the tensile stresses within the slab panels, the compressive stresses at the slab-to-slab vertical interfaces and the opening of the joints. Moreover, the effect of potential dynamic settlements on both the slab stresses and joint openings is investigated. Recommendations for increasing the dam safety and reducing the water leakage through the dam body are given.  相似文献   

17.
调查、搜集和研究了汶川地震中被评定为高危以上险情的147座小型水库土坝的地震破坏情况,给出了高危以上险情土坝的地震破坏程度划分为中等破坏、严重破坏和极严重破坏三个等级的原则和标准,以及土坝的地震破坏程度与地震烈度、土坝的宽高比、上游坡比、坝高的经验关系表,可发现:土坝的几何形状对其破坏程度起着重要的作用;对于6~8度地震烈度区,土坝的宽高比越小,或上游坡比越小,或坝体越高,则土坝的破坏程度越严重;对于9度以上地震烈度区,土坝通常发生极严重破坏。依据高危以上险情土坝的地震反应分析结果,给出了土坝地震破坏程度与土坝宽高比、坝高、土坝上游坡比及坝顶加速度放大系数、坝体最大动剪应力的经验关系曲线,发现在相同的地震烈度水平下,土坝的宽高比越小,或上游坡比越小,或坝高越大,且坝顶加速度放大系数越大或坝体最大动剪应力越大,则其地震破坏程度越严重;坝体最大动剪应力超过30kPa的土坝,通常发生严重或极严重破坏,坝体最大动剪应力大于100kPa的土坝,通常发生极严重破坏;土坝离发震断层越远,则其坝顶加速度放大系数越大。本文给出的高危以上险情土坝的地震破坏程度与坝体几何形状的经验关系,可为今后土坝抗震设计提供参考依据。  相似文献   

18.
The investigation on the seismic behavior of dams becomes crucial but is limited to lack of experimental or field data. This paper aims to experimentally simulate two major dam types of earth-core rock-fill dam and concrete-faced rock-fill dam by dynamic centrifuge tests to investigate the seismic response of the dam. A series of staged centrifuge tests was performed by applying real earthquake records from 0.05 to 0.5g. The distributions of amplification ratio differed depending on the magnitude of earthquake loading and the zoning condition. The amplification ratio at the crest increased in the bedrock acceleration that exceeds 0.3g and strongly influenced by the loosening behavior of the upper part. The residual settlements and horizontal displacement at the dam crest were small. Shallow surface sliding was dominant failure. The maximum tensile stress on the face slab by dynamic loading occurred at a height of around 4/5 near the upstream water level. Finally, two-dimensional numerical simulations were performed in an effort to simulate the centrifuge models. The centrifuge tests and numerical analysis obtained mostly comparable results, thus confirming that centrifuge modeling reasonably simulates the seismic behavior of dams.  相似文献   

19.
An approximate analytical solution is presented for earthquake-induced hydrodynamic pressures on rigid gravity dams with a finite reservoir and incompressible fluid. Using the Trefftz-Mikhlin method, the solution is constructed with function expansions of solutions of the problem's governing equation which satisfy boundary conditions at the bottom and free surface. Unknown coefficients of the linear combinations are obtained from a continuous least-squares treatment of the remaining boundary conditions at the upstream dam face and reservoir wall. Numerical results are presented for different geometries of the dam-water and wall-water interfaces. Out-of-phase motion at the end of the reservoir is considered. When the upstream dam face and reservoir wall are vertical, the known solution for in-phase dam and wall movement is recovered.  相似文献   

20.
以显示动力学和接触碰撞理论为基础,应用ANSYS/LS-DYNA程序,对常规的泥石流重力拦挡坝和带支撑的新型拦挡坝进行了单个球体撞击下的多参数数值模拟计算及对比分析。结果表明:无论有无支撑,混凝土坝身的破坏模式均为由撞击区域应力骤增导致的局部混凝土压碎,但支撑使坝身迎击面应力分布均匀,提高了材料利用率;支撑能够显著减小混凝土坝顶动位移,最大减幅在30%以上,甚至可达近65%,坝身刚度得到大幅度提高;当撞击高度一定时,支撑间距越小,混凝土坝顶动位移越小;若设置了支撑,则可适当减小混凝土坝身厚度,其减小比例以1/3为宜;撞击力主要由混凝土坝身承担,其刚度显著大于支撑总刚度;撞击高度越高或者支撑间距越小,则混凝土坝底支反力所占比重相对越低,支撑的加强作用也就越显著。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号