首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Parameterization of evaporation from a non-plant-covered surface is very important in the hierarchy strategy of modelling land surface processes. One of the representations frequently used in its computation is the resistance formulation. The performance of the evaporation schemes using the , , and their combination resistance approaches to parameterize evaporation from bare soil surfaces is discussed. For that purpose, the nine schemes, based on a different dependence of and on volumetric soil moisture content and its saturated value, are used.The tests of performances of the considered schemes are based on time integrations by the land surface module (BARESOIL) using observed data. The 23 data sets at a bare surface experimental site in Rimski anevi, Yugoslavia on chernozem soil, were used for the resistance algorithm evaluation. The quality of the schemes was compared with the observed values of the latent heat flux using several statistical parameters.  相似文献   

2.
Radiative Heat Transfer and Hydrostatic Stability in Nocturnal Fog   总被引:1,自引:0,他引:1  
We have performed a one-dimensional and transient radiative heat transfer analysis in order to investigate interaction between atmospheric radiation and convective instability within a nocturnal fog. The radiation element method using the Ray Emission Model (REM2), which is a generalized numerical method, in conjunction with a line-by-line (LBL) method, is employed to attain high spectral resolution calculations for anisotropically scattering fog. The results show that the convective instability has a strong dependence on radiative properties of the fog. For the condition of a 20-m droplet diameter and liquid water content of 0.1 × 10–3 kg m–3;, the temperature profile within the fog becomes S shaped, and a convective instability layer forms in the middle or lower level of the fog. However, for the same water content and a 40-m diameter droplet, no strong convective instability layer forms, whereas for a 10-m diameter droplet a strong convective instability is observed.  相似文献   

3.
The standard E – model generates aplanetary boundary layerthat appears to be much too deep. The cause of theproblem is traced to the equation for the dissipationrate () of turbulent kinetic energy (E), specifically theparameterization of dissipation production anddestruction. In the context of atmosphericboundary-layer modelling, we argue that a part of thedissipation production should be modelled as the inputto the spectral cascade from the energy-containingpart of the spectrum, with a characteristic length , while the equilibrium imbalancebetween local production and destruction ofdissipation is modelled as proportional toE2/E, as in the standard model. Wepropose an E – – turbulence closurescheme, in which both the mixing length, m, and are prescribed. The importance ofthe equation is diminished, though itstill determines the dissipation rate in the Eequation.  相似文献   

4.
The study focuses on a way to parameterize the effect of subgrid scale convective motions on surface fluxes in large scale and regional models for the case of light surface winds. As previously proposed, these subgrid effects are assumed to scale with the convection intensity through the relationship: where is the mean velocity of the wind, U0 the velocity of the mean wind, w* the free convection velocity, and an empirical coefficient to be determined. Both observations and numerical simulation are presently used to determine the free convection coefficient .Large eddy simulation of a fair weather convective boundary layer case observed during TOGA-COARE is performed. Comparisons between observations and the simulation of surface properties and vertical profiles in the planetary boundary layer are presented. The simulated vertical turbulent fluxes of heat, moisture and buoyancy range well within estimates from aircraft measurements.The most important result is that the true free convection coefficient , directly estimated from simulation, leads to a value of 0.65, smaller than the ones estimated from temporal and spatial variances. Using observations and simulation, estimates of from temporal and spatial variances are obtained with similar values 0.8. From both theoretical derivations and numerical computations, it is shown that estimates of the true from variances are possible but only after applying a correction factor equal to 0.8. If this correction is not used, is overestimated by about 25%. The time and space sampling problem is also addressed in using numerical simulations.  相似文献   

5.
An investigation is made of the detailed kinematic conditions which characterize breaking of internal waves in a continuous density field. It has been observed that breaking is associated with localized, abruptly appearing intensifications of the density gradient. Turbulence subsequently develops from these intensifications or traumata.Interactions between two or more disparate waves produce distortions more extreme than would be deduced from linear combination. This is exploited experimentally by crossing two weak internal wave beams from separate sources.Lagrangian integration of the motion field defined by the beams gives extrema of isopycnic slope, Richardson number defined by shear across isopycnics and dynamic vertical density gradient, and dynamic density gradient, under conditions for the appearance of traumata.  相似文献   

