首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A combination of vertical electrical soundings (VES), 2D electrical resistivity imaging (ERI) surveys and borehole logs were conducted at Magodo, Government Reserve Area (GRA) Phase 1, Isheri, Southwestern Nigeria, with the aim of delineating the different aquifers present and assessing the groundwater safety in the area. The Schlumberger electrode array was adopted for the VES and dipole-dipole array was used for the 2D imaging. The maximum current electrode spread (AB) was 800 m and the 2D traverse range between 280 and 350 m in the east-west direction. The thickness of impermeable layer overlying the confined aquifer was used for the vulnerability ratings of the study area. Five lithological units were delineated: the topsoil, clayey sand, unconsolidated sand which is the first aquifer, a clay stratum and the sand layer that constitutes the confined aquifer horizon. The topsoil thickness varies from 0.6 to 2.6 m, while its resistivity values vary between 55.4 and 510.6 Ω/m. The clayey sand layers have resistivity values ranging from 104.2 to 143.9 Ω/m with thickness varying between 0.6 and 14.7 m. The resistivity values of the upper sandy layer range from 120.7 to 2195.2 Ω/m and thickness varies from 3.3 to 94.0 m. The resistivity of the clay layer varies from 11.3 to 96.1 Ω/m and the thickness ranges from 29.6 to 76.1 m. The resistivity value of the confined aquifer ranges between 223 and 1197.4 Ω/m. The longitudinal conductance (0.0017–0.02 mhos) assessment of the topsoil shows that the topsoil within the study area has poor overburden protective capacity, and the compacted impermeable clay layer shows that the underlying confined aquifer is well protected from contamination and can be utilized as a source of portable groundwater in the study area. This study therefore enabled the delineation of shallow aquifers, the variation of their thicknesses and presented a basis for safety assessment of groundwater potential zones in the study area.  相似文献   

2.
This research is an attempt to accomplish a 3-D resistivity imaging survey, which was carried out near a water well contaminated with hydrocarbon materials in Karbala governorate. Two-dimensional resistivity imaging measurements were collected along four parallel profiles, using a Wenner array with electrode spacing of 1 m. The RES3DINV program was used to invert the apparent resistivity data. The results displayed a resistivity distribution of the subsurface in a three-dimensional volume. Thus, both the horizontal and vertical extents of the contaminated zone were displayed. This technique revealed a low resistivity zone at depth ranges from 3 to 6 m in the investigation area, but the seepage starts at depth ranges between 2 and 3 m and continues down depth (may be to the groundwater level). This low resistivity zone is the most likely location for a subsurface seepage of contaminated water. It is clear that the sufficient measurement points along 2-D lines in a small area can increase the 3-D imaging resolution, and nearly real 3-D imaging can be achieved, when the size of subsurface anomaly compared with the electrode spacing (a) of the Wenner array is taken into consideration.  相似文献   

3.
The vertical electrical sounding (VES) survey was carried out by using Schlumberger array in (12) points distributed along two profiles, except VES 6 was not located within any profile. The 2D imaging survey was carried out using Wenner array in four stations. The VES results revealed the presence of two groundwater aquifers. The first is Euphrates aquifer and the second is Dammam aquifer. While the results of 2D imaging survey distinguished two secondary aquifers in addition to previous aquifers located within Dammam formation. Also, 2D imaging gave a more accurate picture for the distribution of electrical horizons especially for the depths which ranges between 2.5 and 73 m. While the VES gives information for larger depths than that of 2D, which ranges between the earth’s surface and a depth 140 m. The geo-electrical sections of VES showed electrical horizons (layers) with sharp boundaries. But the 2D inverse models revealed the lateral and vertical variations of the resistivity within each horizon especially for shallow depths due to large volume of data available in 2D measurement. These variations were not shown in the geo-electrical sections of VES points. Comparison of VES and 2D imaging techniques revealed that the 2D imaging was the best for determined the shallow aquifers as observed from this study. It can be concluded that 2D resistivity imaging and VES can provide very useful guide for borehole drilling particularly where there is no existing well.  相似文献   

