In order to investigate aquifers, several geophysical surveys have been carried out in the Baril area of the southern flank of Piton de la Fournaise volcano on Reunion in the Indian Ocean using audiomagnetotelluric (AMT), very-low-frequency (VLF) and self-potential (SP) methods. We present the results with emphasis on a comparison between SP data and the findings of geoelectric surveys. AMT soundings have indicated, from the surface downward, three layers: (i) resistive volcanic rocks, (ii) an intermediate resistivity layer, and (iii) a conductive basement attributed to a seawater-bearing aquifer. VLF measurements allow the mapping of the first layer apparent resistivity, and therefore its bottom, when the true resistivity is supposed to be isotropic and homogenous. When this assumption does not hold, only the SP method permits the mapping of this bottom. Because of the good agreement between the SP and electromagnetic results, we propose the SP method as the first tool that should be used in studying shallow hydrogeological structures in volcanic areas.  相似文献   

2.
The Las Cañadas caldera of Tenerife (LCC) is a well exposed caldera depression filled with pyroclastic deposits and lava flows from the active Teide–Pico Viejo complex (TPVC). The caldera's origin is controversial as both the formation by huge lateral flank collapse(s) and multiple vertical collapses have been proposed. Although vertical collapses may have facilitated lateral slope failures and thus jointly contribute to the exposed morphology, their joint contribution has not been clearly demonstrated. Using results from 185 audiomagnetotelluric (AMT) soundings carried out between 2004 and 2006 inside the LCC, our study provides consistent geophysical constraints in favour of multiple vertical caldera collapse. One-dimensional modelling reveals a conductive layer at shallow depth (30–1000 m), presumably resulting from hydrothermal alteration and weathering, underlying the infilling resistive top layer. We present the resistivity distribution of both layers (resistivity images), the topography of the conductive layer across the LCC, as well as a cross-section in order to highlight the caldera's evolution, including the distribution of earlier volcanic edifices. The AMT phase anisotropy reveals the structural and radial characteristics of the LCC.  相似文献   

3.
 A study of the geoelectrical structure of the central part of Piton de la Fournaise volcano (Réunion, Indian Ocean) was made using direct current electrical (DC) and transient electromagnetic soundings (TEM). Piton de la Fournaise is a highly active oceanic basaltic shield and has been active for more than half a million years. Joint interpretation of the DC and TEM data allows us to obtain reliable 1D models of the resistivity distribution. The depth of investigation is of the order of 1.5 km but varies with the resistivity pattern encountered at each sounding. Two-dimensional resistivity cross sections were constructed by interpolation between the soundings of the 1D interpreted models. Conductors with resistivities less than 100 ohm-m are present at depth beneath all of the soundings and are located high in the volcanic edifice at elevations between 2000 and 1200 m. The deepest conductor has a resistivity less than 20 ohm-m for soundings located inside the Enclos and less than 60–100 ohm-m for soundings outside the Enclos. From the resistivity distributions, two zones are distinguished: (a) the central zone of the Enclos; and (b) the outer zone beyond the Enclos. Beneath the highly active summit area, the conductor rises to within a few hundred meters of the surface. This bulge coincides with a 2000-mV self-potential anomaly. Low-resistivity zones are inferred to show the presence of a hydrothermal system where alteration by steam and hot water has lowered the resistivity of the rocks. Farther from the summit, but inside the Enclos, the depth to the conductive layers increases to approximately 1 km and is inferred to be a deepening of the hydrothermally altered zone. Outside of the Enclos, the nature of the deep, conductive layers is not established. The observed resistivities suggest the presence of hydrated minerals, which could be found in landslide breccias, in hydrothermally altered zones, or in thick pyroclastic layers. Such formations often create perched water tables. The known occurrence of large eastward-moving landslides in the evolution of Piton de la Fournaise strongly suggests that large volumes of breccias should exist in the interior of the volcano; however, extensive breccia deposits are not observed at the bottom of the deep valleys that incise the volcano to elevations lower than those determined for the top of the conductors. The presence of the center of Piton de la Fournaise beneath the Plaine des Sables area during earlier volcanic stages (ca. 0.5 to 0.150 Ma) may have resulted in broad hydrothermal alteration of this zone. However, this interpretation cannot account for the low resistivities in peripheral zones. It is not presently possible to discriminate between these general interpretations. In addition, the nature of the deep conductors may be different in each zone. Whatever the geologic nature of these conductive layers, their presence indicates a major change of lithology at depth, unexpected for a shield volcano such as Piton de la Fournaise. Received: 3 November 1999 / Accepted: 15 September 1999  相似文献   