6.
Zusammenfassung An einem Material von 100 Fällen eindeutig gesicherten Herztodes, die im Institut für Gerichtliche und Soziale Medizin in Frankfurt am Main aus einem bestimmten Bereich — Raum Frankfurt am Main — und einer bestimmten zeit—Kalenderjahre 1948 bis 1950—zur Autopsie gelangten, einerseits und den bioklimatischen Daten für den gleichen Raum und die gleiche Zeit anderseits, wurde der Zusammenhang von Herztodesfällen und Wettervorgängen mit der Wahrscheinlichkeitsüberlegung, dem Wahrscheinlichkeitsintegral und formalstatistischen Methoden überprüft. Die Auswertung ergab, daß eine starke Abhängigkeit des Herztodes vom Wettergeschehen besteht. Die Häufung der Herztodesfälle konnte für die Sammelgruppe Wetterstörungen, für labiles Aufgleiten, Warmfront mit Aufgleiten und Kaltfront mit Turbulenz ebenso eindeutig gesichert werden, wie die Verminderung der Herztodesfälle in störungsfreien Zeiten. Die hohe Wahrscheinlichkeit einer Beziehung besteht ferner für Kaltfront mit Aufgleiten und in geringerem Maße auch für Föhndurchbruch. Während bei Okklusion das Material zu einem abschließenden Urteil zu gering war, konnte bei allen übrigen Wetterlagen eine Beziehung zum plötzlichen Herztod nicht nachgewiesen werden. Auch für die Gruppen, bei denen eine enge Beziehung statistisch gesichert werden konnte, sei betont, daß die Wettervorgänge nicht die alleinige Ursache des plötzlichen Herztodes, sondern nur ein auslösendes Moment bei schon vorher schwer geschädigten Herzen darstellen.
Summary On the basis of 100 ascertained cases of cardiac death from a certain region—province Frankfort on-the-Main—and a certain period—calendar years 1948 to 1950—, submitted to autopsy in the Institute for Legal and Social Medicine at Frankfort on-the-Main, and of bioclimatic data from the same region and period, the relation between cardiac death and meteorological phenomena was examined by means of probability considerations, the probability integral, and methods of formal statistics. Evaluation of this material showed cardiac death to be strongly dependent on weather conditions. Increase of frequency of cardiac death could be established without any doubt for the collective groups weather disturbances, unstable ascending motion, warm front with ascending motion, cold front with turbulence, whereas decrease of frequency was found in undisturbed periods. Furthermore, high probability of an existing relation was found for cold front with ascending motion and, to a lesser degree, also for foehn invasion. As to occlusion no definite conclusions could be drawn for scarcity of observations. For all the other weather types no relation to sudden cardiac death could be proved. Meteorological phenomena are by no means the only cause of sudden cardiac death, not even for the groups in which a close relation could be established statistically. They have but an initiatory effect in case of prior severe heart diseases.

Résumé Disposant d'un matériel médical de 100 cas de mort cardiaque qui ont fait l'objet d'autopsies à l'Institut de médecine légale et sociale de Francfort sur le Mein (région de Francfort et période de 1948 à 1950), et disposant d'autre part pour la même région et pour la même période d'observations bioclimatologiques, l'auteur a étudié la relation de ces décès avec les phénomènes météorologiques à l'aide des méthodes modernes de statistique, de l'intégrale de probabilité etc. Le résultat montre une étroite dépendance centre les cas de mort cardiaque et les conditions météorologiques. On a pu vérifier sans doute possible l'augmentation des décès lors de «perturbations», d'«ascendances labiles», de «fronts chauds avec glissement ascendant», de «fronts froids avec turbulence», de même que leur diminution lors de périodes non troublées. La forte corrélation subsiste avec les «fronts froids avec ascendance» et à un moindre degré avec «l'invasion du foehn». Tandis que pour les «occlusions» le matériel disponible était trop restreint pour aboutir à une conclusion, l'examen des situations autres que les précédentes n'a pas conduit à une relation intime. Il convient de remarquer que pour tous les groupes de météores ayant donné une corrélation statistique très nette, les phénomènes météorologiques n'ont joué qu'un rôle déclancheur chez des malades déjà gravement atteints.


