首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 236 毫秒
1.
Structural vibration control using active or passive control strategy is a viable technology for enhancing structural functionality and safety against natural hazards such as strong earthquakes and high wind gusts. Both the active and passive control systems have their limitations. The passive control system has limited capability to control the structural response whereas the active control system depends on external power. The power requirement for active control of civil engineering structures is usually quite high. Thus, a hybrid control system is a viable solution to alleviate some of the limitations. In this paper a multi‐objective optimal design of a hybrid control system for seismically excited building structures has been proposed. A tuned mass damper (TMD) and an active mass driver (AMD) have been used as the passive and active control components of the hybrid control system, respectively. A fuzzy logic controller (FLC) has been used to drive the AMD as the FLC has inherent robustness and ability to handle the non‐linearities and uncertainties. The genetic algorithm has been used for the optimization of the control system. Peak acceleration and displacement responses non‐dimensionalized with respect to the uncontrolled peak acceleration and displacement responses, respectively, have been used as the two objectives of the multi‐objective optimization problem. The proposed design approach for an optimum hybrid mass damper (HMD) system, driven by FLC has been demonstrated with the help of a numerical example. It is shown that the optimum values of the design parameters of the hybrid control system can be determined without specifying the modes to be controlled. The proposed FLC driven HMD has been found to be very effective for vibration control of seismically excited buildings in comparison with the available results for the same example structure but with a different optimal absorber. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

2.
地王大厦风振TMD主被动切换混合控制研究   总被引:3,自引:0,他引:3  
本文采用调谐质量阻尼器对地王大厦这一高层建筑在风荷载作用下的顶点位移进行主被动混合控制,即508重现期风荷载作用下用TMD被动控制,1008重现期风荷载作用下切换为TMD主动控制。理论分析和计算表明,这种控制方式造价低,经济效果佳,以较小的能量输入可取得较优的控制效果。  相似文献   

3.
To resolve difficulties encountered by current technology in structural control against earthquakes, this study proposes a novel high‐performance active mass driver (HP‐AMD) system. Based on an active mass driver system, the device is integrated with a mechanical pulley system for stroke amplification to enhance simultaneously efficiency and save power. Meanwhile, an instantaneous optimal direct output feedback control algorithm is derived alongside the hardware development. Numerical simulation is performed using a five‐storey steel frame as the object structure under the 1940 El Centro earthquake. To gain further insight into the HP‐AMD system, the effects of stroke amplification as well as damper weight on system performance are explored. Analysis results demonstrate that the proposed HP‐AMD system is a promising means to improving current active structural control techniques. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

4.
This study proposes a new design method for an active mass damper (AMD) that is based on auto‐regressive exogenous models of a building structure. The proposed method uses the results of system identification in the field of active structural control. The uncontrolled structure is identified as auto‐regressive exogenous models via measurements under earthquake excitation and forced vibration. These models are linked with an equation of motion for the AMD to introduce a state equation and output equation for the AMD–structure interaction system in the discrete‐time space; the equations apply modern control theories to the AMD design. In the numerical applications of a 10‐degree‐of‐freedom building structure, linear quadratic regulator control is used to understand the fundamental characteristics of the proposed design procedure. The feedback control law requires the AMD's acceleration, velocity and stroke; the structure's acceleration; and the ground acceleration as vibration measurements. The numerical examples confirm the high applicability and control effectiveness of the proposed method. One remarkable advantage of the proposed method is that an equation of motion for the structure becomes unnecessary for designing controllers. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
结构振动控制的半主动磁流变质量驱动器(MR-AMD)   总被引:14,自引:1,他引:14  
本文首先提出了一种新型的半主动磁流变质量驱动器(MR-AMD),该装置用磁流变驱动器替代AMD的液压驱动系统;其次采用所提出的半主动控制算法仿真分析了MR-AMD用于结构振动控制的有效性;第三,比较了半主动质量驱动器(MR-AMD)、调谐质量阻尼器(TMD)及主动质量驱动器(AMD)对同一模型结构的控制效果。分析结果表明,MR-AMD作为一种半主动质量驱动器有效地降低了结构的反应,其控制效果虽然不如具有相同质量块参数的AMD但却优于TMD,且同AMD一样具有较宽的有效频带范围。  相似文献   