4.
Electrical and electromagnetic methods are well suited for coastal aquifer studies because of the large contrast in resistivity between fresh water-bearing and salt water-bearing formations. Interpretation models for these aquifers typically contain four layers: a highly resistive unsaturated zone; a surficial fresh water aquifer of intermediate resistivity; an underlying conductive, salt water saturated aquifer; and resistive substratum. Additional layers may be added to allow for variations in lithology within the fresh water and salt water layers. Two methods are evaluated: direct current resistivity and time domain electromagnetic soundings. Use of each method alone produces nonunique solutions for resistivities and/or thicknesses of the different layers. We show that joint inversion of vertical electric and time domain electromagnetic soundings produces a more tightly constrained interpretation model at three test sites than is produced by inversion methods applied to each data set independently.  相似文献   

5.
Despite its reduced penetration depth, audiomagnetotelluric (AMT) studies can be used to determine a broad range of features related to little studied geothermal fields. This technique requires a stepwise interpretation of results taking into consideration diverse information (e.g. topographic, hydrological, geological and/or structural data) to constrain the characteristics of the study area. In this work, an AMT study was performed at the hot springs in the northern segment of the La Candelaria Range in order to characterize the area at depth. Geometric aspects of the shallow subsurface were determined based on the dimensional and distortion analysis of the impedance tensors. Also, the correlation between structural features and regional strikes allowed us to define two geoelectric domains, useful to determine the controls on fluid circulation. The subsurface resistivity distribution was determined through 1D and 2D models. The patterns of the 1D models were compared with the morpho-structure of the range. Shallow and deep conductive zones were defined and a possible shallow geothermal system scheme proposed. A strong correlation was found between the AMT results and the geological framework of the region, showing the relevance of using AMT in geothermal areas during the early stages of subsurface prospecting.  相似文献   

6.
A tensor magnetotelluric test survey was carried out in the region of Santa Catarina, located in the Chalco sub-basin of the Mexico Basin. The objective was to define the stratification at depth with an emphasis on the geometry of the main aquifer of that region which is partially known from DC resistivity soundings and drilling. High-quality magnetotelluric soundings could be recorded in the immediate vicinity of large urban zones because the sub-surface is very conductive. Interpretation shows that the solid bedrock is located at a depth of at least 800 m to the south and 1300 m to the north; it could, however, be much deeper. Using complementary DC resistivity sounding and well-logging data, three main layers have been defined overlying the bedrock. These layers are, from surface to bottom, an unsaturated zone of sand, volcanic ash and clay about 10 m thick, followed by a very conductive (1.5 ohm·m) 200 m thick layer of sand and ash with intercalated clay, saturated with highly mineralized water, and finally a zone with resistivity increasing gradually to 60 ohm·m. The investigated deep aquifer constitutes most of this third layer. It consists of a sequence of sand, gravel, pyroclastites and mainly fractured basalts. MT resistivity soundings and magnetic transfer functions also indicate that a shallow resistive structure is dipping, from the northwest, into the lacustrine deposits of the basin. This geologic feature is likely to be highly permeable fractured basaltic flows, which provide a channel by which water contaminated by the Santa Catarina landfill may leak into the basin.  相似文献   

