首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
为了对混凝土框架结构的地震破坏机制和抗震性能进行控制,在框架柱中配置高强钢筋,并将纤维增强混凝土(FRC)用于框架结构的预期损伤部位。结构柱中的高强钢筋用来减小结构的残余变形,FRC材料用来增加结构的耗能能力和损伤容限。设计了三个框架,采用动力弹塑性时程分析方法进行分析。研究结果表明,采用高强钢筋提高了结构的整体承载能力,在层间侧移角达到3%之前避免了柱铰的出现(包括底层柱底),并且减小了结构的残余变形;预期损伤部位采用FRC材料能够提高结构的塑性耗能。  相似文献   

2.
This study presents a nonlinear modelling technique for reinforced concrete (RC) frames retrofitted with metallic yielding devices to predict the seismic response using a computer software OpenSees. The numerical model considers the axial–flexure interaction, shear force–displacement response and the bond-slip characteristics of the frame members. The predicted hysteretic response has been compared with the results of slow-cyclic testing. The validated numerical model is then used to predict the seismic response of a five-story RC frame with soft-story. Nonlinear cyclic pushover and dynamic analyses are conducted to investigate the effectiveness of the proposed retrofitting scheme in enhancing the lateral strength and energy dissipation potential and in controlling the premature failure of the study frame. Analysis results showed significant improvement in the seismic response of RC frames with soft-story using the proposed retrofitting technique.  相似文献   

3.
The response of low‐ductility reinforced concrete (RC) frames, designed typically for a non‐seismic region, subjected to two frequencies of base excitations is studied. Five half‐scaled, two‐bay, two‐storey, RC frames, each approximately 5 m wide by 3.3 m high, were subjected to both horizontal and/or vertical base excitations with a frequency of 40 Hz as well as a lower frequency of about 4 Hz (close to the fundamental frequency) using a shake table. The imposed acceleration amplitude ranged from 0.2 to 1.2g. The test results showed that the response characteristics of the structures differed under high‐ and low‐frequency excitations. The frames were able to sustain high‐frequency excitations without damage but were inadequate for low‐frequency excitations, even though the frames exhibited some ductility. Linear‐elastic time‐history analysis can predict reasonably well the structural response under high‐frequency excitations. As the frames were not designed for seismic loads, the reinforcement detailing may not have been adequate, based on the crack pattern observed. The effect of vertical excitation can cause significant additional forces in the columns and moment reversals in the beams. The ‘strong‐column, weak‐beam’ approach for lateral load RC frame design is supported by experimental observations. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
A simplified design procedure (SDP) for preliminary seismic design of frame buildings with structural dampers is presented. The SDP uses elastic‐static analysis and is applicable to structural dampers made from viscoelastic (VE) or high‐damping elastomeric materials. The behaviour of typical VE materials and high‐damping elastomeric materials is often non‐linear, and the SDP idealizes these materials as linear VE materials. With this idealization, structures with VE or high‐damping elastomeric dampers can be designed and analysed using methods based on linear VE theory. As an example, a retrofit design for a typical non‐ductile reinforced concrete (RC) frame building using high‐damping elastomeric dampers is developed using the SDP. To validate the SDP, results from non‐linear dynamic time history analyses (NDTHA) are presented. Results from NDTHA demonstrate that the SDP estimates the seismic response with sufficient accuracy for design. It is shown that a non‐ductile RC frame building can be retrofit with high‐damping elastomeric dampers to remain essentially elastic under the design basis earthquake (DBE). Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
This paper presents the seismic behaviour of a concentrically braced frame system with self‐centring capability, in which a special type of bracing element termed reusable hysteretic damping brace (RHDB) is used. The RHDB is a passive energy dissipation device with its core energy‐dissipating component made of superelastic Nitinol wires. Compared with conventional bracing in steel structures, RHDB has a few prominent performance characteristics: damage free under frequent and design basis earthquakes in earthquake prone areas; minimal residual drifts due to the self‐centring capability of RHDB frame; and ability to survive several strong earthquakes without the need for repair or replacement. This paper also includes a brief discussion of the RHDB's mechanical configuration and analytical model for RHDB. The seismic performance study of RHDB frame was carried out through a non‐linear time history analysis of 3‐storey and 6‐storey RHDB frame buildings subjected to two suites of 20 earthquake ground motions. The analysis results were compared with buckling‐restrained brace (BRB) frames. This study shows that RHDB frame has a potential to outperform BRB frames by eliminating the residual drift problem. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

