首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 180 毫秒
1.
El Bahariya Oasis is a part of the great groundwater reservoir of the Western Desert of Egypt. The different stratigraphic units, the water-bearing zones, aquifer potentiality conditions, and the favorable locations for drilling new wells were evaluated by carrying out 24 Schlumberger vertical electrical soundings (VESs), along with the data of some wells drilled in the near vicinity of the measuring sites. The results of the interpreted field data revealed the presence of ten distinctive subsurface geoelectric layers; a thin surface, dry loose sand and gravel, sandy clay and shale interclations, saturated coarse sand layer, shale and clay, and saturated fine sandstone and saturated coarse sandstone. The aquifer is a multilayer aquifer with different thicknesses represented by the fourth, sixth, eighth, and tenth geoelectric layers. Results also revealed that the thicknesses of the water-bearing horizons increase towards the east direction, consequently the aquifer potentiality increases. Therefore, the best production well locations are in that direction. Depth to water starts from 40 m at VES no. 14 and increases gradually toward the east to reach 66 m at VES no. 5. Hydrogeochemical analysis of two groundwater samples taken from Ein El Ezza and well no. 2 showed that groundwater in the study area is suitable for agricultural purposes but not for human consumption due to the high iron content. Recommendations concerning site selection for drilling new productive groundwater wells are given.  相似文献   

2.
A combination of vertical electrical soundings (VES), 2D electrical resistivity imaging (ERI) surveys and borehole logs were conducted at Magodo, Government Reserve Area (GRA) Phase 1, Isheri, Southwestern Nigeria, with the aim of delineating the different aquifers present and assessing the groundwater safety in the area. The Schlumberger electrode array was adopted for the VES and dipole-dipole array was used for the 2D imaging. The maximum current electrode spread (AB) was 800 m and the 2D traverse range between 280 and 350 m in the east-west direction. The thickness of impermeable layer overlying the confined aquifer was used for the vulnerability ratings of the study area. Five lithological units were delineated: the topsoil, clayey sand, unconsolidated sand which is the first aquifer, a clay stratum and the sand layer that constitutes the confined aquifer horizon. The topsoil thickness varies from 0.6 to 2.6 m, while its resistivity values vary between 55.4 and 510.6 Ω/m. The clayey sand layers have resistivity values ranging from 104.2 to 143.9 Ω/m with thickness varying between 0.6 and 14.7 m. The resistivity values of the upper sandy layer range from 120.7 to 2195.2 Ω/m and thickness varies from 3.3 to 94.0 m. The resistivity of the clay layer varies from 11.3 to 96.1 Ω/m and the thickness ranges from 29.6 to 76.1 m. The resistivity value of the confined aquifer ranges between 223 and 1197.4 Ω/m. The longitudinal conductance (0.0017–0.02 mhos) assessment of the topsoil shows that the topsoil within the study area has poor overburden protective capacity, and the compacted impermeable clay layer shows that the underlying confined aquifer is well protected from contamination and can be utilized as a source of portable groundwater in the study area. This study therefore enabled the delineation of shallow aquifers, the variation of their thicknesses and presented a basis for safety assessment of groundwater potential zones in the study area.  相似文献   

3.
Geophysical investigation using Vertical Electrical Sounding (VES), Electrical Resistivity Tomography (ERT) and Seismic Refraction at a proposed conference center site along Ajibode-Labani road, Ibadan, southwestern Nigeria has been carried out. The investigation aims at characterizing and delineating the subsurface strata to understand the weathered profile at the site. Understanding the weathered profile is essential in determining the suitability of the site for engineering construction of the future conference center. A total of 25 VES and 10 ERT profiles were acquired in a systematic grid pattern using both Schlumberger andWenner configurations with Allied omega terrameter. TheVES data were processed and analyzed using WinResist and the ERT data were inverted using RES2DINV. The data were combined to form a 3-D data set of the site and RES3DINV was used to produce the depth slices. Seismic refraction data were also acquired with an ABEM seismograph and processed using SeisImager and Fajseis software. Seismic data were used in understanding the velocity distribution and thickness. The results of VES, ERT and seismic refraction show good correlation. Four sub-surface layers were delineated: top layer of reworked sand, clayey sand/ lateritic hard pan, clay/ sandy clay and fracture/ fresh basement. The 3-D model permits a pictorial view of the sub-surface in relation to materials that overlie the basement. The thickness of unconsolidated materials to bedrock varies from 2.7 m to 12.2 m which revealed inhomogeneity in weathering under the shallow sub-surface. It is found that the integrated geophysical tool is well suited to characterize and delineate sub-surface structure (weathered profile) for engineering site characterization.  相似文献   

