首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 140 毫秒
1.
中国气象局雷电野外科学试验基地开展的人工触发闪电试验是研究闪电电磁辐射效应的有效手段,利用架设在试验场地周边的多套磁场天线所获取的高灵敏度磁场数据,针对初始连续电流阶段的中低频磁场特征开展研究。得益于磁场天线带宽的拓展,首次解析出了相对平静期内的磁场脉冲,单个脉冲的平均宽度约为1 μs,平均脉冲间隔约为14 μs,对应了该阶段中上行先导的小尺度击穿发展形式;在近、远距离磁场测量中均观测到了与先导通道头部击穿放电相关的爆发式磁场脉冲,其平均脉冲间隔(约为24.5 μs)明显大于平静期脉冲的统计值,而且在爆发式脉冲期间通道底部电流逐步增大到几十至上百安培,表明此时电场条件更加有利于上行先导的发展;此外,高灵敏磁场天线能够直观地呈现出初始连续电流脉冲(initial continuous current pulse,ICCP)的电荷传输过程,且ICCP期间观测到的规则磁场脉冲的脉冲间隔比其他类型的磁场脉冲小一个量级,可能体现了正极性击穿和负极性击穿的特征差异。  相似文献   

2.
基于自主研发的闪电连续干涉仪,对2019年6月11日在中国气象局雷电野外科学试验基地广州从化人工引雷试验场成功触发的一次多回击闪电放电全过程进行观测,结合通道底部电流数据和电场变化数据,共同揭示触发闪电全放电过程:连续干涉仪能够定位到最小为8 A的不连续的先驱电流脉冲辐射信号,初始先驱电流脉冲(IPCP)的平均转移电荷量约为先驱电流脉冲(PCP)的2倍;上行正先导连续发展后为初始连续电流(ICC)过程,最初正流光通道以105 m·s-1量级的速度继续发展延伸,之后出现反冲先导放电;在ICC阶段出现的经典M分量,可由向前的106 m·s-1量级速度的正流光(先导)产生,也可由已有通道头部产生的反冲先导产生,且整个M分量过程中,多个反冲先导维持了放电过程的持续;之后的回击间过程以反冲先导为主要放电形式,回击电流脉冲之前存在多次反冲先导过程,但多数未发展到接地通道,只处于企图先导阶段,直至成功的先导回击产生;而前两次回击具有超短的时间间隔,约为4.5 ms,这是由于两次回击前的先导来源于云内不同分支的反冲先导过程。  相似文献   

3.
一次多分叉多接地的空中触发闪电过程   总被引:3,自引:3,他引:0       下载免费PDF全文
该文分析了2007年广州从化人工引雷试验中,6月30日一次空中触发负极性闪电的光学和电学观测资料,结果表明:此次空中触发闪电的上行正先导和下行负先导分别出现了多个分叉。上行正先导早于下行负先导4.93 ms始发,上行正先导初始阶段的二维平均速度为104m/s量级,后增加到105m/s量级。下行负先导经历了3次分叉后分为4个分支接地,其中有两个接地分支一直持续发光到闪电放电结束,观测到下行负先导的二维平均速度为1.69×105m/s。小回击之后上行正先导也出现了多个分支,高速摄像和宽带干涉仪对这些分支的观测结果基本一致。小回击之后,初始长连续电流过程的持续时间为178.6 ms。  相似文献   

4.
人工触发闪电放电过程分析:I.先导放电过程   总被引:4,自引:3,他引:1  
言穆弘 《高原气象》1998,17(3):271-279
利用人工触发闪电电场,电流和闪电通道亮度高速摄像观测资料,分析了第一次回击前衔导过程的放电特性,结果指出,对于空中触发,先导传输具有“双向”特征,由于下行先导发展,先导通道电流分布具有不均匀性,连接导线汽化都发生在上行先导阶段。人工闪电第一次回击虽然与自然闪电继后回击特性十分相似,但两者放电特征仍有差别,前者具有曾长的连续电流过程。  相似文献   