6.
Earthquake-induced building collapse and progressive collapse due to accidental local failure of vertical components are the two most common failure modes of reinforced concrete (RC) frame structures. Conventional design methods usually focus on the design requirements of a specific hazard but neglect the interactions between different designs. For example, the progressive collapse design of an RC frame often yields increased reinforcement and flexural strength of the beams. As a result, the seismic design principle of “strong-column-weak-beam” may be violated, which may lead to unfavorable failure modes and weaken the seismic performance. To avoid these adverse effects of the progressive collapse design on the seismic resistance of RC frames, a novel structural detailing is proposed in this study. The proposed detailing technique intends to concurrently improve the seismic and progressive collapse performances of an RC frame by changing the layout of the newly added longitudinal reinforcement against progressive collapse without introducing any additional reinforcement. A six-story RC frame is used as the prototype building for this investigation. Both cyclic and progressive collapse tests are conducted to validate the performance of the proposed structural detailing. Based on the experimental results, detailed finite element (FE) models of the RC frame with different reinforcement layouts are established. The seismic and progressive collapse resistances of different models are compared based on the incremental dynamic analysis (IDA) and nonlinear dynamic alternate path (AP) methods, respectively. The results indicate that the proposed structural detailing can effectively resolve the conflict between the seismic and progressive collapse designs.  相似文献   

7.
The seismic response of non‐ductile reinforced concrete (RC) buildings can be affected by the behaviour of beam‐column joints involved in the failure mechanism, especially in typical existing buildings. Conventional modelling approaches consider only beam and column flexibility, although joints can provide a significant contribution also to the overall frame deformability. In this study, the attention is focused on exterior joints without transverse reinforcement, and a possible approach to their modelling in nonlinear seismic analysis of RC frames is proposed. First, experimental tests performed by the authors are briefly presented, and their results are discussed. Second, these tests, together with other tests with similar features from literature, are employed to calibrate the joint panel deformability contribution in order to reproduce numerically the experimental joint shear stress–strain behaviour under cyclic loading. After a validation phase of this proposal, a numerical investigation of the influence of joints on the seismic behaviour of a case study RC frame – designed for gravity loads only – is performed. The preliminary failure mode classification of the joints within the analysed frame is carried out. Structural models that (i) explicitly include nonlinear behaviour of beam‐column joints exhibiting shear or anchorage failure or (ii) model joints as elements with infinite strength and stiffness are built and their seismic performance are assessed and compared. A probabilistic assessment based on nonlinear dynamic simulations is performed by means of a scaling approach to evaluate the seismic response at different damage states accounting for uncertainties in ground‐motion records. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
地震作用会造成钢筋混凝土框架发生平面和垂直方向的变形,导致其结构受到更大的地震力,加剧损伤程度。形状记忆合金(SMA)材料在外力作用下能够快速恢复变形前形状,降低框架损伤程度,进一步提高框架结构的承载能力和稳定性。基于此,有必要研究形状记忆合金混凝土框架建筑的抗震性能。以某实际工程为例,采用ANSYS软件建立钢筋混凝土框架有限元模型,选取天津地震波、北岭地震波、印度洋地震波及人工地震波作为地震震动输入,记录地震震动下时程结果。研究结果表明,预应力筋断裂后,该结构在地震作用下的滞回曲线为饱满的旗帜形,最大层间位移为1/125,残余变形在±10 mm之间,最高峰值荷载为211 kN,水平承载力较强,表明其自复位性能较高、地震响应效果较优、抗震承载力较强,可以有效提高建筑结构的安全性和可靠性。  相似文献   