4.
Geoelectrical resistivity investigation using Vertical Electrical Sounding (VES) technique was conducted at Port Blair, South Andaman Island, to locate the fractures in different formations and to decipher its groundwater potential. A total of 40 VES were carried out covering the entire study area using Schlumberger electrode configuration out of which 34 VES fall in Andaman Flysch formations and the remaining VES in Ophiolite formations. The interpreted resistivity results were integrated with nine borehole lithologs for the subsurface analysis. The combination of VES with borehole litholog data has provided a close correspondence on subsurface hydrogeological conditions. The interpreted VES data of various formations showed drastic variations in the resistivity ranging from higher in Ophiolite, moderate in Andaman Flysch and very low in valleys of Andaman Flysch formations. The study further revealed that the weathered and fractured volcanics of Ophiolite groups of rocks and sandstone that occur in the Andaman Flysch formations constitute the productive water bearing zones categorized as good groundwater potential zone. Based on the geoelectrical parameters, viz., thickness of layers and the layer resistivity values, a groundwater potential map was prepared, in which good, moderate, and poor groundwater zones were demarcated. Further, numerical, spatial and litho-geoelectric models of resistivity were analyzed in terms of groundwater potential and these models have thus enabled to prepare a comprehensive groundwater development and management plans proving its efficacy in this art of exploratory investigations.  相似文献   

5.
The lateritic weathering crusts exposed in mainland Greece were developed on ophiolitic ultramafic lithologies during lower Cretaceous times. The lateritic profile consists of four zones: bedrock, saprolite clay (nontronite) and goethitic. The profiles show large variations in thickness, continuity, mineralogy and chemical characteristics. They are broadly similar to clay nickel laterite deposits. The uppermost gravelly ferruginous sector was eroded and the material reworked and redeposited partly on the lateritic crust. Silcrete layers, characteristic of groundwater silcretes, were formed into the clay and goethitic zones. Significant supergene nickel enrichments occur in the clay and saprolite zones, indicating that water moved downward to a very low water table. The structure and mineralogy of the weathering crusts indicates that environmental conditions were likely to have been dominated by alternating wet and dry periods.  相似文献   

6.
Siliyin spring is one of the many natural fresh water springs in the Western Desert of Egypt. It is located at the central part of El-Fayoum Delta, which is a potential place for urban developments and touristic activities. Integrated geoelectrical survey was conducted to facilitate mapping the groundwater resources and the shallow subsurface structures in the area. Twenty-eight transient electromagnetic (TEM) soundings, three vertical electrical soundings (VES) and three electrical resistivity tomography (ERT) profiles were carried out around the Siliyin spring location. The dense cultivation, the rugged topography and the existence of infra structure in the area hindered acquiring more data. The TEM data were inverted jointly with the VES and ERT, and constrained by available geological information. Based on the inversion results, a set of geoelectrical cross-sections have been constructed. The shallow sand to sandy clay layer that forms the shallow aquifer has been completely mapped underneath and around the spring area. Flowing of water from the Siliyin spring is interconnected with the lateral lithological changes from clay to sand soil. Exploration of the extension of Siliyin spring zone is recommended. The interpretation emphasizes the importance of integrating the geoelectrical survey with the available geological information to obtain useful, cheap and fast lithological and structural subsurface information.  相似文献   