5.
为实现对地闪过程中多上行先导现象的模拟,在已有三维随机放电参数化方案基础上,植入多先导始发与发展模块以建立高建筑群多上行先导模型,利用电场并行计算技术提高模拟效率。将新模型应用于实际地闪模拟并就统计数据与先导形态特征同观测数据进行对比。结果表明:上行未连接先导长度为12~709 m,起始高度为360~600 m,距连接点水平距离为255~1026 m,距下行先导最近分支的距离为326~589 m,与观测统计结果具有较高的一致性;形态上再现了实际地闪个例F1215中上行未连接先导始发时间早,通道笔直的特点,也能够模拟下行先导与单上行先导头部、单上行先导侧面、多上行先导中连接先导头部、多上行先导中连接先导侧面4种已有观测记录的连接情况,为后续研究提供基础模型。分析模拟结果初步得出结论:最高的广州塔能够对附近一定范围建筑起保护作用且能吸引较远处的下行先导分支;多先导的始发与最后一跳的连接受地面高建筑物群分布、高度以及下行先导位置综合影响。  相似文献   

6.
利用低频磁场天线遥感测量人工引雷中的初始连续电流   总被引:2,自引:2,他引:0  
2014年夏季的山东人工引雷实验中,我们利用高灵敏度宽频段磁场天线在距引雷点78 m的距离上开展了对人工引雷初始连续电流过程的遥感测量。通过分析实验期间5次人工引雷的综合观测数据,发现磁场遥感方法对人工引雷中特有的初始连续电流有很好的反演效果。通过对78 m距离上获得的磁场测量信号进行积分处理,能够有效地抑制测量过程中白噪声的影响,从而反演得到初始连续电流的低噪声时变波形。该方法为获取空中引雷实验中的初始连续电流波形提供了一种解决方案,同时也可用于反演近距离自然闪电中地闪回击中的长连续电流的时变波形。  相似文献   

7.
一次人工引发闪电初始电流及其电磁场变化特征   总被引:1,自引:0,他引:1  
研制了近距离闪电磁场变化测量系统,并在2005年夏季山东滨州的人工引发闪电试验中,获得了闪电电流和距闪电通道60 m处的1μs时间分辨率的电磁场变化同步观测资料。本文详细分析了一次人工引发闪电放电初始阶段的电流及近距离电磁场。本次引发闪电中火箭拖带的导线底端通过一段5 m左右的尼龙线与引流杆相接,这段空气间隙击穿放电所产生的电流为720A,对应的60 m处电场和磁感应强度变化分别为0.38 kV/m和11.26μT。对同步资料的进一步分析表明,人工引发闪电上行正先导电流脉冲时间间隔为18.0~25.0μs,平均峰值电流为23.0A,变化范围为16.9~41.0A;单个先导过程转移电荷量的平均值为84.3μC,变化范围为57.8~141.0μC。60 m处先导电场峰值和磁感应强度峰值的平均值分别为16.7 V/m和0.3μT,变化范围分别为8.7~28.2V/m和0.116~0.544μT。先导电流峰值Ip(A)与其产生的磁感应强度峰值B(μT)之间满足Ip=61.9B 2.56。  相似文献   

8.
山东人工引发雷电综合观测实验及回击电流特征   总被引:3,自引:2,他引:1  
山东人工引发雷电实验 (SHATLE) 自2005年开始, 六年来共成功引发负极性雷电22次, 包含大电流回击过程88次, 实验获取了包括雷电放电通道底部电流、近距离电磁场、 高速摄像等在内的高质量同步观测资料。对36次实测回击电流的统计分析表明, 回击峰值电流的几何平均值为12.1 kA, 最大值为41.6 kA, 最小值为4.4 kA。回击电流波形的半峰值宽度范围在1~68 μs之间, 电流10%~90%峰值的上升时间几何平均值为1.9 μs, 中和电荷量为0.86 C, 作用积分(action integral, 或称比能量) 为2.6 ×103A2?s。人工触发闪电峰值电流约16.5 kA的回击在30 m处产生的电场变化可达56.0 kV/m, 60 m处的磁场几何平均值为52 μT。一些强烈的M分量可以具有与回击相当的电流峰值和中和电荷量。人工引雷初始阶段上行正先导的发展速度约为0.96×105 m/s。  相似文献   