4.
In situ soil micro electrical resistivity measurements were carried out in a pilot plot within the Teaching and Research Farm of Ekiti State University with the aim of establishing relationships between such measurements, soil horizons, and textural classifications. The vertical electrical sounding (VES) technique was adopted for horizon mapping, while the horizontal profiling (HP) technique was used to determine the spatial distribution of in situ soil electrical resistivity of the topmost horizon. Twenty-five VES points were occupied with the Wenner electrode array and electrode spacing that was varied from 2 to 128 cm (0.02 to 1.28 m). The VES data were interpreted by partial curve matching and computer assisted 1-D forward modeling with the IPI2Win software. HP data were also acquired with the Wenner electrode array with a constant electrode separation of 8 cm and station interval of 1 m. Resistivity measurements were taken at 729 stations. The HP data were classified into resistivity-derived soil classes using a standard table. Eighty-one soil samples were collected from the topmost (0–3 cm) horizon and textural classification was derived from the particle size distributions. The resistivity range of values for the identified three layers was 38–590, 328–5222, and 393–900 Ω·m respectively. The average resistivities of the three layers were 263, 2554, and 703 Ω·m, with respective thicknesses of 2.85 cm, 45.52 cm, and infinite. The above resistivity regimes of the three horizons were attributed to responses from the O, A, and B soil horizons. The resistivity values of the O-horizon ranging from 210 to 750 Ω·m were classified as clayey sand while values greater than 750 Ω·m were classified as sand. The soil textural classifications obtained within the horizon were the sandy loam and loamy sand types. The cross-tabulation and spatial pattern comparison of resistivity-derived soil classes and textural classifications showed that whereas there existed some overlapping relationships, the sandy loam textural class had stronger association with the resistivity-derived clayey sand soil type, and the loamy sand textural class had stronger association with the more resistive sand soil type. This study therefore established that in situ soil electrical resistivity can be used for soil horizon mapping and textural classification.  相似文献   

5.
The use of resistivity sounding and two-dimensional (2-D) resistivity imaging was investigated with the aim of delineating and estimating the groundwater potential in Keffi area. Rock types identified are mainly gneisses and granites. Twenty-five resistivity soundings employing the Schlumberger electrode array were conducted across the area. Resistivity sounding data obtained were interpreted using partial curve matching approach and 1-D inversion algorithm, RESIST version 1.0. The 2-D resistivity imaging was also carried out along two traverses using dipole–dipole array, and the data obtained were subjected to finite element method modeling using DIPRO inversion algorithm to produce a two-dimensional subsurface geological model. Interpretation of results showed three to four geoelectrical layers. Layer thickness values were generally less than 2 m for collapsed zone, and ranged from 5 to 30 m for weathered bedrock (saprolite). Two major aquifer units, namely weathered bedrock (saprolite) aquifer and fractured bedrock (saprock) aquifer, have been delineated with the latter usually occurring beneath the former in most areas. Aquifer potentials in the area were estimated using simple schemes that involved the use of three geoelectrical parameters, namely: depth to fresh bedrock, weathered bedrock (saprolite) resistivity and fractured bedrock (saprock) resistivity. The assessment delineated the area into prospective high, medium and low groundwater potential zones.  相似文献   

6.
Integrated geophysical techniques including resistivity image, vertical electrical sounding (VES), and seismic refraction have been conducted to investigate the Wadi Hanifah water system. The groundwater in Wadi Hanifah has problems caused by the high volumes of sewage water percolating into the ground. The combination of VES, resistivity image, and seismic refraction has made a valuable contribution to the identification of the interface between the contaminated and fresh water in Wadi Hanifah area. The contaminated groundwater has lower resistivity values than fresh groundwater due to the higher concentration of ions which reduces the resistivity. Resistivity image and sounding in this area clearly identified the nature of the lithological depth and proved useful at identifying water-bearing zones. Fresh groundwater was found in the study area at a depth of 100 m within the fractured limestone. Water-bearing zones occur in two aquifers, shallow contaminated water at 10 m depth in alluvial deposits and the deeper fresh water aquifer at a depth of about 100 m in fractured limestone. The interface between the contaminated water (sanitary water) and fresh water marked out horizontally at 100 m distance from the main channel and vertically at 20 m depth.  相似文献   