7.
地下水蒸发是旱区地下水均衡计算中重要的排泄项之一。由于包气带水分运移高度非线性且大气—地表界面动力学过程复杂,估算潜水蒸发量一直是地下水资源评价的难题之一。利用内蒙古乌审旗河南乡均衡试验场E601型蒸渗仪,建立了毛乌素沙地水面蒸发及4种典型岩性(风化砂岩K1、萨拉乌苏组砂Qpal+l、砂质壤土Qhl、风积沙Qheol)的饱和土蒸发原位试验,结合长期观测获取的大量数据,开展了地下水蒸发与水面蒸发、埋深的关系和地下水蒸发量计算方法研究。结果表明:(1)4种典型岩性(风化砂岩、萨拉乌苏组砂、砂质壤土、风积沙)饱和蒸发量与水面蒸发量比值分别为0.60,0.77,0.47,0.88,表明不同岩性的饱和裸土的蒸发强度不等于自由水面的蒸发强度;实际计算裸土蒸发强度时,不能以自由水面蒸发强度作为参考点,如果运用,必须校正。(2)利用蒸渗仪观测数据和土壤水运动方程稳态解析解,获得4种典型岩性(风化砂岩、萨拉乌苏组砂、砂质壤土、风积沙)潜水稳定蒸发计算的关键经验系数c,分别为628932.63,165058.71,48948.21,1525104.031 m?2。(3)利用稳定蒸发公式确定鄂尔多斯盆地风沙滩区四种典型包气带岩性(风化砂岩、萨拉乌苏组砂、砂质壤土、风积沙)潜水极限蒸发深度约为60 cm,结果得到了室内非稳态蒸发试验的佐证,为研究区水资源评价提供了重要的参数依据。  相似文献   

8.
Geoelectrical survey was carried out in the western delta region of River Vasista Godavari, Andhra Pradesh, India, for delineation of groundwater prospective zones due to acute shortage of water supply for various purposes. Forty-six vertical electrical soundings (VES) were done, employing the Schlumberger configuration with a maximum AB/2 of 160 m. The interpreted results of VES show four to five layers with variable thicknesses, such as topsoil zone (1.5–3 m), clay zone (0.84–32 m), finer sand zone (2–72 m), medium to coarse sand zone (4 to 28.8 m) and clay zone (1.2–∞ m), indicating a multi-aquifer system. These results are corroborated with the known lithologs of the study area. Further, the resistivity is also compared with electrical conductivity (EC) of groundwater observed nearby shallow wells representing buried channel (BC), flood plain (FP) and coastal (C) zones, which indicate slightly brackish to brackish water (EC: 1470–6010 µS/cm), whereas the groundwater observed from deep wells shows the fresh (EC: 726–1380 µS/cm), fresh to brackish (EC: 1010 to 3250 µS/cm), and brackish water (EC: 3020 to 4170 µS/cm) located in BC, FP and C zones, respectively. This survey reveals the prospective aquifer zones with potable water at VES locations of 4–6, 8, 10, 11, 14, 16–28, 33–36, 39 and 42–44, where the resistivity values vary from 10 to 40 Ω m. The slightly brackish and brackish water zones are also observed from the resistivity of less than 10 Ω m at shallow depth in BC (VES-22, 37, 38 and 46), FP (VES-1, 2, 7, 29, 30 and 40) and C (VES-3, 4, 9, 12, 13, 15, 31, 32, 41 and 45) zones. As a result, the present investigation has delineated the freshwater zones at shallow (<?12 m) and also at deeper depths (30–45 m) as prospective areas, where BC zone occurs. Freshwater pockets also identified in FP (VES-8 and 39) and C (VES-11, 14 and 15) zones. Thus, this study helps to solve the drinking and irrigation water problems.  相似文献   