9.
伴随超强VHF辐射的闪电双极性窄脉冲初步观测   总被引:5,自引:1,他引:5  
闪电过程中一类双极性脉冲辐射伴随的超过常规闪电一个数量级的VHF辐射是卫星观测的穿越电离层的脉冲对(TIPPs)的来源。文中给出了在中国上海地区观测到的该类放电事件产生的78例双极性窄脉冲。典型的双极性窄脉冲上升时间约1.2μs,初始峰宽度约2—3μs、半宽约1μs,整个脉冲持续时间约15μs,脉冲幅度与地闪首次回击幅度相当,过冲幅度约为初始峰幅度的1/3。这类脉冲波形特征与普通闪电双极性脉冲波形特征差异明显。根据空间双极性脉冲被电离层以及地面-电离层反射的时间延迟并假定电离层高度为85 km,估算了这些双极性窄脉冲发生高度。11例负极性脉冲(对应上面负电荷区对下部正电荷区之间的放电)中有10例脉冲发生高度在海拔14.0—15.0 km,一例出现在负地闪初始击穿阶段的脉冲发生高度为海拔6.4 km。67例正极性窄脉冲发生高度位于海拔7—12 km,平均海拔9.4 km。利用传输线电流模式以及偶极子辐射近似估计了电流在通道内传播时间以及放电电流参数,78例平均结果显示电流从通道底部传播到顶部经历的时间约1μs,电流矩约为5 kA.km量级。我们推断放电通道长度约100—300 m,放电电流幅度具有20 kA量级,电流传播速度与光速可比拟、具有108m/s量级。  相似文献   

10.
闪电先导三维自持发展模式的建立   总被引:2,自引:1,他引:1       下载免费PDF全文
为研究上行先导发生发展的特征及其与地面构筑物间的相互作用,该文建立了闪电先导三维自持发展模式。该模式能够在给定雷暴云下空间电场初始分布情况、下行梯级先导始发位置及地面构筑物几何形状等参量时,进行自持发展模拟,计算出上行正先导随时间在三维空间内的头部位置、速度、电流强度、线电荷密度等物理特征量的变化。模拟发现上行正先导始发及发展过程中,其速度呈逐渐增加趋势,临近最后一跳发生前,上行正先导速度增加明显,整个过程中先导速度的变化范围为104~106 m·s-1量级,电流强度随时间也具有逐渐增加趋势,该变化趋势与光学观测得到的先导头部亮度的变化趋势相一致。该闪电先导三维自持模拟模型能够为进一步研究雷击地面构筑物特点提供参考。  相似文献   

11.
This study investigates an abnormal artificially triggered lightning event that produced two positive upward propagations: one during the initial stage (i.e., the upward leader (UL)) and the other after a negative downward aborted leader (DAL). The triggered lightning was induced in a weak thunderstorm over the experiment site and did not produce a return stroke. All of the intra-cloud lightning around the experiment site produced positive changes in the electric field. The initial stage was a weak discharge process. A downward dart leader propagated along the channel produced by the first UL, ending at a height of approximately 453 m and forming a DAL. Under the influence of the DAL, the electric field at a point located 78 m from the rod experienced a steady reduction of about 6.8 kV m-1 over 5.24 ms prior to the initiation of a new upward channel (i.e., the second upward propagation (UP)). The second UP, which started approximately 4.1 ms after the termination of the DAL and propagated along the original channel, was triggered by the DAL and sustained for approximately 2.95 ms. Two distinct current pulses were superimposed on the current of the second UP. The first pulse, which was related to the sudden initiation of the second UP, was characterized by a more rapid increase and decrease and a larger peak value than the second pulse, which was related to the development of the second UP into the area affected by the DAL. The second UP contained both a similar-to-leader process and a following neutralization process. This study introduces a new type of triggering leader, in which a new upward discharge is triggered in an established channel by an aborted leader propagating along the same channel with opposite polarity and propagation direction.  相似文献   

12.
闪电初始预击穿过程辐射脉冲特征及电流模型   总被引:5,自引:5,他引:0       下载免费PDF全文
利用2012年青海大通地区高精度闪电三维辐射源定位结果和宽带电场脉冲波形同步数据,基于3种改进的传输线模型和粒子群优化算法,拟合发生在不同距离上不同类型闪电初始预击穿过程的双极性脉冲波形结构,反演初始流光通道内电流波形和特征参数,对比分析3种模型对初始预击穿过程和梯级先导双极性脉冲波形的拟合效果,统计分析4类闪电初始预击穿脉冲的物理特征。结果表明:3种改进的传输线模型均能较好地拟合出双极性脉冲结构,且MTLE模型更合理。负地闪的初始预击穿过程和梯级先导过程呈现出相同的传输特征,即均以梯级形式发展,且拟合物理参量也较为接近。初始流光向上的路径长度大于初始流光向下的路径长度,初始流光向上击穿进入上部正电荷区的路径上中和的总电荷量和总垂直偶极矩远大于初始流光向下的路径上中和的总电荷量和总垂直偶极矩。  相似文献   