7.
Until this study, the location and depth of the saline units in Uburu-Okposi salt lake areas and environs have been unknown. This study aimed at delineating the saline lithofacies and dispersal configurations to water bodies, using electrical geophysical methods such as constant separation traversing (CST) and vertical electrical sounding (VES). Results showed weathered zones that represent aquifers mostly at the fourth geoelectric layer: between upper layered aquitards and underlying aquitards at depths 30–140 m. Lateral distribution of resistivity variance was defined by the CST, whereas the VES tool, targeted at low-resistivity zones, detected isolated saline units with less than 10 ohm-m at depths generally >78 m. The saline lithofacies were suspected to link freshwater zones via shear zones, which steer saline water towards the salt lakes and influence the vulnerability of groundwater to salinization. The level of salinization was verified by water sampling and analysis, and results showed general alkaline water type with a mean pH of 7.66. Water pollution was indicated: mean total dissolved solids (TDS) 550 mg/l, electrical conductivity (EC) 510 μS/cm, salinity 1.1‰, Cl? 200 mg/l, N03 ?35.5 mg/l, Na+ 19.6 mg/l and Ca2+ 79.3 mg/l. The salinity is controlled by NaCl salt, as deduced from correlation analysis using the software package Statistical Product for Service Solutions (SPSS). Generally, concentrations of dissolved ions in the water of the area are enhanced via mechanisms such as evaporation, dissociation of salts, precipitation run off and leaching of dissolved rock minerals.  相似文献   

8.
The effectiveness of inversion apparent resistivity data to determine accurately the true resistivity distribution over 2D structures has been investigated using a common inversion scheme based on smoothness-constrained nonlinear least-squares optimization with enhancing horizontal resolution (EHR) technique by numerical simulation. The theoretical model generates in RES2DMOD software at specific distance and depth using Wenner, Wenner–Schlumberger, and pole–dipole arrays were inverted. The inversion model was compared with the original 2D model in RES2DINV software. The study model includes horizontal layering, vertical resolution, and horizontal two layers with different resistivity. Also, the response to variations in data density of these arrays was investigated. The study shows the best array suitable to be used in the survey was chosen for real data acquisition at the actual site. Subsequently, the results from borehole were used to verify the results of 2D resistivity imaging method with and without EHR technique. Saturated zone (0–40 Ω-m) was found scattered at the depth of 10–20 m. The borehole is located at 63 m at 2D resistivity imaging survey which shows at depth 10–20 m is sandy silt. Highly weathered sandstone was found at 6 m depth with resistivity value of 800 Ω-m and SPT N value of 20. The bedrock was found at 27 m depth with resistivity value of 3,000 Ω-m and SPT N value of 50. The application of 2D resistivity imaging with EHR technique indicate the ability of the proposed approach in terms of density, depth, and resistivity value of anomalous and layer in a computationally and numerically efficient manner and to exhibit good performance in the data inversion.  相似文献   

9.
As part of a larger regional research program “KarstEAU”, the authors have applied electrical resistivity tomography (ERT) techniques to characterize heterogeneities in the Port-Miou coastal karst aquifer (Cassis, SE France). Field surveys were carried out on intensely fractured and karstified Urgonian carbonates. Extensive research has characterized macro- and micro-scale geology of the Port-Miou area and particularly underground water-filled conduits and fault/fracture and karst systems within a former quarry. The authors applied 2D ERT along two surface profiles of length 420 and 595 m to test capability for delineating subsurface conduits and possibly relationship between conduit and fault/fracture/karst orientation; and 3D ERT with a dense 120 electrode array at 1 m spacing (11 × 10 m) was applied over an area of the quarry that had been profiled using 3D georadar and which has had intensive nearby structural geological interpretation. The 2D profiling imaged several underground conduits at depths to >50 m below ground surface and below sea level, including possibly the main Port Miou submarine spring and smaller springs. The 2D profiling within the quarry provided a better understanding of the connectivity between major fractures and faults on the quarry walls and secondary springs along the coast supporting flow of the secondary springs along interpreted fracture orientations. In addition, 2D inversion-derived conductivity models indicate that high resistivity zones above sea-level are associated with non-saturated zones and low resistivity anomalies in the non-saturated zone are associated with residual clays in paleokarsts. A partitioned lower resistivity zone below sea-level can be associated with a higher porosity/permeability zone with fractures and karstic features. Inversion models of the dense 3D ERT data indicate a higher resistivity volume within the larger surveyed block. The survey characterized the non-saturated zone and the ERT resistivities are correlated with karst features interpreted by 3D georadar and visible in the inferior wall of the quarry.  相似文献   