Mit 2 Textabbildungen.  相似文献   

7.
The relationship between potential evaporation and arealevaporation is assessed using a closed-box model of the convectiveboundary layer (CBL). Potential evaporation is defined as theevaporation that would occur from a hypothetical saturated surface,with radiative properties similar to those of the whole area, and smallenough that the excess moisture flux does not modify thecharacteristics of the CBL. It is shown that the equilibrium rate ofpotential evaporation is given by Ep0=E0,where E0 is the equilibrium evaporation (radiative termof the Penman formula), and is a coefficient similar to thePriestley-Taylor coefficient. Its expression is , where is the areal surface resistance, ra is the localaerodynamic resistance, and is the dimensionless slope of thesaturation specific humidity at the temperature of the air. Itscalculated value is around 1 for any saturated surface surrounded bywater, about 1.3 for saturated grass surrounded by well-watered grassand can be greater than 3 over saturated forest surrounded by forest.The formulation obtained provides a theoretical basis to the overallmean value of 1.26, empirically found by Priestley and Taylor for thecoefficient . Examining, at the light of this formulation, thecomplementary relationship between potential and actual evaporation(as proposed by Bouchet and Morton), it appears that the sum ofthese two magnitudes is not a constant at equilibrium, but depends onthe value of the areal surface resistance.  相似文献   

8.
Increasing reliance on natural gas (methane) to meet global energy demands holds implications for atmospheric CO2 concentrations. Analysis of these implications is presented, based on a logistic substitution model viewing energy technologies like biological species invading an econiche and substituting in case of superiority for existing species. This model suggests gas will become the dominant energy source and remain so for 50 years, peaking near 70 percent of world supply. Two scenarios of energy demand are explored, one holding per capita consumption at current levels, the second raising the global average in the year 2100 to the current U.S. level. In the first (efficiency) scenario concentrations peak about 450 ppm, while in the second (long wave) they near 600 ppm. Although projected CO2 concentrations in a methane economy are low in relation to other scenarios, the projections confirm that global climate warming is likely to be a major planetary concern throughout the twenty-first century. A second finding is that data on past growth of world per capita energy consumption group neatly into two pulses consistent with longwave theories in economics.  相似文献   

9.
Thermal comfort of man in different urban environments   总被引:2,自引:4,他引:2  
Summary On July 29, 1985, a hot summer day, biometeorological measurements were performed simultaneously in three different urban structures within the city of Munich and in the trunk space of a nearby tall spruce forest. Based on the results of these experiments the following thermophysiologically relevant biometeorological indices were calculated: Predicted mean vote, skin wettedness and physiologically equivalent temperature. These three indices are derived from different models for the human energy balance. They allow the assessment of the thermal components of the microclimates at the selected sites with regard to application in urban planning. The results quantitatively show the great heat stress in the urban structure street canyon, exposed to south, whereas in the trunk space of the tall spruce forest there is nearly an optimal climate even on hot summer days. Between these extremes the results for street canyon, exposed to north show a little higher heat load than for backyard with trees.
Zusammenfassung An einem heißen Sommertag, dem 29. Juli 1985, wurden in drei Stadtstrukturen in München und im Stammraum eines nahegelegenen Fichtenhochwaldes zeitgleich biometeorologische Messungen durchgeführt. Mit den Meßergebnissen wurden folgende thermophysiologisch relevante biometeorologische Indizes berechnet: Predicted mean vote, Hautbenetzungsgrad und physiologisch äquivalente Temperatur. Diese drei Indizes beruhen auf verschiedenen Modellen zur menschlichen Energiebilanz. Mit den drei Indizes wurden die thermischen Komponenten der Mikroklimate an den ausgewählten Meßplätzen im Hinblick auf Stadtplanungsaufgaben bewertet. Die Ergebnisse zeigen quantitativ die relativ große Hitzebelastung bei der Stadtstruktur Straßenschlucht, nach Süd exponiert, während im Stammraum des Fichtenhochwaldes selbst an heißen Sommertagen nahezu optimale Bedingungen herrschen. Zwischen diesen Extremen liegen die Ergebnisse für die anderen Meßplätze, wobei für Straßenschlucht, nach Nord exponiert die Wärmebelastung etwas höher als für Innenhof mit Bäumen ist.