7.
Experimental measurements in the Ngatamariki geothermal field, North Island, New Zealand were made to test the applicability of the time domain electromagnetic method for detailed investigation of the resistivity structure within a geothermal field. Low-frequency square wave signals were transmitted through three grounded bipole current sources sited about 8 km from the measurement lines. Despite high levels of electrical noise, transient electric field vectors could be determined reliably for times between 0.02 and 3.3 s after each step in the source current. Instantaneous apparent resistivity tensors were then calculated. Apparent resistivity pseudosections along the two measurement lines show smooth variations of resistivity from site to site. Over most of the field the images consistently show a three-layer resistivity structure with a conductive middle layer (3–10 Ωm) representing the conductive upper part of the thermal reservoir. A deep-seated region of low resistivity in the northwest of the field may indicate a conductive structure at about 1 km associated with a deeper diorite intrusion. Measurements sited closer than about 100 m to drillholes appear to have been disturbed by metallic casing in the holes. A change in resistivity structure in the east of the field may indicate a major geological or hydrothermal boundary.  相似文献   

8.
In the Llucmajor aquifer system (Majorca Island, Spain) some geothermal evidences have appeared. This phenomenon is not isolated to Majorca and it is present in other areas, where it can be associated with structural conditions, especially to the extensional event suffered by the island after the Alpine Orogeny. However, the origin of this anomaly in Llucmajor is not well known, and there is no surface geological evidence of these structural conditions. With the aim of delineating the geoelectrical structure of the zone and identifying the geological structure that allows the presence of this anomaly, an audiomagnetotelluric (AMT) survey was carried out. The AMT data was processed using a Wavelet Transform-based scheme. Dimensionality analysis indicates that the geoelectrical structure is mainly 3D. The 3D model was obtained by trial and error forward modeling, taking accounting of the responses from the determinant of the impedance tensor. The model shows a vertical resistivity distribution with three horizons associated with different units: on the top, a shallow high resistive media related to an unconfined shallow aquifer; in the middle, a conductive layer related to the aquitard, and below it, another resistive media related to the confined deeper aquifer. The intermediate horizon shows a sudden thinning beneath the thermal anomalous zone that can be identified as a weakness zone (fault or fracture) connecting both aquifers. An exploratory well was drilled after the AMT survey and reached almost 700 m in depth. This allowed correlating the resistivity distribution of the 3D model with data logging and lithology obtained from the well, showing a proper agreement between them.  相似文献   

9.
The resistivity structure of the Tenerife geothermal system has been determined by the 3-D inversion of data from different magnetotelluric surveys. In this paper, the ocean and topography effects on the magnetotelluric data were investigated by constructing a 3-D conceptual geoelectrical model of the island. The study showed that these effects should be taken into account in order to obtain a reliable subsurface model of the island. Data from 148 sites were used during three-dimensional inversion. The most interesting feature in the final geoelectrical model of the geothermal system is a low resistivity structure (<10 Ωm) above the resistive core of the system. The low resistivity structure has been interpreted as a hydrothermal clay alteration cap typically generated in the conventional geothermal systems. The resistivity model has been correlated with a recent seismic velocity model, showing that a low resistivity structure surrounds an area with high P wave velocity and medium–high resistivity. This medium–high resistivity area can be associated with a slowly solidified magma and, therefore, with a hotter part of the geothermal system.  相似文献   

10.
An audio-magnetotelluric investigation in Terceira Island (Azores)   总被引:2,自引:0,他引:2  
Ten audio-magnetotelluric soundings have been carried out along a profile crossing the Serra do Cume caldera in the eastern part of the Terceira Island (Azores). The main objectives of this investigation were to detect geoelectrical features related with tectonic structures and to characterize regional hydrological and hydrothermal aspects mainly those related to geothermal fluid dynamics.Three-dimensional numerical investigation showed that the data acquired at periods shorter than 1 s are not significantly affected by ocean effect. The data was analysed using the Smith's decomposition method in order to investigate possible distortions caused by superficial structures and to estimate a global regional strike. The results suggest that in general the soundings were not distorted. A regional N55°W strike was chosen for the two-dimensional data inversion.The low-resistivity zones (10–30 ohm-m) displayed in the central part of the 2-D geoelectrical model have been interpreted as caused by hydrothermal circulation. The low-resistivity anomalies at the ends of the profile might be attributed to alteration zones with interaction of seawater intrusion. High-resistivity (> 300 ohm-m) values have been related with less permeable zones in the SW of Cinco Picos and Guilherme Moniz caldera walls.  相似文献   