6.
Servo‐hydraulic actuators have been widely used for experimental studies in engineering. They can be controlled in either displacement or force control mode depending on the purpose of a test. It is necessary to control the actuators in real time when the rate‐dependency effect of a test specimen needs to be accounted for under dynamic loads. Real‐time hybrid simulation (RTHS) and effective force testing (EFT) method, which can consider the rate‐dependency effect, have been known as viable alternatives to the shake table testing method. Due to the lack of knowledge in real‐time force control, however, the structures that can be tested with RTHS and EFT are fairly limited. For instance, satisfying the force boundary condition for axially stiff members is a challenging task in RTHS, while EFT has a difficulty to be implemented for nonlinear structures. In order to resolve these issues, this paper introduces new real‐time force control methods utilizing the adaptive time series (ATS) compensator and compliance springs. Unlike existing methods, the proposed force control methods do not require the structural modeling of a test structure, making it easy to be implemented especially for nonlinear structures. The force tracking performance of the proposed methods is evaluated for a small‐scale steel mass block system with a magneto‐rheological damper subjected to various target forces. Accuracy, time delay, and resonance response of these methods are discussed along with their force control performance for an axially stiff member. Overall, a satisfactory force tracking performance was observed by using the proposed force control methods.  相似文献   

7.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
Passive and semi‐active tuned mass damper (PTMD and SATMD) building systems are proposed to mitigate structural response due to seismic loads. The structure's upper portion self plays a role either as a tuned mass passive damper or a semi‐active resetable device is adopted as a control feature for the PTMD, creating a SATMD system. Two‐degree‐of‐freedom analytical studies are employed to design the prototype structural system, specify its element characteristics and effectiveness for seismic responses, including defining the resetable device dynamics. The optimal parameters are derived for the large mass ratio by numerical analysis. For the SATMD building system the stiffness of the resetable device design is combined with rubber bearing stiffness. From parametric studies, effective practical control schemes can be derived for the SATMD system. To verify the principal efficacy of the conceptual system, the controlled system response is compared with the response spectrum of the earthquake suites used. The control ability of the SATMD scheme is compared with that of an uncontrolled (No TMD) and an ideal PTMD building systems for multi‐level seismic intensity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A semi‐active fuzzy control strategy for seismic response reduction using a magnetorheological (MR) damper is presented. When a control method based on fuzzy set theory for a structure with a MR damper is used for vibration reduction of a structure, it has an inherent robustness, and easiness to treat the uncertainties of input data from the ground motion and structural vibration sensors, and the ability to handle the non‐linear behavior of the structure because there is no longer the need for an exact mathematical model of the structure. For a clipped‐optimal control algorithm, the command voltage of a MR damper is set at either zero or the maximum level. However, a semi‐active fuzzy control system has benefit to produce the required voltage to be input to the damper so that a desirable damper force can be produced and thus decrease the control force to reduce the structural response. Moreover, the proposed control strategy is fail‐safe in that the bounded‐input, bounded‐output stability of the controlled structure is guaranteed. The results of the numerical simulations show that the proposed semi‐active control system consisting of a fuzzy controller and a MR damper can be beneficial in reducing seismic responses of structures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

10.
In this paper a predictive control method especially suitable for the control of semi‐active friction dampers is proposed. By keeping the adjustable slip force of a semi‐active friction damper slightly lower than the critical friction force, the method allows the damper to remain in its slip state throughout an earthquake of arbitrary intensity, so the energy dissipation capacity of the damper can be improved. The proposed method is formulated in a discrete‐time domain and cast in the form of direct output feedback for easy control implementation. The control algorithm is able to produce a continuous and smooth slip force for a friction damper and thus avoid exerting the high‐frequency structural response that usually exists in structures with conventional friction dampers. Using a numerical study, the control performance of a multiple degrees of freedom (DOF) structural system equipped with passive friction dampers and semi‐active dampers controlled by the proposed method are compared. The numerical case shows that by merely using a single semi‐active friction damper and a few sensors, the proposed method is able to achieve better acceleration reduction than the case using multiple passive dampers. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

11.
In most of the research work on structural vibration control only two‐dimensional plane structural modelling has been considered, although only a few practical building structures can be modelled as planar structures. Therefore, these methods are not directly applicable to the majority of the practical building structures. This paper discusses the design of a multiobjective optimal fuzzy logic controller (FLC) driven hybrid mass damper (HMD) system for seismically excited torsionally coupled building structures. Floor acceleration and velocity information have been used as feedback to the fuzzy logic controller. A three branch tournament Genetic Algorithm has been used for the multiobjective optimal design of the FLC driven HMD system, where the minimization of the non‐dimensionalized peak displacement, acceleration and rotation of the structure about its vertical axis, have been as the three objective functions. The proposed multiobjective optimal fuzzy logic controller has been verified for an example problem reported in the literature. This HMD system consists of four HMDs arranged in such a way that the system can control the torsional mode of vibration effectively in addition to the flexure modes of vibration. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

