首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
剪切型结构的抗震强度折减系数研究   总被引:1,自引:0,他引:1  
为了研究剪切型结构抗震强度需求的变化规律,本文基于单自由度体系的非线性时程分析,研究了不同场地条件下延性折减系数与位移延性系数和结构自振周期的关系;采用修正等效单自由度体系位移延性折减系数的方法,研究了剪切型多自由度体系的延性折减系数;以基于中国建筑抗震规范设计的代表不同抗震能力要求的RC框架结构为分析对象,通过静力弹塑性分析,研究了RC框架结构的体系超强能力。分析结果表明场地类别、位移延性水准和结构振动周期对单自由度体系的延性折减系数有显著的影响;多自由度体系的抗震延性折减系数明显比其相应的等效单自由度体系的抗震延性折减系数小;RC框架结构的超强系数一般随结构楼层数的增加而减小,随抗震设防烈度的增大而减小,内框架的超强系数比边框架的超强系数大。  相似文献   

2.
The results of experimental tests carried out on reinforced concrete (RC) full‐scale 2‐storey 2‐bays framed buildings are presented. The unretrofitted frame was designed for gravity loads only and without seismic details; such frame was assumed as a benchmark system in this study. A similar RC frame was retrofitted with buckling‐restrained braces (BRBs). The earthquake structural performance of both prototypes was investigated experimentally using displacement‐controlled pushover static and cyclic lateral loads. Modal response properties of the prototypes were also determined before and after the occurrence of structural damage. The results of the dynamic response analyses were utilized to assess the existing design rules for the estimation of the elastic and inelastic period of vibrations. Similarly, the values of equivalent damping were compared with code‐base relationships. It was found that the existing formulations need major revisions when they are used to predict the structural response of as‐built RC framed buildings. The equivalent damping ratio ξeq was augmented by more than 50% when the BRBs was employed as bracing system. For the retrofitted frame, the overstrength Ω and the ductility µ are 1.6 and 4.1, respectively; the estimated R‐factor is 6.5. The use of BRBs is thus a viable means to enhance efficiently the lateral stiffness and strength, the energy absorption and dissipation capacity of the existing RC substandard frame buildings. The foundation systems and the existing members of the superstructure are generally not overstressed as the seismic demand imposed on them can be controlled by the axial stiffness and the yielding force of the BRBs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
The seismic responses of steel buildings with perimeter moment resisting frames (MRF) with welded connections (WC) are estimated and compared to those of similar buildings with semi-rigid post-tensioned connections (PC). The responses are estimated in terms of ductility reduction factors (R µ,), ductility demands (µ G ) and force reduction factors (R). Two steel model buildings, which were modeled as complex-3D-MDOF systems, were used in the study. Results indicate that the reduction magnitude of global response parameters is larger than that of local response parameters, contradicting the same reduction implicitly assumed in the static equivalent lateral force procedure, implying that non-conservative design may result. The value of 8 for R, suggested in many codes for ductile steel MRF, and the value of 1 suggested in the well known Newmark and Hall procedure for the ratio of R to µ G , cannot be justified. The reason for this is that SDOF systems were used to model actual structures, where higher mode effects, energy dissipation and structural overstrength weren’t explicitly considered. The codes should be more transparent regarding the magnitude and the components involved in the force reduction factors. The seismic performance of steel buildings with PC may be superior to that of the buildings with WC, since their force reduction factors are larger and their ductility demands smaller, implying that PC buildings could be designed for smaller lateral seismic forces. The conclusions of this paper are for the particular structural systems and models considered. Much more research is needed to reach more general conclusions.  相似文献   

4.
It is known that structural stiffness and strength distributions have an important role in the seismic response of buildings.The effect of using different code-specified lateral load patterns on the seismic performance of fixed-base buildings has been investigated by researchers during the past two decades.However,no investigation has yet been carried out for the case of soil-structure systems.In the present study,through intensive parametric analyses of 21,600 linear and nonlinear MDOF systems and considering five different shear strength and stiffness distribution patterns,including three code-specified patterns as well as uniform and concentric patterns subjected to a group of earthquakes recorded on alluvium and soft soils,the effect of structural characteristics distribution on the strength demand and ductility reduction factor of MDOF fixed-base and soil-structure systems are parametrically investigated.The results of this study show that depending on the level of inelasticity,soil flexibility and number of degrees-of-freedoms(DOFs),structural characteristics distribution can significantly affect the strength demand and ductility reduction factor of MDOF systems.It is also found that at high levels of inelasticity,the ductility reduction factor of low-rise MDOF soil-structure systems could be significantly less than that of fixed-base structures and the reduction is less pronounced as the number of stories increases.  相似文献   