9.
The objective of this study was to assess the subsurface strata and groundwater situation of Olomoro, Nigeria using borehole logging and electrical resistivity techniques. The borehole logging consisting of resistivity and spontaneous potential logs were conducted by using the Johnson Keck logger on a drilled well in the study area. The electrical resistivity survey involving 17 vertical electrical soundings (VES) with a maximum current electrode spacing of 100 to 150 m was conducted using the Schlumberger electrode configuration. Analysis of the well cuttings revealed that the lithology of the subsurface consist of topsoil, clay, very fine sand, medium grain sand, coarse sand and very coarse sand. Results of the downhole logging also revealed that the mean electrical conductivity and the total dissolved solid of the groundwater was obtained as 390 μS/cm and 245 mg/cm3 respectively. These values are within the acceptable limit set by the Standard Organization of Nigeria (SON) for drinking water. The result of the vertical electrical sounding interpreted using the computer iterative modeling revealed the presence of four to five geoelectric layers which showed a close correlation with result from the lithology and downhole logging. Results further showed that the resistivity of the subsurface aquifer ranged between 1584 and 5420 Ωm while the aquifer depths varied between 27.8 and 39.3 m. Groundwater development of the area is suggested using the depth and resistivity maps provided in this study.  相似文献   

10.
A large number of valleys and basin systems are present in the northwestern part of the Himalayas in Pakistan which form significant aquifers in the region. Hydrogeophysical investigations in the western part of Nowshera District, a part of the intermontane Peshawar basin, were undertaken to help to determine the availability of groundwater resources in the region. Thirty vertical electrical resistivity soundings (VES) were acquired using a Schlumberger expanding array configuration with a maximum current electrode spacing (AB/2) of 150 m in delineating the groundwater potential in the study area. The results of the interpreted VES data using a combination of curve matching technique and computer iterative modeling methods suggest that the area is underlain by 3 to 5 geo-electric layers. The interpretation results showed that the geo-electrical succession consists of alluvium comprising of alternating layers of clay, silty clay, fine to coarse sands, sand with gravels and gravels of variable thickness. High subsurface resistivity values are correlated with gravel–sand units and low resistivity values with the presence of clays and silts. The modeled VES results were correlated with the pumping tests results and lithological logs of the existing wells. The pumping test suggests the transmissivity of the aquifer sediments is variable corresponding to different sediments within the area. The gravel–sand intervals having high resistivity value show high transmissivity values, whereas clay–silt sediments show low transmissivities. It is concluded that majority of the high resistive gravel–sand sediments belong to an alluvial fan environment. These gravel–sand zones are promising zones for groundwater abstraction which are concentrated in the central part of the study area.  相似文献   

11.
The integrated geophysical interpretation for the different geophysical tools such as resistivity and gravity is usually used to define the structural elements, stratigraphic units, groundwater potentiality, and depth to the basement rocks. In the present work, gravity and resistivity data were utilized for detecting the groundwater aquifer and structural elements, as well as the upper and lower surfaces of the subsurface basaltic sheet in an area located at the eastern side of Ismailia Canal, northeastern Greater Cairo, Egypt. Two hundred and ten gravity stations were measured using an Autograv instrument through a grid pattern of 50?×?50 m. The different required corrections were carried out, such as drift, elevation, tide, and latitude corrections. The final corrected data represented by the Bouguer anomaly map were filtered using high- and low-pass filters into regional and residual gravity anomaly maps. The resulting residual gravity anomaly map was used for gravity modeling to calculate the depths to the upper and lower surfaces of the basaltic sheet. The resulting gravity models indicated that the depths to the upper surface of the basaltic sheet are ranged between 26 and 314 m, where the shallower depths were found around the southern and eastern parts. The depths to the lower surface of the basaltic sheet are varied from 86 to 338 m, and the thickness of the basaltic sheet is ranged from 24 to 127 m, where the biggest thicknesses were found around the southern and northern parts of the study area. Forty-two vertical electrical soundings (VES) were carried out using Schlumberger configuration with AB/2 spacings ranged from 1.5 to 500 m. 1D quantitative interpretation was carried out through manual and analytical interpretations. The VES data were also inverted assuming a 3D resistivity distribution. The results from the 3D resistivity inversion indicated that the subsurface section consists of sand, sandstone, and sandy–clays of Miocene deposits overlying the basalts. Such basaltic features (of Oligocene age) are underlain by Gabal Ahmar Formation of Oligocene deposits, which are composed of sand and sandstone. Therefore, two aquifers were deduced in the area. The first is the Miocene aquifer (shallower) and the other is the Oligocene aquifer (deeper).  相似文献   

