首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study is to investigate the effect of retrofitting dynamic characteristics of a damaged laboratory arch dam model, subsequently repaired with high-strength structural mortar and strengthened with composite carbon fiber reinforced polymer. This study constructed in laboratory conditions is a prototype arch dam–reservoir–foundation model. Five test cases of ambient vibration on the arch dam model illustrate the changes in dynamic characteristics: natural frequency, mode shape, and damping ratio, before and after retrofitting. The ambient vibration tests collected data from the dam body during vibrations by natural excitations which provided small impacts and response signals from sensitivity accelerometers placed at crest points. Enhanced Frequency Domain Decomposition Method in the frequency domain extracts the experimental dynamic characteristics. At the end of the study, experimentally identified dynamic characteristics obtained from all test cases have been compared with each other. Apparently, after the retrofitting, the natural frequencies of the dam body increased considerably, demonstrating that the retrofitting, including repairing and strengthening is very effective on the flashback of initial dynamic characteristics.  相似文献   

2.
武璠  程琳  杨杰  郑东健 《地震工程学报》2021,43(6):1460-1471
利用混凝土拱坝地震记录识别的模态参数,可以揭示结构在地震过程中实际动力特性的变化情况,为结构地震反应分析和震后损伤评估提供重要信息。首先对模态识别常用方法的基本原理进行介绍;然后利用龙羊峡拱坝两次地震观测数据,采用"输入—输出"型和"仅考虑输出"型两类方法对大坝模态参数进行识别;最后将获得的模态识别结果与工程经验值和其他学者的研究成果进行对比,以分析评价识别结果的合理性。相关研究成果可为基于地震记录的混凝土拱坝模态参数识别的工程应用提供经验借鉴。  相似文献   

3.
In an effort to study the dynamic characteristics of an arch dam system from the vibration test results, a systematic method of frequency-domain system identification is developed. The governing equations for system identification are based on a non-classical modal superposition method. The non-classical model is shown to be derivable from a general matrix formulation of the dam system. The conventional classical modal formulation becomes a special case of the general non-classical formulation. The modal parameters of the non-classical and the classical formulation are to be identified. The system identification method includes a single-mode sweep procedure for initial parameter estimation and a progressive multiple-mode parameter identification scheme that contains an information criterion for the determination of the optimal number of modes to be included in the identification process. The method is applicable to data measured at more than one point on the dam and to data that include both the amplitude response and the phase response. The method is applied to the vibration test data of two dams. Based on the results of these applications, the adequacy of the classical model and the non-classical model is compared and the effect of the phase data on the parameter determination is discussed.  相似文献   

4.
An extensive programme of full-scale ambient vibration tests has been conducted to measure the dynamic response of a 542 m (centre span of 274 m) cable-stayed bridge—the Quincy Bayview Bridge in Illinois. A microcomputer-based system was used to collect and analyse the ambient vibration data. A total of 25 modal frequencies and associated mode shapes were identified for the deck structure within the frequency range of 0–2 Hz. Also, estimations were made for damping ratios. The experimental data clearly indicated the occurrence of many closely spaced modal frequencies and spatially complicated mode shapes. Most tower modes were found to be associated with the deck modes, implying a considerable interaction between the deck and tower structure. No detectable levels of motion were evident at the foundation support of the pier. The results of the ambient vibration survey were compared to modal frequencies and mode shapes computed using a three-dimensional finite element model of the bridge. For most modes, the analytic and experimental modal frequencies and mode shapes compare quite well, especially for the vertical modes. Based on the findings of this study, a linear elastic finite element model appears to be capable of capturing much of the complex dynamic behaviour of the bridge with very good accuracy, when compared to the low-level dynamic responses induced by ambient wind and traffic excitations.  相似文献   

