首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Experimental research into the seismic performance of buildings with passive oil dampers has so far been restricted to large-scale testing of frames erected on laboratory shaking tables that ignore the foundation soil below. This simplification of the problem falls short of replicating dynamic soil-structure interaction that would occur in the field. This paper presents the first experimental attempt at utilising high gravity dynamic centrifuge testing to replicate the response of a damped building at a reduced model scale. The paper compares the dynamic response of two similar two-degree-of-freedom model sway frames, one control (bare) frame and one frame equipped with miniature oil dampers, both structures founded on shallow raft foundations in dry dense sand. The miniature oil dampers successfully mitigate floor accelerations, drifts, and storey shear forces in the damped frame with minor modification to the frame stiffness. For strong, near resonance motions, global rocking of the undamped frame associated with physical uplifting of the foundation from the soil surface and subsequent yielding of sand beneath has led to floor acceleration levels, which are comparable to those obtained in the damped building fitted with miniature oil dampers. Assessment of the instrumentation installed on the miniature oil dampers reveals a viscoelastic damper behaviour with a dependency on stroke magnitude and on velocity.  相似文献   

2.
大多数建筑结构由梁、柱、支撑、剪力墙、地基和楼板等主要结构组成。一般而言,楼板对建筑结构的抗震性能可以忽略不计,所以进行建筑结构分析的模型是无楼板的。因此,楼板被刚性隔板代替,以提高分析效率。本文提出的建筑结构抗震分析解析模型考虑了楼板抗弯刚度,该模型采用超级单元、刚性隔板和子结构技术来减少自由度。通过实例分析,验证了该模型在多层建筑结构抗震分析中的有效性和准确性。且此模型能够显著减少计算量,提高分析效率,振动周期和响应时间等分析结果的精度与精化模型的结果非常接近,说明该模型的提出是合理的。  相似文献   

3.
An enhanced reduced model is proposed for elastic earthquake response analysis of a class of mono-symmetric shear building structures with constant eccentricity. The proposed reduction method consists of two parts. The first stage is the construction of a reduced structural model with the degrees of freedom at representative floor levels only. In this stage, an inverse eigenmode-problem formulation is used to guarantee the limited equivalence between the original model and the reduced model. The reduced model is constructed so as to have the same fundamental natural frequency and the same lowest-mode component ratios at the representative floor levels as those of the original model. The second stage is the transformation of earthquake input forces into a set of reduced input forces. This transformation utilizes the static equivalence of lateral-torsional stiffness between these two models and is introduced to enhance the accuracy level of the reduced model. Several examples of a three-dimensional mono-symmetric ten-story shear building model with constant eccentricity are presented to demonstrate the validity and accuracy of the proposed reduction method for earthquake response analysis.  相似文献   

4.
5.
Numerical simulations and parametric studies have been used to investigate the influence of potential poundings of seismically isolated buildings with adjacent structures on the effectiveness of seismic isolation. Poundings are assumed to occur at the isolation level between the seismically isolated building and the surrounding moat wall. After assessing some common force‐based impact models, a variation of the linear viscoelastic impact model is proposed to avoid tensile impact forces during detachment, while enabling the consideration of permanent plastic deformations at the vicinity of the impact. A large number of numerical simulations of seismically isolated buildings with different characteristics have been conducted under six earthquake excitations in order to investigate the influence of various design parameters and conditions on the peak floor accelerations and interstorey deflections during poundings. The numerical simulations demonstrate that poundings may substantially increase floor accelerations, especially t the base floor where impacts occur. Higher modes of vibration are excided during poundings, increasing the interstorey deflections, instead of retaining an almost rigid‐body motion of the superstructure, which is aimed with seismic isolation. Impact stiffness seems to affect significantly the acceleration response at the isolation level, while the displacement response is more insensitive to the variation of the impact stiffness. Finally, the results indicate that providing excessive flexibility at the isolation system to minimize the floor accelerations may lead to a building vulnerable to poundings, if the available seismic gap is limited. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