12.
The city of Burdur, which is built on an alluvium aquifer, is located in one of the most seismically active zones in southwestern Turkey. The soil properties in the study site are characterized by unconsolidated and water-saturated sediments including silty, clayey and sandy units, and shallow groundwater level is the other characteristic of the site. Thus, the city is under soil liquefaction risk during a large earthquake. A resistivity survey including 189 vertical electrical sounding (VES) measurements was carried out in 2000 as part of a multi-disciplinary project aiming to investigate settlement properties in Burdur city and its vicinity. In the present study, the VES data acquired by using a Schlumberger array were re-processed with 1D and 2D inversion techniques to determine liquefaction potential in the study site. The results of some 1D interpretations were compared to the data from several wells drilled during the project. Also, the groundwater level map that was previously obtained by hydrological studies was extended toward north by using the resistivity data. 2D least-squares inversions were performed along nine VES profiles. This provided very useful information on vertical and horizontal extends of geologic units and water content in the subsurface. The study area is characterized by low resistivity distribution (<150 Ωm) originating from high fluid content in the subsurface. Lower resistivity (3–30 Ωm) is associated with the Quaternary and the Tertiary lacustrine sediments while relatively high resistivity (40–150 Ωm) is related to the Quaternary alluvial cone deposits. This study has also shown that the resistivity measurements are useful in the estimation of liquefaction risk in a site by providing information on the groundwater level and the fluid content in the subsurface. Based on this, we obtained a liquefaction hazard map for the study area. The liquefaction potential was classified by considering the resistivity distributions from 2D inversion of the VES profiles, the types of the sediments and the extended groundwater level map. According to this map, the study area was characterized by high liquefaction hazard risk.  相似文献   

13.
The use of resistivity sounding and two-dimensional (2-D) resistivity imaging was investigated with the aim of delineating and estimating the groundwater potential in Keffi area. Rock types identified are mainly gneisses and granites. Twenty-five resistivity soundings employing the Schlumberger electrode array were conducted across the area. Resistivity sounding data obtained were interpreted using partial curve matching approach and 1-D inversion algorithm, RESIST version 1.0. The 2-D resistivity imaging was also carried out along two traverses using dipole–dipole array, and the data obtained were subjected to finite element method modeling using DIPRO inversion algorithm to produce a two-dimensional subsurface geological model. Interpretation of results showed three to four geoelectrical layers. Layer thickness values were generally less than 2 m for collapsed zone, and ranged from 5 to 30 m for weathered bedrock (saprolite). Two major aquifer units, namely weathered bedrock (saprolite) aquifer and fractured bedrock (saprock) aquifer, have been delineated with the latter usually occurring beneath the former in most areas. Aquifer potentials in the area were estimated using simple schemes that involved the use of three geoelectrical parameters, namely: depth to fresh bedrock, weathered bedrock (saprolite) resistivity and fractured bedrock (saprock) resistivity. The assessment delineated the area into prospective high, medium and low groundwater potential zones.  相似文献   

14.
RON GOLDBERY 《Sedimentology》1979,26(2):229-251
Petrographical and mineralogical studies of the Lower Jurassic sequence exposed at Makhtesh Ramon, have shown the domination of a lateritic suite of epiclastic sediments of pisolite conglomerate and laterite arenite composition. Their subsequent modification by epigenetic processes of chemical weathering has given rise to the formation of flint clay, high alumina flint clay, laterite and mottled and variegated claystone. Within the Nahal Ardon area, both the transported laterite accumulates and the autochthonous lithologies occur interbedded within the same section. In all, a total of ten lithofacies have been defined and mapping of the various units, grouped into allochthonous and autochthonous classes, has established the existence of lateral facies changes between Nahal Ardon, where the sequence rests on a broad undulatory Triassic basement, and the zone to the west where it occurs as infillings of Triassic solution cavities, sink holes and irregular depressions. Vertical profile studies of the lithofacies indicate that the vertical range of ground water movements increased westwards from Nahal Ardon and resulted in the transported laterite accumulates being subjected to varying degrees of chemical weathering. The observed lateral facies changes are a direct consequence of this. Within the ‘karstic’ zone, the laterite accumulates in addition to the overlying younger carbonate lithologies have been converted to flint clay and demonstrate the intraformational genesis of the flint clay, whereby vertical ground water movements are related to recharge of aquifer zones within the underlying Triassic Mohilla Formation.  相似文献   

