51.
Palynological research is increasingly revealing the landscape impacts of Norse colonisation in southern Greenland. Typically, although not exclusively, these studies are from depositional environments with highly localised pollen source areas close to fjord-side centres of medieval power. In contrast, this paper presents data from Vatnahverfi, an inland district of the Eastern Settlement, and explores the emergence of a cultural landscape through three pollen sequences at variable distances from Norse farms. Two are from mires with small pollen source areas close to (< 100 m) and distant from (≥ 1500 m) probable farming activities. The other provides a more regional signal of vegetation change, albeit one located close to a Norse settlement. Landnám is marked primarily through an increase in microscopic charcoal and the appearance of pollen from Rumex acetosella, although significant differences between profiles are noted. Close to Norse ruins, pollen productivity from grassland communities increases and woodland and scrub representation declines. Further from archaeological remains, palynologically inferred human activity is primarily characterised by decreased productivity, notably declining influx from woodland and scrub species, reflecting grazing herbivores or coppicing. Abandonment of Vatnahverfi is indicated from the late 14th to early 15th century AD. 相似文献
52.
53.
In performance-based geotechnical earthquake engineering, the required degree and spatial extent of ground densification for mitigation of liquefaction beneath a structure should be determined based on the acceptable levels of performance of foundation. Currently, there is no solution for evaluation of the amount of settlement and tilt of footings constructed on a densified ground which is surrounded by a liquefiable soil. This implies the need for numerical procedures for simulation of seismic behavior of shallow foundations supported on both liquefiable and densified subsoil. In this paper, the dynamic response of shallow foundations on a densified ground is studied using a 3D fully coupled dynamic analysis. For verification of the numerical model, simulation of a series of centrifuge experiments has been carried out and the results were compared with the experimental measurements. After verification of the numerical model, a comprehensive parametric study has been performed to develop a methodology for estimating the effectiveness of subsoil densification in reducing liquefaction-induced settlement of shallow foundations. Range of problem variables were considered in a way that the possibility of bearing capacity failure is low enough. The proposed methodology can be utilized for development of a performance-based design procedure for liquefaction hazard mitigation by soil densification. 相似文献
54.
Leonidas T. Stavridis 《Geotechnical and Geological Engineering》2009,27(3):407-417
A rigid foundation of arbitrary shape resting on a stratified half space (soil), with specific geometrical and elastic properties
for its horizontal layers, is examined under the action of a vertical load placed anywhere on the foundation area. On the
basis of a purely analytical treatment of the deformability of the soil surface, i.e. without using a finite element discretization
of the layered soil mass, a general method is developed in order to determine the contact soil pressures and the resulting
settlements through an easily implemented numerical procedure. The possible presence of “inactive” foundation parts not being
in contact with the soil surface is taken into account. Parametric studies are performed showing the influence of the variability
of the soil layers, as well as of the vertical load location, on the contact pressures developed. In this context, for the
cases of a rectangular and a circular foundation the area borders for the location of a vertical load are determined, either
for the development of compressive soil pressures all over the footing (core), or for allowing the existence of some inactive
part without contact with the soil (zero contact pressure), not exceeding the half of the total foundation surface (limit
core). 相似文献
55.
Construction of a 16-m deep, 55-m wide, almost square, underground structure through 8-m of soft soils and 8-m of sandstone and siltstone led to the development of widespread settlements. The affected area extended to distances of over 200 m from the perimeter of the structure. The floor slab of the underground structure was not designed for water pressure. Thus, operation of the structure requires continuous pumping of seepage water collected at a sump located at the lowermost elevation within the structure. Subsurface investigation and monitoring data obtained over 5.75-year period following the construction of the structure indicated that the settlement resulted from consolidation of soft soils due to depressurization of an aquifer within the underlying bedrock caused by continuous dewatering needed for the operation of the structure. An analytical study was undertaken to project the long term settlement. A simple analytical model could be used to simulate the complex hydrogeological problem reasonably. The details of hydrogeologic setting, subsurface investigation and monitoring activities, and the analytical model for projecting long-term settlements are presented in this paper. 相似文献
56.