6.
提出了外剪-内框装配式混合结构体系的概念,介绍了这种新型结构体系的优点及适用范围。以1梯6户的塔式住宅为例,分别建立18层、25层和33层计算模型,研究该结构体系在不同抗震设防烈度情况下的楼层刚度、楼层受剪承载力比、地震作用下的结构剪重比、楼层位移比、楼层位移角等力学及抗震性能性能指标。经分析,外剪-内框装配式混合结构在塔式住宅应用上受力性能合理,结构控制指标符合规范要求,在抗震烈度6度和7度区33层以下住宅可以广泛应用。  相似文献   

7.
A substructure approach is used to estimate the stiffness and damping coefficients of structures from measurement of dynamic responses. The structures are decomposed into smaller subsystems for which state and observation equations are formulated and solved by the method of extended Kalman filter with a weighted global iteration algorithm. Substructural identification methods with and without overlapping members are proposed. In both methods, the convergence of the structural parameters to the optimal values is improved significantly with less computation time as compared to a complete structural approach. Numerical simulation studies are performed for three types of structures, namely a shear building, a plane frame building and a plane truss bridge. The effects of measurement noise and response observations required for identification of system parameters are also investigated.  相似文献   

8.
总结采用梁有效翼缘来考虑楼板及配筋对“强柱弱梁”机制形成的影响的实验和数值仿真研究。基于SAP2000采用三种侧向加载模式对RC框架结构不带楼板、不带楼板考虑梁刚度放大、带楼板的三个模型进行pushover分析,对力与位移的关系曲线、塑性铰的出铰顺序以及顶点位移与层间位移等方面进行探讨。结果表明:三个模型的“强柱弱梁”现象不带楼板的纯框架结构最明显,考虑梁刚度放大的模型次之,带楼板结构最不明显,证明负弯矩承载力和刚度等反映“强柱弱梁”的参数及塑性铰的出现顺序与楼板、板内配筋存在明显的对应关系;楼板及配筋影响框架结构的整体变形性能和塑性耗能能力,是抗震延性机制实现的重要影响因素。在后续的结构设计中,建议考虑实际楼板和钢筋建模进行计算分析。  相似文献   

9.
This paper presents the development of a deformable connection that is used to connect each floor system of the flexible gravity load resisting system (GLRS) with the stiff lateral force resisting system (LFRS) of an earthquake‐resistant building. It is shown that the deformable connection acts as a seismic response modification device, which limits the lateral forces transferred from each floor to the LFRS and allows relative motion between the GLRS and LFRS. In addition, the floor accelerations and the LFRS story shears related to the higher‐mode responses are reduced. The dispersion of peak responses is also significantly reduced. Numerical simulations of the earthquake response of a 12‐story reinforced concrete shear wall example building with deformable connections are used to define an approximate feasible design space for the deformable connection. The responses of the example building model with deformable connections and the example building model with rigid‐elastic connections are compared. Two configurations of the deformable connection are studied. In one configuration, a buckling restrained brace is used as the limited‐strength load‐carrying hysteretic component of the deformable connection, and in the other configuration, a friction device is used. Low damping laminated rubber bearings are used in both configurations to ensure the out‐of‐plane stability of the LFRS and to provide post‐elastic stiffness to the deformable connection. Important experimental results from full‐scale tests of the deformable connections are presented and used to calibrate numerical models of the connections. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
This paper focuses on slab vibration and a horizontal‐vertical coupling effect observed in a full‐scale 5‐story moment frame test bed building in 2 configurations: isolated with a hybrid combination of lead‐rubber bearings and cross‐linear (rolling) bearings, and fixed at the base. Median peak slab vibrations were amplified—relative to the peak vertical shake table accelerations—by factors ranging from 2 at the second floor to 7 at the roof, and horizontal floor accelerations were significantly amplified during 3D (combined horizontal and vertical) motions compared with 2D (horizontal only) motions of comparable input intensity. The experimentally observed slab accelerations and the horizontal‐vertical coupling effect were simulated through a 3D model of the specimen using standard software and modeling assumptions. The floor system was modeled with frame elements for beams/girders and shell elements for floor slabs; the insertion point method with end joint offsets was used to represent the floor system composite behavior, and floor mass was finely distributed through element discretization. The coupling behavior was partially attributed to the asymmetry of the building that was intensified by asymmetrically configured supplemental mass at the roof. Horizontal‐vertical coupled modes were identified through modal analysis and verified with evaluation of floor spectral peaks.  相似文献   