15.
Twenty seven vertical electrical sounding (VES) profiles surrounding four known traverses were obtained in Ngor-Okpala local government area of Imo state to examine the subsurface geomaterials and the associated groundwater potential. The VES data, constrained by borehole data, provided useful information about the subsurface hydrogeologic and lithologic conditions. From the validated interpretation, the area assessed has loamy soil, medium grained sands, well-sorted medium-grained/gravelly sands and river sand as the lithologic succession from top to the bottom of the depth penetrated. The aquifers in the area were found in the medium-grained sands and well-sorted medium-coarse-grained sands. The aquifer depth for all-season groundwater that would be devoid of draw-down can be found at a depth range of 42–50 m. The resistivity maps of selected depths exhibit sharp resistivity changes at depth due mainly to undulating subsurface topography. A map of the distribution of the kσ-values shows that good quality groundwater can be found in most parts of the area.  相似文献   

16.
Vertical electrical sounding (VES) was carried out in the east of the River Nile. The main objectives of the resistivity survey are to determine the types and thicknesses of sedimentary units in the area, to define the contact separating the sediments from the crystalline basement complex, and to determine the structural features of the subsurface formations. Several local depressions, whose maximum depth to the Imsement surface is about 160 m, are revealed as an outcome of the VES method, and suggested to have been infilled with undifferentiated units of the Nubian Group in particular Omdurman Formation. Thus, a depth to the basement complex is calculated and the associated structural map of the east of the River Nile is drawn. The map is useful for the groundwater drilling, as far as the presence or absence of the aquifer is concerned.  相似文献   

17.
The use of wastewater for irrigation in sandy soil increases the pollution risk of the soil and may infiltrate to the shallow groundwater aquifer. In such environment, some important parameters need to be obtained for monitoring the wastewater in the unsaturated zone over the aquifer. These parameters include clay content, heterogeneities of the upper soils, depth to the aquifer and the variations of groundwater quality. In the present work, the efficiency of DC resistivity method in forms of 1-D and 2-D measurements was studied for wastewater monitoring in the Gabal el Asfar farm, northeast of Cairo, Egypt. Forty-one Schlumberger soundings (VES) were performed then followed by three pole-dipole 2-D profiles along some considered regions within the area. The resistivity measurements were integrated with the boreholes, hydrogeological and hydrochemical (surface and groundwater samples) information to draw a clear picture for the subsurface conditions. The obtained results were presented as cross sections and 3-D visualization to trace the clay intercalations within the unsaturated zone. In addition, a vulnerability map was created using the obtained results from 1-D Schlumberger survey and confirmed with the 2-D resistivity profiling. The obtained results have shown that the 2-D resistivity imaging technique is a powerful tool for mapping the small-scale variability within the unsaturated zone and the wastewater infiltration. However, limitations of resistivity techniques were observed in the area with limited resistivity contrast such as thin clay layers with brackish water background. Under that condition, the measured pattern of resistivity distributions depends on the applied electrode array, electrode spacing and using the available geological information during the inversion process.  相似文献   