5.
A parametric study of 13 608 ductile moment‐resisting steel frames designed according to Eurocodes 3 and 8 is performed. A flowchart for the evaluation of the seismic‐resistant capacity of the designed frames is developed based on the N2 method. The design structural overstrength, ductility supply, plastic redistribution parameter, supply reduction factor and performance ratio of the frames are analysed. We determine that the frames have performance ratios higher than 1, mostly due to high values of design structural overstrength, showing that the seismic supply produced by the restraints of Eurocodes 3 and 8 is always higher than the seismic demand. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

6.
Incremental dynamic analysis and nonlinear static pushover analysis are carried out on a performance-based design to determine the seismic demands and capacities of an elliptic braced moment resisting frame (ELBRF). The objective is to assess ductility, overstrength and response modification factors in a modern steel-braced structural system based on incremental dynamic analysis. This integrated system is connected to a beam and column with an appropriate length while providing enough architectural space to allow for an opening without having the common problems associated with architectural spaces in braced systems. Several different classes of buildings are considered on soil type II. Linear dynamic analysis, nonlinear static pushover analysis and incremental nonlinear dynamic analysis related to 12 records from past earthquakes are carried out using OpenSees software. The factors of ductility, overstrength and response modification are calculated for this system. The values of 9.5 and 6.5 are found and suggested only for the response modification factor for ELBRF systems in allowable stress and ultimate limit state methods, respectively. The fragility curves are plotted for the first time for this type of bracing, which contributes to the assessment of building seismic damage.  相似文献   

7.
This paper assesses the seismic performance of typical reinforced concrete (RC) existing framed structures designed for gravity loads only. The sample two-storey structural system exhibits high vulnerability, i.e. low lateral resistance and limited translation ductility; hence an effective strategy scheme for seismic retrofitting was deemed necessary. Such a scheme comprises buckling restrained braces (BRBs) placed along the perimeter frames of the multi-storey building. The adopted design approach assumes that the global response of the inelastic framed structure is the sum of the elastic frame (primary system) and the system comprising perimeter diagonal braces (secondary system); the latter braces absorb and dissipate a large amount of hysteretic energy under earthquake ground motions. Comprehensive nonlinear static (pushover) and dynamic (response history) analyses were carried out for both the as-built and retrofitted structures to investigate the efficiency of the adopted intervention strategy. A set of seven code-compliant natural earthquake records was selected and employed to perform inelastic response history analyses at serviceability (operational and damageability limit states, OLS and DLS) and ultimate limit states (life safety and collapse prevention limit states, LSLS and CPLS). Both global and local lateral displacements are notably reduced after the seismic retrofit of the existing system. In the as-built structure, the damage is primarily concentrated at the second floor (storey mechanism); the computed interstorey drifts are 2.43% at CPLS and 1.92% at LSLS for modal distribution of lateral forces. Conversely, for the retrofitted system, the estimated values of interstorey drifts (d/h) are halved; the maximum d/h are 0.84% at CPLS (along the Y-direction) and 0.65% at LSLS (yet along the Y-direction). The values of the global overstrength Ω vary between 2.14 and 2.54 for the retrofitted structure; similarly, the translation ductility μΔ-values range between 2.07 and 2.36. The response factor (R- or q-factor) is on average equal to 5.0. It is also found that, for the braced frame, under moderate-to-high magnitude earthquakes, the average period elongation is about 30%, while for the existing building the elongation is negligible (lower than 5%). The inelastic response of the existing structure is extremely limited. Conversely, BRBs are effective to enhance the ductility and energy dissipation of the sample as-built structural system. Extensive nonlinear dynamic analyses showed that more than 60% of input seismic energy is dissipated by the BRBs at ultimate limit states. The estimated maximum axial ductility of the braces is about 10; the latter value of translation ductility is compliant with BRBs available on the market. At DLS, the latter devices exhibit an elastic behaviour. It can thus be concluded that, under moderate and high magnitude earthquakes, the damage is concentrated in the added dampers and the response of the existing RC framed structure (bare frame) is chiefly elastic.  相似文献   