12.
A semi‐active hydraulic damper (SHD) for a semi‐active damper system, which is useful for practical structural control especially for large earthquakes, has been developed. Its maximum damping force is set to 1 or 2 MN, and it is controlled by only 70 W of electric power. An SHD with a maximum damping force of 1 MN was applied to an actual building in 1998. This paper first presents the results of a dynamic loading test to confirm the control performance of the SHD. Next, an analytical model of SHDs (SHD model) is constructed with the same concept for two kinds of SHDs based on the test results. Through simulation analyses of the test results using the proposed SHD model, the dynamic characteristics of the SHD can be well represented within practical conditions. Simulation analyses are also carried out using a simple structure model with the SHD model. It is shown that this SHD model can be used to precisely evaluate the control effect of the semi‐active damper system and is useful in practical SHD design under the applied conditions. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

13.
Real‐time substructuring is a method of dynamically testing a structure without experimentally testing a physical model of the entire system. Instead the structure can be split into two linked parts, the region of particular interest, which is tested experimentally, and the remainder which is tested numerically. A transfer system, such as a hydraulic actuator or a shaking table, is used to impose the displacements at the interface between the two parts on the experimental substructure. The corresponding force imposed by the substructure on the transfer system is fed back to the numerical model. Control of the transfer system is critical to the accuracy of the substructuring process. A study of two controllers used in conjunction with the University of Bristol shaking table is presented here. A proof‐of‐concept one degree‐of‐freedom mass–spring–damper system is substructured such that a portion of the mass forms the experimental substructure and the remainder of the mass plus the spring and the damper is modelled numerically. Firstly a linear controller is designed and tested. Following this an adaptive substructuring strategy is considered, based on the minimal control synthesis algorithm. The deleterious effect of oil‐column resonance common to shaking tables is examined and reduced through the use of filters. The controlled response of the experimental specimen is compared for the two control strategies. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
A systematic design procedure and an algorithm are devised for variable gain feedback (VGF) control of buildings with active mass damper (AMD) systems. The limit of the stroke length of the auxiliary mass, which is considered to be one of the most important physical constraints for application of AMD systems to actual structures, is studied. A set of variable feedback gains is designed as a function of a single variable that indicates a trade-off between the reduction of the building response and the amplitude of the auxiliary mass stroke, and this variable is on-line controlled to keep the amplitude of the auxiliary mass stroke constant, and within its limits. A design method of static output feedback controller for modal control of buildings with non-classical damping is also presented. Next, an efficient control method for hybrid structural control is developed, with combined use of the VGF control and the static output feedback control. It is shown through numerical examples that the proposed control method effectively adapts the control performance according to the variation in the intensity level of the external excitations in such a manner that the amplitude of the auxiliary mass stroke is kept within its limits and the control power is restrained as well. The application range of the AMD systems is thereby improved significantly. © 1997 John Wiley & Sons, Ltd.  相似文献   

15.
This study investigates an electric‐type active mass driver (AMD) system for structural vibration control. Composed primarily of an electric servomotor and a ball screw, the electrical AMD system is free from noise problems, oil leakage, and labor‐intensive maintenance that commonly are associated with hydraulic AMD systems. The desired stroke amplification of the mass and the power demand of the servomotor can be adjusted via the ball screw pitch, which in turn affects the effectiveness and efficiency of the system. Meanwhile, an instantaneous optimal direct output feedback control algorithm is adopted. Numerical simulation is performed using a five‐story steel frame as the object structure under the conditions of the 1940 El Centro earthquake. The AMD system proves to be effective and efficient within a certain range of the ball screw pitch. The reductions of the peak responses can reach as high as 70% if properly designed. Requiring only the velocity measurement of the top floor for on‐line feedback control, the proposed control algorithm is recommended for practical implementation. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