11.
The efficacy of the magnetotelluric and audiomagnetotelluric (MT/AMT) methods for detailing the structure of a hypothetical geological section is investigated by using the singular value decomposition (SVD) technique. The section is representative of southeastern Turkey, which is mostly covered by basalt and is a prime area for oil exploration. One of the geological units, the Germav shale at a depth of 600 m, is a problem layer for electromagnetic surveys because of its very low resistivity (on average 3 Ωm) and highly variable thickness across the area (200–900 m). In the MT frequency range (0.0004–40 Hz) its total conductance—or, since its resistivity is known from resistivity log information, its thickness—is the best resolved model parameter. The total depth to the Germav shale and the resistivity of the Cambrian/Precambrian basement are the marginally resolved parameters. In the AMT frequency range (4–10000 Hz) the resistivity of the surface basalt layer strongly affects the resolution of the other, less important, model parameters which are the total depth to the Germav shale and the total conductance of the Germav shale. The errors in the measurements determine the number of model parameters resolvable, and are also important for interpretation of the geological model parameters to within a desired accuracy. It is shown that statistical evaluation of the MT and/or AMT interpretations by using an SVD factorization of the sensitivity matrix can be helpful to define the importance of some particular stage of the interpretation, and also provides a priori knowledge to plan a proposed survey. Arrangements of MT and AMT observations, together with some Schlumberger resistivity soundings, on a large grid will certainly provide three-dimensional detailed information of the deep geoelectric structure of the area.  相似文献   

12.
In total 77 direct current resistivity soundings were carried out during a geothermal exploration survey of the Genisea, NE Greece, geothermal field. The data revealed a high electrical conductivity zone at the center of the investigated area and suggested that an anomalous heat source lay beneath the study area. This was confirmed by subsequent drilling data. Temperature measurements, from 11 boreholes, were used for the construction of isotherms that correlated very closely with the geoelectric data.  相似文献   

13.
Taal volcano (311?m in altitude) is located in The Philippines (14°N, 121°E) and since 1572 has erupted 33 times, causing more than 2,000 casualties during the most violent eruptions. In March 2010, the shallow structures in areas where present-day surface activity takes place were investigated by DC resistivity surveys. Electrical resistivity tomography (ERT) lines were performed above the two identified hydrothermal areas located on the northern flank of the volcano and in the Main Crater, respectively. Due to rough topography, deep valleys, and dense vegetation, most measurements were collected using a remote method based on a laboratory-made equipment. This allowed retrieval of information down to a depth of 250?m. ERTs results detail the outlines of the two geothermal fields defined by previous self-potential, CO2 soil degassing, ground temperature, and magnetic mapping (Harada et al. Japan Acad Sci 81:261–266, 2005; Zlotnicki et al. Bull Volcanol 71:29–49, 2009a, Phys Chem Earth 34:294–408, 2009b). Hydrothermal fluids originate mainly from inside the northern part of the Main Crater at a depth greater than the bottom of the Crater Lake, and flow upward to the ground surface. Furthermore, water from the Main Crater Lake infiltrates inside the surrounding geological formations. The hydrothermal fluids, outlined by gas releases and high temperatures, cross the crater rim and interact with the northern geothermal field located outside the Main Crater.  相似文献   