8.
This study investigates the seismic design factors for three reinforced concrete (RC) framed buildings with 4, 16 and 32-stories in Dubai, UAE utilizing nonlinear analysis. The buildings are designed according to the response spectrum procedure defined in the 2009 International Building Code (IBC’09). Two ensembles of ground motion records with 10% and 2% probability of exceedance in 50 years (10/50 and 2/50, respectively) are used. The nonlinear dynamic responses to the earthquake records are computed using IDARC-2D. Key seismic design parameters are evaluated; namely, response modification factor (R), deflection amplification factor (Cd), system overstrength factor (Ωo), and response modification factor for ductility (Rd) in addition to inelastic interstory drift. The evaluated seismic design factors are found to significantly depend on the considered ground motion (10/50 versus 2/50). Consequently, resolution to the controversy of Dubai seismicity is urged. The seismic design factors for the 2/50 records show an increase over their counterparts for the 10/50 records in the range of 200%-400%, except for the Ωo factor, which shows a mere 30% increase. Based on the observed trends, period-dependent R and Cd factors are recommended if consistent collapse probability (or collapse prevention performance) in moment frames with varying heights is to be expected.  相似文献   

9.
Different values have been assigned to the ratio of the defl ection amplifi cation factor(Cd) to the response modifi cation factor(R) for a specifi ed force-resisting system in the seismic design provisions while the same application is defi ned for it. An analytical study of the seismic responses of several reinforced concrete frames subjected to a suite of earthquake records performed in this research indicate that the stories’ overstrength and stiffness distribution along the structural height can affect local defl ections more than global ones. Therefore, the Cd/R ratio is calculated based on the ratio of both maximum inelastic to maximum elastic displacements and interstory drifts. Due to damage concentration in some specifi c stories, the defl ection amplifi cation factor calculated based on inelastic interstory drifts was larger than that of the inelastic displacements. Consequently, a minimum value of 1.0 is recommended for the Cd/R ratio in order to estimate maximum inelastic drifts. The ratio of inelastic to elastic displacement was generally found to increase slightly along the structural height for the studied RC models. In addition, it was detected that the story damage indices of the studied RC frames decrease when the inverted value of inelastic interstory drift ratios are increased through a(negative) power form.  相似文献   

10.
Uneven distribution of seismic demand in asymmetric-plan structures is a critical concern in earthquake-resistant design. Contemporary seismic design strategies that are based on linear elastic response, single load reduction factor, and uniform ductility demand throughout an asymmetric system generally lead to unsatisfactory performance in terms of realized ductilities and nonuniform damage distribution due to strong torsional coupling associated with asymmetric-plan systems. In many cases, actual nonlinear behavior of the structure displays significant deviation from what is estimated by a linear elastic, force-based seismic design approach. This study investigates the prediction of seismic demand distribution among structural members of a single-story, torsionally stiff asymmetric-plan system. The focus is on the effect of inherent unbalanced overstrength, resulting from current force-based design practices, on the seismic response of code-designed single-story asymmetric structures. The results obtained are utilized to compile unsymmetrical response spectra and uniform ductility spectra, which are proposed as assessment and preliminary design tools for estimating the seismic performance of multistory asymmetric structures. A simple design strategy is further suggested for improving the inelastic torsional performance of asymmetric systems. Providing additional strength to stiff edge members over their nominal design strength demands leads to a more balanced ductility distribution. Finally, seismic responses of several asymmetric case study structures designed with the aid of the proposed strategy are assessed for validating their improved performance.  相似文献   