10.
Self‐centering reinforced concrete frames are developed as an alternative of traditional seismic force‐resisting systems with better seismic performance and re‐centering capability. This paper presents an experimental and computational study on the seismic performance of self‐centering reinforced concrete frames. A 1/2‐scale model of a two‐story self‐centering reinforced concrete frame model was designed and tested on the shaking table in State Key Laboratory of Disaster Reduction in Civil Engineering at Tongji University to evaluate the seismic behavior of the structure. A structural analysis model, including detailed modeling of beam–column joints, column–base joints, and prestressed tendons, was constructed in the nonlinear dynamic modeling software OpenSEES. Agreements between test results and numerical solutions indicate that the designed reinforced concrete frame has satisfactory seismic performance and self‐centering capacity subjected to earthquakes; the self‐centering structures can undergo large rocking with minor residual displacement after the earthquake excitations; the proposed analysis procedure can be applied in simulating the seismic performance of self‐centering reinforced concrete frames. To achieve a more comprehensive evaluation on the performance of self‐centering structures, research on energy dissipation devices in the system is expected. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
A series of large‐scale real‐time hybrid simulations (RTHSs) are conducted on a 0.6‐scale 3‐story steel frame building with magneto‐rheological (MR) dampers. The lateral force resisting system of the prototype building for the study consists of moment resisting frames and damped brace frames (DBFs). The experimental substructure for the RTHS is the DBF with the MR dampers, whereas the remaining structural components of the building including the moment resisting frame and gravity frames are modeled via a nonlinear analytical substructure. Performing RTHS with an experimental substructure that consists of the complete DBF enables the effects of member and connection component deformations on system and damper performance to be accurately accounted for. Data from these tests enable numerical simulation models to be calibrated, provide an understanding and validation of the in‐situ performance of MR dampers, and a means of experimentally validating performance‐based seismic design procedures for real structures. The details of the RTHS procedure are given, including the test setup, the integration algorithm, and actuator control. The results from a series of RTHS are presented that includes actuator control, damper behavior, and the structural response for different MR control laws. The use of the MR dampers is experimentally demonstrated to reduce the response of the structure to strong ground motions. Comparisons of the RTHS results are made with numerical simulations. Based on the results of the study, it is concluded that RTHS can be conducted on realistic structural systems with dampers to enable advancements in resilient earthquake resistant design to be achieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
A new method of retrofitting reinforced concrete (RC) frames with buckling‐restrained braces (BRBs) to improve frame strength, stiffness and energy dissipation is proposed. Instead of typical post‐installed anchors, load is transferred between the BRB and RC frame through compression bearing between an installed steel frame connected to the BRB, and high‐strength mortar blocks constructed at the four corners of the RC frame. This avoids complex on‐site anchor installation, and does not limit the allowable brace force by the anchor strength. Cyclic displacements of increasing amplitudes were imposed on two RC frame specimens retrofitted with different BRB strength capacities. In one of the frames, the bearing blocks were reinforced with wire mesh to mitigate cracking. A third RC frame was also tested as a benchmark to evaluate the retrofit strength and stiffness enhancements. Test results indicate that the proposed method efficiently transferred loads between the BRBs and RC frames, increasing the frame lateral strength while achieving good ductility and energy‐dissipating capacity. When the bearing block was reinforced with wire mesh, the maximum frame lateral strength and stiffness were more than 2.2 and 3.5 times the RC frame without the BRB respectively. The BRB imposes additional shear demands through the bearing blocks to both ends of the RC beam and column member discontinuity regions (D‐regions). The softened strut‐and‐tie model satisfactorily estimated the shear capacities of the D‐regions. A simplified calculation and a detailed PISA3D analysis were shown to effectively predict member demands to within 13.8% difference of the measured test results. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Infill walls, especially those made of masonry, offer some amount of stiffness and strength. Therefore, the effect of infill walls should be considered during the design of RC frames. In this study, an analysis of the recorded ground motion in the Wenchuan earthquake is performed. Then, a numerical model is developed to simulate the infill walls. Finally, nonlinear dynamic analysis is carried out on a RC frame with and without infill walls, respectively, by using CANNY software. Through a comparative analysis, the following conclusions can be drawn. The failure mode of the frame with infill walls is in accordance with the seismic damage failure pattern, which is strong beam and weak column mode. This indicates that the infill walls change the failure pattern of the frame, and it is necessary to consider them in the seismic design of the RC frame. The numerical model presented in this paper can effectively simulate the effect of infill walls on the RC frame.  相似文献   

14.
增大柱端抗弯承载力是抗震"能力设计"措施中引导钢筋混凝土框架结构形成梁铰型有利耗能机构的关键措施。本文以6层确定性钢筋混凝土框架结构为分析对象,通过结构易损性分析评估了不同强柱系数取值对钢筋混凝土框架结构抗震性能的影响。结构易损性分析表明增大柱端抗弯承载力是改善结构抗震性能的有效措施,增大强柱系数提高了结构的变形能力,使不同破坏极限状态之间形成较大的"梯度",对防止强烈地震作用下结构的突然倒塌提供了预示。结构易损性曲线对评估结构抗震性能、选用合适的目标强柱系数提供了量化标准。  相似文献   

15.
钢筋混凝土结构震后损伤鉴定中,最常见的方式是鉴定者观察房屋破坏现象,根据经验给出震损等级。该方法直观高效,但对鉴定者的专业经验要求较高,且鉴定结果的主观差异较大。对此以RC框架柱为对象,开展了基于震损现象的震损量化鉴定方法研究:在RC框架柱震损现象量化试验基础上给出基于构件骨架曲线特征阶段的震损分级方法;对7个RC框架柱试件进行了改进Park-Ang损伤指数分析,建立了RC框架柱损伤指数-震损分级-震损现象的对应关系;基于RC框架柱的试验结果及典型震害编制了RC框架柱震损图集,并给出了使用图集进行框架柱震损鉴定的流程及方法。使用该方法对2个实际震害中的RC框架柱进行了震损鉴定,可为更加客观以及准确地开展钢筋混凝土结构的震损鉴定提供参考。  相似文献   