Settlement of surface structures, which is particularly a private house, due to subsoil liquefaction is not a new issue in geotechnical engineering. It has been happening during earthquakes in liquefaction-prone areas since many years ago. However, to date no reliable measure against this problem with reasonable cost has been proposed to people. In this paper, results of a series of 1-g shaking table tests which have been conducted to evaluate performance of a possible mitigation against this problem are presented. The proposed mitigation herein is installation of sheet-pile walls around the foundation. In order to reduce the cost of mitigation, sheet-piling with gap and half-length sheet-piling were examined. The experiments were conducted in different ground water levels. It is found out that installing sheet-pile walls in relatively low ground water level can stop settlement of structures completely. Sheet-piling with gaps delays initiation of settlement but it may increase the ultimate settlement of structure. In addition, it is found that formation of a water film under the building׳s foundation is the governing mechanism of post-shaking settlement of structures. 相似文献
57.
The liquefaction database describing the response of the Christchurch area in the 2010–2011 Canterbury Earthquake Sequence (CES) provides a unique basis for evaluating the regional application of various liquefaction analysis procedures, from liquefaction triggering analyses through to liquefaction vulnerability parameters. This database was used to compare the Robertson and Wride [17], Moss et al. [15] and Idriss and Boulanger [7] liquefaction triggering procedures as well as evaluate the impact of the 2014 versus 2008 Cone Penetration Test (CPT)-based liquefaction triggering procedure by Idriss and Boulanger on four liquefaction vulnerability parameters (SV1D, LPI, LPIISH and LSN), the correlation of those parameters with observed liquefaction-induced damage patterns in the CES, and the mapping of expected damage levels for 25, 100 and 500 year return period ground motions in Christchurch. The effects on SV1D, LPI, LPIISH and LSN were small relative to other sources of variability for the majority of the affected areas, particularly where liquefaction was clearly severe or clearly not. Nonetheless, considering the separation of the land damage populations as well as consistency between the events, the the IB-2008 liquefaction triggering procedures appears to give a slightly better fit to the mapped liquefaction-induced land damage for the regional prediction of liquefaction vulnerability for the Christchurch soils. The Boulanger and Idriss [1] triggering procedure produces improved agreement between the liquefaction vulnerability parameters and observations of damage for: areas south of the Central Business District (CBD) where there tends to be higher soil Fines Content (FC), and localized areas that experienced liquefaction during the smaller Magnitude (M) earthquake events. Implementation of the 2014 liquefaction triggering procedure for mapping of expected liquefaction-induced damage at 25, 100 and 500 year return period ground motions is shown to require use of representative Peak Ground Acceleration (PGA)-M values consistent with the de-aggregation of the seismic hazard. Use of equivalent magnitude-scaled PGA-M7.5 pairs, where the equivalency relates to previously published MSF relationships, with the 2014 liquefaction triggering procedure is shown to be unconservative for certain situations. 相似文献
58.
Yakov M. Reznik 《Engineering Geology》1998,50(3-4):319-327
Footing settlements depend not only on physical and mechanical properties of base soils, but also on applied load intensities and their distributions with depth, as well as on footing rigidity, shape and dimensions. An analytical expression relating rigid bearing plate and/or footing settlements to thicknesses of deformation (active) zones, which form below footing bottoms, has been previously offered by the author. The results of tests performed with 0.5, 1.0 and 4.0 m2-area square footings, constructed on undisturbed clayey soils and containing data describing active zone development, were collected from literature and analyzed. This paper presents graphical relationships between square footing settlements, active zone thicknesses and footing dimensions, which are verified by published test results performed with experimental square footings, having areas different than the ones selected for statistical analyses. 相似文献
59.
60.