11.
The aim of this work is to propose seismic reliability‐based relationships between the strength reduction factors and the displacement ductility demand of nonlinear structural systems equipped with friction pendulum isolators (FPS) depending on the structural properties. The isolated structures are described by employing an equivalent 2dof model characterized by a perfectly elastoplastic rule to account for the inelastic response of the superstructure, whereas, the FPS behavior is described by a velocity‐dependent model. An extensive parametric study is carried out encompassing a wide range of elastic and inelastic building properties, different seismic intensity levels and considering the friction coefficient as a random variable. Defined a set of natural seismic records and scaled to the seismic intensity corresponding to life safety limit state for L'Aquila site (Italy) according to NTC08, the inelastic characteristics of the superstructures are designed as the ratio between the average elastic responses and increasing strength reduction factors. Incremental dynamic analyses (IDAs) are developed to evaluate the seismic fragility curves of both the inelastic superstructure and the isolation level assuming different values of the corresponding limit states. Integrating the fragility curves with the seismic hazard curves related to L'Aquila site (Italy), the reliability curves of the equivalent inelastic base‐isolated structural systems, with a design life of 50 years, are derived proposing seismic reliability‐based regression expressions between the displacement ductility demand and the strength reduction factors for the superstructure as well as seismic reliability‐based design (SRBD) abacuses useful to define the FPS properties. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
The results of shaking table tests of a series of 1:5 scale masonry building models have been used for the assessment of values of structural behavior factor q for masonry structures, seismic force reduction factors proposed for the calculation of design seismic loads by Eurocode 8, European standard for the design of structures for earthquake resistance. Six models have been tested, representing prototype buildings of two different structural configurations and built with two different types of masonry materials. The study indicated that the reduction of seismic forces for the design depends not only on the type of masonry construction system, but also on structural configuration and mechanical characteristics of masonry materials. It has been also shown that besides displacement and energy dissipation capacity, damage limitation requirement should be taken into account when evaluating the values of behavior factor. On the basis of analysis of experimental results a conclusion can be made, that the values at the upper limit of the proposed range of values of structural behavior factor q for unreinforced and confined masonry construction systems are adequate, if pushover methods are used and the calculated global ductility of the structure is compared with the displacement demand. In the case where elastic analysis methods are used and significant overstrength is expected, the proposed values are conservative. However, additional research and parametric studies are needed to propose the modifications.  相似文献   

13.
School buildings have been classified by many of the design codes as important buildings, which have to withstand the earthquake excitations without any or with minor structural damages, and special care has to be given in their design and construction phases. This paper mainly aims to investigate the seismic performance of reinforced-concrete (RC) school buildings after 2011 Van earthquakes. The seismic performances of two damaged RC school buildings located in the earthquake-affected region are studied. First, the capacities of the selected buildings are assessed using nonlinear static procedures, and then, nonlinear dynamic time history analyses are performed to evaluate the seismic performances of the selected RC school buildings. Reasons for the observed damages are discussed. Further, recommendations are provided from the viewpoint of enhancing the structural capacity of the heavily damaged school building. As a result, to get an idea about the ductility demands imposed on the buildings, spectral acceleration values are compared with the seismic coefficients of the code that the buildings were adapted to. It can be concluded that the construction quality and detailing of the reinforcement are the key issues affecting the seismic performance of RC school buildings.  相似文献   

14.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
In past years, seismic response of asymmetric structures has been frequently analysed by means of single-storey models, because of their simplicity and low computational cost. However, it is widely believed that use of more realistic multi-storey models is needed in order to investigate effects of some system characteristics (such as overstrength, higher modes of vibration, etc.) that make behaviour of multi-storey schemes different from that of single-storey systems. This paper examines effects of the overstrength in element cross-sections on the seismic behaviour of multi-storey asymmetric buildings. It is shown that in actual buildings this characteristic, which is sometimes very variable both in plan and along the height of the building, may lead to distributions of ductility demands different from those expected according to the results from single-storey models. Consequently, torsional provisions, which aim at reducing ductility demands of single-storey asymmetric systems to those of the corresponding torsionally balanced systems, should be re-checked in light of the behaviour of realistic multi-storey buildings.  相似文献   