5.
Dynamic characteristics of structures — viz. natural frequencies, damping ratios, and mode shapes — are central to earthquake‐resistant design. These values identified from field measurements are useful for model validation and health‐monitoring. Most system identification methods require input excitations motions to be measured and the structural response; however, the true input motions are seldom recordable. For example, when soil–structure interaction effects are non‐negligible, neither the free‐field motions nor the recorded responses of the foundations may be assumed as ‘input’. Even in the absence of soil–structure interaction, in many instances, the foundation responses are not recorded (or are recorded with a low signal‐to‐noise ratio). Unfortunately, existing output‐only methods are limited to free vibration data, or weak stationary ambient excitations. However, it is well‐known that the dynamic characteristics of most civil structures are amplitude‐dependent; thus, parameters identified from low‐amplitude responses do not match well with those from strong excitations, which arguably are more pertinent to seismic design. In this study, we present a new identification method through which a structure's dynamic characteristics can be extracted using only seismic response (output) signals. In this method, first, the response signals’ spatial time‐frequency distributions are used for blindly identifying the classical mode shapes and the modal coordinate signals. Second, cross‐relations among the modal coordinates are employed to determine the system's natural frequencies and damping ratios on the premise of linear behavior for the system. We use simulated (but realistic) data to verify the method, and also apply it to a real‐life data set to demonstrate its utility. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
This paper describes ambient vibration based seismic evaluation procedure of an isolated highway bridge. The procedure includes finite element modeling, ambient vibration testing, finite element model updating and time history analysis. Gülburnu Highway Bridge located on the Giresun–Espiye state highway is selected as a case study. Three dimensional finite element model of the bridge is created by SAP2000 software to determine the dynamic characteristics analytically. Since input force is not measured, Operational Modal Analysis is applied to identify dynamic characteristics. Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification methods are used to obtain experimental dynamic characteristics. Analytical and experimental dynamic characteristic are compared with each other and finite element model of the bridge is updated by changing of material properties to reduce the differences between the results. Analytical model of the bridge after model updating is analyzed using 1992 Erzincan earthquake record to determine the seismic behavior. EW, NS and UP components of the ground motion are applied to the bridge at the longitudinal, transverse and vertical directions, respectively. It is demonstrated that the ambient vibration measurements are enough to identify the most significant modes of highway bridges. Maximum differences between the natural frequencies are reduced averagely from 9% to 2% by model updating. It is seen from the earthquake analyses that friction pendulum isolators are very effective in reducing the displacements and internal forces.  相似文献   

7.
The dynamic characteristics of two representative R/C bridges on Egnatia Odos motorway in Greece are estimated based on low amplitude ambient and earthquake-induced vibrations. The present work outlines the instrumentation details, algorithms for computing modal characteristics (modal frequencies, damping ratios and modeshapes), modal-based finite element model (FEM) updating methods for estimating structural parameters, and numerical results for the modal and structural dynamic characteristics of the two bridges based on ambient and earthquake induced vibrations. Transverse, bending and longitudinal modes are reliably identified and stiffness-related properties of the piers, deck and elastomeric bearings of the FEMs of the two bridges are estimated. Results provide qualitative and quantitative information on the dynamic behavior of the bridge systems and their components under low-amplitude vibrations. Modeling assumptions are discussed based on the differences in the characteristics identified from ambient and earthquake vibration measurements. The sources of the differences observed between the identified modal and structural characteristics of the bridges and those predicted by FEMs used for design are investigated and properly justified.  相似文献   

8.
This work presents a unified procedure for determining the natural frequencies, modal damping ratios and modal shapes of a structure from its ambient vibration, free vibration and earthquake response data. To evaluate the coefficient matrices of a state‐space model, the proposed procedure applies a subspace approach cooperating with an instrumental variable concept. The dynamic characteristics of a structure are determined from the coefficient matrices. The feasibility of the procedure is demonstrated through processing an in situ ambient vibration measurement of a five‐storey steel frame, an impulse response measurement of a three‐span continuous bridge, and simulated earthquake responses of five‐storey steel frames from shaking table tests. The excellent agreement of the results obtained herein with those published previously confirms the feasibility of the present procedure. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
To investigate the seismic liquefaction performance of earth dams under earthquake loading, we present a new methodology for evaluating the seismic response of earth dams based on a performance‐based approach and a stochastic vibration method. This study assesses an earthfill dam located in a high‐intensity seismic region of eastern China. The seismic design levels and corresponding performance indexes are selected according to performance‐based criteria and dam seismic codes. Then, nonlinear constitutive models are used to derive an array of deterministic seismic responses of the earth dam by dynamic time series analysis based on a finite element model. Based on these responses, the stochastic seismic responses and dynamic reliability of the earth dam are obtained using the probability density evolution method. Finally, the seismic performance of the earth dam is assessed by the performance‐based and reliability criteria. Our results demonstrate the accuracy of the seismic response analysis of earth dams using the random vibration method. This new method of dynamic performance analysis of earth dams demonstrates that performance‐based criteria and reliability evaluation can provide more objective indices for decision‐making rather than using deterministic seismic acceleration time series as is the current normal practice. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
Strong-motion accelerograms obtained on the San Juan Bautista 156/101 Separation Bridge during the 6 August 1979 Coyote Lake, California, earthquake are used to examine the response of this multiple-span bridge to moderate levels of earthquake loading. Although the bridge was not damaged, the records are of significant engineering interest as they are the first to be recorded on a highway bridge structure in North America. A technique of system identification is used to determine optimal modal parameters for linear models which can closely replicate the observed time-domain seismic response of the bridge. Time variations in frequency and damping in the horizontal response are identified using a moving-window analysis. A three-dimensional finite element model is developed to study the bridge response in detail. The first two horizontal modal frequencies computed from this model are in excellent agreement with information obtained during the system identification analysis provided the finite element model's expansion joints are locked, preventing relative translational motions from occurring across the joints. Locking is confirmed by the observed seismic deformations of the structure in the fundamental mode. Fundamental vertical frequencies of the individual spans, predicted by the finite element model, are in very good agreement with ambient vibration test data.  相似文献   