With 6 Figures  相似文献   

10.
Recently Wilson and Flesch (Boundary-Layer Meteorology, 84, 411-426, 1997) suggested that the average increment d z to the orientation = arctan(w/u) of the Lagrangian velocity-fluctuation vector can be used to distinguish the better Lagrangian stochastic models within the well-mixed class. Here it is demonstrated that the specification of d z constitutes neither a sufficient or universally applicable criterion to distinguish the better Lagrangian stochastic models within the well-mixed class. The hypothesis made by Wilson and Flesch that Lagrangian stochastic models with /PE irrotational are zero-spin models, having d z=0, is proven  相似文献   

11.
Stable Isotope Ratios: Hurricane Olivia   总被引:1,自引:0,他引:1  
The oxygen and hydrogen isotopic compositions of rains from HurricaneOlivia (1994) in the eastern Pacific were measured. The rains werecollected on 24 and 25 September during airplane flights conducted at anelevation of 3 km. Hurricane Olivia peaked in intensity to a category-4storm between the two dates. Isotope ratios of rains from HurricaneOlivia were markedly lower ( 18O = –13.9to –28.8) than that of rain collected from a thunderstormat an elevation of 2.3 km outside the influence of Olivia (18O = –3.8). A distinct decrease in isotoperatios from the first day to the next ( 18O =–18.4 to –21.9) in Hurricane Olivia wasattributed to decreased updraft velocities and outflow aloft. Thisshifted the isotopic water mass balance so that fewer hydrometeors werelifted and more ice descended to flight level. A decrease in the averagedeuterium excess from the first day to the next (d = 15.5 to 7.1)was attributed to an increase in the relative humidity of the watervapor `source' area. We hypothesize that the `source' region for therain was in the boundary layer near the storm center and that becausethe hurricane was at peak intensity prior to the second day the relative humidity was higher.  相似文献   

12.
An alternative analysis of flux-gradient relationships at the 1976 ITCE   总被引:7,自引:1,他引:7  
An extensive micrometeorological data set from the 1976 International Turbulence Comparison Experiment (ITCE) is analysed to determine flux-gradient relationships in an unstable atmosphere for momentum, sensible heat and water vapour transfers. The data are first analysed for internal consistency, resulting in the rejection of some data. Following a least-square fit to the remaining data in the form /k = (1 – z/L)-/k, rounded-off values of k, , and are selected for each form of transfer consistent with the statistical accuracy of the measurements. The equations finally adopted are M = (1 – 28z/L)-1/4 and H, W = (1 – 14z/L)-1/2 with k M = kH = kW = 0.40.These expressions fit the averaged observations to within a few per cent in the stability range of the experiment (-4 < z/L < -0.004).  相似文献   

13.
The influence of soil moisture on evaporation from a 6-m grass-covered lysimeter and from Class A pans was assessed for one summer using the -parameter of the Priestley-Taylor evaporation model appropriate for the individual surfaces computed on a daily basis. Net radiation over the pan was estimated from above-grass measurements using a correlation established between the two, using measurements made in the previous two summers. Changes in heat storage of the water were considered in the derivation of for the pan. A unique relationship for the particular conditions of the site was determined between the for the lysimeter and soil moisture, approaching 1.29 at soil moisture near field capacity, but decreasing to as low as 0.5 for dry soil. The corresponding relationship for the pan showed more scatter, but this was improved by using 5-day running means of evaporation and stratifying the data in terms of wind speed to yield a family of curves. Values for at wet soil conditions varied from 1.07 for 100 km day–1 wind run to 1.17 for 250 km day–1 wind run. For each curve, values of increased by about 20%; as the soil dried. The relationships may be used to reduce observed Class A pan evaporation to equivalent values for wet-soil conditions and to estimate near-surface soil moisture and actual evapotranspiration for this particular site. Extension of the technique to other areas requires derivation of similar relationships appropriate for those other locations  相似文献   