10.
Surface electrical and electromagnetic surveys were conducted on top of a solid waste facility in Unguwan Dosa, Kaduna State, Northwest Nigeria. The aim of the geophysical survey was to detect vertical and subvertical fractures that may provide pathways for groundwater and contaminant transport. Results from the 2D electrical resistivity imaging showed vertical and subvertical contacts overlain by 6–10 m thick overburden. Quantitative interpretation of the VLF-EM data correlates well with the results of the 2D resistivity imaging delineating the vertical and subvertical contacts as good and weak conductors (fractures zones) with resistivity values of 40–220 and 300–420 Ω m, respectively. Azimuthal Schlumberger VES measurements yield apparent anisotropy values ranging from 1.01 to 1.47 for electrode spacings of 1–45 m with the highest value recorded at spacing of 2 m. However, azimuthal variations at large spacings (30–45 m) showed no fracture anisotropy due possibly to the array’s low sensitivity to anisotropy at these spacings. The result of the study showed that pollutants in the leachate can reach and contaminate the groundwater. Therefore, urgency for leachate treatment at this site is recommended to prevent contamination of groundwater.  相似文献   

11.
A large number of valleys and basin systems are present in the northwestern part of the Himalayas in Pakistan which form significant aquifers in the region. Hydrogeophysical investigations in the western part of Nowshera District, a part of the intermontane Peshawar basin, were undertaken to help to determine the availability of groundwater resources in the region. Thirty vertical electrical resistivity soundings (VES) were acquired using a Schlumberger expanding array configuration with a maximum current electrode spacing (AB/2) of 150 m in delineating the groundwater potential in the study area. The results of the interpreted VES data using a combination of curve matching technique and computer iterative modeling methods suggest that the area is underlain by 3 to 5 geo-electric layers. The interpretation results showed that the geo-electrical succession consists of alluvium comprising of alternating layers of clay, silty clay, fine to coarse sands, sand with gravels and gravels of variable thickness. High subsurface resistivity values are correlated with gravel–sand units and low resistivity values with the presence of clays and silts. The modeled VES results were correlated with the pumping tests results and lithological logs of the existing wells. The pumping test suggests the transmissivity of the aquifer sediments is variable corresponding to different sediments within the area. The gravel–sand intervals having high resistivity value show high transmissivity values, whereas clay–silt sediments show low transmissivities. It is concluded that majority of the high resistive gravel–sand sediments belong to an alluvial fan environment. These gravel–sand zones are promising zones for groundwater abstraction which are concentrated in the central part of the study area.  相似文献   

12.
Recently, the deterioration of water quality in the coastal zones of Lekki Peninsula area of Lagos due to saltwater infiltration into the freshwater aquifer has become a major concern. With the aim of providing valuable information on the hydrogeologic system of the aquifers, the subsurface lithology and delineating the groundwater salinity, vertical electrical resistivity (VES) sounding survey was carried out utilizing surface Schlumberger electrode arrays, and electrode spacing varying between 1 and 150 m. The DC resistivity surveys revealed significant variations in subsurface resistivity. Also, the VES resistivity curves showed a dominant trend of decreasing resistivity with depth (thus increasing salinity). In general, the presence of four distinct resistivity zones were delineated viz.: the unconsolidated dry sand (A) having resistivity values ranging between 125 and 1,028 Ωm represent the first layer; the fresh water-saturated soil (zone B) having resistivity values which correspond to 32–256 Ωm is the second layer; the third layer (zone C) is interpreted as the mixing (transition) zone of fresh with brackish groundwater. The resistivity of this layer ranges from 4 to 32 Ωm; while layer four (zone D) is characterized with resistivities values generally below 4 Ωm reflecting an aquifer possibly containing brine. The rock matrix, salinity and water saturation are the major factors controlling the resistivity of the formation. Moreover, this investigation shows that saline water intrusion into the aquifers can be accurately mapped using surface DC resistivity method.  相似文献   