11.
For almost a decade, a 66‐storey, 280m tall building in Singapore has been instrumented to monitor its dynamic responses to wind and seismic excitations. The dynamic characteristics of the tall building have been investigated via both the finite element method and the experimental modal analysis. The properties of the finite element model have been shown to correlate well with those derived from the data recorded during the ambient vibration tests. During the study period, 21 sets of earthquake ground motions have been recorded at the building site. The basement motions may be divided into three categories based on their predominant frequency components with respect to the building's fundamental frequency. The calibrated three‐dimensional finite element model is employed to simulate the seismic response of the tall building. Correlation analysis of the time histories between the recorded data and the simulated results has been carried out. The correlation analysis results show that the simulated dynamic response time histories match well with those of the recorded dynamic responses at the roof level. The results also show that the simulated maximum response at the roof level is close to the peak response recorded during the earthquakes. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
This paper addresses the issue of structural system identification using earthquake‐induced structural response. The proposed methodology is based on the subspace identification algorithm to perform identification of structural dynamic characteristics using input–output seismic response data. Incorporated with subspace identification algorithm, a scheme to remove spurious modes is also used to identify real system poles. The efficiency of the proposed method is shown by the analysis of all measurement data from all measurement directly. The recorded seismic response data of three structures (one 7‐story RC building, one midisolation building, and one isolated bridge), under Taiwan Strong Motion Instrumentation Program, are analyzed during the past 15 years. The results present the variation of the identified fundamental modal frequencies and damping ratios from all the recorded seismic events that these three structures had encountered during their service life. Seismic assessment of the structures from the identified system dynamic characteristics during the period of their service is discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents the application of system identification (SI) to long‐span cable‐supported bridges using seismic records. The SI method is based on the System Realization using Information Matrix (SRIM) that utilizes correlations between base motions and bridge accelerations to identify coefficient matrices of a state‐space model. Numerical simulations using a benchmark cable‐stayed bridge demonstrate the advantages of this method in dealing with multiple‐input multiple‐output (MIMO) data from relatively short seismic records. Important issues related to the effects of sensor arrangement, measurement noise, input inclusion, and the types of input with respect to identification results are also investigated. The method is applied to identify modal parameters of the Yokohama Bay Bridge, Rainbow Bridge, and Tsurumi Fairway Bridge using the records from the 2004 Chuetsu‐Niigata earthquake. Comparison of modal parameters with the results of ambient vibration tests, forced vibration tests, and analytical models are presented together with discussions regarding the effects of earthquake excitation amplitude on global and local structural modes. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

14.
In countries with a moderate seismic hazard, the classical methods developed for strong motion prone countries to estimate the seismic behaviour and subsequent vulnerability of existing buildings are often inadequate and not financially realistic. The main goals of this paper are to show how the modal analysis can contribute to the understanding of the seismic building response and the good relevancy of a modal model based on ambient vibrations for estimating the structural deformation under weak earthquakes. We describe the application of an enhanced modal analysis technique (frequency domain decomposition) to process ambient vibration recordings taken at the Grenoble City Hall building (France). The frequencies of ambient vibrations are compared with those of weak earthquakes recorded by the French permanent accelerometric network (RAP) that was installed to monitor the building. The frequency variations of the building under weak earthquakes are shown to be less (∼2%) and therefore ambient vibration frequencies are relevant over the elastic domain of the building. The modal parameters extracted from ambient vibrations are then used to determine the 1D lumped‐mass model in order to reproduce the inter‐storey drift under weak earthquakes and to fix a 3D numerical model that could be used for strong earthquakes. The correlation coefficients between data and synthetic motion are close to 80 and 90% in horizontal directions, for the 1D and 3D modelling, respectively. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
Two approximate methods for decomposing complicated inelastic dynamic responses of wall buildings into simple modal responses are presented. Both methods are based on the equivalent linear concept, where a non‐linear structure is represented by a set of equivalent linear models. One linear model is used for representing only one vibration mode of the non‐linear structure, and its equivalent linear parameters are identified from the inelastic response time histories by using a numerical optimizer. Several theoretical relations essential for the modal decomposition are derived under the framework of complex modal analysis. Various numerical examinations have been carried out to check the validity of the proposed modal decomposition methods, and the results are quite satisfactory in all cases. Fluctuating bending moment and shear at any location along the wall height contributed by each individual vibration mode can be obtained. Modal contributions to shear and flexural strength demands, as well as the corresponding modal properties, under various seismic loading conditions can also be identified and examined in detail. Furthermore, the effects of higher vibration modes on seismic demands of wall buildings are investigated by using the modal decomposition methods. Several new insights into the complicated inelastic dynamics of multi‐story wall buildings are presented. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