14.
This paper presents a tutorial review of electrical and electromagnetic(herein collectively called geoelectromagnetic) methods as applied in the search for natural resources. First, the paper discusses the technical problems and advances in geoelectromagnetic methods in the last decade. A scheme for integrating electrical and electromagnetic depth sounding data is suggested.Then, for natural resources exploration, it focuses on three themes: (1) understandinggeological models of resource targets, their physical properties, and the development of conceptual geoelectromagnetic exploration models, (2) overview of geoelectromagnetic case studies in resourceexploration, and (3) outstanding challenges in exploration. For brevity, model development is restricted to groundwater, geothermal and hydrocarbon resources, metallic ore-bodies (exemplified byvolcanogenic massive sulphides, porphyry coppers, and epithermal and Archaean greenstone belt gold deposits) and diamonds. In the treatment of resource exploration in this paper, the unifying themeis that geochemical processes of weathering and hydrothermal alteration form clayey products that may render natural resource targets directly or indirectly detectable by their resistivity characteristics.Since hydrated clays are an important feature of most resource types and are major causes of low resistivity anomalies in geoelectromagnetic exploration, they may be taken as providing detectable marker horizons or pathfinders and a basis for developing a consistent investigative approachfor natural resources. However, it is recognised that no single resource model or standard approach may be universally applicable. Natural resource systems are inherently 3D and require large numbers of depth soundings at high station densities to image adequately. Thus, developing methodsof increasing the productivity of data acquisition, the development of better 3D software tools and lowering costs are seen as the major challenges facing the use of geoelectromagnetic methods for naturalresource exploration.  相似文献   

15.
An important result of recent years is the normal resistivity profile. It was obtained by interpretation of the combined apparent resistivity curve (magnetotelluric sounding and geomagnetic deep sounding) for the East European platform. This profile has no highly conducting layer and resistivity is greater than 100 ohm-m at asthenospheric depths. It corresponds well with geothermal indications of the absence of partial melting beneath the Precambrian plates. Nearly the same profiles have been obtained for the Canadian shield, and the Siberian and Australian platforms. Investigations carried out in many “hot” regions confirm the existence of a well-developed low-resistivity asthenosphere. Partially molten zones have conductances of about several thousand Siemens in the Eastern Pacific, Iceland and in the North American rift zone. Magnetotelluric soundings show that in many continental areas the lower part of the crust has low resistivity, in the range 10–20 ohm-m. Usually this crustal conductive layer is observed in regions of recent activity. Its total conductivity changes from several hundred to several thousand S. Many investigators propose that the most natural explanation of this conductivity is water solutions.It is necessary to note the distorting role of near-surface inhomogeneities. Local distortions can be eliminated by simple averaging of the experimental data. These average apparent resistivity curves are the starting point for the construction of deep geoelectrical models.  相似文献   

16.
A case history is presented where electromagnetic (EM) methods were applied as a complement to seismic, for structural mapping in basin-and-range-like geology: 366 five-component magnetotelluric (MT) soundings were carried out together with 331 transient soundings (TDEM) along seismic lines. Due to high structural complexity, seismic shows a number of limitations. For the same reasons, MT is highly perturbed and three specific interpretation techniques were comprehensively applied: 1. a classical correction of static effect using TDEM sounding, to determine the high-frequency nondistorted apparent resistivities and thus the corrected tensor; 2. a so-called regional correction based upon the same concept as the static effect, to transform distorted resistivity curves due to the horst/graben situation into plausible 1D curves, through the use of nomograms built for 2D H-polarization situations; 3. a stripping technique which made it possible to map areas where a deep conductive Mesozoic shale was present below carbonates, at a depth of 3 km. After the best MT interpretation was obtained along each line, it was integrated with seismic and with the results from two boreholes. A crude empirical law relating resistivity and acoustic velocity was established and the MT horizons were plotted on the two-way traveltime seismic sections. The final integrated cross-sections obtained are undoubtedly of greater use to the explorationist than the initial seismic sections alone and two wells were accurately predicted.  相似文献   

17.
Norikura Volcano has not been active during the last 10,000 years in spite of the activity of the surrounding volcanic mountains. To study past volcanic activities, geological studies were carried out extensively. However, quite a few geophysical investigations were conducted to contribute to volcanology. Our objective is to detect the present subsurface structure of Norikura Volcano and to define volcanic stratifications. In the vicinity of Norikura Volcano, geothermal fields are still active. Subsurface volcanic rocks in this area have been exposed to geothermal activity and altered. To comprehend volcanic stratifications of Norikura and geothermal activity, we conducted audio frequency magneto-telluric (AMT) surveys around Norikura Volcano. AMT survey is useful in clearly defining the resistivity structure related to volcanic regions. The AMT data were acquired over a frequency range 10 Hz–10 kHz. Decomposition analysis was applied to the tensor impedance data. Subsequently, apparent resistivity and phase data were inverted using a two-dimensional magneto-telluric (MT) inversion and a model of Norikura was derived. The final model manifests that the surface resistors are in agreement with andesite lava or dacite lava. As for the deeper structure, a horizontal conductor is situated above resistive basements. The alteration of the conductor was weak, while basement rocks were strongly altered and/or heated through the thermal activity. The existence of these layers seems to indicate the degree of thermal activity of Norikura Volcano.  相似文献   