13.
Geoelectrical survey was carried out in the western delta region of River Vasista Godavari, Andhra Pradesh, India, for delineation of groundwater prospective zones due to acute shortage of water supply for various purposes. Forty-six vertical electrical soundings (VES) were done, employing the Schlumberger configuration with a maximum AB/2 of 160 m. The interpreted results of VES show four to five layers with variable thicknesses, such as topsoil zone (1.5–3 m), clay zone (0.84–32 m), finer sand zone (2–72 m), medium to coarse sand zone (4 to 28.8 m) and clay zone (1.2–∞ m), indicating a multi-aquifer system. These results are corroborated with the known lithologs of the study area. Further, the resistivity is also compared with electrical conductivity (EC) of groundwater observed nearby shallow wells representing buried channel (BC), flood plain (FP) and coastal (C) zones, which indicate slightly brackish to brackish water (EC: 1470–6010 µS/cm), whereas the groundwater observed from deep wells shows the fresh (EC: 726–1380 µS/cm), fresh to brackish (EC: 1010 to 3250 µS/cm), and brackish water (EC: 3020 to 4170 µS/cm) located in BC, FP and C zones, respectively. This survey reveals the prospective aquifer zones with potable water at VES locations of 4–6, 8, 10, 11, 14, 16–28, 33–36, 39 and 42–44, where the resistivity values vary from 10 to 40 Ω m. The slightly brackish and brackish water zones are also observed from the resistivity of less than 10 Ω m at shallow depth in BC (VES-22, 37, 38 and 46), FP (VES-1, 2, 7, 29, 30 and 40) and C (VES-3, 4, 9, 12, 13, 15, 31, 32, 41 and 45) zones. As a result, the present investigation has delineated the freshwater zones at shallow (<?12 m) and also at deeper depths (30–45 m) as prospective areas, where BC zone occurs. Freshwater pockets also identified in FP (VES-8 and 39) and C (VES-11, 14 and 15) zones. Thus, this study helps to solve the drinking and irrigation water problems.  相似文献   

14.
Water seepage to ground surface at a limestone quarry located at Wadi Garawy about 20 km south-east of Helwan city in Egypt posed a real threat to the mining activity at the quarry. The quarry area is known to be very dry for decades and away from water utilities and infrastructures that may cause water leaks to the quarry. Geophysical investigation including 1D Vertical Electrical Sounding (VES), 2D Electrical Resistivity Tomography (ERT) and 1D Transient Electromagnetic (TEM) surveys were conducted to characterize the rock sequence and locate what could be a possible source of water seepage to the quarry. The resistivity profiles generated from the VES and TEM surveys mapped the rock units in the area down to depths exceeded 100 m. The ERT profiles acquired from the quarrying zone close to the water seepage spot have imaged the top of groundwater level at few meters below the ground surface at the quarry open pit. The spot of groundwater seepage seemed to occur at an area of limestone dissolution that were filled by finer sediments. The finer sediments acted as a hydrological conduit that allowed an upward seepage of groundwater to ground surface under the capillary action effect.  相似文献   

15.
Frequent failures of monsoons have forced to opt the groundwater as the only source of irrigation in non-command areas. Groundwater exploration in granitic terrain of dry land agriculture has been a major concern for farmers and water resource authorities. The hydrogeological complexities and lack of understanding of the aquifer systems have resulted in the failure of a majority of the borehole drillings in India. Hence, a combination of geophysical tools comprising ground-penetrating radar (GPR), multielectrode resistivity imaging (MERI), and vertical electrical sounding (VES) has been employed for pinpointing the groundwater potential zones in dry land agricultural of granitic terrain in India. Results obtained and verified with each other led to the detection of a saturated fracture within the environs. In GPR scanning, a 40-MHz antenna is used with specifications of 5 dielectric constant, 600 scans/nS, and 40 m depth. The anomalies acquired on GPR scans at various depths are confirmed with low-resistivity ranges of 27–50?Ω m at 23 and 27 m depths obtained from the MERI. Further, drilling with a down-the-hole hammer was carried out at two recommended sites down to 50–70 m depth, which were complimentary of VES results. The integrated geophysical anomalies have good agreement with the drilling lithologs validating the MERI and GPR data. The yields of these bore wells varied from 83 to 130 l/min. This approach is possible and can be replicated by water resource authorities in thrust areas of dry land environs of hard rock terrain around the world.  相似文献   

16.
Groundwater is a very important component of water resources in coastal aquifers in Thoothukudi. It has been established that the groundwaters in the coastal zone of the Zirconium Complex, Pazhayakayal, Thoothukudi district, Tamilnadu, India, are subjected to wave and tidal impact. The groundwater quality was studied by hydrogeological methods, 2D electrical resistivity imaging (ERI) techniques (six profiles), 11 Wenner vertical electrical sounding (VES), and well log analysis. Also, nine geochemical water samples were taken from the study area. The 2D ERI and VES surveys were carried out using WGMD-4 Ltd., Chennai, resistivity meter, multicore cable, and multielectrodes with Wenner array. The collected resistivity data were interpreted using the Res2DINV software. The research shows that the groundwaters are the result of the paleoriver flow along the Tamirabarani Channel in the western area and of the seawater intrusion in the eastern area. The fresh water is characterized by resistivity of about 10–100 Ohm?m in the study area. The resistivity of 10–50 Ohm?m indicates that the subsurface section is made up of sand, clay, and caliche. Resistivity values of more than 200 Ohm?m are specific to sand dunes. The very low resistivity (<5 Ohm?m) layer might be due to the seawater intrusion in the study area. Six water samples from the well drilled in the coastal area were analyzed, which made it possible to determine the concentrations of major and trace elements in the groundwaters. These data were used to establish the seawater intrusion and coastal environment characteristics in the study area.  相似文献   