16.
This paper experimentally investigates the application of damage avoidance design (DAD) philosophy to moment‐resisting frames with particular emphasis on detailing of rocking interfaces. An 80% scale three‐dimensional rocking beam–column joint sub‐assembly designed and detailed based on damage avoidance principles is constructed and tested. Incremental dynamic analysis is used for selecting ground motion records to be applied to the sub‐assembly for conducting a multi‐level seismic performance assessment (MSPA). Analyses are conducted to obtain displacement demands due to the selected near‐ and medium‐field ground motions that represent different levels of seismic hazard. Thus, predicted displacement time histories are applied to the sub‐assembly for conducting quasi‐earthquake displacement tests. The sub‐assembly performed well reaching drifts up to 4.7% with only minor spalling occurring at rocking beam interfaces and minor flexural cracks in beams. Yielding of post‐tensioning threaded bars occurred, but the sub‐assembly did not collapse. The externally attached energy dissipators provided large hysteretic dissipation during large drift cycles. The sub‐assembly satisfied all three seismic performance requirements, thereby verifying the superior performance of the DAD philosophy. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

17.
For the purpose of estimating the earthquake response, particularly the story drift demand, of reinforced concrete (R/C) buildings with proportional hysteretic dampers, an equivalent single‐degree‐of‐freedom (SDOF) system model is proposed. Especially in the inelastic range, the hysteretic behavior of an R/C main frame strongly differs from that of hysteretic dampers due to strength and stiffness degradation in R/C members. Thus, the proposed model, unlike commonly used single‐spring SDOF system models, differentiates the restoring force characteristics of R/C main frame and hysteretic dampers to explicitly take into account the hysteretic behavior of dampers. To confirm the validity of the proposed model, earthquake responses of a series of frame models and their corresponding equivalent SDOF system models were compared. 5‐ and 10‐story frame models were studied as representative of low‐ and mid‐rise building structures, and different mechanical properties of dampers—yield strength and yield deformation—were included to observe their influence on the effectiveness of the proposed model. The results of the analyses demonstrated a good correspondence between estimated story drift demands using the proposed SDOF system model and those of frame models. Moreover, the proposed model: (i) led to better estimates than those given by a single‐spring SDOF system model, (ii) was capable of estimating the input energy demand and (iii) was capable of estimating the total hysteretic energy and the participation of dampers into the total hysteretic energy dissipation, in most cases. Results, therefore, suggest that the proposed model can be useful in structural design practice. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
A nonlinear hysteretic model for the response and local damage analyses of reinforced concrete shear frames subject to earthquake excitation is proposed, and, the model is applied to analyse midbroken reinforced concrete (RC) structures due to earthquake loads. Each storey of the shear frame is represented by a Clough and Johnston hysteretic oscillator with degrading elastic fraction of the restoring force. The local damage is numerically quantified in the domain [0,1] using the maximum softening damage indicators which are defined in closed form based on the variation of the eigenfrequency of the local oscillators due to the local stiffness and strength deterioration. The proposed method of response and damage analyses is illustrated using a sample 5 storey shear frame with a weak third storey in stiffness and/or strength subject to sinusoidal and simulated earthquake excitations for which the horizontal component of the ground motion is modeled as a stationary Gaussian stochastic process with Kanai-Tajimi spectrum, multiplied by an envelope function.  相似文献   

19.
This paper evaluates the hysteretic behavior of an innovative compressed elastomer structural damper and its applicability to seismic‐resistant design of steel moment‐resisting frames (MRFs). The damper is constructed by precompressing a high‐damping elastomeric material into steel tubes. This innovative construction results in viscous‐like damping under small strains and friction‐like damping under large strains. A rate‐dependent hysteretic model for the compressed elastomer damper, formed from a parallel combination of a modified Bouc–Wen model and a non‐linear dashpot is presented. The model is calibrated using test data obtained under sinusoidal loading at different amplitudes and frequencies. This model is incorporated in the OpenSees [17] computer program for use in seismic response analyses of steel MRF buildings with compressed elastomer dampers. A simplified design procedure was used to design seven different systems of steel MRFs combined with compressed elastomer dampers in which the properties of the MRFs and dampers were varied. The combined systems are designed to achieve performance, which is similar to or better than the performance of conventional steel MRFs designed according to current seismic codes. Based on the results of nonlinear seismic response analyses, under both the design basis earthquake and the maximum considered earthquake, target properties for a new generation of compressed elastomer dampers are defined. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake.  相似文献   