18.
地热地球物理勘探新进展   总被引:2,自引:0,他引:2  
地热作为一种清洁能源具有巨大的开发潜力,将在我国的经济发展中起到巨大的作用.在传统的热水型地热开发的基础上,国际上非常重视热干岩(Enhanced Geothermal)型地热的勘探开发.在这两类地热勘查和开发中,地球物理方法具有非常重要的作用.本文从地热系统的目标体岩石的地球物理性质出发,分析岩石的地球物理性质与温度、压力和含水量等影响因素的关系.例如随着温度的升高,岩石会出现去磁、电阻率降低、密度降低、弹性波速度也现明显降低等现象.进而分析地球物理方法应用到具体的地热勘查地质-地球物理异常模型.结合国际上21世纪以后的新方法技术,分析了重磁、电、地震方法在利用由于岩石温度的升高而出现的特殊地球物理现象,并应用于地热勘探.通过国内外实例介绍了各种地球物理勘探方法在地热勘查中成功应用,为进一步提高我国地热勘查水平,提供一些参考.  相似文献   

19.
In the central part of the Bolivian Altiplano, the shallow groundwater presents electrical conductivities ranging from 0·1 to 20 mS/cm. In order to study the origin of this salinity pattern, a good knowledge is required of the geometry of the aquifer at depth. In this study, geophysics has been used to complement the sparse data available from drill holes. One hundred time‐domain electromagnetic (TDEM) soundings were carried out over an area of 1750 km2. About 20 geological logs were available close to some of the TDEM soundings. Three intermediate results were obtained from the combined data: (i) the relationship between the electrical conductivity of the groundwater and the formation resistivity, (ii) geoelectrical cross‐sections and (iii) geoelectrical maps at various depths. The limited data set shows a relationship between resistivity and the nature of the rock. From the cross‐sections, a conductive substratum with a resistivity of less than 1 Ω·m was identified at most of the sites at depths ranging from 50 to 350 m. This substratum could be a clay‐rich formation containing brines. Using derived relationships, maps of the nature of the formation (sandy, intermediate and clayey sediments) were established at depths of 10 and 50 m. Discrimination between sand and clays was impossible where groundwater conductivity is high (>3 mS/cm). In the central part of the area, where the groundwater conductivity is low, sandy sediments are likely to be present from the surface to a depth of more than 200 m. Clayey sediments are more likely to be present in the south‐east and probably constitute a hydraulic barrier to groundwater flow. In conclusion, the study demonstrates the efficiency of the TDEM sounding method to map conductive zones. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
To understand the crustal electric structure of the Puga geothermal field located in the Ladakh Himalayas, wide band (1000 Hz–0.001 Hz) magnetotelluric (MT) study have been carried out in the Puga area. Thirty-five MT sites were occupied with site spacing varying from 0.4 to 1 km. The measurements were carried out along three profiles oriented in east–west direction. After the preliminary analysis, the MT data were subjected to decomposition techniques. The one-dimensional inversion of the effective impedance data and the two-dimensional inversion of the TE (transverse electric) and TM (transverse magnetic) data confirm the presence of low resistive (5–25 Ω m) near surface region of 200–300 m thick in the anomalous geothermal part of the area related to the shallow geothermal reservoir. Additionally, the present study delineated an anomalous conductive zone (resistivity less than 10 Ω m) at a depth of about 2 km which is possibly related to the geothermal source in the area. A highly resistive basement layer separates the surface low resistive region and anomalous conductive part. The estimated minimum temperature at the top of conductive part is about 250 °C. The significance of the deeper conductive zone and its relation to the geothermal anomaly in the area is discussed.  相似文献   