17.
The current study is carried out for the determination of groundwater potential in District Rawalakot Azad Jammu and Kashmir (AJ&K) Pakistan by using electrical resistivity method and petrographic analysis of the area. The tape-compass-clinometers method was used in section measurement to understand the facies and depositional environment. The electrical resistivity survey was carried out in the project area in sub-Himalayan Siwaliks system of Pakistan to overcome water scarcity in a few regions. The area was chartered with the Schlumberger configuration up to the AB/2 depth of 150 m. The ABEM Terrameter SAS 4000 (Sweden) and accessories were used to acquire vertical electrical soundings in 24 locations. The results obtained through the 2D and 3D isoresistivity maps of apparent resistivity for 15, 45, and 130 m spacings, the 3D isoresistivity maps of transverse resistance and anisotropy, the VES curve types, and the measured stratigraphic section of surface rocks revealed the confined or semi-confined type aquifers within sedimentary formations. The petrographic analysis indicates the clues of the secondary porosity and fluid migrations through the rocks.  相似文献   

18.
The objective of this study was to assess the subsurface strata and groundwater situation of Olomoro, Nigeria using borehole logging and electrical resistivity techniques. The borehole logging consisting of resistivity and spontaneous potential logs were conducted by using the Johnson Keck logger on a drilled well in the study area. The electrical resistivity survey involving 17 vertical electrical soundings (VES) with a maximum current electrode spacing of 100 to 150 m was conducted using the Schlumberger electrode configuration. Analysis of the well cuttings revealed that the lithology of the subsurface consist of topsoil, clay, very fine sand, medium grain sand, coarse sand and very coarse sand. Results of the downhole logging also revealed that the mean electrical conductivity and the total dissolved solid of the groundwater was obtained as 390 μS/cm and 245 mg/cm3 respectively. These values are within the acceptable limit set by the Standard Organization of Nigeria (SON) for drinking water. The result of the vertical electrical sounding interpreted using the computer iterative modeling revealed the presence of four to five geoelectric layers which showed a close correlation with result from the lithology and downhole logging. Results further showed that the resistivity of the subsurface aquifer ranged between 1584 and 5420 Ωm while the aquifer depths varied between 27.8 and 39.3 m. Groundwater development of the area is suggested using the depth and resistivity maps provided in this study.  相似文献   

19.
The study site lies on a karst system in the Pyrénées (France) that crosses the Urgonian limestones. Organic matter was dumped on the west bank of the River Vert d’Arette, which polluted a spring (the Fontaine d’Orbe) situated on the east bank. Electrical resistivity tomography was utilised in order to understand the geometry of this karst outlet. After tests with the pole-pole array, the ideal electrode spacing was found to be less than 3 m. A conduit, a little less than 10 m wide, was discovered, which proved to be the terminal conduit of the karst system. It was established that the conduit traverses both banks of the River Vert d’Arette, thus presenting a hydraulic link between the two sides. Moreover, this conduit, which is totally submerged, passes under the riverbed and goes upwards to the spring. In addition to the geophysical measurements, hydrogeological measurements and observations were made. Based on the characterisation of the geometry of the karst network’s terminal conduit, and the fact that is completely full of water and inclined, it is concluded that the Fontaine d’Orbe spring is of the Vauclusian variety.  相似文献   

20.
A groundwater flow and contaminant transport model was used to simulate arrays of non-pumped wells with reactive media for remediating contaminated groundwater. Each array featured a minimum number of wells, with identical diameter, capable of removing a contaminant plume within a hypothetical site. Simulated well diameters ranged from 0.25 m (similar to typical remediation wells) to 1.25 m (similar to large-diameter, bucket-augered wells). Both arrays occupied a linear transect located approximately 5 m downgradient of the front of a polluted enclave and oriented 90° to the hydraulic gradient. The minimum smallest diameter array contained 23 wells, whereas the minimum largest diameter array contained only four wells. Results of this study suggest that bucket-augering technology, adapted to install non-pumped wells with reactive media, may be an effective alternative for remediating contaminated groundwater in some environments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号