14.
The carbon isotopic ratio of atmospheric carbon dioxide at Tsukuba,Japan   总被引:1,自引:0,他引:1  
To find out the secular and seasonal trends of the 13C value and CO2 concentration in the surface air and the determination of the 13C in the atmospheric CO2 collected at Tsukuba Science City was carried out during the period from July 1981 to October 1983. The monthly average of the 13C value of CO2 in the surface air collected at 1400 LMT ranged from -7.52 to \s-8.45 with an average of -7.96±0.25 and the CO2 concentration in the air varied from 334.5 l 1-1 to 359 l 1-1 with an average of 347.2±6.3 l 1-1. The 13C value is high in summer and low in winter and is negatively correlated with the CO2 concentration. In general, the relationship between the 13C and the CO2 concentration is explainable by a simple mixing model of two different constant carbon isotopic species but the relationship does not always follow the model. The correlation between the 13C value and the CO2 concentration is low during the plant growth season and high at other times. The observed negative deviation of the 13C value from the simple mixing model in the plant growth season is partly due to the isotopic fractionation process which takes place in the land biota.  相似文献   

15.
Zusammenfassung Es werden numerische Integrationen der dreidimensionalen Fickschen Diffusionsgleichung mit höhenabhängigen Diffusionskoeffizienten und Windgeschwindigkeit für den stationären Fall und eine kontinuierlich emittierende Punktquelle durchgeführt. Für die drei typischen Ausbreitungsverhältnisse Starke Durchmischung, Bodeninversion und Inversion über der Quelle, charakterisiert durch die Diffusionskoeffizienten und die Windgeschwindigkeit, werden die Einflüsse unterschiedlicher Quellhöhe, Sinkgeschwindigkeit und Ablagerungsgeschwindigkeit studiert.
Summary Numerical integrations of the threedimensional Fickean diffusion equation with height dependent diffusion coefficients and wind velocity are performed in the stationary case with a continuous point source. For the three typical cases strong mixing, surface inversion and inversion above the source characterized by the diffusion coefficients and wind velocity, the effects of source height, sinking velocity and deposition velocity are discussed.

Résumé Les auteurs ont procédé à l'intégration numérique de l'équation à trois dimensions de la diffusion, équation établie par Fick. Ils ont, pour cela, utilisé des coefficients de diffusion variant avec l'altitude et la vitesse du vent et distingué l'état stationnaire et le cas d'une source d'émission ponctuelle et continue. Ils étudient en outre les influences de hauteurs différentes de la source, de la rapidité de subsidence et de la vitesse de sédimentation. Ils ont tenu compte pour cela des trois conditions typiques de diffusion mélange très accentué, inversion au sol et inversion au-dessus de la source.


Mit 7 Textabbildungen  相似文献   

16.
Summary The surface energy exchange of 12m high Scots pine plantation at Hartheim, Germany, was measured with a variety of methods during a 11-day period of fine weather in mid-May 1992. Net radiation and rate of thermal storage were measured with conventional net radiometers, soil heat flux discs and temperature-based storage models. The turbulent fluxes discussed in this report were obtained with an interchanging Bowen ratio energy budget system (BREB, at 14 m), two one-propeller eddy correlation systems (OPEC systems 1 and 2 at 17m), a 1-dimensional sonic eddy correlation system (SEC system 3) at 15 m, all on one low tower, and a 3-dimensional sonic eddy correlation system (SEC system 22) at 22 m on the high tower that was about 46 m distant. All systems measured sensible and latent heat (H and LE) directly, except for OPEC systems 1 and 2 which estimated LE as a residual term in the surface energy balance. Closure of turbulent fluxes from the two SEC systems was around 80% for daytime and 30% for night, with closure of 1-dimensional SEC system 3 exceeding that of 3-dimensional SEC system 22. The night measurements of turbulent fluxes contained considerable uncertainty, especially with the BREB system where measured gradients often yielded erroneous fluxes due to problems inherent in the method (i.e., computational instability as Bowen's ratio approaches –1). Also, both eddy correlation system designs (OPEC and SEC) appeared to underestimate |H| during stable conditions at night. In addition, both sonic systems (1- and 3-dimensional) underestimated |LE| during stable conditions. The underestimate of |H| at night generated residual estimates of OPEC LE containing a phantom dew error that erroneously decreased daily LE totals by about 10 percent. These special night problems are circumvented here by comparing results for daytime periods only, rather than for full days. To summarize, turbulent fluxes on the low tower from OPEC system 2 and the adjacent SEC system 3 were in reasonable agreement, while the BREB system appeared to overestimate H and underestimate LE; H and LE measured by SEC system 22 on the high tower were lower than from OPEC and SEC3 on the low tower. The turbulent flux measurements tended to converge, but the data exhibit unexplained differences between days, between systems, and between locations.With 7 Figures  相似文献   