13.
2006—2011年广州人工触发闪电   总被引:1,自引:1,他引:0       下载免费PDF全文
2006—2011年夏季在广州野外雷电试验基地开展了广东综合闪电观测试验 (GCOELD)。试验期间,针对人工触发闪电进行了近距离声、光、电、磁特征等综合测量,对自动气象站电源线和信号线上产生的感应电压特征进行了观测和分析,并对广东省地闪定位网的探测效率和定位精度与人工触发闪电进行了比对和校验。试验结果表明:人工触发闪电回击峰值电流范围为-31.93~-6.67 kA,回击电流波形的半峰宽度的范围为6.18~74.19 μs,10%—90%的上升时间范围为0.24~2.25 μs。触发闪电的上行正先导的发展速度在104~105 m/s量级;人工触发闪电的回击过程在架空电源线路 (1200 m长,2 m高) 上产生的感应过电压可达十几千伏;广东电网闪电定位系统对人工触发闪电事件的探测效率为95%,平均定位误差为759 m,闪电定位系统反演得到的电流峰值与实际测量的电流峰值平均相对偏差为16.3%。  相似文献   

14.
地闪不规则先导的多尺度熵特征   总被引:2,自引:2,他引:0       下载免费PDF全文
针对不规则脉冲簇难以判别问题,将多尺度熵应用于不规则先导分析中,探讨闪电信号不规则脉冲分析应用中多尺度熵关键参量的选择方法。在此基础上,将不规则先导与直窜先导及梯级先导闪电信号的多尺度熵进行比较。统计分析表明:不规则先导和直窜先导熵值随尺度先增加后趋于平稳,但熵值有很大差异;梯级先导熵值随尺度变化不明显,整体呈增长趋势,与不规则先导的熵值在大于3的尺度上也有所差异,因此当尺度大于3时可将熵值大于1.5的先导归类为不规则先导,熵值小于1.5的先导归类为梯级先导或直窜先导。不规则先导的特征熵平均值为2.0~2.1,最大值范围为2.6~2.8,最小值范围为1.51~1.59。  相似文献   

15.
The initial discharge stages of two flashes during the Shandong Artificially Triggering Lightning Experiment (SHATLE) are analyzed based on the synchronous data of the current and close electromagnetic field. For a lightning flash, named 0503, the wire was connected, not electrically, but via a 5 m length of nylon, with the lightning rod; while for another, named 0602, the wire was connected with the rod directly. Results show that the discharge processes of the initial stage (IS) in flash 0503 are quite different from that of the usual classical-triggered flash 0602 and altitude-triggered flashes. A large pulse with a current of about 720 A resulted from the breakdown of the 5 m air gap during flash 0503, and the corresponding electric field at 60 m from the lightning rod was 0.38 kV/m. The upward positive leaders (UPLs) propagated continuously from the tip of the rocket after this breakdown. The geometric mean (GM) of the UPL peak current was 23.0 A. Vaporization of the wire occurred during the initial continuous current (ICC) stage and the largest current pulse was about 400 A. Compared with triggered flash 0503, the discharge processes of IS in flash 0602 were simple, only two large pulses similar to each other occurred before dart leader/return stroke sequences. The peak current of the first pulse was 2.1 kA and its corresponding electric field and magnetic field at a distance of 60 m from the lightning rod were 0.98 kV/m and 7.03 μT, respectively. During the second pulse, the wire disintegrated. The current decreased to the background level at the moment of the wire disintegration. The current of the second pulse in triggered flash 0602 was 2.8 kA, and the corresponding electric field and magnetic field at 60 m from the lightning rod were 1.22 kV/m and 9.01 μT, respectively.  相似文献   

16.
云闪K过程的三维时空特征   总被引:3,自引:3,他引:0       下载免费PDF全文
K过程是闪电放电过程中的一种放电事件。该文使用两套VHF宽带干涉仪2010年夏季在广州从化地区获取的3次云闪三维闪电辐射源定位数据,分析其中的K过程时空发展特征与地面电场特征。结果表明:宽带干涉仪观测到的K过程主要由快速发展的负极性放电事件组成,按定位结果的分布可划分为3个阶段:负极性反冲先导发生在云闪起始区域下方,沿正先导一端已有路径向闪电起始区域传播;部分反冲先导能进入之前负先导建立的通道并快速发展;反冲先导将原有通道激活后进一步促进负先导继续发展。同时使用辐射源三维定位数据计算了8次反冲先导的平均发展速度,反冲先导的发展速度为106~107 m·s-1量级,与负地闪中的负极性直窜先导相似,但均小于回击速度。  相似文献   

17.
人工触发闪电放电电流的间接测量及其特征分析   总被引:2,自引:3,他引:2  
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号