11.
Floor isolation system (FIS) achieving very small floor accelerations has been used to ensure human comfortability or protect important equipments in buildings. Tuned mass damper (TMD) with large mass ratios has been demonstrated to be robust with respect to the changes in structural properties. This paper presents the concept of a TMD floor vibration control system, which takes advantages of both the FIS and TMD. Such a system is called ‘TMD floor system’ herein. The TMD floor system (TMDFS) in which building floors serve as TMDs can achieve large mass ratio without additional masses. Furthermore, multiple TMD floors installed in a building can control multimode vibrations. Then, an optimal design process, where the objective function is set as the maximum magnitude of the frequency response functions of inter‐storey drifts, is proposed to determine the TMD floor parameters. Additionally, the multimode approach is applied to determine the optimal locations of TMD floors if not all of the floors in a building can serve as TMDs. In addition to the numerical simulations, a scaled model shaking table experiment is also conducted. Both the numerical and experimental results show that the absolute accelerations of the TMD floors are smaller than those of the main structural storeys, which indicates the TMDFS maintains the merit of FIS while greatly reducing seismic responses of main structures. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Shear building representations of seismically isolated buildings   总被引:2,自引:0,他引:2  
Seismic isolation, with its capability of reducing floor accelerations and interstory drifts simultaneously, is recognized as an earthquake resistant design method that protects contents of a building along with the building itself. In research studies, superstructures of seismically isolated buildings are commonly modeled as idealized shear buildings. Shear building representation corresponds to an idealized structure where the beams are infinitely stiff in flexure and axially inextensible; columns are axially inextensible; and rigid floors are supported on these columns. Although it is more convenient to model and analyze a shear building, such an idealization may influence the seismic responses of seismically isolated buildings. This study presents a comparison of the seismic performances of seismically isolated buildings with superstructures modeled as shear buildings to those with full three dimensional superstructures. Both linear and nonlinear base isolation systems with different isolation periods and superstructures with different number of stories are considered.  相似文献   

13.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
Moat wall pounding occurs when a base-isolated building displaces beyond the provided clearance and collides with the surrounding retaining wall, inducing very high floor accelerations and interstory drifts. Previous studies on moat wall pounding typically employ simplified models of the superstructure, with a uniaxial contact spring used to model the entire moat wall. Consequently, researchers have developed sophisticated contact models to estimate the normal-direction contact force that is generated during seismic pounding. This study examines how the choice in contact model affects the seismic response of a base-isolated building subjected to impact-inducing ground excitation. Five widely used state-of-the-art contact models are summarized and implemented into an experimentally-calibrated numerical model of a base-isolated moment frame. Results of nonlinear dynamic time history analyses are shown in detail for one ground motion, followed by a larger parametric study across 28 near-fault ground motions. This work shows that peak impact force and base acceleration are moderately sensitive to the choice in contact model, while upper floor accelerations and interstory drifts are practically not affected.  相似文献   

15.
Shear‐type buildings with Maxwell model‐based brace–damper systems are studied in this paper with a primary emphasis on the effects of brace stiffness. A single‐story building with a viscous damper installed on top of a Chevron‐brace is first investigated. Closed‐form solutions are derived for the simple structure, relating the brace stiffness and damper coefficient to the targeted reduction in response displacement or acceleration. For a given brace stiffness, the solution is minimized to give a set of formulae that will allow the optimal damper coefficient to be determined, assuring the desired performance. The model is subsequently extended to multistory buildings with viscous dampers installed on top of Chevron‐braces. For a targeted reduction in the mean square of the interstory drift, floor acceleration or base shear force, the minimum brace stiffness and optimal damper coefficients are obtained through an iterative procedure. The response reduction, which signifies the improved performance, is achieved by a combination of brace stiffness and viscous damper coefficients, unlike conventional approaches where damper coefficients are typically optimized independent of brace stiffnesses. Characteristics of multi‐degree‐of‐freedom systems are studied using a 2‐story and a 10‐story buildings where the effects of brace stiffness on the overall performance of the building can be quantified. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
A new method of stiffness‐damping simultaneous identification of building structures is proposed using limited earthquake records. It is shown that when horizontal accelerations are recorded at the floors just above and below a specific storey in a shear building model, the storey stiffness and the damping ratio can be identified uniquely. The viscous damping coefficient and the linear hysteretic damping ratio can also be identified simultaneously in a numerical model structure. The accuracy of the present identification method is investigated through the actual limited earthquake records in a base‐isolated building. It is further shown that an advanced identification technique for mechanical properties of a Maxwell‐type model can be developed by combining the present method with a perturbation technique. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