16.
The electromagnetic mass damper (EMD) control system, as an innovative active control system to reduce structural vibration, offers many advantages over traditional active mass driver/damper (AMD) control systems. In this paper, studies of several EMD control strategies and bench-scale shaking table tests of a two-story model structure are described. First, two structural models corresponding to uncontrolled and Zeroed cases are developed, and parameters of these models are validated through sinusoidal sweep tests to provide a basis for establishing an accurate mathematical model for further studies. Then, a simplified control strategy for the EMD system based on the pole assignment control algorithm is proposed. Moreover, ideal pole locations are derived and validated through a series of shaking table tests. Finally, three benchmark earthquake ground motions and sinusoidal sweep waves are imposed onto the structure to investigate the effectiveness and feasibility of using this type of innovative active control system for structural vibration control. In addition, the robustness of the EMD system is examined. The test results show that the EMD system is an effective and robust system for the control of structural vibrations.  相似文献   

17.
本文从控制装置实现角度,研究了调谐质量阻尼控制装置的关键技术,其中包括装置的支撑系统、气压弹簧和液压阻尼器。应用这些技术研究了在地王大厦安装HMD装置控制结构风振响应,解决了地王大厦在风荷载作用下总侧移和层间位移角超出我国规范限值的问题。在准确把握结构动力特性和设计准则的前提下,对控制装置的参数进行了设计。系统仿真分析表明,HMD控制装置在地王大厦上应用可以有效降低结构侧向位移。  相似文献   

18.
Time‐delay is an important issue in structural control. Applications of unsynchronized control forces due to time‐delay may result in a degradation of the control performance and it may even render the controlled structures to be unstable. In this paper, a state‐of‐the‐art review for available methods of time‐delay compensation is presented. Then, five methods for the compensation of fixed time‐delay are presented and investigated for active control of civil engineering structures. These include the recursive response method, state‐augmented compensation method, controllability based stabilization method, the Smith predictor method and the Pade approximation method, all are applicable to any control algorithm to be used for controlled design. Numerical simulations have been conducted for MDOF building models equipped with an active control system to demonstrate the stability and control performance of these time‐delay compensation methods. Finally, the stability and performance of the phase shift method, that is well‐known in civil engineering applications, have also been critically evaluated through numerical simulations. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

19.
Seismic performance attributes of multi‐story passive and semi‐active tuned mass damper (PTMD and SATMD) building systems are investigated for 12‐story moment resisting frames modeled as ‘10+2’ stories and ‘8+4’ stories. Segmented upper portion of the stories are isolated as a tuned mass, and a passive viscous damper or semi‐active resetable device is adopted as energy dissipation strategy. The semi‐active approach uses feedback control to alter or manipulate the reaction forces, effectively re‐tuning the system depending on the structural response. Optimum tuned mass damper control parameters and appropriate matching SATMD configurations are adopted from a companion study on a simplified two‐degree‐of‐freedom system. Statistical performance metrics are presented for 30 probabilistically scaled earthquake records from the SAC project. Time history analyses are used to compute response reduction factors across a wide range of seismic hazard intensities. Results show that large SATMD systems can effectively manage seismic response for multi‐degree‐of freedom systems across a broad range of ground motions in comparison to passive solutions. Specific results include the identification of differences in the mechanisms by which SATMD and PTMD systems remove energy, based on the differences in the devices used. Additionally, variability is seen to be tighter for the SATMD systems across the suites of ground motions used, indicating a more robust control system. While the overall efficacy of the concept is shown the major issues, such as isolation layer displacement, are discussed in detail not available in simplified spectral analyses, providing further insight into the dynamics of these issues for these systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A new seismic design manner, namely building mass damper (BMD), which is inspired from a combination of mid‐story isolation and tuned mass damper design concepts, recently attracts immense attention. It is mainly because that the use of partial structural mass of the building as an energy absorber in the BMD design can overcome the drawback of limited response reduction due to insufficient added tuned mass in the conventional tuned mass damper design. In this study, an optimum BMD (OBMD) design approach, namely optimum dynamic characteristic control approach, based on a simplified 3‐lumped‐mass structure model is proposed to seismically protect both the superstructure (or tuned mass) and the substructure (or primary structure), respectively, above and below the control layer. A series of sensitivity analyses and experimental studies on different parameters, including mass, frequency, and damping ratios, of a building model designed with a BMD system were conducted. The test results verify the practical feasibility of the BMD concept as well as the effectiveness of the proposed OBMD design. Furthermore, by comparing with the numerical results of a mid‐story isolated counterpart, it is demonstrated that the proposed OBMD design can have a comparable and even better control performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号