18.
Vertical electrical sounding (VES), employing a Schlumberger electrode configuration, was used to investigate the sediments and aquifer repositories in Itu Local Government Area of Akwa Ibom state, southern Nigeria. This was done in sixteen (16) locations/communities with the maximum current electrode spread ranging between 800–1000m. The field data were interpreted using forward and iterative least square inversion modeling, which gives a resolution with 3–5 geoelectric layers. The observed frequencies in curve types include 31.25% of AKH, 18.8% of AAK and HK and 6.25% of K, QHK, AKH, KA and KHQ, respectively. These sets of curves show a wide range of variabilities in resistivities between and within the layers penetrated by current. The presence of K and H curve types in the study area indicates the alteration of the geomaterials with limited hydrologic significance to the prolific groundwater repository. A correlation of the constrained nearby borehole lithology logs with the VES results shows that the layers were all sandy formations (fine and well sorted sands to gravelly sands or medium to coarse-grained sands as described by nearby lithology logs) with some wide ranges of electrical resistivity values and thicknesses caused by electrostratigraphic inhomogeneity. The geologic topsoil (motley topsoil) is generally porous and permeable and as such the longitudinal conductance (S) values for the covering/protective layer is generally less than unity of Siemens (S < 1Ω?1), the value considered for efficient protection of the underlying aquifers by the topmost and overlying layer. The spatial orientations and the leveling patterns of the most economically viable potential groundwater repository within the maximum current electrode separations has been delineated in 2-D and 3-D contoured maps. The estimated depth range for the desired groundwater repository is 32.6–113.1m and its average depth value is 74.30m. The thickness of this layer ranges from 27.9–103m while its average depth has been evaluated to be 63.02m. Also, its resistivity range and average value have been estimated to be 507–5612m and 3365.125Ωm  相似文献   

19.
In the Bicholime, Goa, there is an iron-ore mine surrounded by villages and small towns. Exploitation of such an enormous amount of iron ore may disturb the local groundwater table, thereby causing groundwater depletion. However, these effects are dependent mainly on the geological formations in the region and the mining method. The effects of Bicholime mining on the surrounding groundwater resources and subsurface strata conditions are the main objective of this study. For this purpose, ground penetrating radar surveys were carried out to study the possible effects of mining on the hydrological regime of this open-pit mine, and the subsurface conditions in the Bicholime opencast iron-ore mine, Goa. The results of these surveys show that laterite layers exist from the surface to depths varying from 5 to 22 m at all study locations in the mining area, and in most places clay layers exist, except for the GPR section along the profiles DD1 and EE1 in the village at depths of 8-22 m. Due to the presence of impervious clay layers, mining and dewatering in the leasehold areas will most likely not affect the surrounding hydrological regime of this mining area. It is concluded that no hydrological connection exists between the open pits and the surrounding villages, so that sufficient groundwater is available in the village area, in spite of the enormous extraction of iron ore from the underground.  相似文献   

20.
Integrated geoelectrical and hydrochemical surveys were used to investigate and delineate different types of groundwater in the Kuala Selangor alluvial aquifer. Previous hydrogeological borehole investigation showed that this aquifer contains several types of groundwater in relation to its salinity. The high salinity of the groundwater in some areas is believed to be due to either saltwater intrusion from the nearby sea or river infiltration during high tide season. The vertical electrical sounding (VES) method was employed to study and map the subsurface variation of resistivity in the area. For each sounding measurement, a total spread length of 300 m was obtained with a vertical depth penetration of about 60 to 75 m. Chemical analysis of the groundwater samples taken from both shallow and deep boreholes was carried out for the water quality determination. A total of 45 VES stations were succesfully established along three parallel roads with a direction almost perpendicular to the coastal line. The distance between stations varies from 1 to 2 km with a maximum length of about 60 km surveyed line. Results of the vertical electrical soundings as well as the hydrochemistry of the groundwater samples show that the soil and groundwater in the study area can be grouped into fresh and brackish water zones. The subsurface resisitivity sections derived from the VES study suggest that the area is dominated by brackish soil and groundwater zones, especially in the area towards the coast. This result appears to agree well with the groundwater pumped from boreholes scattered around in the area. Water drawn from boreholes near the coast showed higher salinity compared to the water pumped from inland boreholes. Chloride values greater than 250 mg/L are considered to represent the brackish zones whilst values less than 250 mg/L represents zones of fresh soil and groundwater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号