16.
The seismic design of multi‐story buildings asymmetric in plan yet regular in elevation and stiffened with ductile RC structural walls is addressed. A realistic modeling of the non‐linear ductile behavior of the RC walls is considered in combination with the characteristics of the dynamic torsional response of asymmetric buildings. Design criteria such as the determination of the system ductility, taking into account the location and ductility demand of the RC walls, the story‐drift demand at the softer (most displaced) edge of the building under the design earthquake, the allowable ductility (ultimate limit state) and the allowable story‐drift (performance goals) are discussed. The definition of an eccentricity of the earthquake‐equivalent lateral force is proposed and used to determine the effective displacement profile of the building yet not the strength distribution under the design earthquake. Furthermore, an appropriate procedure is proposed to calculate the fundamental frequency and the earthquake‐equivalent lateral force. A new deformation‐based seismic design method taking into account the characteristics of the dynamic torsional response, the ductility of the RC walls, the system ductility and the story‐drift at the softer (most displaced) edge of the building is presented and illustrated with an example of seismic design of a multi‐story asymmetric RC wall building. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

17.
This paper compares the seismic force reduction factors used in the United States and Japan. Since these factors appear in a very different format in the two countries, for comparison purposes, a general expression relating the force reduction factor to the structural ductility and overstrength factors is first established. This study shows that (i) the seismic design limit state philosophy applied to moderate and severe earthquakes is treated differently in each country; (ii) the Japanese code requires the designer to check explicitly the serviceability limit state, while the American codes do not require the member's strength be checked for the serviceability limit state; (iii) the force reduction factors used in Japan for the ultimate limit state check are significantly smaller than those used in the United States, and (iv) the force reduction factors used in Japan are even smaller if structural overstrength is not explicitly checked by designers.  相似文献   

18.
A computer program is developed to test the influence of the structural overstrength to calibrate seismic codes. The program automatically performs an iterative design-evaluation process to calibrate the seismic code. A numerical example is performed in order to test the different approaches. The virtual simulation shows that the force reduction factor cannot be directly deduced from building performance in past earthquakes. This custom of deducing the force reduction factor from the building performance under past earthquakes artificially increases the ratios elastic spectrum to design spectrum due to the design structural overstrength. The similitude of the simulation with the historical calibration of the design spectrum in the seismic codes in the United States of America (USA) is evident.  相似文献   

19.
Forward directivity may cause large velocity pulses in ground motion time histories that are damaging to buildings at sites close to faults, potentially increasing seismic collapse risk. This study quantifies the effects of forward directivity on collapse risk through incremental dynamic analysis of building simulation models that are capable of capturing the key aspects of strength and stiffness degradation associated with structural collapse. The paper also describes a method for incorporating the effects of near-fault directivity in probabilistic assessment of seismic collapse risk. The analysis is based on a suite of RC frame models that represent both past and present building code provisions, subjected to a database of near-fault, pulse-like ground motions with varying pulse periods. Results show that the predicted collapse capacity is strongly influenced by variations in pulse period and building ductility; pulse periods that are longer than the first-mode elastic building period tend to be the most damaging. A detailed assessment of seismic collapse risk shows that the predicted probability of collapse in 50 years for modern concrete buildings at a representative near-fault site is approximately 6%, which is significantly higher than the 1% probability in the far-field region targeted by current seismic design maps in the US. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A comprehensive parametric study on the inelastic seismic response of seismically isolated RC frame buildings, designed for gravity loads only, is presented. Four building prototypes, with 23 m × 10 m floor plan dimensions and number of storeys ranging from 2 to 8, are considered. All the buildings present internal resistant frames in one direction only, identified as the strong direction of the building. In the orthogonal weak direction, the buildings present outer resistant frames only, with infilled masonry panels. This structural configuration is typical of many existing RC buildings, realized in Italy and other European countries in the 60s and 70s. The parametric study is based on the results of extensive nonlinear response‐time history analyses of 2‐DOF systems, using a set of seven artificial and natural seismic ground motions. In the parametric study, buildings with strength ratio (Fy/W) ranging from 0.03 to 0.15 and post‐yield stiffness ratio ranging from 0% to 6% are examined. Three different types of isolation systems are considered, that is, high damping rubber bearings, lead rubber bearings and friction pendulum bearings. The isolation systems have been designed accepting the occurrence of plastic hinges in the superstructure during the design earthquake. The nonlinear response‐time history analyses results show that structures with seismic isolation experience fewer inelastic cycles compared with fixed‐base structures. As a consequence, although limited plastic deformations can be accepted, the collapse limit state of seismically isolated structures should be based on the lateral capacity of the superstructure without significant reliance on its inherent hysteretic damping or ductility capacity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号