16.
During the past strong ground motions, chimneys constructed according to international standards are representative of similar structures at industrial areas throughout the world, including those collapsed or moderately damaged in earthquake-prone regions. This is due to the specialty of structural characteristics and the special loads acting on the structure such as earthquakes, wind and differences in the level of temperature, etc. In this context, the researchers and designers should focus on the dynamic behavior of chimneys especially under high temperature and seismic effects. For this purpose, the main focus of this study is to evaluate the dynamic response of a chimney under the above-mentioned effects considering soil-structure interaction (SSI). A 52 m steel chimney in Yeşilyurt township of Samsun City in Turkey was studied. The in-situ model testing and numerical models were compared. Before the commissioning of the chimney, a series of tests was realized to define its dynamic characteristics in case of no-heat and after the fabric got to work, the same tests were repeated for the same sensor locations to understand the heat effect on the dynamic response of the chimney. The ambient vibration tests are proven to be fast and practical procedures to identify the dynamic characteristics of those structures. The dynamic testing of the towers promises a widespread use, as the identification of seismic vulnerability of such structures becomes increasingly important. The data presented in this study are considered to be useful for the researchers and engineers, for whom the temperature and SSI effects on steel chimneys are a concern. Using the modal analysis techniques, presented finite element simulation for the soil/pile foundation-chimney interaction system is verified. The results of modal analyses using numerical solutions are shown to have acceptable accuracy compared with results obtained by in-situ test. The present study also aims to provide designers with material examples about the influence of these on the seismic performance of steel chimneys by means of reflecting the changes in the dynamic behavior.  相似文献   

17.
随机子空间方法在桥塔模态参数识别中的应用   总被引:3,自引:0,他引:3  
基于环境振动的结构模态参数识别方法正逐渐成为国内外研究的一大热点。环境振动方法就是仅仅利用结构测试的输出信号进行结构的模态参数识别,随机子空间方法就是其中的一种。随机子空间法是近年来发展起来的一种线性系统辩识方法,可以有效地从环境激励的结构响应中获取模态参数。它属于时域的方法,该方法不需要进行FFT变换,它不仅可以识别结构的频率,而且可以识别结构的阻尼和振型。文章首先介绍了随机子空间的理论,然后用该方法对正在施工中的南京长江三桥的南塔进行模态参数识别,通过与其他方法的识别结果进行比较,证明随机子空间方法不失为一种有效的模态参数识别方法。  相似文献   

18.
Ambient vibration tests were conducted on a base-isolated apartment building in Takamatsu, Japan, to determine the mode shapes and the associated natural frequencies and damping ratios at very low levels of excitation. The latest developments in signal analysis for modal decomposition are used to analyze the ambient response data. A finite element model of the building and isolators was calibrated and refined using the experimental results from the ambient vibration tests. This model was then used to simulate the recorded response of the building under excitation from a small earthquake. The finite element model, calibrated by ambient vibration data and the low level of earthquake shaking, provides the starting point for modelling the non-linear response of the building when subjected to strong shaking.  相似文献   

19.
提出了基于经验模式分解(EMD)的环境激励结构模态参数随机子空间识别(SSI)方法。该方法用设置间断频率的EMD将结构环境振动响应原始信号分解成若干个基本模式分量(IMF),使每一个基本模式分量仅为结构的某一阶固有模态,进而用随机子空间方法进行模态参数识别。实桥环境振动实验分析结果表明,该方法能有效地避免结构各阶模态之间的相互影响,能够更清晰方便地得到结构的模态参数。  相似文献   

20.
This paper presents a new identification technique for the extraction of modal parameters of structural systems subjected to base excitation. The technique uses output‐only measurements of the structural response. A combined subspace‐maximum likelihood algorithm is developed and applied to a three‐degree‐of‐freedom simulation model. Five ensembles of synthetically generated input signals, representing varying input characteristics, are employed in Monte Carlo simulations to illustrate the applicability of the method. The technique is able to circumvent some of the difficulties arising from short data sets by employing the Expectation Maximization (EM) algorithm to refine the subspace state estimates. This approach is motivated by successful application by previous authors on speech signals. Results indicate that, for certain system characteristics, more accurate pole estimates can be identified using the combined subspace‐EM formulation. In general, the damping ratios of the system are difficult to identify accurately due to limitations on data set length. The applicability of the technique to structural vibration signals is illustrated through the identification of seismic response data from the Vincent Thomas Bridge. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号