17.
Summary The role of fog events for acid production and moist deposition in southern Germany during three EUMAC Joint Cases has been investigated by analysis of routine measurements and simulations with a one-dimensional fog-chemistry model. To identify the chemical and meteorological conditions, routine measurements by different institutions have been interpreted. The periods under consideration include a smog episode with low photooxidant concentrations during the Winter Case in February 1982. The Wet Case in spring 1986 represents a period with higher photooxidant concentrations. Conditions which are mostly characterized by low SO2 and oxidant concentrations and comparatively high pH-values in the fog are given during the SANA 1 case in autumn 1990. Fog mostly occurs as a subscale phenomenon, but sometimes it can also cover large areas and it can contribute significantly to moist deposition.The model results indicate that the liquid phase sulfate production in the fog layer may even exceed the gas phase production during 24 hours within a layer of the same height occasionally. On the other hand, during the SANA 1 case the sulfate production in the fog was extremely low at night due to lack of oxidants and SO2. Depending on the dissipation time of the fog a remarkable effect on the photolysis rates is possible. Since a significant amount of particulate mass is lost by moist deposition during fog, it is evident that fog events can have a noticeable effect on some of the gas phase constituents which are easily soluble.With 17 Figures  相似文献   

18.
The Langevin equation is used to derive the Markov equation for the vertical velocity of a fluid particle moving in turbulent flow. It is shown that if the Eulerian velocity variance wE is not constant with height, there is an associated vertical pressure gradient which appears as a force-like term in the Markov equation. The correct form of the Markov equation is: w(t + t) = aw(t) + b wE + (1 – a)T L ( wE 2)/z, where w(t) is the vertical velocity at time t, a random number from a Gaussian distribution with zero mean and unit variance, T L the Lagrangian integral time scale for vertical velocity, a = exp(–t/T L), and b = (1 – a 2)1/2. This equation can be used for inhomogeneous turbulence in which the mean wind speed, wE and T L vary with height. A two-dimensional numerical simulation shows that when this equation is used, an initially uniform distribution of tracer remains uniform.  相似文献   

19.
Whether in classical networks such as meteorological networks of in more recent ones of atmospheric chemistry, a wealth of data is at hand. These data have been evaluated in a manner depending on the purpose of the network. However, much more information is hidden in these time series and waits for discovery. Only the imagination of scientists is needed. Four examples are given which lead to new information about the atmospheric aerosol and the behaviour of the atmosphere. These examples are: Atmospheric turbidity from sunshine recordings, Meteorological drainage area from the variance of observations, Location of point sources from air mass trajectories, and Total vertical ozone from turbidity measurements.  相似文献   

20.
Cloud water and interstitial aerosol samples collected at Mt. Sonnblick (SBO) were analyzed for sulfate and aerosol carbon to calculate in-cloud scavenging efficiencies. Scavenging efficiencies for sulfate (SO) ranged from 0.52 to 0.99 with an average of 0.80. Aerosol carbon was scavenged less efficiently with an average value (AC) of 0.45 and minimum and maximum values of 0.14 and 0.81, respectively. Both SO and AC showed a marked, but slightly different, dependence on the liquid water content (LWC) of the cloud. At low LWC, SO increased with rising LWC until it reached a relatively constant value of 0.83 above an LWC of 0.3 g/m3. In the case of aerosol carbon, we obtained a more gradual increase of AC up to an LWC of 0.5 g/m3. At higher LWCs, _ remained relatively constant at 0.60. As the differences between SO and A varied across the LWC range observed at SBO, we assume that part of the aerosol carbon was incorporated into the cloud droplets independently from sulfate. This hypothesis is supported by size classified aerosol measurements. The differences in the size distributions of sulfate and total carbon point to a partially external mixture. Thus, the different chemical nature and the differences in the size and mixing state of the aerosol particles are the most likely candidates for the differences in the scavenging behavior.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号