17.
为研究钢筋砼摩擦耗能支撑框架结构的动力反应性能 ,对其中的摩擦耗能器单元和框架杆单元的单元刚度和力学模型做了分析。钢筋砼摩擦耗能支撑单元由支撑杆单元和钢板—橡胶摩擦耗能器单元组成 ,支撑单元可取空间杆单元 ,摩擦耗能器单元为平面应力矩形单元。摩擦耗能器单元的剪切恢复力曲线为理想的弹塑性曲线 ,根据耗能器单元的力学模型 ,可确定其在每一时刻的刚度 ;框架结构空间杆单元的恢复力模型采用双线型模型 ,根据杆单元的力学模型 ,可确定其在每一时刻的刚度。并利用所编制的程序对十层单榀两跨空间普通框架和摩擦耗能支撑框架在地震作用下进行了弹塑性反应时程分析 ,结果表明耗能支撑框架的顶层最大位移明显小于普通框架  相似文献   

18.
杨建华  叶郁 《地震工程学报》2019,41(5):1141-1146,1176
为实现多层砖房底部两层框架结构的加固,需要研究其抗震变形性能。以某底部两层框架、上部四层砖房建筑为对象,通过STRAND7有限元软件构建有限元计算模型,考虑水平荷载与垂直荷载,深入分析多层砖房底部两层框架抗震变形性能。仿真结果表明,建筑结构振型受结构横向楼板刚度的影响较显著,不同振型的频率变化中,X向1阶频率与Y向2阶频率变化最快,楼板平面内弯曲频率变化最慢;整体结构在X向与Y向分别呈现线性剪切变形和弯剪变形,Y向上由于填充墙发挥抗震墙功能,底部两层框架变形较小;在7度多遇地震影响下,底部两层结构中第二层楼板变形较第一层严重,多层砖房底部两层框架建筑结构处于弹性工作状态。  相似文献   

19.
Analytical models prepared from field drawings do not generally provide results that match with experimental results.The error may be due to uncertainties in the property of materials,size of members and errors in the modelling process.It is important to improve analytical models using experimentally obtained data.For the past several years,data obtained from ambient vibration testing have been successfully used in many cases to update and match dynamic behaviors of analytical models with real structures.This paper presents a comparison between artificial neural network(ANN) and eigensensitivity based model updating of an existing multi-story building.A simple spring-mass analytical model,developed from the structural drawings of the building,is considered and the corresponding spring stiffness and lumped mass of all floors are chosen as updating parameters.The advantages and disadvantages of these updating methods are discussed.The advantage is that both methods ensure a physically meaningful model which canbe further employed in determining structural response and health monitoring.  相似文献   

20.
This paper verifies the feasibility of the proposed system identification methods by utilizing shaking table tests of a full‐scale four‐story steel building at E‐Defense in Japan. The natural frequencies, damping ratios and modal shapes are evaluated by single‐input‐four‐output ARX models. These modal parameters are prepared to identify the mass, damping and stiffness matrices when the objective structure is modelled as a four degrees of freedom (4DOF) linear shear building in each horizontal direction. The nonlinearity in stiffness is expressed as a Bouc–Wen hysteretic system when it is modelled as a 4DOF nonlinear shear building. The identified hysteretic curves of all stories are compared to the corresponding experimental results. The simple damage detection is implemented using single‐input‐single‐output ARX models, which require only two measurements in each horizontal direction. The modal parameters are equivalent‐linearly evaluated by the recursive Least Squares Method with a forgetting factor. When the structure is damaged, its natural frequencies decrease, and the corresponding damping ratios increase. The fluctuation of the identified modal properties is the indirect information for damage detection of the structure. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   